L010858 - PCLIO-0808-BT Users Guide

image

Contents

1. Load User Registers This instruction gives the user the ability to load 4 user registers with values ranging from O to 65 535 Increment User Registers This instruction gives the user the ability to increment any of the 4 user registers by 1 Decrement User Registers This instruction gives the user the ability to decrement any of the 4 user registers by 1 Wait This instruction gives the user the ability to wait a given amount of milliseconds before executing the next instruction ranging from 1 to 65 535 L010858 9 December 2012 Section 3 SignlO Software The SignlO software is a helpful utility that supports Anaheim Automation s line of PCLIO 0808 BT Bluetooth IO modules When connecting the Android device to the PCLIO 0808 BT via a bluetooth virtual Com port the SignlO software can easily perform the following tasks e Exercise and monitor the PCLIO 0808 BT IO Board e Write and edit stored programs for standalone operation e Directly communicate with the PCLIO 0808 BT IO Board Installation Software e The SignlO software and supplementary sample programs can be download directly from the Google Play Store The PCLIO 0808 BT manual can be downloaded from www anaheimautomation com literature php e SignlO is compatible with all versions of Android 2 2 and higher Getting Started 1 Click on the SignlO icon to run the SignlO application 2 Apply power to the PCLIO 0808 BT controller 3 Set the appropriate axis setting b
2. Ordering Information The table below lists the products available at Anaheim Automation that are covered by this manual Consult Anaheim Automation Inc or its representatives for information on the latest product releases Part Number Description PCLIO 0808 BT Featured Bluetooth IO Board AA3264 Class 2 Transformer Input 120 VAC 4 5W Output OVDC 500mA L010858 December 2012 Dimensions rr 50 q jan aodbagod r 1 060 a lt A ann on OOHOHHOHHEHHHEOH ATL LP 6 45 125 i 1 70 70 3 40 Lot 50 D 156 i 4 PLCS 769 Wiring Diagrams PCLIO O808 USB TO POWER SUPPLY 0 P1 7 GND OUT8A Y TO POWER SUPPLY 7 9 12VDC IN oures Q OUT7A 7 USB IN P2 OUT7B Y OUTSA Y out6B 7 o 7 GND OUTSA Y 7 GND OUT5B OUTA 4 o OUTB DINI OUT4A Y 3A 250VAC 30VDC e 7 IN8 OUT 7 gt Y IN2 OUT3A GND OR 5V 2 2 N7 OUT3B 7 2 N3 OUT2A 7 7 IN6 OUT2B 7 o 7 INA OUTIAY o DNS OUTIB 9 L010858 6 December 2012 Terminal Descriptions Position Description Power 8 24VDC Power Input Ground Power Return Position Description Inputs Position Description Outputs EC mn N pon E mn mm DE DE me Connector Descriptions Position Description Power 9 12VDC Power Input This connector is for the USB communication and is labeled USB L010858 T December 2012 Section 2 Functions Inputs All i
3. This context menu selection will turn on the selected output Turn Off This context menu selection will turn off the selected output Current Status This context menu selection will return the status of the selected output L010858 15 December 2012 Program Tab Upload Open Clear Error Set Output Register to 255 Wait 1000 ms Set Output Register to 0 Wait 1000 ms Loop to EEPROM Address 0 10 times End Of Program ADD INSTRUCTION ci O 10 21am 3 FE Set Output Register to O Insert Instruction Above Note To access the Insert Instruction Below program context menu you must press down on the Delete Instruction desired Instruction for an extended amount of time Edit Instruction ca 11 14am This context menu selection will insert an additional instruction above the instructions SAS which activated the context menu This context menu selection will insert an additional instruction below the instructions SN ich activated the context menu i i This context menu selection will delete the instruction which activated the context menu Edit Instruction arie i and replace it with the new selection Delete Instruction This will delete the instruction which activated the context menu L010858 16 December 2012 Open Set Output R Wait 1000 m Simply select the file you wish to open Wait 1000 rr or press Close if you wish to cancel Set Output R Loop to EEPI ci 10 23 1m
