1. SPX5 Rear Side View Powering the Unit Connect a power supply within the range of operating voltages of the module 9V to 48V and rated current 500 mA OV 4 5 Watts to the VIN and VIN inputs of the module Connect the F G terminal to your Field Ground to avoid electromagnetic interference and to provide a better protection against power surges Connecting the Serial Ports Follow the following diagram to connect the serial ports RX TX and RX TX are used for RS 485 connections For RS 422 RX TX and RX TX are the receive connection and TX and TX are the transmit connections RX TX RX TX TX Serial Ports Termination Setting Switches Use the termination setting switches at the front of the module to terminate the RS485 RS422 networks The recommended setting of these switches for regular operation is OFF however the two terminal nodes in RS 485 RS 422 networks must have the termination resistor enabled so if the SPX5 is located as the first node or last node of a network turn the termination switch to ON as Low Kiana Denial Low Termination SPX5 Configuration Tool The SPX5 Configuration Tool is the Microsoft Windows based configuration tool for the SPX5 Gateways Requirements The SPX5 Configuration Tool for the IZI Technology SPX5 Gateway requires the following minimum hardware and software components e 1 gigahertz GHz or fa
2. r TECHNOLOGY Smart Ideas Simple Solutions SPX5 MODBUS Industrial Wireless Gateway User Manual Before You Begin Successful application of this module requires a reasonable working knowledge of the SPX5 MODBUS software functionality its connected devices and the application in which the combination is to be used For this reason it is important that those responsible for the technical implementation guarantee that the combination will meet the needs of the application without exposing personnel or equipment to unsafe or inappropriate working conditions This manual is provided to assist the user Every attempt has been made to assure that the information provided is accurate and a true reflection of the product s installation requirements In order to assure a complete understanding of the operation of the product the user should read all applicable documentation on the operation of the connected devices Under no conditions will IZI Technology be responsible or liable for indirect or consequential damages resulting from the use or application of the product Reproduction of the contents of this manual in whole or in part without written permission from IZI Technology is prohibited Information in this manual is subject to change without notice and does not represent a commitment on the part of IZI Technology Improvements and or changes in this manual or the product may be made at any time These changes will be made perio
3. conditions described do not cycle the gateway power for 10 minutes ARE YOU SURE THAT YOU WANT TO CONTINUE WITH THE FIRMWARE UPGRADE 10 During the firmware upgrade all operations of the gateway will stop Make sure that no process or equipment safety will be interfered by this process and press the OK button 11 During the firmware download process do not interrupt it or recycle power to the gateway Doing so may cause equipment damage 12 After the firmware is downloaded the following window will show Download Successful Lua Programming Language Lua has been selected as the scripting language of choice because of its speed compactness ease of embedding and most of all its gentle learning curve These characteristics allow the user to create simple scripts right through to advanced programming solutions that a computing science graduate would relish In other words Lua has all the depth and sophistication of a modern language yet remains very accessible to the non programmer Lua originated in Brazil and has a very active and helpful forum While originally conceived as a scientific data description language its greatest single application area has been computer gaming The characteristics that make it a popular for gaming closely matches those required for data acquisition an efficient scripting machine controlling a fast acquisition engine written in C
4. ancel lt Back Firmware Upgrade of SPX5 New versions of the SPX5 Firmware can be downloaded from the SPX5 Main Support Site http www izitechnology com support spx5 From this site click the Firmware link and download the latest version of the SPX5 firmware to your computer These are the steps to proceed to the firmware upgrade of the SPX5 1 Start the SPX5 Configuration Tool from your Windows Start Menu 4 Back bs Search programs and files p Shut ooa Ela 2 Select the Firmware Download option from the SPX5 Configuration Tool Menu di IZI Technology G7 SPX5 Configuration Tool SPX5 Config Tool File Tools Help Firmwarg Download View D gt eb Page 3 The Select Device window will show up showing all the connected SPX5 Gateways on the network Computer Network Interface IP Address Module Name Serial Number Ethernet 169 254 219 97 J STATION 1 00 60 E9 0B AF 2C 10 0 50 102 SPX5 IP Address SPX5 Temporary IP Address SPX5 Detected Device 4 If the device IP Address is shown in Red like in the picture it means that it is located in an IP Address not accessible to your computer If that is the case continue in step 5 otherwise jump to step 8 5 Right click over the gateway and select Set Temporary IP Module Name Ethernet 169 254 219 97 STATION 1 00 60 E9 0B AF 8C 10 0 50 102 Set Temporary IP Remove Temporary IP 6 In th
