1. _e _ Power group AC out AC in e oe Switched on when generator or shore grid is available BIS o Remote panel Generator Autostart Request PE 24V 20 July 2012 WPC EN GD CONTROL 6 2 DESCRIPTION OF THE MAIN FUNCTIONS 6 2 1 Inverter The WPC is equipped with a high performance inverter which supplies a perfect and very precise sine wave Any unit designed for the 230 V 50 Hz electrical grid may connect to it without any problem up to the rated power out of your WPC The inverter is protected against overloads and short circuits Thanks to the largely over dimensioned performance level loads of up to three times greater than the WPC s rated output can be faultlessly supplied for short periods of use thus allowing motors to be started up without any problem When the WPC is operating the LED ON 43 is glowing When the WPC is in inverter mode the LED AC out 46 is glowing If it flashes the inverter is in load search mode see following chapter Automatic load detection 6 2 2 Automatic load detection In order to save battery energy the WPC inverter stops and automatically goes into load search when the detected load is lower than the sensitivity set by the parameter 1187 It automatically goes back into operation when a power consumer greater than this value demands it The indicator 46 flashes if the inverter is in load search mode which also indicates t
2. 2 4 2 Precautions for using the batteries Lead acid or gel batteries produce a highly explosive gas with normal use No source of sparks or fire should be present in the immediate vicinity of the batteries The batteries must be kept in a well ventilated place and be installed in such a way as to avoid accidental short circuits when connecting Never try to charge frozen batteries When working with the batteries a second person must be present in order to lend assistance in the event of problems Sufficient fresh water and soap must be kept to hand to allow adequate and immediate washing of the skin or eyes affected by accidental contact with the acid In the event of accidental contact of the eyes with acid they must be washed carefully with cold water for 15 minutes Then immediately consult a doctor Battery acid can be neutralised with baking soda A sufficient quantity of baking soda must be available for this purpose Particular care is required when working close to the batteries with metal tools Tools such as screwdrivers open ended spanners etc may cause short circuits Consequently occurring sparks may cause the battery to explode When working with the batteries all metal jewellery such as rings bracelet watches earrings etc must be taken off The current output by the batteries during a short circuit is sufficiently powerful to melt the metal and cause severe burns In all cases the instructions of the battery manufa
3. The WPC will automatically distribute the available power to the charger and the user and supply the balance of power if the load demand exceeds the fixed limit thanks to the current assistance function so called smart boost Due to the current assistance feature the battery can be fully discharged despite the presence of f the grid or the generator The average power consumed by the user must not exceed the power of the source at the risk of discharging the battery This system proves to be a decisive advantage particularly in all mobile systems boats leisure vehicles and service vehicles that are frequently connected to sources with a limited value such as a portable or camping power supply Despite a limited source all the greater power applications downstream of the WPC remain functional Despite a limited source all loads connected downstream the WPC remain functional The system will reduce automatically the charging current from its target value 1138 to 0 according to the current used at the output and the the maximum current available at the input set by the parameter 1107 The greater the current at the output the more the part of the current at the input assigned to charging the battery is reduced If the current exceeds the limit 1107 the WPC will supply the balance current from the battery The wiring of the system cable gauge must take into account this particular function which allow to have the sum of the
4. p 28 2 Temp Sens temperature sensor Only connect the original WhisperPower BTS 01 sensor Double connector for connecting See chapter 4 5 8 p 19 WPC bus peripherals such as the The two termination switches 4 for the RCC PSCP or other WPC units communication bus both remain in position T Switch for terminating the terminated except when both connectors Open communication bus are in use Terminated 10 Li L2 L3 Phase selection jumpers JumperdefaultatpositionL1 terminals Take care with the polarity of the battery and terminals 3 4 10 12 AC Input Connection terminals for the AC See chapter 4 5 7 p 19 13 p generator Note It is imperative that the PE terminal be Generator connected Connection terminals for the AC See chapter 4 5 7 p 19 14 AC Input Grid grid Note It is imperative that the PE terminal be connected 15 16 17 Gen Grid Inv terminals even in the absence of voltage at the input of the inverter Connection terminals for the See chapter 4 5 6 p 19 AC Output device output Only active when Note Increased voltages may appear on the Gen Grid AC input is present terminals even in the absence of voltage at the input of the inverter 8 Protective earth See chapter 3 6 1 p 8 and 4 2 p 13 Connection terminals for the See chapter 4 5 6 p 19 AC Output device output Continuous Note Increased voltages may appear on the 10 July 2012 WPC EN GE ASSEMBLY AND INST
5. The default values of the battery s charge threshold level are shown in fig 3a and specified in the parameter table p 35 If they are not acceptable when compared to the batterys manufacturers specification it is necessary to modify them via the remote control before connecting the voltage sources on the AC input charger WhisperPower is not responsible for default values not corresponding with the recommendations of the manufacturer If the factory settings are modified the new values must be entered on the parameter table on p 35 of this manual The default values proposed by WhisperPower are the usual values for lead acid battery or gel batteries VRLA or AGM The cabling and connection of the installation should only be carried out by an appropriately qualified professional The installation material such as cables connectors distribution boxes fuses etc must be adapted and must conform to the applicable laws and regulations the application under consideration 4 5 5 Earthing the battery One of the two battery conductors can be earthed This may be either the positive or negative pole In all cases the installation must conform to the local regulations and usage or specific standards associated with the application In case of earthing the earthing conductor section must at least be equivalent to the section of the battery conductor The earthing of the equipment must also adhere to these regulations In this case the use of the ad
6. 1159 1161 1167 1187 1188 1189 1190 1191 1194 1195 1198 1199 1200 1246 1247 1248 1249 1250 1251 1252 1253 1254 1255 1256 1258 1259 1260 1261 V cell V cell min V cell 2 2 2 1 30 2 05 Battery maintenance voltage Voltage 1 to allow a new battery cycle Duration of under voltage 1 to allow a new cycle Voltage 2 to allow a new battery cycle Duration of under voltage 2 to allow a new cycle Battery absorption voltage Duration of absorption Current at end of absorption Minimum interval between absorptions Wave max of the battery in charger mode V cell Sensitivity of the charge detection 100 approx 25W Number of pulse load research Time interval between load search pulses Duration of under voltage of battery before disconnection Dynamic compensation for under voltage Battery adaptive low voltage allowed Max voltage for adaptive low voltage Time elapsing before transfer relay opens AC in voltage causing the opening of the transfer relay Immediate open critical threshold for the transfer Auxiliary contact 1 activated by voltage 1 1247 after delays 1248 Voltage 1under which auxiliary contact 1 is activated Delays on voltage 1 to activate auxiliary contact 1 Auxiliary contact 1 activated by voltage 2 1250 after delays 1251 Voltage 2 under which auxiliary contact 1 is activated Delays on voltage 2 to activate auxiliary contact 1 Auxiliary contact 1 activated by voltage 3 1253 after delays
7. live PE protective earth connected to the enclosure of the device Any unused cable gland on the unit must be properly closed If not there is a high risk of intrusion of small animals inside the unit and a risk of damage not covered by warranty 4 5 8 Connecting the communications cables The WPC is equipped with a pair of RJ45 8 connectors that allow information transfer via a communication bus for different consumer types which have the proprietary protocol of WhisperPower In this network all parties in the network are connected in series chain The length of the communication bus cable must not exceed 300 m In a system comprising a single WPC the connection of the WPC remote control may be conducted without stopping the WPC hot plug The communication bus will be used to interconnect other WPC inverters in the case of a multi unit application or to connect other types of users who have the proprietary protocol of WhisperPower In these cases the installation must be switched off using the main ON OFF button 41 p 29 to connect the units via the communication bus The 2 switches for the communication bus termination WPC Bus 4 both remain in position T terminated except when both connectors are in use In this case and only in this case both must be placed in the O open position If one of the two connectors is not in use the two termination switches 14 will be in position T 4 5 9 Connecting the auto
8. transfer relay to close You must increase the input current limit 1107 or authorise the exceeding of this limit 1436 or authorise backup on the source 1126 or disconnect some consumers decrease of loads Voltage is present at the device output Check your cabling correct the fault and start the installation again using a manual control on the button 41 Check the input protection devices H for all the system units The software version of all units in the system must be harmonised Proceed according to the WPC RCC PSCP user manual to upgrade the software Failure of the link between the units Check the presence and the state of the communication cables between units 43 This indicator is glowing continuously when the device is working lt flashes when the equipment is temporarily stopped due to a fault displayed by the indicator 42 or a ON OFF control wired at the Remote ON OFF input 7 The equipment will restart automatically when the conditions that led to the temporary stoppage have gone away In the systems with multiunit s in parallel the indicator 43 blinks 2 times when the WPC is temporarily stopped by the master unit of the concerned phase while this mode is authorized 1547 44 This indicator is glowing continuously when the charger is working and has not yet reached his absorption phase It flashes twice during the absorption phase and once during the floating phase lf
