Home

User`s Manual USA

image

Contents

1. Stand cover Hexagonal wrench 16 4 Place the foam padding on the footplate of the InBody370 Cover the InBody370 with the polyethylene foam cover then lower the upper part gt Polyethylene foam cover Foam padding A Caution Always use the protective packing materials provided by BIOSPACE when repacking 5 Put the InBody into the packing box Place the packing pad over the equipment and tape up the packing box Packing pads C Transportation and Storage Environment The InBody370 should be transported or stored under the following conditions Temperature range 4 158 F 20 70 C Relative humidity 10 95 RH No Condensation Atmospheric pressure 50 106kPa 17 IV Frequently Asked Questions FAQ Even if no problems arise from the equipment users may still have many questions especially regarding clinical procedures Few common questions and answers are listed below If your questions are not answered here please contact BIOSPACE A Regarding the InBody Question Answer My InBody370 does not Insert the power plug completely into a grounded 3 socket outlet turn on Grounded 3 socket outlet When using a power surge protector the equipment may not power on if the power switch on the power surge protector is turned off Check the power surge protector which the power plug is connected to Power surge protector power switch The
2. D Initial Setup E Connecting Printer and Stadiometer F Maintenance II InBody Test A Precautionary Steps B Test Instructions C Test Posture HI Transportation and Storage A Cautions during Transportation B Repacking Instructions C Transportation and Storage Environment IV Frequently Asked Questions FAQ A Regarding the InBody B Regarding the InBody Test V Others A Exterior and Functions B Safety Information C Classification D Specifications On ta A 10 12 13 14 15 16 16 17 18 20 21 24 25 25 4 I InBody370 Installation A Product Components The InBody370 consists of the following components Please make sure all of the following components are present Please inspect each component of the InBody370 for defects prior to installation InBody370 Adapter DC 12V 3 4A 1 EA Power cord 1 EA O User s Manual 1EA Hexagonal Wrench 1 EA Joint Screw 1 EA Upper part Hand electrodes Footplate B Operating Environment Please make sure that the environment is adequate for the InBody370 installation This equipment is designed for indoor use If installing outdoors the following requirements must be fulfilled Temperature range 50 104 F 10 40 C Relative humidity 30 75 RH Atmospheric pressure 70 106kPa C Installation Instructions 1 Open the packing box of the InBody370 and remove the packing
3. Maintain proper posture to take the test Refer to C Test Posture for the proper posture InBody Keep your arms straight and away from the torso 5 The InBody Test begins 115 4 ths 25 6 ws 9 8 us 14 6 When the test is completed the results will be shown on screen 130 3 ms 43 2 its 48 0 ts C Test Posture The examinee must maintain proper posture to have accurate test results The test will proceed when there is good electrical contact Your arms must not touch the sides of your body Keep the arms straight The thighs should not touch Hold the hand electrode so that the 4 fingers wrap the surface of the bottom hand electrode and place the thumb on the oval electrode IL Place the heels on the rear sole Step on the footplate barefoot electrodes 15 Ill Transportation and Storage A Cautions during Transportation When transporting have two people keep the InBody370 parallel to the ground B Repacking Instructions Once the InBody370 is installed avoid transporting the equipment If it must be transported repack it in the following sequence 1 Turn off the InBody370 2 Separate the connected adapter cords and cables from the equipment 3 Remove the stand cover then remove the joint screw located on the InBody370 joints by rotating the hexagonal wrench counter clockwise
