1. Supporting SSH cliant The XSCF supports the below SSH cliants Solaris Secure Shell Open SSH PuTTY TTSSH SSH plug in for Tera Term Pro Host Key Settings For doing the host authentication of XSCF in SSH protocol it explains the method of generating a host key and downloading it to XSCF It is necessary to generate the host key beforehand in the workstation which installed Solaris Secure Shell or Open SSH Generate SSH1 host key and SSH2 host key For information about installing or using Solaris Secure Shell and Open SSH please refer to the manual of each product 2 34 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings To generate the SSH1 host key in the workstation which installed Solaris Secure Shell or Open SSH do the following ssh keygen t rsa Generating public private rsa1 key pair Enter file in which to save the key nome user ssh identity ssh1 key Enter passphrase empty for no passphrase Enter same passphrase again Your identification has been saved in ssh1 key Your public key has been saved in ssh1 key pub The key fingerprint is 90 37 16 e0 cb 67 13 68 61 dce 17 0f 7f 2c 57 b7 user domain The host key is generated without a passphrase The Privete key is downloaded to XSCF and the public key is not downloaded To generate the SSH2 host key in the workstation which installed Solaris Secure Shell or O
2. C2130300 Message UPA frequency expectant value is out of range Explanation UPA clock frequency value is abnorrmal Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 9 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C2130400 Message Pon sequence error sectionXX status YY Explanation A power on sequence error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF 306000n Message THERMAL SENSOR n CPU access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C306020n Message CPU n thermal alarm shutdown xxC Explanation An abnormal temperature was detected on the CPU Replacement part number 11 CPU 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C306030n Message CPU n thermal alarm epoff xxC Explanation An abnormal temperature was detected on the CPU Replacement part number 11 CPU 0 3 Action Replace the CPU Or
3. For information about XSCF operation when login fails see Chapter5 How to Use the XSCF Web Function Operation from a terminal connected to the serial port tty a The following explains how to log in from a terminal connected to the serial port tty a 1 From the console immediately after the port connection input the keyword tilde period it s default value to enter the XSCF console 2 After having entered the XSCF console input the user ID and password that have been registered from the Machine Administration Menu After login to the account the XSCF shell prompt SCF gt appears so use the XSCF commands The following is an example of command execution lt This line is an input operation Not displayed SCF Shel login root Password SCF Version XXXXXXXX ALL RIGHTS RESERVED COPYRIGHT C FUJITSU LIMITED 2003 11 22 333 444 SCF gt Operation for connecting via the SCF LAN telnet The following explains how to log in to the XSCF shell using the SCF LAN telnet 6 4 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1 2 6 2 Login to XSCF User Account Specify the IP address and port number 8010 for the XSCF shell and execute telnet via the SCF LAN On the XSCF console enter the user ID and password After login to the account the XSCF shell prompt SCF gt appears and XSCF commands can be entered Use lan config command to display the configuration
4. 28 OSRUN OS running phase phase 13 BI2 Initialization 2 1D SCSI SCSI probing phase 2A POFF Power off phase phase 14 L1 Initialization 3 1E NET NET probing phase 2B REBOOT Reboot phase phase 15 U2P U2P node phase 1F ATAPI IDE probing phase 2C INITO Init O phase 16 CTIMER Timer node phase 21 USB USB probing phase 2E RED RED WDR XIR phase 17 BEBUS Required ebus 23 CONS Console setting 32 WARNING WARNING node phase phase phase 18 OBPENV About EEPROM 24 SBINF Startupphase 33 AutoBootStop phase AutoBootStop phase 19 EEBUS Ebus node phase 25 BOOTP Boot phase AO Degraded phase by OS 1A CPU CPU node phase 26 BOOTB Boot block phase Table B 1 C POST OBP component Component Component name Component Component name number number 00 01 03 CPU 0 1 4 3 40 41 SCSI 0 SCSI 1 08 0A 0B U2P 0 2 3 42 43 LAN 0 LAN 1 10 12 13 U2P Timer 0 2 3 44 ATAPI 0 20 21 28 PCI 00 01 408 45 USBC 30 DTAG 46 47 USB 0 USB 1 31 SC 50 51 55 PCISERR 32 SCF 60 61 6F SLOT 00 01 15 33 TTY A 80 81 87 SLOT 00 01 02 03 14 15 34 TTY B FO NO_AVAIL_MEM 35 36 38 HPC O 1 3 F1 DIMM_VIOLATION 39 TOD F2 NO_CPU 3A 3B FROM 0 FROM 1 F3 NO_MEMORY 3C SRAM FF 3D PANEL All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 61 B 62 Table B 1 P parts numb
5. Error level report level error detection source Warning 3 XSCF 80809100 Message TOD invalid data Explanation Illegal value is detected on calendar timer Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 80809300 Message NVRAM battery low Explanation Low battery voltage was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8201020n Message PSU n failed Explanation A power supply error power supply remains redundant was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8201050n Message PSU n warning Explanation An alert was detected in a PSU Replacement part number 41 PSU 0 2 Action Replace the PSU Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 2050100 Message NVRAM batter
6. The following table briefly describes each XSCF shell command Table 6 1 XSCF commands Command mite ot Description enesnaniion tO Displays the status of the hardware for items such as e temperature CPU state and power netstatis ro Displays the status of the SCF LAN network for items i such as connection state and data transfer rate Displays the state of each front panel and back panel nodeled r O LED of the server and controls the action of the CHECK LED blinking turning it on and off show status r oO Displays the hardware status show mail report r oO Displays the information of XSCF Mail Administration Displays the information of REMCS Environment Setting show remes mo via XSCF howcomob dadis ro Displays whether console output is controlled by the i serial port tty a or the SCF LAN port Set the output destination of the standard console to the set console device r serial port tty a who r oO who is on the XSCF system show connections r oO Display network connections to XSCF hangup r Kill network connections to XSCF xir r Resets the server CPU shutdown r Shuts down the server por r Performs a system reset for the server request r Initiates an OS dump power off r Powers off the server power on r Powers on the server shauenorioas Lo Toeh ar of errors and information detected by t
7. The port is disabled by default Caution When you use the telnet port 8011 port and 8013 port this port can be used by up to three users per server But the 8011 port 2 connection can be used is used for only the cluster control software when you use the cluster control software The 8013 port is used for only the remote console port When you use the SSH port this port can be used by up to two users per server Access Control of XSCF remote console Specify whether to enable or disable the XSCF Shell port in the XSCF telnet ports or SSH ports When you use the SSH function enable this settings and set up the SSH settings The port is disabled by default Auto disconnect administration _of XSCF remote console Specify minutes of inactivity before automatic log out This function is valid on XSCF shell and XSCF Web function Also specify whether automatic forced logout of XSCF shell is to be enabled or disabled The default timeout is 10 minutes A timeout from 1 to 255 minutes can be specified Note If you set 0 miniutes the automatic logout of XSCF Shell is to be disabled But in this case the automatic logout of XSCF Web function is enable as 10 minutes Note We strongly recommend that you should set the input output destination of the OS console to the tty a Especially when you use the graphic card console to tty a see C
8. 202030n Message DDC A n alarm Explanation A DDC A device error was detected Replacement part number 43 DDC A O Action Replace the DDC A Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C 202040n Message DDC B n alarm Explanation A DDC B device error was detected Replacement part number 44 DDC B O Action Replace the DDC B Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF 202050n Message CPUDDC n alarm Explanation A CPUDDC device error was detected Replacement part number 42 CPUDDC 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF 202060n Message DDC B not mounted Explanation The DDC B is not installed Replacement part number 44 DDC B O Action Install the DDC B Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF 20301FF Message CPU not mounted Explanation The CPU is not installed Replacement part number 11 CPU FF Action Install the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C20302FF Message ALL CPUs are degraded Explanation ALL CPUs degradation was detected Replacement part number 11 CPU FF
9. Detailed code x03mmqq00 Explanation A switch operation event for the remote panel occurred mm indicates the button operation number and qq indicates whether the operation was valid The definition of mm is as follows x01 The POWER switch button was pressed in a normal operation x02 The RESET switch button was pressed in a normal operation x03 The Request switch button was pressed in a normal operation x81 The POWER switch button was pressed for a long time The definition of qq is as follows x01 The operation was valid x02 The operation was not valid C5 RCI Detailed code x01000000 RCI event Explanation Power off request is sent to an IO device Detailed code x02000000 Explanation Switched to be the master of the RCI network B 74 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Detailed code x1000mmnn Explanation The RCI sending event was executed The definition of mm is as follows x00 It was executed except Shutdown x80 Shutdown was executed The definition of nn is as follows x06 Power on was executed x07 Shutdown was executed x08 POR reset was executed x0Oa Panic was occurred _x0b I O Power off was executed Detailed code x20nnnnnn nnnnnnnn nnnnnnnn nnnnnnnn Explanation The RCI receiving event was executed when Power on Shutdown Forced power off or POR reset was executed nn is packet data of RCI c
10. Message FAN CONTROLLER n access error Explanation A system control bus access error bus configuration not redundant was detected Replacement part number 01 SB 00 model 250 R 32 FANJT O 1 FAN 0 3 of model 250 R4 250 P 450 R 450 Q 03 PCI BD 00 FAN 4 7 of model 450 R 450 Q Action For model 250 R Replace the SB For models 250 R4 250 P 450 R 450 Q Replace the SB if fan from 0 to 3 is specified For model 450 Q Replace the PCI board if fan from 4 to 7 is specified Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30E030n Message FAN n alarm xxxxrpm Explanation An abnormal fan speed fan configuration not redundant was detected Replacement part number 31 FAN 0 7 Action Replace the fan Or Do the action of the above FAN CONTROLLER n Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30E050n Message FAN n not mounted Explanation A fan is not installed fan configuration not redundant Replacement part number 31 FAN 0 7 Action Install the missing FAN Or Do the action of the above FAN CONTROLLER n Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C3160300 Message SB serial number is 0 Explanation The SB serial number was all Os Replacement part number 01 SB 00 Action Replace the SB Contact the system adm
11. Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE03050n Message U2P n JTAG status error Explanation A JTAG status timeout was detected Replacement part number 01 SB 00 Action For models 250 R4 250 R 250 P 450 R Replace the SB For model 450 Q Replace the PCI board if U2P 0 s error Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE04000n Message CPU n JTAG ID code error Explanation An ID code error was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF mae Message SC JTAG ID code error Explanation An ID code error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE04020n Message XB n JTAG ID code error Explanation An ID code error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 13 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 CE04030n Message U2P n JTAG ID code error Explanat
12. 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2120200 Message System FATAL Retry out Explanation Retries against fatal error exceeds the limit Replacement part number 01 SB 00 Action Replace the SB or CPU Or for model 450 Q Replace the PCl board Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2120300 Message System RESET Retry out Explanation Retries caused by timeout of system starting up by reset exceeds the limit Replacement part number 01 SB 00 Action Replace the SB or CPU Or for model 450 Q Replace the PCl board Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2120400 Message System PON SEQUENCE Retry out Explanation Retries caused by timeout of system starting up by power on exceeds the limit Replacement part number 01 SB 00 Action Replace the SB or CPU Or for model 450 Q Replace the PCl board Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2130100 Message Unknown SB TYPE XXXXXXXX Explanation The SB type is not supported Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF
13. 2 To establish a SSH connection activate the SSH cliant and specify the IP address of XSCF and port number 22 3 Enter the ID and password 4 Make sure that the terminal becomes the OS console for which input and output are enabled Caution When you use the Standard console via LAN port please set the Standard console to the LAN port by the Console Administration of the Machine Administration Menu Note When you send a Break the break signal is issued to the server Connecting to XSCF via the serial port tty a The following is the procedure for connecting to a terminal via the serial port tty a 1 Make sure that the serial cable is connected to the serial port tty a connector on the rear of the server and connected securely to the PC or workstation 2 Check whether the following are set on the terminal software Baud rate 9600bps Data length 8 bit No parity STOP bit 1 bit No flow control Delay Except for 0 The following is the setting Example All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 1 Connecting Terminals to XSCF Tera Term Serial port setup Port COM Baud rate 9400 Z Data 6 bit M Cancel Parity none x Stop Ibt Help Flow control none Transmit delay f0 msec char 10 msec ine Figure 3 3 Example of setting of terminal software Note Please increase the delay when you cannot connect well 3 On the PC or
14. 2 2 Specifying the XSCF Settings 2 2 7 REMCS Environment Setting via XSCF Specify the REMCS Environment Setting via XSCF This is optional For the settings of REMCS Environment Setting via XSCF you need some settings on the REMCS agent option of the Machine Administration Menu before For about the setting see Machine Administration User s Guide The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration REMCS Administration SSH Administration Table 2 7 REMCS Environment Setting via XSCF Item Description Remarks REMCS via Specify whether to enable or disable the REMCS via XSCF is XSCE setting REMCS function via XSCF disabled by default Server setting Specify the host name or IP address of the No default setting has SMTP server been specified Up to two SMTP servers can be specified In addition you can enable or disable the POP authentication at the same time When you enable the POP authentication specify the host name or IP address of the POP authentication server user ID password the POP waiting time Mailing test After making the settings above you can conduct a mailing test to the REMCS center After then the REMCS center makes a confirmation mail is returned to the administrator After sending a test e mail message confirm that the
15. 3 XSCF 8306010n Message CPU n thermal high warning Explanation High CPU temperature was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 83080100 Message SB FRU data error Explanation An FRU data error on the SB was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830B010n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and IO back panel Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830B0500 Message DDC B xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 44 DDC B O Action Replace the DDC B Or replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 83050907 Message DDC A xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 43 DDC A 0 Action Replace the DDC A Or replace the SB Contact
16. 3 5 How to change the input output destination of OS console to tty a 3 17 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server 3 1 Connecting Terminals to XSCF XSCF offers function to monitor and control the status of the system from terminals connected over LAN and or to serial port tty a This section describes the modes for connecting terminals and the procedure for connecting them to XSCF from a remote console For the initial settings for connection to XSCF see Chapter2 Setting Up XSCF Terminal modes for connecting to XSCF The following figure shows the terminal operating modes for connection to XSCF a telnet connection For serial ot ti a Requirement connect ion on terminal emulator side or a http connect ion You can use vt1l00 that with 600bps 8bit 1 stop bit no parity EAR m Hail report Terminal a Need the cross cable XSCF shell Standard terminal console Router L m telnet connect ion or Ethernet m SSH connect ion Server or m http connect ion Serial port XSCF shell Standard terminal console Connection to serial port Note Only a single standard console can be used via either of the ports y or Enlarged vie port connect To SCF LAN port To serial port Figure 3 1 Operating modes for connection to XSCF Note We strongly recommend that you should set the input output destination of
17. 501013FF 7 Message Illegal SMTP server or mail address specified Explanation An illegal SMTP server or mail address was specified Replacement part number FF FF Action Recheck the SMTP server or mail address Error level report level error detection source Notice 0 XSCF 501020FF P i Message Mail access mode already disable Explanation Mail access mode has been disabled Replacement part number FF FF Action None Error level report level error detection source Notice 0 XSCF 501030FF te Message Illegal name server address specified Explanation An illegal name server address was specified Replacement part number FF FF Action Recheck the name server address Error level report level error detection source Notice 0 XSCF 501031FF Fete the Message Name server initialization failed Explanation Initialization of the name server failed Replacement part number FF FF Action Recheck the name server environment Error level report level error detection source Notice 0 XSCF 501040FF Message SMTP server set by hostname but DNS disable Explanation When the DNS function was disabled the host name of SMTP server was specified Replacement part number FF FF Action Enable the DNS function or specify the IP address of SMTP server in Machine Administration Menu Error level report level error detection source Notice 0 XSCF B 49 All Rights Reserved Copyright C FUJITSU LIM
18. 830B130n 830E000n 8E07200n 8E20F40n C202020n C202050n C2111000 C2111100 C2111200 C2130400 C30B140n C30E010n Alarm C30E010n Warning C30E020n C30E030n C30E040n C30E050n CE20020n and CE20040n are corrected Error codes 41110000 430E060n 46110000 60000100 81110000 86110000 8E208500 8E208600 8E20F700 A0000100 C1110000 C20107FF C6110000 CE209400 CE209500 CE209600 and E0000100 are added Error codes 431608FF 501030FF and 501031FF are deleted In Table parts number U2P Error log for test IO BP POWER BD and PSU CAGE are added Components U2P and U2P Timer numbers are corrected as below 0 3 gt 0 2 43 XSCF Event Log List are corrected Power The definition of Byte1 and Byte2 are corrected In the VV definition x05 A power supply error occurred the definition of Byte1 and Byte2 are added Nodeself In the The sensor failed definition the detail definitions are added Config The bits definition of ss the old unit status is added The term of factor SparcReq is corrected to CPUReq SparcReq In the VV definition Request to SPARC for event is added In the Request to SPARC for shutdown definition descriptions of event code and Detailed code are added Panel In the Operation panel events definition x82 The RESET switch button pressed for a long time is deleted Console RCI The definitions are added These are x10 The RCI sendi
19. Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100180n Message Mail Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF B 51 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6100190n Message Mail name server invalid Explanation Name Resolution of POP server failed The Name server was not specified Replacement part number FF FF Action Specify the Name server Error level report level error detection source Notice 0 XSCF 6100210n Message Mail communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100220n Message Mail authentication of POP server n failed Explanation The authentication failure in POP server n occurred Replacement part number FF FF Action Recheck the POP server name or the POP user name or password Error level report level error detection source Notice 0 XSCF 6100230n Message Mail communication to POP server n f
20. Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C203030n Message Illegal CPU Explanation Unsupported CPU was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Contact the system administrator or a FE Error level report level error detection source Alarm 0 XSCF B 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C2111000 Message Pon sequence timeout sectionXX status YY Explanation A power on sequence timeout was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2111100 Message Poff sequence timeout sectionXX Explanation A power off sequence timeout was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2111200 Message Reset sequence timeout sectionXX status YY Explanation A reset sequence timeout was detected Replacement part number 01 SB 00 Action Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2120100 Message System POWER ON Retry out Explanation OFF ON retries exceeded the limit Replacement part number
21. Alarm 3 XSCF C1001300 Message System hangup OS Level 3 Explanation An interrupt ACK monitoring error was detected while OS was not working Or after an interrupt ACK monitoring error was detected panic and getting information failed Replacement part number FF FF Action Check the Software by the Console log Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C201020n Message PSU n failed Explanation A power supply error power supply not redundant was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and lO back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C201030n Message PSU n PWOK error Explanation An output voltage error was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C2010400 Message PSU mount error Explanation An uninstalled PSU power supply not redundant was detected Replacement part number 41 PSU 0 2 Action Install the missing PSU Or for models
22. Information about operation of the XSCF SNMP agent For a list of standard MIBs supported by XSCF see Appendix C 2 Standard MIB Fujitsu extended MIB In addition to the standard MIB XSCF supports the Fujitsu extended MIB which is an extension for the XSCF SNMP agent The Fujitsu extended MIB primarily manages the following kinds of information Basic information about the server including the serial number Status information about the server including the operating status of the host OS Parts fault information on the server For the list of Fujitsu extended MIBs supported by XSCF see Appendix C 3 Fujitsu Extended MIB Note The MIB file can be refferred to from the following path in the HCP CD too PWPO MIB Next 7 3 About Traps 7 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 7 XSCF SNMP Agent Function 7 3 About Traps The SNMP agent function can send a notification called a trap to the SNMP manager when an event occurs XSCF supports traps in the following cases 1 The XSCF SNMP agent function is started 2 An unauthorized access to the XSCF SNMP agent occurs 3 Apart in the server is faulty 4 The faulty part in the server is repaired by replacement Note In cases of above 3 and 4 the trap target parts are the following Target parts for trap 1 SB PANEL PCI BD SCSI BP CPU SLOT FAN FAN JT PSU CPUDDC DDC A DDC B 1 The parts for w
23. Message Autoboot stop Panel data Error Explanation A boot supression for abnormality of the panel EEPROM data Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 0 0BP B 22 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 330000FF Message Autoboot stop RCI is not configured _ 2 Explanation A boot supression for non configured RCI Replacement part number FF FF Action Please configure the RCI by rci config and rci configio command Contact a FE Error level report level error detection source Alarm 0 OBP FFOOOOFF Message Reset Switch Explanation A CPU reset occurred and logs are recorded Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 3 OBP xx0000FF Message OBP initializing aborted p Explanation Initialization of OBP failed Replacement part number FF FF Action Please follows that when another one is ahead of this message Contact a FE Error level report level error detection source Alarm 0 OBP xx080ayy Message ppp lnstruction Access Error p Explanation An illegal trap error occurred Replacement part number 01 SB 00 or 11 CPU 0 3 or 21 SLOT 00 15 Action Contact a FE Error level report level error detection source Alarm 3 0BP xx0810yy Message ppp lllegal instruction p Explanation An illegal trap e
24. Specify whether to allow sending TRAP IP address allows any IP address SNMP manager in this Specify one IP address for the SNMP community to access the manager XSCF Note however that specifying 0 0 0 0 does not allow traps to be issued Delete community Delete SNMP communities SNMP Administration menu operation In the beginning choose SNMP Administration in XSCF Administration menu of the Machine Administration Menu Examples XSCF Administration 1 Network Configuration 2 User Account Administration 3 Console Configuration 4 XSCF Web Administration 5 SNMP Administration 6 Mail Administration q Quit b Back to previous menu t Go to topmenu h Help Select 1 6 q b t h 5 2 21 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Enable Disable SNMP Next select Enable Disable SNMP in SNMP Administration menu Examples SNMP Administration 1 Show Current Configuration 2 Enable Disable SNMP 3 Management Information 4 Register Community 5 Delete Community q Quit b Back to previous menu t Go to topmenu h Help Select 1 5 q b t h 2 Next Enable Disable SNMP Current Configuration disable 1 Enable SNMP Agent 2 Disable SNMP Agent q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 1 Return Are you sure y n y Return Setting has completed Hit return key SysContact SysName SysLoca
25. VV indicates the detailed event qq change event indicates the inlet temperature pp indicates SB temperature 1 ss indicates SB temperature 2 and jj to mm indicate the temperature of CPUO to CPU3 The definition of VV is as follows x02 A high ambient temperature warning occurred x04 A low ambient temperature warning occurred x06 A high CPU temperature warning occurred x07 Ahigh CPU temperature alarm occurred x12 Recovery from the high ambient temperature warning or low ambient temperature warning was successful x16 Recovery from the CPU temperature warning was successful x20 Fan speed increased x21 Fan speed decreased x30 The PSU cooling Power power off is retried is done by control of the monitoring for foreseeable fault qq indicates the inlet temperature pp indicates PSU number ss mm are ignored Ca SCFshell Detailed code xVV000000 SCF shell Explanation A XSCF shell command issued VV indicates the detailed event event The definition of VV is as follows x00 XSCF exited from maintenance mode _ x01 XSCF entered maintenance mode Cb Powerlog Detailed code xVV000000 Power event Explanation The power event occurred The definition of VV is as follows x01 Power was supplied x10 SCF reset was occurred x11 The SCF entered the Ready state x20 Power on was executed x30 A reset type of reset is XIR was requested x8
26. Windows PCs and ASCII terminals to connect to XSCF through the SCF LAN port The following can be used with SCF LAN Ethernet XSCF shell in a telnet or SSH connection XSCF Web function in a browser SNMP traps Mail reports For more information about the above items see the following chapters Connection to terminals Chapter 3 Connecting XSCF or Server XSCF shells Chapter6 How to Use the XSCF Command Shell XSCF Web function Chapter4 How to Use the Remote Panels and Chapter5 How to Use the XSCF Web Function XSCF SNMP agent function Chapter XSCF SNMP Agent Function XSCF Mail function Chapter 8 XSCF Mail Function XSCF setup Chapter2 Setting Up XSCF Next 1 3 XSCF User Interfaces All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1 3 XSCF User Interfaces 1 3 XSCF User Interfaces XSCEF provides the following user interfaces To use the function to explain as follows the account registration to XSCF is needed Please do the account registration before you start using the XSCF functionality No pre defined account is registered for the security reason In addition we strongly recommend you to register an account for our field engineer hereafter FE during initial set up in consideration of possible future maintenance work by FE XSCF shell 1 Command line interface of XSCF shell that you can use from PC or any other terminal which is connected to XSCF over SCF
27. 00 037 037 037 037 037 037 09 00 037 037 037 037 037 037 10 00 037 037 037 037 037 036 11 00 036 035 035 035 034 034 SCF gt The following table describes the options that can be specified Table 6 8 thermal history command options Option Description Optional The temperature history information is represented graphically If this option is not specified the information is presented in table form When g is specified but value is not specified the command results in an error g Options for value inlet Displays the inlet Displays the temperature history of the CPUs The maximum cpun n 0 1 3 specification is cpu3 Displays the temperature history of SysBoard Up to two locations sb sensorn n 0 1 San be specified Note If the power plug is disconnected all temperature history information will be lost 6 21 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell show ipl logs d t f b s value The show ipl logs command is used to view the message of latest IPL This information can be used to investigate the server status when the system was started The following is an example of command execution SCF gt show ipl logs 0 gt Flash SRAM Test 0 gt Flash Memory check sum Test 0 gt FROM 0 checksum 110a8bf4 0 gt FROM 1 checksum 112e489f 0 gt SRAM Data Line Test 0 gt SRAM
28. 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C20106FF Message PSU configuration error Explanation The number of PSUs is incorrect Replacement part number FF FF Action Check the PSU configuration Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C20107FF Alarm Message PSU type is not proper 0 DC 1 DC 2 AC Explanation The type of PSU is not appropriate Replacement part number FF FF Action Check the PSU configuration Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF 202010n Message DDC Anot mounted Explanation The DDC A is not installed Replacement part number 43 DDC A O Action Install the DDC A Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF ah Message CPUDDC not mounted Explanation The CPUDDC is not installed Replacement part number 42 CPUDDC 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF
29. 36 2 37 3 38 Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP Alarm Warnig Notice All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 43 Table B 1 8 Warning level errors 4 Error code Message and explanation A0000100 Message Check machine administration logs Explanation The failure of parts is detected Replacement part number M Action Check the hardware logs of Machine Administration function Contact a FE Error level report level error detection source Warning 0 Machine Administration E0000100 Message Check machine administration logs Explanation The failure of parts is detected Replacement part number M Action Check the hardware logs of Machine Administration function Contact a FE Error level report level error detection source Warning 0 Machine Administration M About part number refer to Table B 1 P for details Alarm Warnig Notice Information The content of the error messages might be changed because of the function improvement B 44 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Notice The following table lists notice level errors e g errors in which system operation can continue and the actions to be taken To view errors by error code use XSCF Error Code Table in Section B 4 Alarm 1 Alarm 2 Alarm 3 Warnig 1 Warnig 2 W
30. 42040300 Message UPS low battery Explanation Low battery voltage was detected Replacement part number FF FF Action Charge the UPS Or Replace the battery Contact the system administrator or a FE Error level report level error detection source Notice 3 XSCF 42048100 Message AC Power Recovered When the input power source is the AC Type Power Recovered When the input power source is the DC Type Explanation Power was restored Replacement part number FF FF Action Contact the system administrator or a FE Error level report level error detection source Notice 3 or 0 XSCF 430102FF Message FAN speed low CAUSE temperature lower Explanation Because the inlet temperature has decreased and returned to the normal range fan speed has decreased Replacement part number FF FF Action None Error level report level error detection source Notice 0 XSCF 430103FF Message FAN speed high CAUSE temperature higher Explanation Because the inlet temperature was above the normal range fan speed increased Replacement part number FF FF Action Check the environment Error level report level error detection source Notice 0 XSCF 430E060n Message FAN n mounted Explanation A FAN has been mounted Replacement part number 31 FAN 0 7 Action None Error level report level error detection source Notice 0 XSCF 431501FF Message OBP FMEM version cha
31. After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111340n a gt Message REMCS communication to SMTP server n failed Explanation The communication failure to SMTP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 620000FF Message REMCS Agent stopped by REMCS library Explanation REMCS library failure occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 620001FF Message REMCS Agent stopped by REMCS library Explanation REMCS library failure occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 620002FF Message REMCS Agent stopped by REMCS library Explanation REMCS library failure occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 620003FF Message REMCS Agent stopped by REMCS library Explanation REMCS library failure occurred Replacement part number FF FF Action Needs a du
32. Contact a FE Error level report level error detection source Alarm 0 OBP 271000XX Message BOOTOSIdisk label error p Explanation A disk label error was detected BOOTOS OS phase Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 OBP 272000XX Message BOOTOS SCSI error p Explanation A disk boot error was detected BOOTOS OS phase Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 OBP 273000XX Message BOOTOS SCSI I O error p Explanation A disk boot error was detected BOOTOS OS phase Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 OBP 274000XX Message BOOTOS PCI S ERR XX 50 55 Explanation A PCI address parity error occurred BOOTOS OS phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 275000XX Message BOOTOS network error LAN n XX 42 43 Explanation A network boot error occurred BOOTOS OS phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 276000XX Message BOOTOS network error LAN n XX 42 43 Explanation A network boot error occurred BOOTOS OS