4. and heaters For inductive loads it will be necessary to connect a clamping diode refer to the electrical specifications section on page 5 from the output to the power source in order to provide adequate fly back protection If Then Statements The if then statements are conditional based on the values preset in the program The user can either test each individual input or all inputs at once If the input or input register matches the given value or values then the program will execute the next line If the input or input register does not match the given value the program will skip the next line and execute the following line If in Active High an open input is read as a 1 and a grounded input is read as a O vice versa if in Active Low Branching or Goto Statements The Goto instruction will have the program jump to the given label If no label is in the program it will error when trying to send Return from Subroutine This function can be placed anywhere in the program as long as a goto statement has been already executed The program will jump back to the last goto statement encoun tered and execute the next line in the program Inner and Outer Loop The loop instructions allow the user to loop a program a variable number of times The program will loop to the designated label location of the program However the label must always be at a lower line number than the loop instruction itself The user can only nest inner loops
5. input 1 4 be analog however it is not possible to have 2 analog without 1 being analog This compares the user specified voltage level of the input and compares it to actual Analog Equal input If the measured value is less than the specified value then it will execute the next line else skip the next line This compares the user specified voltage level of the input and compares it to actual Analog Greater input If the measured value is greater than the specified value then it will execute the Individual Output Register Outputs L010858 next line else skip the next line This compares the user specified voltage level of the input and compares it to actual Analog Less input If the measured value is less than the specified value then it will execute the next line else skip the next line If ON is selected for the input then the input has been activated as an Interrupt and will Ea run to the desired label If OFF is selected then the input will remain digital The outputs can be turned ON 1 or OFF 0 These outputs can be used to trigger PCL operations relays solenoids etc This sets the outputs as a group by assigning each outputs a value ON 1 or OFF 0 and triggers outputs all at once 18 December 2012 Instruction Set cont Goto For Loops Tab Goto Label Return Send ASCII Inner For Loop Outer For Loop User Register Equal User Register Greater User Register Less User Register
6. max 20 characters or set a Name Last four MAC characters of lO unit Name Name Last 4 MAC Characters Encryption On Encryption Off Output Bet Security Pin Output 2 P nable Encryption Output 3 onfiguration Timer s Output 4 0 2 60 255 Close ts ES Output 6 ci 10 21 mm FE SIE This will set the name of the IO module You can choose to set the name only or set the name plus the last 4 characters of the MAC address Security Pin This will set the security pin which will grant you access to connect to the IO unit Encryption This will either enable or disable 128 bit encryption for transmission You will only be able to edit the bluetooth preferences if you are within the configuration Configuration Timer timer The configuration timer is the time you have to enter the bluetooth preferences after the unit is powered on L010858 12 December 2012 Select Axis OUTPUTS Verify Outputs ca 10 22 1m 3 FE Sets the axis select parameter in the SignlO application 0 99 Define Axis Verify Outputs Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 A A ci 10 22m TE Sets the programmable address in the controller 0 99 L010858 13 December 2012 Inputs Tab Active Low Verify Parameters ca 10 200u 3 F This is a toggle button that will change the active state of all inputs When this button reads Active Low Active Low a grounded signa
7. FE Save As Save As on off Set Output R Wait 1000 m 5 Simply enter the Set Output R name you wish to give you file in the Wait 1000 rr text box and press Loop to EEP Save or Cancel ci O 10 23 FE View Sie This will open up a Popup Window of the program inside of the controller L010858 17 December 2012 Instruction Set These tab sheets allows the user to program functions to be added Upon selection a Popup window will be displayed allowing the user to enter the parameters for that specific command if required Input Output Tab Active Low High If Bit If Reg Active High Low Analog On Analog Equal Analog Greater Analog Less Interrupt Individual Output Register Outputs gt lt gt Cl Be a 4 23 pu 3 This conditional command allows the user to execute the next line of code if the spe cific input triggered matches the given value If the input does not match the next line is skipped This conditional command allows the user to execute the next line of code if the inputs ie triggered match the given value If the inputs do not match the next line is skipped This sets the active state of the inputs If Active Low is selected an input is on if tied to ground If Active High is selected an input is on if tied to 5V This changes the functionality of the first four inputs from strictly digital ON OFF to Analog On analog 0 5 V You can either have input 1 input 1 2 input 1 3 or