9. voltage coming from the battery as well as the source of AC voltage coming from a generator or grid have been disconnected from the electrical installation Even when the WPC has been disconnected from the supply sources AC and DC a dangerous voltage may remain at the outputs To eliminate this risk you must switch the WPC OFF using the ON OFF button 1 After 10 seconds the electronics is discharged and intervention may take place without any danger All elements connected to the WPC must comply with the applicable laws and regulations Persons not holding written authorisation from WhisperPower are not permitted to proceed with any change modification or repairs that may be required Only original parts may be used for authorised modifications or replacements This manual contains important safety information Read the safety and working instructions carefully before using the WPC Adhere to all the warnings given on the device as well as in the manual by following all the instructions with regard to operation and use The WPC is only designed for indoor use and must under no circumstances be subjected to rain snow or other humid or dusty conditions The maximum specifications of the device shown on the type plate as at fig 1b must be adhered to In the event of use in motorised vehicles the WPC must be protected from dust splash water and any other humid condition It must also be protected from vibration by installing absorbent parts
10. voltage value set by the parameter 1188 is reached The inverter will restart automatically when the battery voltage has reached the restarting threshold 1110 This restarting threshold 1110 can be automatically readjusted if the parameter 1194 is activated in order to better protect the battery against repeated cycling in an almost empty state of charge The restarting threshold is then incremented 1298 up to a maximum value 1195 whenever the LVD low voltage disconnection is reached The restarting threshold will be reset to its initial value when the value of parameter 1307 is reached If the inverter is repeatedly 1304 encountering a low voltage disconnection in a short period 1404 it will stop permanently and will only start again via an operator s manual restart 7 1 3 WPC protection The WPC is protected electronically against overloads short circuit overheating and reverse current cabling of a voltage source on AC out In the event of overload or short circuit at the output the inverter stops for some seconds 1533 1400 and restarts If the inverter is repeatedly encountering this situation 1300 in a short period it will stop permanently and will only start again via an operators manual control If the battery voltage exceeds the value set by the parameter 1121 the inverter stops and starts up again when the voltage is less than 1110 If the WPC is repeatedly encountering this situation 1303 in a shor
11. 0 sec deactivated 10 MAINTENANCE OF THE INSTALLATION With the exception of the periodic checking of connections tightening and general condition the WPC does not require any special maintenance July 2012 WPC EN 31 CONTROL 11 PRODUCT RECYCLING The model of the WPC series conform to the European directive 2002 95 EC on hazardous substances and does not contain the following elements lead cadmium RoHS mercury hexavalent chrome PBB or PBDE COMPLIANT 2002 95 EC To dispose of this product please use the service for the collection of electrical waste and observe all applicable obligations according to the place of purchase 32 July 2012 WPC EN GE COMMENTS OF APPENDIX DRAWINGS 12 EC DECLARATION OF CONFORMITY In accordance with EN ISO 17050 1 2004 The inverter and accessories described in this manual comply with the following directive and standards Dir 2004 108 EEC EN 61000 6 1 EN 61000 6 3 EN 55014 EN 55022 EN 61000 3 2 62040 2 LVD 2006 95 EEC EN 62040 1 1 EN 50091 2 EN 60950 1 signed by Name Dr R E Bosman Technical Director Drachten Date June 2011 July 2012 WPC EN 33 CONTROL AND DISPLAY PARTS FOR THE WPG Gad 13 CONTROL AND DISPLAY PARTS FOR THE WPC FIG 4B See chapter 9 1 p 29 Pos 41 42 43 44 45 46 47 34 Denomination OFF ON Charge AC in AC out Description ON OFF button Light indicator for
12. 1254 Voltage 3 under which auxiliary contact 1 is activated Delays on voltage 3 to activate auxiliary contact 1 Voltage for deactivation of Aux 1 Delays on voltage 1255 to deactivate auxiliary contact 1 Auxiliary contact 1 activated by power 1 Power 1 above which auxiliary contact 1 is activated Duration of power 1 for activating auxiliary contact 1 Auxiliary contact 1 activated by power 2 aN cell ec n n Yes lt lt wn O dp Oo 5 5 dp O SSS si elSiSiS SIE IE Se D O 5 G O O O V cell 2 08 80 90 10 55 Vac ac nn cell 97 5 lt iP cell 3 5 lt 13 SS g 5 5 n V cell es 03 lt V cell min In 2 2 yes 70 min 3 yes Setting NC Factory not changeable en O1 July 2012 WPC EN TABLE OF FACTORY S DEFAULTS PARAMETERS SETTINGS 1262 Power 2 above which auxiliary contact 1 is activated 1263 Duration of power 2 for activating auxiliary contact 1 n 1264 Auxiliary contact 1 activated by power 3 y n 1265 Power 3 above which will be activated auxiliary contact 1 1266 Duration of power 3 for activation of auxiliary contact 1 1286 Output voltage Vac 230 120 1288 Dynamic compensation of the thresholds AUX 1 n 1298 Increment step of the adaptive low voltage method mV cell 1300 Number of overloads permitted before definite stoppage 1303 Number of battery over voltages accepted before final stop 1304 Number of battery
13. Whisper Power Centre Load search Input limited 41 The ON OFF button allows the start up or complete stop of the system In the systems comprising several units each unit is started or stopped individually or with the ON OFF ee button of the WPC RCC PSCP remote control Float Absorbtion Equalize Auto restart Battery low ren Overload oe Overtemp e ee Bat over volt Even when the equipment has stopped dangerous voltages may be present at the WPC input 42 This indicator lights up when the equipment has been stopped manually using the ON OFF button 41 It also allows the cause of an unintentional stoppage of the device to be indicated via the different flashes the imminence of a stoppage or the temporary limitation of its performance The table below describes the type of fault according to the number of flashes on the indicator 42 Indicated alarm Comment 1x Imminent If the device has not yet stopped it stoppage as a is recommended to disconnect all result of low non priority consumers and or start battery voltage up the generator If the WPC has stopped it will restart automatically when the battery voltage has reached the correct value again 1110 It can be restarted manually using the ON OFF button 41 as long as the battery voltage is higher than the critical threshold 1488 See also chapter 7 1 3 p 25 2x Stoppage due to In this event the equipment will overload in the
14. all cases where the WPC input is connected to the grid via a plug connector 4 2 2 Stationary installation The installation may be equivalent to a mobile installation with interrupted neutral In a fixed installation where the neutral is connected to the earth at a single installation point upstream of the WPG it is permissible to carry out a connection of the neutrals in order to preserve an unchanged earthing system downstream independent of the operating mode of the WPC This choice has the advantage of keeping the protection devices downstream of the WPC This connection can be executed according to the next figure or carried out by modifying the parameter 1486 In this case the appearance of the first fault will lead to the installation stopping or the disconnection of the protection devices upstream and or downstream of the WPC Safety is guaranteed by the equipotential bonding and by any RCD circuit breakers placed downstream This connection C is not permitted if a socket is installed upstream of the WPC July 2012 WPC EN 13 CABLING ACIN AC OUT LON LON 4 2 3 Installation with automatic PE neutral switching In certain applications it is desirable to keep the neutral upstream and downstream of the WPC separated C while re establishing the earthing system TN S TT or TNC S in the absence of voltage at the input This functionality is forbidden by default by the parameter 1485 This parameter can be modified b
15. current supplied by the inverter plus the current supplied by the source Le If the system have a 5kW source 22A and a 3 5 kW WPC the available power at the output is 8 5kW In this example the wire gauge must be chosen for 38A Exceeding input limit current If despite the decrease in current from the charger and using the source current assistance the limit is exceeded the transfer relay will remain activated and the source may then be overloaded causing the opening of the protective device upstream Exceeding the limit may be prohibited by the parameter 1436 In this case if the current exceeds the limit 1107 the transfer relay will open and the user then powered exclusively by the inverter as long as the output current exceeds the current limit input If the input current limit is exceeded due to a short circuit downstream the transfer relay will remain activated and the protective device upstream of the WPC H will trip Second value of input current limit The second value of the input limit is activated when AC input is available on the Generator input which activated the command entry This command entry is programmable by the parameters 1566 Use a different value for the maximum current of the AC source and 1567 Second maximum current of the AC source 22 July 2012 WPC EN GD CONTROL The WPC PSCP RCC remote control must be used in order to be able to adapt the value of the Grou current limit if necessar
16. device for the output F will be established at a maximum value equal to the rated current of the inverter or at the maximum value of the protection device at the input H if this is exceeds the rated current of the inverter 18 July 2012 WPC EN GD CABLING An additional earthing terminal 17 is present between the two fastening screws at the bottom of Q the unit It can be used instead of a connection on the input terminals of the device particularly when cable cross sections used at the output do not allow the use of a three wire cable live earth and neutral through the conduit glands of the connection cables of the input and output AC IN and AC OUT or when the earthing of one of the poles of the battery PE required using same or greater cross sections than the battery cable 4 5 7 Connecting the AC supply sources The WPC is intended to be supplied by alternative voltage sources such as the public grid and or a generator Check that the rated voltage of the source corresponds to the rated voltage 34 of the WPC specified on the type plate fig 1b The source must be connected to the input terminals marked AC INPUT 13 with sufficient wire section depending on the power output of the source and protected by a protection device of the appropriate calibre This will be at the maximum equal to the current AC in max 35 specified on the type plate The terminals are marked in the following way N neutral L
