Home

Braintree Scientific Catalog

image

Contents

1. 27 Quick Connect Infusion System Complete Kits Years of hands on research experience has translated into technology that makes sense to the end user SAI has replaced the catheter swivel and extension line friction compression fittings with secure easy to attach luer locks This small change is capable of reducing scheduling loads by 75 or more for infusion related procedures such as blood draws infusion set up intermittent infusions body weights cage changing and general catheter maintenance The system includes the Quick Connect harness tether and swivel All the components work together to save time reduce costs and improve the integrity of user s infusion and access system All systems and components are ETO exposed MODEL DESCRIPTION QCK 23 Quick Connect Kit including 23G harness 12 tether and dual luer swivel QCK 21 Quick Connect Kit including 21G harness 12 tether and dual luer swivel QCK 23J Quick Connect Kit including 23G jacket adaptor jacket 12 tether and dual luer swivel QCK 21J Quick Connect Kit including 21G jacket adaptor jacket 12 tether and Dual Luer Swivel International and US patent 7 665 424 A Quick Connect Harness and Jackets The Quick Connect Harness provides the luer connection between catheter and any male luer fitting It can be used separately for procedures such as bolus dosing intermittent infusion catheter maintenance and timed blood draws whe
2. a Physiology Equipment MouseOx Small Animal Pulse Oximeter gt Arterial oxygen saturation gt Pulse rate gt Pulse distention gt Breath rate Introducing the world s first and only pulse oximeter for mice and rats Multiple cardiopulmonary measurements from one non invasive sensor clip MODEL SLS 000765 SLS 000767 STARR Link Analog Output Module Se A i a STAR Ap d ess Output beat by beat MouseOx data in analog form to another recording system starr Link analog output module provides real time analog voltage outputs of MouseOx data STARR Link DESCRIPTION MouseOx with Analog Pulse Output select two sensors MouseOx select two sensors G transmits all MouseOx data at 15 Hz using a 0 5 VDC scale Connects easily to computer with a USB cable It has no external power supply and is automatically recognized by MouseOx software No additional software is needed MODEL DESCRIPTION SLS 000003 STARR Link MouseOx Non invasive Sensors gt Easily applied by one person gt Monitor conscious unrestrained or anesthetized animals gt Monitor hypothermic and hypovolemic animals Five sensors per pack MODEL SLS 000749 SLS 000750 SLS 000751 SLS 000752 SLS 000753 SLS 000754 SLS 000755 SLS 000756 SLS 000757 SLS 000758 SLS 000759 SLS 000760 SLS 000761 SLS 000762 DESCRIPTION XS CollarClio Sensor conscious mice and young rats S CollarClip
3. gt Two flexible LED lights provides direct illumination no shadows and no heat gt Limb restraints gt Size 9 x13 5 Micro Tattooing Platform gt One Flexible LED light provides direct illumination with no heat gt Cup holders 1 5ml gt Size 6 x 9 MODEL DESCRIPTION ASS7 Surgery Platform NTSO1 Micro Tattooing Platform Dissection Tray Add a dissection tray with a wax base pinning surface for detailed dissections MODEL DESCRIPTION DIW1 Dissection Tray 9 5 x 7 x 1 DTW5 Dissection Tray five trays per pack Tail Vein Injection Platform The quickest and easiest restraint for tail vein injections Simply pull mouse tail through the slot and make injection Non g rip su rface gt Wide opening for easy access gt Open slot for easy cleaning feces and urine easily washed away MODEL IL 300 DESCRIPTION Tail Vein Injection Platform Surgical Tables and Boards Tail Snipping Platform For isolating DNA from transgenic animals for genotyping a simply pull mouse tail through the slot measure and collect tip in the vial gt Micro Tube Holder Collect tail tio directly in the prelabeled tube preventing DNA cross contamination gt Measuring Ruler mm Accurately measure tail length for cutting Enhances IACUC compliance gt Cleaning Slot Feces and urine are easily washed out with stream of water minimizes cross contamination MODEL DESCRIPTION IL 200 Tail Snipping
4. Disposable Cages for Rodent Transportation The Innovive disposable transportation cage allows transportation of mice in the same cage that they are housed with a simple change of the lid reducing animals disturbance with a simple change of the lid Rodent Transportation Challenges gt Maintaining a low stress and healthy environment for animals during long and short haul transportation gt Discrete and secure rodent caging gt Cost effective transportation solution Advantages of Innovive Transportation gt Healthy air for the trip of any length large top filters provide excellent intracage airflow which allows 5 mice to be housed in the Innocage up to 7 days gt Secure transport cage for mice the cage s snap top secures animals during the trip gt No water or food tray needed simply add a gel pouch and animals are ready to go gt Disposable caging is a cost effective solution remove the need to track return and or replace expensive traditional rodent cages Innocage Transport Mouse Transport Lid Whether moving animals a short or long distance the Innocage Transport is a great solution Simply replace an IVC lid with a transport lid to prepare the animals for relocation Maintain a complete stock of transport cages for distributing animals from a breeding operation to primary housing areas Accessories 5 rh 7 TA 1 Mouse water Botte Mouse Feeder Card Holder MODEL DESCRIPTION Q
5. MODEL DESCRIPTION CLP 9931 Pocket Pro Pet Trimmer Safe T Light Trimmer gt Industry s first illuminating animal trimmer gt Ultra bright white no heat LEDs gt Dual Beam LEDs for safer more precise trimming gt Cord cordless trimmer can be used with or without cord attached gt Ni MH battery for superior performance and less memory effect gt Carries enough charge for all day average use recharges to full power overnight gt Dual voltage charger included for worldwide use MODEL DESCRIPTION CLP 24090 Safe T Light Trimmer with 40 S S Blade Replacement Blades CLP 22880B 40 S S Replacement Blade CLP 22945B Leaves Hair 0 1mm T Style Blade Professional Clipper Professional clipper runs so cool fans and air vents that can become clogged with hair are not needed gt Maintenance free no oiling or greasing of internal parts is needed gt Includes size 40 detachable blade set gt All Model AG blade sets are made of high carbon Steel specially hardened for long cutting life gt Locking switch button will not accidentally shut off gt 2 00 RPM MODEL CLP 22345 Replacement Blades CLP 64084B 40 Surgical S S Detachable Blade CLP 64071B 10 Medium Cut Detachable Blade CLP 64160B Ultrafine Blade Surgical S S Detachable Blade With Cord DESCRIPTION Professional Clipper Shop online at www braintreesci com IN ar 7231BRASCI_NOPRICE 12 13 12 11 41 AM Page 59
6. gt Size 13 5 Lx 9 W MODEL DESCRIPTION ASS7T Thermo Control Surgery Platform with Space Gels SPGL S Space Gel Pad 4 x6 SPGL L Space Gel Pad 5 5 x10 SPDR space Drape 12 x 6 2 pk ASS7D Thermo Control Surgery Platform with Deltaphase Pads DPIP Deltaphase Isothermal Pad 6 x 7 5 See microscope section for digital microscope attachments SpaceDrapes SpaceDrapes provide heat retention capabilities while doubling as surgical drapes They decrease recovery time and improve recovery prospect for animals that are under anesthesia by reducing radiant heat loss They can be fenestrated and used as standard drapes Available pre packaged and pre sterilized or in rolls that can be sterilized by the user MODEL DESCRIPTION SPDR Space Drape 12 x 16 Flat 2 pk SD MPS 4 x 5 Mouse Pouches 1 sterilized package of 5 pouches SD RPS 9 x 12 Rat Pouches 1 sterilized package of 5 pouches SD RNS 12 Roll non sterile 100 26 BRAINTREE SCIENTIFIC 781 348 0768 a Thermo Controlled Recovery Pad Animal recovery made simple and easy Shoe box cage not included Place animal on pad for recovery Recovery pad will provide over 2 hours of Thermo Regulation gt Convenient size 13 5 Lx 7 5 W gt 6 space gels for continuous heat gt 4 space blankets to retain heat gt Thermo reflector and turbo heat sink to maximize heat transfer gt Non skid feet for added stability gt Fits into a standard 1
7. 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 33 a Quiet Tattoo Machine version also available Reduces noise level which leads to a calmer animal 54 lighter better balance less hand fatigue MODEL DESCRIPTION NEO 9 Neonate Rodent Tattoo System Includes Lab Animal Tattoo Identification Vol 1 Neonate Mice amp Rats and DVD Instruction Video NEO 9Q Quiet version of the NEO 9 ATS 3 General Rodent Tattoo System Includes Lab Animal Tattoo Identification Vol 2 Adult Mice amp Rats and DVD Instruction Video ATS 3Q Quiet version of the ATS 3 ATS 3L Large Lab Animal Tattoo System with instruction book ATS 3LQ Quiet version of the ATS 3L NEO AP Neonate Accessory Package NTS 01 Micro Tattooing Platform Large Lab Animal Upgrade Package LLA AP Adds custom accessories and detailed instructions to easily tattoo identify large lab animals Battery Operation Upgrade Package BPO AP Adds remote operation capabilities to the ATS 3 Eliminates need for electrical outlet Allows extended operation in any location Ideal for field work animal identification Ear Punch a MODEL DESCRIPTION EP 901 1mm Punch scissor style EP 902 2mm Punch scissor style EP 900 Ear Punch 2mm thumb style EP M900 Miltex 2mm thumb style Small Animal Ear Tag stainless steel applicator is designed to seal tags with minimal pressure while providing a secure seal Applicator can be used with or without the s
8. Extremely slim design of the Microvette CB 300 s capillary tube ensures optimum serum plasma recovery following centrifugation MODEL DESCRIPTION UNITS MICROVETTE CB300 0 3ML MCB 16440 BX Serum Clotting activator 100 pk MCB 16440 CS Serum Clotting activator 1000 cs MCB 16443 BX Lithium Heparin 00008 100 pk MCB 16443 CS _Lithium Heparin 000 1000 cs MCB 16444 BX Hematology Potassium EDTA 100 pk MCB 16444 CS Hematology Potassium EDTA 1000 cs IN ar 7231BRASCI_NOPRICE Multivette 600 Capillary and one system 12 13 12 11 38 AM Page 35 venous blood collection in The unique Multivette 600 is the only product that can collect both venous and capillary blood For venous blood collection a Luer needle is connected to the capillary tube of the Multivette which automatically fills by normal venous pressure Capillary blood is performed using the end to end principle The special pre assembled capillary tube is designed to hold 600uL of blood MODEL DESCRIPTION UNITS MULTIVETTE 600uL MLT 151670 BX Serum Clotting Activator 0 100 pk MLT 151670 CS Serum Clotting Activator 1000 cs MLT 151674 BX Serum Gel Clotting Activator 100 pk MLT 151674 CS Serum Gel Clotting Activator 1000 cs MLT 151673 BX Plasma Lithium Heparin 4 100 pk MLT
9. NB 22 22 gauge 1 NB 21 21 gauge NB 20 20 gauge 1 Perfusion manifolds can be used in any application where from 2 to 8 perfusion lines are required to be connected to a chamber or other device Manifold inputs converge to the common output with minimum dead space Sh arp Tip Catheter Needles Designed for use with polyethylene PE tubing manifolds can be used with ao et a any other tubing of similar dimensions When connected to a chamber via a short length of tubing very rapid solution changes are possible Miniature manifolds are useful for applications involving small volumes or Ultra sharp tri beveled anti coring stainless steel needle Translucent color coded luer lock hub Supplied sterile Slow flow rates small diameter niaan MODEL DIMENSIONS tubing is used with these models VOL 5 MICRO L NS 30 30 gauge 0 5 PE 50 tubing for the input ports 7 NS 27 27 gauge 0 5 and PE 10 or PE 50 tubing for the NS 25 25 gauge 1 MM or ML seri 149 NS 23 23 gauge 1 or ML series output ports NS 22 22 gauge 1 respectively an sae Specifications i Material Delrin MM 6 MANIFOLD NS 18 18 gauge s VOL 5 MICRO L Large Diameter 8 0mm r Stainless Steel Port Plugs Sp rk E j l 0 y eng P mm i 180 Stainless steel port plug 0 5 length Input Tubing PE 50 AG T D MODEL DIMENSIONS Output Tubing ML Series PE 50 PP 30 0 012 plug MM Series PE 10 H o PP 28 0 014 plug PP 27 0 016 plug MODEL D
10. Open lid and rotor quickly decelerates for removal of samples At just 5 5 wide and less than 4 5 tall MyFuge 12 truly is a personal centrifuge with unmatched capacity and flexibiilty Specifications Speed 5 500 rom 2 000 xg Capacity 12 x 1 5 2ml tubes 32 x 0 2ml PCR tubes 4 x PCR strips 8 x 0 2ml Dimensions 5 5 x 7 9 x 4 4 14 cm x 20cm x 11 2cm MODEL DESCRIPTION C1012 MyFUGE Mini Centrifuge with COMBI Rotor for microtubes and PCR strips tubes C1008 A5 6 Adapters 0 5ml pack of 6 C1008 A2 6 Adapters 0 2ml pack of 6 Compact Lab Centrifuge spectrafuge 6C is designed for quick production of PPP platelet poor plasma and PRP platelet rich plasma as well as other applications in clinical and research laboratory Removable rotor of the Spectrafuge 6C accepts 6 x 15ml tubes and with the adapters will accommodate all common blood draw tubes Variable speed allows for a variety of applications to be performed A timer controls operation from 30 seconds to 30 minutes Time can also be set to continuous by selecting on position or momentary by pressing and holding start knob Control panel features easy to turn knobs and large digital displays for time and speed During operation the lid is locked Once the rotor has come to a Stop both the time and speed displays flash 00 to signify that run has been completed Lid can now be opened by pressing the lid knob A small footprint allows the Spectraf
11. Supplied non sterile MODEL SIZE MRE 025 0 025 OD x 0 012 ID 0 64 OD x 0 30 ID mm MRE 033 0 033 OD x 0 014 ID 0 84 OD x 0 36 ID mm MRE 040 0 040 OD x 0 025 ID 1 02 OD x 0 64 ID mm MRE 050 0 050 OD x 0 040 ID 1 27 OD x 1 02 ID mm MRE 065 0 065 OD x 0 030 ID 1 65 OD x 0 76 ID mm MRE 080 0 080 OD x 0 040 ID 2 03 OD x 1 02 ID mm MRE 095 0 095 OD x 0 066 ID 2 41 OD x 1 68 ID mm MRE 160 0 160 OD x 0 091 ID 4 06 OD x 2 31 ID mm p MRE 037 0 037 OD x 0 023 ID 0 94 OD x 0 58 ID mm MRE 040 S 20 0 040 OD x 0 020 ID 1 02 OD x 0 50 ID mm MRE 080 S 38 0 080 OD x 0 038 ID 2 03 x 0 96 ID mm t MRE COMBO Combination of 36 feet in your choice of sizes MRE 010 0 010 OD x 0 005 ID 0 25 OD x 0 12 ID mm Kit includes 12 individually packaged 3ft lengths tMinimum 36 when ordering continuous lengths More length options available online at braintreesci com Teflon Coated Guide Wire MODEL SIZE ST003 14 0 003 Teflon Coated Guide Wire 14 L non sterile ST003 7 0 003 Teflon Coated Guide Wire 7 L non sterile A Guide to Manufacture Surgical Implantation Maintenance and Use of Micro Renathane Vascular Catheters in Laboratory Animals by Alfred Sherer D V M and Lewis Kinter Ph D This comprehensive manual includes how to manufacture catheters from Micro Renathane tubing different implantation techniques catheter use and maintenance MODEL MRE MANUAL Visit us online at www brain
12. gt 0 1 2 5mm spot size gt Dual laser gt Maximum temperature and hold features gt Easily switches from C to F gt Clock and chronograph gt Adjustable emissivity Measure temperature precisely to 0 1 2 5mm with the CF IR Close Focus Infrared Thermometer Great for electronic components laboratory measurements and research Measures tiny areas with precision CF IR multi line display includes a real time clock and measurement of ambient temperature for convenience Other features include Min Max Hold adjustable emissivity and built in stop watch Measure temperatures from 67 F to 428 F at 0 7 18mm distance MODEL DESCRIPTION CF IR Close Focus Infrared Thermometer Visit us online at www braintreesci com 31 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 32 a Animal ID Systems AIMS Neonate and General Rodent The AIMS ATS 3 General Rodent Tattoo System Tattoo Systems Simple quick and easy permanent animal identification supplies and accessories to tattoo 3000 weanling rodents and larger The detailed training guide and instruction DVD provide step by step guidance with detailed illustrations Use numbers letters lines dots and or colors to permanently ID any color strain mouse or rat Convenient comprehensive kits for the humane tattoo identification of neonate or adult mice and rats Each kit is provided with a comprehensive training guide and instruction DVD and a
13. Cage Stands and Racks Cage Stands gt Stainless steel nylon supports gt Holds one rodent metabolic cage Vertical Metabolic Cage Rack gt Holds up to 12 Techniplast metabolic cages for small rats and mice 3 x 4 configuration gt Can also be adjusted to hold eight cages for large rodents Rack is mounted on swivel casters two lock for safety Horizontal Metabolic Cage Rack gt Holds up to 12 Techniplast metabolic cages for small rats and mice gt Holds two horizontal rows of six cages each gt Convenient working height 2 x 6 configuration gt Rack is mounted on swivel casters two lock for safety MODEL DIMENSION MTB 0400 Cage Stands Dim Lx Wx H 12 5 x 12 5 x 13 375 31cm x 31m x 34cm MTB 0500 Vertical Metabolic Cage Rack Dim L x W x H 49 5 x 19 5 x 73 5 125cm x 50cm x 187cm MTB 0600 Horizontal Metabolic Cage Rack Dim Lx W x H 70 0625 x 24 812 x 50 812 178cm x 63m x 129cm IN ar 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 77 Lab Standard Stereotaxic Instrument Single and dual manipulator models gt Read from the open end of the U gt Large easy to read numerals on scale gt Precise alignment to 0 1mm resolution gt Triple start lead screws for fastest positioning possible gt Absolute lock at 90 Universal joint allows scientist to probe in either anterior posterior or lateral medial planes Manipulator arm may be i swiveled out of the way for
14. Catheter port is designed to exit between the scapulae and to be secured with a single Autoclip 9mm stainless steel wound clip Polyethylene PE tubing catheter body The rigidity of PE tubing minimizes the incidence of catheter lumen constriction and relaxation an eye dropper effect which allows blood to enter the intravascular tip All catheter anchor points allow for suturing around the PE tubing minimizing the likelihood of suture induced catheter lumen constriction RenaSil intravascular tip Renasil as the intravascular tip for reducing intravascular thrombus formation Reduced diameter intravascular tip Reducing the inner diameter of the intravascular tip relative to the inner diameter of the port allows for efficient expulsion of blood from the intravascular tip The last step following catheter implantation or use should be to advance the stainless steel plug into the port for a few millimeters This is sufficient to expel trace amounts of blood from the intravascular tip with a minimum amount of catheter lock solution entering the bloodstream Patency especially for blood sampling is highly dependent on the location of the intravascular tip Thoracic Catheter suitable for blood sampling and or drug infusion in either the jugular vein or carotid artery of the rat or mouse Shown with disk A subcutaneous retaining disk consisting of 0 5 diameter disk of surgical mesh attached at the base of the cat
15. MicroVent 1 Ventilator capable of providing ventilatory support for intubated animals Dual mode ventilator will operate to deliver standard intermittent positive pressure ventilation IPPV or it will operate to deliver high frequency oscillatory ventilation HFOV The entire breathing system has a volume of less than 1cc There are just four parameters to control Oxygen Flow Frequency BPM Amplitude VT and Mean Airway Pressure MAP MODEL DESCRIPTION MV A3760 MicroVent 1 74 BRAINTREE SCIENTIFIC 781 348 0768 e gt es E poe ry v2 A bi 1 f is a Model 2000 Small Animal Ventilator small animal economical ventilator is designed to be used with animals ranging in weight from 1 to 200 kg gt Time cycled Insures consistent repetitious dependable breathing at respirator rates adjustable from 6 40 breaths per minute maintaining the patient at a more stable depth of anesthesia gt Volume constant Insures that each delivered breath will have essentially the volume independent of changes in patient compliance and airway resistance Deliverable tidal volume TV range is from 20cc to 3 000cc gt Pressure limited Provides for patient safety by limiting the maximum working pressure MWPL to a user adjustable pressure range of 10 60cm H20 gt Interchangeable bellows Keyed filling for safer and pollution reduced filling and draining MODEL DESCRIPTION VEN2000 A 300 1600ml Bellows VEN2000
16. Mouse Kit 10 grams MI Kit Each kit contains all the necessary equipment to perform small rodent intubations fast easy and relatively painlessly gt Fiber optic illuminator FO Light gt Appropriate size fiber optic stylet FOS xxx gt 5 pack of the appropriate size endotracheal tubes ETT xx 05 gt 3 pack of lung inflation bulbs LIB 03 20 BRAINTREE SCIENTIFIC 781 348 0768 a Though the BioLITE System was initially created for intubation it remains a highly efficient small core fiber optic illumination system and can essentially be used in any application that requires intense illumination of a small space in a tortuous location For those interested in alternate applications or have no need for the intubation accessories we offer a Stylets Kit FO Kit that includes a mouse fiber optic stylet FOS 400 400um core diameter a small rat fiber optic stylet FOS 600 a big rat fiber optic stylet FOS 800 and a fiber optic illuminator FO Light MODEL DESCRIPTION MI kit Mouse Kit for Mice 10 grams includes 1 FOS 400 1 FO Light 1 LIB 03 and 1 ETT 20 05 SR Kit Small Rat Kit for Rats 100 200 grams includes 1 FOS 600 1 FO Light 1 LIB 03 and 1 ETT 16 05 LR Kit Large Rat Kit for Rats 200 grams includes 1 FOS 800 1 FO Light 1 LIB 03 and 1 ETT 16 05 FO Kit Stylets Kit includes 1 FOS 400 1 FOS 600 1 FOS 800 and 1 FO Light CO Kit Complete Kit includes 1 FO Kit 1 LIB 03 1 ETT 16 05 and
17. Rad Disk and Rad Disk Mini animals can be transported to the radiation source even if traveling through a contaminated environment Sterile Transportation After irradiation at location outside of the animal facility Rad Disk and Rad Disk Mini containing animals are prepared for re entry into animal facility by placing a strip of plastic tape over each aligned row of airholes completely sealing lid and allowing for liquid Sterilization of exterior of cage prior to facility re entry check with facility management for SOP which may vary from institution to institution Once decontaminated taped cage can be taken to the sterile or clean change Station and animals may then be transferred back to their original or new S l of animals for acute studies cages Tape can be removed from lid after transporting cage to wash area Z4 The rat cages have tail slots for for reprocessing Any contaminants are trapped on outside of filter between i i k i r ip peg La intravenous dosing airholes and lid so leaving tape in place prevents exposure to facility MODEL DESCRIPTION environment MPC 1 Mouse Pie Cage Rad Disk and Rad Disk Mini are easy to clean store and sterilize for use Unit dimensions 21 5cm dia 7 5cm height MODEL DESCRIPTION Individual chambers feature 5cm base and and 9cm length ey MPC 2 Mouse Pie Cage with filter top and filter IRD P M Mouse irradiator Cage with Divider polycarbonate l a aes 8 875 dia X 3 875 H MPC
18. available to customize the placement of the animal on the stand in order to meet the user s needs Two sets of posts are provided with each stand Each post has three positions for the height adjustment to optimally accommodate user and animal stand is constructed from a single piece of polycarbonate plastic with a seamless design The top of the stand provides a hand rest for stabilization during intubation that is designed to support significant weight Compact seamless design and its construction make this stand easy to clean Will not crack with the use of harsh cleaning agents as with similar stands constructed from acrylic MODEL DESCRIPTION RIS 100 For Mice RIS 200 For Rats Visit us online at www braintreesci com 19 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 36 AM Page 20 Intubation BioLITE Intubation Illumination System FO Light D he NS yf The BioLITE system provides better anatomical visualization and combines several tools into one reducing the intubation time making the intubation process fast and easy The BioLITE System consists of a family of products fiber optic illuminator FO Light fiber optic stylets FOS endotracheal tubes ETT and lung inflation bulbs LIB packaged in a variety of kits to meet the individual needs for a variety of research interests Unlike other flashlight based fiber optic illuminators the FO Light houses an optical system that provides high
19. oon E QTY CASE MODEL DESCRIPTION Approximate inside dimensions 26mm L x 26mm W x 90mm D Holds approximately 60ml 900570 Coplin Jar with PP Screw Cap ee eee 6 900522 Replacement Cap 58 400 00 0 0c eee 6 900470 Coplin Jar with Glass Cover 0 0 0 0 eee een 6 Visit us online at www braintreesci com 39 7231BRASCI_NOPRICE 12 13 12 11 39 AM Page 40 Stainin Staining Jar 8 10 Slide Unit Wide top for convenience in transferring slides suitable for staining slides that are inscribed on one end Holds eight single 3 x 1 75mm x 25mm slides vertically or 16 slides back to back MODEL DESCRIPTION QTY CASE Approximate inside dimensions 42mm L x 26mm W x 85mm D 900620 Staining Jar with Cover oo cee 6 Staining Dish 10 20 Slide Unit Manufactured from soda lime glass 20 slide unit is the standard for manual staining procedures Removable glass slide rack has an open bottom to facilitate rapid immersion and drainage reducing carryover Rack holds 10 single Slides 19 slides arranged alternately straight across and diagonally or 20 slides back to back of standard size 3 x 1 75mm x 25mm 3 x 1 5 75mm x 38mm and 3 x 2 7omm x 51mm sizes MODEL DESCRIPTION QTY CASE Approximate inside dimensions 95mm L x 76mm W x 64mm D 900200 Complete Dish Cover Rack Handle 6 900201 DISI ox rac aeps is ones ave rad as dine odd EN ATAT i 3 900202 COVEI out ned Gh dee
20. process with this specially designed and sterile disposable blood lancet that is inexpensive easy and fast ri to use Available in a wide variety of ize animals and volumes required Developed for researchers that requested a shorter point for use on very young mice and mice of all ages where only one or two drops of blood are needed The shorter the point length the less pain and trauma for the animal and the quicker the healing gt Safe won t hurt the animal gt Easy to use works every time gt Consistent amounts of blood each test gt Rapid collection blood flow stops in seconds gt Allows multiple tests of the same animal gt Fast Sterile ready for use gt Disposable no cross contamination gt Humane similar lancets are used on humans gt Inexpensive reduce research costs Goldenrod Lancets come in several point lengths for various size animals and blood volumes required Choose the proper lancet point length corresponding to the age of the mouse and the volume of blood needed Point Length Recommendations For Mice 3mm for only 1 or 2 drops 4mm under 2 months omm 2 to 6 months 5 5mm over 6 months 5 5mm 6 mm under 3 months 6mm or 7mm 3 to 4 months 7mm or 8mm over 5 months Always use the shortest point possible to draw the amount of blood required Always be careful when doing multiple bleedings in one day or daily bleedings that the volume of blood harvested does not exceed
21. to explore novel environments ANY maze can perform tests in up to 16 pieces of apparatus simultaneously ANY maze has comprehensive reporting and analysis features including more than 30 built in statistical tests MODEL DESCRIPTION As the name implies ANY maze can be used to track literally any animal 60140 Mouse Plus Maze anywhere Using just a conventional desktop or notebook computer and an 60240 Rat Plus Maze analog USB or FireWire camera user can be up and running User can also Many more mazes available or visit braintreesci com use ANY maze to automate complex systems with multiple cameras and apparatuses MODEL DESCRIPTION 60000 ANY maze Software 60600 ANY maze System with camera and accessories bundle Desktop YEARS 60601 ANY maze System with camera and accessories bundle Laser Laptop SS Braintree Scientific Shop online at www braintreesci com Visit us online at www braintreesci com 6 7 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 68 Microscopes and Loupes Portable Digital Microscope Camera Equip your surgery platform with a portable digital microscope camera Capture a photo real time video time lapsed video project image Ideal for small rodent surgery demonstrations dissections and much more Features a 2 0 USB connection eliminating the need for interface cards or expensive software Easy and convenient to load and use DinoCapture application software
22. won t take MODEL DESCRIPTION up unnecessary space on laboratory or production bench BSP 99M 0 145 to 140m hr gt Includes all advanced functions and programming features of Special order interchangeable motors to achieve different rates BS 8000 family 75 per motor Call for list P E jie smooth linear gradient increasing and decreasing Micro Syringe Adapter pean Micro Syringe Adapter is designed to be used in BSP syringe pumps when MODEL DESCRIPTION l l gt using syringes of 5ml or smaller It is possible to insert two micro syringes BS 8002X Single Syringe Pump BS 8004X Dual Syringe Pump into the adapter Note Rates specified obtained with a 50ml syringe Syringe Heater MODEL DESCRIPTION Heating device for syringes that BSP ADPT Micro Syringe Adapter require temperature controlled dispensing Heats syringe to over Model BSP Single Speed 100 C Temperature sensor in Single speed pumps provide from 40 minutes to 3 days of continuous heating pad Digitally set heater infusion with flow rate dependent on syringe size setpoint setpoint is retained in Model BSP single speed syringe pump is specifically designed to infuse memory Controller will heat fluids at an exact and reproducible flow rate from either glass or plastic syringe and hold set temperature syringes Model BSP syringe pumps are equipped with l i using an on off or PID control gt Automatic shut off switch disconnects power at end of syringe alg
23. 1 ETT 20 05 Replacement parts available online at braintreesci com Intubation Packs For use in conjunction with the Rodent Workstand The intubation packs a rat pack and a mouse pack hold everything needed to directly visualize and quickly intubate with a minimum amount of trauma Each pack is designed to hold all tools and supplies needed to perform quick efficient and minimally traumatic orotracheal intubation of small rodents Intubation packs include specially designed and molded autoclavable intubation speculum lidocaine applicator endotracheal tube guide wire incisor loop and a brief video tutorial of how to perform intubations Rat Pack also contains scissors umbilical tape and mirror for the verification of tracheal intubation Mouse pack includes two sizes of Hallowell s mouse endotracheal tubes Packaged neatly and conveniently in a 13 x 8 x 2 polypropylene organizer box with each compartment labeled for contents and reordering information Can be stored most anywhere and always ready for use MODEL DESCRIPTION RW A3746 Rat Intubation Pack RW A3747 Mouse Intubation Pack RW A3748 MDS Otoscope not rechargeable Uses standard replaceable NICAD batteries RW A3749 Welch Allyn NICAD Otoscope rechargeable Includes charger RW A3754 Welch Allyn LI ION Otoscope lighter and brighter rechargeable Includes charger Replacement parts available online at braintreesci com IN ar 7231BRASCI_NOP
24. 10 uL 20 inj Volume 100 uL 900 850 inj Volume 50 uL 1320 inj Volume SOOUL Maximum and minimum injection rates are based on a saline infusion Performance may vary depending upon viscosity of fluid Injection rates shown represent the maximum rates achievable when either 10 of syringe capacity is injected or when full syringe capacity is injected MODEL BSP 104A DESCRIPTION High Low Speed Precision Microliter Syringe Pump Visit us online at www braintreesci com 63 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 64 a Syringe Pumps 271Programmable Microfluidics Model BSP 99M Multi Speed Syringe Pump UL Listed CE APPROVED Multi speed pumps infuse for times ranging from 20 minutes to 2 weeks Model BSP 99M syringe pump has 99 speeds and is designed for use with readily available glass and plastic syringes up to 50m gt Built in flow chart gt 99 equally spaced infusion speeds gt Calibrated sheet providing flow rates for the major brand syringes gt Automatic shut off gt Sound alarm to signal an empty syringe gt Smoothest microfluidic syringe pump on the market Holds 1 syringe up to 60ml gt Advance per step 4 252232 nanometers gt Infusion rates from 0 008nI hr 0 5m syringe to 2545ul min 140ml syringe gt Available in double syringe BS 4002X version gt Easy to use keypad interface gt Space saving chassis foot print size of only 5 75 x 8 75
25. 100 items per pack 7231 BRASCI_NOPRICE 12 13 12 11 33 AM Page 7 Double Lumen Catheters DLR 4 Now a single vessel puncture or cutdown can provide two access points These catheters allow user to infuse incompatible drugs simultaneously or maintain an IV drip while injecting test agents Draw blood samples from one lumen while infusing down stream without interference interruption or dilution of the sample When user can only get into one vessel Braintree s double lumen polyurethane catheters may save the experiment Includes luer lock hubs Catheters are 6 15cm long and have tie down tabs One lumen opens at the tapered tip The second lumen opens about 0 5 1cm behind the tip DL AS 040 This double lumen catheter has an outer diameter of only 0 040 and consists of an inner SUBL 160 PTFE catheter and an outer MRE040 polyurethane catheter The standard length of this double lumen catheter is 6 with both lumens opening at the proximal tip The distal ends are equipped with luer hubs Supplied non sterile CR DL28 Double lumen intracranial catheter system contains an 11 7cm 28g 0 025 OD distal portion 0 007 ID each lumen polyurethane catheter a bonded connection assembly flared to accept a 27ga needle a 0 003 diameter Teflon coated stainless steel stylet to facilitate placement Individually packaged Supplied non sterile CR DL32 Double lumen intracranial catheter system contains an 11 7cm 32ga 0 01
26. 1ml Serum Gel 00 MT 1350 Micro Tube 1 3ml Citrate 0 ee COLOR CODE White White White White Orange Orange Orange Orange Red Red Red Red TD i UNITS 200 pk 1 000 cs 200 pk 1 000 cs 200 pk 1 000 cs 200 pk 1 000 cs 200 pk 1 000 cs 200 pk 1 000 cs UNITS 1 000 cs 1 000 cs 1 000 cs 1 000 cs 1 000 cs Sample Collection Prepared Micro Tubes with Attached Push Cap Closure gt Skirted conical base and label gt Preparations Serum clotting activator plasma lithium heparin hematology potassium EDTA and coagulation citrate koi Wiig MODEL DESCRIPTION UNITS PMT 1500 PK Serum Gel 1 dml 0 c ee ees 100 pk PMT 1500 CS Serum Gel 1 dml cece eee 1 000 cs PMT 1501 PK Serum soll scx y eee oeeromerseesee4 aeons 100 pk PMT 1501 CS Serum 1 3ml 0 cece ees 1 000 cs PMT 1503 PK Lithium Heparin 1 3ml 0048 100 pk PMT 1503 CA Lithium Heparin 1 3ml 004 1 000 cs PMT 1504 PK EDTA 1 3 Mss c2anscee beni tesancaen Sapa 100 pk PMT 1504 CS EDTA 1 3m ee ees 1 000 cs PMT 1506 PK Citrate 0 5 ml ke ec ce ees 100 pk PMI 1506 GS Citrate 0 5 Ml wvcvisssswrekenseeeeeawr es 1 000 cs A Blue Wax Tissue Processing Disc Makes tissue processing easy and quick Process tissue using a clean blue wax surface Layout pin and trim tissue rane Use for processing inspecting and documenting tissue patholog
27. 51 My Block A personal sized Drybath Benchtop control of sample temperature has never been this easy or economical MyBlock Mini fits almost anywhere and can even be used on the go in cars boats or wherever a 12 volt power source is available Its simple touch pad control with digital display is designed for set and walk away temperature selection and unrivaled accuracy At less than 4 4 inches wide MyBlock Mini is truly the first personal block incubator gt Compact fits in the palm of your hand gt Exchangeable blocks for tubes 0 2 to 50ml gt Clear hinged cover ensures temperature uniformity Technical Data Temperature range Ambient 5 to 100 C Temperature accuracy 0 5 C Temperature increments 0 1 C Temperature uniformity 0 2 C Dimensions 4 4 x 5 9 x 4 11cm x 15cm x 10cm MODEL DESRIPTION BSH200 MyBlock Mini Digital Dry Bath with block lifter Blocks sold separately BSH100 02 Block 40 x 0 2ml or 5 x PCR strips BSH100 05 Block 24 x 0 5ml BSH100 15 Block 15 x 1 5ml BSH100 1520 Block 15 x 1 5 or 2ml BSH100 150 Block 4 x 15ml BSH100 500 Block 2 x 50ml BSH100 A12V Vehicle power adapter sold separately Not compatible with clear cover Digital Dry Bath e n l T 4 Digital performance at analog prices A microprocessor regulates the high wattage heaters to provide precise accurate control Exact desired temp is easily set using arrow keys on
28. B 0 300ml Bellows Bio Vac Chamber gt Protects by offering maximum safety during anesthetic induction eliminates the need for a fume hood gt Animals remain in an anesthetized State without having to evacuate the chamber to remove gas prevents animals from waking up gt Circulates warm air to maintain animals body temperature gt Incorporates a self contained laminar flow system gt Compatible with your existing system gt Cage tilts open for easy insertion of animals gt Emission reduced to 0 02 ppm 100 times lower than NIOSH Guidelines of 2 ppm Virtually no release of isoflurane into the room gt Cage is easily flushed after use MODEL DESCRIPTION EZ 175 Bio Vac Chamber Rodent Inhalation Anesthesia DANEI and Scavenging System Lightweight and portable system allows the user to maintain multiple animals at the same anesthesia level with a single vaporizer while providing excellent scavenging of the anesthetic preventing its release into the room The standard R ADS is configured with two delivery ports and an induction chamber Once the animal is induced with anesthetic it can be transferred to one of the delivery ports where it can be maintained until user is ready to intubate animal and post intubation while animal awaits further treatment Delivery ports can also be used as procedure ports for applications where intubation is not required R ADS is custom configurable to support up to four animals De
