Home

Manual SOPHIA Bathroom Heater 15,12,11

image

Contents

1. buttons IMPORTANT BACKGROUND Temperature has to be lower or equal to the Comfort Temperature and the priority is assigned to the Comfort Temperature For this reason Night Temperature can only be set in the range 7 C Comfort Temperature whereas the Comfort Temperature can be set within the whole range 7 32 C and in case of a value lower than the Night Temperature the system will automatically re set the new Night Temperature at the same value as Comfort Temperature OPERATING MODES Press the Prog button to shuffle between the different operating modes An icon on the display indicates the current operating mode please see the charts below and on page 5 gr F T 4 r a ho vad d a bod boi e hd PTa te PTa r kga i iji I i Ime OPERATING MODES CHART DIAL DIAGRAM DESCRIPTION Daily and weekly programming for the two temperature levels Comfort and Night All Pilot wire commands are disabled Pilot wire programmer mode All settings temperatures depend on the Pilot wire programmer All Pilot wire commands are enabled The comfort temperature corresponds to the temperature set by the user Regulation to the high range temperatures All Pilot wire commands are disabled Night temperature reduction mode to maintain a comfortable temperature with mini mum energy consumption Regulation to the low range Temperatures All Pilot wire commands are disabled Frost protection minimal temper
2. to If the cable or any other electrical part fails or becomes damaged repair or replacement must be carried out by an electrician approved by the manufacturer or by a suitably qualified experienced electrician familiar with such products who has the necessary instructions This product must not be positioned below an electrical socket and all applicable regulations relating to the installation of electrical appliances in bathrooms splash areas must be fully adhered to See page 4 for further information and guidance WARNING to avoid the risk of injury to children this appliance should be installed so that the lowest heated rail is at least 600mm above the floor During normal operation it is normal for the bottom pipe and the top one not to heat up This is to facilitate the flow and expansion of the thermodynamic fluid Do not use this appliance near sources of gas explosives or flammable liquids NEVER connect the BLACK PILOT WIRE to an EARTH LIVE or NEUTRAL connection The black pilot wire is a signal wire It is only to be used for connection to an external Hard wired Pilot wire Programmer Connection of the PILOT WIRE to any LIVE LINE NEUTRAL or EARTH connection will destroy the thermostat If the black pilot wire is not to be connected to an external pilot wire programmer it must be insulated isolated to ensure this does not occur 3 BATHROOM INSTALLATION GUIDELINES This electric heater complies wit
3. INSTALLATION GUIDE AND USER MANUAL The SOPHIA Towel Rail Bathroom Heater With integral Seven Day LCD Programmer Please ensure that these instructions and guidelines are fully understood and adhered to when installing and using this appliance TABLE OF CONTENTS Integral Seven Day LCD Intelligent Programmer Palen Onin LCD Display with blue back light Minus control Programming On Off Receiver Manual switch IMPORTANT GENERAL GUIDELINES Installation and all maintenance must be carried out by a qualified person This appliance must not be used operated by people including children whose sensory physical or mental capabilities prevents them from doing so safely Take special care when children are around and ensure that they do not tamper with the appliance The manufacturer cannot be held responsible for any fault damage or personal injury caused in the event of these instructions not being fully adhered to or where non original materials or accessories have been used Such non observance would also invalidate the warranty This heater is filled with a special Thermodynamic Fluid Any repair involving opening the access to this fluid must be carried out by an electrician approved by the manufacturer The manufacturer must be contacted in the unlikely event of any leakage of this fluid Please note that all regulations for the disposal of heating fluid and electrical appliances must be fully adhered