33. Error level report level error detection source Notice 3 XSCF eros Message This is a TEST log Explanation A test Alarm level is executed in Machine Administration function Replacement part number FE test FF Action None Error level report level error detection source Notice 3 XSCF cone Message This is a TEST log Explanation A test Alarm level is executed in XSCF shell function Replacement part number FE test FF Action None Error level report level error detection source Notice 3 XSCF x yyyy device address Alarm Warnig Notice B 59 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Table B 1 10 Notice level errors 2 Error code Message and explanation 112200F1 Message Probing memory error Mem config error Explanation Memory configration error was detected Replacement part number FF FF Action Contact a FE Error level report level error detection source Notice 0 POST xxxB0030 Message DTAG Correctable error DTAG p Explanation A DTAG 1 bit error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Notice 0 POST xxxD006n Message UPA Memory Correctable error SLOT n p Explanation A UPA memory 1 bit error was detected Replacement part number 21 SLOT 00 15 Action Contact a FE Error level report level error detection source Notice 0 POS
34. FUJITSU LIMITED 2003 2004 2005 Chapter 8 XSCF Mail Function 8 4 8 6 Setting up the XSCF Mail Function This section explains how to setting up the XSCF mail function The required steps are explained below Each setting is made from the Machine Administration Menu or on the command line of the Machine Administration function For details of the settings see Chapter2 Setting Up XSCF Step 1 Go to Mail Administration option of XSCF Administration menu of the Machine Administration menu Or use to the scfmail 1M command of the Machine Administration function Step 2 Enable the XSCF mail function Step 3 Specify the following information for the XSCF mail settings Specify the host name or the IP address of the SMTP server Specify the host name or the IP address of the POP Authentication server Specify the mail address of the system administrator as the mail destination Specify From information Note If you will specify the host name of the SMTP server or the POP server before STEP 1 the Name server settings is required at the Network Configuration option of XSCF Administration menu in the Machine Administration Menu or at the scfconsole 1M command of the Machine Administration function Step 4 Send test mail Send test mail with using the Machine Administration Menu or the command of the Machine Administration function If the e mail is received by the system admi
35. Function Types of REMCS Center Connection Part of XSCF How to Set up the XSCF REMCS Agent Function Chapter 10 XSCF Firmware Upgrade and Dump Upgrading the XSCF Firmware How to Get XSCF Dump Information and Collect Logs Appendix A Warning And Information Messages Message Types Messages in Each Function Appendix B XSCF Log Information All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 9 5 1 5 2 5 7 5 8 6 1 6 4 6 7 6 16 6 24 6 28 6 32 7 2 7 3 7 5 7 6 7 6 7 8 8 1 8 2 8 4 8 5 8 6 8 7 8 9 8 10 8 11 9 1 9 2 9 4 9 5 9 8 10 1 10 2 10 6 A 1 A 2 A 8 B 1 XSCF Error Log List and Actions XSCF Power Log List XSCF Event Logs List XSCF Error Code Table Appendix C XSCF MIB MIB Object ID Standard MIB Fujitsu Extended MIB TRAP Appendix D Troubleshooting Troubleshooting XSCF and FAQ Troubleshooting the Server While XSCF Is Being Used Glossary All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 2 B 63 B 70 B 77 C 2 C 3 C 7 C 9 Preface About This Manual Purpose This manual describes the system monitor and control facility eXtended System Control Facility or XSCF hereafter used to control monitor operate and service PRIMEPOWER series servers and their systems XSCF may also be referred to as the System Control Facility SCF Audience This manual is intended for users specifically system management maintenance adm
36. LAN ethernet with using telnet or SSH XSCF shell 2 Command line interface of XSCF shell that you can use from PC or any other terminal which is directly connected to XSCF by serial port Standard console 1 Console of the system that you can access from PC or any other terminal which is connected to XSCF over SCF LAN Ethernet with using telnet or SSH Standard console 2 Console of the system that you can access from PC or any other terminal which is directly connected to XSCF by serial port XSCF Web function Graphical user interface of XSCF achieved with help of any Web browser which is connected to XSCF over SCF LAN Ethernet XSCF SNMP agent function SNMP agent in XSCF that you can monitor PRIMEPOWER as a part of large scale network system to which XSCF is connected in conjunction with SNMP manager XSCF mail function Mail report that XSCF can inform the status of PRIMEPOWER to your any mailer such as your PC or your cellular phone over SCF LAN network XSCF allows up to two XSCF shell terminals at the same time when both SCF LAN and serial port are in use In addition XSCF enables multiple XSCF Web sessions The Standard console OS console can be used on either type of connection For information about connection to XSCF consoles see Chapter 3 Connecting XSCF or Server To use these XSCF interfaces users need to log in to XSCF with an XSCF account then enter a password If a user failed
37. LAN n was degraded Explanation An LAN of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP A0900033 Message ttya was degraded Explanation A tty a of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP A0A00034 Message ttyb was degraded Explanation A tty b of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP B0000039 Message TOD was degraded Explanation A TOD of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP B0200032 Message SCFI was degraded Explanation A SCFI of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 0BP B030003d Message SCFI panel was degraded Explanation A SCFI panel of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP B04000XX Message HPC was degraded HPC n Explanation A HPC of the dergadation by OS occurred n XX 0 35 1
38. LIMITED 2003 2004 2005 Chapter1 Overview of XSCF Table 1 2 Functions related to Hardware error log Type Characteristics XSCF function E mail The XSCF mail function can immediately report XSCF mail happend error by sending e mail to defined function addresses of administrators SNMP Using a TRAP the XSCF SNMP agent function XSCF SNMP Manager can immediately report happened error to the agent function administrators located far from systems Time at which the error was trapped Host name XSCF shell You can check the error log information about XSCF shell status of system with using commands on XSCF shell that you can access from terminal connected to XSCF Remote The XSCF Web function graphically displays the XSCF Web panel server status by specify host name of XSCF to a function Web browser Error log States of the LEDs on the operating panel The following error log items are common to these functions Time at which the error occurred local time Message Error code Faulty component Other XSCF logs and their linkage with the XSCF functions In addition to Hardware error log XSCF also stores the following types of logs Access log Records logins to XSCF authentication timeouts and power on off operations on the remote panel Power log Records power on off operations and reset operations to the server Event log Records events which is no
39. OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER iso org 3 dod 6 1 internet 1 internet 2 internet 3 internet 4 mgmt 1 mib 2 1 mib 2 2 mib 2 3 mib 2 4 mib 2 5 mib 2 6 mib 2 7 mib 2 11 private 1 enterprises 211 fujitsu 1 product 15 solaris 2 primepower 1 scfObjects 1 scfObjects 2 scfObjects 3 scfObjects 4 fujitsu 4 application 1 ap Network 3 aplNetFunction 40 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C 2 Standard MIB The tables below explain the Standard MIB MIB _ lists supported by the XSCF 1 system group Table C 1 system group MIB OBJECT ID SYNTAX RW 1 sysDescr system 1 DisplayString R sysObjectID system 2 ObjectID R sysUpTime system 3 TimeTicks R sysContact system 4 DisplayString R sysName system 5 DisplayString R sysLocation system 6 DisplayString R sysServices system 7 INTEGER R 1 R Read Only R W Read Wri
40. POP server To discontinue setting of SMTP server just type in return key Input popy Return Enter the Password of POP server You can make password empty Input XXXXXXXXXX Return Re input XXXXXXXXXX Return Enter the POP Waiting time 500 ms 127500 ms To set default time 1000 ms just type in return key Input Return 2 27 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Next Enable Mail Report and setup 1 To user example com 2 From admin example com 3 SMTP server 1 popy POP server1 smtp server POP User1 popy POP Waiting time1 ms 1000 4 SMTP server 2 u Setup execution q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h u Return Are you sure y n y Setting has completed XSCF will send test mail with new configuration Hit return key Return Test mail sending was requested to XSCF Please check reception of the mail Hit return key Mail address specify multiple addresses seperated by a comma The total number of characters cannot exceed 255 Note Select Show Current Configuration in Mail Administration menu and check whether to have completed the Mail report from XSCF normally If the e mail is not received the mail is sent to the destination for undelivered mail or the error logs is recorded so check them Test Mail Next select Send Test Mail in Mail Administration menu in order to condu
41. Power on suppression messages All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 7 Control execution messages during the monitoring for foreseeable faults The following information message is displayed on the OS console when XSCF does a necessary control during the system monitoring The following example is message for the server cooling the XSCF does the server power off and power on again Start power offfon to cool down system Code 021f0100 Figure A 7 Control execution messages during the monitoring for foreseeable faults Next A 2 Messages in Each Function A 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 A 2 Messages in Each Function This section explains how to read typical messages displayed or logged by each of the XSCF functions Messages output on standard console OS console The following explains typical messages displayed on the standard console OS console when XSCF detects a server error Three examples of messages displayed when an error has been detected or the status is being reported are given below Example 1 Jul 25 17 07 34 JST 2002 XSCF A PSU c2010100 PSU n input failure Example 2 Jul 25 17 07 34 JST 2002 XSCF W SB c5340000 NVRAM CALENDER invalid data Example 3 Jul 25 17 07 34 JST 2002 XSCF 1 02000000 Start power on sequence Each line has the following format Mnn DD hh mm ss XXX YYYY XSCF Z xxxx nnnnnnnn Message Mmh First three lette
42. SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111170n Message REMCS Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111180n i Message REMCS Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111190n Message REMCS name server invalid Explanation Name Resolution of SMTP server failed The Name server was not specified Replacement part number FF FF Action Specify ythe Name server Error level report level error detection source Notice 0 XSCF B 57 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6111210n Message REMCS setting of SMTP server n failed Explanation The setting failure of SMTP server n was detected Replacement part number FF FF Ac
43. The IO node address was duplicated x93 An unregistered node is found x95 The sensor failed When VV is x95 The sensor failed ss is sensor number The definitions of pp are as follows x01 The system control bus switcher x02 SB thermal sensor x03 FAN sensor ss is x00 x04 Inlet sensor x05 CPU thermal sensor 09 Mount Mount error RCI device only Detailed code x01mmqq00 Explanation The number of parts was more than the expected value for the installation conditions mm indicates the part name number and qq indicates the device dependent information The definition of mm is as follows x01 Power supply unit x02 Fan x03 Temperature sensor x04 Battery for memory backup x05 UPS _ x06 Humidity sensor Detailed code x02mmqq00 Explanation The number of parts was less than the expected value for the installation conditions mm indicates the part name number and qq indicates the device dependent information The definition of mm is the same as described above Detailed code x03mmqq00 Explanation The mounting location of the part is different from the correct position mm indicates the part name number and qq indicates the device dependent information The definition of mm is the same as described above 0a Change Status transition event RCI device only Detailed code xVV000000 Explanation A status transition event f
44. These messages are displayed even when no XSCF accounts are registered In case you have faced any problem and you cannot login to XSCF due to any reason such as no XSCF account fix the problem with refering this message Next 6 3 Server Status and Control Commands 6 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 3 6 3 Server Status and Control Commands Server Status and Control Commands The following XSCF commands enable the status of the server to be displayed and the server to be operated and controlled env monitor net status nodeled show status show console device set console device xir por shutdown request power off power on env monitor value The env monitor command is used to view the server status For example it can be used to display the temperature CPU state and power supply state When no options are specified major information is displayed The following is an example of command execution SCF gt env monitor CPU No Temp Status DDC Voltage DDC Status 0 31C 0 K 1 31V 0 K 1 30C 0 K 1 33V 0 K System Board SB TemperatureO 36C Temperature 27C SB 12V 11 99V SB 12V 12 26V SB5V 5 06V SB 3 3V 3 34V SB2 5V 2 65V SB1 8V 1 77V SB1 25V 1 32V FAN 0 rotate state 3660rpm FAN 1 rotate state 3960rpm FAN 2 rotate state 3720rpm FAN 3 rotate state 3960rpm FAN 4 rotate state 4080rpm FAN 5 rotate state 3720rpm PSU 0
45. Tick register error CPU n Explanation A CPU Tick register error was detected Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 142z000n z 0 1 3 Message Stick register error CPU n Explanation A CPU STick register error was detected Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 150z000n z 0 1 2 Message U2P Probe error U2P n Explanation A U2P error was detected n 0 3 Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 151000XX Message U2P Registers error U2P n Explanation A U2P register error was detected n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 151100XX Message U2P Registers error U2P n Explanation A U2P register error was detected n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 152z00XX z 0 1 3 Message U2P Interrupt error yyyyy Explanation Expected interrupt is not detected The definition of yyyy and code XX are as follows U2P 0 3 XX 08 0B U2P Timer 0 3 XX 1 0 13 PCI 0 8 XX 20 28 TTY A
46. administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyyF4 x Message Unknown RCI device was detected XXXXXXXX Explanation An unregistered RCI device was detected Replacement part number A1 FF Action After checking the unregistered device reconstruct the RCI if installation of the device is required Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 870005FF Message SCF LAN IP duplicate Explanation An IP address duplication error was detected Replacement part number FF FF Action Check the LAN environment Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8D000500 Message SCF FMEM bank change error Explanation Bank switching was disabled Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E07200n Message Correct error count over flow Explanation Count of ECC correctable errors detected by the CPU n exceeds the threshold Replacement part number FF FF Action Please check the errors occurred before Then perform it as follow Replace the SLOT memory Or Replace the PCl Card or replace the SB or replace the CPU Contact the system administrator or a FE Error level report level error detection sourc
47. detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 10 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C30BOE0n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30B100n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30B120n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Contact the system administrator or a FE Error level repor
48. example of command execution SCF gt exit logout help value The help command is used to display alphabetically a list of shell commands available in the XSCF shell Detail command information is available when help command is followed by each command name as option The following is an example of command execution SCF gt help COMMAND DESCRIPTION date Show date env moni tor Show system environment exit Exit XSCF Shell help Show help of shell command hangup Kill XSCF telnet connections 6 28 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 an conf ig net status nodeled por power on power off rci conf ig request send break set consol e device set she command show access logs show config show connections show console device show console ogs show error logs show event logs show ipl logs show mai report show panic logs show power logs show remcs show she command show status shutdown thermal history version who Xir SCF gt show shell command 6 6 Other XSCF Commands Show LAN configuration Show SCF LAN status Show and Control Check LED status por Powrer On Reset Power on Power off Show RCI configuration Panic request Send Break Signal to TTYA console Set console device serial lan Change shell keyword Show the access logs Show system configuration Show XSCF connection status Show console device setting as TTYA Port Show console messages Show e
49. external facility Source 17 RCI Host Detailed code x82000000 Explanation Power on was executed by the RCI Host A delayed startup of the system was performed Source 18 HTTP Detailed code x00000000 Explanation Power on was executed via HTTP Source 18 HTTP Detailed code x81000000 Explanation Power on was executed via HTTP An XSCF requests power on of external facility Source 18 HTTP Detailed code x82000000 Explanation Power on was executed via HTTP A delayed startup of the system was performed Source 80 Retry Detailed code x01000000 Explanation A power off or a power on retry was made The retry is caused by FATAL Source 80 Retry Detailed code x02000000 Explanation A power off or a power on retry was made The retry is caused by an alive check error Source 80 Retry Detailed code x03000000 Explanation A power off or a power on retry was retried The retry is caused by a SPARC instruction Source 80 Retry Detailed code x04000000 Explanation A power off or a power on retry was retried The retry is caused by a SCF sequence error Source 80 Retry Detailed code x05000000 Explanation A power off or a power on retry was retried The retry is caused by a firmware update Source 80 Retry Detailed code x06000000 Explanation A power off or a power on retry was retried The retry is caused by for the server cooling 30 XIR Source 00 PANEL SWITCH Detailed code x000
50. front panel Note that you cannot set the mode switch to LOCK UNLOCK or MAINTENANCE on the front remote panel Checking the states of the LEDs You can determine the status of server operation by checking the LEDs Viewing messages The kinds of information listed below are displayed on the remote Panel For information about the logs listed below see Appendix B XSCF Log Information Error log messages Power log messages History of panel messages displayed Next 4 3 LED Indicators on the Remote Panel 4 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 3 LED Indicators on the Remote Panel 4 3 LED Indicators on the Remote Panel The LEDs listed below are mounted on the front panel and back panel shown in Figure 4 1 This section explains of the LED indicators on the remote Panel These indicators have the same meaning as the LED indicators on the operating Panel For details of the LEDs see the User s Manual for the server POWER LED ONLINE LED CHECK LED SCF Ready LED Before checking the LEDs Turning the power on or off or resetting the server from the front remote panel refreshes the XSCF Web browser page at intervals of about 10 seconds If necessary the user must manually refresh the browser page POWER LED The POWER LED on the front remote panel is green when it is on Refresh the Web browser page then check the POWER LED to determine whether server power is on or off While
51. function see Chapter 5 to try to check the error logs Please refer to the method of dealing with this manual appendix B c Please check the XSCF s event log and the server status of by using the XSCF shell via a telnet or a serial port D 9 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Please confirm the event which has happened at time that the problem occurs by using below commands show error logs show event logs show power logs show console logs If you find an error please refer to the method of dealing with this manual appendix B d Check the XSCF console log or panic log for the latest messages The message might be displayed as OS detects the problem About Panic please confirm the event which has happened at time that the problem occurs by using show panic logs command For using the command see Chapter6 How to Use the XSCF Command Shell 10 Please restart the system if you cannot find out any problem in the above mentioned check points 11 If you found any hardware failure take action according to the method written on appendix B such as replace a part with using Machine Administration Menu Next Glossary All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Glossary This appendix is a glossary of XSCF related terms used in this manual ACK An abbreviation of acknowledgement ACK is a positive response transmitted from the sending PC to the receiving PC
52. in communication between PCs It is transmitted for example when a data transfer has ended successfully When all data has been received without error the receiving PC sends an ACK packet Conversely if corrupted data is received the receiving PC requests retransmission ACK timeout The time allowed for an acknowledgement to be sent from the sending PC to the receiving PC APCS Automatic power control The generic term for functions of PRIMEPOWER series machines supported by the Enhanced Support Facility ESF that control power supply schedules ATAPI An abbreviation of AT Attachment Packet Interface A standard made to connect devices other than HDD such as CD ROM with controller IDE Bank An area used when a physical memory is divided into areas for management purposes A bank required for an area specified in the address space is allocated each time it is used The bank must be changed if a different bank is accessed CCU An abbreviation of Console Connection Unit A console connection unit converts the input and output of a serial connected console for the LAN and converts the transmission data from a LAN connected terminal CE An abbreviation of correctable error Checksum A method used to check for corrupted data The data is sent with a sum The receiving end calculates the sum of the received data and compares it with the sum calculated at the sending end Cluster control software This software is a fourth gener
53. information can be viewed for use in investigating circumstances of use when a system error has occurred The same power log information is retained by the Machine Administration Menu For the logging information retained by the Machine Administration Menu see the Machine Administration Guide for the ESF The maximum number of log entries is 32 The following shows the format of a line in the power log DATE TIME TYPE FACTOR DETAIL MSW DATE Date on which the log entry was recorded TIME Time local time at which the entry was recorded TYPE The type of the power event such as power on or reset and the code FACTOR Hardware that instructed the power event and the code DETAIL Details in binary MSW Mode set by the mode switch on the operating panel M MAINTENANCE mode U UNLOCK mode L LOCK mode For a list of power logs and a fuller explanation see Appendix B XSCF Log Information The following is an example of command execution SCF gt show power logs DATE TIME TYPE FACTOR DETAIL MSW 2002 08 07 15 02 58 20 Power on 80 UPS 01 000000 M 2002 08 07 15 03 03 3f Reset Release 00 00 000000 M All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 6 18 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 0
54. information of the SCF LAN The following is an example of command execution SCF Shel login root Password SCF Version XXXXXXXX ALL RIGHTS RESERVED COPYRIGHT C FUJITSU LIMITED 2003 11 22 333 444 SCF gt Operation for connecting via the SCF LAN SSH The following explains how to log in to the XSCF shell using the SCF LAN SSH 1 2 Specify the IP address and port number 8810 for the XSCF shell and execute SSH via the SCF LAN On the XSCF console enter the user ID and password After login to the account the XSCF shell prompt SCF gt appears and XSCF commands can be entered Use lan config command to display the configuration information of the SCF LAN Error Messages Report Function Serial Port Only In case any Alarm or Warning level fault has been detected error messages are displayed following to typing XSCF Shell Keyword on the XSCF seraial port or to log in XSCF shell on 8010 This error messages are displayed on serail port only when the mode switch on the front panel is placed to maintenance position this is NOT applied to error message on XSCF 8010 port Note ae XSCF Parts Error Infomation Parts Error Message cease a erm ene amt CPU 0 CPUDDC O 1 09V expect xx xxV SCF Shel login 6 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell
55. initialization failed Explanation Initialization of the OBP failed BI2 Initialization 2 phase Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 140000FF Message L1 initailization failed Explanation Initialization of the OBP failed L1 Initialization 3 phase Replacement part number FF FF or 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 0 OBP 1500000X Message U2P initailization failed Explanation Initialization of the OBP failed U2P U2P node phase Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1600000X Message CTIMERiinitialization failed Explanation Initialization of the OBP failed CTIMER Timer node phase Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1700000X Message BEBUS Probing Basic ebus device failed Explanation Initialization of the OBP failed BEBUS Required ebus node phase Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1800000X Message OBPENViinitialization failed Explanation Initialization of the OBP failed OBPENV About EEPROM phase Replacement part number 11 CPU 0 3 Action Contact a FE E
56. is displayed while processing it 3 Check the information of setting 0 ok rci config HOST address 000101ff mode 20a0 status 80000000 LIST address status device class sub class 000101ff 98 0001 0a 003001ff 90 0400 05 003002ff 90 0200 02 002007ff 90 0800 01 0 ok device class device type code 3 sub class device type detailed code All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server 1 3 is as follows m1 15 2 31 1 1 bitt 2 bit2 3 bit3 4 bit4 5 bit5 6 bit6 7 bit7 8 bit13 2 9 bit0 3 10 bit29 11 bit31 3 87 O bit m marnm eee CO D OS coh a a on baad 23 15 O bit s ee eee eee the system reset instruction can be received 1 enable to receive the forced power off instruction can be sent 1 enable to send Automatic power on prohibition mode after the forced power off can be set 1 unable to start shutdown instruction can be received 1 enable to receive shutdown instruction can be sent 1 enable to send instruction to turn on power can be received 1 enable to receive instruction to turn on power can be sent 1 enable to send instruction to turn on power can be received from PC I F 1 enable to receive the result of configured RCI 0 normal Excluding 0 abnormal the state of configuring RCI 1 now configuring RCI the state of
57. level error detection source Notice 0 XSCF B 54 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6110110n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110120n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110130n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed POP server n was not found Replacement part number FF FF Action Recheck the POP server Error level report level error detection source Notice 0 XSCF 6110140n Message REMCS communication to name server timeout Explanation Name Resolution of POP server failed The timeout occurred by the Name server Replacement part number FF FF Action Recheck the POP server or the Name server Error level report level error dete
58. others Note There are two user authority levels which are explained below For information about setting the user authority see Chapter2 Setting Up XSCF root Root level authority All XSCF shell commands can be used others Authority other than root level Only some of the XSCF shell commands can be used Next 6 2 Login to XSCF User Account 6 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 6 2 Login to XSCF User Account This section explains how to log in to the XSCF account The available methods are to log in using telnet or SSH from the SCF LAN port and to log in from the serial port tty a Each method is described below Before login Note the following before login For information about registering or adding an account see Chapter2 Setting Up XSCF When the shell has not been accessed for some time after login XSCF automatically terminates the shell The default timeout period is 10 minutes The timeout period can be specified For information about setting the timeout period see Chapter2 Setting Up XSCF For a single server since no more than two terminals can be connected at the same time to the XSCF shell through the serial port tty a and the SCF LAN port no more than two users can operate the XSCF shell at the same time For information about the type of console connection see Chapter 3 Connecting XSCF or Server
59. part number FF FF or 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1BO0000FF Message NVRAMRClinitialization failed Explanation Initialization of the OBP failed NVRAMRC NVRAMRC execution phase Replacement part number FF FF Action Please confirm the description of nvramrc Then contact a FE Error level report level error detection source Alarm 0 OBP 1 00002n Message PCI Probing PCI failed PCl 0n Explanation Trouble occurred while probing the PCI slot PCI PCI probing phase Replacement part number 92 PCI 00 08 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1D00004n Message SCSI Probing PCI failed SCSl n n 0 1 n x 0 1 1 0 Explanation Trouble occurred while probing the SCSI SCSI SCSI probing phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1E0000XX Message NET Probing PCI failed LAN n XX 42 43 Explanation Trouble occurred while probing the LAN NET NET probing phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1F000044 Message ATAPI Probing PCI failed ATAPI Explanation Trouble occurred while probing the IDE ATAPI IDE probing phase Replacement part number 01 SB 00 Action Contact a FE Error level repor
60. replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30B000n Message HARDWARE MONITOR n access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30B020n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30B0600 Message DDC B xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 44 DDC B O Action Replace the DDC B Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30B0A0n Message DDC A n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 43 DDC A O Action Replace the DDC A Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30B0C00 Message DDC C n xx xxV expect xx xxV Explanation An abnormal voltage was
61. report level error detection source Notice 0 XSCF 501046FF Message Illegal POP password specified Explanation An illegal POP password was specified Replacement part number FF FF Action Set the pop password again Error level report level error detection source Notice 0 XSCF 501047FF Message Illegal POP Authentic method specified Explanation An illegal POP Authentication method was specified for a reason related to firmware Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 501048FF Message Illegal SMTP server or POP server specified Explanation An illegal SMTP Server or POP Authentication method was specified for a reason related to firmware Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 501049FF are J Message Destination address is not specified Explanation A destination address was not specified Replacement part number FF FF Action Specify the destination mail address Error level report level error detection source Notice 0 XSCF 501050FF 3 a Message Sender address is not specified Explanation A sender address was not specified Replacement part number FF FF Action Specify the sender address Error level report level error detection source Notice 0
62. system is working the POWER LED is green You can determine the operating status of the server by checking the POWER LED together with the other LEDs ONLINE LED The ONLINE LED on the front remote panel is green when it is on When the server has been turned on the ONLINE LED lights intermittently until the system successfully completes the power on sequence When the server is turned off the ONLINE LED also lights intermittently Like the POWER LED the ONLINE LED is green while system is working You can determine the operating status of the server by checking the ONLINE LED together with the other LEDs CHECK LED The CHECK LED on the front remote panel is amber when it is on The CHECK LED indicates a server error Both the CHECK LED on the operating panel and the one on the front remote panel blink when there is a server error When server operation is normal the CHECK LED is off You can determine the operating status of the server by checking the CHECK LED together with the other LEDs When more than one same type of system is installed in the same area it may be difficult to find out the target system By checking the CHECK LED it will be more easier to find target faulty machine In addition to this by using command on XSCF shell you can change the status of CHECK LED to on or blink And you may easily find target machine even when it does not have any faulty components by check LED The remote Panel can also be used to i
63. the trol panel mode switch are enabled Note To be able to performe switch operations log in XSCF with root level authority s Displays the server status of that moment erver er t 2 Specifying a unit that can be selected displays the status information status for the unit pore Enables the logins to the XSCF Web function pages to be viewed Change of Enables the password of the XSCF account to be changed password Error log Displays the XSCF error log Power log Displays the XSCF power log Message F gt history Displays the remote panel message history The following are sample pages of Web browser All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 5 1 Overview of the XSCF Web Function J hir pletotoat rei dcstapturcoip PRUIMEPOWTR XSCI Microsoft Interset Deplener z alaj x Ge R pm fyote Jos to Hit e e e D Gl Qach ijra Jritoy Lhe Ob dageees E terra ida nide fugias 02 p IO Mepa bore 5 O rere Figure 5 1 Example of Top page mia E FUJITSU Figure 5 2 Example of Index page All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 5 How to Use the XSCF Web Function 2 war Seria D OIDIS COE Mode Fusieu PRIMEPOWERDSO tom Api ay rtp rrreg talus i Clee Rekesh Test mode Pop deste Demo lt lt Log informatie Nan Figure 5 3 Example of Unit status page Information The layout and the content of the window sho
64. the application method see Applying patches of About patches for the Enhanced Support Facility 2 3 and Documentation Errata in the ESF Patches CD ROM Note See Readme file of the patch in Our Site or the ESF Patches CD ROM And please be sure to check HCP version and contents of upgrade When there is necessary related software to apply at the same time you have to apply those patches About the application method see the document of each patches 2 Download the patch file and extract the file to an arbitrary directory in the server which is applied the patch 3 Use the patchadd command and register the patch patchadd 913034 xx Checking installed patches Verifying sufficient filesystem capacity dry run method Installing patch packages Patch number 913034 xx has been successfully installed 10 4 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 10 1 Upgrading the XSCF Firmware See var sadm patch 913034 xx log for details Executing postpatch script COMPLETE Patch packages installed FJSVhcp In this state it is not upgraded yet 4 Display Hardware Control Program HCP Administration menu from the Machine Administration Menu 5 Select HCP File Operation then select Show Register the Registered HCP Copy the firmware from Work Area and register it by the Machine Administration Menu Check whether the registered firmware ver