29. DESCRIPTION H5600 Revolver Tube Mixer w rotisserie for 36 x 1 5 tubes H5600 02 Rotisserie for 36 x 1 5 2ml tubes included with unit H5600 15 Rotisserie for 10 x 15ml tubes and 16 x 5 7ml tubes H5600 50 Rotisserie for 6 x 50ml tubes GyroMini Nutating Mixer GyroMini is a smaller version of the popular Gyro Twister Its small size makes it ideal for mixing samples in blood and centrifuge tubes GyroMini combines motions of an orbital shaker and a rocker to produce a three dimensional action The result is a thorough yet gentle mixing without foaming Both speed and tilt angle of this small shaker are fixed to provide the optimal level of agitation for mixing samples in small containers GyroMini is supplied with a dimpled mat for holding tubes firmly in place For temperature sensitive samples the GyroMini can be used in a cold room Specifications Speed range 24 rom Motion Pitch 3 D fixed 20 Maximum load 1 75 b 0 8 kg Ambient operating range 4 to 65 C Dimensions 9 75 x 7 5 x 7 24 8cm x 19 1cm x 17 8cm MODEL DESCRIPTION S0500 GyroMini Nutating Mixer with dimpled rubber mat Visit us online at www braintreesci com 45 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 39 AM Page 46 a Mixers and Shakers Benchrocker Vortex Mixer VX 200 Unique CombiCup head has a nonslip surface and accepts single or multiple tubes of various sizes S r P pe D So as With adjustable spe
30. MouseOx and functions without any special equipment or software Pulsar MRI Sensor can be used in any small bore MRI environment The sensor itself is 20 long enabling the MouseOx and computer can be located a safe distance from the MRI device End of sensor contains a 5 fiber optic portion that can be located inside any small bore MRI machine and can be used during imaging without affecting image quality The sensor clips to the animal s foot or thigh D MODEL DESCRIPTION SLS 001300 Pulsar Small Bore MRI Compatible Sensor SLS 001304 Replacement MRI Thigh Sensor SLS 001305 Replacement MRI Foot Sensor Automated Milker for Rat and Mouse Ideal for the analysis of breast milk composition Automated milker provides researchers the ability to collect rat mouse milk directly from the teat Collects milk from lactating mothers by alternating negative and atmospheric pressures through two solenoid valves and a vacuum pump attached to a microcomputer Environmental pollutants in particular carcinogenic substances and endocrine disrupting chemicals are a worldwide concern The influence that these substances have on babies and their development through breast or cow milk is of great concern The ability to gather milk from rats and mice widely used experimental animals will aid in advancement of research in this area MODEL DESCRIPTION 59150 Automated Milker Rat and Mice IN ar 7231BRASCI_NOPRICE 12 13
31. OT cs convenience in installing animal or for performing a procedure and then reliably returned to the same point Available with 18 or 45 non puncture ear bars MODEL DESCRIPTION 51600 Lab Standard 18 Ear bar 51650 Lab Standard 45 Ear bar 51603 Dual Lab Standard 18 51653 Dual Lab Standard 45 Standard Stereotaxic Like the classic Lab Standard the Standard stereotaxic Instrument has larger laser engraved vernier scales accurate to 100um 80mm of ventral dorsal medial lateral and anterior posterior travel absolute lock at 90 ventral dorsal and brass bushings for electrical grounding Available as a digital or motorized model gt Revolutionary vertically adjusting ear and nose bar posts gt Revolutionary horizontally adjusting ear and nose bar posts gt Designed for both rats and mice all on the same base gt No U frame maximizes operating space gt Traditional and non traumatic rat ear bar gt Includes innovative mouse ear bars mouse and rat nose adaptor and dual tip ear bars with tramatic 18 and non tramatic 45 ear bars MODEL DESCRIPTION 51500 Standard Stereotaxic rat and mouse 51500D Digital Standard Stereotaxic rat and mouse 51500M Motorized Standard Stereotaxic rat and mouse 51501 Standard Stereotaxic rat and mouse no manipulator arm 51503 Dual Standard Stereotaxic rat and mouse 51503D Digital Dual Standard Stereotaxic rat and mouse ep S
32. Pig Visit www braintreesci com to see the new additions 80 BRAINTREE SCIENTIFIC 781 348 0768 IN ar
33. Sloped contro panel while values are shown on large digital display No checking of a thermometer and readjusting temp necessary User calibration feature allows for easy calibration An RS232 port is provided for monitoring and recording temperature a Lab Equipment Stainless steel block chamber acts as a heat sink and provides a uniform transfer of heat from heating elements to interchangeable blocks ensuring all samples receive the same temperature treatment regardless of their position in the block gt Stainless steel block chamber gt Single or dual block units available gt Nonporous aluminum with anodized surface gt Thermometer well required only for calibration purposes Specifications Temperature range Ambient 5 to 150 C Temperature resolution 0 1 C Temperature uniformity 0 2 C Temperature accuracy 0 3 C MODEL DESCRIPTION D1100 Digital Dry Bath single block capacity D1200 Digital Dry Bath dual block capacity D1101 Solid block for machining no holes D1102 Block 48 x 0 2ml PCR tubes or 6 x 0 2ml D1102A Block 24 x 2ml tubes D1105 Block 24 x 0 5m tubes D1105A Block 24 x 1 5ml tubes D1106 Block 35 x 6mm tubes D1112 Block 20 x 12mm tubes D1115 Tall 2 x 15ml centrifuge tubes MyBlock HL Mini Dry Bath The MyBlock HL is the first and only mini heat block featuring a heated lid for protecting samples against unwanted condensation and evaporation Both p the block and lid
34. USB Adapter with 6 cable YSWO05 Software Wedge for DOS and Windows including 5 cable fits RS232 Shop online at www braintreesci com 7231BRASCI_NOPRICE 12 13 12 11 41 AM Page 57 T FLEX Plus Gloves Cut resistant gloves for animal handling Gloves are suitable for the safe handling of g small laboratory animals including rodents me J g eee T FLEX PLUS gloves are a 13 gauge seamless knit shell material is Dyneema fa engineered fibers plated with Lycra spandex Thermax and the antimicrobial treatment Alohasan combine to provide a comfortable glove featuring the highest cut resistance Gloves conform to international safety standards for cut resistance MODEL DESCRIPTION SIZE TFL 13G6 T flex Plus handling gloves 008 Extra Small TFL 13G7 T flex Plus handling gloves 008 small TFL 13G8 T flex Plus handling gloves 00 Medium TFL 13G9 T flex Plus handling gloves 008 Large TFL 13G10 T flex Plus handling gloves 00 Extra Large Keviar Deerskin Handling Gloves Black deerskin leather glove lined with 100 fine knit Kevlar May be worn on their own for handling small animals Fabricated for flexibility comfort and safety during long periods of wear Sold as pairs MODEL DESCRIPTION SIZE KVL LTH S Kevlar Deerskin Handling Gloves small KVL LTH M Kevlar Deerskin Handling Gloves Medium KVL LTH L
35. conditioner gt Water level gauge gt Spin venting handport covers gt Humidiguide temperature humidity gauges Accessories include 2 nebulizers humidifier O2 tubing hose fittings and Y Ve hose connectors MODEL DESCRIPTION SIZE DW 1 ICU with Dome Cover and accessories 00 Small DW 2 ICU with Dome Cover and accessories Medium DW 3 ICU with Dome Cover and accessories Large Intensive Care Units Intensive Care Unit with Flat Cover This Intensive Care Unit ICU has been named by researchers as the rodent recovery cage also great for small birds reptiles eggs and newborns Specifications Small 22 25 L x 15 5 W x 6 5 H BS 9 J Medium 31 L x 25 Wx12 25 H Large 39 25 L x 25 Wx12 25 H Flat covered warmers include gt Water conditioner gt Digital thermostat gt Water level gauge to monitor water level within the warmer gt Spin venting handport covers gt Humidiguide temperature humidity gauges gt Divider Accessories include 2 nebulizers humidifier O2 tubing hose fittings and hose connectors MODEL DESCRIPTION SIZE FW 1 ICU with Flat Cover and accessories 0 Small FW 2 ICU with Flat Cover and accessories 00 Medium FW 3 ICU with Flat Cover and accessorieSs 00 Large Unheated Nebulizer O2 Therapy Cage An economical alternative to heated units this unit will fill the need for
36. connecting tubes MODEL DESCRIPTION EZ 7400 Stereotaxic Small Animal Systems EZ AF9000 Auto Flow System Precise consistent preset flow rate from each outlet no variables E Z Auto Flow System offers highly efficient precise gas flow that is easy to use gt Fixed flow rates are set specifically for mice and rats gt Each output is individually controlled with simple on off switch gt Five outputs supply anesthesia to the induction chamber and up to four breathers gt Preset flow rates eliminate need for flowmeters and manual adjustments gt Protocols are easily followed without calculations gt Flow rate is not impacted by the accessories connected gt Precise low flow gas saves money and protects personnel gt Pushbutton oxygen flush purges induction chamber before removing animals System includes gt EZ 190F Auto flow vaporizer unit gt EZ 103A Microflex mouse rat non rebreathing device plus plastic surgery bed gt EZ 178 Mouse Rat sure seal induction chamber gt EZ 258 Charcoal filters 8 gt EZ 320 Oxygen regulator for H tanks gt Mouse Rat nosecones Nosecone plugs 2 plastic surgery beds charcoal filter stand and all connecting tubes MODEL DESCRIPTION EZ AF9000 Auto Flow System Visit us online at www braintreesci com 71 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 72 P Anesthesia Line EZ R20C Oxygen Concentrator ReFresh Anesthetic Eliminates the need for oxygen
37. constant 37 C for 4 hours Each pad measures 8 x 8 x 0 75 MODEL DESCRIPTION 39 DP 3 Deltaphase Pads and 3 Insulators board not included Need a custom size Deltaphase Pad Fax details to 781 843 7932 Deltaphase Operating Board his compact operating board takes advantage of the Deltaphase principle to maintain animal body temperature during surgical or experimental procedures An 8 5 square stainless steel operating surface lies in contact with an activated Deltaphase isothermal p gt pad The underside of the pad is insulated to provide a longer isothermal period Molded wells are provided for sponges instruments and anesthetic apparatus This board was designed by research scientists to be functional durable and easy to clean Its low cost and safety make it appropriate for use in student laboratories The unit is supplied with two Deltaphase pads each pad measures 8 x 8 x 0 75 MODEL DESCRIPTION 39 OP Deltaphase Operating Board 2 Deltaohase Pads and 2 Insulators 39 DP 3 Deltaphase Pads and 3 Insulators only board not included Instruments shown not included 6 Liter Water Bath gt Compact design gt Stainless steel gable cover and Stainless steel seamless chamber gt 550W heating power gt Pilot light to indicate heating solidly constructed with a stainless steel seamless chamber fae resists corrosion A stainless gable cover minimizes evaporation Optional non toxic non me
38. designed so that the level of agitation can be adjusted from gentle rolling through two levels of tumbling to forceful end over end mixing simply by changing the rotisserie position When a rotisserie is inserted horizontally tubes held vertically an end over end motion is produced The unit can then be used for simple rotating or rested on either end to create a tumbling motion Placing Mini LabRoller on end with power switch will create a more vigorous tumbling motion than resting it on opposite end A rocking motion Is achieved by simply inserting pegs to limit movement of the rotisserie to 20 45 or 60 Any of the three available rotisseries can be used as a rocking platform Using supplied rod rotisseries may be mounted vertically tubes held horizontally In all configurations the speed of the rotisserie is fixed at 24 rpm Interchangeable rotisseries hold numerous tube sizes The Mini LabRoller Rotator is supplied with a rotisserie for 36 x 1 5 or 2ml tubes Two additional rotisseries are available separately Specifications Motion speed Rotating rocking tumbling Speed 115V 230V 24 20 rom Operating Temperature 4 to 40 C MODEL DESCRIPTION H5500 Mini LabRoller Rotator with rotisserie for 36x1 5 2ml tubes H5500 02 Rotisserie for 36x1 5ml tubes H5500 15 Rotisserie for 10x15ml and 12x5ml tubes H5500 50 Rotisserie for 6x50ml tubes Other models and capacities available online or by email Please visit www brai
39. easy access for many types of research applications especially obesity studies Rodent can quickly be inserted into restrainer by removing several stainless Steel upper rods or through an access port hole in rear upright Access port hole features a polycarbonate locking door to prevent escape Front guillotine style door can be adjusted and locked by using any one of three adjustment positions The door has a stainless steel spring loaded lock Suction cup feet on white plastic base secure the device during use gt Weight range from 250 up to 750 grams gt Maximum length of the rodent compartment is 9 228mm gt Eighteen 18 stainless steel rods are adjustable up to 3 5 89 mm gt Rear access port opening is 2 50 8 mm Polycarbonate locking door is attached by a Nylock fastener to prevent future operational loss gt Overall height is 11 279 mm gt Base size is 10 x 12 254 mm x 305 mm gt Basic unit is constructed of 0 5 12 7 mm jeweled acrylic MODEL DESCRIPTION POR 530 Bowman Style Rodent Restrainer Visit us online at www braintreesci com 17 7231BRASCI_NOPRICE 12 13 12 11 36 AM Page 18 P Feeding Needles and Equipment Animal Weight Range Ball Diameter Sterile Malleable Disposable Mice 25 1509 1 25mm Feeding Needles Rats 100 400g 2 2omm ee ee Rats 350 5009 3 00mm Other over 450g 400mm Reuseable Feeding Needles i a E MODEL GAUGE LENGTH BALL
40. filter guard reduces solarization and protects UV filter extending its service life up to 5000 hours Specifications UV light source wavelength 302nm Intensity settings Normal 100 Low 80 Large viewing surface 21 x 26cm Cabinet dimensions 18 5 x 13 4 x 4 3 47cm x 34cm x 11cm MODEL DESRIPTION U1000 Dyna Light UV Transilluminator MODEL E2020 SDB R1000 100BP R1000 1KB 52 BRAINTREE SCIENTIFIC 781 348 0768 a ENDURO Gel XL Includes all components necessary to cast and run horizontal gels gel trays combs casting stand gel tank and digital power supply Migration tank gel trays and multichannel combs are molded for leak proof performance and a long service life Direct connection of power supply into gel box eliminates need for power leads Pressing eject button separates the gel box and power supply Reconnecting is easy just press two pieces together Power supply can be set to either constant voltage or constant current with automatic crossover between the two parameters Parameters are shown on large digital display that is easily visible from a distance Three different gel options for the ENDURO Gel XL 12 5 x 12cm 12 5 x 6cm and 6 x 6cm One larger gel with multiple combs will accommodate up to 112 samples or run two small gels or four micro gels at the same time Cassettes protect fragile electrodes from damage and allow for easy replacement A magnetic sensor allows current to
41. fit into the tightest spaces which would be impossible to clean by traditional methods When bubbles implode water hits the instrument at speeds up to 250 mph providing a very powerful cleaning action gt High capacity elongated tank easily accommodates long surgical instruments and other equipment that may not fit into desktop ultrasonic cleaners gt Uses a powerful generator to create ultrasonic waves that provide effective cleaning action When heavy bio burden or oily residue is present Sentry s cleaning power can be enhanced with a heating feature that warms water up to 65 C gt Operates quietly without disrupting work in laboratory Lid decreases noise and includes a viewing window to monitor progress gt Takes up little space for convenient storage on lab bench Light weight for easy transport or storage MODEL DESCRIPTION ULTRA 9911 Sentry Ultrasonic Cleaner Visit us online at www braintreesci com 55 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 41 AM Page 56 Scales and Balances 271 Core Compact Portable Balances gt Full range tare gt 9 weighing units gt Zero tracking gt Simple 4 button operation gt Backlit LCD display gt Stainless steel pan gt ShockProtect overload three point protection gt Can be stacked for storage 120mm pan size only gt Lock down mounting slot for Kensington type lock and cable gt Dual tare keys gt Lightweight and portable gt Modern lo
42. for 10 standard 1 5 2ml microtubes and one 96 well PCR plate or 0 2ml tubes strips The other side can be used to hold 36 standard 1 5 2ml microtubes MODEL DESCRIPTION R1000 CoolCube Microtube and PCR Plate Cooler YEARS 1980 2012 a ric AX Braintree Scientific 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 39 Blue Graduated Measuring Cylinders Tall form PMP Conforms to ISO 6706 1981 E and BS 5404 Part 2 1977 Crystal clear Autoclavable Can be used for liquids up to 170 C No wetting No meniscus Permanent graduations MODEL CAP GRAD TOL oD H QTY PK K2570 10ml 0 2ml 0 2 13 5mm 139mm 20 K2573 100ml ml 1 3imm 249mm 1 K2576 1000ml 10ml 10 66mm 438mm 4 K2577 2000ml 20ml 20 84mm 531mm 2 K2571 25ml 0 5ml 0 5 18 5mm 195mm 20 K2574 250ml 2ml 2 41 5mm 315mm 8 K2572 50ml ml 260mm 199mm 20 K2575 500ml 5ml 5 55mm 361mm 6 Blue Graduated Beakers Low form PMP Conforms to ISO 7056 1981 E and BS 5404 Part 1 Crystal clear Autoclavable Will withstand 170 C for short periods Permanent graduations are molded in for reproducibility Excellent chemical resistance WALL MODEL CAP GRAD TOL O0D H THICKNESS QTY CS K1543 100m 5mi 10 52mm 72mm 1 5 48 K1548 1000m 20mi 10 110mm 146mm 1 8 12 K1541 25ml qmi 10 34mm 49mm 1 3 40 K1545 250mi 10mi 10 71mm 95mm 1 7 32 K1530 3000mI 500ml 10 159mm 201mm 2 5 2 K1542 50ml 2ml 10 42mm 60mm 1 3 40 K1546 500ml 10m
43. funnels two water spillage tubes and two urine collection tubes two feces collection tubes and two urine rings All cages require support stand MODEL DIMENSION MTB 0100 Metabolic Cage for Rats 150g to 300g Overall nom dim L x W x H 14 x 11 x 19 36cm x 28cm x 48cm Domicile portion nom dim I D x Ht 8 x 5 5 20cm x 14cm Area sq in Sq cm 50sq 320 sq cm Metabolic Cage for Rats under 150g Overall nom dim L x W x H 14 x 11 x 19 36cm x 28cm x 48cm Domicile portion nom dim I D x Ht 8 x 5 5 20cm x 14cm Area sq in Sq cm 50sq 320 sq cm Metabolic Cage for Mice Overall nom dim L x W x H 14 x 11 x 19 36cm x 28cm x 48cm Domicile portion nom dim I D x Ht 8 x 5 5 20cm x 14cm Area sq in Sq cm 50sq 320 sq cm Contact us if you would like to modify your existing cage to house smaller rodents MTB 0210 MTB 0311 Diuresis Metabolic Cage for Mice For collection of by products from a single mouse Smaller separating cone and collection funnel minimize evaporation Stainless steel screen replaces the collection tube for feces separation Same upper chamber dimensions as above Includes feeder assembly water bottle with cap and bottle support All cages require support stand MODEL DIMENSION MTB 0322 Overall nom dim L x W x H 14 x 11 x 19 36cm x 28cm x 48cm Domicile portion nom dim I D x Ht 8 x 5 5 20 x 14cm Area sq in sq cm 50sq 320 sq cm
44. gt Fully skirted for automated handling for ABI thermal cycler compatibility as F A e aa pa VS gt Sealing options Heat sealing adhesive Ses a A l sealing PCR cap strips j gt Recommended for use with low volume reactions lt 20uL JE ESCARTON gt Sealing options Heat sealing adhesive sealing PCR cap strips SP0446 Box with 5 packs of 5 each MODEL re f i SP0037 Box with 5 packs of 5 each Semi Skirted Flat Deck gt Semi skirted plate designed specifically for i 384 Well PCR Plate ABI thermal cycler compatibility S Skirted gt Flat deck for improved handling and sealing eitel taining gt Sealing options Heat sealing adhesive ree gt 40uL maximum well volume sealing PCR cap strips l 2ouL working volume ii MODEL DESCRIPTION gt SBS footprint gives broad range thermo cycler compatibility mep a ee gt Sealing Options Heat sealing adhesive sealing i MODEL DESCRIPTION Low Profile Non Skirted SP0017 Box with 5 packs of 10 each gt Designed to reduce dead space and prevent teen wall Ss 96 Well Plate gt Maximum well volume 200i eRe w meee ts gt Recommended for use with low volume Dee esn 370l Round Well U Bottom reactions lt 20uL 79 gt U bottom aids in resuspension supporting gt Sealing options Heat sealing adhesive sealing PCR cap strips ribs increase centrifugation strength MODEL DESCRIPTION gt Sealing options Heat sealing and adhesive sealing SP0029 Box with 5 Packs of 5 each MODEL DESCRIP
45. gt Insertion of a needle into the tail vein can be confirmed by the reflux of the imitation blood Techniques gt Retention gt Peroral dosage gt Tail intravenous dosage and blood collection gt Endotracheal intubation MODEL DESCRIPTION KOKEN MODEL KOKEN Rat Model KOKEN TAIL Replacement Tail for KOKEN Rat KOKEN BLOOD Replacement Blood for KOKEN Rat Electronic Atlas k T Histopathology of Chemically Induced Tumors An exact replica of the Soft Science Publications atlas published in 1987 by the same name It contains about 650 color photos and corresponding text It is a unique collection of excellent color microphotographs of almost all lesions found in experimental animals treated with chemical agents It is a very useful reference for experimental pathologists cancer researchers and toxicologists MODEL CD LALES DESCRIPTION Histopathology of Chemically Induced Tumors Visit us online at www braintreesci com 79 LD ar 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 80 a Reference Books Anatomy of the Rat Handbook of Laboratory Animal By Eunice Chace Greene Science Volumes I Il and Ill kiii Editors Per Svendsen Odense University Denmark Jann Hau S i a i The Royal Veterinary College London U K This three volume set presents a comprehensive description of laboratory animal genetics diseases health monitoring nutrition and environmental impact on animal testing It consid
46. hours 59 mininutes 50 seconds 1 minute increments Dimensions 14 x 13 x 18 6 35 5cm x 33cm x 47 4cm Weight 66 Ibs 30 kg rom Open lid and rotor quickly decelerates to a stop for removing samples An increased capacity eight position microtube rotor is included and comes installed A second rotor for 0 2ml PCR tubes and strips is also included and Stored with rotor removal key in a convenient compartment on bottom of the centrifuge A include microtube rotor PCR rotor 0 5ml and 0 2m adapter MODEL DESCRIPTION C1008 B MyFUGE Mini Centrifuge blue lid Cl 008 C MyFUGE Mini Centrifuge clear lid C1008 G MyFUGE Mini Centrifuge neon green lid C1008 P MyFUGE Mini Centrifuge purple lid C1008 R MyFUGE Mini Centrifuge red lid 42 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 39 AM Page 43 a My Fuge 12 Mini Centrifuge gt COMBI Rotor for tubes and strips gt Twice the capacity of traditional mini centrifuges gt Near silent operation gt Starts and stops with opening closing of lid Unlike traditional mini centrifuges the MyFuge 12 eliminates the need to change rotors when switching between microtubes and PCR strips The included unique COMBI Rotor is all that is required for running 12 microtubes and 4 PCR strips simultaneously With a fixed speed that produces 2 000 xg this centrifuge is perfect for quick spin downs Simply close lid and unit quickly ramps up to 5500 rpm
47. is a rodent A pme ia restraint device used for I V ee tail vein blood collection and injection The unit rests on a sturdy steel base which keeps it from moving during injection The restraint cylinder is raised from the base in order to provide a more ergonomic working position for the user Tail vein blood collection can be very difficult in rats and mice The cylinder allows the user access to both tail veins by use of a hinge which is connected under the cylinder If the user misses one vein they can flip the unit over which will allow access to the other vein The rat unit also features a removable door which allows the user to load the animal forward causing less stress on the rat MODEL DESCRIPTION HFR M Howard Flip Restrainer for Mice HFR R Howard Flip Restrainer for Rats up to 450g Universal Restrainer Experiments made easier ty n oe gt Adjustable Unique spiral grip makes single size restrainers obsolete gt Low stress Gentle but secure Rats can not turn or escape natural posture maintained gt Easy to use Complete experimental access gt Stable and strong Wide base stands up to daily use heavy construction gt Easy to clean Opens fully will not corrode no blind ends Plastic and Stainless steel construction gt Improved technique Save time and effort when handling laboratory rats User has both hands free Relax and avoid accidents knowing animals are gently but firmly restrained MODEL
48. maintenance of health study records and management of colonies of laboratory animals This instrument is in compliance with regulatory agencies and research protocol requirements for care and use of laboratory animals Advantages gt Permanent mark is easily readable on pigmented or albino animals gt Humane gt Rapid and easy to apply gt Almost infinite ID numbers gt Sterile and disposable hypodermic needles prevent spread of potentially infectious disease gt Inexpensive Instructions gt Choose the needle gt Fill ink tank gt Immobilization gt Squeeze instrument gt Identification with grid location The needle is re inked when it enters the ink tank on the other side Discomfort of animal is minimal and equivalent to a quick injection with a very fine needle Kit includes gt 1 oz of Ketchum green tattoo paste gt 1 aluminium planchette gt Plastic holding case gt 2 practice hypodermic needles MODEL DESCRIPTION MTK ARAMIS Complete Microtattoo Kit MTP 1 Green Tattoo Paste 1 oz MTP 5 Green Tattoo Paste 5 oz 33 Visit us online at www braintreesci com LD ar 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 34 Sample Collection Blood Collection for Facial Vein Submandibular Blood Samples GoldenRod Animal Lancet allows user to take multiple blood samples from small animals in the same day and never lose or hurt an animal speed up the blood collecting
49. metabolic cage Stand supports one cage and provides easy access to all parts 12 cage racks and refrigerated collection racks are also available All stands and racks are sold separately gt Collection Funnel and Separating Cone Unique design and non wetting PMP ensure immediate complete separation of feces and urine gt Support Grid SS grid lets excreta pass through the widely spaced bars mouse cage includes mouse size grid Grids have handles for easy transport of cage without stand gt Water Bottle Calibrated PC bottle with SS cap and sipper tube gt Water Spillage Tube Collects any water that animals spill Facilitates accurate collection of fluid intake data gt Each cage includes complete assembly and use instructions replacement parts list and warranty card Designed for rats guinea pigs and hamsters Includes same fluid collection tubes and rings as the smaller rodent cages and the following components sized for larger rodents upper chamber water bottle and support feeder assembly and urine collection tube All cages require support stand MODEL DIMENSION MTB 0350 Metabolic Cage for Large Rodents 300g to 850g Overall nom dim L x W x H 14 x 11 x 20 5 36cm x 28cm x 52cm Domicile portion nom dim D x Ht 9 5 x 7 24cm x 18cm Area sq in Sq cm 70sq 450 sq cm 76 BRAINTREE SCIENTIFIC 781 348 0768 a Includes appropriate feeder drawer and chamber four fluid collection tubes with
50. rate can be changed while pumping gt Remembers previous settings on power up gt Power failure mode allows pump to continue pumping after a reset gt Syringe purge mode gt Displays total volume dispensed in ml or uL units gt Maximum pumping rate of 1500ml hr with a 60ml syringe gt Precise reproducible flow rates gt Selectable infusion rate units ml hr uL hr ml min uL min gt Infuses only gt Just the features that you want to pay for MODEL DESCRIPTION BS 300 Just Infusion Syringe Pump High Low Speed Precision Microliter oe Syringe Pump gt Uses high quality Hamilton Micro liter glass syringes to ensure precise accurate delivery gt Supports three syringe sizes 10uL 100uL and 500uL gt Wide range of injection rates are possible gt Unprecedented injection speeds are possible For example using a 500 uL syringe an injection volume of 100 uL can be delivered in under 100 ms gt Able to inject the entire syringe volume during a single injection gt USB operation facilitates use no extra controllers are required The classic high speed Microliter Syringe Pump designed to meet the need in laboratories for rapid infusion of addictive compounds especially nicotine Typical Maximum Injection Speeds MAX RATE AT 10 SYRINGE SYRINGE SIZE uL CAPACITY uL SEC MAX RATE AT FULL SYRINGE CAPACITY LSEC 10 19 inj Volume 1 uL 32 inj Volume 10uL 100 190 inj Volume
51. rom or g force Pressing knob toggles display between rom and rcf Turning timer knob sets time parameter while pushing it starts and stops operation of unit Last run settings remain in memory allowing for repetitive centrifuging without resetting of parameters Extremely quiet and cool running this unit maintains a small footprint spectrafuge 24D is available in five accent colors gt Supplied with rotors for 1 5 2ml tubes and 0 2ml PCR strips Specifications gt 6000 ropm 2000 x g Speed range 500 rpm to 13 300 rom gt On off switch Maximum RCF 16 300 xg gt Durable lid hinge Maximum capacity 24 x 1 5 2ml gt 6 x6 153mm x 153mm footprint Timer 0 to 30 minutes or continuous Quick button for gt Available in five different lid colors momentary operation Ideal for quick spin downs and micro filtration Each unit is supplied with a Dimensions 9 25 x 11 5 x 8 5 23 5cm x 29 3cm x 21 6cm 6 x 1 5 2ml rotor and adapters for 0 5 and 0 4ml tubes as well as a rotor MODEL DESCRIPTION that will hold 2 x 0 2ml strip tubes such as those used for thermal cycling C2400 B Spectrafuge 24D blue accents Maximum speed is 6000 rpm corresponding to 2000 x g in the six place C2400 T Spectrafuge 24D teal accents C2400 P Spectrafuge 24D purple accents rotor Each unit has an on off switch allowing the user to stop motion of C2400 R Spectrafuge 24D red accents rotor before opening centrifuge lid Lid hinge design incorporate
52. strip tube rotor Specifications 0 5 and 0 4ml adapters red lid Capacity 2 PCR Plates Rotor speed 2500 rom Spectrafuge 24D Digital G Force 500 xg M icrocentrifuge Rotor Fixed Vertically Dimensions 7 5 x 8 2 x 7 2 19cm x 21cm x 18 3cm MODEL DESCRIPTION C1000 Mini Plate Spinner Welcome to the high end of the performance spectrum gt Complete with easy access 24 x 1 5 2ml rotor gt Set and view speed in rom or g force gt Digital set and display of parameters gt Quiet and cool running Easy access 24 x 1 5m rotor is supplied with the Spectrafuge 24D Innovative rotor places tubes on a plateau where user can easily grip their tops Powerful brushless motor quickly accelerates rotor to a maximum speed of 13 300 ropm 16 000 x g Controls are simple consisting of only 44 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 39 AM Page 45 Mini LabRoller Rotator Economical solution for tube mixing Compact and sleek design A small footprint and efficient housing design conserve valuable bench space and make Mini LabRoller Rotator suitable for any size laboratory It has an ambient operating range of 4 40 C and will easily fit into most incubators Lightweight and portable the unit is easily moved from the bench to a biological or chemical hood simple construction allows for easy cleaning and decontamination Wide range of motion The Mini LabRoller Rotator is uniquely
53. the total volume recommended for that size animal s safety and health point sizes for various s For Rats MODEL DESCRIPTION GR 3MM Goldenrod Animal Lancet 3mm Sterile 5 trays of 200 GR 4MM Goldenrod Animal Lancet 4mm Sterile 5 trays of 200 GR 5MM Goldenrod Animal Lancet 5mm Sterile 5 trays of 200 GR 5 5MM Goldenrod Animal Lancet 5 5mm Sterile 5 trays of 200 GR 6MM Goldenrod Animal Lancet 6mm Sterile 5 trays of 200 GR 7MM Goldenrod Animal Lancet 7mm Sterile 5 trays of 200 GR 8MM Goldenrod Animal Lancet 8mm Sterile 5 trays of 200 A full selection of Sarstedt tubes is available please email info braintreesci com for details and pricing 34 BRAINTREE SCIENTIFIC 781 348 0768 a Microvette 100 200 Provides all the benefits of a universally suitable capillary blood collection system The Microvette 100 200 offers the ideal solution for collection of even the smallest blood volumes Preassembled end to end capillary ensures a controlled collection to capillary technique The Microvette enables blood sampling using either the special rim or gravity flow principle without any problem Depending on individual requirements the Microvette is available with a cylindrical inner tube for optimum mixing results or a conical inner tube for a high serum plasma supernatant Cylindrical outer container is ideal for barcodes and patient labels Special cap design minimizes aerosol effect when tube is opened and provide
54. thicknesses and sizes while platinum coated electrodes provide uniform pressure ensuring even transfers For total blotting solutions use with ENDURO 250V 3000mA high current power supply gt Western Southern and Northern blots gt Rapid transfer times gt Uniform head dispersion gt Variable gel thickness gt Minimal buffer volume Specifications Buffer Volume 20ml Sample Capacity 4 Blots 8 x 8 5cm 2 Blots 16 x 8 5cm 1 Blot 16 x 17 5cm DESCRIPTION Enduro Semi Dry Blotter Enduro MW Marker 100 bp ladder 100 2 000 bp 0 1ug ul 500 vial Enduro MW Marker 1 kb DNA ladder 300 10 000 bp 0 1ug ul 500u vial DyNA Light UV Transilluminator With its dual intensity light source the DyNA Light UV Transilluminator is suitable for both analytical and preparative work Large viewing surface accommodates all popular gel sizes The intensity of the DyNA Lights 302 nm UV light source can be adjusted to two levels normal and low at the touch of a button Low setting provides a 20 reduction in intensity to minimize damage to nucleic acids during longer exposures Full intensity produces clear and bright illumination for documentation work Users are protected by a hinged transparent shield of UV blocking acrylic that covers the top surface of the transilluminator Cover can be raised to proper angle for viewing samples and lowered when not in use to protect viewing surface from dust and scratches Built in
55. to accept appropriate periods of confinement in the ECU Blood pressure clearance and metabolism studies are better and easier using ECUS ECU consists of a molded plexiglass canopy hinged to a plexiglass base Canopy has a tapered opaque plastic hood to protect the animal from visual disturbances Multiple slots and an end plate allow adjustment of the canopy length for animal size and easy access to dorsal catheters and electrical leads The base has a large through drilled slot for accessing ventral catheters feces and urine Four comfortable slots are provided to support the feet The Braintree Scientific ECU is set up in position with the required equipment The animal is placed in the ECU and the catheters and leads connected to the appropriate devices Our ECU has been used for studies of anti hypertensive drugs development of hypertension as a function of age renal and drug clearance metabolism and endocrinological studies ECU units are tailored for different sizes of rats and mice as a function of CA body weight For best results animals should be conditioned to appropriate periods of confinement in the ECU This is easily achieved by introducing animals to the ECU daily for increasing periods of time MODEL DESCRIPTION G 05 ECU less than 50g G 1 ECU 50 to 120g G 2 ECU 120 to 250g G 3 ECU 250 to 350g G 4 ECU 350 to 400g G 5 ECU 400 to 800g Economy Flat Bottomed Restrainers Individual semicylindrical plastic res
56. transparent to help user locate and remove such bubbles Small clots can block pressure catheters and prevent pulse waves from reaching the transducer Since RenaPulse has the superb blood compatibility of Micro Renathane the chance of clot formation is greatly reduced These features make RenaPulse the tubing of choice for high fidelity pressure measurements in small animals RenaPulse is flexible enough for direct vessel insertion It can be bonded to luer lock terminations and stopcocks RenaPulse can also be used with standard compression adapters or needle stubs Supplied non sterile MODEL DIMENSIONS RPT 033 0 033 OD x 0 014 ID 0 84 OD x 0 36 ID mm RPT 037 0 037 OD x 0 023 ID 0 94 OD x 0 58 ID mm RPT 040 0 040 OD x 0 025 ID 1 02 OD x 0 64 ID mm RPT 080 0 080 OD x 0 040 ID 2 03 OD x 1 02 ID mm Kit includes 12 individually packaged 3 ft lengths tMinimum 36 feet when ordering continuous lengths More length options available online at braintreesci com 7231BRASCI_NOPRICE 12 13 12 11 32 AM Page 3 Blunt Tip Catheter Needles Stainless steel blunt tio hypodermic needle with standard luer hub For use as an interface to connect a hypodermic syringe directly to catheter port for intravascular substance administration blood sampling and catheter flushing MODEL DIMENSIONS NB 30 30 gauge 0 5 NB 27 2 gauge 1 NB 26 26 gauge 0 5 NB 25 25 gauge 1 NB 23 23 gauge
57. x 8 3 x 5 3 17cm x 21cm x 13 5cm MODEL DESCRIPTION D1030 BeadBug Microtube Homogenizer Prefilled Tube Kits non skirted with caps MODEL DESCRIPTION BEAD SIZE QTY D1031 01 Standard Glass Beads 0 0 1mm 50 pk D1031 05 Standard Glass Beads 0 0 5mm 50 pk D1031 10 Standard Glass Beads 1mm 50 pk D1032 01 Triple Pure High Impact Zirconium Beads 0 1mm 50 pk D1032 05 Triple Pure High Impact Zirconium Beads 0 5mm 50 pk D1032 10 Triple Pure High Impact Zirconium Beads 1mm 90 pk D1032 15 Triple Pure High Impact Zirconium Beads 1 5mm 50 pk D1032 30 Triple Pure High Impact Zirconium Beads 3mm 90 pk D1033 28 Stainless Steel Acid Washed beads 0 2 8mm 50 pk D1032 SK Triple Pure High Impact Zirconium Beads Starter Kit 0 1 0 5 1 1 5 and 3mm 10 each 54 BRAINTREE SCIENTIFIC 781 348 0768 a wW Bullet Blendere Homogenizer Aim for higher efficiency superior results and greater value Versatile Bullet Blender is ideal for a wide range of laboratory tasks including disrupting homogenizing dissociating or lysing cells tissues and plant matter Thousands of researchers rely on this high quality instrument to achieve consistent results while saving time effort and money gt Easy operation simply add samples beads and buffer to tubes and place in Bullet Blender Select run time and speed close the lid and press start No clamp plates or locking rings to fiddle with gt High efficiency technol