4. In this zone a minimum rating of IP44 is required If the fitting is 240v a 30ma residual current device RCD must also be used to protect the circuit in this zone Zone 2 is an area stretching 0 6m outside the perimeter of the bath and to a height of 2 25 from the floor In this zone IP rating of at least IP44 is required In addition it is good practice to consider the area around a wash basin within a 60cm radius of any tap to be considered as zone 2 Zone 3 This Zone Has Now been Withdrawn From the 17th Edition of the regulations In addition to the above if there is a likelihood of water jets being used for cleaning purpose in zones 1 and2a fitting rated a minimum IP65 must be used IP Explanation and Ratings EN 60529 outlines an international classification system for the sealing effectiveness of enclosures of electrical equipment against the intrusion into the equipment of foreign bodies i e tools dust fingers and moisture This classification system utilizes the letters IP Ingress Protection followed by two or three digits A third digit is sometimes used An x is used for one of the digits if there is only one class of protection i e IPX4 which addresses moisture resistance only WALL MOUNTING GUIDELINES A Front view showing positioning of wall mounting brackets two at the top one at the bottom the minimum mounting distance the highest part of the heater is to be fixed from the ceiling And if applicable the
5. at Intelligent Heating Solutions PLEASE ENSURE THAT YOU KEEP A RECORD OF THESE DETAILS Date of purchase hm ommmmmemmemmmmmmmmmmmmmmmmmmmmmmmmmmmmeere Date goods received _______ Model s purchased _____ SUPPLIER DETAILS Company Supplier name mime Telephone numbers _____ Email address mu gs dene ae leg dd Contact NaMe a ae dd dr ed de INSTALLER DETAILS Date of installation Company Trading name 2 Telephone numbers Email address oenn ae leg dd Contact name ___ _ LLL IntelliHcat Intelligent Heating Solutions INTELLI HEAT Ltd Company Registration Number 05950029 Unit 18 Napier Place Stephenson Way Thetford Norfolk IP24 3RL www intelligentheat co uk E tech intelligentheat co uk www intelligentheat co uk support Issue Reference MANUAL SOP 20 12 11
6. ature fixed at 7 degrees C to ensure protection against frost freezing damage The heater comes on automatically when the ambient temperature drops lower than 7 degrees C All Pilot wire commands are disabled This Mode can be used to heat a room quickly The heater will be set at the maximum temperature for two hours Stand by Heating element off All Pilot wire commands are disabled Heating Symbol g _ Set Temperature COO RN Aes ODG N Mode Icons 48 i og C x 201 lt 24h Time Symbol not used Infrared Receiver Comfort Mode Bar N Clock Weekly Program ee Key Lock Icon OPERATING MODES PROGRAMMING Comfort Mode The comfort temperature corresponds to the temperature desired by the user This operating mode is intended for the normal use of the appliance in order to heat the room Press the Prog button until comfort mode icon appears on the display fig 1 Page 7 e Modify the desired temperature if necessary using and buttons fig 2 Page 9 Night Mode In the night mode the temperature is usually lower than the set comfort temperature We recommend you use this mode during the night or when the room is empty for 2 hours or more in order to save energy Press the Prog button until night icon appears on the display fig 1 e Modify the desired temperature if necessary using and buttons fig 2 Anti frost Mode On the Anti frost mode the
7. ect the Black Wire to any terminal it must be properly insulated and isolated For the installation in a bathroom or a potential splash area RCD protection is essential and positioning and all electrical connections switching and installation must be compliant with all the regulations regarding installing electrical appliances in bathrooms see page 4 Only a qualified electrician should install this unit Power supply for single phase current 230V 50 Hz The connection must be made in compliance with the regulations in force before connecting the electric resistance to the line check the voltage and power values indicated on the data plate The electric supply circuit of the radiator must be protected by a 30 mA RCD protected circuit The opening distance between the contacts must be greater than 3mm Moreover the circuit must be easily accessible Power On Stand by mode Press ON OFF button fig 1 to turn the appliance ON or in Stand by mode When On the bottom area of the display shows the current time on the top the temperature setting is displayed COMFORT and BACKGROUND temperature setting Two different levels of temperature can be set COMFORT TEMPERATURE is the temperature setting for Chrono Pilot Wire or Fil Pilote and Comfort modes BACKGROUND TEMPERATURE is the temperature setting for the Night and Chrono mode In each mode the required temperature can be set by pressing the and