65. the log entry was recorded Time local time at which the entry was recorded M MAINTENANCE mode U UNLOCK mode L LOCK mode Address Device address FACTOR Event category and code DETAIL Details in binary For the list of event logs and meanings see Appendix B XSCF Log Information The following is an example of command execution SCF gt show event logs DATE Se os TIME MSW 2002 08 08 11 43 59 M Address FACTOR 000F7F00 60 SysInfo 00000000 00000000 00000000 00000000 DETAIL 03 000000 00 000000 00 000000 01 000000 00 000000 00 000000 00 000000 00 000000 00 000000 01 000000 00 000000 00 000000 00 000000 00 000000 00 000000 00 000000 00 000000 00 000000 00 000000 FrP CGS aE i E The same event log For the logging information All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2002 08 SCF gt 6 4 XSCF Log View Command 08 11 43 59 M 000F7F00 04 ExtInfo 00000000 00000000 00000000 00000000 show console logs d t s va ue The show console logs command is used to view the console output logs on the server console A log contains the logging data output from the OS to the console and can be used for investigating usag e conditions for system error or other problem The latest 16 KB of logging information can be viewed The following is SCF gt sho an example of command execution w console logs 100 000000
66. the previous state by returning the FILE cp etc snmp mgr snmpinfo dat etc snmp mgr snmpinfo dat bak H Step 3 Merge XSCF extended MIB file with current MIB file by the command mergeinfo When you face any warning or error messages from mergeinfo go to Step 5 opt SMAW bin mergeinfo primepower_xscf dat H Step 4 If file etc snmp mgr snmpinfo dat is updated and new MIB information is added to the content the installation work is completed 7 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 7 5 Introduce Extended MIB of XSCF to SNMP Manager Step 5 When there is message of this command in the merging work merging has not ended normally Please confirm the manual of WebSysAdmin in detail Example Message example of merging command Here a typical message of the merging command and the action method of the message is shown as follows opt SMAW bin mergeinfo pr imepower_xscf dat opt SMAW bin mer geinfo check_names Duplicate name with different OID s rfcl157Domain 0ID1 1 3 6 1 6 2 1 1 OI1D2 1 3 6 1 3 11 3 1 1 Problem Merging was canceled because the key word Rfc1157Domain of OID 1 3 6 1 3 11 3 1 1 in a new MIB infomation has already been used with OID 1 3 6 1 6 2 1 1 in current MIB infomation Action Please correct the key word of new MIB infomation not to conflict and try the merge of MIB infomation again Before correcting the key word view n
67. the server and immediately reports precise information about failures to the user XSCF logs the types of information listed below For information about error messages see Appendix B XSCF Log Information Initial diagnosis on system startup The system performs a self diagnosis If errors are detected in the diagnosis error messages are generated and displayed Network configuration monitor XSCF monitors the LAN configuration If an error is detected an error message is generated and displayed Monitoring of the power supply fans DC voltage system board memory CPU and other components XSCF monitors the status of each component In an error is detected in a component an error message is generated and displayed Based on the error message the system administrator can easily identify a component that needs to be replaced Temperature monitor XSCF monitors the temperatures of the cabinet and CPU If an abnormal temperature is detected an error message is generated and displayed The error messages make it possible to prevent the server from rising to a higher temperature and to prevent server instability RCI device configuration monitor XSCF monitors RCI devices If an error is detected in an RCI device an error message is generated and displayed Based on the error message the system administrator can immediately identify an error in the RCI device configuration All Rights Reserved Copyright C FUJITSU LIMITED 2003 200
68. was detected Replacement part number A1 FF Action Check the power interface connected to the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C4yyyy5n x Message UPS alarm XXXXXXXX CODE XXXXXXXXX Explanation A UPS error was detected Replacement part number A1 FF Action Check the UPS unit connected to the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C4yyyy6n x Message Thermal alarm XXXXXXXX CODE XXXXXXXX Explanation An abnormal temperature was detected Replacement part number A1 FF Action Improve the environment Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 34 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C4yyyy7n x Message AC alarm XXXXXXXX CODE XXXXXXXXX Explanation Abnormality of power is detected Replacement part number A1 FF Action Check the voltage of power supplied to the system Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C4yyyy8n Message Diag alarm XXXXXXXX CODE XXXXXXXX x Explanation A device specific error was detected Replacement part number A1 FF Action Replace the specified IO devi
69. was detected Replacement part number 04 SCSI BP 0 1 Action Replace the SCSI BP Or for models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 28 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 84yyyy01 x Message FAN xx alarm XXXXXXXX CODE XXXXXXXX Explanation A decrease in fan speed was detected Replacement part number A1 FF Action Replace the fan of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyy02 x Message Power Unit alarm XXXXXXXX CODE XXXXXXXX Explanation A power supply error was detected Replacement part number A1 FF Action Replace the power supply unit of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyy03 x Message Memory backup battery warning XXXXXXXX XX Explanation A memory battery error was detected Replacement part number A1 FF Action Replace the battery of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyy04 x Message Extend power warning XXXXXXXX CODE XXXXXXXX Explanation An extended power interface error wa
70. was reported x84 Resume was reported The definition of qq is as follows x00 Normal _ x01 Abnormal C8 LogAnlyz Detailed code x01qq0000 Hardware log Explanation Hardware log analysis started qq indicates the log category analysis The definition of qq is as follows x01 Analysis was started by the log request _ x02 Fatal error log analysis was started Detailed code x02qq0000 nnnnnnnn Explanation Hardware log analysis finished qq indicates the end code The definition of qq is as follows x01 Normal end nn indicates the latch code _xFF Abnormal end nn indicates the fault detection number Detailed code x03qq0000 nnnnnnnn Explanation XSCF ignores events qq indicates the source and nn indicates the latch code The definition of qq is as follows x01 XSCF does not take a log because it s expected and igonoreable problem x02 XSCF does not take a log because attribute is inconsistent _x03 The bit was disabled because of a receive_latch B 75 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Detailed code x04qqss00 nnnnnnnn Explanation A Resion code was detected qq indicates a priority level from 1 to 99 ss indicates the order of the detected Resion code from 1 to 50 and nn indicates the latch code C9 Tempinfo Detailed code xVVqappss jjkkllmm Temperature Explanation A change in temperature occurred
71. workstation use one of the following procedures Connecting to a terminal dedicated to the XSCF shell 1 To use the XSCF shell terminal enter the keyword which is a tilde plus a period This combination is the default value For changing the keyword see Chapter6 How to Use the XSCF Command Shell 2 Enter the ID and password to start the XSCF shell 3 Make sure that the XSCF shell prompt SCF gt is displayed 4 The XSCF shell can now be used Note Even though the server is off the XSCF shell can be used Connecting to the Standard console OS console 1 Ifthe server is off turn it on to start the OS 2 Make sure that the terminal becomes the OS console for which input and output is enabled immediately after power on Caution When you use the Standard console via serial port tty a please set the Standard console to the serial port by the Console Administration of the Machine Administration Menu The default port when it s shipped from factory is the serial port tty a Note When you send a Break the break signal is issued to the server All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server Switching between XSCF shell and Standard console only for serial port You can switch the purpose of terminal from Standard console to XSCF shell or vice versa This switching is only valid on serial port tty a connection The following is th
72. 00 0 gt Probing U2P 3 0x83 at 106 00000000 0 gt U2P Registers Test 0 gt 100_Status 01000000 MC0Q 2 UPA_Conf i g 00000002 0 gt Testing U2P port_id 80 0 gt 103_Status 01000000 MC0Q 2 UPA_Conf i g 00000002 0 gt Testing U2P port_id 83 0 gt U2P Interrupts Test 0 gt Testing U2P 3 portid 83 inr 20ee o gt Testing U2P 3 portid 83 inr 20ef 0 gt Testing U2P 3 portid 83 inr 20f0 SU sppex Omitted 4x SPARC64 V No Keyboard OpenBoot 3 1 0 16 16384 MB memory instal led Ethernet address 0 e0 0 c4 80 3 Host ID 00000000 SCF gt Table 6 7 show console logs command options Description Description d Display the log with logged date d t t Display the log with logged time Ommitting this opiton display the log only Display the log of specified size Value has to be designated in hexadecimal format Ommitting this option display 8KB size log Maximum 16KB can be show access logs The show access logs command is used to view the logs recording access to the XSCF Web function pages XSCF shell or any other XSCF function Any access to XSCF such as a user check system status on XSCF web or a user uses XSCF shell via serial port tty a or LAN telnet or LAN SSH is logged This information can be used for security purposes to investigate usage conditions for an unauthorized access and to investigate system errors The maximum number of log entries is 42 The following s
73. 00000 Explanation A reset type of reset is XIR was requested from operator panel Source 03 SYSTEM CONSOLE pl Detailed code x00000000 Explanation A reset type is XIR was requested from system console Source 05 CPU Detailed code x00000000 Explanation A reset type of reset is XIR was requested from CPU Source Ob ACK timeout Detailed code x00000000 Explanation A reset type of reset is XIR was requested due to timeout of communication ACK timeout B 65 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Source 11 LAN Detailed code x00000000 Explanation A reset type of reset is XIR was requested via LAN Source 12 TTY Detailed code x00000000 Explanation A reset type of reset is XIR was requested via TTY Source 18 HTTP Detailed code x00000000 Explanation A reset type of reset is XIR was requested via HTTP 38 POR Source 00 PANEL SWITCH Detailed code x00000000 Explanation A reset type of reset is POR was requested from operator panel Source 02 RCI IO Detailed code xXX000000 Explanation A reset type of reset is POR was requested from RCI IO XX indicates the node number of RCI IO which request reset to this system Source 03 SYSTEM CONSOLE pl Detailed code x00000000 Explanation A reset type of reset is POR was requested from system console Source 05 CPU Detailed code x00000000 Explanation A reset type of res
74. 00000 and up C2111000 C2111100 C2111200 C2120100 C2120200 C2120300 C2120400 C2130100 C2130300 C2130400 C3000000 and up C3010000 C3020000 C3030000 C3040000 C3050000 C306000n C306020n C306030n C307000n C3080000 C309000n C30A000n C30B000n C30B020n C30B0600 C30B0A0n C30B0C00 C30BOE0n C30B100n C30B120n C30B140n C30C0000 C30C0100 C30D000n C30D010n C30E010n Alarm C30E010n Warning C30E020n C30E030n C30E040n C30E050n C30F0000 C3100000 and up C 310000n C3160300 C3160400 C3170000 C4000000 and up C4yyyyin C4yyyy2n C4yyyy3n C4yyyy4n C4yyyy5n C4yyyy6n C4yyyy7n C4yyyy8n C4yyyy9n C6000000 and up C6110000 C7000000 and up C7000100 C7000200 C7000300 C7000400 CD000000 and up CD000100 CD000200 CD000300 CD000400 CD000600 CE000000 and up CE01000n CE02000n CE03000n CEO301FF CE030200 CEOQ303FF CE0304FF CE04000n CE040100 CE04020n CE04030n CE07100n CEO080000 CE09000n CEOQA0000 CE200000 and up CE20010n CE20020n CE20040n CE200700 CE200900 CE201000 CE201200 CE201300 CE20150n CE209400 CE209500 CE209600 CE209700 CE209800 CE209900 CE20F10n CE20F200 CE20FB00 D0800000 and up D080000n DF000100 and up DF000100 DF001000 Table B 4 2 POST error code table 02000000and up 020000F2 0300003A 0300003B 0310003C 0320003C 0330003C 04000031 05000000and up 05000032 05010032 0510000n 0511000n 07000031 0701000n 07020030 07030031 070400XX 07060030 0
75. 00000000 Explanation A shutdown was requested from operator panel Source 01 NVRAM TOD Detailed code x00000000 Explanation A shutdown was requested due to NVRAM TOD timer setting B 66 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Source 02 RCI lIO Detailed code xXX000000 Explanation A shutdown was requested from RCI IO XX indicates the node number of RCI IO which request shutdown to this system Source 03 SYSTEM CONSOLE pl Detailed code x00000000 Explanation A shutdown was requested from system console Source 10 RCl synchronize Detailed code xXX000000 Explanation A shutdown was requested to other RCI node XX indicates the node number which is requested the shutdown by this system Source 11 LAN Detailed code x00000000 Explanation A shutdown was requested via LAN Source 12 TTY Detailed code x00000000 Explanation A shutdown was requested via TTY Source 17 RCI Host Detailed code xXX000000 Explanation A shutdown was requested from RCI HOST XX indicates the node number of RCI HOST which request shutdown to this system Source 18 HTTP Detailed code x00000000 Explanation A shutdown was requested via HTTP 41 Shutdown Source 0C UPS ALM Detailed code x01000000 Abnormal Explanation A shutdown was requested because of power failure system The shutdown is informed via UPC Source 0C UPS Detailed code x02000000 E
76. 000002a10001be90 pcipsy pci_intr_wrapper 70 104a8ebc 20e5 1 30000ebefd0 30001859d68 3000182fe10 10 3 00000000102be150 0000000000000000 0000000000000000 0000030000d4fac0 14 7 0000030000b85938 000003000185bef8 0000000000000000 0000030001 85bf20 000002a10001bf50 unix current_thread 44 0 ffffffffffffffff 0 30001830aa0 2a10001fd20 0 10 3 00000000100073dc 000002a10001f061 000000000000000f 000002a10001bf50 14 7 00000000000000b0 0000000010415c08 000000000000000b 000002a10001f910 000002a10001f9b0 unix disp_getwork 40 104244d0 0 10425478 1042d590 0 0 10 3 0000004414001603 0000000000000016 000000000000000a 0000000010009b44 14 7 00000000ff31c424 0000000000000000 0000000000000000 000002410001 f9c0 000002a10001fa60 unix idlet a4 0 0 0 104244d0 1 0 10 3 000000001004616c 0000000000000100 0000000000010000 000002a10010bd20 14 7 0000030001835fc8 0000030000074000 0000030001835ee0 0000030001835ed0 syncing file systems 3 done dumping to dev dsk cOt0d0s1 offset 107610112 100 done 36120 pages dumped compression ratio 8 47 dump succeeded rebooting Saving eeprom done Resetting SCF gt Table 6 10 show panic logs command options Description Description d Display the log with logged date d t t Display the log with logged time Omumitting this opiton display the log only f Display the log starting from the latest f b b Display the log starting from the oldest Ommittin
77. 0000FF are added Error code number is corrected as below xx0B0030 gt xxxB0030 xx0C000n gt xxxC000n xx0D006n gt xxxD006n In Table POST OBP test phase number USB is added XSCF Power Log List are corrected added or deleted Power on In the Retry definition the The retry is caused by for the server cooling is added XSCF Event Log List are corrected Temperature change event A definition of x30 The PSU cooling is done by control of the monitoring for foreseeable fault is added Appendix C XSCF MIB In Table C 9 C 13 and C 14 descriptions are added Summary of Changes in Fifth Edition The current fifth edition of this manual differs from previous edition principally by containing the addition of descriptions about Troubleshooting The fifth edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition Chapter 3 Connecting XSCF or Server In Connecting Terminals to XSCF Not to use the XSCF command to set whether to use a standard console via the serial port tty a or the SCF LAN port but to do by the Machine Administration Menu the description is corrected In Connecting Terminals to XSCF a description of setting of the terminal software on the serial port tty a terminal is added Chapter 5 How to Use the XSCF Web Function In Overview of the XSCF Web Function sample pages of Web brows
78. 00FF 2 Message BOOTPIAIl boot devices failed Explanation An error was detected in all boot devices BOOTP Boot phase1 Replacement part number FF FF Action Please confirm values of the OBP environment variable boot device Then contact a FE Error level report level error detection source Alarm 0 OBP 251000XX Message BOOTP disk label error p Explanation A disk label error was detected BOOTP Boot phase1 Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Please confirm whether Disk specified by OBP environment variable or boot device is boot possible Disk or CDROM Then contact a FE Error level report level error detection source Alarm 3 OBP 252000XX Message BOOTP SCSI error p Explanation A disk boot error was detected BOOTP Boot phase1 Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 OBP 253000XX Message BOOTP SCSI I O error p Explanation A disk boot error was detected BOOTP Boot phase1 Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 OBP 254000XX Message BOOTP PCI S ERR XX 50 55 Explanation A PCI address parity error occurred BOOTP Boot phase1 Replacement part number 01 SB 00 Action Contact a FE E
79. 05 Chapter 2 Setting Up XSCF Note The host key disappears when the system board is replaced When you replace the system board please download the host key again Even if a host key disappears you can use the SSH function by using the temporary host key which is pre configured key in XSCF But the temporary host key is the model common host key so It cannot be said that it is secure Therefore when using the temporary host key it limits only at the time of instaling server or replacing system board Usually we recommend that you shoul download the generated host key by above process In addition the fingerprint of the temporary host key is as below SSH1 fingerprint 7 03 97 36 f0 63 63 54 11 78 48 11 ab 2f 70 9e SSH2 fingerprint 8a 4b 26 91 8f d7 31 c2 8f 20 8e 36 45 d6 70 dd Note The following is a reference of the xscf_dl_sshdata command on the Machine Administration function NAME xscf_dl_sshdata download the key for SSH of XSCF SYNOPSIS opt FJSVmadm sbin xscf_dl_sshdata sett file opt FJSVmadm sbin xscf_dl_sshdata setz2 file opt FJSVmadm sbin xscf_dl_sshdata set1 file set2 file opt FJSVmadm sbin xscf_dl_sshdata clr1 opt FJSVmadm sbin xscf_dl_sshdata clr2 opt FJSVmadm sbin xscf_dl_sshdata status DESCRIPTION The xscf_dl_sshdata command controls the key for SSH of XSCF Registration of key deletion of registration key display of registration key information OPERANDS set1 The key data for SS
80. 4 2005 1 3 Chapter1 Overview of XSCF 1 4 6 Security XSCF logs incorrect accesses and unauthorized access to the system The log can be used to immediately determine the cause of an abnormal system operation Note Status of components informed by XSCF could be different from one which is informed by machine administration menu of ESF While Solaris OS is running some of hardware components such as CPU is managed by Solaris OS And change of some status such as degradation of CPU by Solaris OS may be informed to XSCF only during shutting down or rebooting Therefore different information could be displayed between XSCF and machine administration menu To check the current system status during Solaris OS is running using machine administration menu is recommended Next 1 2 Types of Connection to XSCF All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1 2 Types of Connection to XSCF 1 2 Types of Connection to XSCF This section outlines types of connection to XSCF For more information about each type see the User s Manual for the server XSCF enables access to the server over a serial RS 232C port or from networks connected to SCF LAN Figure 1 1 outlines connection to XSCF a telnet connection m telnet connection or or SSH connect ion SSH connect ion or m http connect ion or m http connect ion Terminal Terminal m Hail SCF LAN notification Ethernet Server S
81. 62000000 andup 620000FF 620001FF 620002FF 620003FF 620004FF 620005FF 620100FF 80000000 and up 80805100 80805400 80805600 80809000 80809100 80809300 81000000 and up 81110000 82000000 and up 8201020n 8201050n 82050100 83000000 and up 830101FF 830104FF 83020100 8306010n 83080100 830B010n 830B0500 830B090n 830BOB00 830B0D0n 830BO0FOn 830B110n 830B130n 830E000n 83100000 and up 8310010n 8310020n 8311000n 8311010n 83120000 84000000 and up 84yyyy01 84yyyy02 84yyyy03 84yyyy04 84yyyy05 84yyyy06 84yyyy07 84yyyy08 84yyyy09 84 F1 84 F2 84 F3 84 F4 86000000 and up 86110000 87000000 and up 870005FF 8D000000 and up 8D000500 8E000000 and up 8E07200n 8E07300n 8E208500 8E208600 8E208700 8E208800 8E208900 8E20FBOn 90800000 and up 9080000n C0800000 and up C0800000 C0800100 C0800200 C0800300 C0800400 C0801000 C0801100 C0801200 C0802000 C0803000 C0803100 C0803200 C0804000 C0804100 C0805000 C0805300 C0806000 C0806100 C0807000 C0807100 C0807200 C0808000 C0808100 C0809200 CO80F000 C1000000 and up C1000100 C1000200 C1001100 C1001200 C1001300 C1002100 C1110000 C2000000 and up C201020n C201030n C2010400 C20106FF C20107FF Alarm All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C20107FF Warning 202010n C202020n C202030n C202040n C202050n C 202060n C20301FF C20302FF C203030n C2040200 C21
82. 68 10 2 3 Host3 192 168 10 3 a Add an Access allowed Host u Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 a u q b t h 3 Return Enter the address of host 3 To clear information just type in return key Input Press the return key here then the screen is updated Next Access Control 1 Host1 192 168 10 1 2 Host2 192 168 10 2 a Add an Access allowed Host u Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select a u q b t h u Return Access control list will be updated Are you sure y n y Return Update was completed Hit return key Setting on the command line The XSCF Web Administration can also be set by using the scfhttp 1M command of the Machine Administration function Use the scfstat 1M command to display the configuration information When you set up the XSCF Web Administration on the command line please perform the scfreset 1M command to reflect the setting For details of these three commands of the Machine Administration function see the command reference in the Machine Administration Guide for the ESF The commands are at ESF2 5 1 or later All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Information The layout and the content of the menu show a sample It might be changed because of the function improvement 2 20 All Rights Reserved Copyright C
83. 70500XX 0710000n 0711000n 0712000n 0713000n 07140031 080000XX 0801000X 0900000n 0910000n 0A00000X 0A1z000X 0C00000X All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 10000000and up 10000030 10010030 10100030 1120006n 1121006n 112200F1 112300F0 120z00XX 140z000n 141z000n 142z000n 15000000and up 150z000n 151000XX 151100XX 152Z00XX 153Z00XX 154z00XX 1560002n 16000039 16100033 162000XX 170v0042 171v0042 172v0042 173v0042 1740004n 17500043 17600044 17700045 17710045 80000000and up 8xx008yy 8xx00Ayy 8xx030yy 8xx032yy 8xx034yy 8xx04Wyy 8xx060yy 8xx063yy 8xx064yy 8xx068yy 8 amp xx06Cyy 8xxTTTyy 90000000and up 9xx008yy 9xx00Ayy 9xx030yy 9xx032yy 9xx034yy 9xx04Wyy 9xx060yy 9xx063yy 9xx064yy 9xx068yy Yxx06Cyy 9xxTTTyy 921032XX 921063XX xx000000and up xxxB0030 xxxC000n xxxD006n Table B 4 3 OBP error code table 10000000and up 1100000n 1108020n 1108050n 1108TT00 120000FF 1300000X 140000FF 1500000X 1600000X 1700000X 1800000X 1810003D 1820003D 190000FF 1A00000n 1A0000FF 1B0000FF 1C00002n 1D00004n 1E0000XX 1F000044 20000000and up 21000045 230000FF 240000FF 250000FF 250000FF 2 251000XX 252000XX 253000XX 254000XX 255000XX 256000XX 25700044 260000FF 261000XX 262000XX 263000XX 264000XX 265000XX 266000XX 270000FF 271000XX 272000XX 273000XX 274000XX 275000XX 276000XX 280000FF 281000FF 2A0000FF 2B0000FF 2C0000FF 2E0000FF 2E1000FF 2E200000 3300003
84. 8 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 2002 08 07 SCF gt show event logs The show event logs command is used to view all event logs that have been created on the server such as those recording operator events and the reporting of events from the OS The information can be viewed to determine the operating status of the server as an aid to investigating a system error and to changing the system configuration information is retained by the Machine Administration Menu retained by the Machine Administration Menu see the Machine Administration Guide for the ESF 15 15 15 15 15 15 15 15 16 16 16 16 16 16 16 16 16 16 17 47 54 10 48 08 50 50 58 01 51 00 20 SCF Reset PSU OFF PSU ON Power on Power on Power of f Power on Reset Re lease PSU OFF Power on Reset Re lease Power off Power on Power on Reset Re lease Power off Power on Reset Re lease Power off The maximum number of log entries is 256 The following shows the format of a line in the power log 00 00 00 80 UPS 40 TTY 40 TTY 40 TTY 00 00 80 UPS 40 TTY 40 TTY 40 TTY 00 40 TTY 40 TTY 40 TTY DATE TIME MSW Address FACTOR DETAIL DATE TIME MSW Mode switch setting on the operating panel Date on which
85. 81000000 Explanation Power on was executed by the NVRAM TOD timer setting An XSCF requests power on of external facility Source 01 NVRAM TOD Detailed code x82000000 Explanation Power on was executed by the NVRAM TOD timer setting A delayed startup of the system was performed Source 02 RCI IO Detailed code xXX000000 Explanation Power on was executed by the RCI IO XX indicates the node number of RCI IO instruction source Source 02 RCI IO Detailed code x81000000 Explanation Power on was executed by the RCI IO An XSCF requests power on of external facility Source 02 RCI lIO Detailed code x82000000 Explanation Power on was executed by the RCI IO A delayed startup of the system was performed Source 03 SYSTEM CONSOLE pl Detailed code x00000000 Explanation Power on was executed from the system console Source 0C UPS Detailed code x01000000 Explanation Power was turned on because of recovery from power failure The power restoration is informed via the UPC Source 0C UPS Detailed code x84000000 Explanation Power on sequence caused by recovery from power failure was proceeding A delayed startup of the system was performed Source 10 RCl synchronize Detailed code xXX000000 Explanation Power on was requested to other RCI node XX indicates the node number which is requested the power on by this system Source 11 LAN Detailed code x00000000 Explanation Pow
86. 9 330000FF 330000FF 2 A0000000and up A000000n A010006n A02000XX A030001n A040002n A050004n A0600044 A07000XX A0900033 A0A00034 B0000000and up B0000039 B0200032 B030003d B04000XX F0000000and up FE0000FF FFOOOOFF xx000000and up XXOOOOFF xx0864yy xx0868yy xx0832yy xx08Qayy xx0810yy Table B 4 4 Machine Administration error code table 60000000 60000200 A0000100 E0000100 Next Appendix C XSCF MIB All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Appendix C XSCF MIB This chapter explains MIB Management Infomation Base that supported by the XSCF SNMP agent function This appendix has the following contents Contents C 1 MIB Object ID C 2 C 2 Standard MIB C 3 C 3 Fujitsu Extended MIB C 7 C 4 TRAP C 9 C 1 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C 1 C 2 MIB Object ID The below explains the MIB object identifier supported by the XSCF internet directory mgmt experimental private mib 2 system interfaces at ip icmp tcp udp snmp enterprises fujitsu product solaris primepower scfObjects scfinfo scfState scfTrapParams scfMonitor application aplNetwork aplNetFunction aplNetSCF Next C 2 Standard MIB OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER OBJECT IDENTIFIER
87. Addr Line Test 0 gt SRAM Data Test 0 gt SRAM Init Test O gt SC Test 0 gt SC init O gt SCF Test 0 gt SCF Test 0 gt CPU Status Test OpenBoot 3 1 0 18 1024 MB memory installed Ethernet address 0 ee 0 dd 88 22 Host ID 11223344 SCF Version 0 1 0000 board RCI is not configured 0 ok SCF gt Table 6 9 show ipl logs command options Description Description d Display the log with logged date d t t Display the log with logged time Ommitting this opiton display the log only f Display the log starting from the latest f b b Display the log starting from the oldest Ommitting this opiton display the log starting from the latest Display the log of specified size Value has to be designated in 5 hexadecimal format Ommitting this option display 8KB size log Maximum 16KB can be show panic logs d t f b s va ue The show panic logs command is used to view the logging information of the last panic The following is an example of command execution All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 4 XSCF Log View Command SCF gt show panic logs panic cpu0 thread 2a10001fd20 memory dumping due to pressing REQUEST switch 000002a10001bdeO FUSVpanel panel_intr 58 30000d356c0 30000b85998 1 3 30000d39e08 10078834 10 3 0000030000b859a0 0000000000009b44 0000000000000000 0000030000d39e14 14 7 0000030000b85938 000003000185bef8 0000000000000000 0000030001 85bf20
88. An abnormal voltage1 PSU x02 An abnormal voltage2 PSU x03 An abnormal voltage3 PSU x04 An abnormal voltage4 DDC B x05 An abnormal voltage5 DDC A x06 An abnormal voltage6 DDC C x07 An abnormal voltage7 CPUDDC x08 An abnormal voltage8 PSU The definition of yy is as follows x1m PSU mis PSU number from 0 to 2 x2m CPUDDC mis CPUDDC number from 0 to 3 x30 DDC A x40 DDC B x50 DDC C When VV is x05 A power supply error occurred yy is x1m and mis PSU number from 0 to 2 The definitions of nn are as follows x80 Not mounted x40 Alarm level error x20 Warning level error 03 NVRAM Detailed code x02000000 Battery error Explanation A low voltage error occurred el 04 EXTInfo Detailed code xVVpppp00d External Explanation An external power supply interface error RCI device only occurred power supply VV indicates the detailed event and pppp indicates the unit dependent interface error information RCI device The definition of VV is as follows only x01 An error occurred at the interface with the EDPC el x02 An error occurred at the interface with the EPC 05 UPS Detailed code xVVnn0000 UPS error el Explanation A UPS error occurred VV indicates the detailed event and nn indicates the UPS number The definition of VV is as follows x01 The UPS battery voltage is
89. An illegal interruption was detected p Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx063yy Message ECC_error zzz 9xx063yy Explanation A UE of cache and memory was detected p Replacement part number 11 CPU 0 3 or 21 SLOT 00 15 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx064yy Message fast_instruction_access_mmu_miss CPU n 9xx064yy Explanation An instruction access mmu miss was detected p Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 41 8xx068yy 9xx068yy p Message fast_data_access_mmu_miss CPU n Explanation A data access mmu miss was detected Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx06Cyy 9xx06Cyy p Message fast_data_access_protection CPU n Explanation A data protection exception was detected Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xxTTTyy 9xxTTTyy p Message Trap name CPU n Explanation Any other trap which is not described above is detected Replacement part number 11 CPU 0 3 Action Contact
90. C FUJITSU LIMITED 2003 2004 2005 8 1 Overview of XSCF Mail Function The XSCF mail function has the following features Reporting server parts faults by e mail to the system administrator Reporting an SCF LAN authentication failure by e mail to the system administrator Mail server SMTP server POP aunthentication server wa Aunthen Via SMTP server tication E nE IZE naa Internet 1y Mail terminal Server Parts fault KSCF Unauthorized access Figure 8 1 1 Outline of XSCF mail function The following is the e mail notification method Setting is performed from the Machine Administration Menu or on the command line of the Machine Administration function Sending e mail via the SMTP server The host name or the IP address of the SMTP server must be specified Sending e mail with POP authentication The host name or the IP address of the POP authentication server must be specified Then ID and password for the authentication is required Note When you specify the SMTP server and the POP authentication server the Name server settings is required After the mail settings test mails are sent automatically When the test mail is completed the Mail sending function becomes an enable Please refer to Show Current Configuration of Mail Administration otion of the Machine Administration Menu or refer to mail option of the scfstat 1M command of the Machine Administration function whether to have complet
91. CF Web function has a menu to display logs When you find any abnormality on XSCF Web such as the CHECK LED on the remote panel blinks you may want to check the log By selecting a log on XSCF Web you can see system message and error message with detail information Messages output to the XSCF shell terminal When the user logs in to XSCF from a terminal that can use the XSCF shell messages are displayed on the initial screen When the CHECK LED on the operator panel and remote panel blinks or a server error is recognized on the standard console OS console the XSCF show error logs command can be used to display system messages and error massages together with other specific messages For display examples and more information about the initial message and XSCF command messages see Chapter6 How to Use the XSCF Command Shell and Appendix B XSCF Log Information Next Appendix B XSCF Log Information A 9 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Appendix B XSCF Log Information Appendix B describes the following XSCF log information which can be viewed on the XSCF console using XSCF commands Error logs viewed with the show error logs command Power logs viewed with the show power logs command Event logs viewed with the show event logs command This appendix has the following contents Contents B 1 XSCF Error Log
92. Circled items 1 to 3 above are the same as in the previous sections 4 Time at which the test mail was sent The time is the local time Next 8 8 Contents of Suspension Mail Notification All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 8 8 Contents of Suspension Mail Notification 8 8 Contents of Suspension Mail Notification If it has some events in XSCF or the status of SMTP server and network is not normal the notification of XSCF E mail might be suspended This section explains the contents of the e mail sent when the Mail reporting was suspended Date Mon 02 Jun 2003 14 03 16 0900 D From XSCF lt root host name domain name com gt sil To mail address smtp domain name com D Subject host name XSCF I MAIL SCF Notification MAIL REPORT SUSPENDED X Mailer COS X maitversion 1 0 MINE Version 1 0 3 Content Transfer Encoding fbit Content Type text plain char set US ASCII Content Length 145 Jun 02 14 03 16 host name XSCF Notification MAIL REPORT SUSPENDED Model Name Fujitsu PRIMEPOWER450 PWOLBS111 System Serial No 123456789 000123 Error Parts Detail LOG Mail report was suspended by some factors Please examine the machine System Damage Level Figure 8 7 Mail reporting suspension Circled items 1 to 3 above are the same as in the previous section Next Appendix 9 XSCF REMCS Agent Function 8 11 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Ch
93. Configuration 1 2 3 4 5 6 u q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 1 Return Enter IP Address 192 168 1 10 IP Address 0 0 0 0 Subnet Mask 0 0 0 0 Gateway Address 0 0 0 0 XSCF Host Name Name Server1 Name Server2 Save Configuration Subnet Mask Choose Subnet Mask in Network Configuration menu by number Examples Network Configuration IP Address 192 168 1 10 Subnet Mask 0 0 0 0 Gateway Address 0 0 0 0 XSCF Host Name Name Server1 Name Server2 Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 2 Return Enter Subnet Mask 255 255 255 0 Gateway Address Choose Gateway Address in Network Configuration menu by number Examples 2 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Network Configuration IP Address 192 168 1 10 Subnet Mask 255 255 255 0 Gateway Address 0 0 0 0 XSCF Host Name Name Server Name Server2 Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 3 Return Enter Gateway Address 192 168 1 1 XSCF Host Name Next choose Host Name Configuration in Network Configuration menu by number Examples Network Configuration 1 IP Address 192 168 1 10 Subnet Mask 255 255 255 0 Gateway Address 192 168 1 1 XSCF Host Name Name S