58. your new animal fixation system Providing an option for scientists who would rather do science than design a system and source parts Let AutoMate take the guesswork out of your new animal fixation system Steady gravity fed delivery of buffer and fixative results in complete perfusion Easy to set up use and clean Complete system with everything down to the needles Fits in standard hoods at a fraction of the cost of a peristaltic pump and more reliable One or two users can perfuse two mice simultaneously with the Double In Vivo system ALZET pumps are miniature delivery systems designed to provide constant accurate administration of test agents These self powered pumps offer a convenient and efficient method for long term dosing of mice and rats Pumps are sold empty and are easily filled with your test agent via syringe self powered pumps are then implanted either subcutaneously or intraperitoneally Eleven pump models offer a range of release rates and durations to meet your specific research needs Continuous delivery of up to 4 weeks is feasible with a single pump and even longer durations can be achieved through serial implantation of pumps Pumps sold in multiples of 10 Each package comes complete with one filling tube 10 flow moderators and detailed instructions MODEL DESCRIPTION AP 1003D 1uL hr 3 days 100uL AP 1004 0 11uL hr 28 days 100ml AP 1007D 0 5uL hr 7 days 100uL AP 1002 0 25uL hr 14 days
59. 100 yds D Spools with swagged needles MODEL DESCRIPTION SIZE MATERIAL LENGTH S 1074 0 375 circle reverse cutting 3 0 Silk 18 S 7116 0 5 circle taper point double needle 4 0 Silk 24 S9 403 Straight taper 3 0 Silk 30 Vascular Ports and Clamps k T Microport for Vascular Access Specifications Uses For mice larger than 10g Housing size 0 124 H x 0 35 L x 0 37 W 3 15mm H x 9mm L x 9 1mm W Punctures 100 cycles with a 27ga needle Weight 0 10g Dead Space 0 010cc including catheter Catheter length 4 40cm 1 75 Catheter size 0 54mm 0 021 Catheter material Stainless steel MODEL DESCRIPTION MICROPORT Microport for Vascular Access in Mice Micro Clip Setting Forceps MODEL DESCRIPTION FC148 475 L Micro Vascular Clips MODEL OCCLUSION PRESSURE VESSEL DIA LENGTH MVC 00 10 159 1mm 8mm MVC 02 15 209 1 2mm 11mm MVC 04 20 309 2 3mm 14mm Small Port Specifications Uses For rodents to very small animals Housing size 0 24 H x 0 88 L 6mm H x 22mm L Punctures 1500 cycles with a 22 gage non coring needle Dead space 0 030cc Catheter length 25cm 10 Catheter size 3 French Catheter material Polyurethane or silicone Tip to first bulb distance 35mm or 60mm MODEL DESCRIPTION S ISC 35P Port Polyurethane 35mm bulb distance S ISC 60P Port Polyurethane 60mm bulb distance S ISC 358 Port Silicone 35mm bulb distance S ISC 60S Port Silicone 60mm bulb distance Vi
60. 100uL AP 2001D 8uL hr 1 day 200uL AP 2001 1uL hr 7 days 200uL AP 2002 0 5uL hr 14 days 200uL AP 2004 0 25uL hr 28 days 200uL AP 2006 0 15uL hr 42 days 200uL AP 2ML1 10uL hr 7 days 2ml AP 2ML2 5uL hr 14 days 2ml AP 2ML4 2 ouL hr 28 days 2ml Filling Tubes Filling Tubes supplied in multiples of 10 MODEL DESCRIPTION A FT100 Filling tube for 100 microliter pumps A FT200 Filling tube for 200 microliter pumps A FT2 Filling tube for 2 milliliter pumps For pricing visit braintreesci com Perfusion System gt Four reservoirs and two stopcocks are mounted for two independent wash buffer and fixative deliveries on the same ringstands gt 2 way manual stopcock makes for easy one handed operation to switch solutions gt Consistent results steady gravity fed delivery of buffer and fixative results in complete perfusion gt Easy to set up use and clean complete system with everything down to the needles Fits in standard hoods gt Fraction of the cost of a peristaltic pump and more reliable MODEL DESCRIPTION IV 140 InVivo Perfusion System 140ml Mouse lV 800 InVivo Perfusion System 800ml Rat IV 4140 Double InVivo Perfusion System 4x 140ml Double Mouse Osmotic Pumps Brain Infusion Kits Many agents do not cross the blood brain barrier sufficiently to i evaluate their effects on the brain F Ry without administration directly into brain Often local infusion directly into brain is only
61. 12 11 42 AM Page 67 P Physiology Equipment ANY maze Behavioral Tracking Water Maze Software Impressively flexible incredibly simple intensely powerful Water Maze is a behavioral procedure designed to test spatial memory gt Track literally any animal anywhere Maze es l gt Intuitive friendly design gt oo of local cues such as trace scents gt Includes more than 100 standard measures gt No fixed escape formula gt Performs full statistical analysis of results immediately upon completion of your experiment gt Comprehensive technical support gt Tracks up to 16 pieces of apparatus simultaneously amp x l MODEL DESCRIPTION gt Incredibly low price 60135 Mouse Water Maze 60136 Mouse Rat Water Maze 60235 Rat Water Maze Forced Swim Test Forced Swim Test also known as the behavioral despair test is the most a commonly used test for assessment of Sa ME depression in animal models The test is z commonly used to measure the effect of antidepressant drugs on behavior gt ANY maze Behavioral Tracking Software ANY maze can automate testing in a wide variety of behavioral apparatuses UH iN lt MODEL DESCRIPTION 60160 Forced Swim Test P Elevated Plus Maze Elevated Plus Maze is used to assess anxiety like behavior in laboratory animals The maze exploits the conflict between the innate fear that rodents have of open areas versus their desire
62. 15 x 0 05mm SUBL 080 0 008 x 0 004 0 20 x0 10mm 0 002 20 ft coil SUBL 120 0 012 x 0 006 0 30 x0 15mm 0 003 20 ft coil SUBL 140 0 014 x 0 008 0 36 x0 20mm 0 003 20 ft coil u iT THICKNESS LENGTH 0 002 20 ft coil SUBL 160 0 016 x 0 010 0 41 x0 25mm 0 003 20 ft coil SUBL 190 0 019 x 0 013 0 48 x 0 33mm 0 003 20 ft coil SUBL 220 0 022 x 0 016 0 56 x0 41mm 0 003 20 ft coll 2012 Zeus Industrial Products All rights reserved RenaPulse High Fidelity Pressure Tubing Measure blood pressure and waveforms more accurately while keeping superb biocompatibility RenaPulse tubing exclusively from Braintree Scientific is made from a new material which transmits pulse waveforms with high fidelity During pressure pulses fluid flows into the catheter and depresses the diaphragm of a pressure transducer However the same pressure wave that reaches the transducer also causes the pressure catheter to bulge slightly This bulging may allow a significant volume of fluid to flow in and out of the catheter with each pulse Given the resistance of the catheter this small flow can lead to pressure drop along the catheter and inaccurate pressure readings from the transducer RenaPulse is a stiffer tubing which allows high fidelity measurement of systolic and diastolic pressures Because air bubbles in pressure catheters are very soft they can completely distort the pulse wave We make RenaPulse tubing
63. 151673 CS Plasma Lithium Heparin 1000 cs MLT 151675 BX Plasma Gel Lithium Heparin 100 pk MLT 151675 CS_ Plasma Gel Lithium Hepari 1000 cs MLT 151671 BX Hematology Potassium EDTA 100 pk MLT 151671 CS Hematology Potassium EDTA 1000 cs MLT 151672 BX Glucose Flouride 00 e eee 100 pk MLT 151672 CS Glucose Flouride 00 00 ee Minivette POCT Easy sample recovery due to optimal capillary features 5 gt Precise dispensing of small whole blood volumes gt Prevents spillage during transfer to test card gt Available in 20ul and oOul volumes gt Preparations Neutral heparin and EDTA MODEL DESCRIPTION MP20 2111 PK 20 ul neutral MP20 2111 CS 20 ul neutral MP50 2111 PK 50 ul neutral MP50 2111 CS 50 ul neutral MP20 2112 PK 20 ul Lithium Heparin MP20 2112 CS 20 ul Lithium Heparin MP50 2112 PK 50 ul Lithium Heparin MP50 2112 CS 50 ul Lithium Heparin MP20 2113 PK 20 ul EDTA MP20 2113 CS 20 ul EDTA MP50 2113 PK 50 ul EDTA MP50 2113 CS 50 ul EDTA Prepared Micro Tubes with Screw Cap Closure gt Closure contains integral O ring gt Sample volume 1 3ml gt Skirted conical base gt Label MODEL DESCRIPTION MT 1392 Micro Tube 1 3ml Serum Clotting Activator MT 1393 Micro Tube 1 3ml Plasma Lithium Heparin MT 1395 Micro Tube 1 3ml Hematology Potassium EDTA MT 1378 Micro Tube 1
64. 2 Nail PR Braintree Scientific p 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 79 MD PVC Rat Microsurgical Developments PVC Rat is an example of the replacement of living animals Microsurgical Developments PVC Rat is developed to master skills in microsurgery Using the model during training of scientists and animal technicians the number of live animals needed will be reduced drastically It gives the possibility of training approximately 25 different microsurgical techniques i e anastomoses cannulations transplantations of vessels and organs MD PVC Rat comes in a carrying case together with a video user guide several spare parts and the computer simulation program Remote an interactive oatient monitoring system which can be used in combination with the MD PVC Rat The software runs on a computer system with Windows 95 or higher operating system One can train the skills needed for patient monitoring during several micro surgical techniques During surgery anesthesia can be administered the animals temperature and breathing can be observed and controlled When the exercise is finished the software generates a full report showing every event and status MODEL DESCRIPTION MD PVC Model MD PVC Parts Atlas of a Mouse Histology An essential reference source for anyone involved in experimental biology This disk is an informative reference guide showing all the organs of
65. 3 x 0 014 with stylette and 23ga thin wall needle MTV 3 10cm of 28ga 0 014 x 0 007 connected to 31 5 of 0 033 x 0 014 and 23G thin wall needle no stylette More options available online at braintreesci com MTV 25 Micro Cannula System The Micro Cannula System provides quick and convenient access to an artery or vein in small animals such as mice and rats The tapered design of the PFA tubing provides strength while maintaining a very small distal tip of 0 016 OD x 0 008 ID The sharpened stylette and beveled tip provides easy insertion into any vessel Total length is approximately 10cm not including the stylette MODEL DESCRIPTION MC 28 Micro Cannula System 6 BRAINTREE SCIENTIFIC 781 348 0768 Urinary Systems URI bladder catheter systems were developed to maintain patency regardless of its position within the bladder Its specific oval design covers a significant volume inside the bladder and its elasticity allows it to collapse when the bladder is void thereby decreasing discomfort and trauma to the mucosa wall DESCRIPTION URI 1 small Bladder Catheter rodents small animals 125ga 1kg Catheter Size 3 French e Catheter material Silicone URI 2 Medium Bladder Catheter animals 1kg 5kg Catheter Size 5 French e Catheter material silicone Bile Duct Catheter For bile duct collection in rats with a fine diameter tip MRE 025 MODEL DESCRIPTION R BDC Bile Duct Catheter Duodena
66. 40 AM Page 48 a Mixers and Shakers Multi Therm VorTemp 56 Incubator Shaker pi Cool Heat Shake gt Temperature control from 0 to 100 C gt Exchangeable blocks for tube sizes 0 2 to 50ml gt Precision contoured wells for uniform thermal transfer gt Two models heat cool or heat only Designed for simultaneous heating and mixing of small samples features Technical Data interchangeable platforms for Temperature range HC Ambient 20 to 100 C microtubes and microplates both platforms Temperature range H Ambient 5 to 100 C included Temperature is adjustable over a broad range making the Heating ramp rate 5 0 C min unit useful for a variety of applications mechanical convection provides Cooling ramp rate 2 5 C min HC only a uniform and stable environment within chamber May also be used in cold Temperature accuracy 1 0 C room for subambient applications Shaking speed as well as acceleration Speed range 200 to 1500 rpm or off rates are adjustable Acceleration can be set to three different levels to Motion orbit Horizontally circular 2mm protect delicate samples Self diagnostic software continuously monitors unit Capacity Per selected block for proper temperature and shaking speed alerting user to any errors Dimensions 8 25 x 11 5 x 8 25 21cm x 29cm x 21cm Heating and shaking are controlled by feedback loops which precisely Multi Therm shaker is a temperature cont
67. 5 packs of 10 each SP0444 Round Cap Piercable DMSO Resistant rigid 5 packs of 10 each SP0347 Round Cap Autoclavable non DMSO Resistant 5 packs of 10 each non piercable Square gt Flexible mat designed to seal square well storage plates gt Pierceable version is solvent Oem resistant including DMSO ee MODEL DESCRIPTION SP0081 Square Cap Piercable DMSO Resistant 50 Mats SP0093 Square Cap Autoclavable 50 Mats a Adhesive PCR Foil PCR Storage gt Designed for PCR Can be pierced with a pipette tip with no adhesive build up on tip gt Recommended for use in conjunction with a cycler that has a screw down or clip down lid gt Peelable Pierceable Temperature range 70 C to 150 C MODEL PACKAGE TYPE SP0028 100 Sheets QTY UNIT 100 Adhesive PCR Film PCR Storage gt Designed for PCR Optically clear for sample visibility gt Recommended for use in conjunction ce ae 2 x ey Ors Se ee with a cycler that has a screw cdown Sete Te as we or clip down lid Why SS r E gt Peelable temperature range 20 C TELL piee J to 120 C MODEL PACKAGE TYPE QTY UNIT SP0027 100 Sheets 100 Uitra Clear Adhesive QPCR Film gt Designed for QPCR and other fluorescence applications RD gt Recommended for use in conjunction with a cycler that has a screw down l B or clip down lid gt Peelable temperature range 40 C to 120 C MODEL PACKAGE TYPE QTY UNIT SP0605 100
68. 50 Dedicated platform with 8 x 250ml Erlenmeyer flask damps attached H1000 P 125 Dedicated platform with 12 x 125ml Erlenmeyer flask clamps attached H1000 P MP Dedicated platform 4 x microplates standard or deepwell H1000 P SP spring rack platform for uncommon vessels and containers a Mixers and Shakers Enduro MiniMix Perfect for western blots Labnet s Enduro MiniMix combines motions of an orbital shaker and a rocker to produce three dimensional action The benefit of this type of motion is that it is both gentle and thorough The pitch and speed of the Enduro MiniMix are fixed to provide the optimal conditions for processing western blots and staining gels Tilt angle is large enough to provide thorough distribution of solutions yet small enough to keep the center of blot from drying out Minimal amounts of solution can be used conserving valuable probes and antibodies Mixer is supplied with a non slip rubber mat to help keep boxes in place on platform Housing and platform are easy to clean and decontaminate when needed For temperature controlled incubations the Enduro MiniMix may be p used in a cold room or an incubator Lightweight and compact and easily moved where needed Available in two sizes Small boxes have a capacity for 3 5ml of solution and are perfect for mini protein gels such as those used in the Enduro Mini PAGE System Large boxes will hold 6 10ml and are sized for larger mini protein gels
69. 8 L x 9 W Ultra Safe Thermo Regulation gt Will not over heat or burn animal gt No electricity used MODEL DESCRIPTION TCRP Thermo Control Recovery Pad shoe box cage not included SpaceGels spaceGels heating pads are formed by sealing a super saturated liquid solution in a pouch similar to an IV bag The pouch also contains a small metal activator disc When the disc is flexed the solution freezes and solidifies giving off heat in the process The heating pads reach a maximum temperature of about 130 F Because the heating process is physical not chemical the pouches can be reused several hundred times To reset a SoaceGel heating pad simply heat through steaming or boiling until all crystals have dissolved Once cooled it can be reactivated and used again spaceGels have many uses A SpaceGel can be placed between a cage containing a recovering animal and the table to provide heat during recovery small animals can be placed on the heating pads with some sort of barrier towel cloth etc A SpaceGel can be wrapped and placed on a part of the animal to be warmed or on the arteries if warming a large animal oO MODEL DESCRIPTION SPGL S Space Gel Pad 4 x 6 SPGL L Space Gel Pad 5 5 x 10 Gel Pad Reactivation Unit Small size is ideal for lab bench 12 Lx 10 Wx 8 5 H a e Easily reactivate four gel pads in a single run e Place in chamber start remove pads after 15 n A minutes Safe a
70. 8 OD distal portion 0 005 ID each lumen polyurethane catheter a bonded connection assembly flared to accept a 32ga needle a 0 003 diameter Teflon coated stainless steel stylet to facilitate placement Individually packaged Supplied non sterile DL 5F Polyurethane central vein catheters Double lumen CVC s allows multiple drugs to be administered through the same catheter Can be utilized to infuse drugs antibiotics or blood sampling Supplied non sterile MODEL DESCRIPTION DLR 4 Double Lumen Renathane Catheter 4 French diameter approx 0 050 1 25mm OD kit of 3 DL AS 040 MRE 040 OD SUBL 160 CR DL28 11 7cm 28ga 0 007 ID CR DL32 11 7cm 32ga 0 005 ID DL 5F oF x 8cm Double Lumen Catheter with Soft Tip Skin Buttons Rodent skin button with luer attachment With all the features as the standard skin button the skin button with a luer attachment allows for an external access port to the animals catheter The animal s catheter is passed through the skin button and sat attached to a luer fitting The luer fitting allows for easy sampling or dosing via the animals catheter This product comes as two pieces and is easily assembled during surgery MODEL DESCRIPTION SBD 02 Skin Buttons a Catheters 27 Y Connector Catheter Sth _ wA S j Y Connector Catheter is designed to be used with a syringe pump for infusion and withdrawal of fluids Primarily used to adapt two osmotic pu
71. Block 54 x 0 5ml H5000 CMB Block combination 15 x 0 5ml and 20 x 1 5ml H5000 15 Block 35 x 1 5m H5000 20 Block 35 x 2ml H5000 12 Block 24 x 12mm 200 to 1200 rpm Ambient 10 to 100 C vi H5000 150 Block 12 x 15ml 200 to 750 rpm Ambient 10 to 100 C Other models and capacities available online or by email Please H5000 500 Block 6 x 50ml 200 to 750 rpm Ambient 10 to 100 C visit www braintreesci com or email info braintreesci com for Note The larger mass of this block results in a reduced speed and temperature range details and pricing 48 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page 49 Incu Shaker Mini gt Exceptional temperature uniformity gt Extremely compact just 11 wide gt Exchange flask clamps in one second with the MAGIC CLAMP magnetic system Incu Shaker Mini is the most compact shaking incubator in its class Despite the remarkably small footprint a large 11 5 x 9 5 work space accepts several platforms for use with a variety of flasks tubes and other common vessels Standard platform included features a non slip rubber coated surface ideal for tissue culture flasks petri dishes and staining trays Convenient MAGIC CLAMP platform is also available for use with Erlenmeyer flasks and test tube racks Unique magnetic attachment method is the easiest way to instantly change between flask clamps of different si
72. Boxes are acrylic and feature a hinged lid with a positive catch supplied in packages of 10 gt Designed for processing blots and staining gels gt Optimal fixed speed and tilt gt Three dimensional motion gt Enduro Blot boxes are perfect for protein gels Specifications Speed 115V 230V 18 rom 20 rom Motion 3D nutating Angle 5 Ambient operating range 4 65 C Dimensions 8 x 7 x 4 5 20 3cm x 17 8cm x 10 5cm MODEL DESCRIPTION s0600 Enduro MiniMix 3D Shaker with 20 x 16 5cm tray and non slip rubber mat E2110 BBS Enduro Blot box 9 1 x 6 6cm 3 5ml capacity 10 pack E2110 BBL Enduro Blot box 11 7 x 8 9cm 6 10ml capacity 10 pack Visit us online at www braintreesci com 49 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page 50 Lab Equipment MultiGene Mini Compact and lightweight thermal cycler is packed with features typically found on larger thermal cyclers Accuracy and uniformity combine with fast ramping rates to provide quality results An algorithm calculates sample temperature based on volume to control heating and cooling of the block Samples reach programmed temperatures quickly without any overshoot or lagging Powerful Peltier units provide ramping rates as fast as 5 C second Programming is simple and intuitive Control pad combines function keys a key pad and arrow keys for easy navigation and entering of parameters Large display is easy to read In additio
73. D 1200 Ideal Micro Drill less power and provide longer battery life a Lab Equipment 271 NSET Non Surgical Embryo Transfer Device Paralechs Corporation has revolutionized embryo transfer in mice with the NSET non surgical embryo transfe device for mice NSET allows non surgical embryo transfer for production of research transgenic or knock out mice NSET is a major refinement of murine embryo transfer as it eliminates pain and stress of surgery and anesthesia MODEL DESCRIPTION NSET Non Surgical Embryo Transfer Device 277 Liquid Nitrogen Cooled Mini Mortar and Pestle Set Freeze and process tiny tissue samples within a microcentrifuge tube Stainless steel mortar has a welded fixture to hold a 1 5m microcentrifuge tube Mortar is suspended above a stainless steel cavity which holds liquid nitrogen and is nested in a heavily insulated blue polyethylene housing gt Permits grinding of smaller amounts of tissue right in a 1 5ml microcentrifuge tube resulting in reduced sample loss and collection time gt Prevents tube from cracking by eliminating direct contact with liquid nitrogen gt Includes 5 long stainless steel pestle with 4 W 10 2cm x 75 D 1 9cm polyethylene handle gt Housing overall dimensions 6 5 D 16 5cm x 4 5 H 11 4cm suction feet keep it stable on the workbench gt Removable insulated mortar handle 4 L 10 2cm MODEL DESCRIPTION 372600100 Liquid Nitrogen Coo
74. D x 0 010 ID 40cm long with an attached 27ga blunted luer hub MODEL DESCRIPTION MIC Molecular Imaging Catheter Restrained Tail Vein Infusion Model Most researchers use butterfly needles to administer fluids via the tail vein Allows access for both timed injections and repeated bolus administration The MTV 1 system incorporates a small catheter that is easily inserted into the tail vein and will remain insitu in a restrained mouse for as long as restraint is feasible Due to the flexibility and size of the catheter trauma to the tail vein is minimized allowing for long term and repeated bolus dosing By avoiding the damage associated with indwelling needles there is an increased chance that the tail vein will remain viable for the duration of the study MTV 2 MTV 2S MTV 3 catheters are used for researchers that use small bore MRI machines or that need extra length for long bore magnets MTV 9 includes stylet splittable needle and injection cap gt Eliminates the need for an assistant gt Reduces setup and procedure time gt Provides superior control gt Improves visualization MODEL DESCRIPTION MTV 1 Restrained Tail Vein Infusion Catheter 10cm of 28ga 0 014 x 0 007 connected to 7 of 0 033 x 0 014 with stylette and 23ga thin wall needle MTV 2 10cm of 28ga 0 014 x 0 007 connected to 20 of 0 033 x 0 014 and 23ga thin wall needle no stylette 10cm of 28ga 0 014 x 0 007 connected to 20 of 0 03
75. DESCRIPTION Mouse Restrainer for mice 20 60g 500M Smoked Canvas 500M C Clear Canvas Rat Restrainer for rats up to 350g 700R Smoked Canvas 700R C Clear Canvas Rat Restrainer with watering system 800R Smoked Canvas Clear Canvas 800R C Rat model also features unique spiral grip and optional watering system Visit us online at www braintreesci com 15 7231BRASCI_NOPRICE 12 13 12 11 35 AM Page 16 Restrainers Dorsal Access Mouse Restrainer Accurate safe and fast way to give injections The dorsal skin of the mouse is easily accessed through the top circular opening enabling the user to perform subcutaneous injections without risk of being bitten and less likelihood of user sticking own finger gt Easy entry draw mouse tail first or lead head first through the wide entry funnel into the back of the tube and then position stop gate in choice of two slots gt With tail first entry tail is exposed at rear of tube allowing easy access for tattooing and tail bleeds gt Overall dimensions 7 4cm L x 10cm W x 6 7cm H 6 8 L x 3 9 W x 2 6 H gt For mice 18 359 gt Made from crystal clear durable and chemical resistant TPX gt Unlike acrylic can be repeatedly disinfected with EtOH and is autoclave safe MODEL DESCRIPTION DA MOUS Dorsal Access Mouse Restrainer Tailveiner Tail vein injection made easier The Tailveiner is the first _ i easy to use mouse and rat rest
76. DIA N 001 24ga 1 Straight 1 25mm N 002 22ga 1 Straight 1 25mm N 003 20ga 3 Straight 2 20mm N 004 18ga 3 Straight 2 25MM N 005 20ga 3 Curved 2 25MmM N 006 18ga 3 Curved 2 25MmM N 007 16ga 3 Curved 3 00mm N 008 18ga 1 Straight 2 25MmM N 009 16ga 4 Curved 3 00mm N 010 20ga 1 5 Curved 2 25MM N 020 22ga 1 5 Straight 1 25mm Items shipped by the dozen or 4 per pack Sterile Flexible Plastic PTFE Disposable Feeding Needles Animal feeding needles AFN allow user to precisely dispense liquid to animal while minimizing the chances of esophogial piercing Sterile non toxic and non pyrogenic available in a variety of gauges and lengths 100 sterile needles per box i MODEL GAUGE LENGTH BALL DIA QTY DT 9928 18ga 1 5 2mm 100 DT 9925 15ga 3 07 2 8mm 100 DT 9920 20ga Lo 1 9mm 100 Additional sizes coming soon wW Flexible Plastic PTFE Disposable Feeding Needles with Bite Protectors Flexible plastic PTFE tube is covered at hub end with 304 stainless steel tubing protecting tubing from damage due to biting during use Plastic PTFE tube is softer than other tubing types very flexible and translucent for easy confirmation of reagent delivery Plastic luer hubs and soft silicone tips non toxic and non pyrogenic Packaged 5 needles per sterile peel pouch 20 pouches per box MODEL GAUGE LENGTH BALL DIA QTY BG 9928 18ga 1 5 2mm 100 BG 9923 18ga 2 2mm 100 BG 9924 18ga 3 2mm 100 BG 9926 17ga 39 2 4
77. ESCRIPTION PP 23 0 025 plug ML 2 Miniature Manifold 2 ports PP 22 0 028 plug ML 4 Miniature Manifold 4 ports PP 21 0 032 plug ML 6 Miniature Manifold 6 ports PP 20 0 036 plug ML 8 Miniature Manifold 8 ports PP 19 0 042 plug MM 2 Miniature Manifold 2 ports MM 4 Miniature Manifold 4 ports MM 6 Miniature Manifold 6 ports Stainless Steel Connectors Stainless steel tubing connectors 0 5 MODEL DIMENSIONS C 30 30 gauge C 28 28 gauge C 27 2 gauge C 23 23 gauge C 22 22 gauge C 21 21 gauge C 20 20 gauge C 19 19 gauge gaug YEARS 1980 2012 dagl on Braintree Scientific Visit us online at www braintreesci com 3 7231BRASCI_NOPRICE 12 13 12 11 32 AM Page 4 Catheters Vascular Catheters for Rats and Mice Vascular catheters have stood the test of time because they are affordable and they work These catheters modified from the original design of Tinsley 1983 are fabricated with Braintree Scientific s medical grade polyethylene PE tubing and silicone rubber tubing Renasil Sealed with a stainless Steel plug when filled with a viscous catheter lock solution they maintain a very high rate of patency for several weeks Both thoracic and femoral models feature gt Externalized polyethylene PE tubing catheter port gt Flared for easy access with a blunted 23 ga hypodermic needle for sampling or infusion gt Port is sealed with 0 025 diameter stainless steel plug when not in use gt
78. Grade 5 127mm Curved delicate narrow tips FC1008 Premium Grade 5 127mm Iris Tissue Forceps sharp 1 x 2 interlocking teeth for secure grip with minimal tissue compression MODEL DESCRIPTION FC0037 Straight 1 x 2 teeth 4 101 6mm FC0038 Full curved 1 x 2 teeth 4 101 6mm Adson Forceps Extra broad ribbed grip for delicate precision dissection Available with serrated or toothed tips MODEL DESCRIPTION Standard Grade FCO27 Dressing serrated 4 75 120 7mm FC028 Tissue 1 x 2 teeth 4 75 120 7mm Premium Grade FC127 Dressing serrated 4 75 120 7mm FC128 Tissue 1 x 2 teeth 4 75 120 7mm Delicate Specialty Dissection Forceps MODEL DESCRIPTION Delicate Tissue Forceps FC032 serrated 5 127mm FC033 Tissue 1 x 2 teeth 5 127mm FCO41 Fine Point 4 5 127mm Extensive selection of instruments available Please email info braintreesci com for details and pricing Instruments Standard Pattern Tissue Forceps secure ribbed grip MODEL DESCRIPTION Standard Pattern Serrated Handles 1 x 2 Teeth FCO09 Standard Grade 4 5 114 3mm FC109 Premium 4 5 114 3mm FC110 Premium 5 127mm Dumont Forceps MODEL DESCRIPTION FC 5005 109mm Inox 45 angle tip 0 05 x 0 01mm FC 5058 109mm Dumoxel 45 angle tip 0 10 x 0 06mm FC 5043 110mm Inox straight 11cm Micro Instruments Micro Scissors Very delicate scissors for precision dissection Excellent for small animal dissect
79. ION TCAT 2AC Controls AC only powered heating or cooling devices such as a heat lamp TCAT 2LV Provides low voltage DC output for electrically sensitive applications where AC frequencies might interfere with other monitoring devices Includes built in DC power TCAT 2DF Includes both AC outlet for controlling primarily resistance loads such as heat lamps AC powered warming blankets and a low voltage low noise DC output for heating pads Allows user to control a variety of different loads All TCAT 2 versions may be used with any of our extensive line of accurate Type T thermo couple probes which act as the temperature feedback sensor Most commonly used are the RET series of animal rectal probes but the IT series of implantable flexible probes and MT series of needle probes may also be used depending upon the specific application All instruments are designed to operate on a 110V or 230V AC supply Heat Lamp Optional infrared heat lamp is table mounted with a standard u screw clamp that expands to fit tables up to 2 25 deep An 18 adjustable swing arm provides easy adjustment of radiant heat to specimen The lamp is supplied with a 250w infrared heat lamp bulb and a built in reflector A chrome bulb guard is also provided and easily snaps onto the lamp housing after the bulb is installed Fits standard 110v AC socket Power 10 watts MODEL DESCRIPTION HL 1 Heat Lamp HP Heat Plate Other models available online Please vis
80. Kevlar Deerskin Handling Gloves Large KVL LTH X Kevlar Deerskin Handling Gloves Extra Large Classic Guillotine One stroke instantly decapitates rats mice and other small animals Blades are hand honed stainless steel and form an opening 1 75 along each side All surfaces are accessible to allow washing without disassembly Base can be mounted to a bench or board and the handle can be easily reversed for operation with either hand We recommend the use of DecapiCones to ensure additional safety when dispatching rats or mice MODEL DESCRIPTION RG 100 Classic Guillotine 27 Nemi Guillotine gt Easy blade replacement gt Mounting plates for all models optional gt Manufactured using only the finest materials gt Built to stay in your lab gt Extremely cost effective MODEL DESCRIPTION NS 802 Nemi Guillotine Rats and Mice 2 opening along each side NS 804 Nemi Guillotine Rats and Mice 4 opening along each side NS 806 Nemi Guillotine Larger subjects 6 opening along each side Replacement blades available online Gloves Armour Touch Metal Mesh Gloves Protects hands from teeth and claws when handling small animals YES You have seen this material used for anti shark suits Braintree Scientific s metal mesh gloves provide security and a sure grip This is the original and only metal mesh glove for rodent handling Experience shows animals are easier to
81. ON CL150 0 Without Light Guide CL150 1 With Single Light Guide a 2 CL1502 With Bifurcated Light Guide Visit our website at www braintreesci com CL150 3 With Ringlight Visit us online at www braintreesci com 69 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 70 a Anesthesia Line Small Animal Anesthesia Systems Classic Small Animal System that evolve with your needs Safe easy to use anesthesia systems for small animals E Z Anesthesia customizes systems to integrate seamlessly with your existing equipment These systems can be customized to satisfy your current needs while providing the flexibility to expand and meet future requirements An innovative solution that offers the ultimate in user friendly simple operation with a level of precise automation that minimizes operator error Each system incorporates a breathing valve that controls gas flow to the nosecone and protects both animals and technicians from overexposure Classic Starter System to gas Switching trom working with mice to rats Is as easy as changing Includes core EZ Anesthesia components without heating system Heating a NOSecone components may be added to the system as needed The E Z system is expandable to accommodate up to four breathers The Featuring the Microflex Breather system is adaptable to a wide range of procedures from STEREOTAXIC MRI X Ray PET simply by interchanging a breather Low profile breather is suitable for w
82. Order S for a sagittal style and C for a coronal style MODEL SPECIFICATIONS CAVITY DIMENSIONS BS 2000C Adult Mouse 30gm 13 9 x 9 9 x 7 5mm BS 20008 Adult Mouse 30gm 13 9 x 9 9 x 7 5mm BS 3000C Rat 125 185gm 20 x 13x 6 8mm BS 3000S Rat 125 185gm 20 x 13x 6 8mm BS 4000C Rat 200 400gm 25 5 x 16x 11 2mm BS 40008 Rat 200 400gm 29 5 Xx 16x 11 2mm 78 BRAINTREE SCIENTIFIC 781 348 0768 a Adjustable All Purpose Acrylic Channel or Cavity Tissue Brain Matrice Acrylic all purpose tissue brain matrice has an adjustable cutting width and can be used to generate 1mm incremental thick sections in all types of tissues The adjustable length of cutting surface is from 1mm to 25mm The flexibility of these acrylic matrices makes it ideal for many different tissue slicing functions Order S for a sagittal style and C for a coronal style MODEL DESCRIPTION TM S 9 Straight Adjustable Tissue Cutting Channel cutting depth 10mm TM S 12 Straight Adjustable Tissue Cutting Channel cutting depth 12mm TM C 9 Straight Adjustable Tissue Cutting Channel cutting depth 10mm TM C 12 Straight Adjustable Tissue Cutting Channel cutting depth 12mm Sterile Disposable Biopsy Punch with Plunger j u i SPECIFICATIONS 1mm diameter 25 box 1 5mm diameter 25 box 2mm diameter 25 box MODEL MTP 33 31A MITP 33 31B MTP 33 31C Tissue Slicer Blades MODEL SPECIFICATIONS BS BLADES 25 count Steel Blades g YEARS 1980 201
83. Platform BioLite Stand Simple durable stand is easy to clean store and is portable Constructed from durable polycarbonate this platform provides the perfect stage for intubating mice and rats of all sizes The animal is suspended from the incisor wire on the angled side of the stand Three mounting positions are available to customize the placement of the animal on the stand in order to meet the user s needs Two sets of posts are provided with each stand Each post has three positions for the height adjustment to optimally accommodate user and animal stand is constructed from a single piece of polycarbonate plastic with a seamless design The top of the stand provides a hand rest for stabilization during intubation that is designed to support significant weight Compact seamless design and its construction make this stand easy to clean Will not crack with the use of harsh cleaning agents as with similar stands constructed from acrylic MODEL DESCRIPTION RIS 100 For Mice RIS 200 For Rats Visit us online at www braintreesci com 13 7231BRASCI_NOPRICE 12 13 12 11 35 AM Page 14 P Surgical Tables and Boards Deltaphase Operating Board Thermo Controlled Surgery Platform Easily maintain animal body temperature during surgery This compact operating board takes advantage of the Deltaphase principle to maintain animal body temperature during surgical or experimental procedures An 8 5 square stain
84. RICE 12 13 12 11 36 AM Page 21 W Mouse Irradiation Chamber gt 1 8 3 2mm clear acrylic gt Flip top lid for easy loading and unloading gt Perforated top allows air to circulate throughout unit gt Top incorporates a slot for filter material to improve contamination control gt Non skid feet prevent unit from slipping and sliding gt 6 Dia x 2 H 15 24cm Dia x 5 08cm H MODEL DESCRIPTION AK MIC Mouse Irradiation Chamber Modified Pie Cage to accept aerosol delivery Aerosol enters the PIE via tubing attached to the central core Core is open on the top and solid on the bottom PIE rotates so mice can be placed in individual sections a Aerosol is distributed to each PIE section via five 3mm holes Aerosol exits each PIE section through one 3mm hole in the center of the outer edge MODEL DESCRIPTION MPC AERO Mouse Aerosol Cage RPC 1 AERO small Rat Aerosol Cage 41cm dia 6 75cm height RPC 2 AERO Large Rat Aerosol Cage 46cm dia 8cm height Rat aerosol cages available call for details and pricing Rat and Mouse Pie Cages Cages are easy to clean and to use Circular cages hold up to 11 rodents for whole body irradiation Notched removable lid can be dialed to any of the ventilated pie shaped chambers Also use for temporary transport or storage a Irradiation Rad Disk and Rad Disk Mini Polycarbonate Rodent Microisolation Irradiator Cages New for 2013 Imbedded Jump G
85. Sensor conscious mice and young rats M CollarClip Sensor conscious mice and young rats XS ThroatClip Sensor anesthetized mice and young rats S ThroatClip Sensor anesthetized mice and young rats M ThroatClip Sensor anesthetized mice and young rats Mouse Thigh Sensor anesthetized mice and young rats L CollarClip Sensor conscious rats XL CollarClip Sensor conscious rats 2XL CollarClip Sensor conscious rats L ThroatClip Sensor anesthetized rats XL ThroatClip Sensor anesthetized rats 2XL ThroatClip Sensor anesthetized rats Rat Foot Sensor anesthetized rats MouseOx Plus System available call for information 66 BRAINTREE SCIENTIFIC 781 348 0768 OxyDial 0 100 Blender HypoxyDial 0 21 Blender Allows user to quickly and easily dial oxygen fraction FlOz and 02 N2 gas mixtures Using universal fittings the system connects to centralized supplies bottles or wall outlets of oxygen and nitrogen User simply turns a dial to set oxygen percentage and can adjust outlet flow rate to obtain a constant stream of gas at desired FlQz and flow rate System is purely mechanical and uses no electrical power Includes all hoses and fittings to connect from bottled gas source to blender MODEL DESCRIPTION SLS 000500 OxyDial with pressure hoses and regulators SLS 000503 Hypoxy Dial with pressure hoses and regulators Pulsar MRI Compatible Sensor Pulsar MRI Sensor plugs directly into
86. Sheets 100 Adhesive Storage Film gt Economical plate seal designed for short term storage and benchtop use gt Peelable temperature range 40 C to 80 C MODEL PACKAGE TYPE QTY UNIT SP0443 100 Sheets 100 Visit us online at www braintreesci com 37 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 38 PCR Plates Tubes and Seals 0 2mli PCR Tubes gt Uniform thin walls gt Compatible with standard 0 2ml thermal cycler blocks gt 0 25mi maximum volume gt Flat caps are frosted MODEL DESCRIPTION QTY BX SP0019 0 2ml PCR Tube domed cap 2 bags of 500 SP0018 0 2ml PCR Tube flat cap 2 bags of 500 0 5mi PCR Tubes gt Uniform thin walls gt Compatible with standard 0 5ml thermal cycler blocks gt 0 6m maximum volume gt Both domed and flat caps are frosted MODEL DESCRIPTION QTY BX SP0022 0 5ml PCR Tube domed cap 4 bags of 250 SP0021 0 5ml PCR Tube flat cap 4 bags of 250 PCR Strip Tubes YUU IVY gt Thin wall design for rapid heat transfer gt Compatible with standard 0 2ml thermal cycler blocks gt Can be cut into individual tubes MODEL DESCRIPTION QTY SP0023 0 2ml PCR strip tubes strips of 8 10 packs of 12 strips SP0020 0 2m PCR strip tubes with bag of 250 each strip tubes domed caps strips of 8 Low Profile PCR Strip Tubes and strip caps T7 gt 150uL maximum volume gt Strip has A H labeled end tabs gt Designed to reduce dead space and pr