4. Control Basal Metabolic Rate Impedance at each segment frequency Indications for use For use only in healthy subjects for Measurement of Estimated Skeletal Muscle Mass Extra Cellular Water ECW Intra Cellular Water ICW Total Body Water TBW ECW TBW Body Fat Mass Percentage of Body Fat PBF Body Lean Dry Lean Metabolic Rates Basal Metabolic Rates Segmental Lean Mass Actual Weight Body Mass Index BMI and Impedance Values Height Optional Equipment Stadiometers from BIOSPACE Custom Logo Name Address and Contact Information can be shown on the InBody Results Sheet Digital Results LCD Monitor Data management software Lookin Body Results Sheet InBody Results Sheet Voice Guidance Provides audible indication for test in progress test complete and successfully saved settings changes Test results can be saved if the member ID is utilized The InBody can save up to 100 000 Database results SETUP Configure settings and manage data USB Thumb Drive Copy backup si restore the InBody370 data can be viewed on the Computer software Program Lookin Body 25 Applied Rating Current 2501 A Adapter Power Input AC 100 240V 50 60Hz 1 2A Power Output DC 12V 3 4A Display Type 800 x 480 7inch Color TFT LCD Internal Interface Touch screen External Interface RS 232C 1EA USB HOST 1EA USB SLAVE 1EA Compatible Printer Laser Inkjet Printers A list of printers compatible w
5. equipment about once every week Be careful not to scratch the LCD screen When storing the InBody370 remove the batteries repackage and place the equipment on a leveled surface H InBody Test A Precautionary Steps A Warning Individuals with medical implant devices such as pacemakers or essential support devices such as patient monitoring systems must not use this equipment Safe low level currents will flow through the body during the test which may cause malfunctioning of the device or endanger lives Bioelectrical Impedance Analysis BIA uses safe low level currents which are not harmful to the body However we do not recommend pregnant women test Children and people with limited mobility should be supervised or assisted when attempting to test on the InBody After an individual with any kind of contagious disease or infection tests on the InBody use an InBody Tissue to clean the equipment AN Caution Stand upright for about 5 minutes before testing Taking the test immediately after lying in bed or sitting for a long period of time might result in a slight change in the test results This is because body water tends to move to the lower body as soon as the person stands or gets up Do not eat before testing In cases where the examinee has already eaten the test should be put off for at least two hours after the meal This is because food mass is included in the examinee s weight and thus may result
6. in measurement errors Use the bathroom before testing Waste is not included in the body s compositional elements but the volume of urine and excrement is included in the weight measurement affecting accuracy of the test results Do not exercise before testing Strenuous exercise or sharp movements can cause temporary changes in body composition Even light exercise can change your body composition temporarily Take the test in the morning if possible Body water tends to gravitate towards the lower body throughout the day affecting accuracy of the test results Thoroughly wipe the palms and soles with the InBody Tissue before testing Testing may be difficult if the examinee s palms and soles are too dry or if the examinee has too many calluses For inquires regarding the InBody Tissue please contact BIOSPACE Avoid contact with the examinee during testing Contact may lead to interference affecting test results 13 B Test Instructions 1 Step on the footplate when the screen below is shown DATABASE CC SETUP 2 Weight measurement begins Please press Enter to confirm your ID In Body If incorrect press Edit Weight 130 3 Weight measurement is completed 3 Input personal information and confirm your personal profile InBody ID Jane Doe Height 5ft 1 8in Age F 51 Please press Enter to confirm your ID if incorrect press Edit Gender Female Enter 4
7. not spray any liquid substance directly onto the device Ne pulverisez aucune substances liquids directement sur l appareil Spr hen Sie keine fl ssigen Substanzen direkt auf das Gerat CAUTION No excessive force on shoulder joint Ne pas appliquer de force excessive sur les bars articul s Keine berm ige Kraft auf das Ger t anweden CAUTION near the hinge below To avoid inquires while raising the stand of the InBody please do not place hands or any other body parts a 12V 34A USB er USB a 6 0 23 B Safety Information Indicators 9 pin serial port Female RS 232C GI a USB port Safety Symbols Dangerous High Voltage Warning Caution Pl gt 24 BF Type Equipment OCO 12V 34A Adapter Power On eo O Power Off Follow instructions for use Suivez les instructions d utilisation WARNING Electric shock hazard do not dismantle Dismantling will void the warranty AVERTISSEMENT Risque de choc lectrique ne pas d monter Le d montage annulera la garantie D DANGER Do not use this equipment with electrical medical device such as a pacemaker Ne pas utiliser cet quipement avec des appareils m dicaux lectriques comme un stimulateur cardiaque Gu CAU
