Home

12/24 Power Supply G2

image

Contents

1. 5 The 12V only build option does not have 24V LEDs 12 24 Power Supply Jor pps Telecom 24 Volt Output 12 Volt Output 1 and 2 3 and 4 5 and 6 EA 1and2 3and 4 5 and 6 bataia 1 AMP GMT 1AMP GMT 1 AMP GMT 1 AMP GMT 1 AMP GMT 1AMP GMT Fig 8 Front panel LEDs lED Status Description 24 Volt 1 2 J 12 Volt 1 2 3 4 ao Fuse Failure on one of the corresponding sensor output power feeds The FA LED under the 24 Volt Output area indicates a fuse BE US Alan failure on the 24 volt outputs while the LED under the 12 Volt area indicates a failure on the 12V outputs Table 1 Back Panel LED Descriptions Power Disconnec Ju DPS Telecom aon Fig 9 Back panel LEDs LED Status Description Off No voltage or polarity is reversed on Power Feed A Solid Green Polarity is correct on Power Feed B Power B Off No voltage or polarity is reversed on Power Feed B FA Fuse Fuse Failure on one of the unit power input Alarm feeds Table 2 Back Panel LED Descriptions 7 Technical Support DPS Telecom products are backed by our courteous friendly Technical Support representatives who will give you the best in fast and accurate customer service To help us help you better please take the following steps before calling Technical Support 1 Check the DPS Telecom website You will find answers to many common questions on the DPS Telecom website at http www dpstele com support Look here fir
2. LEDs Operating Temperature 32 140 F 0 60 C Operating Humidity 0 95 non condensing RoHS 9 6 2 Shipping List Please make sure all of the following items are included with your 12 24 Power Supply If parts are missing or if you ever need to order new parts please refer to the part numbers listed and call DPS Telecom at 1 800 622 3314 Note The Power Supply comes in two build options with and without 24V sensor outputs Each build comes with an appropriate number of fuses and sensor plugs Check your part number to determine your build option 12 24 Power Supply D PK PWRSP 12005 12 24 Power Supply User Manual D OC UM113 03100 23 Rack Ear D CS 325 10A 00 X 2 Two Standard Rack Screws 1 000 12500 06 LE Four 3 8 Ear Screws 1 000 60375 05 12V Only Power Supply D PK PWRSP 12004 19 Rack Ear D CS 325 10A 00 Wall Mount Bracket D CS 532 10A 05 i X 2 Two wall mount bracket screws 2 000 60250 01 X 2 Two Metric Rack Screws 2 000 80750 03 yx 2 Two 5 Amp GMT fuses Input Power 2 741 05000 00 ys x 6 Sensor Power Plug 3x if using the 12V only build 2 820 00862 02 Pads 2 015 00030 00 Mrs Eight 1 Amp GMT Fuses Output power 4x if using the 12V only build 2 741 01000 00 X 2 Two Power Connectors Input Power 2 820 00862 02 3 Installation 3 1 Tools Needed To install the 12 24 Power Supply you ll n
3. eed the following tools Phillips No 2 Screwdriver Small Standard No 2 Screwdriver E 3 2 Mounting Flush mount Rack ears are installed front of the unit with front panel flush to the rack Fig 2 The 12 24 Power Supply can be flush or rear mounted The 12 24 Power Supply mounts in a 19 or 23 rack and can be mounted on the right or left in the flush mount or rear mount locations see Fig 2 19 rack ears 23 rack ears w Fig 3 Rack ear dimensions Fig 4 Rack ear dimensions 4 12 24 Power Supply Back Panel Grounding Dual Power 5 Amp GMT 12V Sensor 24V Sensor Fuse Alarm Lug Feeds Fuses Power Output Power Output Relay Optional Fig 5 Back panel of the 12 24 Power Supply The fuse alarm relay is a normally open relay that closes when a fuse fails You can use the relay to report a fuse failure to an RTU Some models of the 12 24V Power Supply don t come standard with the fuse alarm relay Your build option will determine whether or not your model has a fuse alarm relay Note If you have build option D PK PWRSP 12004 the 12V only build your unit will not have 24V sensor outputs 4 1 Power Connection The 12 24 Power Supply is powered by two screw terminal barrier plug power connectors Fig 6 Screw terminal barrier plugs To connect the unit to a power supply follow these steps 1 Always use safe power practices when making power connections Be sure to rem
4. g such Software is furnished to the End User only under a non exclusive perpetual license solely for End User s use with the Product The Software may not be copied or modified in whole or in part for any purpose whatsoever The Software may not be reverse engineered compiled or disassembled No title to or ownership of the Software or any of its parts is transferred to the End User Title to all patents copyrights trade secrets and any other applicable rights shall remain with the DPS Telecom DPS Telecom s warranty and limitation on its liability for the Software is as described in the warranty information provided to End User in the Product Manual End User shall indemnify DPS Telecom and hold it harmless for and against any and all claims damages losses costs expenses obligations liabilities fees and costs and all amounts paid in settlement of any claim action or suit which may be asserted against DPS Telecom which arise out of or are related to the non fulfillment of any covenant or obligation of End User in connection with this Agreement This Agreement shall be construed and enforced in accordance with the laws of the State of California without regard to choice of law principles and excluding the provisions of the UN Convention on Contracts for the International Sale of Goods Any dispute arising out of the Agreement shall be commenced and maintained only in Fresno County California In the event suit is brought or an attorney i