17. guaranteed to supply installations used for vital medical care nor any other critical installation carrying significant potential damage risks to people or the environment We assume no responsibility for the infringement of patent rights or other rights of third parties that result from using the inverter WhisperPower reserves the right to make any modifications to the product without prior notification 2 4 WARNINGS AND NOTES 2 4 1 General July 2012 WPC EN 5 GENERAL INFORMATION E gt This manual is an integral part of the device and must be kept available for the operator and installer It must remain close to the installation so that it may be consulted at any time The parameter table available at the end of the manual p 35 must be kept up to date in the event of modification of the parameters by the operator or installer The person in charge of installation and commissioning must be wholly familiar with the precautionary measures and the local applicable regulations When the WPC is running it generates voltage that can be potentially lethal Work on or close to the installation must only be carried out by thoroughly trained and qualified personnel Do not attempt to carry out ongoing maintenance of this product yourself The WPC or the generator connected to it may start up automatically under certain predetermined conditions When working on the electrical installation it is important to be certain that the source of DC
18. input 13 of the device and the current limit 1107 set by the user has not been reached It flashes when this limit is reached see chapter 1 1 1 p 25 This indicator is glowing continuously when an alternative voltage of 230V is present at the device output It flashes when the device is in load search mode due to the absence of users See chapter 6 2 2 p 21 Note The acoustic alarm duration 1565 is factory set at 0 sec and is so deactivated July 2012 WPC EN TABLE OF FACTORY S Go DEFAULTS PARAMETERS SETTINGS 14 TABLE OF FACTORY S DEFAULTS PARAMETERS SETTINGS No of Denomination description Fact Mo config value d val ue 1107 1108 1109 1110 1111 1112 1121 1126 1127 1138 1139 Maximum current of the AC source Under voltage of the empty battery Sub voltage of the charged battery Restart voltage of the inverter after under voltage of the battery Automatic startup at power up Inverter frequency Maximum DC voltage for stopping the WPG Source assistance Smart Boost permitted Grid feeding allowed Battery charge current Battery voltage correction according to the temperature mV C 4 V cell V cell 50 60 2 84 yes No cell risks lt lTi lt lt gt 5 5 NIS 16 D NO DIN l l 5 w O po po po EN 5 Ui ND ol lo D O oli e oO fe kol gt op wn GD Z O 1140 1143 1144 1145 1146 1156 1157
19. make several attempts restart equipment due to 1300 every few seconds and will either a short stop if the overload remains see circuit or too high a chap 7 1 3 p 25 It is vital to load for the eliminate the cause of the overload inverter without restarting Restarting is carried out manually by pressing the button 41 3x Decrease in the This may be due to to great a load rated output of the device due to a too high internal temperature July 2012 WPC EN for the device at too high an ambient temperature or counteracted or obstructed ventilation The power output of the device will therefore be limited to around 50 of the Pnom including in charger mode or Smart Boost mode 29 CONTROL 4x 5x 6x 1X 8x 9x Battery voltage higher than the maximum limit set by the parameter 1121 No transfer Insufficient power from the source Startup prevented due to unwanted voltage at the device output Indicates missing voltage on one of the units of the system in a multi unit configuration Software incompatibility in a multi units system Loss of synchronization between the units Check the cause of this excess voltage The equipment will restart automatically when the voltage falls below the threshold value 1122 see chap 7 1 3 p 25 In this case the WPC remains in operation in inverter mode until the output power decrease below the input limit and does not allow the
20. stoppage of the unit Light indicator showing that the equipment is in operation Light indicator showing that the battery is being charged Light indicator showing the presence of correct and synchronised input voltage Light indicator showing the presence of a voltage at the output Stop acoustic alarm Comments The ON OFF button allows the start up or complete stoppage of the system such as it has been programmed When there are several units in the same system each unit must be started up or stopped individually using this button When the light indicator flashes it indicates the cause of the stoppage of the unit its imminent stoppage or the limitation of its rated power output according to chapter 9 1 p 29 This indicator is glowing continuously when the device is working It flashes when the equipment is at a temporary stop Note The equipment will restart automatically when the conditions that led to the temporary stoppage have gone away This indicator is glowing continuously when the charger is in operation and has not yet reached the absorption phase It flashes twice during the absorption phase and once during the maintenance phase lf Smart Boost mode has been activated it is possible that this indicator will go out temporarily when source backup is required by users See chapter 1 1 1 p 25 This indicator is glowing continuously when an alternative voltage with correct values is present at the AC IN
21. strict application of the instructions appearing in this manual The warranty period for the Whisper Power Centre is 2 years 2 3 1 Exclusion of warranty No warranty claims will be accepted for damage resulting from handling usage or processing that does not explicitly appear in this manual Cases of damage arising from the following causes are notably excluded from the warranty Surge voltage on the battery input for example 48 V on the battery input of an WPC 2000 12 Incorrect polarity of the battery The accidental ingress of liquids into the device or oxidation resulting from condensation Damage resulting from falls or mechanical shocks Modifications carried out without the explicit authorisation of WhisperPower Nuts or screws that have not been tightened sufficiently during the installation or maintenance Damage due to atmospheric surge voltage lightning Damage due to inappropriate transportation or packaging Disappearance of original marking elements 2 3 2 Exclusion of liability The placement commissioning use maintenance and servicing of the WPC cannot be the subject of monitoring by WhisperPower For this reasons we assume no responsibility and liability for damage costs or losses resulting from an installation that does not conform to the instructions defective functioning or deficient maintenance The use of a WhisperPower inverter is the responsibility of the customer in all cases This equipment is neither designed nor
22. voltage For example the model 3500W 24V must have a battery of a minimum capacity of 3500 5 24 730 Ah C 10 Because of the inverter s extreme overload capacity it is often recommended that this value be rounded up An under dimensioned battery may lead to an accidental and undesired stopping of the WPC in the event of high instances of use This stoppage will be due to a voltage that is insufficient on the battery subject to a strong discharge current The battery will be selected with regard to the greatest value resulting from the calculations set out above The battery capacity determines the adjustment of the parameter 1137 battery charge current A value between 0 1 and 0 2 x C batt Ah C10 enables an optimum charge to be guaranteed The method proposed below is strictly indicative and in no way constitutes a guarantee of perfect dimensioning The installer is solely responsible for good dimensioning and installation 4 3 2 Dimensioning the inverter The inverter is dimensioned in such a way that the rated power output covers the power of all the consumers 14 July 2012 WPC EN GD CABLING which will be used at the same time A dimensioning margin of 20 to 30 is recommended to guarantee that the WPC will work well in an ambient temperature of more than 25 C 4 3 3 Dimensioning the generator The power output of the generator must be the same or more than the average daily power Optimally it should be once or t
23. ALLATION 3 6 3 Dipswitch functions To set the behavior of the input switching component of the WPC a dipswitch is available at the input switching board To access it open the connection compartment cover The figure below show the location of the dipswitch Ce pir a en en JRA om SS d Dipswitch location Dipswitch Defaut Prohibit automatic start when grid is available Off 2 Preferred input ON Generator On Off Grid 3 6 3 1 Prohibit automatic start when grid is available Default the generator will automatically start when one of auto start criteria is met It starts even when the is AC grid is connected In some cases the AC grid can supply more power than the generator In this situation it is most likely that starting of the generator is not wanted To prohibit the generator from starting in this situation set the upper dipswitch to the ON position Now the Autostart signal will indicate start only when there is no grid available Refer to the figure above for the position of the dipswitch 3 6 3 2 Preferred input When both AC inputs are available this setting will determine which AC input is passed through for power delivery July 2012 WPC EN 11 CABLING GD 4 CABLING The connection of the WPC inverter charger is an important installation step lt may only be carried o
24. July 2012 WPC EN GD CONTROL Parameters of the battery charger is under the responsibility of the operator Incorrect parameter h that does not correspond to the charging methods of the battery recommended by the manufacturer may be dangerous and or considerably diminish the battery service life If the factory settings are modified it is imperative that the new values be entered in the parameter table p 35 7 1 1 2 Battery charger current setting The maximum charging current can be adjusted by the remote control WPC PSCP RCC The parameter 1138 is part of the basic parameters of the device and must be adjusted at commissioning depending on battery capacity It will be chosen in principle a value between 0 1 and 0 2 x the nominal battery capacity C10 eg 10A for a battery of 100 Ah C10 7 1 2 Battery protection The battery is protected in all cases against deep discharge The indicator 52 flashes once when the battery has reached the disconnection threshold 1108 and the inverter will stop some time after 1190 This threshold can be dynamically corrected 1191 with an advanced algorithm that computes automatically the battery voltage compensation in function of the instantaneous power This correction may also be manually fixed 1532 by setting the low voltage disconnection at full load 1109 These dynamic corrections can be deactivated by setting the parameter 1191 The inverter will stop immediately if a critically low
