UPS-400-600 User Manual
Contents
1. AC Input UPS Output Power Conditioning Low Impedance Power Condition ing optional Efficiency Standard Model Transfer Times Battery amp Charger Audible Noise Safety and Reliability Features Size and Weight Operating Environment Warranty SPECIFICATIONS 95V to 135V 47 to 63 Hz sinusoidal AC 75V to 150V UPS 400LIC amp 6OOLIC 108 to 125 Vig sine wave UPS 400 400 VA 240 W maximum UPS 600 600 VA 400 W maximum 50 or 60 3 Hz user selectable modified Standard models provide 3 way MOV surge suppression and EMI RFI noise filtering UPS 400LI amp 600LI models include low impedance isolation transformers for complete input to output line isolation UPS 400LIC amp 600LIC models include line isolation and wide input voltage range power conditioning 98 or higher during AC operation 90 or higher for LI and LIC options 70 or higher during inverter operation 4 ms typical between AC and inverter UPS 400 has 84 VAh of battery capacity for about 5 minutes of holdup at full load 15 minutes at half load UPS 600 has 120 VAh of battery capacity for about 4 minutes of holdup at full load 13 minutes at half load Optional extended battery models UPS 400X and UPS 600X have battery capacities of 204 VAh doubling or tripling the usual holdup times Less than 40dB at 1 5m ANSI A scale during inverter operation Designed to meet UL CSA IEC standards of safety
2. voltage that powers your equipment However when the utility voltage fails completely or when it is too low to reliably hold up your equipment the UPS takes over supplying clean regulated power generated from its internal batteries to your equipment In addition the models equipped with the LI or LIC options include true isolation and power conditioning for further protection OPERATING INSTRUCTIONS 1 After unpacking the UPS make sure that the power switch in the rear of the UPS is in the OFF position and plug it into a grounded 3 pronged 120V electrical outlet Do not connect anything yet to the outlets on the UPS 2 To ensure that your batteries are fully charged leave the UPS plugged in and turned on for at least four hours before hooking up any equipment to the UPS 3 After at least four hours plug in the equipment you want backed up by the UPS into the AC outlets in the rear of the UPS Make sure that your equipment is initially turned off and that you don t exceed the maximum power rating of your UPS model 240W for UPS 400 and 400W for UPS 600 NOTE A typical IBM compatible PC or Macintosh with color monitor draws 240W or less Older equipment file servers and high end PC workstations with large monitors usually draw more Check your equipment s specifications for exact figures Install only essential equip ment to your UPS WARNING NO LASER PRINTERS EVER 4 Turn on the UPS with the rear
3. ANEL INDICATOR The front panel indicator light monitors the status of the UPS in the following manner TAS 1 Continously ON The UPS is operating on AC power y normal operation The buzzer will be off TE n T 2 Blinking slowly The UPS is operating on battery power AC power failed inverter on The buzzer will beep 3 Blinking rapidly The UPS is operating on battery power and the battery is running low Only a few minutes of holdup time remains The buzzer will beep more rapidly 4 OFF The UPS is turned off or has shut down due to low battery REAR PANEL CONTROLS The Power Switch turns the UPS on or off The Alarm Interface connects to your network file server e g Novell Netware or PC to provide UPS alarm reporting functions See enclosed instructions for network installation Setup switch No 1 is inactive With setup switch No 2 in the OFF position the audible alarm will sound only when the reserve battery is running low as a continuous tone In the ON position the audible alarm will beep when running on battery power SETUP SWITCHES Setting setup switch No 3 to the No Function ONt OFF 2 Audible Alarm ON OFF OFF position reduces the switch over voltage by about 10 Use this switch when the UPS is transferring to battery Power power too often Switch Alarm Setup switch No 4 deter N Interface mines the operating fre A quency of the UPS 50 or St 60H
4. ATE TO STATE tExcluding batteries Battery manufacturer s warranty applies on batteries LIMITATION OF LIABILITY IN NO EVENT SHALL TSI POWER OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION OR OTHER PECUNIARY LOSS ARISING OUT OF THE USE OR INABILITY TO USE THIS TSI POWER PRODUCT EVEN IF TSI POWER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOME STATES DO NOT ALLOW THE LIMITATION OR EXCLUSION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU TSi POWER Operating Instructions UPS 400 amp UPS 600 TSi POWER CORP 1103 West Pierce Avenue Antigo Wisconsin 54409 U S A Phone 715 623 0636 FAX 715 623 2426 Internet www tsipower com e mail sales tsipower com Copyright 1999 TSi Power Corporation All rights reserved TSi Power s ongoing product improvement process makes specifications subject to change Other company s product names herein are for identification purposes only and may be trademarks of their respective companies Uninterruptible Power Supply IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important information for models UPS 400 and UPS 600 that should be followed during installation and maintenance of the UPS and batteries Nomina