8. Increment m os la da Dok A ci O 4 24 pu 3 Goto Command allows the program to jump to the specified label Label Command inserts a label for goto and loop commands Return Command will return to the last goto and execute the next line of code Send ASCII This command will send up to 20 characters out of the unit at a Baud rate of 38 400 bps 8 Data bits No Parity 1 Stop bit and No Flow Control Command allows a sequence of commands to be looped a specific number of times to a label This aa ee label must be before the inner loop command This command can be used within an outer loop O reL Command allows a sequence of commands to be looped a specific number of times to a label This P label must be before the outer loop command This command cannot be used within an inner loop This command compares the current status of the selected user register with the user defined value If the current value of the selected user register is equal than the user defined value then the next line is executed else skip the next line This is accurate up to 800 mV User Register Equal This command compares the current status of the selected user register with the user defined value If the current value of the selected user register is greater than the user defined value then the next line is executed else skip the next line User Register Greater This command compares the current status of the selected user register with the user defin
9. PCLIO 0808 BT Bluetooth Controlled lO Board User s Guide l al i Pu jF a Ujj E ki K MR d outa ERR BUT ki e LIN EMITIR a g a gt gt Es a Em L UTOMATION 910 East Orangefair Lane Anaheim CA 92801 e mail info Danaheimautomation com website www anaheimautomation com paises ANAHEIM AUTOMATION INC 714 992 6990 fax 714 992 0471 L010858 December 2012 Table of Contents Section 1 Introduction anida 3 Describa is 3 Methods Of GON WANGA WO AVE aaa 4 DIUGIOOtN TI TAN S sannara a e a e ke ae n e a ke a tk e a a e are 4 POUS SO ciccia 4 Saus LED ia it tia iaa 4 Techhical SUPPORT A Ge 4 EISCHIEIJS DECHICAU ON Sey y tak tat bal st ot se aa e ao ia oo 5 Ordering NO ANN A WO LI das RN TR RN e e e e ka A 5 DIMENSIONS k k UR n be e a a a e ka ka ke bo tt A ii 6 An aa Rf a a 6 Terminal D SEN P WON S ret sy kt e kata a rati aj a a kot A na 7 Section Z FUNCHONS sa kdk aa id 8 Section Ss SIMO SONWANE rinna dei 9 Fe MEL NA a a Ga na nanna 10 Se TU pr MEMU ia ia S a a A 10 SES Menta ds 10 Program MEU lillo 11 Program A ulostart Program MERU si oi a a ik ina k n kt e n ae anne 11 SON VI GAY Sainte oken at be a Ra Lia 11 Y NP AN J ici 12 The Unit is Connected The Unit is NOT Connected een erena 12 TOO VE kk a ae n OE Om a a a a a a 13 reall TIME O CORO kwe ai titak di ta a a aime 13 Section 4 Create Edit PODA Misc ere a ep
10. currently activated analog inputs on pins 1 4 back into digital inputs This works very similar to the Analog On command because the user may only have 1 2 3 or 4 For instance if all 4 analog inputs are on but now the application only requires one analog input turn 3 digital inputs on This will result in input 1 as an analog input while 2 3 and 4 are be converted back to digital Equal to This instruction utilizes either the current analog input value along with a user defined input voltage to compare to or it utilizes a user register 1 4 and a user defined value to compare to If us ing the equal command with analog inputs the user will enter a value between O and 5 00V only two numbers after the decimal place and one before which will be compared to the current value at the specified input If the current value of the analog input is equal to the user defined voltage then the next instruction will be executed else the instruction will be skipped If using the equal command with user registers this command will read the current status of the selected user register and compare it to the user specified value and if equal the next instruction will be executed else the next instruction will be skipped Greater Than This instruction utilizes either the current analog input value along with a user defined input voltage to compare to or it utilizes a User Register 1 4 and a user defined value to compare to If using the greater than command