25. LZ800604 JUV USER MANUAL Whisper Power Center Unit combining inverter battery charger and transfer system WHISPER POWER BV gt i Kelvinlaan 82 TJ o w T 9207 JB Drachten Netherlands Tel 31 512 571550 Fax 31 512 571599 www whisperpower eu V5 July 2012 GD TABLE OF CONTENTS 1 2 5 6 TABLE OF CONTENTS INTRODUCTION ensen co srs cave E E E E T 4 GENERAL INFORMATION eessseeeosssseeossssseossssseeossssecoossesecossseeecssssecoossssecossseecossseeeeossseecossssseeosssseeoosss 4 2 1 Operating MS WINNS EN 4 2 2 OPV SIMI ONS ssaa E E EE E E E E E E E E E 4 2 3 y ANG W N r E E E AE E A 5 293 1 Exclusion OF WANNE lt ascsancsasasansectesanccacesansestesancencesantsctessnasacesuatentesanssacesentsntesasssacesunesatessnsseccsuntententens J 2 3 2 Exclusion of NADI nennen entente 5 2 4 WANS ad DOE S a E E EEE EE EEE E EE EEEE ENEE 5 NE 5 242 PRECAUTIONS tor USING the batteries ccscsccaccinscasceseocsovabensssuzdencencedencgaendeacaaueionsdsugiaeccauedaeetecaaessaaneioarens 6 ASSEMBLY AND INSTALLATION cee sccspcrncerceavsnsannassiessceuayeteueteuiscnapimousnshcuctensesnestabueeet asa cnontaahaxetes tennessee 7 3 1 Handing and MOVING en 7 3 2 OGE ea 7 3 3 MPT AC e En 3 4 MAS CLAN NS LE EEE EE E EE A EE EAE E otstekevoretonevotstekevorstonstoneiekeunss 7 3 5 Fastening ssisoscvareemscvoaneasovoiudeansnemenaewotesieseyssnyssasalasneereamentowebedsas vousvannuntwootncaunwesesskesiswversaninectaamenteunasssnsae
26. N and or AC OUT PE terminals An additional protective earth is located between the two fastening screws at the bottom of the unit 17 j In all cases the PE conductor for the equipment must at least be connected to the PE for all equipment in protection class upstream and downstream of the WPC equipotential bonding It is mandatory that the legislation in force for the application concerned be adhered to 8 July 2012 WPC EN GD ASSEMBLY AND INSTALLATION Tighten of the input 13 and output 14 terminals by means of a no 3 screwdriver The cable sections of these terminals must conform to local regulations All connection cables as well as the battery cables must be mounted using cable restraints in order to avoid any traction on the connection Battery cables must also be as short as possible and the section must conform with the applicable regulations and standards Sufficiently tighten the clamps on the battery inputs 11 and 12 3 6 2 Device connection compartment The units connection compartment must remain permanently closed when in operation It is imperative to close the protection cap on the connection terminals after each intervention in the device After opening check that all sources of AC and DC voltage batteries have been disconnected or put out of service July 2012 WPC EN 9 ASSEMBLY AND INSTALLATION Comment Pos auto start cable Connector for the battery See chapter 8 2 2
27. PC multi inverter system In a system comprising a single WPC the connection of the WPC RCC or WPC PSCP may be conducted without stopping the WPC hot pluggable When connecting an WPC RCC PSCP remote control in a multi unit system it is recommended that all units in the system be stopped and that the communication bus on the device on which the connection is being made be terminated The 2 switches for the communication bus termination Com Bus 4 both remain in position T terminated except when both connectors are in use In this case and only in this case both must be placed in the O open position If one of the two connectors is not in use the two termination switches 14 will be in position T July 2012 WPC EN 2 CONTROL WPC PSCP 8 2 2 BTS 01 temperature sensor The optimal operating voltages for lead batteries vary depending on the temperature A temperature sensor is optionally available to correct the battery voltage and guarantee an optimum charge whatever the battery temperature The correction factor given by the correction of the sensor is set by the parameter 1139 Article no for the temperature sensor including a cable of 3 m BTS 01 Dimensions H x W x D 58 x 51 5 x 22 mm 28 July 2012 WPC EN CONTROL GD 9 CONTROL 9 1 DISPLAY AND CONTROL PANEL The WPC has a ON OFF button and light indicators at the front of the unit allowing clear identification of the operating mode
28. a device from the Whisper Power Centre range You have chosen a high tech device that will play a central role in energy saving for your electrical installation The WPC has been designed to work as an inverter charger with advanced functions which can be used in a completely modular way and guarantee the faultless functioning of your energy system When the WPC is connected to a generator or grid the latter directly supplies the consumers and the WPC works like a battery charger and backup device if necessary The powerful battery charger has an exceptional high efficiency and power factor correction PFC close to 1 It guarantees excellent battery charging in all situations The charge profile is freely configurable according to the type of battery used or the method of usage The charge voltage is corrected depending on the temperature thanks to the optional external sensor The power of the charger is modulated in real time dependent according to the demand of the equipment connected at the WPC output and the power of the energy source grid or generator It can even temporarily backup the source if the consumer demand exceeds the source capacity The WPC continuously monitors the source to which it is connected grid or generator and disconnects Itself immediately if the source is missing disturbed or does not correspond to the quality criteria voltage frequency etc It will then function in independent mode thanks to the integrated invert
29. ae Batterv side fuse Section of The recommended cable cross sections are valid for 9 y cable lt 3m lengths less than 3 m beyond this length it is strongly WPC 4000 48 200A recommended oversize the battery cables WPC 3500 24 300A WPC 2000 12 300A The cable lugs must be carefully fixed and For safety reasons we recommend an annual check ae tightened sufficiently to guarantee minimum on the tightness of all connections For mobile installation the connections should be checked more frequently for tightness loss Insufficient tightening may cause dangerous heating at the connection point 4 5 2 Connecting the battery WPC side Insert the cable glands supplied on the battery cable before tightening the cable lugs Crimp the cable lugs and fasten the cable gland on the device Repeat this for the second battery cable Fix the battery cables to the appropriate connections Battery and Battery The M8 screws must be very well tightened You can insert if required a fuse directly on the positive connection to the battery following the below procedure If cable glands are omitted or if there is no cable is inserted in the cable gland there is a high risk of penetrating of small animals inside the unit and a risk of damage not covered by warranty Any unused gable gland on the unit must be properly closed 4 5 3 Fuse mounting on battery positive pole A fuse delivered with the unit WPC can be mounte
30. ake care to download the latest software version from manufacturer s website and do update all units of the system before the commissioning 8 2 ACCESSORIES 8 2 1 Control centre and display WPC RCC PSCP remote control A WPC RCC PSCP remote display and programming unit can be optionally connected to the WPC via one of the two RJ45 8 type Com Bus 3 connectors These connectors may only be used for connecting a WPCbus compatible accessory excluding any other connection such as LAN Ethernet ISDN etc The WPC RCC PSCP control centre is vital for modifying the parameters of the system It also allows the following functions e Display of function synopsis Display of the measured operational values current voltage power output etc Updating of software or implementation of customised software upload download of inverter charger parameter Updating of inverter parameters Events logging of error message The features of the WPC RCC and the WPC PSCP are the same They only differ in their external appearance The WPC RCC is designed for stand alone operation whereas the WPC PSCP is designed as a combined device Model N WPC RCC Dimensions H x W x D 130 x 120 x 42 2mm WPC PSCP Dimensions H x W x D 195 x 120 x 55mm The two remote control models are delivered with a 15 m cable by default Q article no 60201032 Up to 3 WPC RCC PSCP remote controls can be connected in series on the communication bus of one WPC or an W
31. by the remote control WPC PSCP RCC The parameter 1107 is part of the basic parameters of the device and must be adjusted at commissioning depending on the capacity of the source as follows e If the device is connected to a network the value is sized according to the upstream protective device fuse or circuit breaker or a lower value if desired e If the device connected to a generator the following empirical formula can be used 0 75 x Pnom Uac Since the performance of a generator is highly dependent on the installation the right setting must always be verified for each installation Thermally the generator must be able to continuous supply the load with corresponds to the chosen input limit setting 7 1 1 Battery charger 7 1 1 1 Working principle The battery charger for the WPC is completely automatic and is designed in such a way as to guarantee an optimum charge for the majority of the lead acid or gel batteries Once the transfer relay is activated the battery charger goes into operation and the charge indicator 44 lights up The charging process is at 3 levels I U Uo as described fy figure below this process guarantees optimum charging of the batteries The charging current is given by the parameter 1138 and can be adjusted continuously from O to the nominal value with the help of the WPC PSCP RCC All times and threshold can be adjusted with the remote control unit If the battery voltage is lower than the critical discon
32. c PE neutral switching naaar eeneenennnennnnnnnsseeeeen 14 ALA HgMNNI POLSON erreien aE eE A E e E EE OA e AE aE ea 14 4 3 Recommendations for dimensioning the SYSTEM nunnnnnnsnenenennenennennnenennenenennvnnnnvens 14 Aalt Dimensioning INC DANI siderrerrnnviderrrerarseerverreeoteerseerdenrweoreerenordenreendeerennrdaerewodearennrdan eenden 14 aoe Dimensonhne ne ATO msnnen amen amet ante nnee annen menen 14 4 3 3 DIMENSIONING the generator annannnnserere eeens eversvensnsnnnnnnnsessservsersservrvsnsnsnsnnnnsessseenn 15 4 3 4 Dimensioning the renewable energy SOUrCES nanne ennen eee nennnenennnnnnnenennennnnnnnnnnvens 15 4 4 NVI Kollo LEL En 15 4 5 Connecting Ihe Dalei En 15 4 5 1 Battery cable cross section and DC protective GEVICES cccccccccccccccccccesssssesssssnsseeeeeeeeeeeeeeeees 16 4 5 2 Connecting the battery WPC side nnee eneen eeeneenenneneenennnnennenrnenennennvnvenvnnven 17 4 5 3 Fuse mounting on battery positive Pole nnnnnnnnenneeene nen ene eenen vnenenvnvennnvnnnnven 17 4 5 4 Battery side connection nnnnnnnnnnneneeeneneneneneereervenvenvenvvnnnnvvnnnenvnvvnnvvnvnnvvnvnvvnvnen 17 Bo Banne ine De ra a ae 18 4 5 6 Connecting the consumers at the 230V AC Output nana neeneenn enne nnenvens 18 4 5 7 Connecting the AC supply SOUMCES nnnnnn nennen enen ennneennneenvenennnennnnenennnnnvnvnvnnenensnnnens 19 4 5 8 Conne
