1. EACOME Conference Phone System User manual G2S Series EACOME ELECTRONICS CO LTD Suite 3007 Tianxia Tower No 115 Yiyuan Road Nanshan District Shenzhen China Postcode 518052 Tel 86 755 86223352 Fax 86 755 86223522 Web http www eacome com E mail service eacome com IMPORTANT SAFETY INSTRUCTIONS When using your telephone equipment basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following e This unit is NOT waterproof DO NOT expose this unit to moisture e DO NOT expose this unit to rain e Do not use this product near water for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool e Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning e Do not use the telephone to report a gas leak in the vicinity of the leak e Use only the power cord indicated in this manual SAVE THESE INSTRUCTIONS Important Notice Under power failure conditions this appliance may not operate Please ensure that a separate telephone not dependent on local power is available for emergency use CONTENTS PARTS IS Tania 2 EUW FU a E A E E teat erotica ee ase elena 2 GI SEP Standard ACCES O E reiia cme ee ee eect ees 2 BD SAAC GS Oe E E EE A A E R een Rees 2 ELON AN ACCESS OTE ee ea ee 3 INSTALLING
2. Press the MUTE key for 5 seconds in stand by to delete all call history PSTN Using the menu The G2S feature settings can be accessed manually using the keypad and menu keys Rapid dial In on hook state See illustration below 1 Push rapid dial MEMO button Available for G2S P models and indicator LEDs turn green Use the B keys and button to navigate through various Menu Settings 2 Dial two rapid dial slot identification number and blue LEDs will keep on if dialled correctly Dial rapid dial number illustration pA Two rapid dial slot identification numbers Please note 1 Each of the two rapid dial slot identification number should be within 0 9 and the identification number should be within 0 20 2 All the rapid dial operations should be used in the on hook state Any illegal operation during the process will turn on red LEDs Illegal operation is rapid dial slot identification number is greater than 20 or rapid dial slot is non exist or no number is stored in the rapid dial slot 17 ILM PSTN 4 SPEEDIAL 12 13 Function Adjustment 1 Setthe Date Time Press key and then the screen display 1 SET DATE Then press the key to confirm and select the setting item When the item font is flashing press the key to set press MUTE key to confirm 2 Set Flash Flash Time90 100 120 180 300 500 600 900ms Press B key and then press till the scr
3. AND SELF DETECTING ssissssscesssuccesenssssissicscssssaccksvasvvvicxvvuvevniGsssiesnsssnsvansscecccsecessestasvsnusisuieevinverieuneseess 3 ASTA N a en mca taal en eat anes es aT acne tT 3 SF TEN ee era ee 4 INSTALLING DIAGRAMS AND INTERFACE SPECIFICATION sessssesssossesoesosoesososoesossesoesesosossesossesossososossosossosossososoes 4 E GEO TA EAN ores AEA A AEA E A AAAI E I EE E AN A 4 Miter Ace SREcI EA ON rea A ee 5 GETTING TO KNOW TOUR PHONE au ran nennen 6 PArS OL IE PHONE nee ne ee 6 ES BR ara facie gs eare ER NEENRES RE E E A rr rte a PER enn 7 Understanding the DIEB Ayers en 7 Keypadi Su pport for P Mode een een 8 Keypad2 uppoo Or Y Mode Venen ae 9 USING YOUR PHONE uam een aE EEREN EN REKON ee ET 10 a E cl ERTE E AA AAA A E EA A AE A E E A REN E E A E E T 10 PSTN Line Direct Dial Redial Rapid Dial Recall ssssassscsossasesesnssseevencessoaveseesssscansnsecsneseseeteveseseavesesenscononseoenhssvoneaserenonsecennyeccanavecsansesestensts 10 USB LINE Available tor Adnet ee een ee een TE Sia ESAIN 10 E LE EE A AOA A EEA EE O A E I AEE PEE A E een 11 CNI E E A E E EAE 11 MAW VO en ee aa ee ee ee een 11 FRSC crate A E E E E ccc Ua ETA ET AET EA ORTS ENT EE ES E EE A A EA EA E 11 FGA MEAE E PA IE E EAE P IOT EEA A T OAE sive esnsotuasevettnanstuiaesastatstanetasmuanaaasensainiasieteasneaariennd 11 EE I sss cea A E A N ea N A AA A A EA Rare E 11 SEIFENIMAT GI ANA TANCE oea EE a tieanaa tection pete setae ceeecccta 11 Erasing Recor
4. SM BT F Line Status COO OOOO Dynamic Information Zone LILILILILILILILILILILILILILILIL Keypadi For P Model Keypad2 For U Model RW N 5 Fra Br woe y 10 Navigate up down through displayed lists Navigate up down through displayed lists Flash feature in the call state G2S U does not support this function Rapid dial G2S U does not support this function Redial the last dialled number Recall the desired number G2S U does not support this function Dial end a call from analog line PSTN line Answer end a call from USB line Off hook On hook Display a menu of settings and options Display a menu of settings and options Choose a menu item Choose a menu item Mute the call in the call state Delete the call history in the stand by Mute the call in the call state Adjust speaker volume Browse call history Adjust speaker volume Mute both parties in the conversation but still keep the line up Mute both parties in the conversation but still keep the line up Dial pad G2S U does not support this function USING YOUR PHONE Placing a Call G2S allows you to place a call over an analog phone line Available for P model G2S allows you to place a call over a USB line Available for U