5. oro DPS Telecom Your Partners in Network Alarm Monitoring 12 24 Power Supply G2 Visit our website at www dpstele com for the latest PDF manual and FAQs March 3 2011 D OC UM113 03100 This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied without prior written consent of DPS Telecom All software and manuals are copyrighted by DPS Telecom Said software and manuals may not be reproduced copied transmitted or used to make a derivative work by either mechanical electronic or any other means in whole or in part without prior written consent from DPS Telecom except as required by United States copyright laws 2011 DPS Telecom Notice The material in this manual is for information purposes and is subject to change without notice DPS Telecom shall not be liable for errors contained herein or consequential damages in connection with the furnishing performance or use of this manual 1 Specifications Fig 1 Use 12 24 Power Supply to distribute power to all your external sensors Dimensions 1 7 H x 17 0 W x 4 34 D Weight 2 5 lbs Mounting 19 or 23 rack or wall mount Power Input 48VDC Normal 36 to 72VDC Current Draw 5 Amps max Fuses 5 Amp GMT for power input 1 Amp for each 12 or 24V power output pair Visual Interface 8 Front Panel LEDs 4 if using the 12 Volt output only build 3 Back Panel
6. ove fuses from the fuse distribution panel as well as the back of the unit before making your power connections 2 Use the grounding lug to connect the unit to earth ground The grounding lug is next to the symbol Insert the eyelet of the earth ground cable between the two bolts on the grounding lug Ground cable not included 3 Insert a battery ground into the power connector plug s right terminal and tighten the screw then insert a battery line to the plug s left terminal and tighten its screw 4 Insert a fuse into the fuse distribution panel and measure voltage The voltmeter should read between 36 and 70VDC 5 The power plug can be inserted into the power connector only one way to ensure the correct polarity Note that the negative voltage terminal is on the left and the GND terminal is on the right 6 Insert fuse into the Power A fuse slot The power LED should be lit green 7 Repeat steps 1 6 for Power B connector 5 12 24 Power Supply Front Panel 24 Volt Output 12 Volt Output Fuses Fuses 24 Volt 12 Volt 12 Volt Fuse Sensor LEDs Sensor LEDs Alarm 24 Volt Fuse Alarm Fig 7 Front panel connections for the 12 24V Model Note If you have build option D PK PWRSP 12004 the 12V only power supply build your unit will not have 24 Volt Output fuses sensor LEDs or fuse alarm 6 Front and Back Panel LED Note These Diagrams reflect LED placement and function for the 12 24V model D PK PWRSP 1200
7. s retained by any party to this Agreement to seek interpretation or construction of any term or provision of this Agreement to enforce the terms of this Agreement to collect any money due or to obtain any money damages or equitable relief for breach the prevailing party shall be entitled to recover in addition to any other available remedy reimbursement for reasonable attorneys fees court costs costs of investigation and other related expenses 10 11 Dependable Powerful Solutions that allow users to monitor larger more complicated networks with a smaller less trained staff pre DPS Telecom Your Partners in Network Alarm Management www dpstelecom com 4955 E Yale Fresno CA 93727 559 454 1600 800 622 3314 559 454 1688 fax
8. st for a fast solution to your problem 2 Prepare relevant information Having important information about your DPS Telecom product in hand when you call will greatly reduce the time it takes to answer your questions If you do not have all of the information when you call our Technical Support representatives can assist you in gathering it Please write the information down for easy access Please have your user manual and hardware serial number ready 3 Have access to troubled equipment Please be at or near your equipment when you call DPS Telecom Technical Support This will help us solve your problem more efficiently 4 Call during Customer Support hours Customer support hours are Monday through Friday from 7 A M to 6 P M Pacific time The DPS Telecom Technical Support phone number is 559 454 1600 Emergency Assistance Emergency assistance is available 24 hours a day 7 days a week For emergency assistance after hours allow the phone to ring until it is answered with a paging message You will be asked to enter your phone number An on call technical support representative will return your call as soon as possible 8 End User License Agreement All Software and firmware used in for or in connection with the Product parts subsystems or derivatives thereof in whatever form including without limitation source code object code and microcode including any computer programs and any documentation relating to or describin

Download Pdf Manuals

image

Related Search

Related Contents

Why Toshiba should be first on your list.  マニュアル強化クラッチキット(18/67)取扱説明書  DS Windows 7 & 8  1 Drücken Sie  42816791 FPE  取扱説明書 - Elcometer  MODE D`EMPLOI    

Copyright © All rights reserved.