33. cting the communications cables 0 ccccccccccccccccccccceeeeessssseeeecccccceeseesssaaaaeessseeeeeeeeeees 19 459 Connecting Te au to start cable sessirnir anre a ER REER ANTARE EEEREN RRAS 19 4 5 10 Connecting the temperature sensor BTS 01 eee eeeeenenneenennennnnnnnnnnnnenens 19 POWERING UP THE INSTALLATION 000 ssssscccccssssscccccsssseccccnsssscccceaesssecceeeesssccceaeesseesseaassseeseoes 19 DESCRIPTION AND FUNCTIONING ccsesssesdsscsascare vexsadsacecduanscosenansansisapssausads evenanavecewaadscesnawasseionsaascaniansas 20 6 1 Setio e r UE EE E E A E A 20 6 2 D scpH northe Main LO ee re REEERE 21 eT WAV e a E E EE 21 6 2 2 Automatic load detection cccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeess 21 July 2012 WPC EN TABLE OF CONTENTS EE AMIST CE FORAY e certains scr asansemscaene torceteuetanan tums E 21 Oa E E E 6 2 E eee E eee eee ere rene 23 6 2 5 Battery protection eeeeeseeeeeeeeeresserrssserrrsressresseerererersersrsreeseseesreseereeeeeereeseseseseseeeeeeeeeseseeeseeeees 25 6206 VP SC en AAE EEN OOO EENE OE OE EOE N 25 7 MULTI UNIT CONFIGURATION in seorsersverntemnsentoonseuntbonmeaewehoreranheeaneradootdennkoansvonbousdenskingstennentenntordesenseans 26 7 1 1 Three phase system wessccactsncasheastesacscnncceneieacesbeaadensaeenaas sededouchadedeuseadadensanasavessedcaceiauendeatendedegssesoduasbe 26 7 1 2 Increas
34. cturer must be followed carefully 6 July 2012 WPC EN GE ASSEMBLY AND INSTALLATION 3 ASSEMBLY AND INSTALLATION 3 1 HANDLING AND MOVING The weight of the WPC is between 35 and 50kg depending upon the model Use an appropriate lifting method as well as help from a third party when installing the equipment 3 2 STORAGE The equipment must be stored in a dry environment at an ambient temperature of between 20 C and 60 C It stays in the location where it is to be used a minimum of 24 hours before being set up 3 3 UNPACKING When unpacking check that the equipment has not been damaged during transportation and that all accessories listed below are present Any fault must be indicated immediately to the product distributor or the contact given at the back of this manual Check the packaging and the WPC carefully Standard accessories e Installation and operating instructions c f Appendix 1 e Mounting plate fig 2a 18 e Cable gland 3 4 INSTALLATION SITE The installation site for the WPC is of particular importance and must satisfy the following criteria e Protected from any unauthorised person Protected from water and dust and in a place with no condensation It must not be situated directly above the battery or in a cabinet with it No easily inflammable material should be placed directly underneath or close to the WPC Ventilation apertures must always remain clear and be at least 20cm from any obstacle tha
35. d directly on the positive connecting pole to the battery respecting the below stacking order The presence of this fuse does not exempt an installation of a protective device fuse or circuit breaker as close as possible of the battery J b a M10 cable lug i b bolt M10 x 30 d c washer E d ceramic washer e fuse Be careful with the orientation of the ceramic washer There is a small lip on one side which must fit into the M10 cable lug s hole 4 5 4 Battery side connection Before connecting the battery carefully check the voltage and polarity of the battery using a voltmeter Incorrect polarity or over voltage may seriously damage the device July 2012 WPC EN 17 CABLING GD Prepare the batteries for connection appropriate battery clamps protection device f cable in good conditions with correctly fitted clamps Fasten the negative cable on to the negative pole of the battery and the positive cable on the open protection device f When connecting the battery a soark may occur when connecting the second pole This spark is normal and due to the charging of the internal filtering capacitor of the WPC even if the unit is halted by the main On Off command 1 As of the connection of the battery it is necessary to check that the parameter values of the WPC are consistent with the recommendations of the battery manufacturer Non conforming values may be dangerous and or seriously damage the batteries
36. ditional earthing screw is recommended 17 which is located at the front of the device between the two lower fastening screws 4 5 6 Connecting the consumers at the 230V AC outputs High voltages may be present on the connection terminals 13 and 14 Make sure that the inverter is deactivated and that there is no AC or DC voltage present on the AC IN terminals and battery terminals before proceeding with the connection The 230V consumers must be connected to the AC OUT 15 and 16 connection terminals with the wire section conforming to the standards with regard to the rated current at the WPC output Distribution must conform to the local standards and regulations and generally be realised via a distribution table The WPC terminals are marked in the following way N neutral L live PE protective earth connected to the enclosure of the device Due to the source assistance function Smart Boost the current at the output of the device may be higher than the rated current of the inverter It is the sum of the current supplied by the additional source and the current supplied by the inverter In this case the dimensioning of the output cables will be carried out by adding the current indicated on the protection device H located on the upstream of the unit to the nominal current of the inverter See also chap 1 1 1 p 25 If the assistance function at the source Smart Boost is not used the size of the protection
37. e battery charger is in operation part of this power will be used for the battery charge The sharing of energy between consumers and the battery charger is adjusted automatically see chap 1 1 1 p 25 The transfer relay will be deactivated when the input voltage no longer satisfies the parameter 1199 or 1432 min and max voltage and frequency at the input or when the current limit 1107 is exceeded if the exceeding of this limit is prohibited 1436 It then passes immediately into inverter mode In this case the loads are supplied exclusively by the battery via the inverter see chap 1 1 1 p 25 This switching always takes place automatically The presence of increased dynamic loads such as pneumatic angle grinders etc may lead to an undesirable opening of the transfer relay due to the weakness of the source To this case a delay in the opening of the transfer relay can be adjusted with the parameter 1198 When the generator stops the change from transfer mode to inverter mode normally takes place without any interruption of the output voltage The interruption will be 40 ms in the event of the immediate loss of input voltage at AC IN provided the UPS mode 1435 is not deactivated 6 2 3 1 Type of detection of AC input loss UPS When the WPC is connected to the public grid or to a generator supplying stable and clean AC voltage the type of detection of input loss 1552 can be selected to fast In this mode p
38. e the abovep 22 it is perfectly normal for the charge current to be lower than the selected current if the limit of the AC input current 1107 is reached b In this event the AC IN indicator 45 flashes The charge current will be limited too if the battery voltage ripple is higher than 0 5V cell If the Smart Boost function is activated 1126 and the power required by the consumer exceeds the power of the source the battery will be discharged c despite the presence of the grid or the generator In this case the LED charge 4 goes out The consumers must ensure that they have average consumption that is less than the power of the source generator or public grid in order to avoid a complete discharge of the battery These situations are set out in the figure below ACin OK I rr E OO EH 1156 en 1140 BS en 1143 ft OB OMO OB 1138 a GND 0 29 Out a bc a d ec a d e Charge cycle example with input current limitation and Smart Boost If the BST temperature sensor is used the voltage adjustment thresholds for the battery are corrected in real time by means of the battery temperature The value of this correction is set by the parameter 1139 in the parameter table p Fout Bladwijzer niet gedefinieerd Much more complex charge profiles or exclusion of the charger can be configured using the WPC PSCP RCC remote control 24
39. ears Options Remote control and programming centre for standalone operation WPC RCC Remote control and programming centre combined with DDC panel WPC PSCP Battery temperature sensor BTS 01 15 1 DIMENSIONS 330 PDE ERE mn In me mn an mn mn En nn nn mn nn mn DD DD ead Oo D DD dh OD TOP du PP PPP DD das Dd Heb DD Ar DD DD de DD LD IP er WP DW CET KOS OP 0 oscrmooooorcsszsoo ro WY 38 July 2012 WPC EN GE TECHNICAL DATA WPC 15 2 TYPE PLATE The model indication operating voltage and currents as well as the serial number of the unit is printed on the type plate which is located on the the left side of the WPC Example type plate for WPC 2000 12 model serial number XXEN 00070 Maximum current in charger nominal current in Idc Charge inv a Rated AC input voltage input range See sect 6 2 3 21 Maximum current at input output See sect 6 2 3 2 p 22 Rated output voltage in inverter mode possible When the transfer relay is adjustment range in inverter mode activated the ac output Vac Out voltage is equivalent to ac input voltage AC Out Maximum AC output current pe Inv max Protection degree according to IEC 60529 July 2012 WPC EN 39 Kelviniaan 82 9207 JB Drachten Netherlands Tel 31 512 571550 Fax 31 512 571599 www whisperpower eu info whisperpower nl
40. er This inverter which has an extremely robust design benefits from WhisperPower s many years of experience and expertise in this area It could supply any type of load without faults enjoying reserves of additional power that is unmatched on the market All your equipment will be perfectly provided with energy and protected from power outages in systems where energy supply is unpredictable unreliable grid or voluntarily limited or interrupted such as hybrid installations on remote sites or mobile installations The parallel and or three phase grid operation of the WPC offers modularity and flexibility and enables optimum adaptation of your system to your energy requirements The WPC RCC PSCP control display and programming centre enables optimum parametering of the system and guarantees the operator continuous control for all important parameters in the installation In order to guarantee perfect commissioning and functioning of your installation please read this manual carefully It contains all the necessary information relating to the functioning of the inverters chargers in the WPC series The setting up of such a system requires special expertise and may only be carried out by qualified personnel familiar with the applicable local regulations 2 GENERAL INFORMATION 2 1 OPERATING INSTRUCTIONS This manual is an integral part of each inverter charger from the WPC series It covers the following models and accessories Inverter charg