87. TION a Non Skirted Flexible SP0084 Box of 100 bulk packed 7 gt Original PCR plate design s 0 8ml Round Well Conical Bottom gt Flexible deck allows plate to be easily cut CES E gt Conical bottom aids in complete into strips or other desired sizes GTT sample retrieval a gt Sealing options Heat sealing adhesive Ger gt Sealing options Heat sealing adhesive Ty Pa SSPE 1 sealing PCR cap strips sealing and mat caps i i n MODEL DESCRIPTION gt SBS footprint stackable robot compatible 24 SP0016 Box with 5 packs of 5 each MODEL DESCRIPTION Non Skirted Ri gi d SP0073 Box of 50 individually wrapped 7 gt Rigid plate deck provides firm handling Je eae Het SOU NG one noon gt Sealing options Heat sealing adhesive ee gt U bottom aids in resuspension makes plate sealing PCR cap strips Tos suitable for bacterial growth cultures MODEL DESCRIPTION gt Sealing options Heat sealing adhesive sealing SP0074 Box with 5 packs of 5 each and mat ey Semi Skirted Break gt SBS footprint stackable robot compatible PESKIG TETAS MODEL DESCRIPTION d Aahe T ae ites SP0080 Box of 50 individually wrapped to be cut into 24 an well sections EET srg gt Versatile semi skirted plate with broad EEES E A 2 2ml Square Well U Bottom range thermal cycler compatibility Goes gt U bottom aids in resuspension makes plate gt Sealing Options Heat sealing adhesive sealing suitable for bacterial growth cultures PCR cap strips
88. TION CAPACITY SAMPLE SIZE BBX 24B Bullet Blender STORM 1 24 1 5 2ml 0 01g 0 3g BBY 24M Bullet Blender Blue 5 1 12 oml screw cap tubes 0 10g 19 BB50 DX Bullet Blender 50 DX 1 8 50ml tubes 0 10g 3g Screw cap tubes also available Shop online at www braintreesci com CIN ae 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page 55 Infrared Microsterilizer f BactiZapper has an asbestos free core Bacti element that uses infrared heating to produce 815 C 1500 F It completely sterilizes micro organisms in 5 7 seconds BactiZapper uses well proven technology to provide instant sterilization of platinum inoculating loops needles glass tube pipette mouths and various metal and borosilicate glass instruments Ceramic heating element is safely enclosed in a perforated stainless steel guard chamber protecting users from accidental contact with extreme temperatures of the core area It is extremely compact convenient and can be used in anaerobic and aerobic chambers gt Complete infrared sterilization in 5 7 seconds gt Safe convenient and no spatter gt Ideal for platinum loops needles and tube mouths Specifications Max temperature 815 C 1500 F Sterilization 5 7 secs Chamber diameter 0 55 14mm Chamber length 3 94 100mm pe External dimensions 4 x 6 x 6 5 MODEL DESCRIPTION B1000 BactiZapper Infrared Microsterilizer Germinator 500 Dry sterilize surgical instruments in secon
89. TY MS2 Innocage Static Mouse top and bottom 05 100 MS2 C8 Innocage Static Mouse pre bedded 0 125 Corn Cob set 100 MS2 AD Innocage Static Mouse pre bedded Alpha Dri set 100 MS4 Innocage Transport Mouse top and bottom 100 MS4 C8 Innocage Transport Mouse pre bedded 0 125 Corn Cob set 100 MS4 AD Innocage Transport Mouse pre bedded Alpha Dri set 100 M BTM Innocage Mouse bottom only 00 0 0 eee 100 M BTM C8 Innocage Mouse bottom only pre bedded 0 125 Corn Cob 100 M BTM AD Innocage Mouse bottom only pre bedded Alpha Dri 100 M FEED Mouse Feeder extended use standard 6 100 M FEED SS Mouse Feeder extended use stainless steel 100 M FEED P Mouse Feeder extended use plastic 004 100 M WB 300 Aquavive Mouse Water Bottle empty 00 100 CRD HLD U Card Holder 00 0 ccc cette ens 100 TN aE 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 25 Deltaphase Isothermal Pad Maintains animals or cultures at 37 C for hours Ideal for NMR Based on fundamental thermodynamics completely safe even with flammable gases Uses no electricity wires or control box Reusable Why you need them Normal biochemical functions are based on the temperature of 37 C In conscious animals core temperature is maintained During anesthesia body ennea falls Normal chemistry is disturbed surgica
90. W Mouse Pie Wedge single slice with sliding cover RD P R Bat irradiator C ith Divid ee MP FLT Replacement Filter z k s i ee EE e 10 75 dia x 4 H RPC 1 Small Rat Pie Cage ar nae RD FLT M Mouse Irradiator Cage Replacement Filter SES ERNE ase me IRD FLT R Rat Irradiator Cage Replacement Filter Individual chambers 10cm base 18cm length gene RPC 2 Large Rat Pie Cage Unit dimensions 46cm dia 8cm height Individual chambers 11 5cm base 20cm length Visit us online at www braintreesci com 21 CT L 7231BRASCI_NOPRICE 12 13 12 11 36 AM Page 22 Irradiation Mouse Fixtures and Shields Partial Body Irradiation Fixtures and Shields standard holding fixtures and corresponding lead shield for mice Can be purchased separately or as a set Fixture Shield Intensive Care Units Canister Humidifier Allows approximately 2 3 hours of oxygen therapy and should be filled with distilled water Includes gt Plastic collar gt White nipple connector with cap gt 7 crush proof Oz tubing to canister gt Chrome DISS at top of canister gt 7 crush proof Oz tubing from canister to O2 source MODEL DESCRIPTION HUM CAN Caniser Humidifier Modified Mouse Pie Cage sold separately Canister Nebulizer Canister nebulizer with a dial on the top Allows approximately 2 hours of therapy Nebulization does not require oxygen compressed air is sufficient Use of distilled water is su
91. al speed control up to 300 rom The Orbi ShakerJR is a space saving shaker complete with a 9 5 x 8 non slip rubber coated platform that is ideal for tissue culture flasks petri dishes and staining trays Additional platforms are also available for the Orbi Shaker JR including the convenient MAGic Clamp platform for use with Erlenmeyer flasks and test tube racks The unique magnetic attachment method is the easiest way to instantly change between flask clamps of different sizes Technical Data Speed range 50 to 300 rom Speed increment 10 rom Orbit 19mm 3 4 Maximum capacity 4 x 1L or 4 kg Standard platform dimensions 9 5 x 8 24cm x 20cm Dimensions 11 x 10 7 x 5 28cm x 27cm x 13cm Operating Temperature 4 to 650 C MODEL DESCRIPTION BT300 Orbi Shaker JR H1000 MR MAGic Clamp universal platform 9 5x8 H1000 MR 50 Clamp for MAGic Clamp platform 50ml max 20 H1000 MR 125 Clamp for MAGic Clamp platform 125ml max 12 H1000 MR 250 Clamp for MAGic Clamp platform 250ml max 8 H1000 MR 500 Clamp for MAGic Clamp platform 500ml max 6 H1000 MR 1000 Clamp for MAGic Clamp platform 1000m max 4 H1000 MR 1550 Tube rack for MAGic Clamp platform 12x50 and 21x15ml conical tubes max 2 Rolling bar platform for uncommon vessels BT300 RP Visit our website at www braintreesci com Visit us online at www braintreesci com 47 7231BRASCI_NOPRICE 12 13 12 11
92. an affordable means to administer humidity oxygen medicated nebulization treatments and or treat respiratory stress in the care of animals and birds Unit is easy to assemble clean and operate and is recommended for in home care of chronic conditions that require respiratory therapy All unheated therapy units include Swing away dual venting and handport covers to discourage buildup of heat humidity or CO2 and provide easy access to animal patient Patients may be viewed through the windows and door grill which has a removable clear plastic door Specifications Small 27 75 L x 19 5 W x 20 25 H Medium 32 25 L x 22 25 W x 23 25 H Large 36 5 L x 25 5 W x 26 75 H Accessories include canister nebulizer medication nebulizer humidifier temperature humidity gauge O2 hose fittings hose connectors tubing and removable floor matting MODEL DESCRIPTION SIZE NTC 2 Unheated Nebulizer O2 Therapy Cage with accessories Small NTC 3 Unheated Nebulizer O2 Therapy Cage with accessories Medium NTC 4 Unheated Nebulizer O2 Therapy Cage with accessories Large Visit us online at www braintreesci com 23 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 24 Transport Cages Emergency preparedness with disposable cages All Innovive cages are BPA FREE Both equipment failure and a natural disaster can be dealt with efficiently and safely using the Innovive disposable irradiated Innocage Static rodent
93. and user s manual are included for collection and processing of photos gt Resolution 640 x 480 pixels gt Magnification 10 200x continuous gt Sensor 1 4 Color CMOS gt Video frame rate up to 30 frame per second gt Illumination built in 8 white LEDs gt CD Content DinoCapture application software users manual gt Automatic or manual color balance and brightness control System Requirements gt Compatible Windows 2000 XP Vista and most MAC OS gt Intel Pentium Ill 1 GHz processor or faster gt 256 MB RAM gt CD ROM drive gt 16 bit color display monitor or higher gt Available hi speed USB 2 0 port MODEL DESCRIPTION PDMC Digital Microscope Camera includes mounting bracket DMCB DinoCapture software USB 2 0 extension DMCB Bracket for Microscope Camera PDMC TSPCK Thermo Surgery Platform Camera Kit includes thermo surgery platform with gel pads digital microscope camera mounting bracket DMCB DinoCapture software USB 2 0 extension gel pad reactivation unit SSPCK Standard Surgery Platform Camera Kit includes standard surgery platform digital microscope camera mounting bracket DMCB DinoCapture software USB 2 0 extension 68 BRAINTREE SCIENTIFIC 781 348 0768 a Magnifying Loupes Features gt Set and Forget optics gt Dual hinge design gt Locking interpupillary knob gt Double locking convergence angle Benefits gt Optics are quickly and easily locked in
94. ated stainless steal stylet Ultra thin diameter catheters for applications in mice This 32ga murine catheter is a key component of a withdrawal delivery system specifically developed for use in mice and other small research animals A significant achievement over standard polyethylene based products its material and small size combine to produce a minimally reactive catheter thereby reducing catheter induced artifacts that could obscure experimental observations Suitable for cardiovascular intracranial and other applications Includes gt 11 7cm 32ga 0 010 OD 0 005 ID polyurethane catheter gt Bonded connection assembly flared to accept a 27ga needle gt 0 003 diameter Teflon coated stainless steel stylet to facilitate placement gt Individually packaged MODEL DESCRIPTION CS 32 32ga Intracranial Catheter System Intrathecal Catheter Braintree Scientific s rat intrathecal catheter offers a means for the administration of microliter amounts of drug solution to the lumbar or higher region of the rat spinal cord This catheter system is ideal for use in antinociceptive studies involving rats MODEL DESCRIPTION R ITC Intrathecal Catheter 27 PP Stainless Steel 0 016 dia port plug dozen Visit us online at www braintreesci com 5 7231BRASCI_NOPRICE 12 13 12 11 33 AM Page 6 Catheters Molecular Imaging Catheters Catheter consists of medical grade PTFE tubing SUBL 160 016 O
95. athing Apparatus Anesthetic gas enters the side port and flows to front of nose cone to EZ 320 EZ 330 be inspired by patient Upon j MODEL DESCRIPTION exhalation positive pressure lifts a EZ 320 Oxygen Regulator with H Cylinder fitting preset at 50 psi precision ball valve for 1 way EZ 330 Oxygen Regulator with E Cylinder fitting preset at 50 psi scavenging A rubber balloon is attached at the opposite end acting as a diaphragm Low Pressure MODEL DESCRIPTION Regulator PSI COAX Coaxial Breathing Apparatus Offers precise 5 30 PSI control of CO2 Ka flow Regulator comes with a six foot f N Gas Anesthetizing Box e U hel a that om For use with rodents y oe ieee QF The 0 25 thick transparent 4 me plastic anesthetizing box allows for constant observation while anesthetizing Helps protect against accidental overdosing A F a For use with rats and mice Easy s 4 S Me to move machine tooled sliding top Made of durable plastic this box should last for years Not for use with liquid organic solvents MODEL DESCRIPTION AB 1 Small Box 10 L x 4 W x 4 H e 25 4cm L x 10 16cm W x 10 16cm H MODEL DESCRIPTION AB 2 Large Box 10 L x 8 W x 8 H 25 4cm L x 20 3cm W x 20 3cm H EP 1310 Wall Mount CO2 Flow Meter AB 4 Extra Small Box 4 L x 4 W x 4 H e 10 2cm L x 10 2cm W x 10 2cm H Additional sizes are available please call for a quote MODEL DESCRIPTION EP 1100 Low Pressure Regulator Wall Mount CO Fl
96. ays 4 large combs and a casting stand IN ar 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page 53 Gemini Cautery System Dual Operating Temperatures Battery operated system provides two different operating temperatures 1300 F and 2200 F Easily replaceable autoclavable nickel chrome tips require Convenient battery spacer converts hand piece from high temp to low temp Comes complete with standard AA batteries battery spacer 2 each tips sizes 5mm and 10mm all in a hard plastic case with die cut foam for convenient storage MODEL DESCRIPTION GEM 5917 Gemini Cautery System GEM 5918 GEM 5919 Ideal Micro Drill Replacement Tips 5 x 1mm box of 10 Replacement Tips 10 x 1mm box of 10 Designed for research applications that require surgical burrs and trephines Drill is constructed of light weight aluminum alloy for balance and control and powered by a rechargeable 6 volt nickel cadmium battery Under normal operating conditions unit will function for 8 hours between charges Drill comes with five burrs 0 006mm 0 008mm 0 010mm 1 012mm 1 016mm gt Rechargeable gt Light weight design gt No special tools needed to change burrs gt Hard plastic case with die cut foam for convenient storage gt Excellent balance and handling Specifications Length without burr 17 5cm Diameter 1 9cm Power 6 Volts DC Speed 12 000 rom Stall torque 1 25 oz in MODEL DESRIPTION M
97. cages and pre filled Aquavive water bottles The Innovive disposable rodent caging disaster recovery and emergency planning solution allows user to gt Maintain animals change out schedule with a supply of fresh irradiated Static cages on schedule gt Provide a clean water supply to mice with pre filled water bottles quickly and easily in any location gt Quickly evacuate IVC racks to a new lab location Maximize storage space Innnovive disposable rodent cages and water pack densely they arrive double bagged irradiated and boxed for easy storage and can be accessed as needed Static Disposable Cages All Innovive static mouse cage lids fit the universal cage bottom which provides 81 of floor space and 5 of headroom All Innovive static mouse cage lids are delivered double bagged and irradiated 100 units per box Innovive static rodent cages are designed for stand alone use no ventilated rack required Innocage Static Mouse Specifications Dimensions 14 7 D x 9 2 Wx 5 5 H Uses Universal Cage size 8 8 oz Capacity 1 9 oz food tray gt Static Lid Innovive disposable static cage is designed specifically for Static rodent housing for mice it is also an excellent resource for your Emergency Preparedness Plan gt Water Aquavive Mouse bottle empty or pre filled autowatering and water pouches gt Food Tray Standard stainless steel or all plastic 24 BRAINTREE SCIENTIFIC 781 348 0768 a
98. cision Balances Sartorius M Prove series are ideal balances and scales for educational laboratories and research applications gt Rugged housing made of ABS plastic with maximum overload protection gt Protective flio down and removable plastic cover for shipping protection and stackable storage gt Integrated external calibration weights on models with capacity of 710 grams and below unique durable design for multiple applications gt Applications include counting percent weighing totaling display hold specific gravity mass unit conversion gt 14 mass unit conversions grams ounces pounds pounds ounce pennyweight troy ounces grains Newton carats Taels HK Taiwan oe singapore China user defined gt Parts counting with selectable reference sample 1 100 gt Includes AC adapter gt External one button calibration with 3 weight options gt Lock down capability gt Large 1 white back lit display gt Battery operable with 9V block battery gt External calibration weights are stored in the balance gt Optional RS232 and USB interface kit available MODEL DESCRIPTION READ REPRO PAN SIZE AYS11 M Prove 510g 0 1g 0 1g 5 5 x 5 140 x 128mm AY711 M Prove710g 0 1g 0 1g 5 5 x 5 140 x 128mm AY1501 M Prove 1500g 0 1g 0 1g 5 5 x 5 140 x 128mm AY3101 M Prove 3100g 0 1g 0 1g 5 5 x 5 140 x 128mm Accessories YDP06 Data Printer basic YADAP RS RS232 Adapter with 6 cable YADAP USB
99. cludes membrane for sealing filter top and outlet port to exhaust gas when used as an induction chamber IR Thermometer Quickly determine cage plate temperature before and during recovery Warming Chamber gt Standard small shoe box cage 7 x 11 x 5 gt Standard large shoe box cage 10 x 19 x 8 gt Thermo probe imbedded in bottom of cage floor for accuracy gt Inlet port for gas anesthetic when used as an induction chamber gt Cage floor sealed from heating element Bedding or other material can be used in cage 4 gt Quick pre heating and continuous heating with 700 watt heating element gt Multiple chambers up to 6 can be controlled by one VE 100 controller MODEL DESCRIPTION WWCS Small Induction Warming Chamber Kit Includes 1 small chamber 1 filter top VE 100 controller IR thermometer and operating instructions WWCL Large Induction Warming Chamber Kit Includes 1 large chamber 1 filter top VE 100 controller IR thermometer and operating instructions WCS1 Small Induction Warming Chamber Includes 1 small chamber 1 filter top WCL2 Large Induction Warming Chamber Includes 1 large chamber 1 filter top FWCS Replacement Filter for Small Top 5 pk FWCL Replacement Filter for Large Top 5 pk Other models available online Please visit www braintreesci com for details and pricing Visit us online at www braintreesci com 29 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 30 Tempe
100. control when handlers are relaxed and confident Much better than leather since metal mesh is more flexible is readily cleaned won t stain or corrode and doesn t carry odors Gloves may be worn over surgical gloves Adjustable buckle wrist band prevents slipping Convert right to left by turning inside out Order by size Please note these gloves run large Don t be fooled by imitations MODEL DESCRIPTION SIZE MMG 100 Armour Touch Metal Mesh Gloves Extra Small 7 MMG 100 Armour Touch Metal Mesh Gloves Small 8 MMG 100 Armour Touch Metal Mesh Gloves Medium 9 MMG 100 Armour Touch Metal Mesh Gloves Large 10 Price per glove ambidextrous approximate surgical glove size Guillotine 5 DecapiCones Economical mouse and rodent restrainer MDC 200 Make injections and decapitation quicker and easier with Braintree s DecapiCones Tapered plastic film tubes provide quick and easy restraint of rats mice and other small animals I P injections can be made directly through the film DecapiCones restrain post decapitation kicking and prevent personal contact with feces or urine A unique dispenser holds DecapiCones open and ready for use Simply hold DecapiCone in one hand and introduce the animal with the other Animals enter readily heading for the breathing hole at the small end Then roll and squeeze the large end closed May be used repeatedly for injections and discarde
101. d when soiled For decapitation hold at the rear and insert the small end into decapitator MODEL DESCRIPTION MDC 200 DecapiCones for Mice Includes 2 dispensers 100 bags each Total 200 cones DC 200 DecapiCones for Rats Includes 4 dispensers 50 bags each Total 200 cones DCL 120 DecapiCones for Large Rats 500 800g Includes 4 dispensers 30 bags each Total 120 cones Visit us online at www braintreesci com 57 7231BRASCI_NOPRICE 12 13 12 11 41 AM Page 58 Cli Super Professional Rechargeable Animal Clipper with pense S age A powerful rechargeable clipper designed for all day heavy duty use Clipper will run continuously for one hour with a fully charged battery pack recharges within one hour Maintenance free no oiling or greasing of internal parts Detachable blades for ease of changing and cleaning High speed motor 3600 strokes per minute 8600 rpm Special refresh button recharges and conditions battery to maximum performance overnight On Off switch with lock break resistant Cordless housing contoured to fit your hand All Andis AG and Oster A5 Blades fit super AGR Clipper Push button blade release locks blade into position until changing of blade is desired Power Pack is a high capacity battery pack for extended run time Battery can be charged separately from clipper Additional rechargeable battery packs available Home base is equipped with Sensa Charge a unique chargin
102. d with OPT 1 optical link cable BP 1 Li lon Battery Pack gt Provides 16V 19V or 5V DC output to run either Thermes or a laptop for an extended period of time gt 130 watt hours capacity allows Thermes to operate for up to 100 hours continuously without any additional power source Operating time with a laptop will vary from 3 4 hours in addition to laptops fully charged normal running time gt May be used with the OPT 1 opto isolator cable with adaptor cable gt Charge level LEDs indicate remaining battery life 30 BRAINTREE SCIENTIFIC 781 348 0768 CIN SU Dasylab Operating Software gt For users who already have Labview or Dasylab no additional software is necessary gt Recommended operating software is Dasylab Lite version 9 01 which provides all necessary functions to display and store temperature data in digital and graphical formats in real time Users may customize the display to suit their particular application gt Dasylab Basic version provides additional features for data manipulation and statistical analysis MODEL DESCRIPTION THR USB Thermes USB System with 3 USB cable THR WFI Thermes WFI System with wireless gateway THR OPT 1 Optical Link Cable with built in transmitter receiver THR BP 1 Thermes BP 1 Li lon Battery Pack DASYLAB Lite Dasylab Lite Software DASYLAB Basic Dasylab Basic Software 27 Temperature Controlled Freezing Stage Controller is designed around a new generation of swi
103. ds NIH guidelines recommend sterilizing instruments for small animal surgery Hot glass bead sterilizers are ideal for this application Stays cool to the touch the chassis stays cool even at the end of a full day of operation Air above unit is cool enough to insert an instrument into well without discomfort Insert surgical instrument into well sterilization of inserted parts by dry heat 250 C takes 2 5 seconds Handles of instruments outside heat do not get hot Metal in beads is heated only on the surface not to the depth so cooling is quick after removal Within 30 seconds surgical instruments are cool enough to use Specifications Warm up time 20 min Working temp 250 C approximately 500 F Sterilization time 2 5 sec Well size 20cm deep x 5cm diameter Beads eventually after extensive use wear to powder Replace when it becomes difficult to push instruments in deep enough MODEL DESCRIPTION GER 5287 Dry Sterilizer GER 5289 Glass Bead Refill Package a Sterilizers BIOCLAVE Research Autoclaves wes g B4000 16 B4000 M Steam sterilization of research tools and consumables is convenient and affordable with BIOCLAVE digital research autoclaves With a width of under 18 under 14 for BioClave Mini both models fit comfortably on even the most crowded benchtop Despite the space saving exterior dimensions stainless steel sterilization chambers are surprisingly large accommodating a vari
104. e 108mm 7X 45x 10 5x 67 5x 14x 90x 17 5x 112 5x 2X 34mm 14x 90x 21x 135X 28x 180x 35x 225X ZoomMaster 65 Trinocular or UE tam Z6TD223 ZOBUS Z6TU49 Shown with universal stand inocular ZBB Trinocular ZTB e e Offering cost effective performance flexibility and affordability MS Focus Block FB100 e e ZoomMaster body is available in binocular ZBB and trinocular Z1B l ae Pillar Stand ZP101 versions with 45 inclined eye tubes and side mounted continuous zoom controls A 0 7x to 4 5x zoom range is standard A detente mechanism pane pi i indicates magnification without interrupting observation and ensures ZD223 115V reproducibility of magnification for measurement purposes Universal Stand Trinocular ZTB body is fitted with a photoport for photographic and CCTV ea applications Camera adapters are available and with addition of suitable Dust Cover digital mount or C mount adapters all modern cameras can be fitted to the microscope Illumination options available online at braintreesci com oO Microscopes Accessories 150W Cold Light Illuminator Wide Field Eyepieces Two required MODEL DESCRIPTION ZS WF 10 10x Single ZS WF 20 20x Single ZS WF 25 25x single 150 watt fiber optic cold light illuminator Variable intensity control Three models available single light guide bifurcated light guide or ringlight Color temperature of 3250K MODEL DESCRIPTI
105. e advantage of the superlative heat transfer characteristics of aluminum to better preserve tissue structure during freezing Place fresh tissue in slicer freeze and slice Also suitable for non cryogenic applications Order S for a sagittal style and C for a coronal style MODEL ANIMAL SPECIFICATIONS BS AL 505C Mouse 0 5mm section Coronal BS AL 505S Mouse 0 5mm section Sagittal BS AL 5000C Mouse 1mm section Coronal BS AL 5000S Mouse 1mm section Sagittal BS AL 605C Rat 0 5mm section Coronal BS AL 605S Rat 0 5mm section Sagittal BS AL 6000C Rat 1mm section Coronal BS AL 6000S Rat 1mm section Sagittal Precision Brain Slicer The Precision Brain Slicer is designed to aid the basic research scientist in free hand dissection of discrete regions of rodent brain Allows investigator to slice either coronal or sagittal sections through the brain including the olfactory bulbs at intervals as small as 1mm All PBS s are identical to insure reproducible sections on a day to day year to year basis Applications gt Biochemical Pharmacology The reproducible removal of small brain regions for biochemical analysis such as the determination of neurotransmitter and metabolite concentrations Individual brain areas may be either dissected or micropunched from slices formed gt Anatomy Precise blocking of the brain prior to microtome sectioning gt Neurophysiology Reproducible blocking of the brain prior to vibrotome sectioning
106. e section for digital microscope attachments MODEL DESCRIPTION 39 OP Operating Board 2 Deltaphase Pads and 2 Insulators 39 DP Includes 3 Deltaphase Pads and 3 Insulators only no board Instruments shown not included Rodent Work Stand is designed to support rats mice and similar small rodents in a stable and comfortable position for the technician during endotracheal intubation and intratracheal dose instillation and other similar procedures 12 wide x 14 deep x 5 375 high when flat tilted it is 9 5 high Flat 30 48cm x 35 56cm x 13 65cm tilted 24 13cm high Heated work stand kit converts this work stand to a heated work stand Visit our website at www braintreesci com MODEL DESCRIPTION RW A3467 Rodent Work Stand RW HHP Heated Pad Kit 14 BRAINTREE SCIENTIFIC 781 348 0768 7231BRASCI_NOPRICE 12 13 12 11 35 AM Page 15 DecapiCones The economical mouse and rodent restrainer Make injections and decapitation quicker and easier with Braintree Scientifics DecapiCones Tapered plastic film tubes provide quick and easy restraint of rats mice and other small animals l P injections can be made directly through the film DecapiCones restrain post decapitation kicking and prevent personal contact with feces or urine A unique dispenser holds DecapiCones open and ready for use Simply hold the DecapiCone in one hand and introduce the animal with the other Animals enter readily heading for
107. eds and tilt angles user can set both parameters to match vessel size and volume of liquid being mixed User can adjust both parameters to match vessel size and volume of liquid being mixed yielding optimum results Rocking speed and tilt angle are both easily adjustable in seconds At low speeds and minimal tilt angles both models 2D for see Saw motion or 3D for gyratory motion provide a gentle wave effect for non foaming mixing as is required for most blot washing and gel work When set to higher speeds and more extreme tilt angles they produce aggressive agitation for vigorous sample mixing Dual platform option expands workspace BenchRocker 2D and 3D can accept stackable platforms 2 75 clearance All platform mats are autoclavable Both models have maintenance free brushless motors and are safe for use in cold rooms and incubators Mix and vortex any size tube Variable speed Vortex Mixer VX 200 provides fast efficient mixing with minimal vibration Features a true circular orbit that allows for even distribution of vortexing across the entire speed range CombiCup head supplied as standard accepts many different tube sizes A full range of accessories is available to accommodate most common laboratory tubes and plates Continuously variable soeed makes the Vortex Mixer VX 200 MODEL DESCRIPTION useful for a variety of applications from gentle mixing to resuspending BR 2000 BenchRocker 2D variable speed rocker p
108. ellets The unit has a circular orbit rather than elliptical allowing a vortexing with flat mat platform l l motion hieved even at low speeds The Vortex Mixer VX 200 can be BR 2000 STACK Optional stacking platform 14 x12 with flat mat ale pi iA es a p de When in h mode th BR 3D2300 BenchRocker 3D variable speed rocker operater in elt er touch or continuous mode When in touch mo e the gt with dimpled and flat mats motion is activated by depressing sample head and stopped by removing BR 1000 STACK Optional stacking platform 12 x12 with flat mat pressure If the unit is set in the on position the Vortex Mixer VX 200 will PN TOON TAE Oe end DANO ie pA wat operate continuously until turned off CombiCup head can be used with a BR 0718 LaBungee elastic tie downs with hooks pack of 4 l l single tube or a whole handful Unique over molding technology used in the manufacture of CombiCup provides a sturdy plastic core surrounded with Benchmixer pe yp nonslip TPE Optional heads available eS e a BenchMixer sets the standard in vortex gt Powerful reliable motor mixing With advanced Q Drive technology BenchMixer provides smooth instant vortexing of even the largest sample sizes including full 50ml tubes Unique counter balance system gt Optimized counter balance system minimizes vibration gt Circular orbit for effective vortexing at any speed gt Standard CombiCup accepts a vari
109. eotaxic Instrument was developed for the expanding growth of research being conducted with knock out and transgenic mice It allows the user to perform surgical procedures on two mice at one time Precision alignment is accurate to 10 microns in all directions Stoelting has created two stereotaxic instruments on a single base with ear bar slots on both sides A manipulator arm controls medio lateral and vertical positioning via lead screws and antero posterior movement via dovetail slide with 80mm of travel possible in each direction allowing access to both ear bar locations Ear bars may be independently adjusted in height to level the skull Delrin ear bars with tapered points specialized jaw holder cuffs or rubber pads are included Ed MODEL DESCRIPTION 51725 D Digital Just For Mice 51725 Non digital Just For Mice Visit us online at www braintreesci com 77 p 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 78 Matrices Acrylic Matrices High grade acrylic matrices are an economical method to obtain even slices of brain tissues from rats and mice These units include the spinal and olfactory bulb notches Order S for a sagittal style and C for a coronal style MODEL ANIMAL SPECIFICATIONS BS 5000C Mouse 1mm section Coronal BS 50008 Mouse 1mm section Sagittal BS 6000C Rat 1mm section Coronal BS 60008 Rat 1mm section Sagittal Anodized Aluminum Brain Slicer Ideal for frozen tissues Tak
110. erile Bulk 100 PET Q100 100100S 100ml Sterile Individually Wrapped 100 PET Q100 100200S 100ml Sterile Bulk Packaged 5 bag 200 PET Q100 10050 100ml Non Sterile Bulk 50 PET Q100 10050S 100ml Sterile Individually Wrapped 50 PET Q200 100100 100ml Non Sterile Bulk 100 PS Q200 100100S 100ml Sterile Individually Wrapped 100 PS Q200 100200S 100ml Sterile Bulk Packaged 5 bag 200 PS Q200 10050 100ml Non Sterile Bulk 50 PS Q200 10050S 100ml Sterile Individually Wrapped 50 PS Q300 100100 100ml Non Sterile Bulk 100 HDPE Q300 100100S 100ml Sterile Individually Wrapped 100 HDPE Q300 100200S 100ml Sterile Bulk Packaged 5 bag 200 HDPE Q300 10050 100ml Non Sterile Bulk 50 HDPE Q300 10050S 100ml Sterile Individually Wrapped 50 HDPE IN ar 7231BRASCI_NOPRICE 12 13 12 12 20 PM Page 41 Labpette Discovery Pipettes Autoclavable pipettes designed for exceptional comfort and accuracy Precision pipettes are designed for exceptional comfort and accuracy Lightweight and well balanced they fit comfortably in either right or left hand with large digital display visible to user Chemically resistant maintenance free seals and finely polished pistons provide unsurpassed accuracy sample after sample Continuously adjustable digital micrometer is slightly recessed to prevent unintentional change and is protected from effects of thermal expansion by insulated body of the pipette For convenience volume can also be adjusted by turning push but
111. ers the ethics of animal experimentation through a complete review of European and North American legislation on the topic It discusses alternatives to animal experiments including the use of isolated organs cell cultures and computer simulations The Anatomy of The Rat turmce Chace irrgeng MODEL TITLE LAS Handbook of Laboratory Animal Science Volume 1 ee 1 LAS II Handbook of Laboratory Animal Science Volume 2 rite ee LAS III Handbook of Laboratory Animal Science Volume 3 Manual of Microsurgery on the Available only from Braintree Scientific Laborato ry Rat This classic book offers basic reference for all researchers using laboratory rats It includes 339 precisely detailed presentations of the rat numerous colorful hand sketched skeletal diagrams provide a thorough analysis of the anatomy of a rat The large format 8 5 x 11 clarity of the presentations and its spiral binding allowing it to lay flat contribute to this valuable researcher s assistant Whether in the library or lying on a laboratory bench this reference book is a valuable tool In our opinion no other textbook even An up to date didactic manual describing experimental microsurgical techniques in great detail The manual includes general information about rat i e anatomy anaesthesia and sterility and a wide range of general techniques Sections on experimental techniques are covered in the greatest depth All essential Steps that are taken duri
112. es vials or other containers with a liquid The learn and repeat mode of the BS 900 Peristaltic Pump makes even the smallest of businesses highly productive right from day one BS 900 is equipped to be used in many settings from small business to large factory floor Pump can be integrated into existing production lines or simply stand alone BS 900 comes fully programmable and can be operated manually or with a PC through a RS 232 communication port at no extra cost Flow rates vary from a minimum of 0 5ml hr to a maximum of 1250ml min The pump s specialty is its small scale production dispensing It will fill numerous bottles vials etc with fluids of all types Equipped for mass production dispensing at a price affordable for small business this pump is a great deal no matter your purchasing power Syringe Pumps BS 8000 and BS 9000 Programmable Syringe Pumps Braintree Scientific has low cost syringe pumps in stock for use in biomedical research laboratories UL Listed CE APPROVED Built for Automation gt Operates stand alone or from a computer gt Infusion and withdrawal Set a single pumping rate set a dispensing volume or program up to 41 pumping phases that change pumping rates set dispensing volumes insert pauses contro and respond to external signals sound the buzzer gt Create expandable and reconfigurable multi syringe systems by attaching pumps to each other General Features gt I
113. ether SAH 14 Standard Harness with 14 tether SAH 18 Standard Harness with 18 tether International and US patent 7 665 424 27 Rat Tethers Quick Connect Male Male Spring Tether The Quick Connect Spring Tether is intergraded with a polyurethane extension line that is housed within Tether has male luer ends that connects to Quick Connect Harness and Quick Connect Swivel Individually packaged and ETO exposed DESCRIPTION MODEL QCT 12 Quick Connect 12 male to male spring tether QCT 14 Quick Connect 14 male to male spring tether QCT 18 Quick Connect 18 male to male spring tether Male Spring Tether For researchers that wish to use a standard swivel or stainless steel swivel with the Quick Connect harness simply use a tether extension line with intergraded male end Individually packaged and ETO exposed MODEL DESCRIPTION mann M23T 12 12 Male luer spring tether with Catheter to fit 23G swivel M23T 14 14 Male luer spring tether with Catheter to fit 23G swivel M23T 18 18 Male luer spring tether with Catheter to fit 23G swivel M22T 12 12 Male luer spring tether with Catheter to fit 22G swivel M22T 14 14 Male luer spring tether with Catheter to fit 22G swivel M22T 18 18 Male luer spring tether with Catheter to fit 22G swivel M25T 12 12 Male luer spring tether with Catheter to fit 25G swivel M25T 14 14 Male luer spring tether with Catheter to fit 25G swivel M25T 18 18 Male luer spring tether with Catheter to
114. ety of liquids media instruments glassware plasticware and other common laboratory items Both models include a mechanical and electrical safety interlock that prevents the door from being opened until pressure has reached zero PSI Three trays two with the BioClave Mini are supplied with each unit along with a convenient tray removal tool With large digital displays and fully automatic operation all segments of sterilization cycle fill sterilize exhaust and dry commence and run to completion by simply pressing the start button BIOCLAVE 16 AutoClave 16 liter BioClave offers three cycle options standard programs which are preset for sterilization of liquids wrapped instruments or unwrapped instruments plasticware A fourth Dry Only option is also available for additional drying time at the end of a cycle For special applications requiring variations in cycle parameters all settings on the BioClave 16 are fully adjustable BIOCLAVE Mini AutoClave 8 liter BioClave Mini is preprogrammed to meet basic sterilization needs Although temperature can be selected at either 121 C or 134 C Sterilization time is fixed MODEL DESCRIPTION B4000 16 Bioclave 16 AutoClave B4000 M Bioclave Mini Autoclave Sentry Ultrasonic Cleaner gt TT Sentry Ultrasonic Cleaner is a high efficiency A cleaner specially developed to clean surgical instruments Ultrasonic waves pump micron sized bubbles into the water Bubbles
