Home

8-Port 10/100Mbps PoE Fast Ethernet Switch FSD-808P

image

Contents

1. Why connects PoE device to FSD 808P and it cannot power on m Solution 1 Please check the cable type of the connection from FSD 808P port 1 to port 8 to the other end The cable should be an 8 wire UTP Category 5 or above EIA568 cable within 100 meters A cable with only 4 wire short loop or over 100 meters all will affect the power supply 2 Please check and assure the device that fully complied with IEEE 802 3af stan dard What is the power output of each IEEE 802 af PoE port E Solution Each PoE port supports 48V DC 350mA max 15 4 Watts power output Detect and inject by the standard of IEEE 802 3af Appendix A Networking Connection A 1 Data out PoE Switch RJ 45 Port Pin Assignments PIN NO RJ 45 SIGNAL ASSIGNMENT Output Transmit Data Output Transmit Data Receive Data Positive Power Positive Power Receive Data Negative Power co ov Ui S oo n Negative Power A 2 10 100Mbps 10 100Base TX When connecting Switch to another Fast Ethernet switch a straight or crossover cable might necessary Each port of the Switch supports auto MDI MDI X detection That means you can directly connect the Switch to any Ethernet devices without making a crossover cable The following table and diagram show the standard RJ 45 receptacle connector and their pin assignments RJ 45 Connector pin assignme
2. To install the Switch on desktop simply follow the next steps Step 1 Attach the rubber feet to the recessed areas on the bottom of the Switch as shown in Figure 3 1 Figure 3 1 Attaching the Rubber Feet to the POE Fast Ethernet Switch Step 2 Place the Switch on desktop near an AC power source Step 3 Keep enough ventilation space between the Switch and the surrounding objects When choosing a location please keep in mind the environmental restrictions discussed in Chapter 1 Section 4 in Specification Step 4 Connect your Switch to 802 3af complied Power Devices PD and other network devices A Connect one end of a standard network cable to the 10 100 RJ 45 ports at front panel of the Switch B Connect the other end of the cable to the network devices such as printer servers workstations or routers etc Connection to the Switch requires UTP Category 5 5e 6 network cabling with RJ 45 tips For more information please see the Cabling Specification in Appendix A Step 5 Supply power to the Switch A Connect one end of the power cable to the Switch B Connect the power plug of the power cable to a standard wall outlet When the Switch receives power the Power LED should remain solid Green 3 2 Rack Mounting To install the Switch in a 12 inch standard rack follow the instructions described below Step 1 Place your POE Fast Ethernet Switch on a hard flat surface with the f
3. Ww o 2 4GHz 802 11n 802 3af PoE Wu x VoIP ATA Bio Z 802 3af PoE Phone 802 3af PoE 802 3af PoE 802 3af PoE Wireless AP VoIP Phone IP Camera IP Camera Up to 8 PoE Powerd Devices Figure 3 5 Department workgroup PoE Switch Connection 3 4 Power over Ethernet Powered Device gt Voice over IP phones Enterprise can install POE VoIP Phone ATA and other Ethernet non Ethernet end devices to the central where UPS is installed 3 5 Watts for un interrupt power system and power control system Wireless LAN Access Points Museum Sightseeing Airport Hotel Campus Factory Warehouse can install the Access Point any where with no 6 12 Watts hesitation E IP Surveillance T 4 Enterprise Museum Campus Hospital Bank can install IP Camera without limits of install location no need electrician to 10 12 Watts install AC sockets PoE Splitter j PoE Splitter split the PoE 48V DC over the Ethernet cable into 5 12V DC power output It frees the device deployment from restrictions due to power outlet locations which eliminate the 3 12 Watts costs for additional AC wiring and reduces the installation time A 14 4 Power over Ethernet Overview What is PoE Based on the global standard IEEE 802 3af PoE is a technology for wired Ethernet the most widely installed local area network technology adopted today PoE allows the electrical power necessary for the operation of ea