41. er WPC 2000 12 WPC 3500 24 WPC 4000 48 Temperature sensor WPC BTS 01 Remote command module WPC RCC WPC PSCP For greater clarity the device is referred to in this manual as WPG unit or device when the description of its functioning applies indiscriminately to different WPC models These operating instructions serve as a guideline for the safe and efficient usage of the WPC Anyone who installs or uses a WPC can rely completely on these operating instructions and is bound to observe all the safety instructions and indications contained The installation and commissioning of the WPC must be entrusted to a qualified professional The installation and usage must conform to the local safety instructions and applicable standards in the country concerned 2 2 CONVENTIONS This symbol is used to indicate the presence of a dangerous voltage that is sufficient to constitute a risk of electric shock This symbol is used to indicate a risk of material damage Q This symbol is used to indicate information that is important or which serves to optimise your system 4 July 2012 WPC EN GI GENERAL INFORMATION All values mentioned hereafter followed by a parameter number indicate that this value may be modified using the WPC remote control In general the default values are not mentioned and are replaced by a parameter number in the following format xxxx The default values for this parameter are specified in the defaults paramet
42. er table p 35 All parameter values modified by the operator or installer must be transferred into the same table Q lf a parameter not appearing in the list advanced parameters has been modified by an authorised person with technical knowledge they will indicate the number of the modified parameter s the specifications of the parameter s and the new value set at the end of the same table All figures and letters indicated in brackets or in square brackets refer to items that can be found in the separate manual Appendix to the installation and operating instructions supplied with the device In this appendix these figures and letters are encircled e The figures in brackets refer to elements belonging to the WPC e The uppercase letters in brackets refer to AC cabling elements e The lowercase letters in brackets refer to battery cabling elements 2 3 QUALITY AND WARRANTY During the production and assembly of the WPC each unit undergoes several checks and tests These are carried out with strict adherence to the established procedures Each WPC has a serial number allowing complete follow up on the checks according to the particular data for each device For this reason it is very important never to remove the type plate which shows the serial number The manufacture assembly and tests for each WPC are carried out in their entirety by our factory in Drachten the Netherlands The warranty for this equipment depends upon the
43. erturbation or lack of voltage of less than 1 millisecond can be detected switching the unit in inverter mode immediately This mode guarantees a zero or maximum of 15 ms transfer time July 2012 WPC EN 21 CONTROL E gt This mode should not be used in presence of highly disturbed utility grid or with a low power generator or a generator supplying a poor quality voltage In that case the parameter 1552 will be set on tolerant In the XTS model this can be selected by positioning the UPS slide switch 20 in off position The tolerance of this mode is adjustable with the parameter 1510 if required The tolerant UPS mode insure a interruption time of max 20 milliseconds In rare cases due to the low quality of the source and if the transfer relay switches too frequently it is possible to further reduce the sensitivity of detection AC input loss of by changing the parameter 1552 to slow via remote control RCC 02 03 In this case the interruption of power will be 40 ms max Q If the WPC is connected to a generator this must have a power at least equal to half of the power of the WPC s to which it is connected 6 2 3 2 Limiting the AC input current Input limit Principle In order to best use the resources available at the input depending on the generator size or the grid output and to protect the source from overload it s possible to adjust the limit of the input current with the parameter 1107
44. es In In 5 Auto 1547 1565 1566 es 1567 3 a o S y er OO O C o S O a a a o S y a To modify the parameters please refer to the operating instructions for the WPC RCC PSCP remote control NC Factory setting not changeable 36 July 2012 WPC EN GD TECHNICAL DATA WPG 15 TECHNICAL DATA WPC WPC model 2000 12 3500 24 4000 48 Inverter 24V 48V 19 34V 38 68V 3500 VA 4000 VA 4000 VA 1 2 1 4 10W Sin wave 230Vac 2 180 245 Vac or Sin wave 120 Vac 2 50 140 Vac 50 Hz adjustable 45 65 Hz 0 05 quartz controlled 60 Hz adjustable 45 65 Hz 0 05 quartz controlled Automatic disconnection then 2 startup attempts Overheating protection Alarm prior to disconnection and automatic restart Battery charger Programmable U Uo equalisation Uo low U periodic 32A 1 50A detection level Adjustable from 50 to 140 Vac Battery control factory value adjustable range with WPC PSCP RCC By number of cycles NA 100 or at fixed intervals 52 weeks 0 32 days July 2012 WPC EN 3 TECHNICAL DATA WPG WPC model 2000 12 3500 24 4000 48 General data Maximum transfer relay current 30A 0 15ms UPS mode 540 330 150 IP21 Dir 2004 108 CE LVD 2006 95 EEC EN 61000 6 1 EN 61000 6 3 EN 55014 EN 55022 EN 61000 3 2 Dir 20 to 55 C Forced from 45 C lt 40 dB lt 45 dB without with ventilation Warranty 2 y
45. hat the AC voltage is present at the output in an intermittent form The detection threshold for the absence of loads can be adjusted according to the parameter range 1187 by means of the WPC PSCP RCC remote control When the parameter is set to O the inverter will still operate even in the absence of any consumer In standby mode the system will thus consume minimal power from the battery see table of technical data p 36 6 2 3 Transfer relay The WPC can be connected to an alternative power source such as a generator or public grid When the voltage at the entry satisfies the voltage 1199 1470 and frequency 1505 1506 parameters the transfer relay will be activated after a delay 1528 This delay may be adjusted extended to allow a fully stabile status of the generator before transfer When the transfer relay is activated the voltage present at the input of the WPC is available at the output for the consumers connected At the same time the battery charger goes into operation When the transfer relay of the WPC is active the voltage at the output of the WPC is equivalent to O that which is present at the input and cannot be influenced or improved by the WPC The consumers are supplied by the source present at the AC IN input via the transfer relay The maximum current of the transfer relay is 30 A This means that the permanent power of the consumers must be a maximum of 11 500 W at 230 V see chap 1 1 1 p 25 If th
46. ing the power by paralleling units ccccccccccccccececcceceeeesssseeeeeececccceeeeeseuaeaaeeseeeeeeeeees 26 Weald C MONE STOM aa a E A E E AT I E 26 7 1 4 Enlargement of an existing installation sss vvvvennnnnnssnnsnnnnseeesereerenssonsnnnsnen 26 1 2 PCC SSS OSS oaan E E E E E R dennen 27 7 2 1 Control centre and display WPC RCC PSCP remote Control ccceesssscsecceeeeceeeeeeeeeeeeeeees 27 7 2 2 BTS 01 temperature SENSOS ccccccssscccccccccceeeessseseesessnaeeeeeeeeeeeeeeeseseeeessessaaeeeeeeeeeceeeeeeeseeeeeeeeas 28 ESS 29 8 1 IS OIAY and COO PANE sakecas tense aos sceeteiepsectessusunsnanssemanen E A aatieaseeess 29 9 MAINTENANCE OF THE INSTALLATION vovo eeoonnooorseeeveeennnsonsseeevvennnnssrrse 31 10 PRODUCT RECYCLING oireeni A EE 32 11 EC DECLARATION OF CONFORMITY oder tenronandertiensendsden a a Ta 33 12 CONTROL AND DISPLAY PARTS FOR THE WPC FIG 4B eeen venen eeeeennnn 34 13 TABLE OF FACTORY S DEFAULTS PARAMETERS SETTINGS eeeeae so voveeeeveeenens 35 14 TECHNIGALEDATA WPG smienten enaties Na Aa eaii 37 14 TECHNICALDATA WEG xtc asec otc acces cca aAA ccna sceanuepens AAEREN 37 14 1 ITN SOS N E A cae E AE EEA E EI E E A A EEN A E A E E 38 12 FO OIC E naasacdieavseactieaseadiaapewictascseacboaceqnctssesaceh cavenucrousaantanees eenderde 39 15 CS ZN 40 July 2012 WPC EN 3 GI INTRODUCTION 1 INTRODUCTION Congratulations You are about to install and use
47. llation regulations in every case The installer is responsible for the conformity of the installation with the applicable local standards 4 2 1 Mobile installation or installation connected to the grid via plug connector When the input of the device is connected directly to the grid via a plug the length of the cable must not exceed 2 m and the plug must remain accessible In the absence of voltage at the input the neutral and live are interrupted thereby guaranteeing complete isolation and protection of the cabling upstream of the WPC The earthing system downstream of the WPC is determined by the upstream earthing system when the grid is present In the absence of the grid the earthing system downstream of the inverter is in isolated mode The safety of the installation is guaranteed by the equipotential bonding The connection link between the neutrals C upstream and downstream of the WPC is not permitted in this configuration This connection type guarantees the optimal continuity for supplying the WPC loads The first isolation fault will not lead to an interruption in the supply If the installation requires the use of a permanent isolation controller this would have to be de activated when the TT grid is present at the WPC input All sockets and protection class devices connected downstream of the WPC must be properly connected to the earth earthed socket The cabling rules above remain valid including in installations in
48. mic compensation See parameter 1532 In configuration with several WPC s each unit is controlled independently using the ON OFF push button 41 When the on off control is given by the remote control it is applied simultaneously to all units 8 1 1 Three phase system Three WPC s of the same voltage can be used and combined in order to establish a three phase grid When 3 WPC s are wired to form a three phase grid the wired phases at the input determine the jumper position for selecting the phase 10 It is vital to determine and select the phase for each WPC If the grid is not available at the input of the master unit phase 1 all the units of the system will switch to inverter mode If only a single phase source is available it must be connected to phase 1 The other two phases will therefore be supplied by the other two working units in inverter mode 8 1 2 Increasing the power by paralleling units Up to three WPC s of same type power and voltage can be wired in parallel in order to increase the system s rated power output In this configuration all the ACin inputs of the same type gen or grid of the WPC must be wired with the same input phase Also the ACout outputs should be wired in parallel The most recent unit according to the serial number in the phase will act as the master and will decide on the operation or suspension of the units in parallel according to the consumer s power demand The yield of the installati