5. ay cause an echo effect e Don t put any objects within 60cm from your phone CAUTION To reduce risk of personal injury fire or damaged use only the power adaptor supplied with this product INSTALLING 1 Connect the 8 Stream cable into the EXT jack of the AC adaptor interface module and the POWER jack on the port bay of the G2S See 1 on the connection diagram 2 Connect the telephone line cable into the LINE jack on the AC adaptor interface module and a telephone wall jack See 2 on the connection diagram Available for G2S P 3 Connect the USB port of G2S to a PC through the USB cable This function is available for G2S U model 4 Connect the AC adaptor interface power cord into a standard AC power outlet See 3 on the connection diagram 5 Connect the optional extension microphones into the EXT1 and EXT2 jacks of the G2S This function is available for G2S E model When installing 2 extension microphones using 4P4C cable to connect the phone and the 4P plug of the extension microphones See 4 on the connection diagram SELF DETECTING When the conference phone has access to electricity the self detecting program will be activated The green red and blue indicator LEDs will flash sequentially The LCD will show EACOME The self detection will be finished after testing music NOTE e The G2S is properly installed for PSTN land line use if you press and hear a dial tone the displa
6. d In the state of standby MOde ssssssssscsssssesssssssssssssssssssssessssssssssnsessssssssnssssssssssnssscsessssnsessesssssssscessessssnsccessssnsnsssesssses 11 RA a ee ea nee 12 PHONE SE Ti ING eek 13 F NENON AO NEN nennen nennen anne een Te 14 Speaker Volume AO ENTER ee anne uk 14 PSTN Fash Setting And ACES ae IE 15 DONOEDESTUDIDND ie O cx careers mene errr E TE E 15 Caena ne IND ee een 15 INSTALLING EXTENSION MICROPHONE susanne ne 16 ONE YEAR LIMITED WARRANT Tue 17 PARTSLIST G2S Series Conference Phone Parts List G2S P 6 5m Length 8 Strand Cable RJ 11 Cable AC Power Cord Telephone Line Cable Documents Parts List G2S U 6 5m Length 8 Strand Cable USB Cable AC Power Cable Documents OPTIONAL ACCESSORIES 4P4C Stream Cable X2 Extension microphone up to 2 If any items are missing or damaged contact your place of purchase immediately x Never use damaged products INSTALLING AND SELF DETECTING For best performance of your conference phone avoid the following locations when selecting an installation location e Areas with high background noise The microphones might pick up these sounds and prevent the speakerphone from going into receiving mode when you finish talking e Surfaces affected by vibration e Recessed areas such as in a corner under a cupboard or next to a cabinet These locations m
7. een display 2 SET FALSH Then press key to enter the situation of setting Press to choose the wanted standard of flash At last press the key to confirm 3 Adjust the LCD Bright Press B key and then press 4 till the screen display 3 SET BRIGHT Then press l to enter the situation of the setting adjust the bright of LCD through operating at last press to confirm 4 Store and Rapid Dial Store 20 Group of Speed dial Numbers Press eland then press till the screen display 4 SPEEDIAL Then press e to confirm and select the setting item The LCD will display GROUP 01 20 Then input the double digit serial number of speed dial from 01 to 20 then input the corresponding phone number If you want to cover or re edit the existed number press the LCD will display BEGIN CANCEL choose BEGIN then press to input anew phone number If you don t want to cover or re edit the existed number choose CANCEL then press e lt gt lt JJ Speaker Volume Adjustment 1 During an active call press the volume buttons to adjust the speaker volume The speaker volume will increase from 1 to 12 The volume level will display on the LCD screen The current main volume appears on the display screen 2 The LEDs will blink green within the scope and will blink red beyond
8. model PSTN Line Direct Dial Redial Rapid Dial Recall 1 Direct Dial To obtain dial tone press C key Then dial the desired number The blue indicator LEDs always keep on 2 Redial Press the REDIAL key The last number called will be displayed and dialled 3 Rapid Dial In stand by press rapid dial MEMO key the LCD will display SPDL 01 20 Then dial two rapid dial slot identification number 4 Recall In stand by use the volume buttons to look through previously dialled numbers press REDIAL key to dial the numbers you select za The blue indicator LEDs always keep on and the LCD will display PSTN za When a call is coming press key then G2S will turn on speaker and microphones When you press key in stand by G2S will turn on microphones only after you press any number key za Press key to cancel the call in the process of dialling USB LINE Available for U U model is able to connect to PC and video conferencing system via USB providing up to 16 KHz bandwidth for speaker and microphones Make sure the PC video devices are ready when placing a call through USB line For these instructions it is assumed that the computer is turned on the VoIP software e g Skype or video conferencing software is running and the ll y G2S is connected to the computer via the USBcable 1 USB marked on the left side of the phone console is used to connect to the USB port of PC or video teleconferencing b
