USER`S MANUAL - HellermannTyton
Contents
1. MAY 600A 600V CATI MKO A A HoD u SELECT z SFE OFF V uAQ nail L MAX COM oovcaru F A USER S MANUAL Twin Displays TBM126 Single Display TBM3030 e Versatile Clamp on Multimeter Series BRYMEN BRIGHT PEOPLE S CHOICE HellermannTyton 1 1 SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in a safe operating condition If the instrument is used in a manner not specified by the manufacturer the protection provided by the instrument may be impaired The meter meets the requirements for double insulation to IEC61010 2 032 EN61010 2 032 UL61010B 2 032 IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed Category III 600 Volts ac and dc PER IEC61010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATEGORY Il is energy consuming equipment to be supplied from the fixed installation Note Examples include household office and laboratory appliances OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation OVERVOLTAGE CATEGORY IV Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation Note Examples include electricity mete
2. Jaw marking lines for ACA position error indication 4 4 OPERATION CAUTION Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to determine proper meter functioning 110M F2 SELECT DC Voltage AC Voltage Hz Freguency functions Set slide switch to Voltage function position s Inputs are made through the test leads terminals For Twin Display Models slide switch on defaults at AC voltage Press SELECT button momentarily to select DC voltage Press the Hz button momentarily to activate Hz Frequency function in the following Slide switch functions Single Display Models DCV amp ACV via the test leads ACA via the clamp jaw Twin Display Models DCV ACV DCuA amp ACuA via the test leads not available to ACA Note DC 400 0mV range is designed with 1000MQ high input impedance for least current drain in measuring small signals and can cope better with most commercially available voltage output transducers adapters The non zero display reading is normal when the meter inputs are open circuit which will not affect actual measurement accuracy The meter will show close to zero readings when the inputs are shorted Open input is actually a floating condition which is not a zero volt input condition Note The Hz trigger level is determined by the selected function range from mae the Hz function is activated In ACV function Ac
3. the input jacks and turn OFF the meter before opening the case Do not operate with open case Trouble Shooting If the instrument fails to operate check batteries and test leads etc and replace as necessary Double check operating procedure as described in this user s manual If the instrument voltage resistance input terminal has subjected to high voltage transient caused by lightning or switching surge to the system by accident or abnormal conditions of operation the series fusible resistors will be blown off become high impedance like fuses to protect the user and the instrument Most measuring functions through this terminal will then be open circuit The series fusible resistors and the spark gaps should then be replaced by qualified technician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service 11 Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for periods of longer than 60 days remove the batteries and store them separately Battery replacement The meters use standard 3V IEC CR2032 coin batteries In Signle Display Model One battery is used In Twin Display Model Two batteries are used One is used for slide switch functions and the other one is used for the twin display ACA function separately Loosen the two screws from the case bottom and remove the bottom case Slide the battery
4. the test leads connections reverse biased across the diode The digital display shows OL if the diode is good Any other readings indicate the diode is resistive or shorted defective qF Capacitance function Inputs are made through the test leads terminals Slide switch on defaults at Q Press SELECT button momentarily 3 times to select AF Capacitance function Note applies to Model TBM3030 only Relative zero A mode can be used to zero out the parasitic capacitance of the leads and the internal protection circuitry of the meter when measuring low capacitance in the order of Pico Farad pF CAUTION Discharge capacitors before making any measurements Large value capacitors should be discharged through an appropriate resistance load ACA function Inputs are made through the clamp jaws for non invasive ACA current measurements For Single Display Models set the slide switch to select the ACA function For dual inputs Twin Display Models press the OFF push button momentarily to power on and off the separate ACA function display The HOLD push button can also be used as the ACA function power on hotkey This twin display ACA function can be used simultaneously with the voltage or any other slide switch functions when making measurements 110M F4 MAX 600A 600V CAT m MAX A0 CAUTION Application and removal of the Clamp on meter For non invasive ACA current measurements pre