94. Console can NOT be set to LAN port using this command Please use the Machine Administration Menu to set the Standard Console to LAN port who The who command can list the user s name terminal line and login time The following is an example of command execution SCF gt who 6 12 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 3 Server Status and Control Commands plato Serial RS232C 2002 12 03 02 20 14 root Telnet port 8010 2002 12 03 02 13 27 11 22 333 444 SCF gt show connections The show connections command is used to view the XSCF port number and client information such as IP address and port number The following is an example of command execution SCF gt show connect ions XSCF Telnet SSH Active Connections Local Port Foreign Address eee pre een Lemon Oe en 22 10 12 123 4 54456 8810 10 12 123 4 54508 SCF gt hangup The hangup command is used to kill the connections to XSCF The required authority for this command is root level The following table describes the options that can be specified Table 6 5 hangup command options Option Description 22 Disconnect port 22 SSH RW 23 Disconnect port 23 telnet RW 8010 Disconnect port 8010 telnet XSCF shell port 8011 Disconnect all of port 8011 telnet RO port If two users are using both are disconnected 8810 Disconnect port 8810 SSH XSCF shell port 8811 Disconnect port 8811 SSH RO por
95. E Error level report level error detection source Warning 3 POST All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 37 0801000X Message Timer1 increment error U2P Timer X Explanation There is no U2P timer which can be used Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 0900000n Message Tick Stick error CPU n Explanation A Tick error was detected Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0910000n Message Tick Stick error CPU n Explanation A Stick error was detected Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0A00000X Message MMU Registers error CPU X Explanation A compare error was detected in MMU Registers Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0A1z000X z 0 1 3 Message MMU TLBs error CPU X Explanation A compare error was detected in MMU TLBs Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0C00000X Message CPU type check error CPU X Explanation A cache size error was detected in CPUs Replacement part number 11 CPU 0 3 A
96. F The reset state was released x40 A shutdown was requested x41 A shutdown was requested Abnormal system x42 Power off was executed x50 Input power source failure occurred el For the events indicated by Source codes X01 to X08 because RCI specific data is displayed when the source of the event is the RCI device the displayed data does not match the definition shown in the table note About Source codes X01 to X3f X80 is added to those codes when A shutdown request is executed 01 FAN 02 Power 03 NVRAM 04 External 05 UPS 06 Thermal 07 PDOWN 08 Nodeself 09 Mount Oa Change 60 SysInfo 61 Panic 62 Config 71 DevState CO Console C1 Access C2 Author C3 CPUReq C4 Panel C5 RCI C6 Setup C7 EXTInfo C8 LogAnlyz C9 Tempinfo Ca SCFshell Cb Powerlog Information The content of the event logs might be changed because of the function improvement Next B 4 XSCF Error Code Table B 76 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 4 XSCF Error Code Table The table below lists the error codes that appear in error logs displayed when the show error logs command is executed Clicking a code enables you to jump to an explanation of the appropriate log For the error logs list see XSCF Error Log List and Actions in Section B 1 Table B 4 1 XSCF error code table 40000000 and up 408055FF 41000000 and up 41100000 41100100 41110000 42000000 and up 4201010n Al
97. F Shell Error Messages When an XSCF shell command is used incorrectly an error message is displayed following table lists the error messages displayed and explains their meaning Table 6 13 Shell error messages The Error message meaning Syntax Error The syntax of the input command is incorrect Wrong name of Command The command name is incorrect Wrong name of Register The register name is incorrect Parameter Error The parameter is incorrect Invalid option Ustad Sica invalid Impossible mounting Unmounted The requested part has not been mounted Permission denied The requested command is not permitted Aborted The requested command is aborted by user Next Chapter XSCF SNMP Agent Function 6 32 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 7 XSCF SNMP Agent Function Thi s chapter describes the XSCF SNMP agent function This chapter has the following contents Co 7 1 7 2 7 3 7 4 7 5 ntents Summary of XSCF SNMP Agent Function About MIB About Traps How to Set up the XSCF SNMP Agent Function Introduce Extended MIB of XSCF to SNMP Manager 7 5 1 Installation case to WebSysAdmin 7 5 2 _Installation case to SystemWalker All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 7 2 7 3 7 4 7 5 7 6 7 6 7 8 7 1 Chapter 7 XSCF SNMP Agent Function 7 1 Summary of XSCF SNMP Agent Function The XSCF supports the Simple Network Ma
98. FJSVmadm scfshkey set lt keyword gt DESCRIPTION The scfshkey command displays and changes the login keyword to move the control from the standard console to the XSCF shell OPTION set lt keyword gt specifies a new keyword The lt keyword gt specifies a string which consists of alphabetic numeric or special character Its length is 1 7 characters When the OPTION is ommited scfshkey displays the current value of the login keyword EXIT STATUS The following status is returned 0 normal end gt 0 an error occurred logtestLa arm warnning notice The logtest command is used to generate the test error After executing this command you can get the error logs of the specified option level At the same time you can receive the e mail to the pre configured mail address You can check whether to have been set correctly by using this command after setting up XSCF function The required authority for this command is root level The error information can be seen from the following You are able to display the erro logs in the Machine Administration Menu You are able to display the error losgs by using show error logs command in the XSCF Shell You are able to display the error losgs in the XSCF Web function You are able to display the error information in the MIB file You are able to display the error information in the received e Mail Sending by XSCF Mail function You are able to di
99. FUJITSU LIMITED 2003 2004 2005 2 2 5 2 2 Specifying the XSCF Settings SNMP Administration To use the XSCF SNMP agent function specify settings related to the SNMP protocol These settings are optional The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration REMCS Administration SSH Administration Table 2 5 XSCF SNMP Administration Item Description Remarks Enable Disable SNMP Specify whether to enable or disable the SNMP The SNMP agent function agent function is disabled by default If you enable it be sure to specify at least one community Manage SysContact Specify the name of the administrator No default setting has ment Use up to 15 ASCII characters been specified SysName Specify the name of the system No default setting has Infor Use up to 15 ASCII characters been specified mation SysLocation Specify the location of the system No default setting has Use up to 15 ASCII characters been specified Register community Specify SNMP communities One or two Use up to 11 characters to Up to two communities communities can be specified Specify the specify a community following properties name Community name No default IP address has A community name beginning with a space is been specified invalid Note Trap request Specifying 0 0 0 0 as the
100. H Version1 specified by file is registered to XSCF It is necessary to contain extension key in the file name It is possible to specify this option simultaneously with the set2 option set2 The key data for SSH Version2 specified by file is registered to XSCF It is necessary to contain extension key in the file name It is possible to specify this option simultaneously with the set1 option clr1 The key data for SSH Version1 registered in XSCF are deleted It is impossible to specify this option simultaneously with the clr2 option clr2 The key data for SSH Version2 registered in XSCF are deleted It is impossible to specify this option simultaneously with the clr1 option status Information of the key data for SSH registered in XSCF is displayed EXAMPLES 2 36 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Download of the key data for SSH opt FJSVhwr sbin xscf_dl_sshdata set1 xxxxx key set2 yyyyy key Deletion of the key data for SSH Version1 opt FJSVhwr sbin xscf_dl_sshdata clr1 Deletion of the key data for SSH Version2 opt FJSVhwr sbin xscf_dl_sshdata clr2 Display of information on key data opt FJSVhwr sbin xscf_dl_sshdata status TYPE FILE SIZE TIME SSH1 xxxxx key 1000byte Wed May 28 19 30 30 JST 2003 SSH2 yyyyy key 500byte Wed May 28 19 30 30 JST 2003 NOTE Only the super user can execute this command The file name is
101. IMITED 2003 2004 2005 4 2 How to Use the Remote Panel 2 The ONLINE LED on the front panel blinks when the power on sequence has been successfully completed When you turn off the server power the following events occur 1 The ONLINE LED on the front panel starts blinking immediately 2 Only the SCF Ready LED remains on The other LEDs go off when the power off sequence is completed successfully However there is a possibility that POWER LED does not go off at once according to the setting Moreover there is a case that the Check LED keep blinking when the trouble has already been found in the server Note Whenever you control the power from the front remote panel the Web browser window is refreshed at intervals of about 10 seconds If you cannot power the server on or off using the power switch do the following 1 Confirm that the SCF Ready LED on the back panel is green Reset switch Press the reset switch button on the front remote panel to reset the server To be able to performe this switch operation set Enable with read write mode and log in XSCF with root level authority When you click the reset switch button the following events occur 1 The ONLINE LED on the front panel blinks 2 The ONLINE LED on the front panel lights as soon as the reset sequence is completed successfully Note The reset switch resets the system Therefore pushing the reset switch is prohibited for usual operation Please pus
102. ITED 2003 2004 2005 501041FF Message POP server not specified Explanation When the POP Authentication Function was enabled the pop server was not specified Replacement part number FF FF Action Specify the POP server in Machine Administration Menu Error level report level error detection source Notice 0 XSCF 501042FF Message POP server set by hostname but DNS disable Explanation When the DNS function was disabled the host name of POP server was specified Replacement part number FF FF Action Enable the DNS function or specify the IP address of POP server in Machine Administration Menu Error level report level error detection source Notice 0 XSCF 501043FF Message Illegal POP server specified Explanation An illegal POP server was specified Replacement part number FF FF Action Recheck the POP server name Error level report level error detection source Notice 0 XSCF 501044FF Message POP user name not specified Explanation When the POP Authentication Function was enabled the pop user name was not specified Replacement part number FF FF Action Specify the POP user name in Machine Administration Menu Error level report level error detection source Notice 0 XSCF 501045FF Message Illegal POP user name specified Explanation An illegal POP user name was specified Replacement part number FF FF Action Recheck the pop user name Error level
103. JTAG compare error Explanation A setting data compare error was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE03000n Message CPU n JTAG status error Explanation A JTAG status timeout was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE0301FF Message CPU JTAG status error Explanation A JTAG status timeout was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE030200 Message SC JTAG status error Explanation A JTAG status timeout was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF FEPANAEE Message XB 0 2 JTAG status error Explanation A JTAG status timeout was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE0304FF Message XB 3 5 JTAG status error Explanation A JTAG status timeout was detected
104. LIMITED 2003 2004 2005 machine_name Other shell vi OpenBoot PROM ok About model name When this manual describes the PRIMEPOWER model name it uses the nemonic name as follow Table P 3 Model name and Mnemonic Model name Mnemonic PRIMEPOWER250 Rackmount Type 2U 250 R PRIMEPOWER250 Rackmount Type 4U 250 R4 PRIMEPOWER250 Pedestal Type 250 P PRIMEPOWER450 Rackmount Type 4U 450 R PRIMEPOWER450 Rackmount Type 7U 450 Q For the model name of which the input power source is the DC Type see the User s Manual for the server Caution The following function will be supported at HCP version 0501 or later Please ask Sales Department the obtaining method in Chapter2 and Chapter8 on first edition of this manual the menu of Name server configuration in Machine Administration Menu was not exist at HCP version 0201 or before But now it is suppoted On the Menu this enabled you to specify the host name not only IP address of SMTP server Also you can specify the host name of POP server which is enabed at HCP vertsion 0501 For more information about it see Chapter2 Setting Up XSCF About The DNS function in case of using XSCF Mail function Sending method with MX record but SMTP server not used we have said that it will be to support at HCP version 0201 or later in first edition Revision1 of this manual However we do not support because of the following reason
105. List and Actions B 2 B 2 XSCF Power Logs List B 63 B 3 XSCF Event Logs List B 70 B 4 XSCF Error Code Table B 77 B 1 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 1 XSCF Error Log List and Actions This section lists all error log information displayed when the show error logs command is executed on the XSCF console The table below explains the items in the error log list For information about a command to display logs and options to the command see Chapter6 How to Use the XSCF Command Shell To view logs by error code use XSCF Error Code Table in Section B 4 Table B 1 1 How to read the error log list Error code Unique hexadecimal number identifying the error Message Error message Explanation Explains the meaning of the message Indicates the part to be replacement and its part number Examples Replacement When FF FF described replacement part cannot specified part number When 41 PSU 0 2 described category number is 41 and replacement part is PSU and Number is 0 to 2 Please refer to Table B 1 P about parts number Action Action to be taken Error level Shows a level that indicates the extent of the effects of the error on the system The following three error levels are reported A Alarm Fatal problem for system The system cannot continue operation EPOFF Emergency power off STOP Emergency shutdown UNABLE TO START The system could not be started Co
106. Mount Status Alarm All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 7 Chapter 6 How to Use the XSCF Command Shell PSU 1 Mount Status 0 K Mode Switch Status Lock SCF gt The following table describes the options that can be specified Table 6 2 env monitor command options Option value Description no option Displays major status of the machine network Displays the GatewayIP Subnetmask Host name IPaddress and SCF MacAddress information Displays the CPU status DDC status running days error messages m CPU temperature CPU frequency and DDC 1 2 V voltage value for cpun n 0 1 3 each CPU When n is omitted information for all CPUs is displayed Displays the SysBoard status running days error messages SB sb temperature DDC 1 25 V voltage value system clock frequency and SB type information panel Displays the status running days and error messages for the operator panel pcibd Displays the PCI board status running days and error messages scsibpn n 0 1 Displays the status running days and error messages for each SCSI board psun n 0 1 2 Displays the status running days and error messages for each PSU slotn n 0 1 15 Displays the status and error messages for each slot DIMM fann n 0 1 7 Displays the status rotation speed rpm rotation status high low and error messages for each fan ddcan n 0 Displays t
107. PE AREAN Message DTAG correctable error xxxxxxxx Explanation A DTAG error was corrected by the hardware Replacement part number 01 SB 00 Action None Error level report level error detection source Notice 0 XSCF B 47 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4E20F00n Message Processor detected error xxxxxxxx Explanation A CPU detected error Replacement part number 11 CPU 0 3 Action Please follow the message of OS or POST OBP Error level report level error detection source Notice 0 XSCF gEcOE Don Message Correct error Internal xxxxxxxx Explanation An error happened inside of CPU was corrected by the hardware Replacement part number 11 CPU 0 3 Action Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF EENES Message Correct error Outside XXXXXXXX Explanation An error external to the CPU was corrected by the hardware Replacement part number 01 SB 00 Action Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF Sete Message SNMP Agent already started Explanation The SNMP agent function has already started Replacement part number FF FF Action None Error level report level error detection source Notice 0 XSCF PLINER Message SNMP Agent already stopped Explanation The SNMP agent function has already stopped Repla
108. RCI operation 1 active 0001 Server 0200 Power controller 0400 Disk file unit 0800 Line switch device All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 5 How to change the input output destination of OS console to tty a 3 5 How to change the input output destination of OS console to tty a It describes how to change the input output destination of the OS console to the tty a tty a should be used as console to access console via SCF LAN or serial port tty a In addition to this ipl log and panic log which is collected by XSCF is availabe only when output of console is tty a To enable XSCF as the Standard console OS console device you must do the following operation from 1 to 3 Note When you use the graphic card we strongly recommend that you should do as below 1 Changing the environment variable properties of NVRAM 1 Change the MAINTENANCE mode on the MODE SWITCH of the server operation panel 2 Power on the server and enter the following commands at the ok prompt on the Console ok setenv input device ttya ok setenv output device ttya 3 Enter the following command and check the information as below ok printenv input device ttya output device ttya 4 These properties take effect after the next server reset 5 After completing the OBP setting set the MODE switch back to the setting for normal operation LOCK Caution The break signal becomes an enable when
109. SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0801000 Message SYSTEM CONTROL BUS data transfer error Explanation A data transfer error was detected on the system control bus Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0801100 Message SYSTEM CONTROL BUS data transfer timeout error Explanation A data transfer timeout was detected on the system control bus Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 4 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C0801200 Message SYSTEM CONTROL BUS data transfer incomplete Explanation A data transfer interrupt was detected on the system control bus Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0802000 Message TOD NVRAM compere error Explanation A compare error was detected in NVRAM TOD Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0803000 Message SCF SDRAM compare error Exp
110. SCF Subnet Mask Specify the Subnet mask shell and a standard Gateway Address Specify the Default gateway console are disconnected immediately after the setting Please login again and continue the setting XSCF Host Specify the Name Sever Note Name The character which can be specified is Alphanumeric character a z A Z 0 9 hyphen and period Name Server Specify the Name server No default setting has Up to two Name servers can be specified been specified Note When you disable the Name server you should change the following parameters to IP address SMTP server POP server For the settings see the sections of Mail Administration and REMCS Environment Setting via XSCF Network configuration menu operation In the beginning set up Network Configuration in XSCF Administration menu of the Machine Administration Menu Examples 2 4 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings eXtended System Control Facility XSCF Administration XSCF Administration hereafter 1 Network Configuration 2 User Account Administration 3 Console Administration 4 XSCF Web Administration 5 SNMP Administration 6 Mail Administration q Quit b Back to previous menu t Go to topmenu h Help Select 1 6 q b t h 1 IP Address Choose IP Address in Network Configuration menu by number Examples Network
111. SCF shell terminal tty a The XSCF shell can be used by entering a keyword for XSCF Screen switching to and from the standard console can be done Note After login if the XSCF shell has not been accessed for a predetermined time the user is forcibly logged out Standard console Note OS console input and output is enabled Note Please set the however that the standard console cannot use the Standard console to XSCF shell in a telnet connection the serial port by Screen switching to and from the standard console the Console can be done Administration of the Machine Administration Menu The default port when its shipped from factory is the serial port tty a Note For a single server since no more than a total of two terminals can be connected at the same time to the XSCF shell via the serial port tty a and the LAN port only two users can use the XSCF shell at the same time Caution When using the XSCF shell simultaneously on the LAN port and serial port note the following if different power or reset instructions are received from the ports the previous operation such as power off after power on may be canceled Connecting to XSCF using telnet via the LAN port The procedure described in this section assumes that the XSCF initial settings described in Chapter2 Setting Up XSCF have been completed For the connections between XSCF and PC workstation with LAN ca
112. SVmadm sbin xscf_setssh RW enable RO enable SCF enable When you specify whether to enable or disable the SSH function independently for every function of Standard console Read only console and XSCF shell issue the following command The SSH settings of the function which omitted specification do not change opt FJSVmadm sbin xscf_setssh RW enable SCF disable When you want to see the telnet or the SSHsettings status use the scfstat command The following is an example of command execution opt FJSVmadm sbin scfstat console console LAN inet xx xx xx xx mask yy yy yy yy gateway ZZ Zz 2Z zz hostname name domain dns ww ww ww ww RW port enable SSH RO port disable SCF port enable timeout disable Note When the version of Machine Administration function does not correspond to the SSH settings of XSCF itis displayed as disable in each function which was set to enable SSH in Show Current Configuration of Console Administration on the Machine Administration Menu Note The following is a reference of the xscf_setssh command on the Machine Administration function NAME xscf_setssh enabeles or disables the SSH function of XSCF SYNOPSIS usr sbin FJSVmadm xscf_setssh RW enable disable RO enable disable SCF enable disable DESCRIPTION The xscf_setssh command enables or disables the SSH fucntion of XSCF To use the SSH function it is nessessary to have permitted the use of the telnet port of a pe
113. Specify a password for the XSCF_ user Specify a password of 8 to account 16 characters User account setting menu operation In the beginning select User Account Administration from XSCF Administration of the Machine Administration Menu by its number Examples XSCF Administration 1 Network Configuration 2 User Account Administration 3 Console Administration 4 XSCF Web Administration 5 SNMP Administration 6 Mail Administration q Quit b Back to previous menu t Go to topmenu h Help Select 1 6 q b t h 2 Account setting To add user account choose Add User in User Account Administration Examples 2 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings User Account Administration 1 Show User List 2 Add User 3 Delete User 4 Update Password q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 q b t h 2 Next Add User Users can be registered up to 8 accounts lt user gt lt group gt yyyyy others ZZZZZ others a Add User q Quit b Back to previous menu t Go to topmenu h Help Select a q b t h a Next Add user Some lines omitted Select a q b t h a Return Enter User Name abc1234 Next Select User Group 1 root 2 others q Quit b Back to previous menu t Go to topmenu h Help Choose the group of the user lt username gt 1 2 q b t h 1 Return Do you add a use
114. Status changed XXXXXXXX CODE XXXXXXXX Explanation An RCI IO device is recovered or re mounted Replacement part number A1 FF Action None Error level report level error detection source Notice 0 XSCF aed Message Emergency Power off XXXXXXXX Explanation An RCI IO device was forcibly powered off Replacement part number A1 FF Action Contact the system administrator or a FE Error level report level error detection source Notice 3 XSCF se migoes Message This is a TEST log Explanation A test Notice level is executed in XSCF shell function Replacement part number FE test FF Action None Error level report level error detection source Notice 3 XSCF 4000000 Message FMEM data error PANEL EEPROM cannot be restored Explanation PANEL cannot be restored because FMEM data error Replacement part number 01 SB 00 Action Contact the system administrator or a FE Error level report level error detection source Notice 3 XSCF SpE Message Option data changed Explanation A SSH host key was changed Replacement part number FF FF Action Check the changing of the SSH host key Error level report level error detection source Notice 0 XSCF 4E07200n Message Correct error count over flow Explanation Count of ECC correctable errors detected by the CPU n exceeds the threshold Replacement part number FF FF Action None Error level report level error detection source Notice 0 XSCF
115. T Table B 1 11 Notice level errors 3 Error code Message and explanation FE0000FF Message Unsupported DIMM is mounted Illegal memory SLOT xx 1 Explanation Unsupported SLOT DIMM is mounted Replacement part number 21 SLOT 00 15 model 450 R 450 Q 21 SLOT 00 15 1 Action For models 450 R 450 Q Replace the SLOT Replace the SLOT 1 Contact a FE Error level report level error detection source Notice 0 OBP 1 The parentheses contains a message or a Replacement part number or a Action at HCP version 10 01 or after Table B 1 12 Notice level errors 4 Error code Message and explanation 60000200 Message Part status reset Explanation The failure of parts is recovered Replacement part number M Action None Error level report level error detection source Notice 0 Machine Administration M About part number refer to Table B 1 P for details Alarm Warnig Notice Information The content of the error messages might be changed because of the function improvement B 60 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Table B 1 T POST OBP test phase number Number Phase abbreviation Explanation Number Phase abbreviation Explanation Explanation Number Phase abbreviation 11 RST Rreset phase 1B NVRAMRC NVRAMRC execution phase 27 BOOTOS OS phase 12 BI1 Inialization 1 1C PCI PCI probing phase
116. Up XSCF This chapter explains how to set up XSCF This chapter has the following contents Contents 2 1 XSCE Setup Flow 2 2 Specifying the XSCF Settings 2 2 1 Network Configuration 2 2 2 User Account Administration 2 2 3 Console Administration 2 2 4 XSCF Web Administration 2 2 5 SNMP Administration 2 2 6 Mail Administration 2 2 7 REMCS Environment Setting via XSCF 2 2 8 SSH Administration All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 4 2 4 2 8 2 12 2 16 2 21 2 25 2 31 2 34 2 1 Chapter 2 Setting Up XSCF 2 1 XSCF Setup Flow Each XSCF function needs set up in prior to start using of them Make the following settings Network Configuration required User Account Administration required Console Administration required XSCF Web Administration optional SNMP Administration optional Mail Administration optional REMCS Environment Setting via XSCF optional SSH Administration optional To make the settings use the Machine Administration Menu which runs on Solaris OS 1 Issue the below command and start up the Machine Administration Menu usr sbin FJSVmadm madmin For information about the Machine Administration Menu see the Machine Administration Guide for ESF The setup flow is outlined below For details of how to specify the settings see the sections following this section 2 First open the Machine Administration Menu on th
117. Web Administration of XSCF Administration in Machine Administration Menu In addition to log in XSCF with root level authority For more information about settings see Chapter2 Setting Up XSCF Mailer settings for immediate reporting by mail to users of problems that occur while the remote Panel are being used For details of the settings see Chapter2 Setting Up XSCF and Chapter5 How to Use the XSCF Web Function Accessing the remote Panel 1 On a console connected to the SCF LAN port open a browser page and enter the specified host name to make access to XSCF 2 The XSCF top page is displayed Click login button on the top page then log in to XSCF using the user account 4 Select the remote Panel from the displayed index ad Operating the switches Figure 4 1 shows the switch buttons and the mode switch on the remote Panel The switches are listed below Power switch Reset switch Request switch Mode switch slide switch Power switch Click the power switch button on the front remote panel to turn server power on and off To be able to performe this switch operation set Enable with read write mode and log in XSCF with root level authority When you turn on the server power the following events occur 1 The POWER LED on the front panel light immediately However there is a possibility of not lighting at once according to the setting 4 4 All Rights Reserved Copyright C FUJITSU L
118. Web Function 5 3 Logging In to or Out from XSCF 5 4 XSCF Web Function Pages All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 5 2 5 5 5 8 5 1 Chapter 5 How to Use the XSCF Web Function 5 1 5 2 Overview of the XSCF Web Function The XSCF Web function which connects to a server on the Web using the http and SSL TLS protocols enables the display of the server status the control of server connected devices and the viewing of server configuration with a Web browser Registered users can connect to XSCF Web function pages using a Web browser on a client terminal and then log in to XSCF using the XSCF user account XSCF account hereafter After login the XSCF page index from which the desired page can be selected is displayed For information about registering XSCF users see Chapter2 Setting Up XSCF Table 5 1 describes the XSCF Web function pages Table 5 1 XSCF Web function pages Page Description To It s a top page of XSCF Allows users to call the authentication P page Also allows users to specify XSCF of other server Authentication Allows users to log in to XSCF using the XSCF account Allows users to select a desired page when login has been Index successful Displays the front and back remote panel of the server If settings for XSCF Web function permit operations on the remote Remote con panel the switches on the remote panel with the exception of
119. XSCF B 50 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6100000n Message Mail illegal POP server n specified Explanation An illegal POP server name was specified Replacement part number FF FF Action Recheck the POP server name Error level report level error detection source Notice 0 XSCF 6100100n Message Mail Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100110n Message Mail Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100120n Message Mail Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100130n Message Mail Name Resolution of POP server n f
120. XX 33 TTY B XX 34 HPC 0 2 XX 35 37 SCSI 0 1 XX 40 41 LAN 0 1 XX 42 43 ATAPI O XX 44 USBC XX 45 Replacement part number 01 SB 00 or IO Action Contact a FE Error level report level error detection source Warning 3 POST 153A000X X 8 9 b Message U2P Timer Counter error U2P Timer X Explanation A U2P timer error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 153z00XX z 0 1 9 Message U2P Timer Counter error U2P Timer n Explanation A U2P timer error was detected n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 154z00XX 2 0 1 3 Message U2P Functional error U2P n Explanation A U2P functional error was detected n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 39 1560002n Message U2P PCI Slot error PCl 0n Explanation Abnormal reponse is received from a PCI slot Replacement part number 92 PCI 00 08 Action Contact a FE Error level report level error detection source Warning 3 POST 16000039 Message TOD test erro
121. a SECC CCS CESS AAO Check proccessing Start SESS SOOO SOOO E E E EE EEE E EE EE E E AAA Warning Source 0001 You should check the representation of Enterprise OID in your target SystemWalker system kkk k Check processing has ended Processed records gt 329 Processed definitions 7 EELEE EEEk c All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 7 5 Introduce Extended MIB of XSCF to SNMP Manager Note The MIB file can be refferred to from the following path in the HCP CD too PWPO MIB Step 7 Click as follows in the application System Monitor of SystemWalker Policy menu Distribute policy Policy Distribution dialog box is displayed Step 8 Select Apply immediately Restart distribution destination service in Policy Distribution dialog box and click OK Policy Distributing Status dialog is displayed Step 9 Policy Distributing Status dialog ends automatically when the distribution of the policy ends Next a setup which calls XSCF WEB function from SystemWalker is performed Step 10 Click in the following order on System Monitor windows of SystemWalker Select Tools menu and go Add Operation Menu Add Operation Menu dialog box is displayed Step 11 Select Single System and click Add button Single System Add dialog box is displayed Step 12 Set the following items and click OK button Menu Item S
122. a FE Error level report level error detection source Warning 3 POST 921032XX Message data_access_error SLOT yy yy Explanation A memory error occurred yy yy XX 00 01 80 02 03 81 14 15 87 Replacement part number 22 SLOT 00 15 Action Contact a FE Error level report level error detection source Warning 3 POST 921063XX Message ECC_error SLOT yy yy Explanation A memory error occurred yy yy XX 00 01 80 02 03 81 14 15 87 Replacement part number 22 SLOT 00 15 Action Contact a FE Error level report level error detection source Warning 3 POST xxxC000n p Message CPU Degrade error CPU n Explanation Part of internal sections in CPU is degraded Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST p xx Test phase number XX yy Component number zzz Component name ppp Phase abbreviation Please refer to Table B 1 T and Table B 1 C for details Alarm Warnig Notice Table B 1 7 Warning level errors 3 Error code Message and explanation A000000n Message CPU was degraded CPU n Explanation A CPU of the dergadation by OS occurred Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 0 OBP A010006n Message DIMM was degraded SLOT n Explanation A DIMM slot of the dergadation by OS oc
123. a FE Error level report level error detection source Warning 3 XSCF C310000n Message CPU n FRU access error Explanation An FRU access error on CPU n was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C4yyyy1n x Message FAN xx alarm XXXXXXXX CODE XXXXXXXX Explanation A fan error was detected Replacement part number A1 FF Action Replace the fan of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C4yyyy2n x Message Power Unit alarm XXXXXXXX CODE XXXXXXXX Explanation A power supply error was detected Replacement part number A1 FF Action Replace the power supply unit of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C4yyyy3n x Message Memory backup battery alarm XXXXXXXX XX Explanation A memory battery error was detected Replacement part number A1 FF Action Replace the battery of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C4yyyy4n x Message Extend power alarm XXXXXXXX CODE XXXXXXXX Explanation An extended power interface error report