11. e ve ka na id 14 Aga NANG SHINS SIC OMMIM a aaa a a 15 eT RENAN Output GORMAN Skins ay dt 16 GOOF LOODS RPP tait ai e dat a a l a fe S D a n e kre e RO eee 17 Section 5 Direct Talk Mode essi a kn a n e a a a a 18 mection G TFOUPIESAOO UNTO css lella 21 A O ek lann a ti tt rt a E ai 22 SCHON Z TUONA amici 23 Appendix 1 ASCII Table TOF DIFECL NOU usa banna 26 APPenan 2 Fimware REVISION Sis 26 L010858 2 December 2012 Section 1 Introduction The PCLIO 0808 BT is a remote programmable I O that allows the user to store routines and have the PCLIO 0808 BT autostart the routines on power up It provides flexible independent control of 8 relay outputs which can be triggered on or off based on input status The PCLIO 0808 BT also gives the user the option of setting inputs to Active Low or high The easy to use Android software SignlO can be used to directly control read an I O status and store a program onto the PCLIO 0808 BT With the PCLIO 0808 BT the user no longer needs to remove unit from its resting place in the application simply scan and connect to make changes With the universal adoption of Android smart phones Anaheim Automation has made it simple for hobbyists OEMs and students to integrate wireless IO control The PCLIO 0808 BT has free fully functioning software SignlO that is available for download via the Google Play store for Android devices With this software the user has full access to the PCLIO s command set and
12. ed value If the current value of the selected user register is less than the user defined value then the next line is executed else skip the next line User Register Less User Register This sets the outputs as a group by assigning each outputs a value ON 1 or off 0 and triggers Increment outputs all at once ee REJSIE This decrements the selected user register by one Decrement e eed These commands allow the user to load any value from O to 65 535 in the corresponding register Command sets a time delay used for settling time needed after an index is finished The delay all occurs before the encoder count is read Quit This command is required as the last command in the program code L010858 19 December 2012 Section 5 Direct Talk Mode Direct mode is used to directly control motion for real time movements through serial communication The PCLIO 0808 BT controller has 8 commands which are easy to remember for direct movement of a step motor Unit Selection In order to select a unit the command followed by the address of the unit must be sent NOTE There should be no spaces between the and address select How to select a unit DO Unit O is selected Q1 Unit 1 is selected 29 Unit 29 is selected How to get a response from a unit DOS Carriage Return After the command the PCLIO 0808 BT will return a SMC60 the current revision number Note In direct talk mode each command is f
13. er mode but can act as master or slave Axis Selection Each PCLIO 0808 BT is addressed using a programmable register allowing the bluetooth master to ad dress up to 100 PCLIO 0808 BT units The Default axis is 0 To change the axis use the SignlO software to 33 or the command To verify or check the axis use the SignlO software or the command The axis designation is nonvolatile and will remain the same until changed by the user Status LED When powered and operated properly the status LED will be green When an error occurs the LED will change to red and an error code will be generated in the error code register To read and clear the error with the software click on the Verify Parameters button located in the Real Time IO Window of the SignlO software To read and clear the error while in Direct Mode use the error code command Once the error has been read and cleared the LED will return to green and the error code register will be cleared to O Refer to the table on page 24 for a complete list of the error codes L010858 4 December 2012 Electrical Specifications Power Requirements With No Connections 9VDC to 12VDC 200mA Operating Temperature O to 60 degrees C Inputs TTL CMOS Active High Logic 0 O to 0 8VDC Logic 1 3 5 to 5VDC Active Low Logic 1 0 to 0 8VDC Logic 0 3 5 to 5VDC Outputs 8 programmable 3 Amps Out Normally Open SPST Relay