8. h the following directives 2006 95 CEE 89 336 CEE 2005 32 CEE and the norms EN 60335 2 43 2003 A1 2006 A2 2008 EN 60335 1 2002 A11 2004 A1 2004 Al2 2006 A2 2006 A13 2008 EN 62233 2008 OET M TONE ZONE int cy CL II 5 IP44 m zs i whGEMEWT a SG 2000 Ja ZONE ZONE ZONE pa f READY a T D a Z i fy gt sweet Fy 3 Fa 2 AGE AE T S nn SS pr mm for hr tr RN hi z za the perfect climate aA ii Bin me i i i p Er r soe rediua ft Technical Bathroom Information The following information is a guide to help you understand what electrical appliance can be placed where ina bathroom This is not an installation guide and reference should be made to the IEE Wiring Regulations 16th Edition or a qualified electrician Firstly it is important to understand the rating by which electrical appliances are classified IP rating stands for Ingress Protection and is always followed by two characters These two numbers refer to the level of protection and it is important that you choose fittings with the correct rating according to where they are to be sited within the bathroom The diagram above shows a bathroom split into three clear zones 1 2 and 3 Zone 0 is inside the bath or shower itself Any fitting used in this zone must be low voltage max 12v and be rated at least IP67 which is total immersion proof Zone is the area above the bath to a height of 2 25m from the floor
9. minimum distance the far sides of the heater is to be positioned from right angle walls B Side view showing the minimum distance the heater is to be fixed from the floor C View from the top showing rear distance from the wall PLEASE NOTE Rawlplugs and Screws for fixing the mounting brackets to the wall are not included due to the unknown construction of the wall that you intend to fix this heater to It is essential that this heater is mounted to the wall level and securely using the appropriate rawlplugs and screws A Minimum distance top of heater to B C be mounted from the ceiling 150 mm VALLLLLLLLLLLLLLLLLLLLLLLLLLLLL A SSN 1 277 SSS SS EE 10 min EO min Minimum distance sides of the heater to be Minimum distance heater to be positioned away from right angle walls 150 mm mounted from the floor 600 mm All dimensions in millimetres Drawings not to scale Product Specifications heights includes thermostat programmer Watts Height mm Width mm Depth mm Product Code Weight Kg 500 980 500 45 SOP 500 leo 750 1430 500 45 SOP 750 22 5 ELECTRICAL CONNECTION OPERATING MODES This heater is Double Insulated therefore it must not be connected to Earth and the cable does not contain an Earth wire Green Yellow The cable for this heater has the following cables Grey or Blue Neutral Brown Live Black Pilot Wire which is only for communication to an external hard wired programmer if not do not conn
10. rotection It is possible to lock the keyboard to avoid accidental modifications by children Press simultaneously and Prog buttons fig 1 for about 3 seconds to lock the keyboard The key lock icon will be shown on the display fig 1 To unlock the keyboard press simultaneous ly the same two buttons for about 3 seconds once again the key lock icon will disappear from the display fig 1 WARRANTY PURCHASE DETAILS WARRANTY This product includes a free two year warranty valid from the delivery date This warranty covers any miss function that may arise due to the faulty manufacture of the product It does not cover any fault caused by miss use or damage caused by the purchaser or other persons or incorrect installation or non compliance with these instructions after delivery This warranty exclusively covers the repair or replacement free of charge of parts the product or if necessary full product replacement recognized as faulty INTELLI HEAT Ltd cannot be held responsible to undertake disassembly and assembly works or to refund any expenses incurred for such works or for any direct or indirect damage to persons or property due to any miss functioning of the product Please ensure that you keep all documentation and invoice relating to this product as this will be required should you need to use this warranty Thank you for choosing an INTELLI HEAT product and we wish you a lasting and enjoyable use of this product amp IntelliHe