49. nection threshold 1488 operation of the charger will be automatically prevented Only the transfer relay is authorised to operate in this case The battery must then be recharged by an external source up to a voltage higher than the critical disconnection threshold in order to allow the WPC charger to operate July 2012 WPC EN 23 CONTROL The charge cycle programmed by default as shown in the example described in the figure opposite runs automatically The line 28 indicates the development of the battery voltage The lower line 29 indicates the battery current input and output ACin OK The cycle starts with a continuous current charge a adjusted by default according to the parameter 1138 If the ambient temperature is increased or the Fig 3b Simplified charge cycle without input current limitation ventilation blocked the current may be reduced and become lower than the selected current Once the absorption voltage 1156 is reached the cycle passes to voltage adjustment mode d known as the absorption phase the duration of which is set by the parameter 1157 The minimum interval between two absorption cycles is limited by the parameter 1161 At the expiry of the absorption time or if the absorption current is lower than the parameter 1159 the voltage is set to a lower value 1140 This phase e is known as the maintenance or floating phase Due to the limiting function for the input current se
50. nreliable grid In the event of an interruption to the energy supply from the public grid the WPC connected to a battery substitutes the faulty source and enables a support supply to the users connected downstream These will be supplied as long as the energy stored in the battery allows The battery will quickly be recharged at the next reconnection to the public grid The use of the WPC as a UPS must be carried out by qualified personnel who have been checked by the responsible local authorities The diagrams in the appendix are given for information and as a supplement The applicable local standards and regulations must be adhered to 4 1 3 Integrated mobile systems These systems are meant to be temporarily connected to the grid and ensure the supply of the mobile system when this is disconnected from the grid The main applications are for boats service vehicles and leisure vehicles For these purposes the WPC has a double AC input 4 1 4 Multi unit systems Whatever system is selected it is possible to realise systems composed of several units of the same type and the same power output Up to three WPC s in parallel or three WPC s forming a three phase grid or three times two or three WPC s in parallel forming a three phase parallel grid may be thus combined 4 1 5 Distributed Minigrid The implementation of the WPC on top of a distributed minigrid beyond the main building requires special care in choosing the distribution s
51. on is therefore still optimal lt is possible to deactivate the master slave mode with the parameter 1547 In that case the load search mode is disabled installed on each of the 2 or 3 devices connected to the same phase If the power source is limited lf the current of the source per phase is greater than 30A a protective device max 30A must be to 30A only one device is common enough 8 1 3 Combined system lt is possible to combine a three phase system with one or several phases made up of 2 or 3 WPC s in parallel A combination of more than one inverter on only one or two phase is also possible for example its possible to build up one powerful phase for the most single phase consumer and the 2 other phases with only one WPC each for the 3 phase motor application It is therefore possible to combine up to nine WPC s by running three WPC s in parallel in a three phase grid The wiring should be comply with the above paragraphs 8 1 4 Enlargement of an existing installation Only subject to compatibility it is most of the time possible to enlarge an existing installation by adding one or several inverters in parallel or in a threephase configuration The compatibility of the new units must be checked by giving Whisper Power the serial numbers of the inverters in the existing installation 26 July 2012 WPC EN GD CONTROL The inverters belonging to the same system must be equipped with the same software version A T
52. start cable The WPC is able to start the generator automatically when needed To use this function the auto start cable has to be connected between the WPC 1 and the RCC PSCP refer to RCC PSCP manual 4 5 10 Connecting the temperature sensor BTS 01 The temperature sensor BTS 01 is supplied with a 3 m cable fitted with RJ11 6 type plugs It may be connected or disconnected at any time including when the device is in use using the corresponding socket 2 marked TS on the WPC Plug the connectors into the socket 2 until they click in The temperature sensor sleeve may simply be stuck onto the battery or directly next to it The temperature sensor will be recognised automatically and the correction made immediately 5 POWERING UP THE INSTALLATION lt is imperative that the closing cap for the connection compartment be installed and screwed tight before the installation is energised There are dangerous voltages within the interior of the connection compartment July 2012 WPC EN 19 DESCRIPTION AND FUNCTIONING E gt The Power up of the WPC must be carried out in the order given below Any Power off must be carried out in the reverse order A too high or inappropriate battery voltage may seriously damage the WPC For example connecting a 24 V battery to the WPC 2000 12 If the WPC has been connected the wrong way around by accident incorrect polarity of the battery it is highly likely that the protection fuse on the bat
53. t period 1403 it will stop permanently and will only start up again via an operator s manual control A battery voltage greater than 1 66 x the nominal voltage may lead to significant damage or destroy the device Overheating of the WPC Insufficient ventilation increased ambient temperature or obstructed ventilation may lead to overheating of certain internal components of the unit In this case the device will automatically limit its power output as long as this abnormal situation persists The WPC must be protected from reverse polarity by means of an external fuse installed on the battery July 2012 WPC EN 25 CONTROL E gt 8 MULTI UNIT CONFIGURATION Several WPC s can be used in the same system either to create a three phase system or to increase the power output of a single or two phases The implementation of this configuration requires particular precautions and it must be installed and commissioned by qualified personal only When multi unit system is commissioned the software s version of every unit will be automatically checked and units may refuse to start in case of incompatibility If so an upgrade of every units is be required with the PSCP RCC and the last software version available by the manufacturer Read the PSCP RCC user s manual to perform this operation A In Multi units system every WPC in the system shares the same battery bank In multi unit system it is recommended to use the automatic LVD dyna
54. t may affect the ventilation of the equipment e In mobile applications it is important to select an installation site that ensures as low a vibration level as possible 3 5 FASTENING The WPC is a heavy unit and must be mounted to a wall designed to bear such a load A simple wooden panel is insufficient July 2012 WPC EN T ASSEMBLY AND INSTALLATION GE The WPC must be installed vertically with sufficient space around it to guarantee adequate ventilation of the device 200 200 SNNSNNSNANNNNNNNENNSNNSENNSNNSNNENNNSNNNNNSNNNNNNNNNNNN 200 200 200 3 5 1 Fastening Screw on a solid wall concrete or metallic wall the supplied mounting washer using a suitable bolt Hang the WPC unit on the wall using the upper bracket on the backside of the WPC Make sure that the bracket is securely fixed For mobile and marine applications it is also necessary to fix the unit using the bottom mount Use two bolts to secure the bottom mount to the wall lt is imperative to ensure complete and safe fastening of the device A device that is simply hung may detach and cause severe damage In motor vehicles or when the support may be subject to strong vibrations the WPC must be mounted on anti vibration supports 3 6 CONNECTIONS 3 6 1 General recommendations The WPC falls within protection class has a PE connection terminal It is vital that a protective earth is connected to the AC I
55. tances 12V battery bank wiring 12V battery bank with 2Vcell in series and wiring with single and parallel series parallel 12Vcell aL July 2012 WPC EN 15 CABLING 24V battery bank wiring 24V battery bank with 2Vcell in serie and wiring with series and parallel series series parallel 12Vcell 48V battery bank wiring with series parallel 12Vcells 48V battery bank wiring with series 12Vcells 48V battery bank wiring 48V battery bank wiring with 2Vcell in parallel series with 2Vcell in series GGG FERGEERERGEG BSSSee pe NN I a i i El EECEER IEEE EEEEEE EN m m bl Fern D 5 err 5 et et Ma Ka Ka Ka CEE EE EE EEE S PoF Viv PS PS Hve TF SS SS Spr IS IL tet 4 5 1 Battery cable cross section and DC protective devices 16 July 2012 WPC EN GD CABLING The battery cables must be protected by one of the following measures in all cases protection device fuse at each pole protection device fuse on the pole not connected to the earth The battery cables must also be as short as possible lt is always preferable to keep the cable at the negative pole of the battery as short as possible In order to avoid any further loss and protection redundancy A protective device f must be installed as close as possible to the battery and sized according to the below table Ran
56. tery cable may melt and will have to be replaced If such is the case it will be necessary to disconnect all the connections to the WPC including the battery If after replacing the fuse the WPC proves not to work correctly after reconnecting the battery with the correct polarity it will have to be returned to your distributor for repair e Connecting the battery e The WPC is supplied and is ready for operation e Connecting the consumers at the outputs Activate the output protection device F if existing and or press the ON OFF button 41 The light indicator AC out 46 lights up or flashes in the event of an absence of consumers e Activating the input circuit breaker s H If an AC source generator or electrical grid valid in frequency and voltage is present at the AC input the device automatically goes into transfer and will start to charge the batteries The consumers at the output are therefore supplied directly by the power source present at the input Your installation is now in operation If particular parameter or adjustment is required by the system it is recommended to carry this out immediately Adjustments must be made with the WPC RCC PSCP remote control Please refer to the operating instructions for this accessory 6 DESCRIPTION AND FUNCTIONING 6 1 CIRCUIT DIAGRAM Shore grid e p _ Continuous AC out AC in e oe ee 3 5 KW silent power 9 kW start up power Generator 1