14. hand Itis often helpful to have the controller connected to a computer with the software installed 910 East Orangefair Lane Anaheim Automation Inc Anaheim CA 92801 1195 Technical Support Phone 714 992 6990 Fax 714 992 0471 www anaheimautomation com Problem Cannot establish communications with the PCLIO 0808 USB Possible Solutions Make sure the PCLIO 0808 USB controller has power Is the Green LED on Check the Bluetooth connection Was the software installed successfully Go to Setup Axis and verify that the address settings are the same Click on the Setup Connect icon to communicate with the PCLIO 0808 USB controller If problems still exist contact Anaheim Automation Tech Support Fc PN aa 1 2 3 4 5 6 Problem There is no power to the PCLIO 0808 USB controller Possible Solutions 1 Is the PCLIO 0808 USB controller connected to the appropriate power supply 2 Check for any blown fuses in line with the PCLIO 0808 USB controller 3 If problems still exist contact Anaheim Automation Inc Tech Support Problem My program won t Autostart Possible Solutions 1 Verify that the Autostart Function has been enabled 2 Go to Setup Autostart Program and Click on Enable 3 If problems still exist contact Anaheim Automation Tech Support L010858 23 December 2012 Problem The PCLIO 0808 USB controller has a fault condition Possible Solutions 1 Verify your progra
15. inside an outer loop An inner loop cannot be nested inside an inner loop nor can an outer loop be rested inside an outer loop Multiple nested inner loops are allowed in one outer loop Analog On This instruction enables the analog features of the PCLIO 0808 USB module on pins 1 4 the user may enable either 1 2 3 or 4 analog inputs If analog inputs are on the user will automatically receive an On when the inputs are verified regardless of whether or not anything is connected to that pin Input 2 cannot be enabled simply as an analog input input 1 must also be enabled for input 2 to be enabled Read Analog Inputs This instruction allows the user to retrieve the current voltage level at the specified input Note If the user wants to read the voltage level of an input that input must be activated to be of analog type to avoid getting an error The voltage value returned will be from O to 5 volts and the resolu tion is up to 400mV L010858 8 December 2012 Interrupts This instruction will run a stored interrupt routine when triggered by the specified interrupt Only pins 5 7 can operate as interrupt pins and are activated according to the Active High Low state of the input register When the input is activated the program will stop what it is doing and immediately jump to the specified label If the user wishes to use this interrupt as a regular digital input the interrupt must be turned off Digital Inputs This instruction turns the
16. is to directly talk to the PCLIO 0808 BT by using Direct Talk Mode This can be done with any bluetooth master where the bluetooth master gives the PCLIO 0808 BT serial commands to off load its processor For example a bluetooth master can use the direct talk commands to toggle outputs verify inputs change the active state of inputs and change or verify axis The second way to give commands to the PCLIO 0808 BT is to use the software program SignlO which works with any Android device 2 2 or above to either manually control or upload download programs to the PCLIO 0808 BT SignlO is integrated with branching looping conditional statements time delays and text strings to handle any and all of the user s application requirements With operating ranges of up to 300 feet one could use SignlO to monitor the status of their system with their phone from afar Bluetooth Transmission Bluetooth is a proprietary open wireless communication standard utilized to exchange data from fixed and mobile devices creating personal area networks Bluetooth communication is secure in that it employs several layers of data encryption and user authentication measures The PCLIO 0808 BT utilizes Bluetooth version 2 1 and is backwards compatible with Bluetooth version 2 0 1 2 and 1 1 Currently the PCLIO 0808 BT comes in Class 1 and Class 2 models with operating ranges of 60 feet and 300 feet respectively The PCLIO 0808 BT at this time does not support multipoint mast
17. ive Low then tieing inputs to 5V will give an on state and grounding inputs will give an off state Range 0 1 Read inputs Format 1 IR Description This command returns the binary value of the inputs to the Bluetooth master This command works with the Active Low high register of the inputs so they will return a high when they are open if in Active High or if in Active Low and grounded For example if inputs are Active Low and grounded the command will return a 255 If all inputs are Active High and grounded the command will return a 0 Format 2 input Description This command returns the value of the selected input to the bluetooth master lf the Active High Low register is set to High and the input is high it will return a 1 else if the input is low it will return a 0 If the the Active High Low register is set to Low and the input is grounded it will return a 1 else if the input is high it will re turn a O Range 0 8 Error codes register Format Description This command requests the PCLIO 0808 USB controller to get the current error code and print it to the screen For a description of the error codes see page 24s Version number register Format Description This command requests the PCLIO 0808 USB controller to return it s internal firmware version number L010858 21 December 2012 O Set outputs Format 1 OR value Description This command sets the output register according