4. PoE Inject Port 8 Port RJ 45 for 10 100Base TX 8 Port with 802 3af PoE injector function LED Display System Power Green Per port PoE Green LNK ACT Green Switch Architecture Store and Forward switch architecture MAC Address 2K MAC address table with Auto learning function Switch Fabric 1 6Gbps Switch Throughput 1 19Mpps 64Bytes Power Requirement AC 100 240V 50 60Hz 1 54 max Power Consumption Max 135 Watts 460 BTU Dimension W x D x H Weight 280 x 180 x 43 mm 1 65kg Power over Ethernet PoE Standard IEEE 802 3af Power over Ethernet PSE PoE Power Supply Type Mid Span PoE Power Output Per Port 48V DC 350mA Max 15 4 Watts Power Pin Assignment 4 5 7 8 PoE Power Budget 125 Watts Standard Conformance EMI Safety FCC Class A CE Standard Compliance IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3x Flow Control IEEE 802 3af Power over Ethernet Environment Operating environment 0 50 Degree C Storage environment 40 70 Degree C Operating Humidity 5 95 relative humidity non condensing Storage Humidity 5 95 relative humidity non condensing 2 Hardware Description This product provides two different running speeds 10Mbps and 100Mbps in the same switch and automatically distinguishes the speed of incoming connection
5. This section describes the hardware features of FSD 808P For easier management and control of the Switch familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting any network device to the FSD 808P please read this chapter carefully 2 1 Front Panel The Front Panel of the FSD 808P PoE Ethernet Switch consists of 8x Auto Sensing 10 100Mbps Ethernet RJ 45 Ports The LED Indicators are also located on the front panel of the FSD 808P 8 Port 10 100Mbps PoE Ethernet Switch FSD 808P Figure 2 1 FSD 808P Switch Front Panel 2 1 1 LED Indicators System LED Color Function PWR Green Light Indicate the Switch has power Per 10 100Mbps Port LED Color Function PoE Green Light Indicate the port is providing 48V DC in line power Light Indicate the link through that port is successfully established Blink Indicate that the Switch is actively sending or receiving data over that port LNK ACT Green 2 2 Rear Panel The rear panel of the FSD 808P indicates an AC inlet power socket which accepts input power from 100 to 240V AC 50 60Hz 100 240V AC 50 60Hz Figure 2 2 FSD 808P Switch Rear Panel 1 The device is a power required device it means it will not work till it is powered If your networks should active all the ga time please consider using UPS Uninter
6. pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Energy Saving Note of the Device This power required device does not support Standby mode operation For energy saving please remove the power cable to disconnect the device from the power circuit Without removing power cable the device will still consuming power from the power source In the view of Saving the Energy and reduce the unnecessary power consuming it is strongly suggested to remove the power connection for the device if this device is not intended to be active WEEE Warning To avoid the potential effects on the environment and human health as a K result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should
7. s Name Planet Technology Corp Manufacturer s Address 10F No 96 Minquan Rd Xindian Dist New Taipei City 231 Taiwan R O C is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on 2004 108 EC For the evaluation regarding the EMC the following standards were applied EN 55022 Class A 2006 A1 2007 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2008 EN 55024 1998 A1 2001 A2 2003 TEC 61000 4 2 2008 TEC 61000 4 3 2008 TEC 61000 4 4 2004 TEC 61000 4 5 2005 IEC 61000 4 6 2008 IEC 61000 4 8 2009 TEC 61000 4 11 2004 Responsible for marking this declaration if the Manufacturer O Authorized representative established within the EU Authorized representative established within the EU if applicable Company Name Planet Technology Corp Company Address 10F No 96 Minquan Rd Xindian Dist New Taipei City 231 Taiwan R O C Person responsible for making this declaration Name Surname Kent Kang Position Title Product Manager fox ge Taiwan 25 Aug 2011 J Place Date Legal Signature PLANET TECHNOLOGY CORPORATION e mail sales planet com tw http www planet com tw 10F No 96 Minquan Rd Xindian Dist New Taipei City Taiwan R O C Tel 886 2 2219 9518 Fax 886 2 2219 9528
8. 8 Port 10 100Mbps PoE Fast Ethernet Switch FSD 808P User s Manual Trademarks Copyright PLANET Technology Corp 2011 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device