57. the Smart Boost mode has been activated this indicator goes out temporarily when source backup is required by users loads 45 This indicator is glowing continuously when an alternative voltage with correct values either in frequency 1112 1505 1506 or in voltage 1199 is present at the AC IN input of the device and the current limit set by the user has not been reached It flashes one time when the current limit at the input 1107 set by the user has been reached In this case the charger current is reduced in order to guarantee priority supply to the users see chap 1 1 1 p 25 If the input current is exceeded nevertheless the WPC goes back to inverter mode transfer relay open and the indicator 42 will keep flashing as long as the user 30 July 2012 WPC EN GD CONTROL current exceeds the limit value of the input current 1107 If the Smart Boost mode see chapter 1 1 1 p 25 is used and the inverter is part of the user supply therefore the battery is discharged the charge indicator 44 will be glowing If grid feeding is allowed 1127 this indicator is blinking 2 times while feeding 46 This indicator is glowing continuously when an alternative voltage of 230V is present at the equipment output It flashes when the device is in load search mode according to chapter 6 2 2 p 21 47 Receipt button to stop the acoustic warning The duration of the acoustic alarm 1565 is factory settled to
58. under voltages permitted before final stop 1307 Reset voltage for adaptive correction V cell 1309 Minimum ACin voltage to authorize battery charging 0 1403 1404 1432 1433 1435 1436 1470 1485 1486 1488 1505 1506 1510 1516 1517 1527 1528 1532 Kind of dynamic compensation Auto Man M Period for counting battery over voltages Period for counting battery under voltages Maximum ACin voltage to switch to inverter mode Adaptation range of the charge current according to the input voltage Immediate detection of input voltage loss UPS Allow to exceed AC input current without opening the transfer relay ACin voltage hysteresis for closing the transfer relay Prohibited ground relay Neutral always connected Critical under voltage of the battery Delta of higher frequency accepted Delta of lower frequency accepted Tolerance of fast detection Auxiliary contact 1 deactivated by floating mode Auxiliary contact 2 deactivated by floating mode Decrease max input limit current with AC In voltage Delay before closing transfer relay 0p lt k Trike ie lie Ie lt lt lt lt S S SS NIN IS P N w D A gt ND ak lt D lt 5 5 un THLE TTP RVRRPEPERPPRETT TP ec 250 13 O1 Vac N a aaa mn mn mm a mn aa mn mn ma mn mn en mn ma SS a mn mn a Ss mn mn SS mn a E mm a a mn a mn a a O mn a mn SS En 10 5 s no ell no 1 5 100 yes no y
59. ut by qualified personnel and in accordance with the applicable local regulations and standards The installation must always comply with these standards Pay attention that connections are completely tightened and that each wire is connected at the right place 4 1 CHOICE OF SYSTEM The WPC may be used in different system types each of which must meet the standards and particular requirements associated with the application or site of installation Only an appropriately qualified installer can advise you effectively on the applicable standards with regard to the various systems and the country concerned 4 1 1 Hybrid type stand alone systems The WPC can be used as a primary supply system for off grid sites where a renewable energy source solar or hydraulic is generally available and a generator is used as backup In this case batteries are generally recharged by a supply source such as solar modules wind power or small hydropower systems These supply sources must have their own voltage and or current regulation system and are connected directly to the battery When the energy supply is insufficient a generator is used as a back up energy source This allows the batteries to be recharged and direct supply to consumers via the WPC transfer relay 4 1 2 Grid connected emergency systems The WPC can be used as an emergency system also known as an uninterruptible power supply UPS enabling a reliable supply to a site connected to an u
60. vorses OO a NG a AA EEE E EA EANA EA A OE E 8 3 6 oli 8 3 6 1 General recOMMENALIONS cccsssssssccccececcecceessssssesssssaaeeeeeeeceeeeeessseeeeseseaaaeeeeeeeeeeeeeseeseeeeeaaas 8 3 6 2 Device connection compartment nnnnnnnsenneneneneneeseneneenveneenenenvnnvensnensnvnnvenvenvnnnnnnnens 7 De OPS VOICI TNC ONS zeer A E tender et eed cctenepa cee cd ee cece AT A A AE EA 1 CABLING gare goa bopper cttw cd espns ccertinsev aap eau omuetras acces taveagnsesnautaonvcetaparevaese es eactegegsnentGanaconvartassaseeuees 12 4 1 POCE Or SV SUSI csasanasesnsciasaanssoasesasavassanascanancqosaeansqssdeaarngsosoeeases ron gussessiasessdacgsssesneesesedacestsesnceessesncesesst 12 4 1 1 Hybrid type stand alone systems nnnnnnnnnneenennene eeen eeennnenenenvennenvnennnvnnnnnnnnnnnnen 12 4 1 2 Grid connected emergency systems nnnnnnnnennneneneeennneenenennsennvennenvnnnenvnnnnnnnnnnnvens 12 41 3 integrated mobile SYSTEMS rrereborsenatersrrdhorerraborwserdhoreevsahorweerdhorwerraborweerdborwerrahorvenrdhorwenrahounenrddoue 12 Eel IMC LIS VS TOMS e 12 AN WISTIDUTEG WMG FIG ssesccescosseuescuesevencoaseuascuasesinncnasauanauasasinnenaseusacuaseunacuasauaneuanasinneuanauaneuanasinncuanauancuanasane 12 4 2 Earnhing Syste seerde 13 4 2 1 Mobile installation or installation connected to the grid via plug connector 13 422 Stalonary WAS AN ANON sessir s 13 4 2 3 Installation with automati
61. wice times this power Thanks to the Smart Boost function see chap 1 1 1 p 25 it is not necessary to over dimension the generator Indeed the loads those are temporarily higher than the power of the generator will be supplied by the inverter Ideally it should not have a power output by phase that is less than half of the power of the WPC s present at this phase The power available downstream of the inverter when the generator is working is the same as the Q sum of the two powers if the Smart Boost function is activated The sum of the currents is limited to a maximum of 30A 4 3 4 Dimensioning the renewable energy sources In a hybrid system the alternative energy sources such as the solar generator wind power and small hydropower should in principle be dimensioned in such a way as to be able to cover the average daily consumption 4 4 WIRING DIAGRAMS The diagrams shown in this document are subsidiary The applicable local installation regulations and standards must be adhered to The elements referred to with an uppercase letter denote the alternate current AC part The elements referred to with a lowercase letter denote the direct current DC part 4 5 CONNECTING THE BATTERY Lead batteries are usually available in 2 V 6 V or 12 V block types In the majority of cases in order to obtain an operating voltage that is correct for WPC usage several batteries must be connected in series or in parallel depending on the circums
62. y for each connection to a limited grid Deactivation of the source assistance function Smart Boost With this feature the source current assistance smart boost can be disabled by setting 1126 Automatic reduction of the current limit input When the device is connected to a low power or variable speed generator like the GV 7i or Belt Power the voltage of the generator may temporarily fall down before it reaches rated power To compensate partially this side effect the WPC has a system of automatic reduction of the input current limit if the voltage drops beyond a threshold set by the parameter 1309 1433 to fall to zero when it reaches the value set by parameter 1309 This avoids overloading the generator and too frequent transition of the transfer relay This feature is also used when a variable power sources is connected to the input of the WPC This is particularly the case of 230Vac alternators like the BeltPower coupled to drive motors whose speed varies These devices have their source voltage decrease depending on the available power A correct setting of thresholds 1309 and 1433 ensures continuous power output with the Smart Boost This feature is by default disabled through 1527 assuming the Grid AC input of the WPC is normally connected to a public network It is standard enabled for the Generator AC input through parameter 1554 Setting the current Input limit The maximum input current can be adjusted
63. y the parameter 1485 via the WPC RCC PSCP remote control This modification must be carried out possessing technical knowledge at the responsibility of the installer and in conformity with the applicable regulations and standards The authorization of this function adherence to the requirements for an earth neutral connection at the source 4 2 4 Lightning protection As per the installation site it is highly recommended to set a protection strategy to protect your installation against lightning The strategies depend on various parameters directly linked to each site and we recommend therefore to deal very professionally with this issue The damages due to lightning are generating most of the time significant costs full replacing of the printed electronic board and are not covered by WhisperPower s warranty 4 3 RECOMMENDATIONS FOR DIMENSIONING THE SYSTEM 4 3 1 Dimensioning the battery The battery capacity is dimensioned according to the requirements of the user that is 5 to 10 times its average daily consumption The discharge depth of the battery will therefore be limited and the service life of the battery will be extended On the other hand the WPC must have a battery capacity that is large enough to be able to take full advantage of the performance of the equipment The minimum capacity of the batteries expressed in Ah is generally dimensioned in the following way five times the rated power output of the WPC the battery
64. ystem WhisperPower recommends a TT distribution for the DC grid as well as for the AC grid The size of the grid increases greatly the exposure of the inverters to atmospheric overvoltages and to non equipotentiality in the grid This is particularly noticeable in the aerial distribution grids In this case a very special care must be taken to well implementing all protection measures of the installation 12 July 2012 WPC EN GD CABLING The IT system is not recommended for the distribution This kind of distribution is most of the time forbidden by the local laws The achievement of low voltage electric system is always subject to local laws and must imperatively be implemented and controlled by qualified and professionally authorized staff WhisperPower accepts no liability for damages due to non confirming installation and to the lack of compliance with the local rules or with the recommendations of this manual 4 2 EARTHING SYSTEM The WPC is a protection class unit which is intended for cabling in a grid type TT TN S or TNC S The earthing of the neutral conductor E is carried out at a sole installation point upstream of the RCD circuit breaker D The WPC can be operated with any earthing system In all cases it is imperative that the protective earth be connected in compliance with the applicable standards and regulations The information notes recommendations and diagram mentioned in this manual are subject to local insta

Download Pdf Manuals

image

Related Search

Related Contents

  Mobile Shower Chair Mobile Shower Chair and Commode and  30 S - Bosch  Informations Copieur/Serveur de documents  L2 User Manual  Billy Goat KD502SPQ User's Manual  0-Journal Grand Ales n°97.indd  L`ÉCONOMIE POLITIQUE DE LA COMMUNICATION  Biostar M7VIG 400 Owner's Manual  Lennox International Inc. WINSLOW PS40 User's Manual  