18. l to an input will correspond to that input being ON If the toggle button reads Active High a 5 VDC signal will trigger the input to be ON This button will verify the On Off Analog Digital and Active High Low state of your inputs as well Verify Parameters as clear the current error Inputs Context Menu Note To access the Activate Analog Input inputs context menu you must press down on Read Input the Input for an extended amount of time Activate Digital Input cia 11 08am 3 E This changes the functionality of the first four inputs from strictly digital ON OFF to ana Activate Analog Input log 0 5V You can either have input 1 input 1 2 input 1 3 or input 1 4 be analog you are unable to just have input 2 be analog without 1 being analog Activate Digital Input This changes the functionality of the first four input from analog back to digital If the input is enabled as analog the current voltage at that input will be displayed If the input is enabled as digital it will display whether the input is ON or OFF Read Input L010858 14 December 2012 Outputs Tab OUTPUTS Verify Outputs ca 10 19am F This will return the state of the Output ON OFF Output Context Menu Verify Outputs Note Output 1 To access the outputs context menu you must Turn Off press down on the Input for an extended amount of time Turn On Current Status ca 11 13am 3 Tum On
19. ler is in a wrong mode Some commands are good only in programming mode while others are good only in direct mode Check the direct mode section to see which commands are good in direct mode There were no parameters sent to the controller An instruction was sent to the controller without the necessary parameters after the command The specified address is out of range This is caused by overflowing the program memory by having a program that is to large The command pulled from memory is invalid The command that was stored into the eeprom was non executable by the program This is an internal error 24 December 2012 Appendix 1 ASCII Table for Direct Mode Hex Hex Hex woe ASCII Symbol wane ASCII Symbol Eme poe Fw a ASCII Symbol H 48 Carriage 7E Return i HH A L010858 25 December 2012 Copyright Copyright 2004 by Anaheim Automation Inc All rights reserved No part of this publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without the prior written permission of Anaheim Automation Inc 910 East Orangefair Lane CA 92801 The only exception to this would be use of the program examples in this manual Disclaimer Though every effort has been made to supply complete and accurate information in this manual the contents are subject to change with
20. m for improper syntax that may cause an error code 2 Physically press the reset button on the PCLIO 0808 USB to clear an error 3 To clear an error click on the verify parameters button using the SignlO software or use the direct mode clear error command 4 The direct mode command E can clear an error by simply prompting the error code register to return the value back to the bluetooth master Note Read the error returned to the screen to better understand what can be causing the fault condition The error is returned in binary coded decimal format If two errors were received their binary values would be added together Error Codes Receive Overflow Error Command Error Range Overflow Error Range Error Transmitt Error Mode Error Zero Parameters Error Memory Range Error Memory Com mand Error L010858 Description The serial communications had a receiving error This is an internal error caused by the computer A bad command was sent to the controller Please check to see that the command being sent is valid The wait command has an overflow error This is caused by the W command trying to wait an amount of time that is out of range There was an invalid number of commands and characters sent to the controller Check to see if the parameters are invalid for the command that was sent Too many parameters sent back to the PC This is an internal error caused by the ee prom Control