115. ety of tube sizes gt Full range of accessories creates maximum vortexing action while Specifications minimizing noise and excessive vibration Speed range 0 3 400 rom Vortex a single tube or a handful with the resulting in quieter more efficient and operating modes touch or continuous longer lasting operation Ambient operating range 4 to 65 C Nonslip TPE Other features include no walk suction feet cold room incubator MODEL DESCRIPTION compatibility and spill proof electronic controls s0200 Vortex Mixer gt Powerful Motor for instant vortexing Optional Heads Touch or Cont 0 ti 32 x 0 2ml tubes or 4 PCR strips i out Of VONUINUOUS Uperation S0200 22 1 microplate or 64 x 0 2ml tubes or 8 PCR strips gt Variable Speed Control from 200 to 3200 rom S0200 23 8 x 15ml and 8 x 12 13mm diameter tubes continuously MODEL DESCRIPTION S0200 24 6 x 50ml tubes adjustable variable l l S0200 25 12 x 1 5 2ml tubes held horizontally BV1000 BenchMixer Vortex Mixer S0200 26 4 x 15ml tubes held horizontally BV1000 FLAT Optional 3 flat head l S0200 27 2 x 50ml tubes held horizontally BV1000 COMBO Optional combination head for tubes and microplates Holds 66 tubes 38 x 1 5ml and 28x 0 5ml or one microplate 46 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page 47 Orbit 300 Multipurpose Vortexer Three interchangeable platforms available separately accommodate a variety of
116. event condensation on side wall gt Recommended for use with low volume reactions lt 20uL MODEL DESCRIPTION QTY BX SP0085 Low Profile PCR strip tubes strips of 8 10 packs of 12 strips 38 BRAINTREE SCIENTIFIC 781 348 0768 P PCR Strip Caps mamama E E OG G N u N N gt Suitable for use with 96 well PCR plates as well as standard and low profile strip tubes gt Flat caps have labeled end tabs for strip orientation and removal gt QPCR strip caps are made from specially formulated clear polypropylene and have ultra clear highly polished surface Ideal for QPCR and fluorescence detection MODEL DESCRIPTION QTY BX SP0030 Flat PCR Strip Caps strips of 8 10 packs of 12 strips SP0516 Domed PCR Strip Caps strips of 8 10 packs of 12 strips SP0100 QPCR Strip Caps Flat strips of 8 10 packs of 12 strips SP0078 Strip Cap tool sold individually each CoolCube Microtube and Microplate Cooler CoolCube is designed to store samples safely on lab bench without sample degredation due to temperature increase or fluctuation Constructed of DuraStar a high strength polymer and a proprietary gel refrigerant CoolCube maintains temperature at approximately 0 C for up to four hours simply place the CoolCube in a freezer overnight and it s ready for use keeping samples cool and safe at the bench without messy ice buckets or wet tubes One side of CoolCube can be used as a convenient PCR workstation with wells
117. fective core body warming and cooling F therapy with precise temperature control It Cze helps prevent body heat loss and hypothermia during surgery and recovery Cooling setting delivers 50 F 10 C therapy gt For warming therapy two selections are available low 100 F 38 C or high 107 F 42 C gt Three layer safety system with dual temperature sensors dual microprocessors and a mechanical thermostat to ensure patient safety gt Illuminated LED control panel comfortable handle built in hose cord storage and translucent water reservoir designed for ease of use gt Uses tap water and ice cubes if cooling GAYMar MODEL DESCRIPTION TP 700 Gaymar Heating Cooling Water Pump TP D22C Gaymar Multi T Pad 15 x 22 Single Patient each TP R22G Multi T Pad 15 x 22 Reusable each TP D3E Multi T Pad 3 x 23 Single Patient 10 case TP D12E Multi T Pad 13 x 18 Single Patient 10 case Heat Therapy Pump The safest and most accurate localized heat therapy system available Bright and easy to read display provides continuous real time temperature readings Digital controller uses proprietary software to manage users prescribed set point temperature to within 1 F Three temperature safety limits guard against possibility of overheating and Hi Limit Switches can be tested without taking unit apart Specifications Set point range 75 F Off to 107 F Set point accuracy 0 5 F Flow rate gt 15gph Reservoir 50
118. ferent height tubes as well as plates A compression mat is provided to ensure even pressure when using plates For optimum performance temperature of the lid may be programmed To ensure that users never come in contact with hot surface lid slides back and away from samples In addition to eliminating risk of burns this also provides complete access to samples Lid can also be flipped up for cleaning Specifications Sample capacity 1 x 96 well plate 12 8 x 0 2ml strip tubes 96 x 0 2ml tubes Programmable temperature range 4 C to 99 9 C Temperature accuracy uniformity 0 5 C 0 5 C Heating cooling method Peltier Maximum heating cooling rate 4 C 3 C per second Dimensions 24cm x 42cm x 25cm gt Temperature control calculated or block gt Temperature range of 6 segment blocks 30 C to 99 C Temperature of 6 segment blocks can be set independently gt Maximum temperature difference between 6 segment blocks 24 C gt 6 segement temperature blocks 6 temperature blocks in 4 x 4 well format gt Programmable lid temperature 60 to 65 C 100 to 115 C gt Program memory 200 complete programs gt Temperature increments decrements gt Time increments decrements gt User program folders 50 sets gt Allows for password protected programs gt Communication USB and RS232 ports MODEL DESCRIPTION TC9610 MultiGene Optimax Thermal Cycler IN ar 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page
119. fit 25G swivel Spring Tether Stainless steel spring tethers for single luer or standard swivel applications MODEL DESCRIPTION QT 12 12 Spring Tether QT 14 14 Spring Tether QT 18 18 Spring Tether 27 Luer Swivels Quick Connect Swivels There is no need to match tubing diameters with swivels any longer A luer lock on both outlets of dual luered Quick Connect swivel eliminates these complications for good Generally used with the Quick Connect tether the Quick Connect swivel is also available with a luer only on one outlet Use the Quick Connect fittings only when needed Lp Ele Ll SLUT IE LIE LIS LLIB LIG LULU tliclin tian TETTU TEETETETTETE stat ioc rst MODEL QCS D Quick Connect Swivel Dual Luered QCS S Quick Connect Swivel Single Luer for use with DESCRIPTION Standard harness with tether block Visit us online at www braintreesci com 59 7231BRASCI_NOPRICE 12 13 12 1 54 PM Page 60 Collars Tethers and Slings 27 Rodent Sling and Restraint Cover slings can be used to securely restrain rodents during many t procedures Choice of restraint in a many sizes and range of adjustment make rodent sling a valuable asset to any laboratory setting Y Other small animal species may also be restrained using same K frame with suits and slings available X for mice and guinea pigs Frame Polypropylene base with supports made from stainless steel one inch thick base material provide
120. flow to electrodes only when lid is in place If lid is removed while system is operating current is immediately shut down Lid of the box is vented to dissipate heat produced during electrophoresis A clear window over the gel platform aids in visualizing the gel while it is running Specifications Output voltage current 10V to 150V 10 to 400 mA Timer 0 99 hr or continuous audible alert Program memory Last programmed parameters saved Electrical universal 100V 240V 50 60 Hz Overall Dimensions 10 x 6 7 x 2 5 24 5cm x 17cm x 6 2cm Gel Capacity 1 large 12 5 x 12cm 2 small 12 5 x 6cm 4 micro 6 x 6cm gt Power 150v 400ma gt Control set voltage amperage and time gt Flexibility runs 6 x 6cm to 12 5 x 12cm gels gt Throughput up to 112 samples at once gt Convenience casting set and combs included ia ro i m SS a E MODEL DESCRIPTION E0160 Enduro Gel XL Electrophoresis System includes gel tank power supply and standard casting set E0161 Large Gel Tray Set 12 5 x 12cm pack of 2 E0162 Small Gel Tray Set 12 5 x 6cm pack of 2 E0163 Micro Gel Tray Set 6 x 6cm pack of 4 E0164 Large Comb Set 14 28 teeth reversible pack of 2 E0165 Small Comb Set 5 8 teeth reversible pack of 2 E0166 Micro Casting Set includes 4 micro gel trays 2 small combs and a casting stand E0167 Casting Stand for all gel sizes E0168 Standard Casting Set includes 1 large and 2 small gel tr
121. fortless yet accurate cuts gt Fully extended blad M raihi through the toughest tissue Shanks are tempered to allow proper flexibility set cee ele S rar and comfort Finger rings are well rounded and polished allowing better feel gt gt Top activation allows for ambidextrous use while preventing finger fatigue gt Fully enclosed front enhances blade stability and security Preventnging gu gt Audible clicks help confirm proper blade position MODEL DESCRIPTION l SuperCut Surgical Scissors Sharp Blunt gt Final lock for safe handling and disposal SC508 Surgical Scissors Straight 5 5 139 7mm gt Non slip ergonomic handle with metric scale SC511 Surgical Scissors Curved 5 5 139 7mm gt Color coded slider button for easy blade size identification SuperCut Metzenbaum Scissors Delicate gt Highest quality standards SC523 Straight 4 5 114 3mm gt Uses premium GLASSVAN blades Computerized grinding and 80525 Curved 4 5 114 3mm proprietary polishing processes for the blades ensure consistent SuperCut Iris Scissors SC528 Straight 4 5 114 3mm SC529 Curved 4 5 114 3mm Tungsten Carbide Iris Scissors clean sharp cutting edges gt Scalpel blades produced from high quality high durability Swiss stainless steel a SC405 Straight 4 5 114 3mm gt Scalpels manufactured in ISO 13485 certified facilities SC406 Curved 4 5 114 3mm MODEL SIZE SSS 10 10 Specialty Scissors SSS 11 11 SSS 12 2 I
122. fy in file to send a different pumping program of each pump in pump network gt Automatically change pumping rates gt Insert timed delays between dispenses Multi syringe pump has all programming features of the single syringe pump with either 6 or 8 syringes MODEL DESCRIPTION BS 8000 Holds 1 Syringe up to 60cc BS 9000 2 Holds 2 Syringes up to 60cc BS 9000 6 Holds 6 Syringes up to 50cc BS 9000 8 Holds 8 Syringes up to 10cc BS 9000 12 Holds 12 Syringes up to 3 5cc IN ar 7231BRASCI_NOPRICE 12 13 12 11 41 AM Page 63 a BS 500 OEM Application Syringe Pump Specifically built for automation this OEM pump operates from a computer gt Does not have a built in user interface gt Chassis mountable 9 5 L x 4 25 W x 4 125 H 23 5 X 10 8 x 10 5cm gt Operates from a 12V DC power source gt Holds one syringe up to 60cc gt Infusion rates from 0 73uL hr 1cc syringe to 2100ml hr 60cc syringe gt Includes all advanced functions and programming features of BS 8000 family gt Download free pump terminal emulator gt Custom modifications to the mechanics and firmware are available gt Computer controllable networkable up to 100 pumps stand alone operation pre program the pump with a dispensing program then operate the pump from an attached foot switch button or I O controller Add the OEM Starter Kit to run as a fully functional stand alone pump Open chassis design easily mounts into your syste
123. g Visit us online at www braintreesci com 41 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 39 AM Page 42 a Centrifuges 27 Hermle Universal Centrifuge MODEL DESCRIPTION C0306 Hermle Z306 Universal Centrifuge C0326 12 Rotor 4 x 100ml economy C0326 72 Rotor 4 x 100ml swing out without buckets C0326 72C Rotor 4 x 100ml swing out with buckets C0036 16 Rotor 2 x 3 Microplate C0036 19 Rotor 30 x 15ml fixed angle CO0200 10 Adapter 10 15ml round bottom C0326 96 12x 15ml fixed angle rotor y r C0200 17A Adapter 5 7 10ml BF o C0230 20 Adapter 1 5ml aad _ a 0326 97 6x 50ml fixed angle rotor eee C0232 8B Adapter 15ml conical round bottom i C0232 9B Adapter 7ml C0230 41 Cushion for 12 x 75ml C0326 24 Rotor 24 x 1 5 2ml C0326 24H Rotor 24 x 1 5 2ml hermetically sealed CO0036 17 Rotor 30 x 1 5 2ml C1205 Adapter 0 5 0 6 ml C1206 Adapter 0 4 0 25ml C1222 Adapter 0 2m gt Maintenance free induction drive gt Microprocessor with large LCD display gt Lid lock gt Automatic rotor identification system with over speed protection immediately upon rotor insertion gt Active imbalance identification and cut off rotor specific gt Imbalance tolerant drive gt A large variety of rotors and accessories available gt Manufactured according to international safety regulations i e IEC 61010 gt Audible signal at the end of each run with several melody options gt Rotor excha
124. g on control inputs Configurable TTL operational trigger gt Power Failure Mode Restarts pumping program after a power interruption gt Audible alarm MODEL DESCRIPTION BS 900 Programmable Peristatic Pump gt Automatically pause program and wait for user to continue the dispense gt Synchronize dispenses with other equipment or pumps to change pumping rates in reaction to a sensor or signals from other pumps gt Send logic signals to other equipment Change pumping rates in reaction to a sensor gt Program audible alarm to beep at any time to alert operator gt Enter pumping program from keypad or download from a computer gt Operates stand alone from RS 232 computer port or TTL logic interface gt Total volume pumped separately accumulated for infusion and withdrawal Programming Features gt 41 programmable phases gt Set event interrupts from external signals to cause automatic jumps to another part of the program gt Conditional jumps based on external inputs Nested Loops gt Repeat a section of the program continuously or a set number of times Program Editing Functions gt Insert and delete program phases gt Simplifies program development and updating gt Allows quick removal or addition of program phases gt Enter programs from keypad or computer gt Download or upload pumping programs from or to a computer Store dispensing programs in a file on computer then download to one or more pumps Speci
125. g system that will not overcharge battery LED lights indicate charging mode Recharges and conditions battery to maximum performance MODEL DESCRIPTION CLP 64800 Super Professional Rechargeable Clipper Replacement Blades CLP 64084B 40 Surgical S S Detachable CLP 64071B 10 Medium Cut Detachable Blade CLP 64160B Ultrafine Blade Surgical S S Detachable Miscellaneous Accessories CLP 64710 Super Professional Charger CLP 64715 Super Professional Battery Pack ers and Trimmers Battery Operated Trimmer Easy to use anywhere Includes 40 ae Stainless steel blade tube of oil batteries and blade brush Cordless MODEL DESCRIPTION CLP 22965 Battery Operated Trimmer Replacement Blades CLP 22880B 40 S S Replacement Blade Rechargeable Trimmer Quiet heavy duty motor driven rechargeable trimmer equipped with super fine tooth blades for close trimming gt Ni MH battery for superior performance and less memory effect gt Stainless steel blades will not rust Cordless MODEL CLP 32375 Replacement Blades CLP 32350B S S Replacement T Style Blade DESCRIPTION Rechargeable Trimmer 58 BRAINTREE SCIENTIFIC 781 348 0768 a Pocket Pro Pet Trimmer Light duty trimmer ideal for precision trimming and great for touch ups gt Compact size easily fits in palm of hand gt Cordless battery operated for convenient use anywhere gt High carbon precision ground steel blades stay sharper longer
126. gas exposure System includes gt EZ 150C Classic Vaporizer Unit gt EZ 109 Multi Animal Non Rebreathing Unit gt EZ 178 Mouse Rat Sure Seal Induction Chamber gt EZ 163 Induction Chamber Warmer gt EZ 200 Water Heating Circulation Pump gt EZ 258 Charcoal Filters 8 gt QO Regulator specify which Oxygen Regulator is required EZ 320 industrial CGA540 EZ 330 medical yoke fitting gt Mouse Rat nosecones nosecone plugs charcoal filter stand and all connecting tubes MODEL DESCRIPTION EZ 7350 Multi Animal Systems a Anesthesia Line Stereotaxic Small Animal System Featuring the Rat Stereotaxic Breather Breather is specifically designed for use with rats Integrates easily with standard stereotaxic equipment Incorporates adjustable nose bridge lower jaw support and ear bars Includes heating elements for maintaining animal temperature during procedures System includes gt EZ 150C Classic vaporizer unit gt EZ 107 Rat stereotaxic non rebreathing unit gt EZ 178 Mouse Rat Sure Seal induction chamber gt EZ 211 Mouse Rat Thin Line stainless steel heated surgical waterbed 10 L x 3 5 W x 1 H gt EZ 163 Induction chamber warmer gt EZ 200 Water heating circulation pump gt EZ 258 Charcoal filters 8 gt QO Regulator specify which Oxygen Regulator is required EZ 320 industrial CGA540 EZ 330 medical yoke fitting gt Mouse Rat nosecones nosecone plugs charcoal filter stand and all
127. ggested rather than risk particulate from tap water Includes gt Blue hose gt Canister nebulizer gt Chrome DISS fitting at top of canister gt 7 crush proof Oz tubing from chrome fitting to air compressor and Schuco air compressor MODEL DESCRIPTION NEB CAN Canister Nebulizer Modified Mouse Pie Cage sold separately 22 BRAINTREE SCIENTIFIC 781 348 0768 Size 1 lt 25G Mice Fixture Body Diameter is 1 25mm MODEL CONFIGURATION MHS1 LF Left Flank Fixture and Shield 04240802 Left Flank Fixture only 06050801 Left Flank Shield only MHS1 RF Right Flank Fixture and Shield 05140805 Right Flank Fixture only 05120901 Right Flank Shield only MHS1 DF Dual Flank Fixture and Shield 05140803 Dual Flank Fixture only 03170901 Dual Flank Shield only MHS1 NF No Flank Fixture and Shield 04240800 No Flank Fixture only 05120801 No Flank Shield blank only Size 2 Fixture Body Diameter is 1 375 35mm MODEL CONFIGURATION MHS2 LF Left Flank Fixture and Shield 07030802 Left Flank Fixture only 05120904 Left Flank Shield only MHS2 RF Right Flank Fixture and Shield 07030804 Right Flank Fixture only 05120905 Right Flank Shield only MHS2 DF Dual Flank Fixture and Shield 07030806 Dual Flank Fixture only 05120906 Dual Flank Shield only MHS2 NF No Flank Fixture and Shield 07030803 No Flank Fixture only 05120903 No Flank Shield blank only 9cc Medication Nebulizer Pour in whatever dosage of liquid medicine top off with disti
128. gt Sealing options Heat sealing adhesive MODEL DESCRIPTION sealing and mat caps SP0127 Box with 5 packs of 5 each gt SBS footprint stackable robot compatible MODEL DESCRIPTION SP0092 Box of 50 individually wrapped 36 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 37 PCR Plates Tubes and Seals 2 2ml Square Well Conical Bottom gt Conical bottom aids in complete sample retrieval gt Sealing options Heat sealing adhesive sealing and mat caps lt P gt SBS footprint stackable robot compatible MODEL DESCRIPTION SP0103 Box of 50 individually wrapped 384 Well Plate 120ul Square Well Pyramidal Bottom gt Separate raised rims around each well and around plate perimeter aids in sealing and prevents cross contamination gt Sealing options Heat sealing adhesive sealing gt SBS footprint stackable robot compatible MODEL DESCRIPTION SP0089 Box with 5 packs of 10 each 250ul Square Well Conical Bottom gt Conical bottom aids in complete sample retrieval gt Sealing Options heat sealing adhesive sealing Tea f gt SBS footprint stackable robot compatible MODEL DESCRIPTION SP0925 Box with 5 Packs of 10 each 96 Well Mat Caps Round gt Flexible mat designed to seal round well storage plates gt Pierceable version is solvent resistant including DMSO MODEL DESCRIPTION QTY SP0077 Round Cap Piercable DMSO Resistant flexible
129. heter port can be added to the R JVC R CAC and the R FAC FVC at an additional cost This disk serves to anchor the catheter if the wound clip is dislodged or removed If ordering please add a D to the end of the model number MODEL DESCRIPTION CATHETER TIP LENGTH TOTAL LENGTH R JVC Rat Thoracic Jugular Vein 32mm 115 120mm R CAC Rat Thoracic Carotid Artery 26mm 110 115mm M JVC Mouse Thoracic Jugular Vein 13mm 98 60mm M CAC Mouse Thoracic Carotid Artery 11mm 56 58mm PP 23 Stainless Steel 0 025 dia port plug dozen 4 BRAINTREE SCIENTIFIC 781 348 0768 MODEL DESCRIPTION R FVC Rat Femoral Vein Catheter R FAC Rat Femoral Artery Catheter M FVC Mouse Femoral Vein Catheter catheter body length 45mm M FAC Mouse Femoral Artery Catheter catheter body length 45mm PP 23 Stainless Steel 0 025 dia port plug dozen Suitable for blood sampling and or drug infusion in either the femoral artery or femoral vein The rat femoral catheter is available in three different sizes of catheter body length large 160 170mm medium 140 150mm and small 120 130mm Please specify when ordering BTing Catheters For rodent vascular applications T What is Bump tubing BTing Bump tubing is a continuous length of Tecoflex polyurethane tubing with a tapered transitional section resulting in catheter tubing with the intravascular tubing section having an ID OD of 0 012 0 025 and an extravascular tubi
130. hm program that calculates sample temperature based on volume and triggers heating and cooling accordingly to provide quick temperature change in sample and minimize over and undershoot a 50 BRAINTREE SCIENTIFIC 781 348 0768 a Programming is very intuitive Large back lit LCD displays alphanumeric characters and a graphical representation of program steps Simple on screen instructions guide user through programming process MultiGene OptiMax is provided with common pre programmed protocols which are easily edited by navigating to appropriate parameter with arrow keys and entering a new value A variety of applications can be performed from single temperature soaks to sophisticated multi step programs All of these are easily set up Time or temperature of a cycling step can be automatically increased or decreased during successive cycles This is useful for touchdown applications and extending annealing times as enzyme is depleted Programs may also be paused while running During operation actual times and temperatures are displayed Estimated run times are automatically calculated and a log of the last run can be displayed or downloaded to a PC Gradient Capability MultiGene cycler block can be programmed to operate with uniform temperature across the block for consistent results or with a temperature gradient for protocol optimization Heated lid is fully adjustable to provide proper pressure for use with dif
131. i 10 88mm 119mm 1 8 24 K1531 5000mI 500ml 10 190mm 228mm 25 2 Coplin Staining Jar 5 10 Slide Unit Holds ten 3 x 1 75mm x 25mm slides i q Bei 4 which extend above the opening Can be manipulated without using forceps Screw cap made of linerless white polypropylene which reduces solvent evaporation and spills during Storage Rectangular base holds approximately 55ml MODEL DESCRIPTION QTY CASE Approximate inside dimensions 26mm L x 26mm W x 70mm D 900520 Coplin Jar with PP Screw Cap cece ee 6 900522 Replacement Cap 58 400 0 0 ce aes 6 a Bottles and Flasks Hybex Reusable Media Bottles Manufactured from high quality borosilicate 3 3 glass With their superior u chemical resistance these bottles are ideal biological fluids and a variety of other aqueous and nonaqueous solutions A low coefficient of thermal expansion 3 3 provides temperature resistance that is far superior to that of standard lab glass or soda lime glass Hybex glass can withstand temperatures from and dry heat sterilization chambers All hybex media bottles include a drip free sealing ring as well as a standard blue polypropylene GL45 sealing cap Bottles are also available with green purple white and yellow caps or in an assortment pack containing two of each color Material Hybex borosilicate glass 3 3 Cap thread size GL45 Temperature range 70 to 500 C Sterilization Autoclave or d
132. ic range of 75 100 F wherever the patient lies This combination of radiant heat and convection currents preclude the use of a pump fan or motor which may spark and ignite with the use of oxygen Uniform temperature is achieved without hot spots and safe heat is assured because the animal is surrounded by comforting warmth just like a hot water bottle making Thermocare Warmers a critical part of recovery for reptiles rodents and animals Vents on the top of the heated or unheated covered units allow warm air to rise and escape with any carbon dioxide build up It is the combination of therapeutic heat with respiratory therapy that creates a stand alone ICU Intensive Care Unit For example with the addition of a cover domed or flat which allows respiratory therapy the Thermocare Warmer becomes an ICU To meet your specific needs ThermoCare offers a wide selection of intensive care units Intensive Care Unit with Dome Cover ThermoCare s Intensive Care Units ICUs allow a full latitude of respiratory therapeutic procedures including administering oxygen humidity and nebulization in combination with heat Units accommodate animals up to 20 pounds small size or up to 80 pounds medium large sizes The optional perch facilitates treatment for birds Specifications Small 22 25 L x 15 5 W x 14 75 H Medium 31 L x 25 W x 24 H Large 39 75 L x 25 W x 24 H Dome covered units include gt Water
133. ide Rack with handle attached stainless steel 3 40 BRAINTREE SCIENTIFIC 781 348 0768 a Multi Channel Lab Trough The unique design of this reagent reservoir was created through many years of product development manufacturing design and industry experience to be a durable and easy to use tool for the researcher Choose from four different sizes of the lab trough 15ml 25ml 50ml and 100ml in both sterile and non sterile packaging The sterilization process is by gamma irradiation which ensures the absence of growth affecting residue Lab troughs are HDPE White PS and Clear PET Multi channel lab trough is a state of the art tray developed by Quake Scientific Products gt Graduations on narrow side inner wall provide a quick reference for remaining solutions gt Unique rigid base design to help avoid spillage gt Pour spouts on all four corners gt Unique bottom trough design allows for complete removal of small volumes of solutions gt Sterile lab troughs packaged in easy open bags MODEL DESCRIPTION QTY PK MATERIAL Q100 550S 5ml Shorti Sterile Bulk Packaged 10 bag 50 PET Q100 550 5ml Shorti Non Sterile Bulk 50 PET Q200 550S 5ml Shorti Sterile Bulk Packaged 10 bag 50 PS Q200 550 5ml Shorti Non Sterile Bulk 50 PS Q300 550S 5ml Shorti Sterile Bulk Packaged 10 bag 50 HDPE Q300 550 5ml Shorti Non Sterile Bulk 50 HDPE Q100 15100S 15ml Sterile Bulk Packaged 5 bag 100 PET Q100 1550 15ml Non Sterile Bul
134. imals neonatal mice Flexible polyurethane sheath with smooth rounded tip 36 long can be made longer Outside diameter nominal 0 032 max at tip 0 04 Time constant 0 18 seconds Max temp 140 C May be sterilized by Gas ETO gluteraldehyde solution or autoclave MODEL DESCRIPTION RET 2 Rectal Probe for Rats 1 long 0 59 dia 0 125 tip dia RET 3 Rectal Probe for Mice 0 75 long 0 028 dia 0 065 tip dia RET 4 Rectal Probe for Very Small Animals Neonatal Mice RET 2 ISO Rectal Probe for Rats with isolated sensor RET 3 ISO Rectal Probe for Mice and Neonatal Rats with isolated sensor DSP 1 Disposable probe sheaths 1 000 pk Flexible Implantable Probes IT Series IT series flexible microprobes can be used for tissue implantation measurement of small volume liquid samples rectal temperatures in baby mice etc Totally sheathed in chemical resistant Teflon Quite rugged Max temp 150 C Isolated Type designates needle gauge Or one gauge smaller in thin wall MODEL DESCRIPTION IT 14 0 050 diameter constant 0 3 seconds 3 lead length IT 18 0 025 diameter constant 0 1 seconds 3 lead length IT 21 0 016 diameter constant 0 08 seconds 1 lead length IT 23 For ultra fast measurements and use on micro size specimens Sensor lead only 0 009 dia Tissue implantable with 23ga needle supplied Rather fragile Max temp 150 C Time constant 0 005 secs 3 lead Teflon coated isolated IT 1E IT 18 with
135. in handheld thermocouple measurements Self diagnostic recalibration takes place each time the meter is powered on Each time the user checks the calibration of MicroTherma against an external standard finding will be within spec no adjustments required Each MicroTherma includes a traceable cal a certificate with actual test data Although the precision thermocouples provide the best possible accuracy for interchangeable probes the Micro Therma also allows a system cal adjustment to offset any probe errors Choose probes from our broad line of type T thermocouples gt Accepts type T thermocouples gt 0 2 C meter accuracy gt Self calibrating circuitry gt Includes hold max and min functions switchable C or F MODEL DESCRIPTION TW2 193 Microtherma 2 Type T Thermometer TW2 205 Protective PVC Boot TW2 100 Small Attache Case fits 1 2 probes 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 29 Animal Rectal Probes Sf _ _ For fast intermittent measurements Smooth ball tio Stainless steel shaft The isolated sensor can be used with monitoring equipment where electrical interference from other electrodes may be present Reinforced strain relief for applications where probe is in more frequent use Smooth ball tip 1 long stainless steel shaft 0 059 dia 0 125 tip diameter 5 lead length Time constant 0 8 secs The RET 4 rectal probe is for very small an
136. ing chamber select number of test cycles press auto calibrate and run test Blood pressure systems allow user to measure from 1 to 200 animals at once or independently No other system on the market has this capability Settings allow user to control temperature test cycle cuff inflation and deflation rates cuff calibration and various test parameters with simple touch screen interface Data is copied to a USB flash drive for analysis System detects systolic diastolic mean heart rate and temperature System display actual real time pulse recordings and all the numerical values Warming chamber is an independent environment controlled through touch screen interface Heating plates and room temperature are not a factor Warm air is delivered to the housing by a small fan which generates a calming white noise resulting in consistent and accurate readings All units can be daisy chained up to 200 channels and controlled independently IITC Tail cuffs are the only tail cuffs that require an average temperature of 32 C for rats and 34 C for mice Cuff design consists of a photoelectric cell which is still the most accurate method for obtaining tail cuff blood pressure pulses Other systems may require extreme high temperatures to obtain pulse readings This is a known danger since these extreme temperatures can cause the obvious thermo stress and or death of test subject ial al i Os E System consist
137. inless Steel E 20033 High Density Mouse Lid 13 x 17 Stainless Steel E 20034 Large Lid 23 x 16 5 Stainless Steel E 20029 Lid Storage Bracket Wall mounted bracket holds up to four lids EP 1130 6 Hose with quick disconnect Induction Chamber Clear durable acrylic constructed induction chamber Fresh anesthetic gas from vaporizer or manifold enters a barbed fitting and is directed to the bottom of chamber scavenged gas exits the opposite fitting to waste gas site Routered top ensures perfect fit No corners facilitate easy proper cleaning Stainless steel false floor and 10 blue tubing provided Accepts tubing from 0 25 0 375 inner dimension MODEL DESCRIPTION IC6X4 Small Induction Chamber Inner Dimensions 5 25 W x 3 5 H e Overall Dimensions 7 W x 7 H IC8X8 Large Induction Chamber Inner Dimensions 7 5 W x 8 H e Overall Dimensions 10 W x 10 H Anesthesia Line CO2 Chamber The cleanest C0 induction chamber on the market gt For mice and rats gt Simple quick and easy to use gt Small foot print 9 diameter easy to Keep on bench gt Quick connect with valve closes when disconnected keeps CO2 in tube and chamber gt Door allows user to place animals in chamber without losing COz Provides for ultra quick animal induction gt tube easily connects to CO source gt Disposable bag liner animal feces and urine remain in bag with animal Chamber is al
138. ion MODEL DESCRIPTION Micro Iris Scissors SC150 Straight sharp points 4 101 6mm D SC151 Curved sharp points 4 101 6mm Micro Scissors SC152 Straight superfine blades 3 25 82 5mm SC153 Curved superfine blades 3 25 82 5mm SC154 Right Angle 4 90155 Left Angle 4 Premium Grade Micro Tissue Forceps FC145 Curved Tip 4 25 107 95mm FC146 Narrow Fine Tip 4 25 120mm FC147 Super Fine Tip 4 25 107 95mm Alm Retractor ubh Specifications comm Spread 2 75 cm Prongs 2 25 5 cm Depth 0 125 0 32cm MODEL DESCRIPTION ALM112 Alm Retractor Instrument Cases Biocon Extremely durable easy to open yet remains tightly shut when not in use MODEL DESCRIPTION CS7550 Holds up to 8 instruments in separate compartments CS7575 Holds up to 10 instruments in separate compartments Zippered Velveteen lined case with leather look vinyl exterior zips closed around three sides MODEL DESCRIPTION CS7700 Holds up to 12 instruments Visit us online at www braintreesci com 11 7231BRASCI_NOPRICE 12 13 12 11 34 AM Page 12 a Instruments Microsurgical Instrument Kit Includes gt DERF needle holder g grated jaws 4000 teeth 6i per square inch oe 4 75 121cm gt Iris scissors straight 4 10 2cm gt SWISS jeweler style forceps non magnetic stainless steel style 5 micro fine 4 375 11 2cm gt McPHERSON micro iris suturing forceps straight smooth p
139. it www braintreesci com for details and pricing 28 BRAINTREE SCIENTIFIC 781 348 0768 Thermalert Monitoring SHSrMOMere gt Large digital display Reads to 0 1 C in clinical range 25 45 C gt High stability no calibration necessary gt Safe low voltage battery operation gt Long battery life 1200 hours This economical easy to use thermometer is intended for continuous monitoring in the laboratory The digital display reads to 0 1 C For safety the unit is battery operated Batteries last for 1200 hours A variety of fast reading microprobes and special animal probes are available for the TH 5 TH 5 can be supplied with analog output for lab applications where strip chart recording is needed Specifications Temperature range 25 to 45 C Resolution 0 1 C Instrument accuracy 0 1 C 1 digit Calibration Conforms to National Bureau of Standards tables Monograph 125 Readout 0 5 liquid crystal Batteries 4 C cells Battery life 1200 hours continuous Analog output Available at extra cost Approx IOmV per C MODEL DESCRIPTION TH 5 Thermalert Monitoring Thermometer p TH 5A Thermalert Monitoring Thermometer with analog output TT S 5 Thermalert Stand MicroTherma 2T The MicroTherma 21 is compact easy to operate and reliable The popular MicroTherma Series makes use of a unique line of high precision type T thermocouples The combined result provides the best accuracy available
140. k 50 PET Q100 1550S 15ml Sterile Individually Wrapped 50 PET Q200 15100S 15ml Sterile Bulk Packaged 5 bag 100 PS Q200 1550 15ml Non Sterile Bulk 50 PS Q200 1550S 15ml Sterile Individually Wrapped 50 PS Q300 15100S 15ml Sterile Bulk Packaged 5 bag 100 HDPE Q300 1550 15ml Non Sterile Bulk 50 HDPE Q300 1550S 15ml Sterile Individually Wrapped 50 HDPE Q100 25100S 25ml Sterile Bulk Packaged 5 bag 100 PET Q100 2550 25ml Non Sterile Bulk 50 PET Q100 2550S 25ml Sterile Individually Wrapped 50 PET Q200 25100S 25ml Sterile Bulk Packaged 5 bag 100 PS Q200 2550 25ml Non Sterile Bulk 50 PS Q200 2550S 25ml Sterile Individually Wrapped 50 PS Q300 25100S 25ml Sterile Bulk Packaged 5 bag 100 HDPE Q300 2550 25ml Non Sterile Bulk 50 HDPE Q100 50100 50ml Non Sterile Bulk 100 PET Q100 50100S 50ml Sterile Individually Wrapped 100 PET Q100 50200S 50ml Sterile Bulk Packaged 5 bag 200 PET Q100 5050 50ml Non Sterile Bulk 50 PET Q100 5050S 50ml Sterile Individually Wrapped 50 PET Q200 50100 50ml Non Sterile Bulk 100 PS Q200 50100S 50ml Sterile Individually Wrapped 100 PS Q200 50200S 50ml Sterile Bulk Packaged 5 bag 200 PS Q200 5050 50ml Non Sterile Bulk 50 PS Q200 5050S 50ml Sterile Individually Wrapped 50 PS Q300 50100 50ml Non Sterile Bulk 100 HDPE Q300 50100S 50ml Sterile Individually Wrapped 100 HDPE Q300 50200S 50ml Sterile Bulk Packaged 5 bag 200 HDPE Q300 5050 50ml Non Sterile Bulk 90 HDPE Q300 5050S 50ml Sterile Individually Wrapped 50 HDPE Q100 100100 100ml Non St
141. ks of 1 000 P1000 200 R 200uL max case of 4 800 racked tips supplied in 5 packs containing 10 x 96 racks P1000 300 300uL pipette tips case of 10 000 tips supplied as 10 x bulk packs of 1 000 P1000 300 R 300uL pipette tips case of 4 800 racked tips supplied in 5 packs containing 10 x 96 racks Transfer Pipettes Single use Pasteur pipettes C Our range includes a large variety of transfer pipettes for safe and convenient application when transferring liquids in laboratories Disposable Pasteur pipettes are suited for versatile application without any risk of injury or infection from broken glass As single use products pipettes safely prevent carry over or cross contamination Practical graduations are ideally suited for sample measurement and transfer Pipettes can be heat sealed to store residual volumes For a sterile transfer of liquids our range includes sterile options either individually wrapped or 20 pipettes per pack Polyethylene material is environmentally neutral thereby ensuring non toxic disposal LENGTH BULB DROP TYPE MODEL DESCRIPTION VOL SIZE GRAD PIP 2020 5 Packs of 20 Pipettes 156mm 3 5m 30 45uL C 1 0 25ml Sterile PIP 2001 100 pieces individually wrapped 156mm 3 5m 30 45uL C 1 0 25ml Sterile PIP 1170 100 pieces Non Sterile 115mm imi 45 55uL G PIP 1180 100 pieces Non Sterile 104mm imi 17 22 uL H Additional pipettes available online Please visit www braintreesci com for details and pricin
142. l Rat Catheter Can be used as a return catheter to shunt the bile into the duodenum its tip is larger in diameter MRE040 MODEL DESCRIPTION R DUOD Duodenal Catheter MODEL Stereotaxic Brain Lesioning Cannula These stainless steel cannulae are designed to fit in slotted acrylic stereotaxic clamping devices and are ideal for administering chemical solutions to discrete areas of the rat and mouse brain gt Cannula consists of a 60mm length of 30ga stainless steel hypodermic tubing with a 45mm overlapping sleeve of 23ga stainless steel tubing to facilitate secure placement by the stereotaxic clamping device gt Tip of the cannula consists of exposed 30 gauge stainless steel hypodermic tubing 10mm long gt Cannula comes with an 18 length of Tygon tubing with an end designed to fit over a micro syringe needle tip MODEL DESCRIPTION RM SBL Stereotaxic brain lesioning cannula VAKU 8 Safety Blood Collection Set Infusion Set Quiet Needle motionless needle system and Safety Guard for user s protection Its unique design allows the needle to rest motionless when the back end is moved unlike other brands packaged in coils where the needle moves with the slightest movement of the back end VAKU 8 is packaged in convenient long thin packages that fit easily in lab coats and trays MODEL DESCRIPTION VACU8 21 21ga 8 L Tubing sterile VACU8 23 23ga 8 L Tubing sterile VACU8 25 25ga 8 L Tubing sterile