8. pads Then take the InBody370 out of the box A Caution If you have any problems installing your InBody370 please contact BIOSPACE for assistance Do not transport the equipment by holding the screen portion or the joints of the hand electrodes Keep the packing materials provided for repacking the equipment in the future Other wastes should be disposed of according to relevant laws and regulations 2 After raising the upper part of the InBody370 all the way remove the polyethylene foam cover Then remove the foam padding from the footplate A Caution Using the InBody370 on carpet may cause static electricity which could damage the equipment If installing the InBody370 on carpet is unavoidable please use an antistatic mat Install the InBody370 on a leveled non vibrating surface Installing the equipment on an uneven surface may cause the examinee to fall down Test results may also be inaccurate Never clean the hand and foot electrodes with liquid spray or detergent directly The equipment may corrode and or malfunction if the liquid or detergent leaks inside Use the InBody Tissue when cleaning the InBody370 For inquires regarding the InBody Tissue Please contact BIOSPACE 3 Raise the stand cover to reveal the joint screw Tighten the joint screw connecting the upper part and footplate with a hexagonal wrench After the upper part of the InBody370 is secured in place cover the Joint screw with the sta
9. to the scale which measures the examinee s weight O Level indicator Indicates the current horizontal level of the InBody370 Stand cover Used to cover the joint screw O Joint screw Secures the upper part to the foot plate Leveling screws Used for adjusting the horizontal level of the equipment 3 Rear Panel 0 Speaker Provides audible indication for test in progress test complete and successfully saved setting changes Rear cover Designed to be opened only by BIOSPACE service personnel for checking internal circuits etc Power switch Used for turning on off the equipment Power input Port Used for connecting to the power adapter Always use the specified adapter provided by BIOSPACE as it is a part of the InBody370 Using other adapters may result in malfunction of the InBody370 0 9 pin serial port Female RS 232C Used for connecting the InBody370 to Lookin Body120 installed on the computer The InBody370 can be connected to Lookin Body120 installed on a computer using the USB SLAVE port USB HOST port Used for connecting to a printer or a USB Thumb Drive USB SLAVE port Used for connecting the InBody370 to Lookin Body120 installed on a computer The InBody370 can be connected to Lookin Body120 installed on a computer using the 9 pin serial port InBody 370 INPUT DC 12V 3 4A AC DC Ada
10. Except for the weight jewelry does not effect the body composition analysis as the contact point with the InBody120 are hands and feet I have limited mobility It is impossible to test if an individual cannot maintain contact with the and cannot maintain proper hand or foot electrodes BIOSPACE has a line of products that conduct body posture for the InBody Test composition analysis on bed ridden examinees that allow the patients to How can I still be tested stay in bed For more information please contact BIOSPACE e Is the electric current harmful to the body The physiological electric impedance method uses safe low level currents that is not harmful to the body The safety of the InBody has been tested and proven The InBody products have been approved for medical use by the CE and all over the world Many medical institutions around the world are actively using the InBody How often should I take the InBody Test Individuals who are undergoing any programs that may affect their body composition are strongly recommended to have the InBody Test done every two to four weeks Consistent testing will allow individuals to track and monitor their progress over time What are the precautionary steps to ensure accuracy of the InBody Test Please refer to A Precautionary Steps in section II InBody Test in this User s Manual V Others The InBody370 is manufactured according to the quality ma