124. a setting of POP authentication server is added And description of host name specifying is added Figures 8 1 is changed In Figures 8 4 8 7 Mail contents are changed In Contents of Parts Fault Notification a fault part PCI RISER is added System Damage Level is added in contents of mail In Table 8 1 Network access types and port numbers SSH ports is added TELNET 23 port number is deleted Chapter 9 XSCF REMCS Agent Function is added newly All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 10 XSCF Firmware Upgrade and Dump This is moved from Chapter 9 The method of firmware update in Registration from applying of the ESF patch are added Appendix B XSCF Log Information XSCF Error Log List are corrected Error codes 501030FF 501031FF 501040FF 501050FF 6100000n 620100FF C20302FF and C3170000 are added Error codes 4201010n 4201810n 42040100 42048100 8201020n 8201050n 830101FF 830104FF 83020100 830B010n 830B0D0n 830B0FOn 830B110n 830E000n 8313010n 8314010n C201020n C201030n C2010400 C3010000 3020000 C3030000 C3050000 C30B020n C30BOE0n C30B100n C30B120n C30E010n C30F0000 C313000n C314000n C3160400 CE03050n CE04030n CE201000 and C30F0000 are corrected Error code number is corrected as below 60000100 gt 60000200 XSCF Power Log List are corrected When the input power sourc
125. acement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 0BP B 20 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 263000XX p Message BOOTB SCSI I O error Explanation A disk boot error was detected BOOTB Boot block phase Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 OBP 264000XX Message BOOTB PCI S ERR XX 50 55 Explanation A PCI address parity error occurred BOOTB Boot block phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 265000XX Message BOOT B network error LAN n XX 42 43 Explanation A network boot error occurred BOOTB Boot block phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 266000XX Message BOOTB network error LAN n XX 42 43 Explanation A network boot error occurred BOOTB Boot block phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 270000FF Message BOOTOS Boot OS failed Explanation Initialization of OS on the OBP environment was abnormally terminated BOOTOS OS phase Replacement part number FF FF Action
126. ailed Explanation Name Resolution of POP server failed POP server n was not found Replacement part number FF FF Action Recheck the POP server Error level report level error detection source Notice 0 XSCF 6100140n Message Mail communication to name server timeout Explanation Name Resolution of POP server failed The timeout occurred by the Name server Replacement part number FF FF Action Recheck the POP server or the Name server Error level report level error detection source Notice 0 XSCF 6100150n Message Mail Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100160n Message Mail Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100170n Message Mail Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF
127. ailed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Recheck the POP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100240n Message Mail communication to POP server n timeout Explanation The timeout occurred by the POP server n Replacement part number FF FF Action Recheck the POP server Error level report level error detection source Notice 0 XSCF 6100250n Message Mail communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Recheck the POP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100310n Message Mail communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100320n Message Mail communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact
128. apter 8 XSCF Mail Function 8 12 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter9 XSCF REMCS Agent Function This chapter explains the REMCS agent function via XSCF This chapter has the following contents Contents 9 1 Summary of XSCF REMCS Agent Function 9 2 Part of XSCF 9 3 Types of REMCS Center Connection 9 4 How to Set up the XSCF REMCS Agent Function All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 9 2 9 4 9 5 9 8 9 1 Chapter 9 XSCF REMCS Agent Function 9 1 Summary of XSCF REMCS Agent Function REMCS REMote Customer Support system Agent is software which spares customer s effort and time in order to maintain customer s system REMCS Agent works with help of the REMCS center system A customer s machines are monitored by REMCS Agent instead of the customer and REMCS Agent supports the customer s operations by communicating with the support center via networks The following is summary of REMCS agent fucntion For more information about REMCS Agent function see the REMCS Agent Operator s Guide for the ESF Registration Registration function sends customers machine information such as software configuration hardware configuration and registers it to the center REMCS Agent automatically collects the machine information and sends it to the center If the system configuration of a machine is changed the change is automatically detected Information on the chang
129. arams 1 DisplayString R Host name OS scfTrapTime scflrapParams 2 TimeTicks R scfServerUpTime value of trap occurred 1 scfHWErrComment scfTfrapParams 3 DisplayString R Error information 3 scfHWConfAddr scffrapParams 4 DisplayString R Faulty parts 1 scfServerUpTime is the lapsed time since SNMP AGENT starting The unit is 10ms 2 Because SNMP uses the UDP protocol trap may not reach a manager when a network path is an abnormal condition In addition to the surveillance by TRAP we recommend you to supervise the state of scfHWErrLevel periodically scfHWErrLevel shows the worst part state in the parts with trap sending reference 7 3 Abot Traps It is indicated as the following three kinds of status scfHWErrLevel No error or WARNING or ALARM 3 The following shows the format of the error information Error generation time Error code Error message The explanation of the Error code and Error message see Appendix B XSCF Log Information All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 scfMonitor group Table C 12 scfMonitor group MIB OBJECT ID SYNTAX R CONTENT Ww scfTemperatureTable scfMonitor 1 Aggregate NA MIB table of temperature scfTemperatureEntry scfTemperatureTable 1 Aggregate NA scffemperaturePartsName_ scffemperatureEntry 1 INTEGER R Parts name 1 scfTemperaturePartsNumber scffemperatureEntry 2 INTEGER R Parts num
130. arm 4201010n Warning 4201010n Notice 4201030n 4201040n 4201810n 4201840n 42040100 42040300 4204030n 420403FF 4204040n 42048100 43000000 and up 430102FF 430103FF 430E060n 431501FF 431601FF 431602FF 431605FF 431606FF 431607FF 44000000 and up 44yyyyA0 44yyyyE0 46000000 and up 46110000 4D000000 and up 4D000700 4D0008FF 4E000000 and up 4E07200n 4E200800 4E20F00n 4E20F50n 4E20F600 50000000 and up 500001FF 500002FF 500003FF 500004FF 500110FF 500111FF 500112FF 500113FF 500114FF 500115FF 500120FF 500121FF 500130FF 500131FF 500132FF 500133FF 500134FF 500135FF 500136FF 500137FF 500140FF 500141FF 500142FF 500143FF 500144FF 500145FF 500146FF 500147FF 500150FF 500151FF 500152FF 500153FF 500154FF 500165FF 500170FF 50100000 and up 501001FF 501002FF 501003FF 501004FF 501010FF 501011FF 501012FF 501013FF 501020FF 501030FF 501031FF 501040FF 501041FF 501042FF 501048FF 501049FF 501050FF 5080000n 61000000 andup 6100000n 6100100n 6100110n 6100120n 6100130n 6101000n 61010100 6101100n 6101110n 6101120n 6101130n 6101140n 6101150n 6101160n 6101170n 6101320n 6101330n 6101340n All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 61100000 andup 6110000n 6110100n 6110110n 6110120n 6110130n 6111000n 61110100 6111100n 6111110n 6111120n 6111130n 6111140n 6111150n 6111160n 6111170n 6111320n 6111330n 6111340n 61200000 andup 612000FF 612002FF
131. arnig 3 Warnig 4 Notice 1 Notice 2 Notice 3 Notice 4 Table B 1 9 Notice level errors 1 Error code Message and explanation 408055FF Message SCF FMEM version changed Explanation SCF FMEM was upgraded to a new version Replacement part number FF FF Action Check the version Error level report level error detection source Notice 3 XSCF stagtoed Message TTY trace saved CAUSE PANIC Explanation A tty trace was executed because a panic occurred Replacement part number FF FF Action None Error level report level error detection source Notice 0 XSCF ion Message POST OBP trace requested Explanation POST OBP requested a trace Replacement part number FF FF Action None Error level report level error detection source Notice 0 XSCF ene Message This is a TEST log Explanation A test Notice level is executed in Machine Administration function Replacement part number FE test FF Action None Error level report level error detection source Notice 3 XSCF 4201010n Message PSU n ACFAIL When the input power source is the AC Type PSU n input failure When the input power source is the DC Type Explanation Voltage reduction of input power source was detected Replacement part number 41 PSU 0 2 Action Check the installation environment Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and lO back panel Or Replace t
132. art number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0805300 Message XSCF boot header error Explanation A boot header identifier error was detected in SCF FMEM Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0806000 Message SCF CPU PIT timeout error Explanation A PIT interrupt did not occur in the SCF CPU Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C0806100 Message SCF CPU WDT timeout error Explanation A WDT interrupt did not occur in the SCF CPU Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0807000 Message SCF SDRAM ECC CE test error Explanation ECC did not detect a correctable error in SCF SDRAM Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0807100 Message SCF SDRAM ECC CE test compare error Explanation ECC corrected a correctable erro
133. art of UPC PC Use PC I F when the power supply of the server is turned on from the input output device power supply control box etc Use UPC UPS I F to request shut down of the system promptly from UPS to defend the server from voltage reduction or black out of commercial power source Note Power supply control box may not be available in your area due to voltage difference Next 3 4 Connecting of RCI All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 4 Connecting of RCI 3 4 Connecting of RCI Use the RCI interface to control the power supply of the servers and the I O devices composed with the cluster This section explains the connection method For the initialization when RCI is connected with XSCF refer to How to configuring RCI 3 4 3 3 4 1 Basic Configuration The case where two or more IO devices are connected with one server is indicated as follows File unit FDE File unit FDE fe ea aH RCI cable RCI terminator T divergence connector Figure 3 7 connection chart of basic configuration Connect the RCI cable to each device with T branch connector Connect the RCI terminator with T divergence connector which becomes both ends of the RCI connection All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server 3 4 2 Cluster Configuration The case where two or more I O devices are connected with two or more servers is indi
134. at the standard console terminal connected via the serial port tty a displays the console PUN Next 3 2 Types of XSCF Connection All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server 3 2 Types of XSCF Connection This section describes the types of XSCF connection Connecting XSCF to the LAN port recommended XSCF is connected to the SCF LAN port The Ethernet connection used for XSCF connection is shown in Figure 3 1 When XSCF is connected via the LAN the XSCF functions listed below can be fully used For the summary of these functions see Chapter1 Overview of XSCF XSCF shell function XSCF Web function SNMP agent function Mail report function 1 Intranet connection a telnet connection i or n al connect ion Sei corte Ga i or 3 S connect ion a http connect ion a http connect ion Terminal Terminal Router m Hail not if ication nt ranet S rer SCF LAN port Serial port Figure 3 4 Intranet connection When you use the XSCF Shell you can have high security by using SSH not telnet The XSCF Web function uses the Secure Socket Layer SSL to provide authentication security All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 2 Types of XSCF Connection 2 Connection via an external network a telnet connection or SSH connect ion or m http connect ion Terminal i nternet Terminal m t
135. ation Information Command SCF gt lan config 0S LAN Information Nest Naje aS Lexamp e com MAC Address lt Primary LAN gt 00 EE 00 CC 88 22 Clete 00 EE 00 CC 88 22 lt Secondary LAN gt 00 EE 00 55 88 22 SCF LAN Information Riepart Sseeesssssesee Enable REPOT sae Enable a ee Enable Host Name example1 com IP Address __________ 11 22 333 44 Subnet Mask Address 255 255 255 0 Gateway IP Address 11 22 333 4 MAC Address lt SCF LAN gt 00 EE 00 55 00 22 SCF gt 6 6 Other XSCF Commands 6 27 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 6 6 Other XSCF Commands Use the following XSCF shell commands to terminate the XSCF shell view the version information and perform similar functions send break exit help show shell command set shell command logtest version send break The send break command is used to send a break signal to the server The server OS console prompt changes to ok The required authority for this command is root level The following is an example of command execution SCF gt send break SCF gt Caution You cannot enter the OpenBoot environment when the mode switch is set to LOCK exit The exit command is used to terminate the XSCF shell The following is an
136. ation clustering solution that provides high availability and scalability which is independent of the operating system and hardware platform In the software product there are PRIMECLUSTER and SafeCLUSTER CPUDDC The DDC for the CPU core CPUDDC is mounted on the CPU module DDC An abbreviation of DC DC converter ADDC converts one direct current voltage to another direct current voltage DDC A ADDC mounted on a system board that supplies 1 8 V All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 DDC B ADDC mounted on a system board that supplies 2 5 V DDC C ADDC mounted on a system board that supplies 1 25 V DIMM An abbreviation of dual in line memory module DIMMs are memory modules that are mounted on the motherboard ECC An abbreviation of Error Check and Correction ECC is a mechanism for monitoring memory operation When ECC detects a one bit memory error it automatically corrects the error and operation continues ECC also detects two bit memory errors EEPROM An abbreviation of electrically erasable programmable read only memory EEPROM is ROM whose contents can be electrically reprogrammed EPROM An abbreviation of erasable and programmable read only memory EPROM is electrically erasable and programmable read only memory Erase The operation of erasing memory or a disk External power controller A controller that provides among other functions a conversion function between the p
137. below 130000FF gt 1300000X 150000FF gt 1500000X 160000FF gt 1600000X 170000FF gt 1700000X 180000FF gt 1800000X 181000FF gt 1810003D 182000FF gt 1820003D 2E2000FF gt 2E200000 Appendix D Troubleshooting In Troubleshooting XSCF and FAQ descriptions of FAQ are added Summary of Changes in Sixth Edition The current sixth edition of this manual differs from previous edition principally by containing vi All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 the addition of descriptions about the error code The sixth edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition Chapter 1 Overview of XSCF In Types of Connection to XSCF a description of tty a console path is added Chapter 6 How to Use the XSCF Command Shell In nodeled command note is added Chapter 7 XSCF SNMP Agent function In About Traps Note about the target parts for trap is added Appendix A Warning And Information Messages Control execution messages during the monitoring for foreseeable faults is added Appendix B XSCF Log Information XSCF Error Log List are corrected Error codes 07060030 07140031 0801000X 0A00000X 0A1z000X OCOO0000X 10100030 150z000n 153A000X 1A00000n 21000045 250000FF 2 33000039 330000FF 330000FF_ 2 4D0008FF 4E07200n 5080000n 9080000n DO80000n and xx
138. ber 1 scfTemperatureSubIndex scffemperatureEntry 3 INTEGER R senser number 2 scfTemperatureStatus scffemperatureEntry 4 INTEGER R Status of value 3 value unit 0 1 degrees scfTemperatureValue scffemperatureEntry 5 INTEGER R C scfVoltageTable scfMonitor 2 Aggregate NA MIB table of voltage scfVoltageEntry scfVoltageTable 1 Aggregate NA scfVoltagePartsName scfVoltageEntry 1 INTEGER R Parts name 1 scfVoltagePartsNumber scfVoltageEntry 2 INTEGER R Parts number 1 scfVoltageSubIndex scfVoltageEntry 3 INTEGER R senser number 2 scfVoltageStatus scfVoltageEntry 4 INTEGER R status of value 3 scfVoltageValue scfVoltageEntry 5 INTEGER R_ value unit 0 01 V MIB table of FAN rotation scfRotationTable scfMonitor 3 Aggregate NA rate scfRotationEntry scfRotationTable 1 Aggregate NA scfRotationPartsName scfRotationEntry 1 INTEGER R Parts name 1 scfRotationPartsNumber scfRotationEntry 2 INTEGER R Parts number 1 scfRotationSubIndex scfRotationEntry 3 INTEGER R_ senser number 2 scfRotationStatus scfRotationEntry 4 INTEGER R status of value 3 scfRotationValue scfRotationEntry 5 INTEGER R__ Value unit 1 rpm 1 see table B 1 P Part number table 2 Identification number in installing of two or more sensors on same parts 3 invalid 1 Next C 4 TRAP C 8 valid 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C 4 TRAP The following information i
139. ber 80 is deleted In Connecting Terminals to XSCF a description of the processing for switching the standard console port OS console to the serial port tty a forcibly is added In Method of constructing RCI the command rci config init is corrected to rci configio init Chapter 4 How to Use the Remote Panel In Table 4 1 Remote panel components and How to Use the Remote Panel descriptions of enabling the switch operation are added Chapter 5 How to Use the XSCF Web Function In Table 5 1 XSCF Web function pages description of Note is added In Table 5 2 Supported browsers version of browsers is changed And Mozilla is deleted Netscape Communicator TM is added Chapter 6 How to Use the XSCF Command Shell The commands of logtest show mail report show remcs show connections hangup are added In Login to XSCF User Account and show access logs command descriptions aboout SSH are added In help command the view of command detail information is added The command authority level in the show shell command command is corrected Chapter 7 XSCF SNMP Agent function In Introduce Extended MIB of XSCF to SNMP Manager Descriptions of MIB file in HCP CD are added Chapter 8 XSCF Mail Function In Overview of XSCF Mail Function descriptions of POP authentication are added In Setting up the XSCF Mail Function
140. ble see the User s Manual for the server The following is the procedure for connecting to a terminal using telnet via the LAN port 1 Make sure that the LAN cable from the HUB is connected to the SCF LAN port connector on the rear of the server Comfirm the secure connection to the PC or workstation also 2 On the PC or workstation to be used use one of the following procedures 3 4 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 1 Connecting Terminals to XSCF Connecting to a terminal dedicated to the XSCF shell host name 10 24 144 204 v port 8010 terminal type vt100 connect cancel Figure 3 2 Example of activating the terminal emulator 1 To establish a telnet connection activate the terminal emulator and specify the IP address of XSCF and port number 8010 2 Enter the ID and password to start the XSCF shell 3 Make sure that the XSCF shell prompt SCF gt is displayed 4 The XSCF shell can now be used Note You can connect to the XSCF shell even when the power of the system is off Connecting to the Standard console OS console 1 Ifthe server is off turn it on to start the OS 2 To establish a telnet connection activate the telnet cliant and specify the IP address of XSCF and port number 23 3 Enter the ID and password 4 Make sure that the terminal becomes the OS console for which input and output are enabled Caution When you use the Standard co
141. by CPU Source Ob ACK timeout Detailed code x00000000 Explanation Power off was executed due to timeout of communication ACK timeout Source 0C UPS Detailed code x00000000 Explanation Power off was executed because the battery voltage was low It was caused by a power outage Source 0C UPS Detailed code x01000000 Explanation Power off was executed because of the battery error Source 11 LAN Detailed code x00000000 Explanation Power off was executed via LAN Source 12 TTY Detailed code x00000000 Explanation Power off was executed via TTY Source 14 Power supply monitoring Detailed code x01000000 Explanation Power off was executed because of PSU error Source 14 Power supply monitoring Detailed code x02000000 Explanation Power off was executed because of DDC A error Source 14 Power supply monitoring Detailed code x03000000 Explanation Power off was executed because of DDC B error Source 14 Power supply monitoring Detailed code x04000000 Explanation Power off was executed because of CPUDDC error Source 14 Power supply monitoring Detailed code x05000000 Explanation Power off was executed because of DDC C error Source 16 Temperature monitoring Detailed code x01000000 Explanation Power off was executed because of CPU temperature error Source 17 RCI Host Detailed code xXX000000 Explanation Power off was executed from RCI HOST XX indicates
142. cAddress information Displays the model name serial number name of model type system system clock frequency SB type information and system status includes three bytes of additional information cpun n 0 1 3 Displays the serial number part number version and CPU frequency for each cpu When n is omitted the information for all cpu is displayed Displays the serial number part number version system clock 7 frequency and SB type information of the SysBoard panel Displays the serial number part number and version of the operator panel pcibd Displays the serial number part number and version of the PCI board pcin n 00 01 08 Displays the information for each PCI slot nis a two digit number scsibpn n 0 1 Displays the serial number part number and version of each SCSI board diskn n 0 1 5 Displays the vendor product name version and serial number of each disk psun n 0 1 2 Displays the serial number part number and version of each PSU slotn n 0 1 15 Displays the serial number part number version and capacity of each slot DIMM fann n 0 1 7 Displays the serial number part number and version of each fan lan config The lan config command is used to view the current configuration information for the SCF LAN 6 26 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Next 6 5 XSCF Server Configur
143. cated as follows File unit FDE File unit FDE T divergence connector RCI cable Figure 3 8 Connected chart of cluster configuration RCI terminator Connect the server with both ends of the RCI connection The case where two or more servers share disk file unit File disk Enclosure FDE by the SCSI connection By connecting the servers and FDEs with RCI FDEs are turned on if the server which is turned on exists FDEs are turned off when all servers are turned off All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 4 Connecting of RCI 3 4 3 How to Configure RCI Only our trained field engineer allowed to do following RCI related maintenance The following operations are necessary to use RCI Operate it at the ok prompt of OBP 1 Check the present RCI configuration and the address of the server 0 ok rci config HOST address 000f7f00 mode 20a0 status 00000000 LIST address status device class sub class HOST address address of the server OOOf7f00 is the initial value of address HOST mode mode of power supply for remote control 1 status state of device identified by address displayed in the same row 2 2 Operate the RCI configuration 0 ok rci config 1 1 Setting server ID 1 0 ok rci configio init Normal End rci config n n nis the host number the integer number from 1 to 15 reci configio init Start the configuration process
144. ce Alarm 3 XSCF B 14 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 CE201000 Message UPA O fatal error O 0 xxxxxxxx Explanation A fatal error occurred Replacement part number 01 SB 00 Action For models 250 R4 250 R 250 P 450 R Replace the SB For model 450 Q Replace the PCI board Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE201200 Message UPA O fatal error O 2 xxxxxxxx Explanation A fatal error occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CEAR Message UPA O fatal error IO 3 xXXXXXXX Explanation A fatal error occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE20150n Message Interconnect data error xxxxxxxx Explanation A fatal error occurred Replacement part number 11 CPU 0 3 or 01 SB 00 Action For the Replacement part is CPU Replace the CPU Or Replace the SB For the Replacement part is SB Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE209400 Message Fatal error SC Explanation Logging errors when a fatal error occurs Repla
145. ce Contact the system administrator ora FE Error level report level error detection source Warning 3 XSCF C4yyyy9n Message Mount alarm XXXXXXXX CODE XXXXXXXX x Explanation A mount error was detected Replacement part number A1 FF Action Check the installation status of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C7000100 Message SCF LAN memory access error Explanation A memory access error was detected Replacement part number 01 SB 00 Action Check the LAN environment Then replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C7000200 Message SCF LAN loop back connection error Explanation A data compare error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C7000300 Message SCF LAN MAC duplicate Explanation A MAC address duplication error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C7000400 Message SCF LAN framing error Explanation A framing error was detected Replacement part number 01 SB 00 Action Check the LAN environment replace the SB Contact the system administrator or a FE Er
146. cement part number FF FF Action Recheck the POP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111000n Message Mail illegal SMTP server n specified Explanation An illegal SMTP server name was specified Replacement part number FF FF Action Recheck the SMTP server name Error level report level error detection source Notice 0 XSCF 61110100 Message REMCS no SMTP server specified Explanation SMTP server has not been specified Replacement part number FF FF Action Specify SMTP server Error level report level error detection source Notice 0 XSCF B 56 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6111100n Message REMCS Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111110n Message REMCS Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report
147. cement part number FF FF Action Please check the errors occurred before or after Then perform it as follow Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE209500 Message Fatal error XB Explanation Logging errors when a fatal error occurs Replacement part number FF FF Action Please check the errors occurred before or after Then perform it as follow Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE209600 Message Fatal error CPU n mm Explanation Logging errors when a fatal error occurs mm is detail code Replacement part number FF FF Action Please check the errors occurred before or after Then perform it as follow Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE209700 Message RC data error yy xxxxxxxx Explanation RC data errors caused a fatal error Replacement part number 01 SB 00 Action Replace the SB However if the error occurred after a failure to upgrade firmware retry the upgrade If the upgrade still fails replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE209800 Message Hardware too many errors xxxxxxxx Explanation Analysis is not possible because there are too many
148. cement part number FF FF Action None Error level report level error detection source Notice 0 XSCF 500003FF Message SNMP Agent couldn t start by bad configuration Explanation Inadequate settings were detected when the SNMP agent function started Replacement part number FF FF Action Recheck the settings Error level report level error detection source Notice 0 XSCF MORATE Message SNMP Agent failed to send trap Explanation The SNMP agent function failed to issue a trap Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF ae Message SNMP Agent stopped by firmware 500170FF Explanation The SNMP agent function stopped for a reason related to firmware Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 501001FF Message Illegal XSCF host name specified Explanation An illegal host name of XSCF was specified Replacement part number FF FF Action Recheck the specified host name of XSCF Error level report level error detection source Notice 0 XSCF 501002FF ER Message Communication to SMTP server timeout Explanation A timeout occurred during communication with the SMTP server Replacement part number FF FF Action Recheck the server setting Error level report level error
149. center via XSCF Wait for a while After the REMCS Center makes a confirmation mail is returned to the administrator Press any key Information The layout and the content of the menu show a sample It might be changed because of the function improvement 2 33 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF 2 2 8 SSH Administration Specify the SSH function of XSCF This is optional The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration REMCS Administration SSH Administration Table 2 8 XSCF SSH Administration Item Description Remarks Host Key Download the Host key to XSCF The temporary host key is setting set by default SSH setting Specify whether to enable or disable the SSH The SSH function is function disabled by default Supporting SSH protocol The XSCF supports both SSH1 SSH Protocol Version 1 and SSH2 SSH Protocol Version 2 The following table lists the setting value of SSH in XSCF Table 2 9 XSCF SSH Setting value Item Description Remarks Server Key 3600 seconds Used by SSH1 Regeneration Interval Server Key Bits 768 bits Used by SSH1 Encryption 3des cbc blowfish cbc Algorithms MAC Algorithms hmac md5 hmac sha1 Used by SSH2 Data Enabled Compression
150. ct a mailing test Examples Send Test Mail XSCF will send test mail with following configuration To user example com From admin example com SMTP Server1 smtp server POP Server1 smtp server SMTP Server2 q Quit b Back to previous menu t Go to topmenu h Help Do you execute y n q b t h y Return Test mail was sent Hit return key Setting on the command line The Mail Administration can also be set by using the scfmail 1M command of the Machine Administration function Use the scfstat 1M command to display the configuration information When you set up the Mail Administration on the command line please perform the scfreset 1M command to reflect the setting For details of these three commands of the Machine Administration function see the command reference in the Machine Administration Guide for the ESF The commands are at ESF2 5 1 or later 2 28 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Information The layout and the content of the menu show a sample It might be changed because of the function improvement 2 29 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Display current configuration To check the current configuration in each setting of XSCF Administration choose Show Current Configuration of each menu 2 30 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005
151. ct the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E208800 Message Hardware too many errors Explanation Analysis is not possible because there are too many error factors Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E208900 Message Hardware no error region xxxxxxxx Explanation Analysis is not possible because there are no error factors Replacement part number FF FF Action Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E20F30n Message Uncorrec error Internal xxxxxxxx Explanation A hardware error detected Replacement part number 11 CPU 0 3 Action Replace the CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E20F40n Message Uncorrec error Outside xxxxxxxx Explanation A hardware error detected Replacement part number 01 SB 00 or 11 CPU 0 3 Action Replace the SB or SLOT memory or CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E20F700 Message Uncorrec error Marked xxxxxxxx Explanation A hardware error detected Replacement part number 01 SB 00 Action Do the action of the error generated b
152. ction Contact a FE Error level report level error detection source Warning 3 POST 1120006n Message Probing memory error SLOT n Explanation A SPD checksum error was detected Replacement part number 21 SLOT 00 15 Action Contact a FE Error level report level error detection source Warning 3 POST 1121006n Message Probing memory error SLOT n Explanation A SPD data error was detected Replacement part number 21 SLOT 00 15 Action Contact a FE Error level report level error detection source Warning 3 POST 112300F0 Message Probing memory error No avail memory Explanation There is no memory which can be used Replacement part number FF FF Action Contact a FE Error level report level error detection source Warning 3 POST 120z00XX z 0 1 2 Message Memory Address Line error SLOT yy yy Explanation A memory error occurred vy yy XX 00 01 80 02 03 81 14 15 87 Replacement part number 22 SLOT 00 15 Action Contact a FE Error level report level error detection source Warning 3 POST 140z000n z 0 1 4 Message Softint register error CPU n Explanation A CPU softint register error was detected Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Wanrning 3 POST B 38 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 141z000n z 0 1 3 Message
153. ction source Notice 0 XSCF 6110150n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110160n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Recheck the POP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110170n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110180n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110190n Message REMCS name server invalid Explanation Name R
154. curred Replacement part number 21 SLOT 00 15 Action Contact a FE Error level report level error detection source Warning 0 0BP A02000XX Message U2P was degraded U2P n Explanation A U2P of the dergadation by OS occurred n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP B 42 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 A030001n Message U2P Timer n was degraded Explanation A U2P timer of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 0BP A040002n Message PCI was degraded PCl 0n Explanation A PCI of the dergadation by OS occurred Replacement part number 92 PCI 00 08 Action Contact a FE Error level report level error detection source Warning 0 OBP A050004n Message SCSI was degraded SCSl n Explanation A SCSI of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP A0600044 Message ATAPI was degraded Explanation An ATAPI of the dergadation by OS occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 0 OBP A07000XX XX 42 43 Message
155. d is at ESF2 5 1 or later System control bus The bus used for communication between system components and for monitoring of the environment TTY An abbreviation of teletypewriter Generally a unit for displaying input and output characters on the console or its virtual feature simulated by hardware or software TTY A The serial port usually used for the standard console and XSCF shell TTY B The serial port usually used for a serially connected unit such as the external clock device U2 Cache The secondary cache of a CPU U2P An abbreviation of UPA to PCI The LSI circuitry between the UPA bus and the PCI bus UART An abbreviation of universal asynchronous receiver transmitter A UART is a telecommunication circuit used for the serial port of a PC or similar device It converts the parallel signal sent from the PC to a serial signal and the serial signal sent from a peripheral device to a parallel signal UE An abbreviation of uncorrectable error UPA An abbreviation of Ultra Port Architecture UPA is the protocol specifications for connecting W 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 W 6 the CPU IO memory and other components It is used as the interface between the CPU and SC U2P and the SC and the SC and XB UPC An abbreviation of uninterruptible power control UPC is an interface port with an uninterruptible power supply unit UPS An abbreviation of uninterruptible power