11. s the current time Hours is now flashing use the and buttons to set and then confirm with Prog button fig 2 Minutes is now flashing repeat the same procedure and then confirm by Prog button fig 1 b Setting the program Now an hourly sequence can be set for each day of the week fig 1 Start with the first day select the sequence required by means of the and button fig 1 to choose for each hour between the comfort temperature full bar and the night temperature empty bar See the diagram below fig 2 Press Prog button fig 1 to confirm and repeat the same procedure for every day of the week The weekly program is now set Fig 2 PILOT WIRE PROGRAMMING ANTI TAMPER LOCK Pilot wire Mode This heater can be centrally controlled and programmed as a single unit or combined with an electric heating system that includes several other heaters provided that the other heaters are equipped with a Pilot wire Please note that such hard wired use of the pilot wire requires connecting a wire to and from the pilot wire of each heaters to a central hard wired Pilot Programmer which usually as with our ZoneRay Pilot wire programmer enables individual daily temperatures and timings to be set for up to four zones over a seven day period which is automatically repeated every seven days several heaters can be grouped in each zone This is not recommended for retro fit sys
12. temperature is fixed at 7 C The appliance comes on automatically when the room temperature drops below 7 C We recommend to use this mode when the room is not used for one day or more Press the Prog button until Anti frost icon appears on the display fig 1 Timer Mode 2h The timer mode can be used to heat the room quickly or speed up the drying of towels Press the Prog button fig 1 until 2h is shown on the display The appliance is on at the maximum power for 2 hours regardless of any temperatures set by the user for safety reasons ambient temperatures above 35 C are not allowed by the system so if that temperature is reached the thermostat will switch the unit off The timer mode is set to stop automatically after the 2h period and will then revert to the previous mode If necessary the user can switch back to other modes at any time by simply pressing the Prog button fig 1 Chrono Mode This operating mode allows the user to set different temperatures during the day The Comfort Night temperature and the time intervals can be programmed 8 DAILY WEEKLY PROGRAMMING a Setting the current day and time Press Prog and ON OFF buttons see fig 1 page 7 simultaneously to enter the configura tion mode The arrow indicating the current day fig 1 flashes press and buttons fig 2 to set the current day Then press the Prog button Fig 1 again to confirm Now the display show
13. tems as unless visible trunking of wiring is acceptable such wiring will need to be chased into the walls Alternatively if such centralized programming is preferred our wireless version of ZoneRay is the solution This system simply requires connecting the pilot wire from each heater to a small discrete wall mounted receiver one receiver per heater Programming and control commands can then be achieved as per the Pilot wire system using our wireless version of the ZoneRay central programmer Additionally as opposed to the hard wired version the wireless ZoneRay version enables the individual management of up to six zones Any Pilot wire Programmer used must give commands corresponding to the GIFAM standard Inter professional group of manufacturers of French Electric Household Appliances The programming unit must be able to transmit the following information Comfort no signal ECO lowering by 3 5 plus minus 0 5 K signal complete wave Anti frost at 7 plus minus 3 C negative half wave Stop signal positive half wave The appliance has 2 additional controls comfort 1 C comfort temperature reduced by 1 C and comfort 2 C comfort temperature reduced by 2 C These controls are activated by the power supply company Local Electricity Board and processed by the power manager Check with comfort temperature reduced by whether your electric system is provided with this type of device Child Lock Anti tamper P

Download Pdf Manuals

image

Related Search

Related Contents

Benutzeranleitung europacPRO rugged Bausatz 3 HE / 6 HE User  TRENDnet v.92 PCI MODEM Modem User Manual  Alternativas de análise para um desfecho binário em estudos  VALIDATION-CNIR DES 16 et 17 septembre 2006 UNE  G2A user guideV11.2.2    Medisana RBI  Anti C, Anti c, Anti-E, Anti e Monoclonal Reagents for Saline  Persona P14W - PDi Communication Systems  Untitled - Panacom  