11. InBody370 User s Manual Please note the important information below before reading this manual A Warning Failure to comply with safety warnings and regulations can cause serious injury or death A Caution Failure to comply with safety cautions and regulations can cause injury or property damage For any problems with the InBody370 or any clinical questions contact Biospace Inc 13850 Cerritos Corporate Dr Unit C Cerritos CA 90703 USA TEL 1 323 932 6503 FAX 1 323 952 5009 Website http www biospaceamerica com E mail USA biospaceamerica com 1996 Biospace Co Ltd All rights reserved Reproduction adaptation or translation of this manual is prohibited without prior written consent from Biospace Co Ltd under the copyright laws This manual might have typographical errors and its content can be changed without prior notice Biospace Co Ltd shall not be liable for any errors incidental or consequential damages that occurred by not complying with the content of the User s Manual Biospace Co Ltd reserves the right to modify the appearance specifications and etc of the InBody370 to improve the quality of the product without prior notice for reasons of performance improvement 1996 Biospace Co Ltd All rights reserved BM USA 81 A 130927 InBody370 User s Manual Contents I InBody370 Installation A Product Components B Operating Environment C Installation Instructions
12. TION Do not spray any liquid substance directly onto the device Ne pulverisez aucune substances liquids directement sur l appareil D CAUTION No excessive force on shoulder joint Ne pas appliquer de force excessive sur les bars articul s C Classification Body Composition Analyzer of Direct Segmental Multi frequency Bioelectrical Impedance Analysis Method Type of protection against electric shock Class I Type of the applied parts BF Type Degree of protection against water infiltration IPX0 EMC Immunity Level A e EMC Emission Level A Equipment is not suitable for use in the presence of flammable mixtures D Specifications Bioelectrical Biodlectical 15 Impedance Measurements by Using 3 Different Frequencies Impedance Analysis BIA 5kHz 50kHz 250kHz at Each of 5 Segments Right Arm Left Arm Impedance Z Measurement Items Trunk Right Leg and Left Leg Electrode Method Tetrapolar 8 Point Tactile Electrodes Measurement Method Direct Segmental Multi frequency Bioelectrical Impedance Analysis Method DSM BIA Body Composition i SEN Calculation Method No Empirical Estimation Outputs Total Body Water Dry Lean Mass Lean Body Mass Body Fat Mass Weight Skeletal Muscle Mass Body Mass Index Percent Body Fat Segmental Lean Analysis Right Arm Left Arm Trunk Right Leg Left Leg Body Composition History Weight Skeletal Muscle Mass Percent Body Fat Body Fat Lean Body Mass
13. ace the InBody370 in a location making it difficult to disconnect the power cord Do not plug in or pull out the power cord with wet hands There is a risk of an electric shock Always use an outlet connected to the rated power AC 100 240 V Using other power rated outlets may result in fire or malfunction When using a power surge protector make sure the outlet or the extension cable has adequate power capacity Do not disassemble or modify the equipment including internal parts without written consent from the manufacturer This may cause electric shock or injury product malfunction inaccurate results and will void the manufacturer s warranty Do not directly contact the InBody370 with any other electronic devices when the InBody370 is on This may result in an electric shock A Caution If the InBody370 is not plugged into a grounded outlet it may cause damage through electric surges or product malfunction This may affect the test results Test results may be inaccurate if the InBody370 is under electrical interference Do not install the InBody370 near products that generate electrical interference such as fluorescent lights large AC motor equipment treadmill vibration plate refrigerator air conditioner compressor etc high frequency thermal therapy equipments or heating appliances Do not share the power source of the InBody370 with other electrical devices This may affect the test results Always use t