156. default Q3 Can I connect the SCF LAN to the Basic LAN Yes you can There are three LAN ports called Basic LAN Extended LAN or SCF LAN in the server You can connect the SCF LAN with user LAN Basic LAN and Extended LAN For more information about the connection of the SCF LAN see Chapter3 Connecting XSCF or D 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Server Q4 During power on and startup OS if the OS hangs up can power off the server by using XSCF function When the OS hangs up you should not power off the server first but do the following 1 First please push the request switch on the remote panel of the XSCF Web function or push the request switch on the operation panel of the server or issue the request command by using the XSCF Shell then the OS dump is executed 2 After processing No 1 if the OS dump failed please send a Break or push the reset switch on the remote panel of the XSCF Web function or push the reset switch on the operation panel of the server or issue the xir command by using the XSCF Shell then the server returns the ok prompt And type the sync command 3 After processing No 2 if reset operating or the sync command failed please issue the por command by using the XSCF Shell or forcibly power off in the following methods There are the following three methods to power off the server forcibly Method 1 Push the power switch button for 10 s
157. dentify the server For the XSCF shell commands that are used to check the LEDs see Chapter6 How to Use the XSCF Command Shell SCF Ready LED The SCF Ready LED on the remote panel is green when it is on When power has been turned on 4 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 4 How to Use the Remote Panel 4 8 the SCF Ready LED blinks throughout the system power on sequence The blinking indicates that XSCF is being initialized When the system power on sequence is completed the SCF Ready LED lights When power is turned off the SCF Ready LED remains on until the power off sequence has been completed Like the POWER LED and the ONLINE LED the SCF Ready LED is green while system is working You can determine the operating status of the server by checking the SCF Ready LED together with the other LEDs For information about the server status and LED indications see the User s Manual for the server Next 4 4 Differences from the Operating Panel All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 4 4 4 Differences from the Operating Pa Differences from the Operating Panel This section describes the differences in indications and operations between the remote Panel and the operating Panel Table 4 2 lists these difference by component Table 4 2 Remote panel and operating panel differences nel gh Indication operation Remote Pa
158. detection source Notice 0 XSCF B 48 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 501003FF ea Message Communication failure to SMTP server occurred Explanation A communication error with the SMTP server occurred Replacement part number FF FF Action Recheck the server setting Error level report level error detection source Notice 0 XSCF 501004FF f ae Message Mail report function is not enabled Explanation The mail report function has not been enabled Replacement part number FF FF Action Recheck the mail report function settings Error level report level error detection source Notice 0 XSCF 501010FF p P Message Mail access mode is not enabled Explanation Mail access mode has not been enabled Replacement part number FF FF Action Recheck the mail access mode settings Error level report level error detection source Notice 0 XSCF 501011FF Message Illegal SMTP server address specified Explanation An illegal SMTP server address was specified Replacement part number FF FF Action Recheck the mail access mode settings Error level report level error detection source Notice 0 XSCF 501012FF Message No SMTP server specified Explanation A SMTP server has not been specified Replacement part number FF FF Action Specify a SMTP server Error level report level error detection source Notice 0 XSCF
159. dition descriptions are added to Chapter 6 Chapter 7 Chapter 8 Appendix D and Glossary Chapter 3 Connecting XSCF or Server In How to change the input output destination of OS console to tty a a description of the MODE switch the re setting is added at the 1 Changing the environment variable properties of NVRAM Chapter 10 XSCF Firmware Upgrade and Dump In Before upgrading firmware a description of the cluster system manual is added Summary of Changes in Seventh Edition The current seventh edition of this manual differs from previous edition principally by containing the corrections of descriptions about the error code The seventh edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition Preface In Important of About This Manual description which this manual can be referred to from a server path is deleted Chapter 6 How to Use the XSCF Command Shell Inset console device Caution for use is added Appendix B XSCF Log Information XSCF Error Log List are corrected Error codes 1300000X 1500000X 1600000X 1700000X 1800000X 1810003D 1820003D 190000FF 1A0000FF 1C00002n 1D00004n 1E0000XX 1F000044 21000045 230000FF 240000FF 250000FF 250000FF 2 2E200000 8E208900 C1001100 C1001200 C1001300 CE209900 DF000100 and DF001000 are corrected Error code numbers are corrected as
160. dog reset was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C1002100 Message SCFC access error addr xxxxxxxx Explanation An SCFC access error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C20107FF f Warning Message PSU type is not proper 0 DC 1 DC 2 AC l Explanation The type of PSU is not appropriate Replacement part number FF FF Action Check the PSU configuration Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C2040200 Message UPS alarm Explanation A battery error BPS was detected Replacement part number 81 UPS 00 Action Replace the UPS Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C3010000 Message THERMAL SENSOR Panel access error Explanation The system control bus detected an access error Replacement part number 02 PANEL 00 Action Replace the panel For models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C3020000 Message PANEL EEPROM access error Explanation The sy
161. e Warning 3 XSCF 8E07300n Message CPU n JTAG IDCODE xx differ from FRU IDCODE yy Explanation A CPU ID CODE error was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E208500 Message Error symptom CPU n 04 Explanation Logging errors when a CPU error symptom occurs Replacement part number FF FF Action Please check the errors occurred before or after Then perform it as follow Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 30 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 8E208600 Message Error symptom CPU n 02 Explanation Logging errors when a CPU error symptom occurs Replacement part number FF FF Action Please check the errors occurred before or after Then perform it as follow Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E208700 Message RC data error yy Explanation Analysis was not possible because a log request was issued in the RC data error state Replacement part number 01 SB 00 Action Replace the SB However if the error occurred after a failure to upgrade the firmware retry the upgrade If the upgrade still fails replace the SB Conta
162. e server OS console to serial port tty a Using this command without the option results in an error The required authority for this command is root level The following is an example of executing the command to set the serial port tty a SCF gt show console device TTY A Port lan SCF gt set console device serial SCF gt show console device TTY A Port serial SCF gt The following table describes the options that can be specified Table 6 4 set console device command options Option Description serial Sets the console destination to serial port tty a Note When you select which interface serial port tty a or SCF LAN port is used as Standard console OS console please set ports by Console Administration option of the Machine Administration Menu or scfconsole 1M command of the Machine Administration function If the Machine Administration function cannot be used or the console cannot be used via LAN port please use the console you can access from PC which is directly connected to XSCF by serial port tty a Then login to the XSCF Shell and set the console to serial with this command The command is at ESF2 5 1 or later For detail about the command see the Machine Administration Guide for the ESF Cautions for use If the the Standard Console has been set to serial port tty a from the Machine Administration Menu or on the command line of the Machine Administration function the Standard
163. e Firmware Upgrades the system uses the new updated firmware data Cluster configuration case of the System When the system is cluster configuration please update the firmware referring to the following document PRIMECLUSTER Trouble Shooting Guide In Chapter4 Maintenance see section Updating Operating environment Solaris 8 OS Solaris 9 OS Solaris 10 OS ESF 2 3 or later Upgrading firmware from the machine administration function The XSCF firmware is upgraded as a part of several firmware Upgrade firmware executed from the Machine Administration Menu that operates on the Solaris OS The operations guide for performing this operation is provided on the Machine Administration Menu For information about the Machine Administration Menu see the Machine Administration Guide for ESF The server has the following firmware XSCF firmware OBP firmware Disk firmware The basics of firmware upgrading from the machine administration function are provided below 10 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 10 1 Upgrading the XSCF Firmware Registration from CD ROM of Hardware Control Program HCP hereafter 1 Set the CD ROM of HCP 2 Start up the Machine Administration Menu usr sbin FJSVmadm madmin 3 Display Hardware Control Program HCP Administration menu from the Machine Administration Menu Machine Administration Menu Hardware Control P
164. e OS Machine Administration Menu XSCF administration Menu Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration The windows presented here are samples 3 Specify the Network Configuration Required IP address configuration Subnet mask configuration Gateway address configration XSCF Host name configuration 4 Register a user account Required Add or delete an XSCF account ID XXXXXXXXX Password XXXXXXXXX 5 Specify the Console Configuration Required Select Standard console Access control of console port Auto disconnect administration 2 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 1 XSCF Setup Flow 6 Configure the XSCF Web Optional but recommended because you can more easily manage the system from the remote Web browser Enable Disable XSCF Web Select locale Appearance of Web page Access control 7 Set up the SNMP configuration Optional but recommended if you have SNMP manager You can achieve consolidated management of system with using SNMP manager Port Setting Management Information sysContac sysName sysLocation Register community Delete community 8 Setup the Mail reporting function Optional but recommended because you can receive a mail from system in case of error Mailer Setting Server Setti
165. e configuration error 1 The message in parentheses is not displayed when the XSCF Web function and the XSCF Shell are used 2 These are the errors detected by only POST OBP To investigate the details of these system messages you can use the XSCF Web function and XSCF shell to view the error information that includes the error messages For information about viewing Web pages and using the XSCF commands see Chapter5 How to Use the XSCF Web Function and Chapter6 How to Use the XSCF Command Shell Error messages An error message is a detailed message from the server Purpose of system message is to report the event briefly and purpose of error message is to reports detail information of event such as the cause and a part number Error message is consist of up to 48 characters You can see the messages as a part of output from show error log command on XSCF shell For the list of error messages and corrective actions see the list of messages displayed by the show error logs command described in Appendix B XSCF Log Information Other information messages In addition to the above system messages and error messages there are also the information messages to display them on the OS console when a normal power on off and reset is performed 1 Initial diagnose messages Initial diagnose message is displayed on the OS console when a XSCF reset is done The initial diagnose message is displayed at the next cases Dis
166. e is sent to the center so that the REMCS Center manages the latest machine information Note XSCF don t need the Registration The Machine Administration function do the Registration Remote notification REMCS Agent constantly monitors the status of machines If a hardware failure occurs it is automatically detected and the REMCS Center is immediately notified of the abnormal event Information such as that in a log and memory dump required for incident analysis is sent to the center The temperature of the machine cabinet is continuously monitored and is periodically sent to the center as statistical information The center analyzes the received information to investigate the cause of the failure and monitors for foreseeable signs of another failure The remote notification function does not require any special operation by customers XSCF supports the remote notification function more strongly in cooperation with the Machine Administration function Investigation information collection If a problem occurs such as faulty operation of software and it cannot be automatically detected investigation Information can be collected in a simple operation and the information can be sent to the REMCS Center Note XSCF don t support this function The Investigation information collection is done on the Machine Administration function Reception of firmware At the time of periodic connection specified by a customer REMCS Agent is conn
167. e is the DC Type The type names of 01 PSU ON and 50 PSU OFF are added XSCF Event Log List are corrected Access Definitions of x50 x51 x52 and x53 about SSH are added Author Definitions of x50 x51 x52 and x53 about SSH are added RCI In the x10 The RCI sending event was executed and the x20 The RCI receiving event was executed the definitions of Byte1 or later are corrected RCI In the x30 The RCI initial operation was executed the definition of initial address is added And in the x31 The RCI initial configuration was executed and x32 The RCI initial configuration was executed again the definitions of Node ID are corrected Power event is added Appendix C XSCF MIB In Table Fujitsu extended TRAP apINetSCF is changed to scfObjects Appendix D Troubleshooting In Could not connect using telnet to XSCF via the SCF LAN descriptions of check items are added Could not connect using SSH to XSCF via the SCF LAN is added XSCF shell was suddenly disconnected while using SSH is added In Output on Standard console OS console connected to the LAN suddenly stopped a description about the processing for switching the standard console port OS console to the serial port tty a forcibly is added n A console the XSCF shell or a standard console was suddenly disconnected a description of Name Server Configu
168. e such as NTP is used the calendar timer of XSCF receives the influence Please refer to the manual of relating Solaris OS for details rci config The rci config command is used to view the RCI configuration information You may want to check the status of RCI by this command when for example you are setting up the system or you change the configuration of system For details of the RCI configuration information see Chapter 3 Connecting XSCF to Terminal The Machine Administration Menu also displays the RCI network list information For the RCI configuration information displayed by the Machine Administration Menu see the Machine Administration Guide for the ESF The following shows the format of the host address display and of the RCI configuration in the 6 24 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 5 XSCF Server Configuration Information Command RCI configuration information HOST Address Mode Status HOST shows the status of the host node in binary Address Address of the host device Mode Remote power supply control mode on the host Status Status of the device LIST address status device class sub class LIST lists the nodes in the RCI configuration in binary address Address of the device status Status of the device device class Device class sub class Device subclass The following is an example of command execution SCF gt rci conf ig HOST Add
169. e switching procedure 1 On the XSCF shell terminal screen execute the exit command to switch to the standard console 2 To switch from the standard console to the XSCF shell enter a tilde and a period default value Processing for switching the standard console port OS console When XSCF shell terminals and standard consoles are connected to both LAN ports and serial ports tty a as shown in Figure 3 1 the output destination port of the standard console screen can be switched with the Machine Administration Menu Since unlike an XSCF shell terminal a standard console cannot be used via both ports at the same time be sure to select one or other of the ports For the Machine Administration Menu used to select ports see Chapter2 Setting Up XSCF To change the output destination of the standard console connected via the LAN port to the serial port tty a use the following procedure 1 Ona Standard console that is connected to LAN port start up the Machine Administration Menu use the Console Administration option of the XSCF Administration Menu to set the output destination of the standard console to the serial port 2 From that point the standard console connected via the LAN port does not display the console Make sure that the standard console terminal connected via the serial port tty a displays the console To change the output destination of the standard console connected via the serial port tty a to
170. e system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE20010n Message Processor fatal error xxxxxxxx Explanation A CPU fatal error occurred Replacement part number 11 CPU 0 3 Action Replace the CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE20020n a Message Invalid adrs error 00000000 Explanation A CPU fatal error occurred The cause may be due to software Replacement part number 01 SB 00 or 11 CPU 0 3 Action Replace the CPU or SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE20040n ae Message Invalid interrupt error xxxxxxxx Explanation A CPU fatal error occurred The cause may be due to software Replacement part number 01 SB 00 or 11 CPU 0 3 Action Replace the CPU or SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE200700 Message DTAG error xxxxxxxx Explanation A fatal error occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE200900 Message Cache coherent error xxxxxxxx Explanation A fatal error occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection sour
171. eXtended System Control Facility User s Guide System Monitor and Control Facility eXtended System Control Facility XSCF User s Guide C120 E184 08ENZ2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Contents Preface iv About This Manual iv Summary of Changes in Eighth Edition vi Summary of Changes in Seventh Edition vi Summary of Changes in Sixth Edition vi Summary of Changes in Fifth Edition vii Summary of Changes in Fourth Edition viii Summary of Changes in Third Edition viii Summary of Changes in Second Edition x Summary of Changes in First Edition Revision xiii About UNIX Commands xiii About Notation in This Manual xiii Shell Prompts xiii About model name xiv Caution xiv Chapter1 Overview of XSCF 1 1 XSCF Features 1 2 Types of Connection to XSCF 1 5 XSCF User Interfaces 1 7 XSCF Monitoring and Linkage to Other Functions 1 9 Time synchronization 1 12 Chapter2 Setting Up XSCF 2 1 XSCF Setup Flow 2 2 Specifying the XSCF Settings 2 4 Network Configuration 2 4 User Account Administration 2 8 Console Administration 2 12 XSCF Web Administration 2 16 SNMP Administration 2 21 Mail Administration 2 25 REMCS Environment Setting via XSCF 2 31 SSH Administration 2 34 Chapter 3 Connecting XSCF or Server 3 1 Connecting Terminals to XSCF 3 2 Types of XSCF Connection 3 10 Connecting XSCF to PC and UPC 3 12 Connecting of RCI 3 13 Basic con
172. econds on the operation panel of the server Method 2 Push the power switch button for 10 seconds on the remote panel of the XSCF Web function Method 3 Issue the power off command by XSCF Shell Q5 What does the XSCF do from turning on the input power to OS starts The following is the process until the system starts up The input power source is turned on by operator XSCF starts The server is powered on and is initialized by XSCF POST starts and diagnoses the hardware OBP starts The boot process is started by OBP OS starts up AO Ue WN gt Q6 What messages are found on the screen when succeed in the XSCF login or XSCF logout The XSCF login success examples SCF Shell login root Password D 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 SCF Version xxxxxxxx ALL RIGHTS RESERVED COPYRIGHT C FUJITSU LIMITED 2003 192 168 1 2 The Login failure example SCF Shell login root Password ERROR Login incrrect The XSCF Logout success examples SCF gt exit logout The Logout failure example SCF gt exit Wrong name of Command Q7 want to check whether the XSCF e mail is sent by generating an error by XSCF What should I do Please issue logtest command by XSCF Shell Then the error is logged and e mail is sent For information about the XSCF shell commands see Chapter How to Use the XSCF Command Shell Note After checking the e mail you should clear the hard
173. ected to the REMCS Center If new firmware microprogram is available but not installed on the machines it is automatically received The firmware can also be downloaded manually Only in the models that support manual 9 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 9 1 Summary of XSCF REMCS Agent Function reception Using this function customers can maintain their firmware at the latest version For more information of firmware update see Chapter10 XSCF Firmware Update and Dump Note XSCF don t support this function The Reception of firmware is done on the Machine Administration function Next 9 2 Part of XSCF All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 9 XSCF REMCS Agent Function 9 2 Part of XSCF REMCS agent is a function installed in machine administration XSCF follows this function XSCF is used partially of this function The support can be strengthened further more by the XSCF function s joining the REMCS agent which has the conventional Machine Administration function It is because it is to have come to be able to correspond also to a serious problem such as system shutdown system can t start Customer Site REMCS Center Intemet Point to Point Data base REMCS agent XSCF Machine Administrati E Failure information SYSTEM Message DOWN Log information Figure 9 1 Example of REMCS report via XSCF Even if the system
174. ection source Warning 3 XSCF 84yyyy09 x Message Mount alarm XXXXXXXX CODE XXXXXXXX Explanation A mount error was detected Replacement part number A1 FF Action Check the installation status of the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 29 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 84yyyyF1 x Message RCI disconnected RCI is invalidated Code XX Explanation A communication error between RCI control circuits was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF 84yyyyF2 x Message RCI Status check timeout XXXXXXXX code YY Explanation An RCI network communication timeout error was detected Replacement part number A1 FF Action Check the RCI cable connection power supply of the connected device and the connection for RCI termination Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyyF3 x Message RCI neuron interface error code XXXX Explanation A RCI control circuits token error was detected Replacement part number A1 FF Action Check the RCI cable connection power supply of the connected device and the connection for RCI termination Contact the system
175. ed Specifying no community information is not allowed In the settings for community information you can specify whether to enable write operations to the writable MIB and whether to enable the issuing of traps Step 3 Enable the XSCF SNMP agent function Note If you modify the XSCF SNMP agent function settings be sure to start at the beginning with step 1 Next 7 5 Introduce Extended MIB of XSCF to SNMP Manager 7 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 7 XSCF SNMP Agent Function 7 5 Introduce Extended MIB of XSCF to SNMP Manager This section briefly explains procedures to introduce extended MIB of XSCF into two kinds of SNMP manager WebSysAdmin and SystemWalker Please refer to the manual of each application for details of installation method 7 5 1 Installation case to WebSysAdmin This work must be done with the workstation in which WeabSysAdmiin is installed Step 1 Make the temporary directory In this example tmp primepower_xscf and copy XSCF extended MIB file from the directory in which XSCF extended MIB is installed mkdir tmp pr imepower_xscf cd tmp pr imepower_xscf cp opt FUSVhcp mib pr imepower_xscf dat H Note The MIB file can be refferred to from the following path in the HCP CD too PWPO MIB Step 2 Backup the current MIB file to the file that you specified In this example etc snmp mgr snmpinfo dat bak It returns to
176. ed command The following is an example of command execution ae XSCF Parts Error Information Parts Error Message Os meee Fd ee ae eT TT CPU O Uncorrec error Internal 008f024f SB Uncorrec error Marked 008f021d show mail report The show mail report command is used to view the information of XSCF Mail Administration For example it can be used to display whether the mail report function is valid or invalid Mail destination address Sender address SMTP server name POP authentication server etc The following is an example of command execution SCF gt show mai l report kk Mail Report configuration mai ENABLE status gt ACTIVE E Mail address to mai l address domain name co jp 6 10 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 E Mail address from 6 3 Server Status and Control Commands root domain name co jp smtp 1 server smtp server pop 1 authentication VALID pop 1 server pop server pop 1 user pop user name pop 1 wait time 300 msec smtp 2 server pes pop 2 authentication pop 2 server Doe pop 2 user 2 pop 2 wait time Doe name server gt 192 168 1 1 show remcs The show remcs command is used to view the information of REMCS Environment Setting via XSCF For example it can be used to display whether the REMCS report function via XSCF is valid or invalid Model type name Sender address SMTP serv
177. ed the test normally For information about the SMTP server the POP authentication server and the Name server settings see Chapter2 Setting Up XSCF The command is at ESF2 5 1 or later For detail about the command see the Machine Administration Guide for the ESF Next 8 2 Reporting Parts Faults All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 8 XSCF Mail Function 8 2 Reporting Parts Faults XSCF monitors the parts in the server including the CPU fan and system board If an error occurs for any of these parts XSCF sends an e mail notification to the system administrator In the following figure XSCF reports parts faults to the system administrator by mail Fault notification aS System administrator 4 fault occurs Figure 8 2 XSCF fault information 8 3 Reporting an Authentication Failure All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 8 3 Reporting an Authentication Failure 8 3 Reporting an Authentication Failure If unauthorized access to the SCF LAN is attempted XSCF sends an e mail notification to the system administrator In the following figure XSCF reports an authentication failure to the system administrator by e mail Five consecutive password input failures Eca wa failure notification administrator Figure 8 3 XSCF authentication failure notification Next 8 4 Setting up the XSCF Mail Function 8 5 All Rights Reserved Copyright C
178. efore Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E20F800 Message Instruction retry xxxxxxxx Explanation The instruction retry was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E20FA00 Message Watchdog timeout xxxxxxxx Explanation A watchdog timeout was detected Replacement part number 01 SB 00 Action Replace the SB Or Replace the CPU Or Replace the PCl Card Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8E20FBOn Message Bus protocol error xxxxxxxx Explanation A fatal error occurred Replacement part number 11 CPU 0 3 Action Replace the CPU or SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 31 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 9080000n Message Parts Status Reset Failure Explanation In Machine Administration Menu the status of abnormal parts was reset Replacement part number M Action Replace the replacement part Contact the system administrator or a FE Error level report level error detection source Warning 0 XSCF C0800E00 Message SCF CPU WATCHDOG reset Explanation A watch
179. egal Instruction storage interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800400 Message SCF CPU Illegal External interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800500 Message SCF CPU Illegal Alignment interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C0800600 Message SCF CPU Illegal Program interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800700 Message SCF CPU Illegal System call interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800800 Message SCF CPU Illegal PIT int
180. elete other account repeate the same procedure When no account is registered you will see following screens 2 10 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Delete User q Quit b Back to previous menu t Go to topmenu h Help There is no registered user You cannot delete Hit return key Menu point will return to User Account Administration by pressing return Update Password To change password choose Update Password from User Account Administration menu Examples Update Password lt user gt lt group gt others others Select user 1 q b t h 2 Return Do you really want to update the password y n y Return New password XXXXXXXXXX Return Re enter new password xxxxxxXXXX Return Password was updated Hit return key When you press the return key then it goes back to Update Password menu To update setting of other account repeat same procedure Setting on the command line The User Account Administration can also be set by using the scfuser 1M command of the Machine Administration function Use the scfstat 1M command to display the configuration information When you set up the User Account Administration on the command line please perform the scfreset 1M command to reflect the setting For details of these three commands of the Machine Administration function see the command reference in the Machine Administration Guide f
181. elnet connect ion or SSH connect ion or Router Router m http connect ion m Hail ol YPN communication SCF LAN port Server Serial port Figure 3 5 Connection of external Internet using VPN communication For the security reason using Virtual Private Network VPN as for external network is strongly recommended Connecting XSCF to the serial port tty a You can use XSCF by connecting to the serial port tty a The XSCF connection to the serial port is also shown in Figure 3 1 The following XSCF functions are available when it is connected to the serial port Also listed the advantage of such a connection XSCF shell function Advantageous when connection to the LAN is not desirable for reasons of security Connecting XSCF to both the LAN port and the serial port tty a XSCF is connected to both the LAN port and the serial port tty a This type of connection is also shown in Figure 3 1 XSCF when connected to both ports has the following advantage in addition to the functions described for connection to the LAN port Multiple users can use the XSCF shell function Next 3 3 Connecting XSCF to a PC and UPC All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server 3 3 Connecting XSCF to a PC and UPC It describes how to connect XSCF with PC and UPC UPS I F Power supply control box FS 10PW2 Out let wy Socket 125V 154 ug Figure 3 6 Connected ch
182. emote Cabinet Interface The RCI is the power and system control interface that connects units including processors and expansion file units and performs such functions as power supply interlock and alarm notification and recognition W 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 RCI address The address by which each device used by the RCI is recognized RCI device or RCI I O A device connected by the RCI The server external power controller disk drive and circuit switch are some of the devices connected by the RCI RCl Neuron A chip that controls the RCI Neuron Read only console An OS console used for display only On a terminal connected to the SCF LAN starting telnet and specifying port number 8011 or 8013 establishes a connection 8011 port can be used by up to two users per server 8013 port can be used by only one user per server Used only as the remote console port When you use the SSH function specify port number 8811 or 8812 Each SSH port can be used by only one user per server Since the Read only console is independent of the console switching executed by the XSCF command the console display is available at all while the OS is running REMCS An abbreviation of REMote Customer Support System This System use the REMCS agent which is software we developed to use REMCS This provides an advanced remote support service by connecting the user s server with the REMCS center by the Internet I
183. emote location you can even use console from the remote location 2 errors or failures will be reported to the system administrator automatically XSCF has the following features 1 Power control XSCF can be used to turn on or off server power as indicated below in addition to the power button on the operating panel Remote operation for power on power off and reset You can turn on turn off or reset the server with using the XSCF shell command or the remote panel of the XSCF Web function from a remote terminal which is connected to XSCF over a LAN When you instruct power off system will execute shutdown of OS then the power will be turned off For information about the XSCF shell see Chapter6 How to Use the XSCF Command Shell For information about the XSCF Web function see Chapter5 How to Use the XSCF Web Function Cancelling power on when an error is detected This feature automatically shuts down the OS and prevents implementation of the poweron sequence if a system error occurs to minimize the effects of the error on the system OS startup control for power failure XSCF performs the operations below if a power failure that causes the server to turn off occurs When a power failure occurs XSCF automatically shuts down the OS If there is no uninterruptible power supply unit UPS XSCF performs emergency power off Fora momentary power failure XSCF may allow system to continue working without any shutting do
184. end a mail but cannot receive Test Mail You can conduct a mailing test 2 25 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Mailing test After making the settings above you can conduct a mailing test After sending a test e mail message confirm that the test message is delivered to the all of the destination addresses Mail Administration menu operation In the beginning choose Mai Administration in XSCF Administration menu of the Machine Administration Menu Examples XSCF Administration 1 Network Configuration 2 User Account Administration 3 Console Administration 4 XSCF Web Administration 5 SNMP Administration 6 Mail Administration q Quit b Back to previous menu t Go to topmenu h Help Select 1 6 q b t h 6 Mailer setting Next choose Details Setup of the Mail in Mail Administration menu And enable the mail report function Examples Mail Administration 1 Show Current Configuration 2 Details Setup of the Mail 3 Send Test Mail q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 q b t h 2 Next Details Setup of the Mail Mail Report disable 1 Enable Mail Report and Setup 2 Disable Mail Report q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 1 Please follow the instruction of the next screen until the setting is completed Server setting Mail desti
