TC5V 閥門控制器操作手冊 TC5V Valve Gate Controller User Manual

image

Contents

1. TC5V Module 02 04 L6 08 L pieces Rif L1Blank plate pieces Fr 1B Cabinet H 02 O4 O6 O8 Power cord wiring BIRR 548 3 X 103W 220VactRR G 3m Length E Connection Connection cable 3B E SERERE ER 16 PIN Q Connector assignment Length RIE OStandard 3m OCustomized 282 m EHE Quantity Connector Type asp 9 E Ern Connection Cabinet amm ad Connection Cable F Connector Y aS TIS Connector Connector Mame Housing Hood Hood Housi Q Connector Type EW BE WE Ll Type za Plug Socket Plug E Mum ws paz Li ar ation Ja Single Lever 8823 L b Two Pegs 4 Qty_ Qty ACCESSORIES Air Unit Solenoid valve gika Signal cable f A Sl iE 5m pieces 1 ARICO Technology Co Ltd 15 e os AICO ARICO Technology Co Ltd ie ZS GC HEADQUARTERS 23145 235 1 1 8 8F No 1 Alley 1 Lane 235 Baociao Rd Sindian District New Taipei City 23145 Taiwan TEL 886 2 29101266 FAX 886 2 29159434 www arico tw www arico com tw
2. A oe ARICO ARICO Technology Co Ltd C C to Ti Q quem TC5V FRIEF IB USER S MANUAL Ver TC5V 1 0 2 ARICO Technology Co Ltd reserves the right to make any kind of design or functional modification at any moment without prior notice Please read this instruction carefully before use the instrument For avoid wrong operation to make human injured or machine damage CONTENT Chapter 1 TC5V Valve Gate Controller Module 1 1 Features 1 1 2 Specification Software function 1 1 3 Module specification 1 1 4 Description of operation panel 2 1 5 Operation Flow 5 Chapter 2 Option 2 1 Solenoid Valve MVSE 260 10 2 2 MACP200 Specification 13 2 3 TC5V Controller Order List 15 Chapter 1 TC5V Valve Gate Controller 1 1 zj Hm Bl E E B Et E 2 B m gm E E E 1 3 H BH B ug E Module Feature Multiple Touch off signal options AC220 1 10 DC24 Switch type Multiple output voltage options AC220 110 DC24 Relay MOS Relay Time display is adjustable to the first digit after the decimal point Stopwatch can be either accumulative or countdown Three optional control modes Optional pressure retaining mode M
3. Ltd 9 Chapter 2 Option 2 1 Solenoid Valve MVSE 260 series specification Flow features Secondary pressure Model Bore NO Port size No of port No of position Medium Operating pressure range Proof pressure Effective orifice Ambient temperature Response time voltage Power consumption Available voltage range Insulation class Weight MVSE 260 4E1 8A PT 1 4 5 2 Air 2 12 kgf cm 15 kgf cm 18 mm 5 50 C No freezing 40 ms AC110V 220V 50 60 Hz DC24V AC 6 4 OVA DC 2 5W 10 F class 2559 400 600 800 1000 1200 1400 1600 1800 Flow rate ULE Nuwmin 10 Order example Order example of valve X8 STRE CS Order example of manifold MVSE 260 4E1 X X XXX MVSE 260 5B X E pe Manifold 5B 5 5B for body ported type 3 FE 1 Manifold number 2 4 6 8 amp Voltage AC220 AC220V 50 60 Hz AC110 AC110V 50 60 Hz DC024 DC24V IN OUTHI8 B SE BB Solenoid Valve Dimension MVSA 220 5B Valve Body 22 9 17 Km 3 An U et NR a ee i J D ALY
4. L un i f e E KES ou Ny T LA F e z Bh i c ELI E 67 ARICO Technology Co Ltd 11 MVSA 220 5B Base Please use a soft air hose with a diameter of 89 12 2 2 MACP200 Specification opecification Model Components Bore No Port size Medium Operating pressure range Proof pressure Regulation pressure range Ambient temperature Filtration Lubricating oil capacity Min flow for oil drip Recommended lubricating oil Attachment Weight Flow feature Prima ressure Tkoflem EB YP giomi a py BA o3 ps4 E 295 ps p F a e E d p 23 g 2 o1 51 Bo Bo Flow min AMR ARICO Technology Co Ltd 13 MACP200 MAFR200 MAL200 8A PT 1 4 Air 0 9 9kgf cm 0 0 99MPa 15kgf cm 1 5MPa 0 5 8 5kgf cm 0 05 0 85MPa 5 60 C No freezing Standard 40um Option 5um 25C C 50 min Turbine oil ISO VG32 Pressure gauge bracket 606g Primary pressure fkgffent 100 200 300 400 Flow min ANRI MACP200 Air Regulator Dimensions MACP200 B N 148 7 78 IN Quick male connector included OUT 8 straight connector included Please use a soft air hose with a diameter of 8 9 14 ARICO 2 3 I C5V Controller Order List Customer Name P5 418 MODULE Membrane O Standard O Customize ZR