9. phone position is shown as in the figure below 4 There are MUTE button and status LEDs on the extension microphones x Green LEDs indicate that microphone is on work x Red LEDs indicate that microphone is muted Mute button and status LED Extension microphone NOTE You should plug and pull the cable to extension microphone s 4P4C jacks while power supply is disconnected to ensure microphone work well 16
10. the scope when adjusting the volume Special settings G2S provides PA and 0 settings for PA system applications G2S will turn off the internal microphones and local speaker when the volume level is PA setting G2S will turn off local speaker when the volume level is 0 setting 14 PSTN Flash Setting and Access 1 To access PSTN Flash Setting press E and use Selection Keys to select Flash Press e 2 The LCD will show flash time type then select the type you want 3 Press FLASH button to perform FLASH function G2S P Model Series x By default Flash time is set to 300ms Do Not Disturb DND In stand by long press the FLASH button for 5 seconds to enter the DND status The LCD will display DND When you have an incoming call the red indicator LEDs will blink and you cannot hear ringing tone NT LU ULI za The green indicator LEDs will blink when setting DND Cancelling the DND Long press the FLASH button for 5 seconds the green indicator LEDs will blink and DND on the LCD will disappear amp After power failure the setting will restore to default 15 INSTALLING EXTENSION MICROPHONES 1 Plug the optional extension microphones into the EXT1 and EXT2 jacks ofthe conference phone G2S series See 4 amp 5 on the connection diagram 2 Plug the AC adaptor power into the AC jack 3 To pick up well please speak facing the microphone The inner micro
11. y USB cable It will take 5 10 seconds to install the driver automatically for the first setup 2 Press key to open G2S speaker and microphones to enjoy the HD voice USB VoIP conversation The blue indicator LEDs always keep on The LCD screen will display USB 3 Press in the call state to exit this USB VoIP call 10 Answering a Call The indicator LEDs will blink red when the phone rings Press to answer an incoming call from analog phone line The LCD will display PSTN Call Mute To mute a call press the MUTE button during a call to turn the microphone off The red LEDs will keep on amp To release mute press the mute button again Call hold To place a call on hold press the HOLD key Both the microphones and the speaker are turned off The blue LEDs will keep on Redial Press the REDIAL key The last number called will be displayed and dialled Recall In stand by use the volume buttons to look through previously dialled numbers press REDIAL key to dial the numbers you select Ending a Call ee To end a PSTN USB call in the call state press the key Searching For an Entry 1 Press gt key the LCD will display dialled numbers for latest 20 entries 2 Press lt key the LCD will display incoming numbers for latest 20 entries Erasing Record in the state of standby mode OC PHONE SETTING tom Ap
12. y will show PSTN Dialing Otherwise recheck all the installation steps e Inthe event of a power outage the G2S will not be able to make and receive calls INSTALLING DIAGRAMS AND INTERFACE SPECIFICATION Connection Diagram 1 6 5m length 8 Strand Cable 2 Telephone Line Cable For P mode 3 Power Cord 4 Extension Microphone 1 Optional 5 Extension Microphone optional 6 Extension Microphone optional Cable 7 USB Cable for U model x Feature annotation is the sum of various models not just the corresponding to a specific model of products Interface Specification POWER Power jack on the port bay of the G2S LINE Telephone line jack on the AC adaptor Interface module EXT1 EXT1 jack of extension microphone EXT2 EXT2 jack of extension microphone EXT EXT jack on the AC adaptor Interface module USB USB port connect to PC GETTING TO KNOW YOUR PHONE Parts ofthe Phone 1 LCD 2 Microphones 3 Keypad 4 Speaker LED Indicators Blue Blinking blue Conference call is on hold Red Blinking Red A call is incoming Green Blinking green Setting is in progress Conference call is in progress Conference call is muted Understanding the Display ou 20 00 00 v To a l OM Ol 00 000 our gt Time amp Call History MON TUE WED THU FRI SAT SUN F Week PSTN USB REC LINE1 LINE2 G
Download Pdf Manuals
Related Search
Related Contents
Mode d-emploi 2011 Cl- Francas La chapelle Thouarault MODEL : LK-P20B Ibico pouchMaster Pro deutsch - Fakultät für Wirtschaftswissenschaften MACHINE A GRAVER A MOUSSE GRAV`CI 3 Samsung BD-F6900 Priručnik za korisnike Stratégie média et média-planning mode d`emploi Vigo VG07019 Installation Guide 集中潤滑システムの概要_LS-0001-JA Copyright © All rights reserved.