185. ension Mail Notification is added Chapter 10 Troubleshooting This is moved to Appendix D Appendix B XSCF Log Information XSCF Error Log List are corrected or added Description of error code 8E20F40n is corrected Error code 8E20FB0n is added XSCF Power Log List are corrected added or deleted 40 Shutdown ALM is corrected to 41 Shutdown ALM Shutdown ALM In the Power supply monitoring and Temperature monitoring definition the because of sensor error are added Power off In the Power supply monitoring definition the because of sensor error is deleted Appendix D Glossary Finding Appendix is deleted About UNIX Commands This manual does not include a description of general UNIX TM commands Refer to the documentation supplied with the software used by the system About Notation in This Manual Table P 1 Notation Item Use and example Use The characters coded in a command displayed on the OS console and the variables in a command option are indicated in italic Xx123 Example The prompt on the server s OS console changes to ok env monitor scsi_bpn n 0 1 Use The titles of chapters and tables and terms that are being Xx123 emphasized indicated in bold Example 6 6 Other Commands Shell Prompts Table P 2 Shell prompts Shell Prompt eXtended system Control Facility SCF gt xiii All Rights Reserved Copyright C FUJITSU
186. ent scfHWConfAddr scfHardware scfObjects scfServerName An Faulty part was exchanged ErrorUnset 1 3 6 1 4 1 21 6 scfTrapTime and as a result all the faulty parts 1 1 15 2 1 scfHWErrComment in the server disappeared scfHWConfAddr scfAgentStart scfObjects scfServerName The agent function was started 1 3 6 1 4 1 21 6 1 1 15 2 1 scfHardware scfObjects scfServerName An Warning level Faulty part was ErrorRepair 1 3 6 1 4 1 21 6 scfTrapTime exchanged but any Faulty parts still 1 1 15 2 1 scfHWErrComment remains in the server scfHWConfAddr scfHardware scfObjects scfServerName An Alarm level Faulty part was DefectRepair 1 3 6 1 4 1 21 6 scfTrapTime exchanged but any Alarm level 1 1 15 2 1 scfHWErrComment parts still remains in the server scfHWConfAddr 1 The fatal problem that the system cannot continue operation 2 The slight problem that the system can continue operation C 9 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Next Appendix D Trouble shooting All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Appendix D Troubleshooting This chapter describes problems that can occur during use of the XSCF console or during operation of the system and provides solutions for them This chapter has the following contents Contents D 1 Troubleshooting XSCF and FAQ D 2 D 2 Troubleshooting the Server While XSCF Is Being Used D 9 All Rights Reser
187. ent Configuration 2 Enable Disable XSCF Web 3 Select Locale 4 Appearance of Web Page 5 Access Control q Quit b Back to previous menu t Go to topmenu h Help Select 1 5 q b t h 2 Next Enable Disable XSCF Web Current Configuration disable 1 Enable with read write mode 2 Enable with read only mode 3 Disable q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 q b t h 1 Next Enable Disable XSCF Web Current Configuration enable with read write mode 1 Enable with read write mode 2 Enable with read only mode 3 Disable q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 q b t h 1 Return Enable with read write mode Are you sure y n y Return Setting has completed Hit return key Select Locale Next configure Select Locale in XSCF Web Administration menu Examples Select Locale Current Locale C english 1 C english 2 ja japanese q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Next Select Locale Current Locale ja japanese 1 C english 2 ja japanese q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 2 Return Are you sure y n y Return Setting has completed Hit return key Appearance of Web Page Next choose Appearance of Web Page in XSCF Web Administratio
188. ent that enables the SNMP manager to centrally manage the operating status and fault status of terminals on the network SNMP trap A trap issued by the SNMP manager SSH An abbreviation of secure shell Ahigh security remote shell mechanism that encrypts data that will be transmitted on the Internet All communication route can be encrypted by using SSH when you use the function of shell such as TELNET and rsh by remote operation so you can prevent packet tapping SSL An abbreviation of secure socket layer Asecurity mechanism that encrypts data that will be transmitted on the Internet Netscape Navigator and Microsoft Internet Explorer support SSL When a Web page ready for SSL is accessed the key symbol in the browser is locked and a warning message is displayed Standard console An OS console on which input and output are enabled The OS console can be used in both an SCF LAN connection and a serial connection On a terminal connected to the SCF LAN starting telnet and specifying port number 23 establishes a connection When SSH is used the port number is 22 The standard console can also be used by connecting a PC to the serial port and turning on the server Only one user per server can use the LAN port of the standard console On the Machine Administration Menu or the command of the Machine Administration function you can select whether to use a standard console via the serial port tty a or the SCF LAN port The comman
189. er Category Replacement part Parts number number hex 01 SB board 0 02 PANEL board 0 03 PCI board 0 04 SCSI BP SCSI Back Panel O 1 05 PCI RISER 0 11 CPU 0 3 21 SLOT memory 00 15 22 SLOT group 00 15 31 FAN O 7 32 FAN board O 1 41 PSU 0 2 42 CPUDDC 0 3 43 DDC A DDC12 0 44 DDC B DDC21 0 81 UPS 0 82 SDU Used by ESF 83 BATTERY Used by ESF 91 DISK 0 5 92 PCI slot 00 08 93 TAPE Used by ESF al RCI FF hex FD U2P Not replacement part 0 2 3 FE Error log for test FF hex FF Cannot specified FF hex IO BP 0 POWER BD 0 PSU CAGE 0 The pair of replacement SLOT number are 00 01 02 03 14 15 Next B 2 XSCF Power Log List All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 2 XSCF Power Log List This section lists all power log information displayed when the show power logs command is executed on the XSCF console The following table explains the items in the power log list For information about a command to display power log and options to the command see Chapter6 How to Use the XSCF Command Shell Table B 2 1 How to read the power log list Type Type of power log and unique code for the type Ss The hardware source that generated the power event and the unique ource code Detailed code Detailed code in the power log Explanation Explains the meaning of the
190. er FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101110n Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101120n Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101130n Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed SMTP server n was not found Replacement part number FF FF Action Recheck the SMTP server Error level report level error detection source Notice 0 XSCF 6101140n Message Mail communication to name server timeout Explanation Name Resolution of SMTP server failed The timeout occurred by the Name server Replacement part number FF FF Action Recheck the SMTP server or the Name server Er
191. er are added Chapter 6 How to Use the XSCF Command Shell Inset console device lan option is deleted The command of send break is added Appendix A Warning And Information Messages System messages are corrected Hardware configuration error is added RCI address is added in Detected failure on the RCI node Messages of the errors detected by only POST OBP are added All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 The description about the message which is not displayed partially is added Appendix B XSCF Log Information XSCF Error Log List are corrected Error codes 281000XX C1001300 C203030n and FFOOOOFF are added Error codes 8E07200n C1001200 and FEOOOOFF are corrected XSCF Power Log List are added XIR In the Source definition ACK timeout is added Error code number is corrected as below C311000n gt 8311000n C3120000 gt 83120000 C313000n gt 8313000n C314000n gt 8314000n XSCF Event Log List are corrected Unit configuration change A definition of x81 is added Appendix D Troubleshooting In Troubleshooting XSCF and FAQ descriptions of FAQ are added In Troubleshooting the Server While XSCF Is Being Used are corrected Glossary Inthe term Standard consol Not to use the XSCF command to set whether to use a standard console via the serial port tty a or the SCF LAN port but to do b
192. er name POP authentication server etc The following is an example of command execution SCF gt show remcs aee REMCS configuration REMCS gt ENABLE status gt ACTIVE remcs test fault code 00 remcs version gt VO6L01E0001 connection model gt INTERNET machine id gt OOPRIMEPWRHPHHPWOLBS1 1 1 MH345678HHHHHH message code 00 E Mail address from mail address domain name co jp smtp 1 server smtp server pop 1 server pop server pop 1 user user name pop 1 wait time 2000 msec smtp 2 server Odes pop 2 server ects pop 2 user ae pop 2 wait time me name server lt 192 168 1 1 show console device The show console device command on the XSCF console is used to display whether the current destination of the server OS console is on the SCF LAN or is the serial port tty a The following is an example of command execution SCF gt show console device TTY A Port serial SCF gt Note 6 11 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell We strongly recommend that you should set the input output destination of the OS console to the tty a Especially when you use the graphic card For more detail about changing the console to tty a see Chapter3 Connecting XSCF or Server set console device serial The set console device command in the XSCF console is used to change the current destination of the Standard consol
193. er on was executed via the LAN Source 11 LAN Detailed code x81000000 Explanation Power on was executed via the LAN An XSCF requests power on of external facility Source 11 LAN Detailed code x82000000 Explanation Power on was executed via the LAN A delayed startup of the system was performed Source 12 TTY Detailed code x00000000 Explanation Power on was executed via TTY Source 12 TTY Detailed code x81000000 Explanation Power on was executed via TTY An XSCF requests power on of external facility Source 12 TTY Detailed code x82000000 Explanation Power on was executed via TTY A delayed startup of the system was performed Source 13 PC Detailed code x00000000 Explanation Power on was executed by the PC interface Source 13 PC Detailed code x81000000 Explanation Power on was executed by the PC interface An XSCF requests power on of external facility B 64 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Source 13 PC Detailed code x82000000 Explanation Power on was executed by the PC interface A delayed startup of the system was performed Source 17 RCI Host Detailed code xXX000000 Explanation Power on was requested by the RCI Host XX indicates the node number of RCI Host which request power on to this system Source 17 RCI Host Detailed code x81000000 Explanation Power on was executed by the RCI Host An XSCF requests power on of
194. erial port Connection to the serial port Terminal Figure 1 1 Connections to XSCF Note We strongly recommend that you should set the input output destination of the OS console to the tty a Especially when you use the graphic card For more detail about changing the console to tty a see Chapter3 Connecting XSCF or Server Figure 1 1 1 shows the tty a console path OS POST OBP SC F LAWN port Seral port tha Figure 1 1 1 tty a console path 1 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter1 Overview of XSCF 1 6 The console Interface between OS POST OBP and SCF is called tty a As shown in Figure 1 1 1 the input output destination of the OS POST OBP console is devided into two ports in XSCF Thus it is possible to choose serial port tty a or SCF LAN port as a tty a console For the input output destination of the console use the Console Administraiotn of the Machine Administration Menu to select one or the other For the Machine Administration Menu used to select ports see Chapter2 Setting Up XSCF As shown in Figure 1 1 there are two types of connections to XSCF Serial port tty a SCF LAN Ethernet Serial port tty a The serial port enables UNIX workstations Windows PCs and ASCII terminals to connect to XSCF through the serial RS 232C port The XSCF shell can be used with the serial port SCF LAN Ethernet SCF LAN Ethernet enables UNIX workstations
195. error factors Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 CE209900 Message Hardware no error region xxxxxxxx Explanation Analysis is not possible because there are no error factors Replacement part number FF FF Action Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE20F10n Message Fatal error Internal xxxxxxxx Explanation A fatal error occurred Replacement part number 11 CPU 0 3 or 01 SB 00 Action For the Replacement part is CPU Replace the CPU Or Replace the SB For the Replacement part is SB Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF eeetreee Message Fatal error Outside xxxxxxxx Explanation A fatal error occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE20FB00 Message Bus protocol error xxxxxxxx Explanation A fatal error occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detec
196. errupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800900 Message SCF CPU Illegal FIT interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800A00 Message SCF CPU Illegal WDT interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800B00 Message SCF CPU Illegal Data TLB miss interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800C00 Message SCF CPU Illegal Instruction TLB miss interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800D00 Message SCF CPU Illegal Debug interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the
197. erver Name Server2 Save Configuration c OORUN q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 4 Return Enter New Host Name with alphanumeric characters a z A Z 0 9 hyphen and period This needs to enter FQDN Input example com Name Server Next choose Name Server1 in Network Configuration menu by number Examples Network Configuration IP Address 192 168 1 10 Subnet Mask 255 255 255 0 Gateway Address 192 168 1 1 XSCF Host Name example com Name Server Name Server2 Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 5 Return Enter the Address of Name Server 1 192 168 1 1 2 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Next Network Configuration IP Address 192 168 1 10 Subnet Mask 255 255 255 0 Gateway Address 192 168 1 1 XSCF Host Name example com Name Server1 192 168 1 1 Name Server2 Save configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h u Return Are you sure y n y Return Setting has completed Hit return key Setting on the command line The Network Configuration can also be set by using the scfconsole 1M command of the Machine Administration function Use the scfstat 1M command to display the configuration information When you set up the Ne
198. esolution of POP server failed The Name server was not specified Replacement part number FF FF Action Specify the Name server Error level report level error detection source Notice 0 XSCF 6110210n Message REMCS communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF B 55 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6110220n Message REMCS authentication of POP server n failed Explanation The authentication failure in POP server n occurred Replacement part number FF FF Action Recheck the POP server name or the POP user name or password Error level report level error detection source Notice 0 XSCF 6110230n Message REMCS communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Recheck the POP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110240n Message REMCS communication to POP server n timeout Explanation The timeout occurred by the POP server n Replacement part number FF FF Action Recheck the POP
199. ess status The logins to XSCF Web function pages can be checked Next Chapter6 How to Use the XSCF Command Shell 5 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter6 How to Use the XSCF Command Shell This chapter explains how to use the XSCF command shell This chapter has the following contents Contents 6 1 Overview of XSCF Command Shell 6 2 Login to XSCF User Account 6 3 Server Status and Control Commands 6 4 XSCF Log View Command 6 5 XSCF Server Configuration Information Command 6 6 Other XSCF Commands 6 7 XSCF Shell Error Messages All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 2 6 4 6 7 6 16 6 24 6 28 6 32 6 1 Chapter 6 How to Use the XSCF Command Shell 6 1 Overview of XSCF Command Shell When XSCF commands are executed on the XSCF console the server status is displayed and control and configuration information related to server operation can be viewed These XSCF functions and types of information are also available on Web pages displayed with the XSCF Web function When a registered user uses the XSCF console but cannot use the XSCF Web function the XSCF commands are effective Use the XSCF commands at the XSCF shell prompt SCF gt which is displayed after login to the user account for XSCF XSCF account hereinafter This chapter explains how to log in to the XSCF account how to use commands and the 6 2 command errors that can occur
200. essage is displayed on the OS console when a normal power off is performed Start power off sequence Code 02020100 Continue to rotate FANs XXX min Display when the delayed startup of FAN is set Code 02020200 Power off Code 02020300 Complete power off sequence Code 02020400 Figure A 3 Normal power off messages 4 Normal reset messages The following information message is displayed on the OS console when a normal reset is performed Start reset sequence xxx xxx POR XIR Code 02030100 Reset released Code 02030200 Figure A 4 Normal reset messages All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 5 FATAL log collection messages XSCEF collects a log when a FATAL CPU error has occurred At that time the following FATAL log collection messages is displayed on the OS console Getting SC Register data SC register data getting 1 Code 0E040100 Getting XB X Register data XB X register data getting 1 Code 0E040200 Getting CPU X some scan data CPU X sk hk data getting 1 Code 0E040300 Getting SC History data about XXX sec SC lt history data getting 1 Code 0 040400 Getting CPU X History data about XXX sec CPU X history data getting 1 Code 0 040500 Getting CPU X All Scan data CPU X all scan data getting 1 Code 0 040600 Getting SC All Scan data SC allscandata getting 1 Code 0E040700 Getting XB X All Scan data XB X all scan da
201. et XSCF WEB Command Line C Program Files Internet Explorer iexplore exe https IP This is a example Please set a browser used Add Operation Menu message box is displayed Step 13 Click OK button Add Operation Menu dialog box close Step 14 Reboot the System Monitor of SystemWalker Step 15 We will be able to use new menu item XSCF WEB by the following methods 7 9 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 7 XSCF SNMP Agent Function Tools menu Specific Node System item XSCF WEB item XSCF WEB is started on a specified browser The installation on XSCF extended MIB is completed by this Next Chapter 8 XSCF Mail Function 7 10 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 8 XSCF Mail Function This chapter describes the XSCF mail function This chapter has the following contents Contents 8 1 Overview of XSCF Mail Function 8 2 Reporting Parts Faults 8 3 Reporting an Authentication Failure 8 4 Setting up the XSCF Mail Function 8 5 Contents of Parts Fault Notification 8 6 Contents of Authentication Failure Notification 8 7 Contents of Test Mail Notification 8 8 Contents of Suspension Mail Notification All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 8 2 8 4 8 5 8 6 8 7 8 9 8 10 8 11 8 1 Chapter 8 XSCF Mail Function 8 1 Overview of XSCF Mail Function This syste
202. et is POR was requested from CPU Source 08 FATAL Detailed code x00000000 Explanation A reset type of reset is POR was requested due to detection of FATAL Source Ob ACK timeout Detailed code x00000000 Explanation A reset type of reset is POR was requested due to timeout of communication ACK timeout Source 11 LAN Detailed code x00000000 Explanation A reset type of reset is POR was requested via LAN Source 12 TTY Detailed code x00000000 Explanation A reset type of reset is POR was requested via TTY Source 17 RCI Host Detailed code xXX000000 Explanation A reset type of reset is POR was requested from RCI HOST XX indicates the node number of RCI HOST which request reset to this system Source 18 HTTP Detailed code x00000000 Explanation A reset type of reset is POR was requested via HTTP Source 80 Retry Detailed code x01000000 Explanation A reset type of reset is POR was requested due to retry against FATAL problem Source 80 Retry Detailed code x02000000 Explanation A reset type of reset is POR was requested due to failure of alive check Source 81 SCF Self Detailed code x00000000 Explanation A reset type of reset is POR was requested via SCF 3f Reset Release Source ff Nothing Detailed code x00000000 Explanation The reset state was released 40 Shutdown NML Normal system Source 00 PANEL SWITCH Detailed code x
203. etection source Notice 0 XSCF 6101320n Sani Message Mail communication to SMTP server n timeout Explanation The timeout occurred by the SMTP server n Replacement part number FF FF Action Recheck the SMTP server Error level report level error detection source Notice 0 XSCF 6101330n Message Mail communication to SMTP server n failed Explanation The communication failure to SMTP server n occurred Replacement part number FF FF Action Recheck the SMTP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101340n o Message Mail communication to SMTP server n failed Explanation The communication failure to SMTP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110000n i Message REMCS illegal POP server n specified Explanation An illegal POP server name was specified Replacement part number FF FF Action Recheck the POP server name Error level report level error detection source Notice 0 XSCF 6110100n Message REMCS Name Resolution of POP server n failed Explanation Name Resolution of POP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report
204. f an error will occur system send the error information which is needed to the REMCS center immediately In addition XSCF send the information to REMCS center even if system is down RS 232C An interface standard used to connect a PC to another PC or to a peripheral device for the purpose of exchanging data The standard established by the Electronic Industries Association EIA in the United States is used by most PCs as the usual input and output serial interface The interface can be used to connect a PC to a printer plotter mouse and similar devices SB An abbreviation of system board SC An abbreviation of system controller The SC controls the coherency of the cache among CPUs SCF An abbreviation of System Control Facility The SCF is the system monitoring and control facility It is the same facility as XSCF SCFC Achip that can be programmed for the SCF function SCF FMEM An FMEM for the SCF firmware SCF SDRAM An SDRAM for the SCF firmware SCSI BP A SCSI board SDRAM An abbreviation of synchronous DRAM SLOT See DIMM SMTP An abbreviation of Simple Mail Transfer Protocol SMTP is a protocol for sending e mail on the Internet or an intranet It is used to transmit mail between servers and to send mail from a client to the server All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 SNMP An abbreviation of Simple Network Manager Protocol SNMP is a protocol for network managem
205. figration 3 13 Cluster Configration 3 14 Method of configration of RCI 3 15 How to change the input output destination of OS console to tty a 3 17 Chapter4 How to Use the Remote Panels 4 1 Overview of the Remote Panels 4 2 How to Use the Remote Panels 4 4 LED Indicators on the Remote Panels 4 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Differences from the Operating Panels Chapter5 How to Use the XSCF Web Function Overview of the XSCF Web Function Starting the XSCF Web Function Logging In to or Out from XSCF XSCF Web Function Pages Chapter6 How to Use the XSCF Command Shell Overview of XSCF Command Shell Login to XSCF User Account Server Status and Control Commands XSCF Log View Command XSCF Server Configuration Information Command Other XSCF Commands XSCF Shell Error Messages Chapter7 XSCF SNMP Agent Function Summary of XSCF SNMP Agent Function About MIB About Traps How to Set up the XSCF SNMP Agent Function Introduce Extended MIB of XSCF to SNMP Manager Installation case to WebSysAdmin Installation case to SystemWalker Chapter 8 XSCF Mail Function Overview of XSCF Mail Function Reporting Parts Faults Reporting an Authentication Failure Setting up the XSCF Mail Function Contents of Parts Fault Notification Contents of Authentication Failure Notification Contents of Test Mail Notification Contents of Suspension Mail Notification Chapter 9 XSCF REMCS Agent Function Summary of XSCF REMCS Agent
206. figuration takes effect after the next server reset Caution After you perfom the operation 2 the result is that CDE screen is not Console anymore so you can t log in from this screen by root Use following configuration to allow root to sign on from CDE if needed 1 Log in from the tty terminal 2 Perform the below setting and you can log in from the CDE Update file etc default login Changing Coment out the 15th line of this file as below CONSOLE dev console Next Chapter4 How to Use the Remote Panels All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 4 How to Use the Remote Panel This chapter describes the Remote Panel that can be used on the XSCF Web function and explains how to use them This chapter has the following contents Contents 4 1 Overview of the Remote Panel 4 2 Howto Use the Remote Panel 4 3 LED Indicators on the Remote Panel 4 4 Differences from the Operating Panel All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 2 4 4 4 7 4 9 Chapter 4 How to Use the Remote Panel 4 1 4 2 Overview of the Remote Panel By accessing the remote Panel from the XSCF Web function page view you can check the LED indicators to determine the operating status of the server and can control server power from a remote location The remote Panel provide Web browser based access to the server s operating panel that are in the front and the rear of server f
207. for more information The following table shows the details of collected log information by Machine Administration Menu For reference purposes the table also shows the maximum size of the logs that can be displayed by the XSCF shell Table 10 1 XSCF dump and types of XSCF logs Reference Type of Maximum size data Obtained data displayed by XSCF shell Dum Three generations of a XSCF dump maximum _ P 32 megabyte each Log Error log 2 KByte Power log 0 5KByte 10 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 10 2 How to Get XSCF Dump Information and Collect Logs Event log 8 KByte Temperature history log 2 KByte Access log 1 KByte Note The dump file and log files are compressed Some additional log files which are logged by Machine Administration Menu but not listed in the above table are included to the collected log For the trigger for obtaining each log type and the maximum capacity for each log file required to save the log data see the Machine Administration Guide for ESF Next Appendix A Warning And Information Messages 10 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 10 XSCF Firmware Upgrade and Dump 10 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Appendix A Warning And Information Messages This appendix explains the error notification messages that XSCF outputs to the server OS c
208. g this opiton display the log starting from the latest Display the log of specified size Value has to be designated in hexadecimal format Ommitting this option display 8KB size log Maximum 16KB can be Note This log can be shown only when OS console port is set to the SCF LAN port or the serial port tty a Next 6 5 XSCF Server Configuration Information Command 6 23 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 6 5 XSCF Server Configuration Information Command Use the following XSCF shell commands to view the server configuration information for example number of CPUs and memory capacity date rci config show config lan config date The date command is used to display the current time and date The time cannot be specified The following shows the format of one line yyyy mm dd HH MM SS TimeZoneName yyyy Year mm Month dd Day inthe month HH Hour 24 hour system MM Minute SS Second TimeZoneName Display the name of the local time zone Maximum 8 charactors The following is an example of command execution SCF gt date 2002 08 13 11 41 40 JST SCF gt Note The date and time displayed by the date command are local time Time cannot be set from the XSCF shell Please use and set the command of Solaris OS such as Date When the utility of Solaris OS which controls the tim
209. gs 2 Mail address specified as the destination mail address in the mail settings For the above settings see Chapter2 Setting Up XSCF 3 Host name of XSCF 4 Fault level of the faulty part which is one of the following A Fault or abnormal condition Alarm W Part degraded or warning Warning Notification Information 5 Faulty part n indicates the part number For the types of parts see Table B 1 P of AppendixB For information about part names see Glossary 6 Hardware unit where the fault was detected SCF POST OBP 7 Message output by the system For the meaning of messages see Appendix A Warning Messages 8 Time at which the fault occurred The time is the local time 9 Error code For the error codes see Appendix B XSCF Log Information 10 Serial number of the faulty part All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 8 XSCF Mail Function 11 Error message For the error messages see Appendix B XSCF Log Information 12 Fault level of the system which is one of the following ALARM Fatal problem for system EPOFF Emergency power off STOP Emergency shutdown UNABLE TO START The system could not be stated WARNING Serious problem but system can keep working NOTICE Notification Next 8 6 Contents of Authentication Failure Notification 8 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 8 6 Contents
210. h ows the format of a line in the access log 6 19 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell DATE TIME UserlID TYPE IP Address DATE Date on which a network port such as the XSCF Web function or SCF LAN port was accessed TIME Time local time when s network port such as the XSCF Web function or SCF LAN port was accessed UserID Accessed port ID User IP address The following is an example of command execution SCF gt show access logs Date TIME ID TYPE IP address 4 4 4 4 2002 09 10 09 18 52 user01 Telnet port 8010 11 22 33 4 2002 09 12 09 18 52 guest Telnet port 8010 123 123 123 123 2002 09 14 09 18 52 root Serial RS232C 2002 09 15 09 18 52 user01 SSL Port 443 li 22 004 SCF gt Note The TYPE values include telnet SSH SNMP RS232C serial SSL and http thermal history g va ue The thermal history command is used to view a history of the ambient server temperature CPU temperature and temperature of the system board When the g option is specified the history is represented graphically When no options are specified all temperature histories are listed in a table To display the temperature history for each device enter the specification option in the table given below The logged information can be remains for about one day Older information will be expired Theref
211. h the request switch and execute the crash dump when the system has been no responses etc or it is necessary to reset the system unavoidably After the crash dump is gathered the system is reset Whenever you reset the server the Web browser window is refreshed at intervals of about 10 seconds Resetting the server while the OS is running can damage the disk containing the OS Use care when using the reset switch on the front remote panel Request switch Press the request switch button on the front remote panel to request output of an crash dump to OS To be able to performe this switch operation set Enable with read write mode and log in XSCEF with root level authority Note The request switch causes the system panic for the crash dump collection This operation is a maintenance operation of the system investigation etc and has the possibility of destroying the file system when panic is requested while OS is accessing the file system Therefore please do not operate it except when it is necessary to gather the crash dump due to the system investigation purpose or the abnormality such as without the response from the system The crash 4 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 4 How to Use the Remote Panel dump might not be able to be gathered according to the state of the system Mode switch The mode switch on the front remote panel indicates the state of the slide switch on the server s
212. hapter3 Connecting XSCF or Server For more detail about changing the All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Console Administration menu operation In the beginning set up Console Administration in XSCF Administration menu of the Machine Administration Menu Examples XSCF Administration 1 Network Configuration 2 User Account Administration 3 Console Administration 4 XSCF Web Administration 5 SNMP Administration 6 Mail Administration q Quit b Back to previous menu t Go to topmenu h Help Select 1 6 q b t h 3 Select Standard Console Choose Select Standard Console in Console Administration menu by number Examples Console Administration 1 Show Current Configuration 2 Select Standard Console 3 Access Control of Read only Console 4 Access Control of XSCF remote control 5 Auto disconnect Administration of XSCF remote control q Quit b Back to previous menu t Go to topmenu h Help Select 1 5 q b t h 2 Next Select Standard Console Current Standard Console Serial port 1 Serial port 2 LAN port q Quit b Back to previous menu t Go to topmenu h Help Select standard console 1 2 q b t h 2 Return Warning If the XSCF Basic Network Configuration is improper Standard Console can not be used at all any more Are you sure y n y Return Setting has completed Hit return key Access Control of Read only Co
213. he DDC A status and 1 8 V voltage value ddcbn n 0 Displays the DDC B status and 2 5 V voltage value inlet Displays the environment information status and inlet temperature power control Displays whether the scheduled power control APCS is enabled and the time that is set net status The net status command is used to view the SCF LAN network status For example it can be used to display the connection state Ethernet data transfer rate and Number of Send Receive packet The following is an example of command execution SCF gt net status a SCF LAN Network Status Connection gt online Speed 100Mbps half duplex Send Packets 2818 Receive Packets gt 23983 6 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 3 Server Status and Control Commands Receive Error Packets 0 Overruns 2g SCF gt nodeled led check all mode on blink off status The nodeled command is used to display the status of each LED on the front and back panel of the server In addition you can make CHECK LED turn on or blink in order to locate the target system After found the location you can free the state of CHECK LED by this command When no option is specified the command shows the status of all LEDs POWER LED ONLINE LED CHECK LED and SCF Ready LED In the addition as described above this command can be used to locate the target system For example when more than one same
214. he SB Or Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF Message PSU n PWOK error Explanation An output voltage error was detected Replacement part number FF FF Action Check the PSU Contact the system administrator or a FE Error level report level error detection source Notice 3 XSCF 4201810n Message PSU n ACFAIL recovered When the input power source is the AC Type PSU n input failure recovered When the input power source is the DC Type Explanation Power was restored Replacement part number 41 PSU 0 2 Action Check the installation environment Contact the system administrator or a FE Error level report level error detection source Notice 3 or 0 XSCF B 45 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4201840n Message PSU n mounted Explanation The PSU unit has been installed Replacement part number 41 PSU 0 2 Action Check the PSU Contact the system administrator or a FE Error level report level error detection source Notice 3 XSCF 42040100 Message AC Power Down When the input power source is the AC Type Power Down When the input power source is the DC Type Explanation A power outage occurred Replacement part number FF FF Action Check the installation environment Contact the system administrator or a FE Error level report level error detection source Notice 3 or 0 XSCF