143. l clutter while providing superb control and feel Retractor wires can be used on their own to retract or manipulate tissue or fitted to provide a wide range of retractor styles Retractor wires engage and lock into the fixator jaws at the desired elevation allowing both linear and rotational adjustment over the entire length of the wire One end of the wire is formed in a loop to provide grip for a gloved hand and the business end is formed into a right angle hook that can retract on its own or lock to a range of retractor tips Can also be reformed to create restraints or engage other lab apparatus that need to be secured in the surgical field Wires are available in 10cm and 14cm lengths for mouse and rat procedures Retractor tip widths range from 1mm to 7 5mm plus a single point sharp tissue hook Each tip can be locked onto a wire for static retraction or affixed to an elastomer to form a dynamic retractor MODEL DESCRIPTION ACD 014 Small Animal Set Mouse ACD 015 Medium Animal Set Rat CIN a 7231BRASCI_NOPRICE 12 13 12 11 34 AM Page 13 P Surgery and Micro Tattooing Platform Can be used for surgery micro manipulations general micro utility platform i e organ inspections dissections etc gt Flex arm non obstructive rimless magnifying glass main lens 2 3 X inset lens 4 0 X gt Non skid feet for added stability gt Universal input power supply 100 240 VAC 50 60 Hz Surgery Platform
144. l tolerance is reduced and recovery is slow Studies of mammalian cell biology are conducted at 37 C in expensive incubators in order to maintain normal function However the manipulation of cultures in a clean hood or on the bench top almost always leads to significant cooling At the least this results in the displacement of growth curves At worst it can lead to significant cell mortality To maintain temperature during experimental procedures many methods are used Coverings help but are impractical during most procedures and cannot replace heat already lost Electrical heaters must be carefully monitored to prevent overheating or oscillation Electrical devices often interfere with recording equipment They are a shock hazard in the presence of urine blood or culture media and the spark of a thermostat might ignite a flammable anesthetic or solvent The Deltaphase Isothermal Pad is a unique approach to temperature stabilization It is a source of heat which cannot overheat once it enters its phase change It is economical in that it needs no tubes wires or electricity It is also safer than other devices because it needs no thermostat or controller and does not generate electrical signals But it can maintain a small animal or a culture bottle at near normal and constant temperature for several hours The concept of the Deltaphase Isothermal Pad is derived from the basic thermodynamic principle that a phase change occurs at cons
145. lat tilted it is 9 5 high Flat 30 48cm x 35 56cm x 13 65cm tilted 24 13cm high Heated work stand kit converts this work stand to a heated work stand MODEL DESCRIPTION RW A3467 Rodent Work Stand RW HHP Heated Pad Kit a Enrichment Products 27 Cocoon Nesting Fibers j i 4 _ gs Cocoon is the latest environmental enrichment nesting and bedding product for rodents Offers the animal an opportunity to fulfill their nesting instincts The fibers of the Cocoon product are very short which is safer for the animal and allows it to create a soft nest much like in its natural habitat Cocoon is whitened without chlorine Sold 6 000 cylinders per case MODEL DESCRIPTION UNITS COCO 087 Cocoon Nesting Fibers sa sis eve saeseeuw ens 6 000 cs 271 Refuge Mouse Hut A comfortable and quiet place to rest or to climb on and explore gt Material to shred just for fun or to build a nest usually last 7 to 30 days gt A W x 4 L x 2 5 H 3 openings gt Environmentally safe non toxic MODEL REFUGE 087 DESCRIPTION UNITS Refuge Mouse Hut amp ineu ed end eee ee we ae 1 000 cs Intubation ry BioLITE Stand Simple durable stand is easy to clean store and is portable Constructed from durable polycarbonate this platform provides the perfect stage for intubating mice and rats of all sizes The animal is suspended from the incisor wire on the angled side of the stand Three mounting positions are
146. latform 0 3mm x 5mm no teeth 3 5 8 9cm gt McPHERSON VANNAS micro iris scissors straight sharp points 3 25 8 3cm gt PlainWire eye speculum blades 15mm wide 2 5 6 4cm gt Probe double ended malleable sterling 4 5 11 4cm gt Storage cassette 6 5 x 6 25 x 1 25 gt Storage cassette mat yy an MODEL DESCRIPTION MSK 6890 Microsurgical Instrument Kit MSK 6890 NC Kit without Storage Cassette amp Mat Extensive selection of instruments available Please email info braintreesci com for details and pricing aoe Small Animal inaeadage System The small animal surgery system sets a new standard of procedural control The fully integrated procedural and stabilization system provides precisely controlled retraction at the operative site The CD Labs system allows researchers to operate independently eliminating at the need for an assistant or improvised assistive devices The system removes the complexities and distractions of improvised set ups allowing the researcher to focus full attention on the surgical procedure gt Eliminates the need for an assistant gt Reduces setup and procedure time gt Provides superior control gt Improves visualization Animal tables are made of ferro magnetic steel and incorporate a window for compatibility with body temperature maintenance systems Fixators hold retractors Contain rare earth magnets that attach anywhere on the animal table A push button t
147. led Mini Mortar and Pestle Set Shop online at www braintreesci com al so Visit us online at www braintreesci com 53 a 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page 54 Lab Equipment W BeadBug Microtube Homogenizer gt Extremely powerful mixing for lysis grinding or homogenization gt Faster and more effective than tissue grinders gt Mix 1 2 or 3 tubes simultaneously gt Extremely compact less than 7 wide gt Eliminates cross contamination associated with hand held homogenizers BeadBug is a high energy benchtop homogenizer that sets the performance standard for personal sized cell disruption and lysis instruments simultaneous homogenization of up to 3 samples takes place often within 45 seconds inside disposable 2ml screw cap microtubes Optimized mixing motion causes rapid cell disruption through constant high velocity impact from hardened micro beads chosen specifically for your sample type Developed for samples too tough to be homogenized in a common lab vortexer BeadBug provides a convenient and economical alternative to traditional homogenizers With up to three tube capacity and a foot print of just 7 x 8 BeadBug is the ideal homogenizing instrument for low to medium throughput laboratories Specifications Speed range 2 700 to 4 000rom Capacity 3 x 2ml screw cap non skirted Timer 3 sec to 3 min Operating temperature range 4 C to 65 C Dimensions 6 9
148. less steel operating surface lies in contact with an activated Deltaphase isothermal pad The underside of the pad is insulated to provide a longer isothermal period Molded wells are provided E iii oie uo sence geisior eter Space age thermal reflector for sponges instruments and anesthetic apparatus 2 hours of Thermo Regulation maximizes heat transfer This board was designed by research scientists to be functional durable e Wa a a and easy to clean Its low cost and safety make it appropriate for use in gt Two flexible LED lights provide direct illumination with no shadows Student laboratories The unit is supplied with two Deltaphase pads and no heat ee pad is 8 x Ti on 8 SUpp p p gt Thermo reflector and turbo heat sink to maximize heat transfer gt Flex arm non obstructive rimless magnifying glass 2 3 X main lens 4 0 X inset lens Allows continuous eye contact with object when moving into magnification area gt Limb restraints gt 4 Space Gels for continuous heat gt 2 Space Blankets to retain heat Rodent Work Stand gt Non skid feet for added stability gt Universal input power supply P gt Size 13 5 Lx 9 W MODEL DESCRIPTION ASS7T Thermo Control Surgery Platform with Space Gels SPGL S Space Gel Pad 4 x 6 SPGL L Space Gel Pad 5 5 x 10 SPDR Space Drape 12 x 6 2 drapes per pack ASS7D Thermo Control Surgery Platform with Deltaphase Pads DPIP Deltaphase Isothermal Pad 6 x 7 5 See microscop
149. lex 7mm Wound Closure System For those who prefer the smaller clip the Reflex 7mm Skin Closure System is the right choice F7 mae E miim sormam MODEL DESCRIPTION a RF7 APL Applier RF7 CS Case of 100 box O ORFZ RMV Remover RF7 KIT Includes applier remover and 100 clips ep Wound Closures na aa Wound Closing System The Autoclip Applier works like a staple gun to rapidly apply Autoclip closures The applier will hold 20 Autoclips which are held firm and ready for use by rustless beryllium copper springs Autoclips provide maximum holding force with minimal trauma There is no need for assistance to operate the applier or remover When the wound is healed clips are easily removed with the Autoclip Remover Stainless steel Autoclips are non pyrogenic and supplied non sterile but may be autoclaved Ideal for use with laboratory mice and rats MODEL DESCRIPTION ACS KIT Autoclip Starter Kit includes applier remover and 1 000 clips ACS APL Autoclip Applier ACS RMV Autoclip Remover ACS BX Autoclips 100 box ACS CS_ Autoclips 1 000 case Basic Sutures for Small Animal Surgery Non absorbable natural silk The softness of natural silk has been preserved in this high grade suture Spools MODEL SIZE MATERIAL LENGTH 103 S 7 0 Silk 100 yds 104 S 6 0 Silk 100 yds 106 S 5 0 Silk 100 yds 108 S 4 0 Silk 100 yds 110 S 3 0 Silk 100 yds 113 S 2 0 Silk 100 yds 116 S 0 Silk 100 yds 119 S 1 Silk
150. livery ports can also be configured for both mice and rats or any combination of the two MODEL DESCRIPTION SR ADS Standard Rodent Unit MR ADS Multi port Rodent Unit IN ar 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 75 Workstations Stainless Steel Mobile Workstation EZ 25000 Components shown sold separately Mobile workstations constructed of heavy duty stainless steel with locking casters can easily move to multiple locations Work surface of 3 5 x 2 Open side shelves accommodate up to 2 CO tanks and 2 02 tanks Below work surface is an open shelf and a 2 door locking cabinet system can be conveniently set up for maximum flexibility and mobility small Mobile Workstation integrates all E Z anesthesia components into one convenient mobile workstation Half the size of the EZ 25000 constructed of the same materials The top work surface measures 22 x 21 and comes with a locking cabinet and interior shelves EZ 27000 Components shown sold separately MODEL DESCRIPTION EZ 25000 Mobile Workstation EZ 27000 Small Mobile Workstation Anesthesia Pole Stand gt For portable transport of E Z Anesthesia systems with a minimal footprint gt Accommodates each of our three New Generation E Z Anesthesia systems gt Convenient slide on mounting gt Swivel top allows precise positioning gt Accommodates two E tanks gt Stable five wheel base gt Optional Mayo Tray for surgical t
151. ll the tools needed to safely and efficiently tattoo rodents AIMS tattooing techniques are performed on Kit includes unanesthetized animals and produce easy to read permanent ID s AIMS gt AIMS standard tattoo machine with calibrated needle tube tattoo pigments and supplies have been used in the industry for over 25 gt Micro controller with extended machine speed years and have been demonstrated to be safe and non toxic gt AIMS humane rapid mouse cup restraint system Tattoo identification is cost effective with an average disposable cost of gt Tail tattoo reading light about 2 per neonate and 5 per adult rodent gt Certified safe non toxic supplies and tattooing accessories gt 2428 concentrated black pigment for C57 and B6 mice gt The NEO 9 Neonate Tattooing System na PO P1 lor strat Can be used for neonate rodent tattooing when purchased with the neonate or tattooing PO P15 neonate rodents of any color strain accessory package Kit includes Neonate accessory package includes gt Micro Tattooing Platform with light 4x magnification skin prep holder and DC power supply gt Finger guards gt Neonate pigment gt Micro controller with HDUI power supply gt Foot pedal on off gt Preset speeds gt Ultra light tattoo machine gt Non skid machine platform with pigment holder gt Micro tattooing station light skin prep holder 4x magnification gt skin pre gt AIMS certified safe tattoo
152. lled water Approximately 20 30 minute treatment Nebulization does not require oxygen Includes gt Hospital grade Schuco air compressor gt Blue top medication nebulizer gt Plastic collar gt crush proof Oz tubing to air compressor gt White elbow hose connector MODEL DESCRIPTION NEB MED 9cc Medication Nebulizer Modified Pie Cage to accept aerosol delivery A Aerosol enters the PIE via tubing attached to the central core Core is open on the top and solid on the bottom s B Modified Mouse Pie Cage sold separately PIE rotates so mice can be placed in individual sections C Aerosol exits each PIE section through one 3mm hole in the center of the outer edge D Aerosol is distributed to each PIE section via five 3mm holes MODEL DESCRIPTION MPC AERO Mouse Aerosol Cage RPC 1 AERO Small Rat Aerosol Cage 41cm dia 6 75cm height RPC 2 AERO Large Rat Aerosol Cage 46cm dia 8cm height 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 23 Thermocare Intensive Care Units The Thermocare water jacketed warmer base is made of heavy gauge fire retardant plastic The UL and CSA approved heater maintains the temperature of the water accurately through resistance heating controlled thermostatically with a direct water contact sensor Creates a natural thermal convection current within the walls of the unit and the heat is radiated to ensure a constant sustainable temperature within a safe therapeut
153. ller breather is required Also available in composite plastic for MRI use Breather is supplied with two nosecone sizes customized for mice rats and other animals weighing up to 500 grams Tight fitting nosecones eliminate gas leakage and protect personnel from gas exposure Includes heating elements for maintaining animal temperature during procedures System includes gt EZ 150C Classic vaporizer unit gt EZ 103 Microflex mouse rat non rebreathing unit gt EZ 178 Mouse Rat sure seal induction chamber gt EZ 211 Mouse Rat thin line stainless steel heated surgical waterbed 10 L x 3 5 W x 1 H gt EZ 163 Induction chamber warmer gt EZ 200 Water heating circulation pump gt EZ 258 Charcoal filters 8 gt QO Regulator specify which Oxygen Regulator is required EZ 320 industrial CGA540 EZ 330 medical yoke fitting gt Mouse rat nosecones nosecone plugs charcoal filter stand and all connecting tubes MODEL DESCRIPTION EZ 7200 Microflex Small Animal Systems Multi Animal System Featuring the Multi Animal Breather for use with x ray MRI and PET imaging equipment Breather incorporates five ports that can accommodate five mice or three rats simultaneously from a single gas line Custom breathers can also j be made to integrate with existing a _ equipment Breather is supplied with five mouse nosecones and three rat nosecones Tight fitting nosecones eliminate gas leakage and protect personnel from
154. ly efficient light coupling into small core fiber optics resulting in intense illumination Without the optical system intensity of light output is insufficient to visualize anatomical features which is why other flashlight based fiber optic illuminators are not compatible with small core fiber optics Using a small core fiber optic as both the stylet and guide wire the FOS provides enough rigidity for applying mechanical force while remaining flexible enough to traverse convoluted paths Light can also be delivered through the stylet guide wire enabling the user to illuminate the discrete places in the oropharynx directly where needed As accessories to the illuminator and stylets i 3 endotracheal tubes and lung inflation bulbs have specific ie and provide feedback making them essential to any intubation procedure The endotracheal tubes are urethane based IV catheters that are softer and more flexible than PTFE based catheters minimizing the trauma associated with intubation Lung inflation bulbs provide a means for verifying correct intubation through direct visualization of chest distention which is more reliable than observing mirror fogging or abdominal breathing Also available as a Complete Kit CO Kit that includes all the BioLITE System products for mouse and both sizes of rat The BioLITE System is available in the following kits gt Large Rat Kit 200 grams LR Kit gt Small Rat Kit less than 200 grams SR Kit gt
155. m Features include infuse and withdraw holds syringes 60 cc and below Set a single pumping rate and or dispensing volume Program up to 41 pumping phases that change pumping rates set dispensing volumes insert pauses control and respond to external signals sound the buzzer Network control and monitor up to 100 pumps from one computer Dispensing accuracy of 1 Motor stall detection available in the BS 501 model Typically used in high pressure applications where there is a risk of exceeding the maximum force specified OEM Starter Kit Allows user to interactively communicate with the pump from a computer Foot Switch Allows user to start stop or trigger the next phase on syringe pump Attach to a BS 500 to allow stand alone operation Utilizes TTL logic port on syringe pump Higher flow rates available MODEL DESCRIPTION BS 500 OEM Syringe Pump BS 501 OEM Syringe Pump with Stahl Detection Includes an optical encoder that will detect and stop the motor during a Stahl OEM Starter OEM Starter Kit Includes power supply pump to PC network cable and user manual ADPT 2 Foot Switch k Shop online at www braintreesci com S BS 300 Just Infusion Syringe Pump Just the features that you want and none that you don t want to pay for ringe Pumps oe J oo amp tices ir gt Holds small or big syringes up to 60ml gt Pump continuously until user stops pump gt Infusion
156. microsrysichogical System mult arg GH 7231BRASCI_NOPRICE 12 13 12 11 32 AM Page 1 Micro Renathane Implantation Tubing Reduces the probability of intravascular thrombosis Polyurethane Catheter Tubing Braintree Scientific is proud to present a major advance in chronic catheter material In our opinion Micro Renathane is the most blood compatible tubing ever made For implantation studies in experimental animals this new tubing offers extended catheter life and reduces the probability of intravascular thrombosis The scanning electron micrographs approx 10 000X illustrate the dramatic difference between Renathane tubing and conventional vinyl tubing After use in hemodialysis Renathane showed significantly fewer surface deposits of platelets proteins trapped red cells and other blood elements than other tubings Medical Grade Plastics It is appropriate to clarify the definition of the phrases medical grade plastic and FDA approved plastic There is no approved medical grade plastic or resin Each individual supplier has his own criteria for what polymer and additive combinations constitute suitability for medical use similarly there is no FDA approved plastic or resin in the Code of Federal Regulations Food and Drugs Title 21 Part 121 the FDA has listed the additives allowable in plastics intended for food contact use In formulating a PVC compound for medical use the manufac
157. mm 100 BG 9925 15ga 3 1 2 8mm 100 BG 9927 15ga 3 9 2 8mm 100 18 BRAINTREE SCIENTIFIC 781 348 0768 These needles feature plastic luer hubs and silicone tips and can be easily formed to desired shape 100 sterile needles per box MODEL GAUGE LENGTH D 001 20G 1 5 Straight D 002 18G 2 Straight D 003 15G 3 Straight Dyets Powder Feeder Jar Setup gt Prevents tipping or moving of Dyets feeding jar gt 100 stainless steel for easy cleaning and durability gt Versatile design allows for placement in any cage corner gt Set contains jar lid follower and holder MODEL DESCRIPTION DYETS Dyets Powder Feeder Jar Setup Rodent Feeder Bar oe Ses XS gt Administer easily No special skills required and completely eliminates need for dangerous gavage procedure gt Reduce time Administer dose to 10 15 animals in 5 10 minutes gt Mix drugs directly to any available food matrix peanut butter yogurt cheese gt Confirm visually drug uptake by animals gt Work effortlessly with small or large groups of animals gt Animals adapt to a feeder bar fast and effortlessly gt Works for all rodents MODEL DESCRIPTION FD BAR Rodent Feeder Bar Bite Guard 7231BRASCI_NOPRICE 12 13 12 11 36 AM Page 19 W Rat Loft Perforated stainless steel platform that is bent to form a hook allowing loft to be hung from top lip of cage Easy to install and can be left in cage for cleaning Stainless s
158. mps to one catheter line Supplied sterile MODEL DESCRIPTION SIZE TUBE OD TUBEID MATERIAL Y 0189E0 Rat Catheter single outlet 4 5F 40mm 052 034 PE Y 0189E0 Rat Catheter double outlet 4 5F 40mm 039 023 PE Cath Loc HGS Heparin Glycerol Catheter Lock Solution The antithrombic characteristics of heparin plus the viscous nature of glycerol is combined in a solution to promote and extend the patency of vascular catheters Proven as the solution of choice in studies in catheterized animals ss Al Cath Loc HGS solution acts as a non toxic anticoagulant o lock solution for indwelling catheters This formulation is Cath Loches a the most widely used as a pre clinical catheter lock ps ee S Luo et al AALAS 2000 Comparison of Catheter Lock Solutions in Rats Not for human use animal research use only MODEL DESCRIPTION HGS Cath Loc HGS 10ml vial Cath Loc HD Heparin Dextrose Catheter Lock Solution Cath Loc HDS acts as a non toxic anticoagulant lock amma solution for indwelling catheters for pre clinical research E This is one of the most common formulations used as a A reliable pre clinical lock solution to maintain catheter SSAI patency in vascular catheters This solution used in both eae large and small animals combines the high viscosity of spn maama OP 50 dextrose with the anticoagulant activity of heparin to promote and extended implanted catheter patency The high osmolarity of dext
159. ms Meticulously engineered cages feature a unique funnel and cone design that effectively separates feces and urine into tubes outside the cage No urine washover and no chance for urine to enter the feces tube so separation is immediate and complete For untainted and reliable samples All cage parts and stands are autoclavable Replacement parts available gt Cover Large vented keeps animal securely in cage Can be removed for easy access to animal gt Upper Chamber Made of transparent PC Surface is smooth gnaw proof noiseless Cleans easily with warm soapy water or detergent solution gt Feeder Chamber Located outside cage Size discourages rodent from nesting or sleeping inside gt Feed Drawer PC drawer slides out for easy filling without disturbing animal Ideal for slurries liquids or powders Not designed for food in pellet form Rear portion helps to catch spilled food to prevent contamination of feces gt Feces Collection Tube Made of non wetting PMP Pellets roll down sides of funnel to be collected in tube Unlocks with single twist from outside of cage without disturbing animal gt Urine Collection Tube PMP Graduated in cubic centimeters Unlocks from outside cage without disturbing animal Can be cooled with an ice bath gt Lower Chamber PC Can be removed without disturbing animal Cleans with warm soapy water or detergent solution gt Stand SS stand or rack must be used with any rodent
160. n tethering is not required Cannulated animals are free to roam between procedures unrestrained and untethered wearing only the Quick Connect Harness Catheters are protected and ready to access quickly and cleanly whenever needed All user has to do is connect a syringe It s that easy Choose from two versions of harness elastomeric and cloth to suit all researchers Each i harness has 2 different pin sizes to fit a wide range dsn of indwelling catheters MODEL DESCRIPTION QCH 21 Quick Connect Luer Harness with 21G catheter connector QCH 23 Quick Connect Luer Harness with 23G catheter connector QCJA 23 Quick Connect Jacket Adaptor with 23G catheter connector QCJA 21 Quick Connect Jacket Adaptor with 21G Catheter Connector QJ 00 Rodent Jacket for Quick Connect Jacket Adaptor Extra Small 100 150g QJ 02 Rodent Jacket for Quick Connect Jacket Adaptor Small 150 250g QJ 03 Rodent Jacket for Quick Connect Jacket Adaptor Medium 250 350g QJ 04 Rodent Jacket for Quick Connect Jacket Adaptor Large 350 500g QJ 05 Rodent Jacket for Quick Connect Jacket Adaptor Extra Large 500 International and US patent 7 665 424 Collars Tethers and Slings W Standard Harness with Tether For researchers that do not wish to use Quick Connect harness a standard harness with tether is available Couple this with a single luer swivel for a complete ready to use infusion system MODEL DESCRIPTION SAH 12 Standard Harness with 12 t
161. n to standard parameters of time and temperature software also allows for successive time and temperature increments and decrements auto restart after a power failure end of cycling elongation steps and extended soaks at 4 C 100 programs each with up to nine segments can be stored in memory Units come standard with adjustable heated lid Lid features a slip gear to provide proper compression to prevent sample evaporation without deforming the tubes MODEL DESRIPTION TC020 24 MultiGene Mini with 24 x 0 2ml block TC050 18 MultiGene Mini with 18 x 0 5m block TC020 02 C 0 2ml tubes domed cap clear 1000 pk TC020 02 A 0 2ml tubes domed cap assorted colors 1000 pk TCO50 O05F C 0 5m tubes flat cap clear 1000 pk TCO50 05F A 0 5m tubes flat cap assorted colors 1000 pk MultiGene OptiMax Thermal Cycler The MultiGene OptiMax Thermal Cycler produces consistent reliable results while making gradient technology affordable This unit is extremely simple to program compact in design and built to perform Rapid heating and cooling of precision machined sample block is achieved by six Peltier modules Temperature sensors across the block feed data to the microprocessor to control operation of the system and ensure accuracy and uniformity Two types of temperature control are selectable gt Block control uses actual temperature of the block to adjust heating and cooling input gt Tube control uses a sophisticated algorit
162. nd easy to operate MODEL DESCRIPTION GPRU Gel Pad Activation Unit ep 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 27 Water Heated Hard Pads Connects to Gaymar Hamilton and other pumps i 4 4 ar We oe k A AN i ARERR Neat E og Sis i aati 3 eS AAS p lt A a ae h h an a 4 i j Y BA i f Durable polycarbonate construction Scalpel needle and towel clamp proof smooth surfaces are easy to clean helping to prevent nosocomial infection Highly puncture resistant MODEL DESCRIPTION HHP 05 6 W x 8 D Heated Hard Pad HHP 1 9 W x 12 D Heated Hard Pad HHP 2 15 W x 24 D Heated Hard Pad HHP 3 21 W x 24 D Heated Hard Pad HHP ADP G Adapter to connect to Gaymar Pump HHP ADP A Adapter to connect to Adroit Pump 27 Heated Work Stand Kit Heated hard pad kit converts user s workstand into a heated workstand Unit installs quite easily and can be ready for use in minutes with users existing or new Rodent Work Stand and circulating pump Unit is also designed to be used as a stand alone heated hard pad Product is a great versatile addition MODEL DESCRIPTION RW HHP Heated Rodent Work Stand Kit Rodent Work Stand Rodent Work Stand is designed to support rats mice and similar small rodents in a stable and comfortable position MODEL RW A3467 DESCRIPTION Rodent Work Stand a Temperature Control T Pump The T Pump system provides safe and 7 ef
163. nfuses and withdraws gt Accepts small syringes or large syringes up to 60cc gt Dispense continuously at a fixed pumping rate as low as 6uL hr or as high as 1200ml hr gt Change pumping rate and direction while pumping gt Selectable rate units uL hr uL mn ml hr ml mn gt Dispense a specified volume gt Dispense according to a pumping program to gt Pre program dispense volumes Each volume can be different gt Automatically change pumping rates or pumping direction gt Ramp up or down the pumping rate gt Timed delays between dispensers 62 BRAINTREE SCIENTIFIC 781 348 0768 a Easy to use keypad interface space saving chassis Foot print size of only 7 75 x 7 won t take up unnecessary space on laboratory or production bench gt Dispense and withdrawal pumping gt Dispense and withdrawal volumes separately accumulated gt Programmable dispense volumes gt Non volatile memory of all operating parameters and pumping program gt Programmable phases allow complex pumping applications and interaction with external devices RS 232 bi directional control gt Built in pump network driver Pump network supports up to 100 pumps and other devices gt Two modes of RS 232 control Basic and Safe Safe mode provides communication error detection loss of communication detection and automatic transmitting of alarm conditions gt TTL I O with software filtered control inputs to eliminate glitches and ringin
164. ng section having an ID OD of 0 023 0 037 MODEL DESCRIPTION M BTing Mouse Jugular Vein Catheter Total catheter length 65mm Intravascular tippet length 13mm External catheter length 10 15mm R BTing Rat Jugular Vein Catheter Total catheter length 115mm Intravascular tippet length 32mm External catheter length 25 30mm W intravenous Osmotic Pump Catheter M JVC AP R JVC AP Braintree Scientific s Micro Renathane based catheter for continuous intravenous via the jugular vein administration of drug solutions delivered with the ALZET Osmotic Pump Catheter can be modified for infusion via other blood vessels please inquire Supplied non sterile MODEL DESCRIPTION R JVC AP Rat Intravenous Osmotic Pump Catheter M JVC AP Mouse Intravenous Osmotic Pump Catheter 7231BRASCI_NOPRICE 12 13 12 11 33 AM Page 5 Polyurethane Rat Vascular Catheters Micro Renathane and RenaPulse gt Catheters consist of a continuous length of MREO37 or RPT037 with RenaSil suture anchors gt Catheters are accessed with Cat N 23 catheter needle gt Sealed with Cat 23 PP catheter plug gt No adhesives suture anchors grip the catheter tubing without constricting the catheter lumen and are movable gt Catheter tio rounding available for MREO37 catheter fabrications Rat Thoracic Catheters Rat jugular vein catheter specifications Total catheter length 120mm Port length 25mm Intravascular le
165. ng the operations are shown in meticulously accurate drawings thus making the manual an accurate instrument in comes close teaching and studying microsurgery and microsurgical techniques MODEL TITLE AR Anatomy of the Rat MODEL DINEE gt MICROSURG Manual of Microsurgery on the Laboratory Rat A Color Atlas of Sectional Anatomy by Takamasa Iwaki Hiroshi Yamashita Toshiyuki Hayakawa ee as Published in Japan September 2001 imeem 85 pages hardcover Ze ROOK Sate Available only from Braintree Scientific The Laboratory Animal Pocket Reference Series Basic information and common procedures are presented in detail for individuals performing research with below mentioned animals Guides include duties of animal facility management animal husbandry regulatory The mouse is the most widely used laboratory compliance and technical procedures As new books in this series become anormal OME Ci Were ares available we will add them to the list evaluation of the safety and effectiveness of new pharmaceutical products research in tumor The Laboratory Mouse suppression and vaccine and monoclinal antibody By Mark A Suckow University of Notre Dame Notre Dame Indiana USA proportional studies Peggy Danneman The Jackson Laboratory Bar Harbor Maine USA Cory Rats are used to research a wide field including preclinical tests Brayton Baylor College of Medicine Houston Texas USA microbiological research carcinogenic experimen
166. nge is easy to handle gt Noise level under 63 dBA at maximum speed gt Improved ventilation system keeps samples cool Distinct Control Panel gt Simple one handed operation gt Easy to program with gloves on gt Splash proof digital display gt Permanent indication of preset and actual values gt Selection of speed in both rom and g force with increments of 10 gt 10 acceleration and 10 deceleration rates possibility of unbraked My Fuge Mini Mini Centrifuge 3 g A gt Eight position microtube rotor gt Storage compartment for PCR rotor gt Near silent operation deceleration gt Starts and stops in just seconds gt Pre selection of running time from 10 seconds to 99 hours 59 minutes gt Conserves valuable bench space or continuous Specifications Speed 6 000 rpm 2 000 xg Dimensions 4 5 x 5 9 x 4 5 11 4cm x 15cm x 11cm gt Storage of up to 99 runs including rotor type gt Quick key for short runs gt Diagnostic program Specifications Maximum speed 13 500 rpm Maximum RCF 17 319 xg Capacity 8 x 1 5 2ml tubes 16 x 0 2ml PCR tubes 2 x 0 2ml PCR strips MyFUGE mini centrifuge is a personal centrifuge that fits in the palm of your hand Ideal for quick spin downs of microtubes and PCR tubes MyFuge is extremely easy to use Simply close lid and rotor instantly reaches 6 000 Maximum volume 4 x 100mL Speed range 200 13 500 rom Running time 59 min 50 seconds 10 seconds increments 99
167. ngth 32mm Number of retention beads 3 MODEL DESCRIPTION R JVC M37 MRE 037 Rat Jugular Vein Catheter R JVC R37 RPT 037 Rat Jugular Vein Catheter R JVC M37 R MRE 037 Tip rounding for Rat Jugular Vein Catheter Rat thoracic carotid artery specifications Total catheter length 120mm Port length 25mm Intravascular length 26mm Number of retention beads 3 MODEL DESCRIPTION R CAC M37 MRE 037 Rat Carotid Artery Catheter R CAC R37 RPT 037 Rat Carotid Artery Catheter R CAC M37 R MRE 037 Tip rounding for Rat Carotid Artery Catheter Rat femoral artery catheter specifications Total catheter length 230mm 210mm m or 190mm s Intravascular length 40mm Port length 25mm Number of retention beads 4 MODEL DESCRIPTION R FVC M37 MRE 037 Rat Femoral Artery Catheter R FVC R37 RPT 037 Rat Femoral Artery Catheter R FVC M37 R Tip rounding for Rat Femoral Artery Catheter Catheters W Mouse Intravascular Catheter Designed for quick and easy insertion into arteries and veins of mice and rats primarily mice Supplied sterile MODEL DESCRIPTION SIZE TIPOD TIPID MATERIAL MC 0189EO Mouse Catheter 28G 60mm 014 007 PU 32ga Mouse Catheter System This catheter system offers the smallest diameter catheter stylet product available for murine procedures 2G ethane _ oe s 010 f f i Flared to receive 27G needa f Transitional Sagmont 3 Appia Tation co
168. nsertion cone gt Formed white base housing batteries on off switch and lights gt Base acts as battery charging unit gt Electrical plug for recharging batteries 100 to 240 VAC capacity MODEL IRC 562 DESCRIPTION llluminated Rodent Tail Vein Unit includes 2 rechargeable batteries Tail Vein Injection Platform The quickest and easiest restraint for tail vein injections Simply pull mouse tail through the slot and make injection gt Non grip surface gt Wide opening for easy access gt Open slot for easy cleaning feces and urine easily washed away MODEL IL 300 DESCRIPTION Tail Vein Injection Platform Shop online at www braintreesci com Tail Snipping Platform or isolating DNA from transgenic animals for genotyping za simply pull mouse tail through the slot measure and collect tip in the vial gt Micro Tube Holder Collect tail tip directly in the prelabeled tube preventing DNA cross contamination gt Measuring Ruler mm Accurately measure tail length for cutting Enhances IACUC compliance gt Cleaning Slot Feces and urine are easily washed out with stream of water minimizes cross contamination MODEL DESCRIPTION IL 200 Tail Snipping Platform Bowman Style Rodent Restrainer The Bowman Style Rodent Restrainer has been re engineered and refined to accommodate larger sized animals up to 750 grams The positions of the Stainless steel rods around the rodent provide
169. ntreesci com or email info braintreesci com for details and pricing a Mixers and Shakers Revolver 360 Sample Mixer Superior sample mixing gt Complete 360 rotation gt Adjustable 0 90 mixing angle Accepts a variety of tube sizes and mixes them horizontally vertically or any position in between Changing mixing angle is easy simply turn rotisserie No tools required Revolver with optional H5600 15 rotisserie Interchangeable rotisseries accept tubes from 1 5m to 50ml Each rotisserie iS split into two halves Each half can be exchanged to mix more than one tube type at the same time Each half can be rotated independently from a center point on shaft Placing the halves in line with shaft produces an end over end tumbling motion similar to that used to mix blood tubes Rotating rotisserie at a right angle to the shaft produces a gentle mixing motion ideal for delicate samples Rotation speed is fixed at 18 rom Revolver with optional H5600 50 rotisserie Can be used in ambient temperatures from 4 C to 65 C Ideal for a variety of laboratory settings such as molecular biology biochemistry clinical and histochemistry Small enough to fit on a crowded bench the rotator is easily moved where it is needed Molded housing and unique rotisserie design makes the Revolver easy to clean and decontaminate 74 36 x 1 5 2ml rotisserie is supplied with Revolver Other configurations are available P MODEL
170. ogy using patented striking technology bullets in the Bullet Blender repeatedly strike tubes resulting in vigorous agitation of samples and collisions between samples and beads inside tubes gt High yields delivers high efficiency under microprocessor controlled conditions for consistent results Due to unique design minimal heat preserves sample quality gt High throughput runs up to 24 samples in parallel so work is done in a faster easier manner No probes to clean between samples so there is no cross contamination gt Best value more affordable due to a simple reliable design Standard tube compatibility Keeps operating costs low gt Choose from a variety of beads including RNase free covering a wide array of applications and samples packaged in bulk or pre loaded in tubes Bullet Blender comes with a starter pack sampling of beads Call for list Specifications Capacity Process up to 24 samples in 1 5 or 2ml tubes up to 12 samples in 5ml tubes or up to 8 samples in 50 ml tubes Tubes Uses commonly available tubes Environment Operational in constant 4 C to 50 C Use in refrigerator cold room or an incubator Air cooling option Keeps samples near ambient temperatures Speed control Adjustable to handle gentle vortexing to homogenization of bones Dimensions Most models have a small footprint 9 W x 10 D 22cm x 25cm Our largest model is 13 W x 14 D 33cm x 35cm SAMPLE TUBE MODEL DESCRIP