5. wait for the signal of the next ejection Fig IS BB Signal starts AZE Signal ends First Section Second section Third section Fourth Section B mode Upon receipt of ejection signal run in point shows an OFF status in delay time T1 When delay time T1 ends run in point shows an ON status in start time T2 When start time T2 ends run in point turns off When the pressure retaining function is activated after start time T2 ends turn off run in point and wait until ejection signal ends then start pressure retaining function and stop receiving signals Run in point is in ON status during pressure retaining time When pressure retaining time ends run in point turns off and starts to wait for the signal of the next ejection All sections can set different delay and start times Example 1 Set ejection signal 10 seconds First section delay time 3 seconds start time 4 seconds second section delay time 4 seconds start time 6 seconds Operation Upon receipt of the ejection signal first section run in point starts in 3 seconds second starts after 4 seconds first section run in point turns 4 seconds after starting second section run in point turns off 6 seconds after starting Fig 10 Ejection time 10 seconds Signal starts 8h sk 5 S2 Signal ends ya 3 3 seconds 4 4 s
6. OS Relay extension of working life Mechanical Relay up to 600mA is optional opecification Software function setting level A B AB three control switches Pressure retaining mode switch delay work Pressure retaining delay time setting Pressure retaining time setting Decimal point switch Display mode Module specification Panel measurement 50 176mm Display 7 Section tube 0 4 4 2 Power switch Manual dial type Input power AC220 50 60Hz Trigger voltage Must jump JP AC110 50 60Hz AC220 50 60Hz DC24 Switch DC24 Output power must jump JP AC110 RELAY electronic switch 4VA AC220 RELAY 2A electronic switch 600mA DC24 RELAY electronic switch 4W RELAY 2A electronic switch 600mA either one Keys 5 keys select confirm manual output plus minus time setting Function display lamps A B mode lamp OPEN lamp SIGNAL lamp pressure retaining lamp manual output lamp ARICO Technology Co Ltd 1 1 4 Description of operation panel 1 4 1 Faceplate description ro 8 9 11 Delay time when a transmission is signal is received it displays delay time Activation time when run in point is turned on it displays activation time Activation indication when run in point is turned on the indicator lamp turns on Signal indication when signal is received the indicator lamp turns on Pressure retaining indication when pressure retaining is activa
7. ds run in point turns off When pressure retaining time setting is activated after start time T2 ends run in point shows OFF status in pressure retaining time when pressure retaining delay time ends run in point shows ON status in pressure retaining time when pressure retaining time ends run in point turns off Example Set ejection signal 12 seconds First section delay time 3 seconds start time 4 seconds pressure retaining delay time 3 seconds pressure retaining time 2 seconds second section delay time 4 seconds start time 6 seconds pressure retaining delay time 0 seconds pressure retaining operation time 2 seconds Operation Upon receipt of ejection signal first section run in point starts after 3 seconds and closes after 4 seconds after run in point starts and enters pressure retaining mode after run in point is closed run in point starts after delay 3 seconds and closes after 2 seconds after run in point starts Second section run in point starts 4 seconds after receipt of signal run in point closes 6 seconds after starting and enters pressure retaining mode run in point starts O seconds after it is closed run in point closes 2 seconds after the start Rs fe Eo Pressure reatining Pressure reatining delay time Ee FA Signal starts rr MRA Signal ends First section ee 3 Second section 3 seconds 12 seconds 4 2 4 seconds 6 seconds 2 seconds 12 seconds ARICO Technology Co