5. dically to correct technical inaccuracies or typographical errors Table of Contents BAG TON PERA AA ee estes ses 2 Hardware Descrip tioi LG GAGANA AAO 4 Pacl AG AA eee ee ee eee ee eee eee 4 DEI FET OT BY AA E IKA de eeemesc cue ge E E E 4 FXS Topand BOROM AA AA eerste rere 5 SPX5 Left Side VIEW mama aaahh KAKA aa Kaano 5 BED ION EG NEN AA AA AA AA AA AA 6 SPX5 Rear Side VIEW AA AA AA AA AA 6 Pow NGUNIT AA AN 7 Connecuna Me A PO e E AA 7 Serial Ports Termination Setting SWIICNES ccc sscrecacesaesacasccxcencesniesttvauancncsseetenpatectnetivns estatioxetestvantesustuciascacts 8 SPAS LONNPUTGLION TOOK GAGA AA 9 FR MT SN ama AA AA AA AN 9 Pawang ChE SONN AA AA AA AA 9 Installing the SPX5 Configuration TOON amma nG 9 Pawa Upa PNTA AA AA AA 12 Lua Programming Language AGA AA 18 Hardware Description Package Contents The following components are included in each SPX5 gateway box and they are all required to operate this equipment PartPhoto Quantity SPX5 Gateway Application Port Screw Terminal Adapter 5dBi Omni dual band antenna Power Supply Screw Terminal Adapter SPX5 Front View Antenna 1 Wireless Signal Strength Indicator Module and Serial Port Status Indicators Ethernet Port Antenna 2 SPX5 Top and Bottom View Serial Port 1 Serial Termination Switches Serial Port 2 Power Supply Input SPX5 Left Side View 10253 89 6 535 0 85 0 SPX5 Right Side View
6. e displayed window set an IP Address on the same subnet of the PC and click Set Device Name STATION_1 Serial Number 00 60 E9 0B AF 8C Device IP Address 10 0 50 102 Network Mask 255 255 0 0 Temporary IP 169 254 219 98 Temporary Network Mask 255 255 255 dj 7 Now the Select Device Dialog should show the Temporary IP in green showing that the SPX5 if reachable Module Name Ethernet 169 254 219 97 i STATION_1 00 60 E9 0B AF 8C 10 0 50 102 169 254 219 398 8 Double click the device which firmware wants to be updated After that a dialog will ask you for the firmware file Search for the dld firmware file downloaded from the support web site After this the download dialog will show Device to Download new Firmware Device IP Address 169 254 219 98 Device Name STATION_1 9 Press the Download Button and the following warning screen will show Downloading a new firmware will stop all operations of this Device Do 3 not use the SPCS MODBUS for critical control or protection applications where human or equipment safety relies on the operation of the device An unexpected change of state of the digital outputs may result after a firmware upgrade Failure to follow these instructions can result in death serious injury or equipment damage Loss of communication or power during a firmware upgrade may result in the rejection of the new firmware If the controller firmware upgrade fails due to the
7. ster 32 bit x86 or 64 bit x64 processor e 1 gigabyte GB RAM 32 bit or 2 GB RAM 64 bit e 1GB available hard disk space e A working network card with 10 100 Ethernet e Microsoft Windows 8 Windows 7 Windows Server 2008 R2 Windows Server 2008 Windows Vista Windows Server 2003 with Service Pack 2 or later or Windows XP with Service Pack 3 or later e 1024x768 resolution higher resolution recommended with at least 256 colors e Arecent version of any of the following browsers Google Chrome Firefox or Internet Explorer e Internet connection is recommended during installation Downloading The Software The SPX5 Configuration Tool can be downloaded from the SPX5 Main Support Site http www izitechnology com support spx5 From this site click the Configuration Tool link and download the SPX5ConfigSetup msi file to your computer Installing the SPX5 Configuration Tool Double click the SPX5ConfigSetup msi program and click RUN in the Security Warning window We cant verify who created this file Are you sure you want to run this file tf Name SPX5ConfigSetup Release SPX5ConfigSetup msi Type Windows Installer Package From Z Documents Projects WirelessGateway Softwa Run Cena This file is in a location outside your local network Files from locations you don t recognize can ham your PC Only run this file if you trust the location What s the risk After this the welcome screen of the installa
8. tion tool will come up The installer will guide you through the steps required to install SP5 Configuration Tool on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Gee os ee Follow the following screens by pressing Next The installer will install 5PX5 Configuration Tool to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse Folder fC Program Files x86 IZI Technology LLCSSPX5 Configuration Tool Install SPX5 Configuration Tool for yourself or for anyone who uses this computer Everyone O Just me The installer is ready to install SP5 Configuration Tool on your computer Click Next to start the installation If the following security dialog appears User Account Control FEF OU NI Program name Z Documents Projects Wirel SPX5ConfigSetup msi Publisher Unknown V Show details Change when these notifications appear Press the Yes button to continue with the installation SPX5 Configuration Tool has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework C