Home
AS 248 and AR 169 Quorum Time
Contents
1. press ENTER on the AS 248 Remote to download audit records from the AR 169 Movement to the AS 248 Remote Note The unit unwinds and signals with two double flashes of the red LED when the download is complete 7 Once the audit information is downloaded press ENTER to complete the procedure and return to the main menu Viewing and Printing Audits English only For each event audit records consist of the following information Event date Date performed Type Function performed Type Description Ar AR 169 Movement armed with an opening time M Master code changed U User code changed t Real time clock time set d Real time calendar date set h First record in an AR 169 Movement audit trail unique ID of the AR 169 Movement Number Audit record number Detailed description Event details displayed on the message line Where an AR 169 Movement was armed with an opening time Ar event type the detailed description contains similar but different information For example ID 333333 D 5D 21H 33M 15 Each AS 248 Remote and AR 169 Movement features a unique identification code For the AS 248 Remote au dit record the ID represents the AR 169 Movement programmed For the AR 169 Movement audit record the ID represents the AS 169 Movement The date provided is the programmed opening time in days hours minutes and seconds Event time Time performed displayed using a 24 hour cl
2. 9 Press ENTER to accept the displayed option complete the procedure and return to the main menu 4 3 Changing the Language J1 Use the Date function to change the language of messages displayed on the AS 248 Remote message line Press ON OFF and enter your Master code Use the arrow keys to specify the Code CODE function and press SELECT Use the arrows to display the Country COUNTRY option and press SELECT Use the arrows to display the English US French FRANCE Italian ITALIA Spanish ESPANA or German DEUTSCHLAND language option 5 Press ENTER to accept the displayed option 6 Press ENTER to complete the procedure and return to the main menu 4 4 Changing the Access Codes Q Use the Code function to change the AS 248 Remote s six digit Master and four or five digit User Codes If you enter an incorrect number of digits for the code the change is refused Press ON OFF and enter your Master code factory default is 123456 Use the arrow keys to specify the Code CODE function and press SELECT Use the arrows to display the Master MASTER or User USER code option Press SELECT to accept the displayed option Enter the new code Re enter the new code to confirm it Once the code change has been accepted CHANGE ACCEPTED is displayed press ENTER to continue 8 Press ENTER to complete the procedure and return to the main menu Fons SP OV POD 5 Operations J A Master or User co
3. at a temperature between 41 F and 104 F 15 C and 40 Accessories and Parts Part Part Number AS 248 Infrared Control Unit 117 507519 AS 248 Log Viewer Software and ACTISYS IR WIRELESS INTERFACE Infrared Module 135 509298 8 Technical Characteristics 8 1 AR 169 Mechatronic Movement Electronic G VSTE niaaa AAAA ARA microprocessor with very low power EAE AAA AANA S a consumption Central COCK ceeeeeeeeeeeeeeeeeeeeeetees quartz crystal Communication interface 0 IR 820nm IRDA Memory oo eee eeeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeea non volatile Battery riiin onei a CR2 Lithium 3V 1 Expected battery Life oe 3 years Mechanical Release oo eeeeeeeeeeeeeeeeeeeeaaeeeeeeees accelerated action Release force cc eeeeeeeeeeeeeenneeeeeeeees typically 45 N 5 0 Release time cceeeseeeeeeeeeeeeeeeeeeeees typically 250ms Life CYCIOS cccceeeeeeeeeeeeeeeeeeeeeeeees more than 5 000 DIMENSIONS erosin anaia L x W x H 3 0 75 5mm x 1 5 E AEEA EET 38 5mm x 0 8 19 2mm H with AE ETT winding shaft1 4 34 6mm OF Sy ae black plastic FIXAUON a re e eee iaiia 3 screws M 2 5 standard positions Functions Retrofit oe ecceccececeeecceseeeeeeeeeeeneeeenees most time lock cases on today s market Ilale Ker to EE EE T 3 color light indicator Battery eeen leaten sinini low battery indicator A dittral piini euit iainicicidedute titenin mi
4. view audit records and to upload audit records to a PC for printing To operate the AS 248 Remote use the keypad as follows ON OFF To turn the AS 248 Remote on and off Ten numerals zero to nine To enter a Master or User code Arrow left a To toggle between functions on the main menu the selected function and right icon is identified by the cursor or b To advance one position back left or forward right while editing data SELECT a To select a function from the main or b To toggle between function options ENTER a To accept the displayed value while performing functions or b To return to the previous option or menu After one minute of no keyboard activity the power is turned off automatically oo Infrared transmitter Infrared transmitter Figure 1 AS 248 Infrared control unit 3 3 1 3 2 Installation AR 169 Mechatronic Movement Mounting the AR 169 Movement s The AR 169 Movement is designed to fit or retrofit most time lock case mod els installed in North America Europe and Asia You can use the AR 169 Movement jointly with one or more traditional mechanical movements in stalled in the same time lock case For installation procedures see the time lock manufacturer s instructions Installing the Batteries 1 Unclip and open the battery cover located on the front of the AR 169 Movement 2 Install the CR2 Lithium battery as shown by the markings printed in
5. EL DES Route de Neuchatel 15a CH 2072 SAINT BLAISE Switzerland AS 248 and AR 169 English Quorum Time Lock System User Manual Infrared Control Unit and Mechatronic Movement Espanol Quorum Time Lock System User Manual Infrared Control Unit and Mechatronic Movement Francais Quorum Time Lock System User Manual Infrared Control Unit and Mechatronic Movement Warning The factory default AS 248 Master code is 123456 and User code is 1234 For your security change both access codes and soon as possible once the AR 169s are installed Warning The factory default Master code is 123456 and User code is 1234 For your security both the Master and the User code must be changed Warning The factory default Master code is 123456 and User code is 1234 For your security both the Master and the User code must be changed QUORUM Time Lock System User Manual First Edition A publication of Relhdis SA Route de Neuchatel 15a CH 2072 Saint Blaise Switzerland Printed in Switzerland January 2002 Copyright 2000 by Relhdis SA All rights reserved No part of this book may be reproduced or transmitted in any form or by any means Electronic or mechanical including photocopying recording or by any information Storage and retrieval system without prior written permission from the publisher The information contained in this publication is accurate to the best of Relhdis knowledg
6. Plate Adapter Collar and Fixing Screws 7 2 4 N AS 248 Infrared Control Unit In the event of any malfunction or there is any noticeable difference in prod uct operation return the product to the factory Changing the Batteries Note The AS 248 Remote retains audit information even in the absence of power dead batteries The AS 248 Remote requires two AAA alkaline batteries that last approxi mately two years In the event of low batteries the low battery indicator is dis played at the bottom left hand corner of the screen see Figure 4 While the batteries are replaced the programmed date and time are retained for a period of two minutes If the AS 248 Remote is without battery power for more than two minutes the time is reset to 00 00 and the date is reset to WE 25 DEC 1996 For instructions on how to reset the time and date see chapter 4 System Setup BOW He AUDIT a 10 38 Figure 4 AS 248 main menu with low battery indicator Low battery indicator Replace the batteries as soon as possible Unclip and remove the battery cover located on the back of the AS 248 Remote Replace the two AAA alkaline batteries as shown by the markings printed inside the battery chamber and replace the cover Cleaning The AS 248 Remote does not require any maintenance however the plastic case can be cleaned with a cotton ball moistened with water Storage The AS 248 Remote must be stored
7. R 169 Movement indicates that the next opening time is accepted and that the settings can be modified for a period of 120 seconds The red light indicates the end of this period 7 Once the next opening time is uploaded press SELECT to complete the proce dure and return to the main menu or press ENTER to program another AR 169 Movement 5 2 Performing an Audit ES A Master code is required to perform audit functions Use the Audit function to re trieve view and print AR 169 Movement and AS 248 Remote audit records The AR 169 Movement maintains a 100 event audit trail and the AS 248 Remote maintains a 200 event audit trail even in the absence of power dead batteries Retrieving the AR 169 Movement Audit Use the Audit function to download the AR 169 Movement audit records to the AS 248 Remote Note The recommended distance between the AS 248 Remote and the AR 169 Movement for programming is 6 15cm Press ON OFF and enter your Master code 2 Use the arrows to specify the Audit AUDIT function and press SELECT 3 Use the arrows to display the AR 169 Movement AR 169 option and press SELECT 4 Use the arrows to display the Transfer TRANSFER option 5 Use the winding key the AR 169 Movement insert the key into the time lock casing to engage the AR 169 Movement winding shaft and then turn the key 45 counterclockwise 6 While the green light on the AR 169 Movement is flashing 30 seconds
8. ates the countdown and communicates it to the AR 169 Movement When the next opening time is reached the AR 169 Movements instantaneously unlock the time lock The AS 248 Remote maintains a 200 event audit trail and the AR 169 Movement maintains a 100 event audit trail 1 1 Access Codes One four or five digit User code factory default 1234 plus ENTER and one six digit Master code factory default 123456 are used to access the AS 248 Remote func tions see Figure 1 If you enter an invalid code the AS 248 Remote emits a short beep and after four successive invalid attempts the unit temporarily shuts down for four minutes The following functions are available 2 System Components 2 1 AR 169 Mechatronic Movement AR 169 Movements see Figure 2 download the next opening time from an AS 248 Remote or upload audit records to an AS 248 Remote only while the AR 169 Move ment is wound To wind the AR 169 Movement turn the winding key 45 to the left counterclock wise The AR 169 Movement communicates information using its LED display as follows Flashing green Information can be down or uploaded 30 seconds a Next opening time accepted or b Window to modify settings Flashing yellow 120 seconds No Illumination a Inactive or b Countdown to next opening time in progress Flashing red Movement triggered 2 double flashes Flashing green red Low battery indicator yellow red Solid green Hardwar
9. connecting to a PC serial port to receive audit data from the AS 248 Remote to print archive or view Audit Software eeen 3 5 floppy disk Windows 95 8 3 Declaration of CE Conformity according to 89 336 ECC Manufacturer s Name Manufacturer s Address declares that the product Product Name Model Number Product Options Relhdis SA Route de Neuchatel 15a CH 2072 Saint Blaise Switzerland Quorum Time Lock System AR 169 and AS 248 N A Conforms to the following Product Specifications EMC EN 50081 1 1992 EN 55022 1994 Class B EN 50082 1 1997 IEC 1000 4 2 1995 EN 61000 4 2 1995 8 kV CD 15 kV AD IED 1000 4 3 1995 EN 61000 4 3 1996 80 1000 MHz 20V m 9 Warranty Relhdis warrants to the original buyer of any model AR 169 Mechatronic Movement or AS 248 Infrared Control Unit that it will repair or replace at your option any part of any AR 169 or AS 248 which proves to the reasonable satisfaction of Relhdis to have defects arising from the faulty manufacture of the AR 169 or AS 248 or from defective material or components during a period of one 1 year from the date of shipment of the AR 169 or AS 248 by Relhdis This warranty is valid only if the AR 169 or AS 248 is returned by prepaid transport to Relhdis or our authorized repre sentative before the expiry of the warranty period together with a detailed descrip tion of the alleged defect s Relhdis may at our discretion e
10. de is required to perform programming functions Before pro gramming the next opening time ensure that the AS 248 Remote time and date are set for procedures see chapter 4 System Setup 5 1 Programming the Next Opening Time Use the Program function to set the next opening time for the AR 169 Movement s Once the next opening time is successfully uploaded to the AR 169 Movement the AS 248 Remote emits multiple beeps and displays the number of AR 169 Move ments programmed Note The recommended distance between the AS 248 Remote and the AR 169 Movements for programming is 6 15cm 1 Press ON OFF and enter your Master or User code 2 Master code Use the arrows to specify the Program PROGRAM function and press SELECT Master or User code proceed as follows 3 Optional Press SELECT to specify the hour minute or date value and use the arrows to modify the hour by one hour increments the minute value by five minute increments and the date by one day increments 4 Optional Press ENTER to accept the displayed values 5 Use the winding key to wind the AR 169 Movement insert the key into the time lock casing to engage the winding shaft and then turn the key 45 counterclock wise 6 While the green light on the AR 169 Movement is flashing 80 seconds press ENTER on the AS 248 Remote to upload the next opening time from the AS 248 Remote to the AR 169 Movement Note The flashing yellow light on the A
11. e Specifications are subject to change without notice Table of Contents E a A EEA crest thet ta Pe a al let alla te etl al had td abi bln 2 ds IPTFOOUCTIONG tte te el hh hha od 4 TM ACCOSS COdGS tet EN ENN tte te hie ite ti hal bad bel he Bad a 4 2 System Components 0 c cece ee eeeeceneeeeeeeeeeeeeaaaeeeeeeesseeecaaeeeeees 5 2 1 AR 169 Mechatronic Movement cccccccceeeccecceeeseecaeeeceesaeeeeenaaeeees 5 2 2 AS 248 Infrared Control Unit wo cece c ce eeeceeesse esse eesueeesaeeeeaaes 6 O ANSTAN ATION niet thet cette ec ANEN N EANN TR BEARRA hel heal bad Ral hed NARAVEN YE Y 7 3 1 AR 169 Mechatronic Movement ccccccceseeeceeeeeeeeeaeeeeeesaeeeeeeeaeeess 7 3 2 AS 248 Infrared Control Unit wo cece c ce cecceeeseeeeeseeeesaeeesaeeeeaees 7 A System SetU D tees aaa a a aaa aaa a a aaa arae aaa Aa aa cadet henehed det 8 AA Setting the TME eetarea bene e inae be netna tana tae an aaa aaa aaa kaaa anabuh 8 4 2 Setting the Date eetere tartetan bene beat an aneta tama em ba aa raai aa kaunaa 8 4 3 Changing the Language essssesssseeeeesssisiirrrressssrrrrrnrtnsssrrrrneessne 9 4 4 Changing the Access Codes eeeeeeesseireesseesrrrrrrsrsesrrrrrnnnsssne 9 5r Operations s a ae ra En ache net Pn EEDE ENERE RTENE SA 10 5 1 Programming the Next Opening Time ccceeeeseeeeeeeeeeeeeeeeeee 10 5 2 Performing an Audit ccccccccceecceeeeeeeeeeeeeeecceeeeeeeeeteeecaaeeeeeeeete
12. e error Information cannot be down or uploaded Function Description Required Code Program Used to program the next opening time User or Master Time Used to set the real time clock Master Date Used to set the real time date Master Code Used to change the Master and Used codes Master Audit Used to download view and print audit records Master The User code automatically initiates the Program function The last opening date and time programmed for the current day of the week Monday to Sunday are dis played in the message line The Master code accesses the main menu The last function performed is displayed in the message line For information on how to change the factory default codes see chapter 4 System Setup Program Time Date Code Audit BOW Hg PROGRA 10 36 Figure 0 AS 248 Main menu Message line Real Time line In the event of an AR 169 Movement hardware error the LED displays a solid green light and the movement cannot be wound For details please contact Relhdis technical support Batterv cover Infrared receiver LED Display Infrared transmitter Winding shaft Figure 2 AR 169 Mecatronic Movement 2 2 AS 248 Infrared Control Unit While AR 169 Movements are wound an AS 248 Remote see Figure 3 can upload the next opening time to the AR 169 Movements or download audit records from an AR 169 Movement The AS 248 Remote can also be used to
13. eee 10 6 Troubleshooting amp Technical Support 13 7y WMAINTON ANCE 22 22 2 2 ec seo ate Goes cece a so hee ake ere aoe eee Ga a cnr eon 14 7 1 AR 169 Mechatronic Movement ccccccceseeeeeeeeeeceeeaeeeeeeeaeeeeeeaaes 14 7 2 AS 248 Infrared Control Unit cece cee eccee esse eeesaeeeeaeeeeaeees 15 8 Technical Characteristics 0 ccccccccccccecceeeeeeeeeeeeeeeeeeeeeesaeeeaees 16 8 1 AR 169 Mechatronic Movement cccccccseeeceeceeeeceeeaeeeeeeeaeeeeeeaaes 16 8 2 AS 248 Infrared Control Unit ccc ccc eceeeeceseeeeeeeeeeaeeeeaeeees 17 8 3 Declaration of CE Conformity cccccccceecceseeeeeeeeeeeeeeeetteeeeeeeeteneee 18 9 Warranty nna E E E errr ree 19 Please read and follow all directions carefully Checklist Each AS 248 package Includes the following One AS 248 Input Control Unit Two AAA alkaline batteries 1 Introduction This manual introduces the Quorum Time Lock System a major breakthrough in time lock technology that combines the advanced features of electronics with the dependability of traditional mechanics The system comprises the AR 169 Mecha tronic Movement US Patent Number 5 774 066 and the AS 248 Infrared Control Unit Remote Infrared communication between the AS 248 Remote and the AR 169 Movements allows the transfer of the next opening time and audit records When the next opening time is programmed into the AS 248 Remote the unit auto matically calcul
14. lect to refund the pur chase price of the part affected or to issue a credit if the price remains unpaid Relhdis sells precision made AR 169s pr AS 248s the buyer assumes all risks and Relhdis shall not be liable for any reason if the AR 169s or AS 248s has been sub jected to improper installation improper use improper or inadequate maintenance negligence if any unauthorized modification or alternation is made to the AR 169s or AS 248s or in case of accident For greater certainly any AR 169 or AS 248 not operated in accordance Relhdis printed instructions or operated beyond its rated capacity shall not be covered by this or any other warranty These guarantees are in lieu of and not in addition of any other guarantee of condi tion expressed or implied including without limitation merchantability fitness for a particular purpose or latent defects The buyer releases Relhdis from any liability for any reason other than a beach of its warranty Relhdis is not responsible towards the buyer for any reason other than the beach of his obligations The liability of Relhdis shall in no case including negligence exceed the purchase price of the defective AR 169 or AS 248 nor shall Relhdis be liable for any personal injuries property damage or consequential damages
15. nimum last 100 events Accessories FIXING SCreWS 0ececeeeeeeeeeeeeeeeeeeeeees 3 M 2 5 Winding key ce ceeeeeeeeeeeeeeeeeeeeeeeees universal Adapter collar c cceeeeeeeneeeeeees for Diebold time lock Retrofit plate 0 0 eeeeeeeeeeeeeeeeeees for Diebold time lock Environmental Operating temperature aeee 41 F to 104 F 15 C to 40 C Humidity isis btestesetaddciadiadededadedaetedivedae maximum 80 R H non condensing 8 2 AS 248 Infrared Control Unit Electronic CONT EREA E E E A clock quartz Communication interface 0 IR 820nm IRDA Memory nssssssesssesrsesreesseerrrnnreeerenrrnnrrens nor volatile Battery oo eeeeeeeeee eee aaeeeeeeeeeeeeea AAA alkaline battery 2 Expected battery Life 0 0 2 years varies according to frequency of use Display screen LCD liquid crystal gray reflective Keypad ysr egnene 0 9 ON OFF SELECT ENTER left cursor and right cursor Mechanical Dimensions n se L x W x H 5 9 150mm x 2 6 65mm x 1 1 27mm Weight SE 132 g 0 29 Ibs CASO ENE NE ANA AA AA black plastic Functions Battery it ote eel a aiaihalanatan low battery indicator Audit trail oo eee ceeeneeeeeeeeeeeeeeeneeees minimum last 200 events Environmental Operating temperature ee 41 F to 104 F 15 C to 40 C RUMIA Sakae raged sctecardectcncnangraxenccatel maximum 80 R H non condensing Accessories Infrared Module n se for
16. ock The following table provides examples of audit trail records for the AS 248 Remote All AR 169 Movement audit records are Ar event types The only function that is recorded is the arming of the movement with an opening time For example see event number five On the date 980406 at 11 47 the AR 169 Movement with ID number OAOBOC was programmed with the next opening time of 5 days 21 hours 33 minutes and 15 seconds Event date Detailed description Type Number Event time 961225 MASTER CODE CHANGED m1 09 01 961225 USER CODE CHANGED u2 2 961225 NEW DATE 1998 MAR 5 TIME 11H42M t3 i 961225 NEW DATE 1998 APR 6 TIME 11H44M d4 11 44 980406 ID OAOBOC D 5D 21H 33M 15 Ar5 11 47 Viewing an Audit Use the Audit function to view the AR 169 Movement and AS 248 Remote audit records 1 Press ON OFF and enter your Master code 2 Use the arrows to specify the Audit AUDIT function and press SELECT 3 Use the arrows to display the AR 169 Movement AR 169 or the AS 248 Remote AS 248 audit option 4 Press SELECT to accept the displayed option 5 If you selected the AR 169 Movement audit use the arrows to display the View VIEW option and press SELECT If you selected the AS 248 Remote audit press SELECT Note If no AR 169 Movement audit has been downloaded to the AS 248 the view VIEW option for the AR 169 audit cannot be selected For information see Retrieving the AR 169 Audi
17. s com 7 7 1 Maintenance AR 169 Mechatronic Movement Changing the Batteries Note The AR 169 Movement retains audit information even in the absence of power dead batteries The AR 169 Movement requires one 3V CR2 Lithium battery with an ex pected battery life of three years In the event of low batteries the green red and yellow red lights flash when the AR 169 Movement is wound Replace the battery as soon as possible 1 Unclip and open the battery cover located on the front of the AR 169 Movement 2 Install the CR2 Lithium battery as shown by the markings printed inside the battery chamber and close the cover Cleaning The AR 169 Movement does not require any maintenance however the plastic case can be cleaned with a cotton ball moistened with mineral spirits or a similar cleaning agent A pencil eraser can be used to clean the battery contacts The mechanical parts are lubricated at the factory additional lubri cation is to be avoided and may cause dysfunction Protect the AR 169 Movement against dust and liquids and ensure that it is not installed close to any strong magnetic sources Storage The AR 169 Movement must be stored at a temperature between 41 F and 104 F 15 and 40 Accessories and Parts Part Part Number AR 169 Mechatronic Movement 600169 00 41 Winding Key 600100 00 91 Retrofit Kit for Diebold Time Lock includes AR 169 611169 00 41 Mechatronic movements Retrofit
18. side the battery chamber and close the cover AS 248 Infrared Control Unit Installing the Batteries 1 Unclip and remove the battery cover located on the back of the AS 248 Remote 2 Install the two AAA alkaline batteries as shown by the markings printed inside the battery chamber and replace the cover Note If the AS 248 Remote is without battery power for more than two minutes the time is reset to 00 00 and the date is reset to WE 25 DEC 1996 The first time an AS 248 Remote is turned on after the time is reset a warning message is displayed to indicate that the time and date must be set 4 System Setup Before using the Quorum Time Lock System you must set the AS 248 Remote time and date A Master code is required to perform any of the system setup functions For details on how to change the Master code see section 4 4 Changing the Access Codes 4 1 Setting the Time ae Use the Time function to set the AS 248 Remote real time clock The AS 248 Re mote uses the current time to calculate the AR 169 Movement s next opening time Note If the AS 248 Remote is without battery power for more than two minutes the time is reset to 00 00 1 Press ON OFF and enter your Master code 2 Use the arrows to specify the Time TIME function and press SELECT 3 Use the arrows to display the Time TIME option and press SELECT 4 Press SELECT to specify the hour or minute values and use the arrows to mod ify each value b
19. t in section 5 2 Performing an Audit qv lie aie Nace aaa Use the arrows to display the audit records one by one Press SELECT to view detailed information about the displayed audit re cords and press ENTER to return to the audit records Press ENTER to return to the previous menu Press ENTER to return to the previous menu Press ENTER to complete the procedure and return to the main menu Printing an Audit AS 248 Log Viewer software is available to upload audit records from the AS 248 Remote to your PC for viewer and printing Both AS 248 Remote and AR 169 Movement records can be uploaded To order the latest version of the audit software contact your local RELHDIS dealer Troubleshooting amp Technical Support Problem Possible cause Solution When I press the ON OFF key the AS 248 Remote does not turn on The AS 248 Remote batteries were not installed Install the two AAA alkaline batteries The AS 248 Remote batteries were not installed properly Remove the batteries and reinstall them as shown by the markings printed inside the battery chamber check the polarity The AS 248 Remote batteries are dead Replace the two AAA alkaline batteries The AS 248 Remote functions are not accessible The AS 248 Remote has been turned on but no access code has been en tered Enter your User or Master access code For technical support contact Relhdis by fax at 41 32 756 10 49 or e mail mail relhdi
20. y increments of one 5 Press ENTER to accept the displayed values 6 To modify the time format proceed as follows or press ENTER to complete the procedure and return to the main menu 7 Use the arrows to display the Format FORMAT option and press SELECT 8 Use the arrows or press SELECT to display the 12 hour AM PM or 24 hour 24 option 9 Press ENTER to accept the displayed option complete the procedure and re turn to the main menu Note The seconds are reset to zero 4 2 Setting the Date J1 Use the Date function to set the AS 248 Remote real time calendar The AS 248 Remote uses the current date to calculates the AR 169 Movement s next opening time Note If the AS 248 Remote is without battery power for more than two minutes the date reset to WE 25 DEC 1996 Press ON OFF and enter your Master code Use the arrows to specify the Date DATE function and press SELECT Use the arrows to display the Date DATE option and press SELECT Press SELECT to specify the day year or month value and use the arrows to modify each value by increments of one AON 5 Press ENTER to accept the displayed values 6 To modify the date format proceed as follows or press ENTER to complete the procedure and return to the main menu 7 Use the arrows keys to display the Format FORMAT option and press SELECT 8 Use the arrows or press SELECT to display the month day MM DD or day month DD MM option
Download Pdf Manuals
Related Search
Related Contents
L`acceptabilité de l`emballage pour le produit ss-029cg aerospray ® solución limpiadora para boquillas Bux Bitz and Bytez - hamradio modulation types on compact disc Owners Manual - Cramer Sports Medicine Annexe 1 Users Manual - HDTV Review Olympus Ferrari Digital Model 2004 User's Manual DECT UG Famitel SA70 (D22T) SP Jump Starter &Air Compressor12Ah Rotondo Food Prozessor mit Standmixerfunktion - Migros Copyright © All rights reserved.
Failed to retrieve file