171. ools available call for pricing MODEL E 28000 DESCRIPTION Anesthesia Pole Stand n Table afi it Anti vibration table offers outstanding protection from vibrations for your balances Solid framed base can be leveled and has ample working space for accessing the balance Polished marble slab provides solid support and combined with specially designed rubber vibration reducing pads it makes for an anti vibration table that gives user the vibration relief needed for precision weighing The table comprises two separate parts gt An internal working surface consisting of a large marble slab mounted on adjustable rubber shock absorbing mounts gt An external service table with aluminium frame and adjustable a levelling feet Specifications Large working surface 15 8 x 17 7 Overall dimensions 31 5 x 23 6 x 30 8 Work surface dimensions 15 8 x 17 7 Weight of work surface 108 Ibs Total weight 170 Ibs gt Ergonomic styling for user comfort gt Rugged construction for durability gt Easy setup aluminum frame gt Adjustable leveling feet to compensate for uneven floors gt Scratch proof top slab to prevent surface damage MODEL DESCRIPTION AD VT Anti Vibration Table Visit our website at www braintreesci com Visit us online at www braintreesci com 75 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 76 Metabolic Cages Techniplast Metabolic Cage Syste
172. op operates multi level locking jaws that grip wire or elastomers firmly They can be adjusted linearly or rotationally with finger tip release Complete depression of the push button allows for insertion of the wire or elastomer while partial depression of the Surgical Tables and Boards 12 BRAINTREE SCIENTIFIC 781 348 0768 Rat Dissection Kit Includes gt Dumont forceps 5 gt Vannas scissors gt SuperCut iris scissors straight gt Alm retractor gt Needle holder gt Blunt probe gt Zippered case DESCRIPTION Rat Dissection Kit MODEL MDK R Mouse Dissection Kit Incudes gt Dumont forceps 5 gt Vannas scissors gt Dissecting scissors gt Wire retractor gt Needle holder gt Blunt probe gt Zippered case MODEL MDK M DESCRIPTION Mouse Dissection Kit push button allows for adjustment Fixators can also lock onto other lab components that require stabilization in the surgical setting such as neurological or rectal probes or anesthesia delivery systems The magnetic field is well controlled within the fixator to minimize interference with sensitive instrumentation In fact at a distance of just a few centimeters the effects of these small but powerful magnets are completely masked by earth s ever present magnet field Retractor wires are formed from light flexible stainless steel This simple approach produces an economical instrument that performs its job with minima
173. orithm Multiple syringe heater pads can be attached to the control unit gt Indicator on light Pump sold separately A calibration index is provided for infusion rates with different size syringes MODEL DESCRIPTION MODEL DESCRIPTION BS SYRH Syringe Heater Kit includes Control Unit BSP 1 0 01ml min duration 3 days power cable and Primary Syringe Heater pad BSP 2 01 ami e a draine she BS SYRH2 Syringe Heating Pad2 Kit for attaching a BSP 3 121ml nin E Gaines second heating pad to syringe heater kit BSP 4 0 04mi mi duan hie 4 Temperature sensed in primary heating pad only BSP 5 emi iain duration g mimis z BS SYRH3 Syringe Heating Pad3 for adding third up to sixteen heating pads Temperature sensed in primary heating pad only re SO enamin dralon ia 64 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 65 ch S Blood Pressure Measurement M Mouse Rat Tail Cuff Blood Pressure System Easy as 1 2 3 Configure one button calibration test ITC has designed a tail cuff blood pressure system in one compact unit Warming chamber tail cuff and restrainer completely controlled by the built in touch screen interface Requires no other external devices to deliver NIBP data at the touch of a button IITC tail cuff blood pressure system is unparalleled in ease of use place animal into supplied restrainer attach tail cuff set the desired temperature of the warm
174. ork under microscopes and other applications where a smaller breather is required Also available in plastic for MRI use System includes gt EZ 150C Classic vaporizer unit gt EZ 103A Microflex mouse rat non rebreathing device plus plastic surgery bed gt EZ 178 Mouse Rat sure seal induction chamber gt EZ 258 charcoal filters 8 gt QO regulator specify which Oxygen Regulator is required EZ 320 industrial CGA540 EZ 330 medical yoke fitting gt Mouse rat nosecones nosecone plugs 2 plastic surgery beds charcoal filter stand and all connecting tubes Single Animal System MODEL DESCRIPTION a EZ 7000 Small Animal Anesthesia Systems Single Animal System is designed as an economical alternative when a simple entry level system is sufficient Versaflex Small Animal System Accommodates animals ranging in size from neonate mice to rabbits Featuring the Versaflex Designed for treatment of one animal at a time Y splitter valve directs Breather anesthetic output to either induction chamber or breathing circuit Oxygen Versaflex breather offers the flush purges induction chamber before removing animal Carry handle flexibility to treat a wide range of facilitates safe easy transport of unit animals neonates up to 5 System includes kilogram rabbits Breather is gt EZ 108SA Single animal vaporizer unit supplied with three nosecone gt EZ 103A Microflex mouse rat non rebreathing device plus
175. ow Meter Offers precise liters per minute 2 16 LPM control of COz flow Flow meter ensures minimum gas usage and maximum safety for technicians Includes 6 hose and quick disconnect fitting that attaches to Euthanex Lid 72 BRAINTREE SCIENTIFIC 781 348 0768 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 73 Manifold Manifold supports multiple procedures while utilizing only one vaporizer While offering individual shut offs manifold provides intake of new gas to designated locations while opposite side provides output for used gases to a scavenger unit MODEL DESCRIPTION MAN 4 4 Station Manifold Additional sizes are available please call for a quote Euthanex Lids E 20029 Euthanex Lid system has become an industry standard Simply by removing the water bottle from the wire cage cover and placing Euthanex Lid over the host cage user is ready to perform euthanasia Eliminates the need to transfer animals Lids are available in five sizes to accommodate virtually all plastic cage sizes designed for small lab animals Heavy duty stainless steel lids have a Stem for easy connections to the regulator hose A foam lid gasket assures a good seal Multiple lids may be used to treat several cages at once MODEL DESCRIPTION E 20027 Super Small Lid 13 x 9 Stainless Steel E 20028 Small Lid 16 x 10 Stainless Steel E 20030 Square Lid 13 x 13 Stainless Steel E 20032 Medium Lid 20 5 x 11 Sta
176. oz 1 500 ml Approvals uL 2601 CSA C22 2 No 601 1 51DF gt Mercury free gt Uses tap water oO MODEL DESCRIPTION HTP 1500 Heat Therapy Pump 0 0 0 cece eee AP D22C single Patient Pad 15 X22 eee 20 case AP D26E single Patient Pad 18 X 26 6 eee 20 case AP D3E single Patient Pad 3 X 23 cee ees 20 case AP R22G Reusable Pad 15 xX 22 1 cee es 20 case Accessories rolling stand bed bracket and temperature flow rate tester available call for pricing Other models available online Please visit www braintreesci com for details and pricing Visit us online at www braintreesci com 27 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 28 Temperature Control TCAT 2 Temperature Controller Our new TCAT 2 general purpose PID autotuning controller provides accurate temperature control in a variety of laboratory applications Combined with a heat lamp or heating pad the TCAT 2 may be used to maintain the body temperature of anesthetized animals during surgery or stereotaxic procedures Small animal cages are easily warmed with a heat lamp The TCAT 2 may also be used in cooling applications such as to control independent perfusate cooling systems Realizing that laboratory applications are diverse TCAT Controller is provided in several versions The model specified depends upon whether a laboratory has a general or specific need for the controller MODEL DESCRIPT
177. pening lid By depressing lid button lid automatically opens allowing full access to samples Quick release rotors Prism Mini is supplied with two rotors An 8 place tube rotor accommodates 1 5 2ml tubes and a 4 place strip rotor accommodates 4 x 0 2mL tube strips or 32 individual PCR tubes Rotors both have a unique quick release hub design No tools are required to exchange the rotors simply snap off and snap on to change between applications Rapid braking Brake system is controlled electronically Once lid opens it signals the brake to activate so that the rotor will come to a quick and soft stop without disrupting the samples Specifications Capacity 8 place tube rotor and 4 place PCR strip rotor Maximum speed 6000 RPM Maximum RGF 2000 x G Dimensions 5 2 x 5 2 x 4 4 13 2cm x 13 2cm x 11 2cm MODEL DESCRIPTION QTY C1801 Prism Mini Centrifuge 120V each C1205 8 Adapters for 0 5 ml tubes pack of 8 C1206 8 Adapters for 0 4 ml tubes pack of 8 C1222 8 Adapters for 0 2 ml tubes pack of 8 Other models and capacities available online or by email Please visit www braintreesci com or email info braintreesci com for details and pricing Visit us online at www braintreesci com 43 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 39 AM Page 44 a Centrifuges Spectrafuge Mini Centrifuge two knobs Speed knob is used to set speed in either
178. pigment gt Fine a ie gt AIMS skin prep reduces fading gt Instruction book and DVD Micro Tattooing Platform gt Standard fine tip tattoo needles Laboratory Animal Tattoo Identification Vol 1 Neonate Mice and Rats gt Finger guards gt Needle scanning scope Large Lab Animal Tattoo System gt Comprehensive DVD instructions AIMS ATS 3L large lab animal tattoo system is a compact tattoo kit specifically gt Carrying case developed for tattoo identification of large laboratory animals hamsters gt Detailed training guide provides step by step guidance and detailed guinea pigs ferrets rabbits NHP swine anything larger than a mouse rat illustrations on multiple ID schemes with large number ranges gt 9 000 Kit includes Neonate tattoo identification is a practical and humane alternative to toe gt AIMS ultra light tattoo machine clipping non invasive Toe tattoos allow user to use existing numbering gt Foot pedal on off micro controller system without removing the toe Included supplies will tattoo 2000 gt AIMS small large bore calibrated needle tube neonates gt Select large animal tattoo needles For additional supplies visit braintreesci com gt Small equipment profile quick setup pickup gt Reduced animal stress quick tattooing gt Easy cleaning and sterilization between animals gt Detailed operating and tattooing instructions gt Unlimited technical support from AIMS 32 BRAINTREE SCIENTIFIC
179. plastic sizes customized for mice rats surgery bed rabbits and guinea pigs Tight fitting nosecones s eliminate gas leakage and gt EZ 178 mouse rat Sure Seal induction chamber protect personnel from gas exposure Includes heating elements for gt EZ 258 charcoal filters 8 maintaining animal temperature during procedures gt EZ 320 oxygen regulator for H tanks System includes gt Mouse rat nosecones nosecone plugs 2 plastic surgery beds charcoal gt EZ 150C Classic vaporizer unit filter stand and all connecting tubes gt EZ 104 Versalflex non rebreathing unit MODEL DESCRIPTION gt EZ 178 Mouse Rat Sure Seal induction chamber F7 SA800 Single Animal System gt EZ 212 Mouse Rat stainless steel heated surgical waterbed 10 L x 6 W x 1 5 H gt EZ 163 Induction chamber warmer gt EZ 200 Water heating circulation pump gt EZ 258 Charcoal filters 8 gt QO Regulator specify which Oxygen Regulator is required EZ 320 industrial CGA540 EZ 330 medical yoke fitting gt Mouse rat and rabbit guinea pig nosecones nosecone plugs charcoal filter stand and all connecting tubes MODEL DESCRIPTION EZ 7150 Versaflex Small Animal Anesthesia Systems 70 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 71 Microflex Small Animal System Featuring the Microflex Breather This low profile breather is suitable for work under microscopes and other applications where a sma
180. pring Spring applies Slight closing pressure to help hold tag in applicator prior to sealing MODEL DESCRIPTION EP 1005 S1 Stainless Steel Small Animal Ear Tag Applicator EP 1005 1 small Animal Ear Tags 1 000 pieces Custom numbering available Visit braintreesci com for details Ear Puncher A small and efficient ear puncher with spring action Allows user to come closer when marking animal and is also equipped with a sloped edge for a clean cut Autoclavable but should be lubricated afterwards for long and trouble free usage 11cm long with a 2mm diameter hole MODEL DESCRIPTION EP A7020 Ear Puncher HOLE DIAMETER 2mm Animal ID Systems Ear Punch Pincher These pinchers were developed after having several testimonies from customers with sore wrists and thumbs from using small ID punchers The Ear Punch Pincher relieves stress on wrist during ID marking as it requires a very gentle pressure to cut a hole Stainless steel puncher has a sloped edge which provides a cut rather than a punch which minimizes animal discomfort Autoclavable but should be lubricated afterwards for long and trouble free usage MODEL DESCRIPTION HOLE DIAMETER EP SA7000 Ear Punch Pincher 2mm EP SA7075 Ear Punch Pincher 2 5MM Aramis Micro tattoo System A revolutionary method for humane identification of laboratory animals Micro tattooing forceps with disposable hypodermic needle Individual identification is essential for
181. r 100 SYH 100 3 0 B00 B00 400u m 50 Z1 22 ST 1cc Zero Dead Volume syringe without connector 10 SYH 300 0 5 tcc 0 5cc 300u ml 100 SYH 300 1 0 tcc tcc 300u ml 100 SYH 300 2 0 3cc 2cc 300u ml 50 SYH 300 3 0 3cc 3cc 300u ml 50 SYH 500 0 5 tcc 0 5cc 500u ml 100 SYH 500 1 0 tcc tcc 500u ml 100 SYH 500 2 0 3cc 2cC 500u ml 50 SYH 500 3 0 3cc 3cc 500u ml 50 7231BRASCI_NOPRICE 12 13 12 11 33 AM Page 9 EZ Clip Ideal for use with lab animals or in veterinary surgery Racks of 9mm clips are individually packaged in heat sealed peel away Sleeves for cleanliness ease of handling and Storage EZ Clips are packaged 20 clips on a aitita rack with 5 racks per strip 100 clips total They A can be purchased by the strip 2 strips 200 clips or by the case 1000 clips Clips are pyrogen free and non sterile However the autoclavable plastic packaging allows for sterilization of the clips without removing them from the packaging The Clip Applier is a stainless steel applying forcep that holds one rack of 20 clips Works like a staple gun to apply clips to wound The clips are fed by rustless beryllium copper springs The Clip Remover is also stainless steel and can be used to remove all sizes of wound clips Autoclip and EZ Clip MODEL DESCRIPTION EZC KIT EZ Clip Kit EZC APL EZ Clip Applier EZC RMV EZ Clip Remover EZC SL EZ Clips Non Sterile 10 Racks 200 clips EZC CS EZ Clips Non Sterile Case 1 000 clips Ref
182. rainer specifically designed for tail vein injections Slotted tube permits the rat or mouse to be quickly pulled in by the tail The animal is then restrained by a plug which slides easily to accommodate any size rat or mouse but locks automatically when handle is released After dosing the handle is lifted and the plug is easily removed The Tailveiner is the fastest restrainer yet for intravenous injections in small animals MODEL DESCRIPTION TV 150 For Mice 1 25 ID Tube TV Small For Mice 1 125 ID Tube RTV 170 For Rats up to 120g RTV 180 For Rats up to 350g RTV 190 For Rats up to 500g Solid Brass Mouse Restrainer The Solid Brass Mouse Restrainer is designed to comfortably restrain a mouse for tail vein injections or sampling Specifications Size 2 x 4 Weight 2 lbs gt Able to warm for animal comfort and vasodilatation of the tail gt Solid brass maintains heat for extended periods gt Weight provides a stable and secure placement on lab bench gt Can be sterilized via autoclave ETO liquid VHP gt Long lasting MODEL DESCRIPTION SAI MBR Solid Brass Mouse Restrainer 16 BRAINTREE SCIENTIFIC 781 348 0768 a ECU Experimental Conditioning Unit Conditions rats and mice for long experiments ECU provides comfortable containment of experimental animals to facilitate repeated measurements of physiological and pharmacological parameters Not a restrainer animals are preconditioned trained
183. rature Control 271 Thermes Temperature Data Acquisition System Turns any PC into a precision thermometer gt to 7 channels gt 0 1 C stability and clinical accuracy gt 0 01 C resolution gt Reads up to 16 measurements per second gt Input isolation for low leakage gt Each unit accommodates up to seven type T thermocouple sensors gt Multiple Thermes units may be connected to the same computer for more thermocouple inputs gt High accuracy electronic cold junction compensation circuit maintains typical system accuracy of 0 2 C over an ambient temperature range of 15 35 C Individual offsets may be added to each input in software to facilitate individual calibration of each channel Thermes USB System gt USB system requires no internal connections to user s computer Simply connects via an external USB port on laptop or desktop computer Thermes WFI System gt Connect directly to a USB port from which it also draws power or wirelessly positioned up to 100 feet from host computer gt Includes secure USB 2 4GHz wireless receiver and wall mounting USB power supply gt May be operated remotely with BP 1 battery pack OPT 1 Optical Link gt 10 meter optical cable with built in transmitter and receiver allows Thermes USB to be operated in full optical isolation from host computer gt Medical grade isolated power supply is provided to power optical transmitter and Thermes data acquisition system when use
184. rcury thermometer clips onto gable cover for accurate temperature monitoring gt Exterior dimensions 14 x 11 x 13 36 x 28 x 32cm gt Interior dimensions 12 6 x 6 7 x 6 9 32 x 17 x 18cm gt Weight 17 lbs 7 7kg gt Chamber capacity 6 liter gt Temperature range ambient 5 C to 100 C MODEL DESCRIPTION W1106 Mini Water Bath 6 Liter with stainless steel gable cover and thermometer clip 115V W0020 110 Non toxic Teflon coated thermometer for 20 to 110 C with 1C resolution 305mm long 76mm immersion Other voltages available upon request Visit us online at www braintreesci com 25 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 37 AM Page 26 Warming Pads Thermo Controlled Surgery Platform Easily maintain animal body temperature during surgery Space age thermal reflector maximizes heat transfer Bottom holds two space gels for over 2 hours of Thermo Regulation gt Two flexible LED lights provide direct illumination with no shadows and no heat gt Flex arm non obstructive rimless magnifying glass 2 3 X main lens 4 0 X inset lens Allows continuous eye contact with object when moving into magnification area gt Limb restraints gt 4 Space Gels for continuous heat or 2 Deltaphase pads gt 2 Space Blankets to retain heat gt Thermo reflector and turbo heat sink to maximize heat transfer gt Non skid feet for added stability gt Universal input power supply
185. ris Scissors ON SSS 15 15 N SC130 SSS 20 20 f yN Q a 10 sterile scalpels per box 5 boxes per case Surgical Spears _ _ Ko Disposable super absorbent surgical spears for id use during ophthalmic and other microsurgical a procedures Available in cellulose and PVA For precise vascular and neurological dissection Ideal for small specimens 7 Supplied sterile 4 9 114 3mm MODEL DESCRIPTION MODEL DESCRIPTION SP 40400 PVA Surgical Spears SC128 Std Pattern Straight SP 40410 Cellulose Surgical Spear sC129 Std Pattern Curved 5 spears per pack 20 packs per box een a 10 BRAINTREE SCIENTIFIC 781 348 0768 IN ar 7231BRASCI_NOPRICE 12 13 12 11 34 AM Page 11 Dissection Scissors Metzenbaum Scissors Offering a unique combination of narrow blunted points along with thin delicate shafts for delicate dissection and minimal damage to surrounding tissues MODEL DESCRIPTION SC125 Curved Delicate 5 5 139 7mm SC126 Curved Delicate 7 177 8mm SC180 Curved Std Pattern 5 5 139 7mm SC182 Curved Std Pattern 7 177 8mm Forceps FC101 Fc108 FC037 FC038 FC027 FC028 FC009 _ FC127 FC128 FC109 FC110 FC102 Premium Grade Dressing Forceps serrated tips and ribbed grip to assist with delicate dissection Standard pattern serrated handle MODEL DESCRIPTION Standard Pattern serrated handles FC1001 Premium Grade 4 5 114 3mm FC1002 Premium
186. rolled vortexer useful for a maintain chosen parameters independent of load or voltage fluctuations os variety of molecular biology applications including Denaturation of DNA RNA Specifications and proteins lipid extractions reverse transcription yeast and bacteria Temperature range Ambient 5 to 100 C cultivation DNA plasmid isolation restriction digests gentle thawing of Temperature accuracy 0 5 C biological materials Speed range 200 1500 rpm Despite its modest 8 x11 footprint all popular tubes and plates are Motion orbit Horizontally circular 3mm compatible including as many as six 50ml tubes Speed time and Capacity 56 x 1 5 2ml tubes temperature settings are continuously visible on the LCD simultaneously Dimensions 8 9 x 12 3 x 8 9 22 5cm x 12 3cm x 22 5cm showing both actual and selected values Integral over temperature control MODEL DESCRIPTION ensures long life safety and sample integrity S2056A Vorlemp 56 Incubator Shaker complete with microtube MODEL DESCRIPTION and microplate platforms l l l l S2056 R Additional tube rack workstation H5000 HC MultiTherm Shaker with heating and cooling C1205 Individual adapters for 0 5 0 6ml tubes pack of 6 H5000 H MultiTherm Shaker with heating only C1206 Individual adapters for 0 4ml tubes pack of 6 Blocks separately C1222 Individual adapters for 0 2ml tubes pack of 6 H5000 02 Block 96 x 0 2ml or one PCR plate S2056 Q Extra microplate platform for Vortemp 56 H5000 05
187. roller with autotuning feature and feedback sensor breakage alarm gt Adjustable feet provide convenient viewing angle for display Technical Features gt Temperature control to within 0 5 C in the range of 40 C to ambient gt Thaw switch to quickly release frozen samples MODEL DESCRIPTION BFS 40MP Temperatue Controlled Freezing Stage IN ar 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 31 Infrared Thermometer Contactless IR temperature measurement for small rodents The IR B153 thermometer was designed to measure cutaneous temperature of small rodents very fast and contactless IR B153 thermometer focuses on optical dimension and the position of IR sensor in order to allow measurements on very small surfaces without allowing the sensor to get wrong values with integration of environment temperature which can occur with other industrial type infrared thermometers Allows easy measurements even on mice tails with high accuracy and repeatability The cutaneous measurement should be correlated with usual rectal temperatures See RET 2 and 3 rectal probes for rodents The IR B153 thermometer is especially accurate on a temperature range from 25 40 C and will prove to be useful for other lab applications as well Infrared temperature and guidelines Infrared temperature measurement consists in the detection of the quantity of light emitted by the measured object the optical signal received by the
188. rose prevents bacterial colonization and multiplication and the high viscosity of dextrose reduces washout from the catheter tip The heparin in the solution also aids in prevention of clot formation Since both dextrose and heparin are physiological constituents which occur naturally in the blood any excess Cath Lock HDS injected is quickly metabolized when used properly Available in 10ml sterile vials MODEL DESCRIPTION HDS Cath Loc HD 10ml vial Visit us online at www braintreesci com 7 LD ar 7231BRASCI_NOPRICE 12 13 12 11 33 AM Page 8 P Catheters Prefilled Syringes Prefilled syringes for flushing locking or sampling through any catheter or port system Order what you need when you need it in convenient ready to use packaging Syringe sizes range from 1cc 60cc with volumes from 0 2ml 60ml gt Forget ordering and storing saline and other physiologic solutions in large inconvenient containers gt Forget wasting time unwrapping countless individually wrapped syringes for your daily procedures gt Forget mixing sterile solutions and filling them in a less than Sterile environment gt Catheter patency issues that arise two weeks after surgery or longer Blunt Needles with Syring Attached blunt needles on o F amp 1cc syringes not only save a a tremendous amounts of time but will also help lower costs Additional size syringes are available and can be supplied with any size blunt needle All syringe
189. ry heat Cap material Polypropylene 140 C Please replace X with B for blue G for green P for purple Y for yellow W for white or AS for assorted caps 2 of each color MODEL DESCRIPTION B3000 50 X Bottle 50ml GL32 10 pk B3000 100 X Bottle 100m GL45 10 pk B3000 500 X Bottle 500m GL45 10 pk B3000 1000 X Bottle 1000ml GL45 10 pk B3000 2000 X Bottle 2000ml GL45 5 pk B3000 SP X Bottle StarterPack GL45 pack of 10 bottles includes 2x100ml 3x250ml 3x500ml and 2x1L for storage of reagents culture media 70 to 500 C permitting repeated use in freezers microwaves autoclaves Specifications Cap colors Standard blue green purple yellow white assorted B3000 250 X Bottle 250ml GL45 10 pk Replacement cap GL45 10 pk B3000 CAP X B3000 RIN Replacement sealing ring GL45 10 pk B3000 CAP2 Replacement cap blue GL32 10 pk B3000 RIN2 Replacement sealing ring GL32 10 pk B3000 CAP R High Temperature Cap red up to 180 C 10 pk 50ml bottles are only supplied with GL32 sealing caps Stainin Coplin Staining Jar 5 10 Slide Unit with Screw Cap Used for staining slides or as a developing chamber for r thin layer chromatography Holds five single 3 x 1 75mm x 25mm slides vertically or 10 slides back to I back Screw cap is made of linerless white polypropylene lit to reduce solvent evaporation Rectangular base holds l approximately 60ml
190. s Labnet BioFree pipette pips are designed to fit a wide variety of single and multi channel pipettes Flexible walls and a series of internal sealing rings ensure a secure fit and minimal force to eject a Pipettes Tips are manufactured from high quality FDA compliant polypropylene in a clean room environment Diamond polished stainless steel molds produce a tip with exceptionally smooth surfaces and extreme accuracy During manufacturing process each lot of tips is tested for accuracy and precision Tips are also carefully inspected for uniformity and manufacturing irregularities MODEL DESCRIPTION P1000 10 0 5 10uL pipette tips case of 20 000 tips supplied in 20 x bulk packs of 1 000 P1000 1000 1000uL pipette tips case of 5 000 tips supplied in 5 x bulk packs of 1 000 1000uL pipette tips case of 5 000 racked tips supplied in 5 packs containing 10 x 100 racks P1000 1000 R P1000 10 R 0 5 10uL pipette tips case of 4 800 racked tips supplied in 5 packs containing 10 x 96 racks P1000 10X 0 5 10uL pipette tips extended length case of 20 000 tips Supplied in 20 bulk packs x 1 000 P1000 10X R 0 5 10uL pipette tips extended length case of 19 200 racked tips Supplied in 20 packs containing 10 x 96 racks 1200uL pipette tips case of 2 880 racked tips supplied in 3 packs containing 10 x 96 racks P1000 1200 R P1000 200 200uL pipette tips case of 20 000 tips supplied in 20 x bulk pac
191. s a robust support that does not move Stainless supports and connectors held with convenient thumbs screws allow for height adjustments Frame is easily cleaned and dismantles when not in use Restraints Full body restraint is provided with choice of either sling suit or sling cover Both restrainers allow for access to all limbs head and tail Velcro fasteners allow for quick and secure restraint and adjustable fit for individual animals Sling suits are sold in five sizes according to weight range of animals Rodent Sling Cover is available in single size for rats up to 500g Custom sizes available on request MODEL DESCRIPTION RF S1 Rodent Sling frame and cover RF C01 Rodent Sling Cover only RS FC1 Rat Sling Suit Small 150 200g RS FC2 Rat Sling Suit Medium 250 350g RS FC3 Rat Sling Suit Large 350 5009 RS FC4 Rat Sling Suit X Large 500g Rodent Jackets Manufactured from breathable latex free power net mesh in a saddle style format Designed for use with rodent tethers and available in a range of sizes to ensure a secure yet comfortable fit MODEL DESCRIPTION MJ 00 Mouse RJ S Rat 150 2509 RJ M Rat 250 3509 RJ L Rat 350 500g 60 BRAINTREE SCIENTIFIC 781 348 0768 a Elizabethan Collars Designed to prevent animals from grooming and to protect surgical or treatment sites All collars are manufactured from a P low density polyethylene for smaller animals a lightweight material is used Collars close
192. s a a ek ed S 3 900203 Dish and COVED dcadeivnded deweadedun ded dan 3 900204 Glass Slide Rack ts0d20008005 08 adsense eas oni 3 900205 Handle naaa aa 6 Staining Dish 16 40 Slide Unit Mix and match components offer great flexibility Accommodates 16 20 and 30 slide racks Holds slides sizes ay Oo 1 POM M a 10 C J a 75mm x 38mm and 3 x 2 Lo 7omm x 51mm MODEL DESCRIPTION QTY CASE Approximate inside dimensions 118mm L x 88mm W x 70mm D 900303 Dish and COVED incececunded dtaeaeein wedded nnd 6 900301 DiGi seas owes teed dana eee eee es eee 3 900302 COVEI apai ai aden ie a ete aang abd rics eo alate 34 3 900234 30 Slide Rack with hinged handle stainless steel 3 900254 16 32 Slide Rack Glass iciiavid cava dadvvav ens 3 900304 20 40 Slide Rack Glass vas cseks tower eves ve 3 Staining Dish 50 Slide Unit Slotted rack holds 50 slides sizes 3 x 1 7omm x 25mm 3 x 1 1 2 75mm x 38mm and 3 x 2 75mm x 51mm Made of non tarnishable stainless steel that is resistant to staining solutions Handle is permanently attached but hinged to permit closure of the dish and easy insertion and removal of the microscope slides MODEL DESCRIPTION QTY CASE Approximate inside dimensions 185mm L x 88mm W x 68mm D 900400 Complete Dish Cover Rack Handle 6 900401 DISD se meteor cry its eco ae eT e w ae ae ee rene 3 900402 O E E eens 3 900403 Dish and Cover naaa 3 900404 50 Sl
193. s a stainless C1205 Individual adapters for 0 5 0 6ml tubes pack of 6 Steel pin for durability Small footprint allows Spectrafuge Mini Centrifuge to oe ata seer z EE ah en 6 rni ndividual adapters for 0 2ml thermal cycling tubes pack of 6 fit on even the most crowded bench making it a truly personal unit C2400 S StripSpin adapter for 0 2m tubes and strips gt The Spectrafuge Mini Centrifuge comes complete with microtube rotor strip Snaps onto standard rotor tube rotor adapters for 0 5ml and 0 4ml tubes Available in five different translucent lid colors MPS 1000 Mini Plate Spinner Specifications gt Quickly Spin down droplets Capacity 6 x 1 5 2ml tubes 2 x 0 2ml strip tubes and condensation Max speed g force 6000 rom 2000 x g Dimensions 6 x 6 x 4 5 153mm x 153mm x 102mm gt Use before and after thermal cycling to MODEL DESCRIPTION increase PCR yield C 1301 S Spectrafuge Mini with 1 5 2ml rotor strip tube rotor 0 5 and 0 4ml adapters smoke gray lid gt Accepts skirted non C 1301 B Spectrafuge Mini with 1 5 2ml rotor strip tube rotor skirted and all standard 0 5 and 0 4ml adapters blue lid PCR ol C 1301 T spectrafuge Mini with 1 5 2ml rotor strip tube rotor CR plates 0 5 and 0 4ml adapters teal lid gt Less than 1 4 the size of C 1301 P Spectrafuge Mini with 1 5 2ml rotor strip tube rotor most plate centrifuges 0 5 and 0 4m adapters purple lid a oat C 1301 R Spectrafuge Mini with 1 5 2ml rotor
194. s are capped and ETO exposed Call for additional sizes 8 BRAINTREE SCIENTIFIC 781 348 0768 FF 3 Po y h ra l a mmi wi is ay ae j z a oe H a Si i iN ip Moan ii L r ss j i m a _ Ss nd ii N AN g AN soak Ma are most likely caused by poor maintenance procedures and not related MODEL SIZE GAUGE LENGTH QTY PK to surgery B20 50 1 tcc 20 0 5 25 Prefilled syringes can be filled with most any solution including saline B20 100 1 dcc 20 1 25 apt B22 50 1 tec 22 0 5 25 heparin saline dextrose heparin dextrose and many others B09 100 1 i 09 1 25 MODE SYRINGE SIZE FILL VOL HEPARIN UNITS CS B23 50 1 tec 23 0 5 25 Saline 0 9 Filled Syringe B23 100 1 tec 23 o 29 SYS 1 0 5 1cc 0 5cc 7 100 B25 00 1 tec 29 0 9 20 SYS 1 1 0 1c 1c 100 B25 100 1 tec 20 l 29 SYS 3 2 0 3cc 2cC 50 SYS 3 3 0 3ce 3ce 50 Zero Dead Volume Sterile Syringes SYS 5 3 0 5CC Se 50 SYS 5 5 0 5CC a6 50 SYS 10 10 0 10cc 10cc 30 SYS 60 60 0 60cc 60cc 10 Heparin amp Saline Filled Syringes d oe oe ie se ae a Zero Dead Volume sterile syringes offer researcher the ability to completely cpg SYH 50 2 0 e oce 50u mI 50 remove all fluid from the syringe for zero test article of blood loss SYH 50 3 0 3c 3cc 50u ml 50 MODEL DESCRIPTION UNITS PK ae Ar La 71 22 PK 14cc Zero Dead Volume syringe with 22G connector 25 YH 40 a 0 ni re 10 a i 50 Z1 22 CS_ 1cc Zero Dead Volume syringe with 22G connecto
195. s of gt Amplifier gt Cuff inflation gt Warming chamber gt Touch screen control of all parameters gt Auto calibration inflation deflation rates tests per animal gt Automatic real time inflation deflation screen gt True pulse recordings shown not x y access gt Tail cuff gt Restrainers gt Spare parts package of all consumable items Mouse and Rat Blood Pressure System complete for 1 animal with data acquistion software automatic detection data collection complete touch screen control MODEL DESCRIPTION SENSOR SIZE MRBP M01 1 4 84 Adult Mouse Restrainer and Neonate Rats 20 80g 0 25 MRBP M01 1 4 84XL Mouse Restrainer 25 70g 20 80g 0 25 MRBP R0O1 3 8 83 MRBP RO1 7 16 81 MRBP RO1 7 16 82 MRBP RO1 3 4 82 MRBP RO1 3 4 79 Rat Restrainer 70 1709 Rat Restrainer 180 270g Rat Restrainer 250 400g Rat Restrainer 400 600g Rat Restrainer 600 800g MRBP RO1 1 79 Rat Restrainer 600 800g 650 800g 1 MRBP RO1 1 78 Rat Restrainer 750 1000g 650 800g 1 Note The 600 800g restrainer can work in conjunction with either the 0 75 or 1 sensor this depends on the thickness of the tail MRI Option Add 100 to the cost of the system and MRI at the end of the model number 70 160g 0 375 150 380g 0 437 150 380g 0 437 900 6509 0 75 900 650g 0 75 Shop online at www braintreesci com Visit us online at www braintreesci com 65 CIN ar 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 66
196. s safe sealing features MODEL DESCRIPTION UNITS MICROVETTE 100 100pL Conical inner tube MCB 201280 BX Serum cee 100 pk MCB 201280 CS Serum ccc cece eee ees 1 000 cs MCB 201282 BX _Lithium Heparin 0 00 0 100 pk MCB 201282 CS _Lithium Heparin 0 0 0 1 000 cs MICROVETTE 100 100uL Round bottom inner tube MCB 201278 BX Potassium EDTA nnna 0 00 0 c ee eee 100 pk MCB 201278 CS Potassium EDTA onnaa 0 0 00 1 000 cs MICROVETTE CB200 200uL Conical inner tube MCB 201290 BX SEMUM cc ee ees 100 pk MGB 201290 GS SGM 240204 caves naw ese eenvewes 1 000 cs MCB 201292 BX _Lithium Heparin 00008 100 pk MCB 201292 CS _Lithium Heparin 0 0 00 1 000 cs MCB 201289 BX Glucose kandi vewsdaas wade a wows de 100 pk MCB 201289 CS GluCOSe 2 cece ees 1 000 cs MICROVETTE CB200 200uL Round bottom inner tube MCB 201291 BX Serum Gel 0 00 cece ee 100 pk MCB 201291 CS Serum Gel 0 0 cc cee ees 1 000 cs MCB 201288 BX Potassium EDTA 00 0 e eee 100 pk MCB 201288 CS Potassium EDTA 0 0 00 e eee 1 000 cs Microvette CB 300 Capillary collection and sample container in one unit The Microvette CB 300 capillary tube along with its attached push cap is supplied complete with a carrier tube that is also suited for transport and centrifugation Cylindrical outer tube is ideal for attachment of a barcode label for direct sample analysis
197. sample containers to make the Orbit 300 a truly multipurpose shaker Flat platform covered with a nonslip rubber mat holds plates dishes boxes etc Microplate platform will accommodate up to four microplates Remaining platform has spring loaded retaining bars that adjust to hold flasks bottles racks and other containers in place Time and speed are set and displayed digitally Values are shown on the large three digit LED Broad speed range allows the Orbit 300 to be used for gentle mixing as well as vigorous agitation shaker housing is constructed of heavy gauge coated steel to reduce motor noise and lend stability to the unit Compact shaker can be used in temperature controlled environments making it ideal for cold room or incubator use Specifications Speed range 100 1200 rom Timer 0 to 99 minutes or continuous Motion orbit size horizontally circular 3mm Maximum load 12 3 b 5 6 kg Ambient operating range 4 to 65 C MODEL DESCRIPTION S 2030 300 Orbit 300 Digital Multipurpose Shaker base only S 2030 10 Platform for four microplates 5 2030 12 Flat platform 30 x 30cm with nonslip rubber mat S 2030 13 Spring loaded platform for flasks bottles etc Other models and capacities available online or by email Please visit www braintreesci com or email info braintreesci com for details and pricing Mixers and Shakers Orbi Shaker gt Perfectly circular 19mm orbit for aeration and mixing gt Digit
198. sensor bead exposed Combines the ultra fast response of IT 23 with the Teflon sheath strength of IT 18 Time constant 0 005 seconds isolated Probe Wipes J Effective against a wide range of bacteria including listeria and salmonella Each wipe is pre saturated with a broad spectrum anti bacterial solution that is odorless and does not taint food Single sachets are handy to carry and can be used by simply puncturing with your probe and running it back and forth Mini tubs easily fit in a pocket or drawer Large tubs are economical and can be mounted close to the point of usage i MODEL DESCRIPTION 836 200 Sachet 6 x 7 5 wipe carton of 100 wipes 836 022 Mini Tub 2 75 x 5 wipe single tub of 70 wipes 836 052 Large Tub 5 x 5 wipe single tub of 200 wipes eP Temperature Control 27 Wessels Induction Warming Chamber Provides continuous heat to animals being anaesthetized before surgery or recovering from surgery gt Quick warm up time gt Precision temp control gt Easy cleaning gt 10 minute set up time 1 Connect chamber to VE 100 controller 2 Select cage plate temperature 102 F 39 C 3 Confirm cage plate temp with IR thermometer 4 Place animal in chamber and monitor VE 100 Precision Temp Controller Allows user to set a precise cage plate temperature based on current laboratory conditions room temp etc Filter Top Allows animal to fully recover in chamber while unattended In