9. ch end device to be carried by data cables rather than by separate power cords New network applications such as IP Cameras VoIP Phones and Wireless Networking can help enterprises improve productivity It minimizes wires that must be used to install the network for offering lower cost and less power failures IEEE 802 3af also called Data Terminal equipment DTE power via Media dependent interface MDI is an international standard to define the transmission for power over Ethernet The 802 3af is delivering 48V power over RJ 45 wiring Besides 802 3af also define two types of source equipment Mid Span and End Span m Mid Span Mid Span device is placed between legacy switch and the powered device Mid Span is tap the unused wire pairs 4 5 and 7 8 to carry power the other four is for data transmit W End Span End Span device is direct connecting with power device End Span could also tap the wire 1 2 and 3 6 PoE System Architecture The specification of PoE typically requires two devices the Powered Source Equipment PSE and the Powered Device PD The PSE is either an End Span or a Mid Span while the PD is a PoE enabled terminal such as IP Phones Wireless LAN etc Power can be delivered over data pairs or spare pairs of standard CAT 5 cabling How is Power Transferred Through the Cable A standard CAT5 Ethernet cable has four twisted pairs but only two of these are used for 10BASE T and 100BASE T The specificati
10. icas nente niche min a S tais ue Ki ssa RB RE ENS 15 5s Itoubleshootihgi scenes e deest sexe ne eee n xc a hawondiex sess us ui vds Rd usa Teri E ET 18 Appendix A Networking CONNECTION isesi spna o na mina desistit aa Fd miu a nn 19 A 1 Data out PoE Switch RJ 45 Port Pin Assignments Port 1 to Port 8 19 A 2 10 100Mbps 10 100Base TX ser tron teret aaa 19 1 Introduction 1 1 Checklist Check the contents of your package for following parts e FSD 808P x 1 User s Manual x 1 Power Cord x 1 Two Rack mounting Brackets with Attachment Screws x 8 If any of these pieces are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to return it to us for repair 1 2 Product Description To fulfill the demand of sufficient PoE power for network applications with Fast Ethernet transmission performance the new member in the 802 3af PoE Fast Ethernet Switch family FSD 808P the 8 Port 10 100Mbps Power over Ethernet Switch which features high performance Fast Ethernet IEEE 802 3af PoE Up to 15 4 Watts and totally 125 Watts PoE budget The eight 802 3af PoE ports provide PoE power injector function which is able to drive 8 IEEE 802 3af compliant powered devices The FSD 808P also provides a simple cost effective and non blocking wire speed performance with 12 inch me
11. id another electrician s payment References IEEE Std 802 3af 2003 Amendment to IEEE Std 802 3 2002 including IEEE Std 802 3ae 2002 2003 Page s 0 1 121 White Paper on Power over Ethernet IEEE 802 3af http www poweroverethernet com articles php article id 52 Microsemi PowerDsine http www microsemi com PowerDsine Linear Tech http www linear com 17 1 5 Troubleshooting This chapter contains information to help you solve issues If the Switch is not functioning properly make sure the Ethernet Switch was set up according to instructions in this manual The Link LED is not light m Solution Check the cable connection and remove duplex mode of the Switch Performance is bad m Solution Check the full duplex status of the Switch If the Ethernet Switch is set to full duplex and the partner is set to half duplex then the performance will be poor 100Base TX port link LED is light but the traffic is irregular m Solution Check that the attached device is not set to dedicate full duplex Some devices use a physical or software switch to change duplex modes Auto negotiation may not recognize this type of full duplex setting Why the Switch doesn t connect to the network m Solution Check the LNK ACT LED on the switch Try another port on the Switch Make sure the cable is installed properly Make sure the cable is the right type Turn off the power After a while turn on power again
12. nt MDI MDI X Contact i Media Dependant Interface Media Dependant Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive Tx transmit 4 5 Not used 6 Rx receive Tx transmit 7 8 Not used There are 8 wires on a standard UTP STP cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Straight Cable TET 1234567 Cross Over Cable orno SIDE 2 12345678 Pad 12345678 SIDE 1 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown SIDE 1 SIDE 2 1 White Orange 1 White Green 2 Orange 2 Green 3 White Green 3 White Orange 4 Blue 4 Blue 5 White Blue 5 White Blue 6 Green 6 Orange 7 White Brown 7 White Brown 8 Brown 8 Brown Figure A 1 Straight Through and Crossover Cable Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network 19 1 9 PLANET Networking amp Communication EC Declaration of Conformit For the following equipment Type of Product 8 Port 10 100Mbps PoE Fast Ethernet Switch Model Number FSD 808P Produced by Manufacturer
