1. BARSKAN User s Manual for Biometric Safe Read all instructions before using this safe WARNING New Safe is in Factory Default mode ANY fingerprint can open the safe Only successful registered fingerprint can terminate Factory Default mode Register at least two different fingerprints and test a few times before closing the safe door Test with a non registered fingerprint If the safe opens the safe remains in Factory Default mode Avoid leaving safe door open and unattended it will allow unauthorized individuals to add their fingerprints and or reprogram the safe gaining full access to the safe and the contents Test the Emergency Keys and store them in a secure place NOT inside of the safe To maximize the security and performance of the safe test registered fingerprints every 6 months i O BARSKA O A Initialization Button F Wake Up Button B Battery Compartment G Logo Plate and Emergency C Bolts Key Access D Fingerprint Scanner H External Battery Access E Indicator Lights optional Actual model may vary 1 OPEN SAFE WITH EMERGENCY KEY 1 To Expose the Emergency Key Access remove silver Logo Plate G screws with provided allen wrench 2 Insert Emergency Key into key access and turn clockwise to open NOTE Store Emergency Keys in a secure place NOT inside of the safe 2 INSTALL BATTERIES 1 Remove Battery Compartment B cover 2
2. Insert 4 AA batteries and restore battery cover 3 Bolts C automatically extend when batteries are inserted To retract bolts Press and release Wake Up Button F Place any finger on the Fingerprint Scanner D Bolts will retract 3 FINGERPRINT REGISTRATION IMPORTANT The safe is in Factory Default mode ANY fingerprint can open the safe Only successful registered fingerprint can terminate Factory Default mode During registration the door must remain open and the Bolts C must be in the retracted position Otherwise the fingerprint will not be saved To retract bolts Press and release Wake Up Button F Place any finger on Fingerprint Scanner D Bolts will retract 1 Press and release Initialization Button A 2 Immediately place a finger on the Fingerprint Scanner D Hold finger still 1 beep will be heard recognizing the fingerprint followed by 2 consecutive beeps Remove finger Registration is complete Successful Registration Registration is successful when a total of 3 beeps are heard Unsuccessful Registration 2 short beeps will be heard repeat registration process again 3 To register another fingerprint repeat steps 1 2 4 TEST A REGISTERED FINGERPRINT 1 With safe door open press and release Wake Up Button F Bolts C will extend 2 Press and release Wake Up Button F Place a non registered finger on the Fingerprint Scanner D Bolts will stay extended 3 If t
3. 1 Please write your complete details Name Address Telephone E mail address RMA etc 2 Purchase receipt or Proof of Purchase Original Copy 3 A brief explanation of the defect 4 A Check Money Order of 40 00 to cover inspection shipping and handling Please allow 6 8 weeks for delivery BARSKA will examine and test returned product and repair or replace defective part s or units with new part s or a new unit if necessary within the warranty period Purchaser is required to remit 40 00 to BARSKA for return shipping and handling at time product is returned If repair is required after warranty period expiration purchaser will be charged for replacement parts and return shipping BARSKA Optics shall not be liable for any consequential incidental and or contingent damages whatsoever We will not pay shipping insurance or transportation charges from you to us or any import fees duties and or taxes This warranty supersedes all previous BARSKA Optics warranties BC323 4 13 2013 BARSKA 855 Towne Center Drive Pomona CA 91767 t 888 666 6769 f 909 445 8169 www barska com
4. O NOT disassemble the product For all repairs contact BARSKA Customer Service DO NOT use chemicals or cleaning agents to clean the safe Mounting Holes Actual model may vary 11 MOUNTING INSTRUCTIONS The safe may be mounted to a wall or floor Be aware of the load bearing Failure to do so can result in personal injury and or damage to property Use appropriate tools when performing work and always use eye protection Wall Mounting Do not mount the safe without anchoring to the wall Find the studs in the wall at your desired location Most studs are 16 inches or 24 inches apart Check the wall for concealed wires or pipes Measure the location of the pre set drill holes mark their exact position onto the wall ensuring that the studs or anything else behind will not interfere Drill the appropriate size holes for the anchors you are using Carefully press the anchor into the holes at this time Mount the safe by running screws from inside of the safe and securing to anchors ensure the safe is mounted securely Floor Mounting Use proper drill tools depending on the type of floor you are mounting the safe wood tile or concrete Measure the location of the pre set drill holes mark their exact position onto the floor Drill the appropriate size holes for the anchors you are using Carefully press the anchor into the holes at this time Mount the safe by running screws from inside of the safe an
5. SET TO FACTORY DEFAULT MODE 1 Open safe remove Battery Compartment B cover and all 4 AA batteries 2 Press and release Wake Up Button F a few times until no beeps are heard 3 Press and HOLD the Initialization Button A Re insert batteries on the 4th battery you will hear 1 beep followed by 2 consecutive beeps indicating safe is in Factory Default mode 4 RELEASE Initialization Button A 5 Repeat steps 1 3 if a total of 3 beeps are not heard 6 Restore Battery Compartment B cover 7 All fingerprints stored in the safe have been deleted NOTE The safe is in Factory Default mode ANY fingerprint can open the safe 9 LOW BATTERY WARNING 1 When the door is closed and 3 repetitive beeps are heard it indicates the batteries are low 2 Replace batteries immediately Open safe remove Battery Compartment B cover and all 4 AA batteries Insert 4 new AA batteries and restore Battery Compartment B cover NOTE All registered fingerprints remain stored 10 CARE AND MAINTENANCE To maximize the security and performance of the safe keep Fingerprint Scanner D clean use a dry cloth to remove any smudges or prints off the Fingerprint Scanner after each use Test registered fingerprints every 6 months Keep liquids away from the control panel Spills on the control panel will cause damage and possibly electric shock Secure safe in a proper area to prevent from falling and causing damage or injury D
6. d securing to anchors ensure the safe is mounted securely f BARSKA 1 YEAR LIMITED WARRANTY Biometric Safe BARSKA warrants this new safe to be free of original defects in material and or workmanship under normal use for a period of twelve 12 months from the date product is received by purchaser This warranty does not include damage caused by improper installation or maintenance Damage from misuse abuse accident such as dropping normal wear and tear fire flood or acts of nature Damage from service or repairs other than those performed by BARSKA Labor cost and shipping charges for the removal and replacement of defective parts beyond the initial twelve month warranty period All transportation and shipping charges Removing or altering the seal under any circumstances will automatically void the warranty This warranty is limited to original purchaser and is not transferable This warranty applies only to products purchased in the United States Please email info barska com or call 1 888 666 6769 for Return Merchandise Number RMA before any returns The RMA number must appear on the outside of the shipping package Product must be packed carefully and sturdily in its original packaging to prevent damage in transit and returned freight pre paid to BARSKA OPTICS Repair Department 855 Towne Center Drive Pomona CA 91767 Please include all of the following when returning BARSKA products for service and or replacement
7. he bolts retract with a non registered fingerprint registration was unsuccessful and safe remains in Factory Default mode Repeat steps under FINGERPRINT REGISTRATION 4 Press and release Wake Up Button F Place a registered finger on the Fingerprint Scanner D Bolts will retract 5 CLOSE OPEN SAFE DOOR CLOSE Close door press and release Wake Up Button F Bolts will extend OPEN Press and release Wake Up Button F Place a registered finger on Fingerprint Scanner D Bolts will retract 6 BEEP SOUND OPTIONS Beep OFF Press and HOLD the Initialization Button A until the Indicator Lights E are flashing green RELEASE the Initialization Button Beep ON Press and HOLD the Initialization Button A until the Indicator Lights E are flashing green followed by 1 beep RELEASE the Initialization Button 7 DOOR OPEN ALARM Regardless of the beep sound option chosen either On or Off the door alarm is fixed to beep The alarm is activated when the safe door is open and Bolts C are retracted Within 5 seconds the Indicator Lights E will start to flash green More than 5 minutes the safe will start beeping every 10 20 seconds Close safe door press and release Wake Up Button F to extend the Bolts C to cease the alarm With the safe door open and the Bolts C extended no lights or beeping will be heard 4 13 See reverse side for more information BC339 8 DELETE ALL STORED FINGERPRINTS RE

Download Pdf Manuals

image

Related Search

Related Contents

Audio Pro LV 1  Patient Monitor Manual Contents  INSTALLATION CONNECTION MANUAL  Samsung Galaxy Tab S (8.4, LTE) Керівництво користувача(LL)  Universal Security Instruments BF-1104 Specification Sheet  Imation TK-400  Manuale Sharebot NG (Italiano)  INSTALLATION MANUAL Total Heat Exchanger Heat  SkyDemon User Manual  bajar pdf - Prointec  