199. sensor being then converted into an electrical signal Instruments are equipped with a lens to concentrate the light on the sensor This lense has different characteristics according to the object user wants to measure diameter focal length viewing angle or distance ratio between the surface seen by lens and distance to the object User should also take into account the emissivity or amount of emitted light of the measured object The focal specifications of typical general thermometers usually allow the measurement of objects from a minimum distance of 10 25mm with a minimum target size of 15mm and a distance ratio of 1 10 emissivity is generally fixed to 0 95 Such thermometers are unable to measure from lt 10mm from the object and this measurement includes all points in a circle of 15mm of diameter If object is situated 50cm away the surface of measurement will have a diameter of 5cm These dimensions are fully inadequate for cutaneous temperature measurements in rodents which is why IR B153 is ideal for these procedures Important notice Measurement taken in animal fur may include ambient air caught in hair thus creating important measurement variations It is therefore advisable to measure on naked surfaces like skin tail nose genital area Specifications Room temperature 15 25 C Global measurement range 20 C 200 C Resolution 0 1 C Distance ratio 1 1 5 Accuracy 0 3 C from 25 40 C Minimum distance
200. sit us online at www braintreesci com 9 a 7231BRASCI_NOPRICE 12 13 12 11 34 AM Page 10 a Instruments W NSET Non Surgical Embryo Disposable Stainless Steel Transfer Device Safety Scalpel Se Engineered for safety and simplicity Mbt 27 BE Complies with the OSHA directive lo pecans Yee by providing a fully retractable a N scalpel blade which protects the ee user from accidental needle sticks associated with traditional scalpels Reusable sterile stainless dissecting surgical blades and handles also available call for size and pricing S B Supplied sterile Single use Paralechs Corporation has revolutionized embryo transfer in mice with MODEL SIZE the NSET non surgical embryo transfer device for mice NSET allows mag pm non surgical embryo transfer for production of research transgenic or 4 511 11 knock out mice NSET is a major refinement of murine embryo transfer 4 515 15 as it eliminates pain and stress of surgery and anesthesia MODEL DESCRIPTION aTY Scissors NSET Non Surgical Embryo Transfer Device 005 10 bx SuperCut Scissors Technocut Plus Di sposabl e Manufactured with the highest grade surgical stainless steel Tempered and hardened for a longer sharper life The SuperCut blade has a specially Safety Scalpels designed razor sharp edge The safety and performance you need Tungsten Carbide Scissors 7 1 aS Unique tungsten carbide cutting edges provide ef
201. ssary for immediate utilization is a vaporizer for the agent of your choice Frees user from the restraints of the operating room to work on bench top when appropriate MODEL DESCRIPTION AWS Anesthesia Workstation Visit us online at www braintreesci com 73 7231BRASCI_NOPRICE 12 13 12 11 43 AM Page 74 Anesthesia Line Vaporizers ay Calibrated 0 25 to 5 using a laser refractometer for the specified anesthetic drug Complete with safety lock to help prevent accidental turn on of dial Fluctuations in temperature flow rate and duration of use is automatically compensated for during use When used with P P V the variation in output is negligible Please specify drug type Isoflurane Halothane Sevoflurane Enflurane Add an additional 100 if purchasing for Sevoflurane Drug not included MODEL DESCRIPTION VP Cage Mounting and Well Fill iy A i Single Animal Vaporizer Unit An economical choice for single animal treatment DESCRIPTION single Animal Vaporizer Unit MODEL EZ 108SA Classic vaporizer Unit Unit incorporates a manual five output manifold iN that includes a new flowmeter configuration that improves upon the original E Z Anesthesia design DESCRIPTION Classic Vaporizer Unit MODEL EZ 150C mute Flow Vaporizer Unit s Featuring an automatic five output manifold that F does not require flowmeters DESCRIPTION Auto Flow Vaporizer Unit MODEL EZ 190F
202. tanks or an l Waste Gas Canister in house oxygen source Save time and money gt ee nnn ome Refresh Canisters last twice as long capture gt Saves money in oxygen costs twice the amount of Isoflurane with less waste EE cid IGeRNCHCee and increased safety With a decrease in canister changeovers there is potential for cost savings of tank changes o IO up to 40 gt Proven reliability with thousands in use around the world gt Quiet operation at 49dB sound level KODEL lI E7 258 ReFresh Gas Canister case of 8 gt Easy portability with rollerbase design gt Maximum output flow rate of up to 8LPM and fixed pressure of 20psi F AIR Canister gt Weight is manageable at 54 Ibs A sensible answer to anesthesia gas problems in gt Able to supply oxygen to multiple systems simultaneously the operating room the F AIR anesthesia gas filter gt Well suited for use in barrier facilities i was specifically designed to remove waste MODEL DESCRIPTION anesthesia gases from the operating room EZ R20C Oxygen Concentrator environment Economical to use with an average useful life of 12 to 15 hours F AIR is easily adaptable to anesthesia machines F AIR can remove no less than 50 grams of pure halogenated anesthetic gases and can then be conveniently discarded MODEL DESCRIPTION F AIR F Air Canister F AIR CS F Air Canister case of 8 F AIR KIT F Air Kit Includes holder scavenger tube and one canister Coaxial Bre
203. tant temperature A unique chemical solution contained within a durable pouch is in solid form at room temperature When heated the solution becomes fluid and the pad is ready to use When an animal or container is placed in contact with an activated pad heat is transferred and the solution slowly undergoes a phase change During this change over 30 calories are available per gram of solution and the temperature remains constant The pad remains isothermal until all of the liquid phase has solidified Experimental studies have shown that the pad temperature of 39 C is ideal for maintaining animal or cultures at 37 C If desired one or more pads may be placed within a foam box to create a bench top or portable incubator Laboratory Evaluation Rectal temperatures of two rats during six hour experiment Animal weights 350g room temperature 24 5 C Animal on Deltaphase Isothermal Pad maintained near normal temperature for more than three hours a gt Warming Pads The Deltaphase Isothermal Pad has been evaluated by researchers at a major medical center Anesthetized rats pentobarbital 45mg kg were placed on either an operating table or a Deltaphase Pad and rectal temperature was monitored for six hours The temperature of the rats on the conventional table fell rapidly and stabilized only near 30 C when pronounced shivering began The rats on Deltaphase Isothermal Pad maintained body temperature near a
204. tching power supplies which are smaller and lighter than the older BFS supplies Supplies are overrated 100 to ensure cool operation and continuous service safety features include over temperature alarm with power shut down in event of inadequate flow of cooling water or overuse of the thaw feature gt Frozen tissue sections from most microtomes gt Fast freezing preserves cell detail gt Freeze to temperatures as low as 40 C gt Temperature adjustable for optimum cutting gt Quick thaw for easy cleanup gt No CO needed minimal cost to run Innovative New Stage Design An etched grid on top plate promotes better adhesion of frozen sample Thinner stage design reduces need for a knife raising block Waterways inside stage are redesigned to create a single passage to improve heat transfer and reduce potential for blockage Single large peltier module results in uniform temperature across the entire surface of stage Redesigned mounting hardware facilitates the direct attachment of blocks or posts to underside of stage and a new adapter plate system allows mounting on a variety of different microtomes Safety Features gt Controller incorporates fan assisted internal cooling to maintain low internal component temperatures gt Continuous display of both set and run temperatures gt Simple digital temperature control set up gt Auxiliary switched AC output for accessories gt P D microprocessor based temperature cont
205. teel will not rust crack or bend Research rats are housed in either metal wire bottom cages or plastic solid bottom cages called shoeboxes Wire bottom cages are the preferred industry cage due to cleanliness and low labor maintenance However rats housed in these cages may develop lesions on their feet from constantly being on wire mesh Shoebox cages use bedding which addresses animal welfare concerns but also carry increased operational costs to maintain acceptable sanitary conditions research facilities using these cages must replace the bedding frequently Designed by a researcher who is genuinely concerned with the welfare of rats and is aware of the concerns of researchers gt Increases floor space per cage gt Stainless steel is easily cleaned and durable gt No replacement or disposal issues gt Less expensive over time than disposable and plastic devices gt Allows nursing mother rats a place of refuge from pups gt Seems to have a calming effect on rats gt Easy to install and remove gt New hinged floor design allows researcher to access rat if beneath it MODEL DESCRIPTION Rat Loft 4 x 6 Hinged perforated deck Rodent Work Stand Rodent Work Stand is designed to support rats mice and similar small rodents in a stable and comfortable position for the technician during endotracheal intubation and intratracheal dose instillation and other similar procedures 12 wide x 14 deep x 5 375 high when f
206. temperature can be selected independently in increments of 0 1 C making this MyBlock the eal choice for the most temperature sensitive applications including immunoassays LAMP assays enzyme reactions and other temperature hyper sensitive procedures gt Heated lid prevents evaporation and condensation gt Compact fits in the palm of user s hand gt Independant temperature control of lid and block gt Exchangeable blocks for 0 2 to 0 5ml tubes gt Room temperature to 37 C in just 2 minutes Specifications Temperature range Ambient 5 to 100 C Temperature accuracy 0 3 C Temperature increments 0 1 C Temperature uniformity 0 2 C Dimensions 4 x 6 x 4 5 10 5cm x 15cm x 11 5cm MODEL DESCRIPTION BSH200 HL MyBlock HL Mini Dry Bath with Heated Lid Additional Blocks BSH100 02 Block 40 x 0 2ml tubes or 5 PCR strips of 8 tubes each BSH100 05 Block 24 x 0 5ml centrifuge tubes Visit us online at www braintreesci com 51 7231BRASCI_NOPRICE 12 13 12 11 40 AM Page 52 Lab Equipment 271 ENDURO Semi Dry Blotter The ENDURO Semi Dry Blotter provides great flexibility in a lab since it can be used for all types of blotting Western Southern and Northern Blotting with the ENDURO Semi Dry Blotter typically can be done in 15 to 30 minutes making it fast and easy Set up procedures are easy and economical with little buffer needed Screw down lid adjusts to varying gel
207. tereotaxic Cunningham Mouse and Neonatal Rat Adaptor The original Cunningham Mouse and Neonatal Rat Adaptor fits Stoelting Lab standard and most other brands of stereotaxics It employs light tapered Delrin ear bars to facilitate surgery on mice and rat pups The Cunningham Mouse and Neonatal Rat Adaptor features an increased overall length to accommodate larger animals and new specialized jaw holder cuffs providing an alternative non invasive means of securing the animal s head in the stereotaxic stage Fully compatible with masks for gas anesthesia MODEL DESCRIPTION 51625 Neonatal Rat Adaptor Digital Lab Standard Stereotaxic Instrument Digital Lab Standard features a sealed electronic sensor highly immune to interference and environmental conditions Movements are monitored by a large easy to read LED display module and are accurate to 10uL A zeroing function allows the user to target specific coordinates in the brain for injection implantation etc Calculation of distance measurements via the vernier scales is thus no longer necessary saving the user valuable time and improving accuracy MODEL DESCRIPTION 51900 Digital Lab Standard 18 Ear Bars 51950 Digital Lab Standard 45 Ear Bars 51903 Dual Digital 18 Ear Bars 51953 Dual Digital 45 Ear Bars Digital Just For Mice Stereotaxic Instrument Two stereotaxic instruments in one Stoelting Just For Mice Ster
208. the breathing hole at the small end Roll and squeeze the large end closed They may be used repeatedly for injections and simply discarded when soiled For decapitation hold at the rear and insert the small end into the decapitator MODEL DESCRIPTION MDC 200 For Mice 200 Decapicones 2 dispensers contain 100 cones each For Rats 200 Decapicones 4 dispensers contain 50 cones each For Large Rats 500 8009 120 Decapicones 4 dispensers contain 30 cones each MDC 200 DC 200 DCL 120 Rotating Tail Injector Reduce time and increase productivity on mice tail injections and tattooing The only mouse restrainer in which the tail can be rotated This feature provides for easy access to either vein in the tail for an i v injection Animal chamber accommodates mice weighing up to 45g RTI is ideal to adequately restrain an g unanesthetized animal while having the tail vein straight in line with user s eyes for a successful injection A pattern of airholes provide ventilation as well as a toe hold for the mice The unit sits comfortably on a bench top or in a laminar flow hood and it can be U V sterilized for use with immunocompromised mice The raised table top lets user rest their hands to administer the injection MODEL DESCRIPTION RTI Rotating Tail Injector for mice up to 45g RTI I Standard Replacement Tube Restrainers Howard Flip Restrainer i The Howard Flip lsa x Restrainer
209. the laboratory mouse at four different magnifications Includes 344 full color microphotographs and 15 full color diagrams Clear diagrams show the relative positions of organs and up to date information about the histology and microanatomy of the mouse Content is easily accessible via the menu and a search engine Systems covered Integumentary system hematopoietic and lymphopoietic systems heart gastrointestinal respiratory urinary male female reproductive systems endocrine organs nervous system and sense organs MODEL DESCRIPTION CD MHST Atlas of Laboratory Mouse Histology Hizb o es i ep Rat Models KOKEN RAT Experiment techniques training model When various experimental procedures are conducted using laboratory animals it is important to restrain the animal properly and to develop techniques that will meet the necessary experimental objectives The beginner can learn the techniques of proper holding peroral feeding tail vein injection and blood collection and endotracheal intubations Characteristics gt Pharynx larynx trachea stomach and tail vein are anatomically correct and replicated inside the model of the rat gt To achieve a texture similar to that of a live rat original silicone and soft vinyl chloride are used gt When placed in position the posture is the same as that of a live rat gt Dosage in the stomach can be confirmed because part of the abdomen is transparent
210. to object from Omm Accuracy Outside of the 25 40 C Range 1 1 C Minimum Measurement Size 3mm Other Emissivity fixed undisclosed value MODEL DESCRIPTION IR B153 Infrared Thermometer Infrared Thermometer Pocket Infrared Thermometer The absolute best value in palm sized IR thermometers Professional 6 1 optics give a 1 measurement spot at a 6 distance Many pocket units offer only 1 1 which means the user has to be nearly touching the surface for an accurate reading Fits comfortably in palm with trigger button on side Simple mode button steps through Max Min C F and adjustable emissivity Includes gt Infrared thermometer gt Neck lanyard gt 2 CR2032 batteries pre installed gt User manual with certificate of conformance Specifications Range 67 to 482 F 55 to 250 C Accuracy 3 6 F 42 C 2 of reading or whichever is greater Resolution 0 1 F or C to 199 9 1 above Units Switchable F to C Response 1 second Distance target 6 1 1 target diameter at 6 distance Emissivity Default 0 95 adjustable 0 05 to 1 in 0 01 increments Environmental range 32 to 122 F 0 to 50 C Battery 2x CR2032 included 40 hours Wavelength 5 14um Dimensions 0 9 x 2 x 4 22 5mm x 50mm x 103mm gt Weight 2 3 oz 65g including battery MODEL DESCRIPTION IR TW2 Pocket Infrared Thermometer 27 Close Focus Infrared Thermometer gt 0 7 18mm measurement distance
211. to place gt Allows for easy flip up of optics gt Allows for secure adjustments of your settings gt Provides stable alignment of optics Choosing the right loupe follow these two steps for a perfect match Step 1 Choose magnification Start with the lowest power you need Most professionals begin using loupes with a magnification power of 2 5X Remember as the magnification increases the field of view focal range and light transmission decreases Step 2 Choose working distance All loupes are pre set to focus at a certain distance and objects will remain in focus within a range of several inches Loupes are available in 4 working distances Short 10 13 regular 12 16 long 14 18 and extra long 16 20 The 250 Series 2 5x is the ideal general purpose optic The 250 series optic will provide a magnified view of approximately 2 5 times the object size Most first time loupe users choose this magnification The 300 Series 3x is an ideal optic for those who have worked with a 2 0X Magnification power optic and want an increase in power The 300 series optic provides a view of the entire area of focus and has an excellent depth of focus The 350 Series 3 5x is the highest magnification optic available in a compound lens design The 350 series optic is an excellent choice for dentists and surgeons requiring high magnification in a lightweight loupe Kit contains head strap screwdriver storage case cleaning cloth sol
212. ton Ergonomically positioned tip ejector reduces fatigue during prolonged use Discovery pipettes have a universal shaft that accepts most pipette tips Tip ejector is adjustable to accommodate various styles of tips and removable for pipetting into narrow tubes Made from stainless steel it will not rust corrode or break Discovery pipettes are fully autoclavable MODEL DESCRIPTION P3940 2 Labpette Discovery Pipette 0 1 2uL P3940 10 Labpette Discovery Pipette 0 5 10uL P3940 20 Labpette Discovery Pipette 2 20uL P3940 100 Labpette Discovery Pipette 10 100uL P3940 200 Labpette Discovery Pipette 20 200uL P3940 1000 Labpette Discovery Pipette 100 1000uL P3940 5000 Labpette Discovery Pipette 1000 5000uL P3940 10000 Labpette Discovery Pipette 1000 10000uUL P4508 10 Labpette Discovery Eight Channel Pipette 1 10uL P4508 50 Labpette Discovery Eight Channel Pipette 5 50uL P4508 200 Labpette Discovery Eight Channel Pipette 20 200uL P4508 300 Labpette Discovery Eight Channel Pipette 50 300uL P4512 10 Labpette Discovery Twelve Channel Pipette 1 10uL P4512 50 Labpette Discovery Twelve Channel Pipette 5 50uL P4512 200 Labpette Discovery Twelve Channel Pipette 20 200uL P4512 300 Labpette Discovery Twelve Channel Pipette 50 300uL P3940 4P Labpette Discovery 4 Pack Plus Includes 4 Discovery Pipettes P3940 10 20 200 1000 One Carousel Stand and 3 Racks of BioFree Tips Labnet BioFree Pipette Tip
213. trainers in small medium and large Each unit A SE TA has an open slot on the bottom for F PO a intra peritoneal injections a hole on ey P A the top for the neck and a slotted tail 5 piece for intravenous injections L Front slots provide ample ventilation S MODEL DESCRIPTION FB S SmallMouse Restrainer for mice 15 to 30g 1 5 D x 4 3 81cm D x 10 16cm FB M Medium Rat Restrainer for rats 30 to 1259 2 D x 5 5 08cm D x 12 70cm Medium Large Rat Restrainer for rats 125 to 250g 2 5 D x 6 6 35cm D x 15 24cm FB L Large Rat Restrainer for rats 250 to 500g 3 375 D x 8 5 8 57cm D x 21 59cm FB M L IN ar 7231BRASCI_NOPRICE 12 13 12 11 35 AM Page 17 Restrainers Mouse Tail Illuminator The mouse tail illuminator efficiently illuminates and warms a mouse tail for easy injection or bleeding Each unit comes with a restraining tube and illumination source Additional tubes are available gt Restraining tube slides off base for easy cleaning gt Illuminated slot for easy tail vein injection etc gt Sliding doors keep mouse gently restrained DESCRIPTION MTI Mouse Tail Illuminator MTI 1 Standard Replacement Tube MTI 2 Smaller Tube 1 125 MTI 3 Rotating Tube illuminated Rodent Tail Vein Unit Offers an illuminated rodent tail vein unit featuring brite light illumination system with rechargeable batteries and recharger unit gt Clear plastic tail i
214. treesci com 1 7231BRASCI_NOPRICE 12 13 12 11 32 AM Page 2 Tubin RenaSil Silicone Rubber Tubing Renasil is a Platinum cured silicone tubing that is inert and contains no harmful leachable plasticizers It is essentially non reactive The tubing will maintain its flexibility through a temperature range of 100 F to 500 F storage temperature and humidity have virtually no effect on silicone tubing therefore shelf life is unusually long This tubing may be autoclaved and re sterilized without altering physical characteristics RenaSil meets the standards of the US Pharmacopoeia Class IV and CRF 21 Part 177 2600 for food additives All sizes are packaged clean without talc and sealed in polyethylene bags Supplied non sterile MODEL DIMENSIONS SILO25 0 025 OD x 0 012 ID 0 64 OD x 0 30 ID mm SILO37 0 037 OD x 0 025 ID 0 94 OD x 0 64 ID mm SILO47 0 047 OD x 0 025 ID 1 19 OD x 0 64 ID mm SILO65 0 065 OD x 0 030 ID 1 65 OD x 0 76 ID mm SILO80 0 080 OD x 0 040 ID 2 03 OD x 1 02 ID mm Polyethylene Tubing Polyethylene is a relatively rigid polymer suitable for short term catheterizations and for ex vivo applications Polyethylene sleeves can be Slipped over less rigid catheter materials Micro Renathane Renasil at suture points to protect the latter from inadvertent constriction Supplied non sterile Minimum order 36 feet MODEL DIMENSIONS PE10 0 024 OD x 0 011 ID 0 60
215. ts neurology physiology The Laboratory Rat toxic tests pharmacological effectiveness tests etc Anatomy is one of the important basic sciences and although much progress has been recently made in the field of human imaging diagnosis information on sectional By Patrick Sharp and Marie LaRegina Washington University School of Medicine St Louis Missouri anatomy of experimental animals is lacking at present The Laboratory Hamster and Gerbil gt Specimens were not fixed but kept in a frozen state so that photographic By Karl Field Hoffman LaRoche Inc Nutley New Jersey information close to the living state could be obtained Amber Sibold Sandoz Pharmaceuticals Inc East Hanover New Jersey gt All photographs are in color for detailed observation i i gt Each atlas has numerous color pages 2 pages of black and white The Laboratory Guinea Pig macro anatomical photographs are provided By Lizabeth Terril Robb VPR LAP Purdue University West Lafayette Indiana gt All pages consist of photographs making detail more comprehensive and Donna Clemons Corning Hazelton Madison Wisconsin three dimensional than the usual pictorial atlas MODEL TITLE gt The anatomical terms used are in Japanese and English LABMOU The Laboratory Mouse MODEL TITLE LABRAT The Laboratory Rat SECT MOU A Color Atlas of Sectional Anatomy of the Mouse LABHAM The Laboratory Hamster and Gerbil SECT RAT A Color Atlas of Sectional Anatomy of the Rat LABGP The Laboratory Guinea
216. turer generally chooses plasticizers stabilizers antioxidants colorants etc which are acceptable for food use Micro Renathane does not contain any plasticizers Medical Uses of Polyurethane Polyurethane based polymers were introduced into the United States from Germany Early biomedical applications of polyurethanes were described by Boretos and Pierce They reported excellent vascular acceptability in experimental heart assist pump chambers and arterial cannulae In subsequent work Boretos reported the absence of acute toxicity for segmented polyurethanes He also reported that polyurethane rings did Tubin not deteriorate or cause tissue reaction after implantation for 18 months Lyman and coworkers have also investigated polyurethanes for the fabrication of heart assist devices Artificial heart devices were constructed of this material and implanted in calves Other uses of polyurethanes as biomaterials have been described by Bruck Polyurethane based polymers are currently commercially employed in hollow fiber kidneys vascular catheters and intra aortic balloons Due to the slightly higher cost of polyurethanes they have only been used where exceptional biologic and blood compatibility is required Micro Renathane is sold only for experimental use in laboratory animals A brief report with references is included with each shipment of Micro Renathane We will be pleased to send a copy upon request Same price as 1989
217. uard Protection for Irradiated Animals Because Rad Disk and Rad Disk Mini are made entirely of polycarbonate plastic it is autoclavable The two cage sizes are designed to fit into radiation chambers 5 high and 9 diameter and larger Used as instructed Rad Disk and Rad Disk Mini prevent contamination of mice before during and after irradiation They are also a versatile carrier to protect rodents while transporting them in and out of facilities Cage Divider System Rad Disk and Rad Disk Mini include a polycarbonate removable divider system which divides cages into four to eight compartments for irradiation Used without dividers mice can also free range which allows greater uniformity of dose delivery during irradiation Imbedded Jump Guard Rad Disk and Rad Disk Mini include a polycarbonate piehole cutout cover that can be easily rotated over each divided chamber to insert rodents and prevent escape or jump to adjacent chambers Protection from Contamination Rad Disk and Rad Disk Mini are autoclavable with lid in place Within a changing hood animals are transferred from their housing into sterile protective environment of Rad Disk and Rad Disk Mini using standard microisolation techniques Lid contains a 3 ply filter which can be used up to 6 months or 12 autoclave cycles Lid has aligned air holes through which potential airborne contaminants are trapped on exterior of filter After transferring animals into
218. uge 6C to fit on even the most crowded bench Its rugged construction will provide years of trouble free operation Centrifuge can be operated on bench or in a cold room MODEL DESCRIPTION C0060 Spectrafuge 60 Clinical Laboratory Centrifuge with 6 x 10 15ml rotor CO0200 17A Combination Adapter Set for 5ml and 7ml tubes pack of 6 Centrifuges 27 Prism Mini gt New rotor designs for increased sample capacity gt Self opening lid enables single handed operation gt Quick release rotor hub allows for easy rotor exchange gt Built in braking system for rapid sample processing Reliable and easy to use the Prism Mini is compact and economical allowing each workstation to be equipped with a personal centrifuge Ideal for quick spins it can be used for a wide range of molecular biology separations It s extremely compact with an exceptionally small footprint Includes two quick release interchangeable rotors which spin up to 6000 RPM s The electronic brake and self opening lid allow for quick deceleration to reduce handling time A maintenance free drive system and unique design allow for quiet operation and excellent air flow to protect temperature sensitive samples Cold room compatible Self opening lid Engineered with the lab technician in mind transparent blue lid allows for a clear view of samples in the rotor Start and stop of centrifuge can either be controlled by on off switch or by activating self o
219. ution magnification loupe and frame oO WORKING FIELD OF MODEL MAGNIFICATION DISTANCE VIEW COLOR LP 5000 2 0X 10 13 S 3 5 S Red LP 5001 2 0X 12 16 R 3 8 R Red LP 5002 2 0X 14 18 L 4 3 L Red LP 5003 2 0X 16 20 XL 4 6 XL Red LP 5011 2 0X 10 13 S 3 9 S Black LP 5012 2 0X 12 16 R 3 8 R Black LP 5013 2 5X 14 18 L 4 3 L Black LP 5014 2 5X 16 20 XL 4 6 XL Black LP 5004 3x 10 13 S 2 8 S Red LP 5005 3x 13 16 R 2 5 R Red LP 5006 3x 16 21 L 3 5 L Red LP 5007 3x 18 22 XL 4 XL Red LP 5015 3x 10 13 S 2 8 S Black LP 5016 3x 13 16 R 2 5 R Black LP 5017 3x 16 21 L 3 5 L Black LP 5018 3x 18 22 XL 4 XL Black For 3 5x visit braintreesci com IN ar 7231BRASCI_NOPRICE 12 13 12 11 42 AM Page 69 a Microscopes and Loupes Stereo Zoom Microscope System ZoomMaster is equipped with focusing eyepiece tubes and an adjustable inter pupillary distance of between 50mm and 75mm Rotatable through We x 360 body has a 74mm diameter compatible with major OEM configurations 10x focusing eyepieces with eyecups are supplied as standard providing a 10x to 40x magnification and a long working distance Zoom Master 65 EYEPIECES EYEPIECE EYEPIECE EYEPIECE AUXILIARY WORKING 10x 15x 20x 25X LENS DISTANCE MAGNIFICATION RANGE 0 5x 189mm 3 5x 22 5X 5 3X 33 8X 7X 45x 8 8x 56 3x non
220. w profile design gt Color coded sealed keypad gt Low cost and simple to use gt External calibration gt Battery power 6 x AA Batteries gt Auto sleep power down function to save battery life gt AC Adapter MODEL CAPACITY PLATFORM SIZE READABILITY CQT 202 200g 47 120mm dia 0 01g CQT 251 250g 4 7 120mm dia 0 1g CQT 601 600g 4 7 120mm dia 0 1g CQT 1501 15009 4 7 120mm dia 0 1g CQT 2601 26009 5 7 145mm dia 0 1g CQT 2000 2000g 5 7 O 145mm dia 1g CQT 5000 5000g 5 7 0 145mm dia 1g Dune Compact Balances gt 3 weighing units g Ib oz gt Full range tare gt Zero Tracking gt Large easy to read LCD display gt Overload protection gt Color coded sealed keypad gt Lightweight and portable gt Simple user friendly operation gt Precision load cell technology gt Splashproof to protect from accidental spills gt External calibration gt Battery power 6 AA batteries gt Low battery indication gt Auto sleep power down function to save battery life gt AC Adapter SPECIFICATION DCT 201 DCT 2000 DCT 5000 Capacity 200g 2000g 5000g Readability 0 19 1g 2g Pan Size 5 7 xX 5 7 5T X5 5T XBT 56 BRAINTREE SCIENTIFIC 781 348 0768 Specimen Box with cover ae specimen box holds rodents for ag weighing purposes Specifications Dimensions 4 H x 9 W Weight 157g MODEL DESCRIPTION SB 8053 Specimen Box with cover M Prove Pre
221. way to generate reliable data For use A with ALZET pumps for targeted delivery to the central nervous system gt Infusion into cerebral ventricles exposes a wide variety of brain regions to infusate via cerebrospinal fluid which bathes brain gt Direct microperfusion of discrete brain structures results in localized distribution of infusate in target tissue Includes materials for 10 brain infusions 10 brain infusion cannulae 10 vinyl catheter tubes 40 depth adjustment spacers and instruction sheet MODEL DESCRIPTION BIFKIT1 28g 3 5mm L BIFKIT2 28g 3 mm L low profile wide pedestal BIF KITS 30g 1 3 mm L low profile wide pedestal W Intravenous Osmotic Pump Catheter cn ia tS 1 pt Eiri ara da FFEN y oe rit ied nite G aI aa J ALAT A i ni p ve aeia lia M i Wat irr i We 4 ita Sate Teed Braintree Scientific s Micro Renathane based catheter for the continuous intravenous via the jugular vein administration of drug solutions delivered with the ALZET Osmotic Pump Catheter can be modified for infusion via other blood vessels please inquire Supplied non sterile MODEL DESCRIPTION R JVC AP Rat Intravenous Osmotic Pump Catheter M JVC AP Mouse Intravenous Osmotic Pump Catheter Visit us online at www braintreesci com 61 7231BRASCI_NOPRICE 12 13 12 11 41 AM Page 62 Peristatic Pumps BS 900 Programmable Peristatic Pump Have a need to accurately fill multiple bottl
222. ways clean gt Delivery tube within chamber fills chamber from bottom decrease induction time more humane gt Clear acrylic top easy to see animals in chamber gt Solid sides prevents viewing of animals during the process gt Includes see thru acrylic lid with door and quick connect with valve 7 tubing 50 disposable insert bags acs MODEL DESCRIPTION COIC C02 Chamber COBL Disposable Liner Bags 50 bags pk ppeshiesia WorkStation Compact 9 W x 9 D x 15 H convenient system for use on animals under 7 kg 15 Ib In clinical trials the AWS is being used for long term anesthetic procedures on 150 400gm rodents AWS has been shown to be effective with induction stabilization and maintenance of patients for neurophysiological testing using inhalant anesthetics for daily 8 to 12 hour procedures Using the AWS rats under isoflurane anesthesia have been subject to extended aero recordings of cortical responses Throughout these procedures AWS has been shown to facilitate administration of anesthetics holding the subject in a very smooth controllable anesthetic plane as well as providing precise respiratory control Hallowell EMC Anesthesia Workstation is easy to use as both a basic respirator irrespective of anesthetic regime and delivery source for inhalant anesthetics It incorporates a time cycled volume ventilator with an adjustable pressure safety limit The only additional component nece
223. with Velcro fasteners providing adjustable and secure fit for individual animals Neck openings are bound with cotton jersey for comfort and light padding MODEL DESCRIPTION EC M1 Elizabethan Collar for Mice 2 75 EC R1 Elizabethan Collar for Rats up to 450g 4 625 EC R2 Elizabethan Collar for Rats 450g 5 125 Swivel Rodent swivels are made from durable plastic and are fitted with a 20g or 22g needle Designed for long life and repeated usage Sterile packaged MODEL DESCRIPTION RS 20G Gas Sterilized 20g RS 22G Gas Sterilized 22g Swivel Mount Rodent swivel mount secures to the outside of the cage Comprised of a retainer made of durable plastic with a stainless steel clip MODEL DESCRIPTION RSM Rodent Swivel Mount D Tethers Constructed from lightweight stainless steel spring coil rodent tethers come complete with a crimped end for direct attachment to the rodent swivel removing the need for potentially troublesome connection hardware Jacket anchors comes ready sewn with silver woven fabric for added comfort and resistance to opportunistic infection Rodent tethers are designed to protect the exteriorized catheter and can be used with rodent jackets MODEL DESCRIPTION RT 12 Tether 12 sewn RT 18 Tether 18 sewn YEARS 1980 2012 AZ Braintree Scientific IN ar 7231BRASCI_NOPRICE 12 13 12 11 41 AM Page 61 AutoMate In Vivo Manual Gravity Perfusion System Take the guesswork out of
224. x 0 28mm PE20 0 043 OD x 0 015 ID 1 09 x 0 38mm PESO 0 038 OD x 0 023 ID 0 965 x 0 58mm PE60 0 048 OD x 0 030 ID 1 22 x 0 76mm PE100 0 060 OD x 0 034 ID 1 52 x 0 86mm PTFE Heat Shrink Tubing USP Class VI Approved Medical grade polyetrafluoroethylene tubing has high tensile strength and preserves high fidelity pressure waveforms with very small internal diameter tubing PTFE heat shrink tubing can be shrink fitted to make secure connections with other devices 2 1 heat shrink ratio Supplied non sterile MODEL EXP ID REC ID REC WALL TOL PTFE 015 0 034 ID 0 86mm 0 015 ID 0 38mm 0 006 0002 PTFE 018 0 038 ID 0 97mm 0 018 ID 0 46mm 0 009 0 002 PTFE 032 0 055 ID 1 4mm 0 032 ID 0 81mm 0 012 0 003 PTFE 039 0 060 ID 1 5mm 0 039 ID 0 99mm 0 012 0 003 2012 Zeus Industrial Products All rights reserved 2 BRAINTREE SCIENTIFIC 781 348 0768 PTFE Sub Lite Wall Tubing A major breakthrough in micro miniature tubing USP Class VI Approved Medical grade polyetrafluoroethylene tubing has superior lubricity and slides easily into tiny convoluted passages No residue build up inside tubing non toxic non contaminating and easily sterilized excluding Gamma Compatible with tissues and fluids yet withstands moisture it is chemically inert and stable Continuous service temperature up to 500 F Supplied non sterile MODEL OD ID WALL SUBL 060 0 006 x 0 002 0
225. y Blue Wax is specially formulated to provide the proper consistency to allow pins to stick firmly and be easily removed MODEL DESCRIPTION QTY PK TPD L Large Tissue Processing Disc 4 dia 0 25 thick 10 TPD M Medium Tissue Processing Disc 2 75 dia 0 25 thick 10 TPD S Small Tissue Processing Disc 2 dia 0 25 thick 10 TPIN Ball Head Tissue Pins S S 1 5 long 6 2 eee eae 50 27 Blue Wax Dissection Tray Add a dissection tray with a wax base pinning surface for detailed dissections Specially formulated to provide proper consistency to allow pins to stick firmly and be easily removed Dissection tray uses a completely environmentally safe wax product instead of black wax like product used in most other dissection trays MSDS sheet for this product lists no toxic chemicals and no fire health or reactivity hazards with this product Blue Wax can be heated to renew surface and dissection tray can be reused several times MODEL DESCRIPTION DIW1 Dissection Tray 9 5 x 7 x 1 DTW5 Dissection Tray five trays per pack Visit us online at www braintreesci com 35 7231BRASCI_NOPRICE 12 13 12 11 38 AM Page 36 CIN SU PCR Plates Tubes and Seals 96 Well PCR Plates Low Profile Skirted Semi Skirted Raised Deck gt Designed to reduce dead space and prevent g ae A condensation on side wall gt Semi skirted plate designed specifically
226. zes Temperature shaking speed and run time are displayed on large LED control panel located on front of unit Integral microprocessor includes a constant monitoring system that verifies and maintains accuracy through duration of program Sophisticated over temperature and over speed controls ensure long life safety and sample integrity Applications Bacterial suspensions staining destaining tissue cell culture gel washing solubility studies general mixing diagnostics general incubation Technical Data Temperature range Ambient 5 to 60 C Increments of 0 1 C Temperature uniformity 0 25 Temperature accuracy 0 1 Shaking speed range 30 to 300 rpm Increments of 1 rom Shaking orbit 19mm 3 4 Platform dimensions 9 5 x 11 5 23 5cm x 29 2cm Exterior dimensions 11 x 15 7 x 10 5 lid open height 25 28cm x 40cm x 27cm lid open height 63cm MODEL DESCRIPTION H1000 M Incu Shaker Mini Shaking Incubator H1000 MR Magic Clamp universal platform for flasks and tube racks clamps sold separately H1000 MR 500 Clamp for Magic Clamp platform 500ml max 5 H1000 MR 250 Clamp for Magic Clamp platform 250ml max 8 H1000 MR 125 Clamp for Magic Clamp platform 125ml max 12 H1000 MR 50 Clamp for Magic Clamp platform 50ml H1000 MR 1550 Tube rack for Magic Clamp platform 12x50 and 21x15ml conical tubes max 1 H1000 P 500 Dedicated platform with 5 x 500ml Erlenmeyer flask damps attached H1000 P 2

Download Pdf Manuals

image

Related Search

Related Contents

Benutzerhandbuch - SENA Bluetooth Headset    NINE CHOICE SERIAL REACTION TIME TASK  Manhattan 308908  Trevi CMP 542 USB  La communication non violente : mode d`emploi La bienveillance  MANUALE UTENTE KD300.indd  Répartition des groupes & début de l`attribution  Curriculum Vitae Raúl Mújica Garc´ıa  

Copyright © All rights reserved.
Failed to retrieve file