21. nputs can programmatically be set to Active Low or High as a group The inputs are TTL and may be used for inter axis coordination in stored program mode for operator intervention for sensing a machine condition such as out of stock to initiate a machine cycle or wait for temperature to be reached etc When Active High a grounded input will read a 0 and a high input will read as a 1 vice versa when Active Low There are 4 analog inputs that can return a 10 bit value which can be used to monitor oven temperatures fluid pressure and fluid flow rate Along with these 4 Analog inputs the PLCIO 08080 USB is equipped with three interrupt inputs that can trigger various routines stored in memory Pull Up Down Inputs This instruction sets the active state of all the inputs For instance if the inputs are set to Active High a 5 volt signal will illicit an On status for that input If a O volt signal is applied the the input will display an Off status If the inputs are set to Active Low a 5 volt signal will display an Off status for that input If a O volt signal is applied the input will show an On status Outputs Eight outputs are provided per axis Outputs are of relay type which are perfect fits for appli cations such as coolant valves air cylinders or with the correct interfacing any electronically controlled device The outputs can drive all types of common peripheral power loads including lamps solenoids LEDs printer heads
22. ollowed by a carriage return The unit communicates in half duplex mode therefore proper setup of Hyper Terminal is necessary to view characters if characters are to be echoed back to the screen Instructions All instructions require that no spaces be sent between the command and the parameter followed by a carriage return DO not 0 Examples Correct DO carriage return Incorrect O carriage return Command Summary Read inputs H Inputs Active Low High O Set outputs D Digital Inputs V Verify l Error codes register Version number Verify axis number Set address of PCLIO 0808 USB L010858 20 December 2012 D Set Digital Inputs Format 1 D input This command turns the currently activated analog inputs on pins 1 4 back into ESPEN digital inputs For instance if inputs 1 2 amp 3 were currently activated as analog inputs a D2 command will turn input 3 back into a digital input If 4 inputs were activated as analog inputs a D3 command will convert inputs 2 3 amp 4 back into digital inputs Range 1 4 H Set Inputs as Active High or Active Low Format 1 H1 or HO Description This command will set the state of your inputs to either Active Low H1 or Active High HO If the user decides to set the inputs as Active Low then grounding the inputs will show an on state while tieing the inputs to 5V will show an off state If inputs are set as Act
23. out notice or obligation to inform the buyer In no event will Anaheim Automation Inc be liable for direct indirect special incidental or consequential damages arising out of the use or inability to use the product or documentation Limited Warranty All Anaheim Automation Inc products are warranted against defects in workmanship materials and construction when used under Normal Operating Conditions and when used in accordance with specifications This warranty shall be in effect for a period of twelve months from the date of purchase or eighteen months from the date of manufacture whichever comes first Warranty provisions may be voided if the products are subjected to physical damage or abuse Anaheim Automation Inc will repair or replace at its option any of its products which have been found to be defective and are within the warranty period provided that the item is shipped freight prepaid with RMA return material authorization to Anaheim Automation s plant in Anaheim California Trademarks Control Link and Driver Pack are registered trademarks of Anaheim Automation Inc IBM PC is a registered trademark of International Business Machines Inc ANAHEIM AUTOMATION INC L010858 26 December 2012
24. peripherals Description The PCLIO 0808 BT also has a high level programming command set that includes branching looping conditional statements time delays text strings and I O which the user can use in the programming mode to fully control all machine functionality The I O may be used for monitoring and controlling machine operation and or interaxis coordination The PCLIO 0808 BT has a built in programmable reset circuit Reset is automatic on power up or by pressing the external reset button The software allows the user to write and change programs that are to be stored in the PCLIO 0808 BT for autostart use as well as upload the program that is stored in the PCLIO 0808 BT itself for editing and viewing The software also allows the user to store the programs onto their phone or tablet and easily retrieve them when needed Application Profile The PCLIO 0808 BT is great for hobbyists who are trying to network their home The PCLIOBT s relay outputs are perfect for controlling home appliances as it eliminates the need to flip a switch Instead the user can tum it on with their phone or tablet For example a humidity sensor can be hooked up to the PCLIOBT so a sprinkler system can be controlled via the user s phone Anaheim Automation has made everything plug and play greatly simplifying home automation L010858 3 December 2012 Methods of Communication There are two methods for sending commands to the PCLIO 0808 BT one method