5. ERNATIONAL ELECTRICAL SYMBOLS AC Alternating Current DC Direct Current Application around and removal from hazardous live conductors is permitted 2 CENELEC Directives The instruments conform to CENELEC Low voltage directive 73 23 EEC and Electromagnetic compatibility directive 89 336 EEC 3 PRODUCT DESCRIPTION This user s manual uses only representative model s for illustrations Please refer specification details for function availability to each model A Caution Refer to the explanation in this Manual A Caution Risk of electric shock Earth Ground m Double Insulation or Reinforced insulation Fuse NN 110M F1 MAX 600A 600V CAT m MAX HOLD BA MAX 600A Transformer Clamp Jaw for AC current magnetic field pick up Hand Finger Barrier to indicate the limits of safe access of the meter during measurement Push buttons for special functions amp features Also as power ON OFF buttons for ACA function in Twin Display Models Push buttons for special functions amp features on Slide switch Selector functions Input Jack for all functions EXCEPT non invasive ACA current function Common Ground reference Input Jack for all functions EXCEPT non invasive ACA current function Slide switch Selector to turn the power ON OFF and Select a function 3 3 4 digits 4000 counts LCD display s Jaw trigger for opening the transformer clamp jaw Jaw center Indicators at where best ACA accuracy is specified
6. HER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE BRYMEN WILL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES BRYMEN BRIGHT PEOPLE S CHOICE BRYMEN TECHNOLOGY CORPORATION TEL 886 2 2226 3396 FAX 886 2 2225 0025 http www brymen com ED PRINTED ON RECYCLABLE PAPER PLEASE RECYCLE COPYRIGHT MMVIII Btc ALL RIGHTS RESERVED P N 7M1C 0921 A007 PRINTED IN TAIWAN
7. battery IEC CR2032 One battery for Single Display Models Two batteries for Twin Display Models Power Consumption 2 8mA typical except that 3 3mA typical for ACA function APO Timing Idle for 30 minutes APO Consumption 5uA typical on all model functions except that 40uA typical on voltage function of Models 127M amp 128M Dimension L190mm X W63mm X H32mm Weight 139 gm approx Jaw opening amp Conductor diameter 26mm max Accessories Test leads pair battery ies installed user s manual amp soft carrying pouch Banana plug type K bead probe Bkp60 x 1 Twin Display Model only Optional Accessories Banana pins to type K socket plug adapter Bkb32 Twin Display Model only 13 Special Features 30ms Max Hold Data Hold Relative Zero mode Single Display Model only Simultaneous A V A Q A C Twin Display Model only Slim jaws Light Weight ELECTRICAL SPECIFICATION Accuracy is reading digits number of digits or otherwise specified at 23 C 5 C amp less than 75 R H DC Voltage Accuracy 0 3 4d 0 5 3d 1 0 4d NMRR gt 50dB 50 60Hz CMRR gt 120dB DC 50 60Hz Rs 1kQ Input Impedance 10MQ 30pF nominal 1000MQ2 for 400 0mV range AC Voltage Accuracy 1 5 5d 2 0 5d CMRR gt 60dB DC to 60Hz Rs 1kQ Input Impedance nominal 10MQ 30pF ACA Current Clamp on RANGE 50Hz 60Hz 40 00A 1 5 8d 400 0A 1 5 8d Induced error from adjac
8. easured maximum value as fast as 30ms with auto ranging capability Press the MAX button for 1 second or more toggles to max feature in the following function s Single Display Models DCV ACV amp ACA functions Twin Display Models Upper display ACA function 10 Relative zero A mode Single Display Models only Relative zero A mode allows the user to offset the meter consecutive measurements with the displaying reading as the reference value The display will now show readings relative to the stored reference value That is display reading stored value Press the A button momentarily toggles to relative zero mode Auto ranging Where there is more than one measuring range under a selected meter function the LCD annunciator a turns on The meter will automatically switch to the best resolution range when making measurements No manual ranging selection is required Auto Power Off APO When the meter is on the Auto Power Off APO feature will switch the meter into a sleep mode automatically to extend battery life after approximately 30 minutes of no Slide switch nor push button operations To wake up the meter from APO press the buttons momentarily or set the slide switch to the OFF position and then slide back on again Always set the slide switch to the OFF position manually when the meter is not in use 5 MAINTENANCE WARNING To avoid electrical shock disconnect the meter from any circuit remove the test leads from