5. External fuse protects all AC circuits Internal fuse protects all DC circuits Width 5 12 7 cm Depth 16 40 6 cm Height 7 17 8 cm Weight UPS 400 18 Ibs 8 2 kg UPS 600 20 Ibs 9 1 kg Operating Temperature 0 C to 40 C 32 F to 100 F Relative Humidity 90 non condensing at 25 C Estimated MTBF 12 years excluding batteries Two years limited warranty parts and labor excluding batteries Extended warranty available LIMITED WARRANTY TSi Power warrants this product to be free from defects in materials and workmanship for two 2 yearst from the date of purchase from TSi Power or its authorized representatives TSi Power will repair or at its option replace any defective component s during this warranty period To make a request or claim for service under this limited warranty the original purchaser must return the product in the original shipping container or equiva lent to TSi Power or its authorized distributor accompanied by a written receipt showing the date of purchase dealer s name and both the model name and serial number of the product Warranty does not cover transportation costs Damage by misuse accident or unauthorized tampering of the product is not covered by the warranty NO OTHER WARRANTIES ARE EXPRESSED OR IMPLIED TSI POWER IS NOT LIABLE FOR CONSEQUENTIAL DAMAGES THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM ST
6. l voltage of the battery supply inside the UPS is 12 volts Maximum Operating Ambient Temperature for the UPS is 40 degrees Celsius IMPORTANT NOTICE FOR SERVICING PERSONNEL A Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries B When replacing batteries use the same number and the following type batteries SEALED LEAD CALCIUM C CAUTION Do not dispose of battery or batteries in a fire The battery may explode D CAUTION Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic E CAUTION A battery can present a risk of high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects 2 Use tools with insulated handles Be sure to mail the enclosed warranty registration card so that we may better serve you When you call TSi Power s customer support at 1 800 TSI 3160 please have your unit s model number and serial number located in the rear of the UPS ready at hand INTRODUCTION Your TSi Power uninterruptible power supply model UPS 400 or UPS 600 is designed to provide continuous AC power to your equipment during power outages glitches or brownouts Normally the UPS acts as a filter to reduce the noise and spikes in the utility
7. panel power switch and then your equipment After they ve powered up you may want to test the operation of the UPS by unplugging the power cord of the UPS from the electrical outlet Your equipment should continue operating normally But now the green light of the UPS should blink and the audible alarm should sound indicating that your equipment is being supplied with battery power 6 Plug the power cord back into the outlet Within several seconds the audible alarm will go off and the green light will remain on without blinking Once again your equipment will continue to operate normally 7 Inthe event ofa real prolonged power outage the UPS will continue to operate on battery power until the batteries have only a few minutes of reserve power left In such a case the audible alarm will beep more rapidly and the front panel indicator light will blink more rapidly warning you to save your work and prepare for a shutdown 8 Your UPS may be equipped with a port that allows it to communicate with file servers and workstations for automatic backup amp shutdown Consult the enclosed Network Installation Instructions for more information Estimated Holdup Time Chart hours minutes Load SOW 100W 150W 200W 240W 300W 350W 400W MODEL NO SERIAL NO UPS 400 0 38 0 18 0 11 0 07 0 05 n a n a n a UPS 600 1 00 0 32 0 20 0 13 0 10 0 07 0 05 0 04 FRONT P
8. z Be sure to set it to 3 Switchover Voltage HIGH LOW 4 UPS Output Frequency 60Hz 50Hz TON means the switch is DOWN Battery be the same as your AC Extension power Connector The Battery Extension Connector plugs into an EXT 400 for extended holdup times Refer to UPS the installation instruc Output tions enclosed with EXT Sockets 400 ata m Fuse S u Power E Cord
Download Pdf Manuals
Related Search
Related Contents
Page 4 LG PK950N User's Manual MANUEL D`UTILISATION - Green Light Cycle Ltd.Urban Ryder WMF 10 - Homekit.dk Clicca e scarica il manuale relativo al prodotto selezionato BA-01M Manual - NPI Electronic Instruments EVLED Image VSC User Manual Plush 1280 Instructions / Assembly Copyright © All rights reserved.