8. econds Second section 2 SS 4 4 seconds 6 6 seconds ARICO Technology Co Ltd Example 2 with pressure retaining function Set ejection signal 10 seconds First section delay time 3 seconds start time 4 seconds pressure retaining start time 3 seconds Second section delay time 4 seconds start time 6 seconds pressure retaining start time 3 seconds Operation After ejection signal is received first section run in point starts in 3 seconds second sections starts in 4 seconds first section run in point turns off 4 seconds after starting second section run in point turns off 6 seconds after starting after all section run in points turn off wait for the end of ejection signal enter pressure retaining operation to start run in point turn off 3 seconds and begin to receive signals of the next ejection E FR BROS ESD Fig 10 Pressure reatining Ejection time 10 seconds time 3 seconds 8A Sf B6 Signal starts Sencha First section SS E ml 349 3 seconds 4 seconds 3 seconds second section r 4 seconds 6 seconds 3 seconds I 4 6 3 AB mode applicable to trigger signal models with exterior mechanical switches Upon receipt of the ejection signal run in point shows OFF status in delay time T1 When delay time T1 ends run in point shows ON status in start time T2 When start time T2 en
9. on 1 5 1 Parameter flow chart Range of Delav time A Delay time fiAn manual output 0 Ct G setting 0 999 9 time range Display only 0 999 9 s cannot be set switching options A B AB ai M S ej s Pressure retaining function ON OFF d FT 2s s Pressure retaining delay time range 0 19 9 s IH P PE A i F ae saei Pressure retaining time range 0 19 9 s Decimal oint NO OH Display time mode UP up coun DOWN down count ARICO Technology Co Ltd D 1 5 2 Description of Operating Modes A mode Upon receipt of ejection signal run in point shows a closed status in delay time T1 When delay time ends run in point will show an ON status until the ejection signal ends and all run in points turn off simultaneously Example Ejection time 20 seconds First section delay time 3 seconds Second section delay time 5 seconds Third section delay time 10 seconds Fourth section delay time 1 second Description of operation When the ejection signal is received run in point is in OFF status before reaching the delay time First section run in point starts after 3 seconds Second section run in point starts after 5 seconds Third section run in point starts after 10 seconds Fourth section run in point starts after 1 second Run in point shows an ON status after ejection time ends at the same time 1 4 sections are switched to OFF status and
10. ted lamp will turn on when pressure retaining is operating it flashes on and off Mode indication In A mode A lights up in B mode B lights up in AB mode A amp B light up Up key Sets plus or function Time set Enters delay and activation time setting mode Down key Sets minus or function 10 Function option Enters the setting level for optional functions Manual indication Indication of start of manual output 12 Manual key Press once to turn on manual output Press again to turn off manual output 13 Panel handle 14 Power switch 15 Fix panel Fast key function T press pressure retaining switch for 3 seconds the pressure retaining switch will save the previous setting time 1 4 2 Interior structural diagram 1 Jumper signal input selection short circuit method 2 Fuse l ligo i 1 3 Work Relay VES sese 4 0utput selection Jumper short circuit de method same as first point d p29 5 AC220V input 6 AC220V 110V DC24V Relay output gus m 7 Signal input and grounding wire end EE l Caution when you select short circuit PIN please be careful in regards to the short circuit direction up and down short circuit is the correct direction and each set can only select one ARICO Technology Co Ltd 3 1 4 3 Faceplate appearance and dimension 176 3mm 150 6mm iid 191 8mm 22mm Deviation 5bmm 1 5 Operating descripti