9. ent current carrying conductor 0 05 A 2 Specified accuracy is from 1 to 100 of range and for measurements made at the jaw center When the conductor is not positioned at the jaw center position errors introduced are Add 2 to specified accuracy for measurements made BEYOND jaw marking lines toward jaw opening 3 Add 8d to specified accuracy reading lt 10 of range Max Hold where applicable Specified accuracy 50 digits for changes gt 25ms in duration 14 Ohms Capacitance RANGE Accuracy RANGE 1 Accuracy 3 400 02 0 8 8d 500 0nF 5 000uF 3 5 6d 4 000kQ 40 00kQ 0 6 4d 400 0kQ2 4 000MQ 1 0 4d Additional 50 00nF range accuracy is 40 00MQ 2 0 4d not specified Open Circuit Voltage 0 4VDC typical 2 Accuracies with film capacitor or better 3 Specified with battery voltage above Audible Continuity Tester 2 8V approximately half full battery Audible threshold between 5Q and Accuracy decreases gradually to 12 at 1200 low battery warning voltage of approximately 2 4V Diode Tester ene DC uA Twin Display Model only Open Circuit Voltage Test Current RANGE Accuracy Burden Typical Voltage Hz Frequency 20004A 1 2 3d 2 8mV uA Sensitivity Sine RMS 400 0mV 350mV 10Hz 2kHz 10Hz 5kHz 10Hz 10Hz 10kHz 2000uA 1 5 5d 2 8mV uA 10Hz 5kHz 00 0 A 500uA 10Hz 30kHz Type K Temperature Twin Display 2000A 5004A 10Hz 30kHz Mode
10. l only RANGE Accuracy 400 0A3 eoa 40Hz 400H2 PANGE T Accuracy 5 E ii 0 Display counts 5000 3010C 5370C 3 30C Best resolution 0 001Hz AF 5720F 59 GOF Accuracy 0 5 4d STAs T 30 eae Available to Twin Display Model only 2 Available to Single Display Model only ae ee range amp accuracy inclu AC uA Twin Display Model only LIMITED WARRANTY BRYMEN warrants to the original product purchaser that each product it manufactures will be free from defects in material and workmanship under normal use and service within a period of one year from the date of purchase BRYMEN s warranty does not apply to accessories fuses fusible resistors spark gaps batteries or any product which in BRYMEN s opinion has been misused altered neglected or damaged by accident or abnormal conditions of operation or handling To obtain warranty service contact your nearest BRYMEN authorized agent or send the product with proof of purchase and description of the difficulty postage and insurance prepaid to BRYMEN TECHNOLOGY CORPORATION BRYMEN assumes no risk for damage in transit BRYMEN will at its option repair or replace the defective product free of charge However if BRYMEN determines that the failure was caused by misused altered neglected or damaged by accident or abnormal conditions of operation or handling you will be billed for the repair THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OT
11. nute current changes in flame detector 9 applications Flame signal current check should indicate steady flame signal of at least 2uA for a rectification type or 1 5uA for an ultraviolet type 8uA for self checking systems If a flame signal current with inadequate strength or fluctuation beyond 10 check the following to avoid the risk of unwanted flame relay dropout 1 1 For gas or oil flames Minipeeper Low supply voltage Detector location Defective detector wiring Dirty viewing windows Faulty Minipeeper 1 2 For oil flames Photocell Detector location amp wiring Smoky flame or poorly adjusted air shutter Faulty Photocell Temperature over 165 F 74 C at photocell 1 3 For gas flames Flame Rod Ignition interference A flame signal current difference with the ignition both on and off greater than 0 5uA indicates the presence of ignition interference Insufficient ground must be at least 4 times the detector area Flame lifting off burner head ground or not continuously in contact with the flame rod Temperature in excess of 600 F 316 C at the flame electrode insulator causing short to ground HOLD The hold feature freezes the display for later view Press the HOLD button momentarily toggles to hold mode in the following function s Single Display Models All functions Twin Display Models Upper display ACA function MAX 0 The max feature compares and displays the m
12. out the side of the holder and replace with a new battery observe polarity Replace the bottom case Re fasten the screws GENERAL SPECIFICATION Display 3 3 4 digits 4000 counts LCD display s Update Rate 3 per second nominal Polarity Automatic Low Battery Below approx 2 4V Operating Temperature 0 C to 40 C Relative Humidity Maximum relative humidity 80 for temperature up to 31 C decreasing linearly to 50 relative humidity at 40 C Altitude Operating below 2000m Storage Temperature 20 C to 60 C lt 80 R H with battery removed Temperature Coefficient nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Sensing Average sensing Overload Protections ACA Clamp on jaws AC 600A rms continuous uA amp COM terminals 600VDC VAC rms Transient protection 6 5kV 1 2 50 us surge for all models Safety Meets IEC61010 2 032 EN61010 2 032 UL61010B 2 032 IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed Measurement Category III 600 Volts ac amp dc Pollution degree 2 E M C Meets EN61326 1997 1998 A1 EN61000 4 2 1995 2000 A2 and EN61000 4 3 2002 In an RF field of 3V m Capacitance function is not specified UA function Twin Display Model only Total Accuracy Specified Accuracy 65 digits Other function ranges Total Accuracy Specified Accuracy 45 digits Performance above 3V m is not specified Power Supply 3V coin
13. rs and primary over current protection equipment TERMS IN THIS MANUAL WARNING identifies conditions and actions that could result in serious injury or even death to the user CAUTION identifies conditions and actions that could cause damage or malfunction in the instrument 2 WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture The meter is intended only for indoor use To avoid electrical shock hazard observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC rms These voltage levels pose a potential shock hazard to the user Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to determine proper meter functioning Keep your hands fingers behind the hand finger barriers of the meter and the test leads that indicate the limits of safe access of the hand held part during measurement Inspect test leads connectors and probes for damaged insulation or exposed metal before using the instrument If any defects are found replace them immediately This Clamp on meter is designed to apply around or remove from uninsulated hazardous live conductors But still individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible CAUTION Disconnect the test leads from the test points before changing meter functions INT
14. ss the jaw trigger and clamp the jaws around only one single conductor of a circuit for load current measurement Make sure the jaws are completely closed or else it will introduce measurement errors Enclosing more than one conductor of a circuit will result in differential current like identifying leakage current measurement Locate the conductor s at the Jaws center as much as possible to get the best measuring accuracy For removal press the jaw trigger and remove the jaws from the conductor s Adjacent current carrying devices such as transformers motors and conductor wires will affect measurement accuracy Keep the jaws away from them as much as possible to minimize influence Temperature function Twin Display Model only Be sure to insert the banana plug type K temperature bead probe Bkp60 with correct polarities Slide switch on defaults at degree C Celsius Press SELECT button momentarily to select degree F Fahrenheit You can also use a plug adapter Bkb32 Optional purchase with banana pins to type K socket to adapt other type K standard mini plug temperature probes UA Current function Twin Display Model only Inputs are made through the test leads terminals Slide switch on defaults at DC Press SELECT button momentarily to select AC Application notes The DCuA function is designed especially for HVAC R flame sensor applications The 0 1 UA resolution is useful for identifying the mi
15. tivating the Hz function during significant measurements can get the most appropriate trigger level to avoid electrical noises in most cases Electrical noise may cause unstable Hz reading Activating the Hz function at AC 4 000V range before making significant measurements can get lower trigger level higher sensitivity Hz reading may show zero when the sensitivity is insufficient MAX 600 600V CAT II gt CAUTION Using Resistance Continuity Diode or Capacitance function in a live circuit will produce false results and may damage the instrument In many cases the suspected component must be disconnected from the circuit to obtain an accurate measurement reading 6 Q Resistance and Continuity functions Inputs are made through the test leads terminals Slide switch on defaults at Q Press SELECT button momentarily to select Continuity function which is convenient for checking wiring connections and operation of switches A continuous beep tone indicates a complete wire Diode test function Inputs are made through the test leads terminals Slide switch on defaults at Q Press SELECT button momentarily 2 times to select gt Diode test function Normal forward voltage drop forward biased for a good silicon diode is between 0 400V to 0 900V A reading higher than that indicates a leaky diode defective A zero reading indicates a shorted diode defective An OL indicates an open diode defective Reverse