Home
PAB Set Up Manual englisch neu
Contents
1. A A Pressuredie Device Wastes ny a l aac e SEEE LL Coee e o Said Device owe v pressure air bic 3 You have to insert the PAB device Click on the Insert Icon or choose Edit if you want to make changes to an already existing device FO Insert 4 Enter any name you choose for your PAB device in the Device box e g PAB Device 5 Choose the USB port to which your PAB device is connected to in the drop down menu in the Serial Device box after clicking on the drop down arrow 6 Click on the save icon save the data After that the entered PAB device will appear in the bottom window a f For calibration click on the PAB device which is available in the window 8 Insert the Needle of the PAB device in the needle valve of one of the TOGU products which are part of the PAB set Please make sure to moisten the needle prior to inserting it and be careful not to harm the valve or the surface of the product 9 Click in the upper bar on the Calibrate icon Copyright PAB and TOGU Gebr Obermaier oHG 8 10 A window showing the inside pressure will appear Click the OK button You have set the calibration value Example Handgrip Bodyroll is calibrated at 0 00 release all air Touch ball is calibrated at 150 155 mbar Dynair Ballkissen Senso is calibrated at 0 3 0 7 mbar Note In order to ensure comparable test results the calibration value has
2. Patient Code the patient you want to test Enter in the box Patient Mass the weight of the patient This needs to be done to determine the relative strength of the patient Enter the desired time period in seconds in the Duration box The test duration is not defined if O is entered and therefore the test will continue until stopped manually by clicking the Stop icon Choose in the box Devices which device you want to use for the test Save your own notes in the box Notes Click on the Start icon 10 The chart window will open and the test starts The test ends either after the previously Note selected duration time has passed or if stopped by clicking on the stop icon The User Manual describes in detail how tests are performed and results evaluated This manual was part of your download and can be found in your PAB folder If you have further questions or problems running your PAB Program please contact support pressureairbiofeedback com Copyright PAB and TOGU Gebr Obermaier oHG 10
3. click the Pressure Air icon 3 The login window will show For the first time using the program type admin for User and admin for Password as seen below Simple amp Scientific p q D Program PressureAir pressure air biofeedback Version 3 2 1 357 User Luke Bodmann OS Windows 7 Home Premium OS Version Service Pack 1 Processor Intel R Core TM 15 CPU M 430 2 27GHz TotalMemory 2999 Mb Free Memory 1047 Mb 4 You will then see the main window All navigation in the program will be done via this window Piesserodis Pressure Al UNREGISTERED VERSIO I oe tO fetore A 9 Sea 2 Sop Lers Piet Devices th Rands gt t Tes Simple amp Scientific pressure air biofeedback Copyright PAB and TOGU Gebr Obermaier oHG 4 IV Program registration Going through the following steps you can register your PAB Program and receive the serial number which is needed for the registration 1 Click the Setup icon in the upper bar to start the registration process 2 The following window will show E setup t Company Naster UNREGISTERED VERSION Enter any name of your choice for example the company name Send an email with your Name and the Hardware ID number to support pressureairbiofeedback com the hardware ID number which is located just below the field for the entry of the serial number The serial number will be send to yo
4. I Program download and installation Please take your time to install the PAB Program without disruption Create a folder for your PAB program on your computer PAB Program folder In order to download the PAB program go to www pressureairbiofeedback com Click on Program download Save the file in the PAB Program folder which you have created on your computer before Start PAB_Self_Extract exe Select the Browse button after the WinRar Window opens up Select your PAB folder Click on Extract Go to Windows Explorer open your PAB folder and click on PAB_ Set up exe 10 Follow the instructions in the installation window which Opens up 11 Chose Option Create desktop Icon 12 After you went through all the steps in the installation window the Login window opens up Please insert in the field User and Password each time the word admin COONDORWN D pi eae T E E Fa L i 3 r E i ta A gt w rea r irm 2 k aeinn TtIFI FP Me f e lIc amp JLI i BL L a a amp ii E a Wk F Se l E oO Y Program PressureAir Version 3 2 1 357 User Luke Bodmann 0S Windows 7 Home Premium OS Version Service Pack 1 Processor Intel R Core TM 15 CPU H 430 2 27GHz Total Memory 2999 Hb Free Memory 1047 Hb 13 Wait until main window opens Sfa5 9 29 Q Patoma Simple amp Scientific AEAT pab pressure air biofeedback 14 Close the PAB program Copyright PAB and TOGU Gebr Obermaie
5. Patients You can add patients to PAB with their own profile for easy testing and viewing of results after multiple tests 1 Click on the Patient icon M Patents 2 The following window will appear g window will app _ Body Dynamics Patient Master UNREGISTERED VERSION Maintenance a Eo FY Fo Insert Edit Delete Patient Code DOEOOO 1 Surname First Hames ID Humber Doe John Address Telephone Numbers Area Code First Names al 3 You can insert and edit a patient by clicking on the insert and edit icon respectively To insert a new patient click the Insert icon FO Insert 4 You can now fill in the patient s details such as name surname ID number telephone number address and area code Once the details have been filled in click the Save icon to save the patient onto PAB i O Save 5 PAB will automatically create a Patient Code for the patient you just entered as seen by the arrow labelled 1 in step 2 You can now use that code to locate and view the patient for testing and results Click the Exit icon to exit the Patient Master window Q Exit Copyright PAB and TOGU Gebr Obermaier oHG 7 Devices The PAB device has to be calibrated before running a test Proceed as follows 1 Click on the Devices Icon 2 The following window will apprear Actora o Senee O 0 Q Jep Lewe P tiers ms Rese foot Dt p l Simple amp Scientific