13. on allows two options for using these cables for power shown in Figure 2 and Figure 3 The spare pairs are used Figure 2 shows the pair on pins 4 and 5 connected together and forming the positive supply and the pair on pins 7 and 8 connected and forming the negative supply In fact a late change to the spec allows either polarity to be used POWER SOURCING POWERED DEVICE EGUIPMENT PSE PD X0 x a ep zx SIGNAL PAIR Figure 1 Power Supplied over the Spare Pins The data pairs are used Since Ethernet pairs are transformer coupled at each end it is possible to apply DC power to the center tap of the isolation transformer without upsetting the data transfer In this mode of operation the pair on pins 3 and 6 and the pair on pins 1 and 2 can be of either polarity POWER SOURCING POWERED DEVICE EQUIPMENT PSE PD SPARE PAIR Figure 2 Power Supplied over the Data Pins When to install PoE Consider the following scenarios You re planning to install the latest VoIP Phone system to minimize cabling building costs when your company moves into new offices next month The company staff has been clamoring for a wireless access point in the picnic area behind the building so they can work on their laptops through lunch but the cost of electrical power to the outside is not affordable e Management asks for IP Surveillance Cameras and business access systems throughout the facility but they would rather avo
14. r switch or PC to the other port of FSD 808P by following the same process as described in Step 3 Power Line AC 100Base TX UTP 9 100BaseTX UTP with PoE Q 24GHz802 11n a A Amr A 10 100Base TX Data 802 3af PoE 802 3af PoE 802 3af PoE 802 3af PoE IP Camera VoIP Phone VoIP Phone Wireless AP Figure 3 4 End node or Switch Connection Cable distance for Switch The cable distance between the FSD 808P and PC should not exceed 100 meter for UTP STP cable Make sure the wiring is correct It can be used Category 3 4 5 cable in 10 Mbps operation To reliably operate your network at 100Mbps you must use an Unshielded Twisted Pair UTP Category 5 5e cable or better Data Grade cabling While a Category 3 or 4 cables may initially seem to work it will soon cause data loss 3 3 2 Department Workgroup PoE Switch Providing 8 Port PoE in line power interfaces the FSD 808P can easily build a power centrally controlled IP phone system IP Camera system and Wireless AP group for the enterprise For instance up to 8 cameras can be installed around the corner in the company for surveillance demands or up to 8 Wireless AP to build a wireless roaming environment in the office Without the power socket limitation the Switch makes the installation of cameras or Wireless AP more easily and efficiently 1008ase T UTP with PoE Uplink PowerLine AC i
15. ront panel positioned towards your front side Step 2 Attach a rack mount bracket to each side of the Switch with supplied screws attached to the package Figure 3 2 shows how to attach brackets to one side of the Switch Figure 3 2 Attaching the Brackets to the Switch You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect screws would invali date the warranty Step 3 Secure the brackets tightly Step 4 Follow the same steps to attach the second bracket to the opposite side Step 5 After the brackets are attached to the Switch use suitable screws to securely attach the brackets to the rack as shown in Figure 3 3 00000 ES 0000000 v Ld Figure 3 3 Mounting the Switch in a Rack Step 6 Proceeds with the steps 4 and steps 5 of session 3 1 Desktop Installation to connect the network cabling and supply power to your Switch 3 3 Product Application 3 3 1 Connecting end node or Switch 1 Place the FSD 808P on a smooth surface or fasten the mounting brackets purchased separately with the provided screws in a standard 12 rack 2 Connect the power cord to the power inlet socket of FSD 808P and the other end into the local power source outlet When the Switch receives power the Power LED should remain solid Green 3 Connect other switch or PC to one port of the FSD 808P using Category 3 4 5 5e UTP STP cabling 4 Connect anothe
16. rupted Power Supply for your device It will prevent you from network data loss or Power network downtime Notice 2 In some area installing a surge suppression device may also help to protect your FSD 808P from being damaged by unregu lated surge or current to the FSD 808P or the power adapter 3 Hardware Installation Start up Please refer to the followings for your cabling 10 100Base TX All 10 100Base TX ports come with Auto Negotiation capability They automatically support 100Base TX and 10Base T networks Users only need to plug a working network device into one of the 10 100Base TX ports and then turn on the FSD 808P The port will automatically runs in 10Mbps 20Mbps 100Mbps or 200Mbps after the negotiation with the connected device Cabling Each 10 100Base TX ports use RJ 45 sockets similar to phone jacks for connection of unshielded twisted pair cable UTP The IEEE 802 3 802 3u Fast Ethernet standard requires Category 5 5e UTP for 100Mbps 100Base TX 10Base T networks can use Cat 3 4 5 see table below Maximum distance is 100meters 328 feet Port Type Cable Type Connector 10Base T Cat 3 4 5 2 pair RJ 45 100Base TX Cat 5 5e UTP 2 pair RJ 45 Any Ethernet devices like hubs PCs can connect to the FSD 808P by using straight through wires The eight 10 100Mbps ports are auto MDI MDI X can be used on straight through or crossover cable 3 1 Desktop Installation
17. tal shape for desktop deployment in compact housing SOHO office or department network application All RJ 45 copper interfaces in the FSD 808P support 10 100Mbps Auto Negotiation for optimal speed detection through RJ 45 Category 5 or 5e cables It also supports standard Auto MDI MDI X that can detect the type of connection to any Ethernet device without requiring special straight or crossover cables 5E 1 3 Features RJ 45 Interface 8 Port 10 100Mbps Fast Ethernet ports 8 Port supports 48V DC power to PoE Powered Device Power over Ethernet Comply with IEEE 802 3af Power over Ethernet Mid Span PSE Up to 8 IEEE 802 3af devices powered Supports PoE Power up to 15 4 Watts for each PoE port Auto detect powered device PD Circuit protection prevents power interference between ports Remote power feeding up to 100m Switching Hardware based 10 100Mbps Auto Negotiation and Auto MDI MDI X Flow control for Full Duplex operation and back pressure for Half Duplex operation Integrates address look up engine supporting 2K absolute MAC addresses Automatic address learning and address aging Hardware 12 inch desktop size 1U height LED indicators for PoE ready and PoE activity 1 silent FAN to provide stable and efficient power performance 1 4 Specification Model FSD 808P 8 Port 10 100Mbps PoE Fast Ethernet Switch Hardware Specification Network Connector
18. understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Revision PLANET 8 Port 10 100Mbps PoE Fast Ethernet Switch User s Manual For Model FSD 808P Revision 1 0 July 2011 Part No 2351 A31190 000 Table Of Contents 1 IritEOG UCET aiucoocis oce os caecus se Das secessu hssa segs Tat uzu caa QA Une Exe zx Sia DiEs Scr eR PEh UE TE 5 MESI c4 EE 5 1 2 Prod ct Description ausa nipote tur RhphRR Re Rn Re deia daia bani 5 1 3 lm 6 1 4 SpecifiCatlOft cedet etre naaa obe parks hes a lcu xam A AEA 7 2 Hardware Descriptio Ms scindarea ar Ease ded daa ar PR CR Pa EN Ra ER 8 2 1 Pront Panels eonen n E NUN Sen dS 8 2 1 1 ED JndiCatOrs xcususso discessus duse Datos ope Inmadantasevanlomiacedstcuntadeataaies 8 PPPENIS IgE 9 3 Hardware InsStallati Oma ia irte ie oese kx duusd dote ne avandsatw laurels AA AEAEE 10 3 1 Desktop InstallatiOniss c duco vincti oxi exu tem squs i dduE Ker tous cane VI IN CNN ERUNI ME 10 3 2 Rack MOUNTING icerir aaaeeeaa E etna as Suena EDEN NEIE E DAR Rx 11 323 Product Applicators eu tea teen ts eren oed eder sieze ses PE ER SE IER M vende 13 3 3 1 Connecting end node or Switch sirsenis phann eee eee een eee ee 13 3 3 2 Department Workgroup POE Switch eeee eee ee arene 14 3 4 Power over Ethernet Powered DeviCe eene nennen nna 14 4 Power over Ethernet OVerVIGW ifsc ch

Download Pdf Manuals

image

Related Search

Related Contents

User`s Manual  Linux Solaris Windows  Manual de Instrucciones  DTU-1031 - German  SP-250™ → - Allied Time  Bell'O PR-32 flat panel floorstand  elation elar extqw bar hp user manual 1.0  Hps 446 patrol line  Jean-Pierre Lachaud  RECEPTOR 2-CANAIS RÁDIO ZMROP02  

Copyright © All rights reserved.
Failed to retrieve file