25. to the binary value entered Output 1 is the LSB and output 8 is the MSB Range O 255 Format 2 O output 0 or 1 Description This command sets the selected output either on or off A 1 will turn the output on OVDC and a O will turn the output off open Range 0 8 V Verify Verify Outputs Format 1 VO Description This command is used to verify the state of the outputs by displaying a value between O and 255 Verify Analog Inputs Format 2 VA Description This command is used to verify how many inputs are activated as analog and will return a value from 1 4 Verify Inputs Active Low High Format 3 VH Description This command is used to verify whether inputs are Active Low or high A 1 is displayed if inputs are Active Low and a O if inputs are Active High Verify User Register Value Format 4 VT 1 4 Description This command is used to verify the current value of the specified user register Set Address Register Format value No address is needed before this function value will set the address Description This command sets the address for communication inside the PCLIO 0808 USB controller Range 0 99 L010858 22 December 2012 Section 6 Troubleshooting Technical Support Common troubleshooting issues are covered in this section if you require additional assistance beyond the scope of this manual please contact the factory direct If possible have this manual in
26. with analog inputs the user will enter a value between 0 and 5 00V only two numbers after the decimal place and one before which will be compared to the current value at the specified input If the current value of the analog input is greater than the user defined voltage then the next instruction will be executed else the instruction will be skipped If using the greater than command with user registers this command will read the current status of the selected user register and compare it to the user specified value and if greater than the next instruction will be executed else the next instruction will be skipped Less Than This instruction utilizes either the current analog input value along with a user defined input voltage to compare to or it utilizes a User Register 1 4 and a user defined value to compare to If using the Less Than command with analog inputs the user will enter a value between O and 5 00V only two numbers after decimal place and one before that will be compared to the current value at the specified input If the current value of the analog input is less than the user defined voltage then the next instruc tion will be executed else the instruction will be skipped If using the Less Than command with user registers this command will read the current status of the selected user register and compare it to the user specified value and if less than the next instruction will be executed else the next instruction will be skipped
27. y selecting Setup Axis from the menu bar 4 Establish communications with the PCLIO 0808 BT by clicking on the Connect icon and selecting the appropriate bluetooth IO L010858 10 December 2012 Connect Menu Active Low Verify Parameters Input 1 Input 2 Note This menu is only accessible when Input 4 you are not con nected to a unit Input 3 Input 5 This menu will be Input 6 DT populated with Ta different options Input 7 a once connected Input 8 Connect Make discoverable Disconnect ci 10 20 m F Connect This will initiate the connect sequence Make Discoverable This will allow other bluetooth devices to see you Disconnect This will disconnect you from the bluetooth device you are currently connected to Select Device select a device to connect Paired Devices L B C2 90 06 66 45 1C 2F Scan for devices ci 3 34 pu Y After selecting connect the user will be prompted to select a device or pair a new device L010858 11 December 2012 Connected Menu Note E E This menu is only N accessible when you are not connect FI to a unit and in the Inputs or Outputs Tab This menu will be populated with different options if disconnected or in the programs tab Bluetooth Preferences Bluetooth Preferences Select Axis Define Axis Disconnect Bluetooth Preferences Bluetooth Preferences hen setting 10 unit Name you have two options set a Name