6. owse my computer for driver software lento i h l Update Driver Software CDC Virtual Com How do you want to search for driver software Search automatically for updated driver software Windows will search your computer and the Internet for the latest driver software for your device unless you ve disabled this feature in your device installation settings gt Browse my computer for driver software Locate and install driver software manually T Navigate to the PressurAir directory and click NEXT and allow your pc to run install program _ Update Driver Software CDC Virtual Com Browse for driver software on your computer Search for driver software in this location Ml Include subfolders Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device 8 When complete and driver is installed close window and exit Device Manager s we i Update Driver Software Pressure Air Dewice COML16 Windows has successfully updated your driver software Windows has finished installing the drier software for this device Pressure Air Dewice Copyright PAB and TOGU Gebr Obermaier oHG 3 lil Programm Setup 1 Ensure that your PAB unit device is connected to the computer prior to starting the PAB programme 2 Tostart your PAB program double
7. r oHG 1 Il Hardware Driver installation Before you can use your PAB program you need to install the hardware driver for your PAB device Please note that the following screenshots may vary from your actual screen view depending on the version of your operating system 1 Connect your PAB device little box with the USB port on your computer 2 The following message will pop up screen bar at the bottom right side IR Device driver software was not successfully installed gt Click here for details 3 Navigate from start to control panel system device manager 4 Select the options which apply to you in the hardware assistant Device Manage File Action View Help m H fal amp a m Webtex Lap2 gt ep Batteries 2 Biometric Devices gt B Bluetooth p gi Computer b Sy Disk drives lik Display adapters b gt mi DVD CD ROM drives aie Human Interface Devices 4g IDE ATA ATAPI controllers b 23 Imaging devices pF Jungo gt 2 Keyboards og a gt Mice and other pointing devices lls Monitors gt RY Network adapters a j Other devices ifa CDC Virtual Com a 13 Ports COM amp LPT gt Processors 5 Click on CDC Virtual Com and then click on update driver software Update Drier Software Disable Uninstall Scan for hardware changes Froperties Copyright PAB and TOGU Gebr Obermaier oHG 2 6 Click on selection box br
8. to be the same everytime a test is repeated Deviations of up to 5 Milibars are acceptable 11 You can choose and define an individual calibration value For this you need to connect the ballpump with the tube as shown on the picture below f 12 STurn the blue control knob parallel to the tube until it snaps see picture Open i Open Closed 13 Pump carefully until the chosen pressure value appears in the calibration window in the screen 14 In order to reduce air pressure unscrew the needle off the ballpump Insert only the needle as shown in step 11 Let out air until the desired value appears in the calibration window on the screen 15 Ist After you are done remove the needle from the valve and turn the control knob to a perpendicular position to the tube see picture Closed 16 Click on the Exit icon to leave the calibration window Copyright PAB and TOGU Gebr Obermaier oHG 9 Perform Test The PAB is now ready to perform a test 1 2 iate O 0 O Click on the Perform Test Icon The following window will appear Perfors Tes e Simple amp Scientific an Patar Coce v Joha Dew 1D Merbe 12345070 20 Test Tree pressur 2 7 8 9 Choose the patient which will be tested This patient has been created before in the PAB Program as described above Chapter V Settings Patients Click on the Insert icon L E E Insert Choose in the box
9. u by email This can take some minutes Upon receiving your Serial Number via email you can now type it in under the Serial Number Click the Save icon to register the program F save Click the Exit icon to exit the Setup window G Exit Copyright PAB and TOGU Gebr Obermaier oHG 5 V Settings User You can define one or more users for the program Follow these steps to create a profile for each user 1 Click the User icon na Users 2 The following window will appear Maintenance bE REER 0000o bia Edit Delete Save Cancel First Previous Next Last About Record Record Record Record First Names R b admin 00min ge H a 1 Luke 3 Click the Insert icon to enter a new user a FO Insert 4 Enter your Last and First Name in the relevant boxes 5 User Level is set at level 2 as seen in the image above You can also click on the drop down arrow as seen in the image below and change the User Levels accordingly Hence Level 0 only allows the user to perform tests Level 1 user has access to the entire programme except to view results and Level 2 user has full access 6 By Login as seen in the image above you can change your login and password to your own personal one T Click the Save icon to save user a O Save 8 Click the Exit icon to exit the Users window Q Exit Copyright PAB and TOGU Gebr Obermaier oHG 6
Download Pdf Manuals