14. he specified adapter provided by BIOSPACE as it is a part of the InBody370 Using other adapters may result in malfunction of the InBody370 Operation of the InBody370 6 500 feet above sea level may affect the weight measurement 6 Flip the power switch to turn on the InBody370 LU Power switch ED CC a D Initial Setup 1 The InBody370 automatically starts booting when it is turned on While booting it performs a self weight calibration x While booting about 2 minutes and 30 seconds make sure there is nothing on top of the footplate Please do not stand on the footplate or place objects on the footplate 2 Press the SETUP button on the screen which appears when no one is on the footplate L DATABASE 3 SETUP 3 Input the password default password 0000 to have access the SETUP Enter password 1 2 3 4 5 6 Enter jejo oj 4 The SETUP will give you access to many different options such as basic settings touch calibration results sheet management printing options and more Touchscreen Allgnment 10 E Connecting Printer and Stadiometer 1 Printer In order to print InBody Results Sheets an InBody370 compatible printer is required A list of printers compatible with the InBody370 can be found at http www inbodyservice com 1 First turn off the InBody370 and then the printer You may experience connection iss
15. ith the InBody370 can be found at http www inbodyservice com Dimension 18 1 W x 26 7 L x 40 2 H inch 460 W x 677 L x 1020 H mm Equipment Weight 44lbs 20kg Test Time About 45 seconds Operation Environment 50 104 F 10 40 C 30 75 RH 70 106kPa Storage Environment 14 158 F 10 70 C 10 80 RH 50 106kPa No condensation 26 Testing Weight Range 22 551lbs 10 250kg Testing Age Range 3 99 years Testing Height Range 3 ft 1 4in 7ft 2 6in 95 220cm Specifications can be changed without a prior notice 2 www biospaceamerica com Copyright 1996 Biospace Co Ltd All rights reserved BM USA 81 A 130927 a
16. nagement procedure of BIOSPACE BIOSPACE complies with the ISO9001 and ISO13485 which are international quality management systems This equipment satisfies the IEC60601 1 EN60601 1 an international safety standard for electronic medical equipment This equipment also satisfies the IEC60601 1 2 EN60601 1 2 an international standard for electromagnetic conformity A Exterior and Functions The following are the names and functions of each part of the InBody Please inspect each component of the InBody370 for damage prior to installation 1 Upper Part LCD screen Shows each stage of the test instructions test results etc You can touch the screen to input the data required for the test configure settings or view test results Hand electrode Examinee holds the hand electrode so that the 4 fingers wrap the surface of the bottom hand electrode while the thumb is placed on the oval electrode Hand electrode joint and handle Supports the hand electrode and encloses the wiring for the electrode Body Connects the upper part of the equipment to the lower part lt Front gt oze Apogu lt Side gt 21 22 N Footplate 0 Front sole electrode The examinee makes contact with this electrode by stepping with the front part of their foot Rear sole electrode The examinee makes contact with this electrode by stepping with the heel of their foot Footplate This is connected
17. nd cover Joint screw gt Hexagonal wrench Stand cover A Caution A loose conjunction between the upper part and the footplate may affect test results Please make sure to tighten the joint screw to secure the upper part straight up on the footplate 4 Level the InBody370 by rotating the leveling screws under the footplate to the left and right so that the air bubble is centered Leveling the equipment is necessary for accurate measurement of weight There are a total of 6 leveling screws Level Indicator L eveled Not leveled Leveling screws under the footplate A Caution Avoid injuring your hands when rotating the leveling screws under the footplate 5 Connect the adapter to the power input port which is located on the rear panel of the InBody370 Connect the adapter to the power cord Then plug the power cord into a grounded 3 socket outlet The InBody370 can be used in connection with other test equipment such as a stadiometer or data management software called Lookin Body For more information please refer to A Exterior and Functions 3 Rear Panel in section V Others in this User s Manual 3 ou o o J i Rear panel Power input port L u CE 12V 3 4A Grounded outlet A Warning Do not pl
18. problem may occur if the power cord is not completely plugged into the adapter Insert the power cord completely into the adapter The problem may occur if you are using a power adapter that was not provide by BIOSPACE Always connect a power adapter DC 12V 3 4 A provided by BIOSPACE Power adapter Power cord 18 Ouestion Answer e My touchscreen is inaccurate or not responsive Calibrate the touchscreen under Touchscreen Alignment in SETUP Press firmly to optimize touchscreen response If you cannot enter the SETUP due to touchscreen problems please restart the InBody The InBody stores the last touchscreen alignment and will automatically recall the previous touchscreen settings The InBody can also recognize if its touchscreen alignment is off screen and will automatically take the user to the calibration screen after restarting I would like to connect other equipment to the InBody370 Please refer to E Connecting Printer and Stadiometer in section I InBody370 Installation in this User s Manual 19 20 B Regarding the InBody Test Some of the more common clinical questions are answered below If additional questions or more clarification is desired please contact BIOSPACE Question Answer e Must socks or stockings be removed for the InBody Test Bare skin contact is essential in the analysis using the BIA method Socks or stockings may ca
19. ptor BridgePower Corp Model BPM040S12FXX Input Voltage AC 100 240V 50 60Hz 1 2A Output Voltage DC 12V 3 4A MADE IN KOREA BIOSPACE Bhia a Compiles with UL60601 1 us CSA C22 2 No 601 1 E 113150 81 F 115 D 130814 mi Biospace Co LTD 15 Heugam gi Ipjang myeon Seobuk gu Cheonan si Chungch eongnam do 33 824KOREA TEL 82 41 581 3003 FAX 82 41 581 3103 Website www biospaceamerica com E mail USA biospaceamerica com X C o120 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operations Follow instructions for use Suivez les instructions d utilisation WARNING Electric shock hazard do not dismantle Dismantling will void the warranty AVERTISSEMENT Risque de choc lectrique ne pas d monter Le d montage annulera la garantie WARNUNG Stromschlaggefahr nicht auseinandernehmen Falls das Geh use ge ffnet wird erlischt die Garantie DANGER Do not use this equipment with electrical medical devices such as a pacemaker Ne pas utiliser cet quipement avec des appareils m dicaux lectriques comme un stimulateur cardiaque Verwenden Sie dieses Ger t nicht mit elektrischen Medinische Ger ten wie z B Herzschrittmachem CAUTION Do
20. ues in connecting the printer to the InBody370 if the InBody is turned on 2 Plug the USB cable provided with the printer into the USB HOST port on the rear panel of the InBody370 and plug the other end of the USB cable into the printer USB HOST port 3 Turn on the printer 4 Turn on the InBody370 and setup your printer under SETUP Printer Printer Type exit 2 Stadiometer If a stadiometer is connected to the InBody370 the height values measured by the stadiometer will be sent directly to the InBody370 Always connect a stadiometer from BIOSPACE 1 Set serial port COM1 as stadiometer in Accessories under SETUP 2 Plug the serial cable provided with the stadiometer to the 9 pin stadiometer serial port on the rear panel of the InBody370 9 pin stadiometer serial port 3 Turn on the stadiometer Stadiometer From BIOSPACE 11 12 F Maintenance AN Caution Do not bend the handles of the hand electrode Do not place any objects on the footplate Do not apply excessive force on the equipment Turn off the equipment if you are not using it for a day or longer Do not allow any liquid substances contact to the equipment directly Keep food and drinks away from the equipment Substances getting inside the equipment can cause critical damage to the electronic components Use a lint free cloth to gently wipe the external surface of the
21. use a varying degree of distortion in the results Socks or stockings must be removed to obtain accurate data Is it okay to wear accessories jewelry watch rings etc or metal objects while taking the InBody Test The ideal condition for the analysis is simply standing with no clothes and wearing no accessories However this may not always be possible Therefore we recommend that the examinee remove as many clothing items and accessories that may affect the weight as possible Who cannot take the InBody Test or will have difficulties taking the InBody Test Individuals with medical implant devices such as pacemakers or essential support devices such as patient monitoring systems must not use this equipment The currents will flow through the body during the test which may cause malfunctioning of the device or endanger lives Children amputees or the elderly may have trouble testing if they cannot hold the hand electrodes or stand still on the foot electrodes Can a person with metal implants in the body take The ideal test methodology is where the examinee does not wear anything metallic Individuals with metallic implants may have skewed test results the InBody Test due to the conductivity of the metal affecting the results As the weight of clothes and other wear affects the results of the body composition analysis it is strongly recommended to take off any heavy clothing or metallic wear