215. hich locating fault and part number can be specified among parts that XSCF observes in server Server Trap issued XSCF SNMP agent function started Server ee Manager Faulty part replaced Figure 7 2 Conditions for issuing a trap Next 7 4 How to Set up the XSCF SNMP Agent Function 7 4 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 7 4 How to Set up the XSCF SNMP Agent Function 7 4 How to Set up the XSCF SNMP Agent Function This section describes how to set up the XSCF SNMP agent function The process of setting up is described below Each setting is made from the Machine Administration Menu or the scfsnmp 1M command of the Machine Administration function For information about the settings see Chapter2 Setting Up XSCF The command is at ESF2 5 1 or later For detail about the command see the Machine Administration Guide for the ESF Step 1 Make sure that the XSCF SNMP agent function is disabled Ifthe function is enabled disable it Note Be careful when disabling an enabled SNMP agent function since all MIB information except the configuration information specified by Step 2 will be initialized Step 2 Make the necessary settings for the XCSF SNMP agent function XSCF manager Server name Server location Community information 1 or community information 2 Note For the community information either 1 or 2 or both 1 and 2 can be specifi
216. hird edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition Preface In About model name model name PRIMEPOWER250 Rackmount Type 4U and Mnemonic 250 R4 are added viii All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 In Caution a description is added that we support Name server menu Chapter 1 Overview of XSCF In Types of Connection to XSCF and XSCF User Interfaces descriptions of SSH are added Chapter 2 Setting Up XSCF Sections of REMCS Environment Setting via XSCF and SSH Administration are added In XSCF Setup Flow descriptions of REMCS and SSH are added In Network Configuration descriptions of Name server are added In Table 2 3 XSCF Console Administration descriptions about SSH are added And in Read only console the connection number of telnet port is changed to 3 from 2 In Mail Administration descriptions of host name specification and POP authentication are added Chapter 3 Connecting XSCF or Server In Connecting Terminals to XSCF and Types of XSCF Connection descriptions of connecting to XSCF using SSH are added In Table3 1 Connected terminal types descriptions about SSH and SSH port numbers are added In Read only port the number 8013 of telnet port is added The port num
217. ied In addition you can enable or disable the POP authentication at the same time When you enable the POP authentication specify the host name or IP address of the POP authentication server user ID password the POP waiting time Mail destination Specify the address of a system administrator This setting cannot be address setting to whom mail reports are to be delivered omitted Specify multiple addresses by separating them No default setting has with a comma The total number of been specified characters cannot exceed 255 Note A mail address is 64 characters or less 64 characters or less Eight addresses or less can be specified Check the setting of your cell phone if you receive the email by the cell phone which sets the address restrictions From header Specify the mail address to be coded in the This setting cannot be setting From header omitted Use up to 47 ASCII characters Example This address will be used as destination of mail roo example com delivery error notification when SMTP server Note detects the error In case of mail delivery error such as SMTP server cannot find out the destination address of mail this delivery failure will be informed by mail And destination of this delivery failure report will be the address specified in From field Therefore specify address which surely exists and can receive mail Do NOT specify XSCF because XSCF can s
218. ifying the URL For the URL specify the IP address or host name assigned to XSCF with root directory Example URL https 192 168 111 111 The IP address of XSCF is input by number Alternatively https XSCF host name Note This is not a host name of Solaris OS Note When the communication begins a browser might request the confirmation of the certificate Please you must confirm the content and accept the certificate at that time 5 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 5 How to Use the XSCF Web Function Caution at the connection If a lot of data is made to output to the console while using the SSH function You may be unable to connect with the XSCF Web function Next 5 3 Logging In to or Out from XSCF 5 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 5 3 Logging In to or Out from XSCF 5 3 Logging In to or Out from XSCF Logging in to XSCF To connect to the XSCF Web function pages log in to the XSCF top page If login is successful the index page is displayed If login fails a message indicating that login failed is displayed When failure of the log in satisfy the following condition the failure is reported by mail to the system administrator a XSCF users with the same account attempt to access any XSCF Web pages and five or more attempts failed within 3minutes due to authentication failure To use the mail report function register a destina
219. informed by TRAP 2 You can monitor the server status power on off mode switching and reset operations as MIB information 3 Changes in server status and configuration changes are informed by TRAP For information about how and when to log events see the following chapters Referencing logs with XSCF shells Chapter 3 Connecting XSCF or Server Chapter6 How to Use the XSCF Command Shell and Appendix B XSCF Log Information XSCF Web function Chapter4 How to Use the Remote Panels and Chapter5 How to Use the XSCF Web Function MIBlist Appendix C XSCF MIB Each XSCF function needs set up in prior to its start of using See Chapter2 Setting Up XSCF Next 1 5 Time synchronization All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter1 Overview of XSCF 1 5 Time synchronization XSCF uses the same clock hardware as OS Therefore the same time as OS is displayed on the screen in XSCF shell terminal Standard console and the XSCF Web function However when you rewind the clock of OS this will interfere the logging mechanism of following logs The order of logged events might be different from original order or a part of events could even be disappear when you look the following logs on Machine Administration function error logs power logs event logs access logs Next Chapter2 Setting Up XSCF All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting
220. inistrator or a FE Error level report level error detection source Alarm 3 XSCF C3160400 Message PANEL serial number is 0 Explanation The PANEL serial number was all Os Replacement part number 02 PANEL 00 Action Replace the panel Or for models 250 R4 250 P 450 R 450 Q Replace the O back panel Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C3170000 Message Unsupported SB Revision XXXXXXXXXXXX XXXXX Explanation An SB revision with an unsupported is installed Replacement part number 01 SB 00 Action Upgrade appropriate firmware Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CD000600 Message Unknown SCF FMEM ID ID xx TYPE xx Explanation An SCF FMEM with an unsupported ID type is installed Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE01000n Message CPU n JTAG IR setting error Explanation A JIR setting error was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 12 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 CE02000n Message CPU n
221. inistrator or a FE Error level report level error detection source Notice 0 XSCF 6101190n Message Mail name server invalid Explanation Name Resolution of SMTP server failed The Name server was not specified Replacement part number FF FF Action Specify ythe Name server Error level report level error detection source Notice 0 XSCF 6101210n Message Mail setting of SMTP server n failed Explanation The setting failure of SMTP server n was detected Replacement part number FF FF Action Recheck the SMTP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101220n Message Mail setting of SMTP server n failed Explanation The setting failure of SMTP server n was detected Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101310n Message Mail illegal MAIL REPORT parameter specified Explanation Illegal the SMTP server name Destination address Sender address or XSCF host name was specified Replacement part number FF FF Action Recheck the SMTP server name Destination address Sender address and XSCF host name Error level report level error d
222. inistrators Organization This manual consists of the following chapters Overview Setting up XSCF Connecting XSCF or Server How to use the remote panels How to use the XSCF Web function How to use the XSCF command shell XSCF SNMP agent function XSCF mail function XSCF REMCS Agent Function XSCF firmware and dump Warning And Information Messages XSCF Log Information XSCF MIB Troubleshooting Glossary Related Manuals Refer to the following manuals as necessary PRIMEPOWER250 450_ User s Manual Machine Administration Guide Enhanced Support Facility User s Guide REMCS Agent Operator s Guide About Registered Trademarks Sun Sun Microsystems the Sun logo Solaris TM Operating System Solaris OS hereafter and all other Solaris OS related trademarks and logos are trademarks or registered trademarks of Sun Microsystems Inc in the United States and or other countries and are used under license Microsoft is a registered trademark of Microsoft Corporation in the United States and or other countries Netscape and Netscape Navigator are trademarks or registered trademarks of Netscape Communications Corporation in the United States and or other countries Other company and product names are trademarks or registered trademarks of their All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 respective owners Acknowledgement The TCP IP based communication functions of the LAN communicati
223. ion An ID code error was detected Replacement part number 01 SB 00 Action For models 250 R4 250 R 250 P 450 R Replace the SB For model 450 Q Replace the PCI board if U2P 0 s error Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE07100n Message Correct error count over flow offline desired Explanation The CPU is degraded because too many ECC correctable errors are detected Replacement part number 11 CPU 0 3 Action Replace the CPU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF CE080000 i Message SYSTEM CONTROL BUS fatal timeout SC Register Explanation SYSTEM CONTROL BUS timeout error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE09000n Message SYSTEM CONTROL BUS fatal timeout XB n Register Explanation SYSTEM CONTROL BUS timeout error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF CE0A0000 Message SYSTEM CONTROL BUS fatal timeout SC History Explanation SYSTEM CONTROL BUS timeout error was detected Replacement part number 01 SB 00 Action Replace the SB Contact th
224. ion failure event and testing See the event logs list in Appendix B XSCF Log Information to check if the expected report is in the error log or if the report is an event that is reported in the event log Select Show Current Configuration in Mail administration of the Machine Administraion Menu and check whether to have completed the Mail report from XSCF normally If the e mail is not received the mail is sent to the destination for undelivered mail or the error logs is recorded so check them Check whether there is the address restrictions if you receive the email by the cell phone Could not access the top page of the XSCF Web function Check whether the settings for the XSCF Web function have been enabled Check whether the correct URL was input For example s of https is not added Check whether an allowed IP address was specified Check whether SSL and TLS are enabling in the browser settings D 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 D 4 Could not display the login screen of the XSCF Web function f pressing the login button on the top page of the XSCF Web function fails to display the login screen JavaScript may be disabled in the browser settings Enable JavaScript and log in again When the creating of Pop up window is prohibited in the browser settings XSCF Web function fails to display the login screen Enable it and log in again Could not log in to XSCF Web func
225. is down abnormality can be detected The Machine administration function is usually communicating with the REMCS center If the Machne administration function is downed XSCF communicates with the center instead of it As a result errors can be detected more completely and early and a stronger support can be achieved The following is the supporting REMCS agent function of XSCF Table 9 1 Supporting Differences from the Machine Administration function in REMCS Functions of REMCS Agent Machine XSCF administration Registration necessary unnecessary Remote Notification Failure information support support Periodical connection support support Investigation information collection support not support Reception of firmware support not support Next 9 3 Types of REMCS Center Connection All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 9 3 Types of REMCS Center Connection 9 3 Types of REMCS Center Connection The connection type between customer machine and REMCS Center has five types as follows When REMCS service is used Internet Connection In this type of connection the customer machine will be connected to REMCS Center via Internet directly SMTP server is used to send to the REMCS Center And HTTP server is used to receive from the REMCS Center XSCF doesn t use HTTP server REMCS Machine Center Administa Figure 9 2 REMCS report of internet connection Internet C
226. is manual without permission This manual is subject to change without prior notice Electrical form of this manual is installed under following path The revised edition for this manual can be referred to from the following path on the Hardware Control Program CD Path PWPLO MANUAL Hardware Control Program HCP HCP is a control program of hardware that configures a computing system When you face different description written on the online manual from what written on paper manual please follow the online manual The MIB new file can be refferred to from the following path in the HCP CD PWPLO MIB All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Summary of Changes in Eighth Edition The current eighth edition of this manual differs from previous edition principally by containing the addition of descriptions about the XSCF Administration on the command line The eighth edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition Chapter 2 Setting Up XSCF In XSCF Setup Flow a description of the start up of the Machine Administration Menu is added In Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration and Mail Administration descriptions of the setting on the command line of the Machine Administration function are added For these command ad
227. k to previous menu t Go to topmenu h Help Select 1 3 u q b t h 2 Next SNMP Trap Notification 1 Enable 2 Disable q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 u q b t h 1 Next Administration of Community public 1 SNMP Manager Address 192 168 10 123 2 SNMP Trap Notification enable u Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 u q b t h u Return Are you sure y n y Return Setting has completed Hit return key Please follow the instructions from menu in order to complete administration of community public Then you can add second community with using Register Community menu All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 23 Chapter 2 Setting Up XSCF Examples Register Community 1 public a Add New Community q Quit b Back to previous menu t Go to topmenu h Help Select 1 q b t h a Configure second community private as well as the above mentioned Delete Community Select Delete Community in SNMP Administration menu The example of executing the menu of Delete Community as follows Delete Community 1 public 2 private q Quit b Back to previous menu t Go to topmenu h Help Select community 1 2 q b t h 1 Next Delete Community 1 private a Add New Community q Quit b Back to previous menu t Go to topmenu h Help Are you sure y n y Return A co
228. l 250 R Replace the SB For models 250 R4 250 P 450 R 450 Q Replace the SB if fan from 0 to 3 is specified For model 450 Q Replace the PCI board if fan from 4 to 7 is specified Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C30E020n Message FAN n alarm xxxrpm Explanation An abnormal fan speed fan configuration remains redundant was detected Replacement part number 31 FAN 0 7 Action Replace the fan Or Do the action of the above FAN CONTROLLER n Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C30E040n Message FAN n not mounted Explanation A fan was not installed fan configuration remains redundant Replacement part number 31 FAN 0 7 Action Install the missing FAN Or Do the action of the above FAN CONTROLLER n Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 33 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C30F0000 Message PCI MOUNT SENSOR O0 access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 models 250 R4 250 P 450 R 450 Q 05 PCI RISER model 250 R Action For models 250 R4 250 P 450 R 450 Q Replace the SB For model 250 R Repalce the PCI RISER Or Replace the SB Contact the system administrator or
229. lanation A compare error was detected in SCF SDRAM Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0803100 Message SCF SDRAM uncorrectable error Explanation An ECC UE was detected in SCF SDRAM Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0803200 Message SCF SDRAM correctable error Explanation An ECC CE was detected in SCF SDRAM Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0804000 Message SCFC parity error Explanation A parity error was detected in the SCFC Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0804100 Message SCFC parity test error Explanation A parity detection function error was detected in the SCFC Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0805000 Message XSCF current bank checksum error Explanation The checksum for the current bank in SCF FMEM is defferent from one which is stored before swtiching of bank Replacement p
230. level error detection source Notice 0 XSCF 6111120n Message REMCS Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111130n Message REMCS Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed SMTP server n was not found Replacement part number FF FF Action Recheck the SMTP server Error level report level error detection source Notice 0 XSCF 6111140n Message REMCS communication to name server timeout Explanation Name Resolution of SMTP server failed The timeout occurred by the Name server Replacement part number FF FF Action Recheck the SMTP server or the Name server Error level report level error detection source Notice 0 XSCF 6111150n Message REMCS Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111160n Message REMCS Name Resolution of
231. low x02 AUPS alarm occurred 06 Thermal Temperature error el Detailed code xVVqq0000 Explanation A temperature error occurred VV indicates the detailed event and qq indicates the sensor ID The definition of VV is as follows x02 A high ambient temperature warning occurred x04 A low ambient temperature warning occurred x06 Ahigh CPU temperature warning occurred x07 Ahigh CPU temperature alarm occurred x12 Recovery from he high ambient temperature warning or low ambient temperature warning was successful x16 Recovery from the CPU temperature warning was successful x20 Fan speed increased x21 Fan speed decreased B 71 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 07 PDOWN Power outage power recovery el Detailed code xVVqq0000 Explanation A power outage occurred or power was restored VV indicates the detailed event and qq indicates the detailed information on the source The definition of VV is as follows x01 A power outage occurred x02 Power was restored 08 Nodeself Node self error el Detailed code x00VVppss Explanation A node specific error occurred VV indicates the detailed event pp indicates the first item of detailed information and ss indicates the second item of detailed information The definition of VV is as follows x90 A status check timeout occurred x91
232. m 3 Warnig 1 Warnig 2 Warnig 3 Warnig 4 Notice 1 Notice 2 Notice 3 Notice 4 Table B 1 5 Warning level errors 1 Error code Message and explanation 4201010n Message PSU n ACFAIL When the input power source is the AC Type PSU n input failure When the input power source is the DC Type Explanation Input power source failure power supply remains redundant was detected Replacement part number 41 PSU 0 2 Action Check the installation environment Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and lO back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 4201040n Message PSU n mount error Explanation A PSU is not installed power supply remains redundant Replacement part number FF FF Action Check the PSU Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 5080000n Message Parts Status Reset Failure Explanation In Machine Administration Menu the status of abnormal PSU was reset Replacement part number 41 PSU 0 2 Action Check the installation environment Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and lO back panel Or Replace the SB Or Contact the system administrator or a FE Error level report level error detec
233. m has two kinds of abnormality notification mechanism by mail originally One is managed by machine administration which is a part of ESF the other is achieved by XSCF This section describes the features of both functions Features of mail function for machine administration Notification by e mail of peripheral unit faults Since the function sends e mail for faults that are detected at not only a part in server but also at peripheral units connected to the server wide range of system problems can be informed Reporting of detailed fault information with an attached file Since the function attaches the detailed information of a fault part to the mail the cause of the fault can be determined more clearly Features of the XSCF mail function Notification by e mail of each case of a parts fault on the server Even though a system failure or serious failure that prevents normal operation of OS occurs the function is still able to send e mail POP authentication facility at e mail sendings is possible To prevent illegal Mail Sending POP Authentication POP before SMTP can be done before Mail Sending is accepted with SMTP server Note Single problem may cause two separate e mail messages one from the machine administration and one from XSCF For more definite and complete detection of errors Enabling the mail notification of both functions machine administration and XSCF is recommended 8 2 All Rights Reserved Copyright
234. mmunity was deleted Hit return key Setting on the command line The SNMP Administration can also be set by using the scfsnmp 1M command of the Machine Administration function Use the scfstat 1M command to display the configuration information When you set up the SNMP Administration on the command line please perform the scfreset 1M command to reflect the setting For details of these three commands of the Machine Administration function see the command reference in the Machine Administration Guide for the ESF The commands are at ESF2 5 1 or later Information The layout and the content of the menu show a sample It might be changed because of the function improvement 2 24 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings 2 2 6 Mail Administration Specify the XSCF Mail Administration This is optional The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration RREMCS Administration SSH Administration Table 2 6 XSCF Mail Administration Item Description Remarks Mailer setting Specify whether to enable or disable the The mailer is disabled by mailer default Server setting Specify the host name or IP address of the No default setting has SMTP server been specified Up to two SMTP servers can be specif
235. mp of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF B 58 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 620004FF Message REMCS Agent stopped by REMCS library Explanation REMCS library failure occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 620005FF Message REMCS Agent stopped by REMCS library Explanation REMCS library failure occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 620100FF Message REMCS Agent stopped by firmware Explanation REMCS Agent stopped by firmware failure Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 81110000 Message This is a TEST log Explanation A test Warning level is executed in Machine Administration function Replacement part number FE test FF Action None Error level report level error detection source Notice 3 XSCF 86110000 Message This is a TEST log Explanation A test Warning level is executed in XSCF shell function Replacement part number FE test FF Action None
236. n menu Examples Appearance of Web Page Current Appearance Text only 1 Text only 2 Text and Images q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 2 Next Appearance of Web Page Current Appearance Text and Images 1 Text only 2 Text and Images q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 2 Return Are you sure y n y Return Setting has completed Hit return key Access Control Next set up Access Control in XSCF Web Administration menu Examples Access Control a Add an Access allowed Host u Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select a u q b t h a Return Enter the address of host 1 To clear information just type in return key Input 192 168 10 1 2 18 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Next Access Control 1 Host 1 192 168 10 1 a Add an Access allowed Host u Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select a u q b t h u Return Are you sure y n y Return Update was completed Hit return key When you press the return key then it goes back to Add an Access allowed Host menu To specify additional host repeat same procedure You can change the configuration of access allowed host as follows Access Control 1 Host1 192 168 10 1 2 Host2 192 1
237. n executed during power off a reset or shutdown The required authority for this command is root level For information about an OS dump see the Machine Administration Guide for the ESF The following is an example of command execution SCF gt request SCF gt Note request command causes the system panic to collect the memory dump Purpose of this command is only for maintenance such as to investigate hangup of system Therefore please do NOT execute this command except when it is surely necessary WARNING File system could be damaged by executing this command during OS is working power off The power off command is used to power off the server This command is ignored if used when server power is off Note that this command does not affect the power supplying to XSCF The required authority for this command is root level Note Please use this command only when you cannot stop your system in normal procedure due to 6 14 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 3 Server Status and Control Commands any software or hardware trouble Do NOT use this command on normal working system For normal working system please use shutdown command WARNING File system could be damaged by executing this command during OS is working power on The power on command is used to power on the server This command is ignored if used when the server power is on Note that the command does not affect the XSCF po
238. n q y Return Enter new data smtp server Return SMTP Server1 name smtp server User authentication of SMTP Server1 POP before SMTP Do you want to change the settings y n q y Return Authentication method for SMTP Server1 0 none 1 POP before SMTP Enter the authentication method 0 1 1 Return POP Server name for SMTP Server1 smtp server Do you want to change the settings y n q y Return Enter new data smtp server Return POP UserID for SMTP Server popy Do you want to change the settings y n q y Return Enter new data popy Return POP Password for SMTP Server1 SERARETER Do you want to change the settings y n q y Return New password XXXXXXXXXX Return Enter the new password again New password xxxxxxXXxxXx Return SMTP Server2 name Do you want to change the settings y n q n l 2 32 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Next Write Environment Setting to XSCF REMCS via XSCF Enabled SMTP Server1 name smtp server User authentication of SMTP Server1 POP before SMTP POP Server name for SMTP Server1 smtp server POP UserID for SMTP Server1 popy POP Password for SMTP Server1 E SMTP Server2 name An asterisk indicates an indispensable item 1 Write Environment Setting to XSCF 2 Update Select one 1 2 q 1 Return Environment Setting was written to XSCF Now sending test mail to REMCS
239. n you terminate the connection you will not be able to access XSCF for 20 minutes The maximum timeout setting is 255 minutes Next 5 4 XSCF Web Function Pages 5 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 5 How to Use the XSCF Web Function 5 4 XSCF Web Function Pages This section describes the organization of the XSCF Web function pages For information about the operations available on these pages see Chapter4 How to Use the Remote Panel and Chapter6 How to Use the XSCF Command Shell Operations for status display and control Remote panel Display of the status of the LEDs on the panel Display of the status of the mode switch Message on the panel referred to as a remote panel message Log display Hardware error log power log and remote panel message history can be checked Switch operations except mode switch The server can be turned on or off or reset and output of an OS dump can be requested To be able to perform switch operations set an appropriate mode and log in to XSCF with root level authority Help Display of server status Status display by unit Help Logs Error log Power log Remote panel message history Other features Changing of the password Allows you to change the password assigned to an XSCF account used to log in to XSCF For the restrictions on the password see Chapter2 Setting Up XSCF Display of acc
240. nagement Protocol SNMP agent function This section provides an overview of the SNMP agent function The following figure shows an example of network management environment based on SNMP Server Server Server Printer HIB Trap Router renes Issued Manager Server Server Printer Figure 7 1 Example of network management environment SNMP is a protocol for network management The SNMP manager enables integrated management of the operating status and fault status of the terminals in the network The SNMP agents return management information referred to as MIB Management Information Base in response to the SNMP manager s request For specific kinds of information the agents can use the TRAP function to send asynchronous notifications to the SNMP manager Note Several kinds of SNMP manager may be available For example Web SysAdmin WSA software is available from us Next 7 2 About MIB 7 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 7 2 About MIB 7 2 About MIB The SNMP agent function has management information referred to as MIB Management Information Base and returns it in response to the SNMP manager s request Standard MIB XSCF supports MIB II the Internet standard which manages several issues like follows Basic information about the SCF LAN including the administrator s name Information about the communication processing on the SCF LAN
241. nagement server SMTP server is necessary Therefore the setting of SMTP server becomes indispensable as for the XSCF function For more information about Management Server Connection see the REMCS Agent Operator s Guide Machine Management Administratiq Sever SMTP Machine Administratic Figure 9 6 REMCS report of Management Server connection Next 9 4 How to Set up the XSCF REMCS Agent Function All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 9 XSCF REMCS Agent Function 9 4 9 8 How to Set up the XSCF REMCS Agent Function This section explains how to setting up the XSCF REMCS agent The required steps are explained below Each setting is made from the Machine Administration Menu For details of the settings Step 1 Setting up XSCF network environment Set the XSCF network environment on the Machine Administration Menu For information of Network Configuration see Chapter2 Setting Up XSCF Step 2 Setting up REMCS agent environment Set the REMCS agent environment on the Machine Administration Menu And do the Registration Setting up REMCS environment and Connection check For informations of the settings see REMCS Agent Operator s Guide Step3 Setting up XSCF REMCS notification In Setting up REMCS agent on Machine Administration Menu do the setting of REMCS Environment Setting via XSCF For information of the setting see Chapter2 Setting Up XSCF S
242. nation A SRAM data error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 04000031 Message SC Register error SC Explanation A SC register error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 05000032 Message SCF check error SCF Explanation A XSCF reset timeout was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 05010032 Message SCF check error SCF Explanation A XSCF status error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 10000030 Message DTAG error DTAG Explanation A DTAG error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 10010030 Message DTAG error DTAG Explanation A DTAG error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 10100030 Message DTAG Init error DTAG Explanation At the initialization of DTAG an error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection
243. nation address setting From header setting Next set the mail address and server Examples 2 26 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Enable Mail Report and Setup 1 To 2 From 3 SMTP Server1 4 SMTP Server2 u Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 1 Return The mail address set by the Hardware Monitoring Information menu cannot be used by XSCF You cannot copy it Enter Destination Mail Address user example com Next Enable Mail Report and setup 1 To user example com 2 From 3 SMTP server 1 4 SMTP server 2 u Setup execution q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 2 Enter Mail Address assigned to From field admin example com Next Enable Mail Report and setup 1 To user example com 2 From admin example com 3 SMTP server 1 4 SMTP server 2 u Setup execution q Quit b Back to previous menu t Go to topmenu h Help Select 1 4 u q b t h 3 Return Do you really want to enable POP before SMTP y n y Return Enter the Host Name or Address of SMTP server 1 To clear information just type in return key Input smtp server Return Enter the Host Name or Address of POP server To discontinue setting of SMTP server just type in return key Input smtp server Return Enter the User Name of
244. nd of Machine Administration function Check whether the entered IP address and port number are different from the settings Check whether someone have already logged in to XSCF by using telnet port If necessary please use the console you can access from PC which is directly connected to XSCF by serial port tty a Then login to the XSCF Shell and check the the status of SCF LAN settings with lan conifg command Could not connect using SSH to XSCF via the SCF LAN Check whether the SCF LAN settings by the Machine Administration Menu have been enabled Check whether the SSH settings have been enabled by a command of Machine Administration function Check whether the entered IP address and port number are different from the settings Check whether someone have already logged in to XSCF by using SSH port If necessary please use the console you can access from PC which is directly connected All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 to XSCF by serial port tty a Then login to the XSCF Shell and check the the status of SCF LAN settings with lan conifg command Check whether the host key is set up correctly In addition if you replace a system board the host key is initialized by the pre configured key which XSCF has Check whether the cliant soft is set up correctly Output on Standard console OS console connected to the LAN suddenly stopped The reason could be the command of XSCF which change
245. ne ee an aimecawer lone ro Displays information about the server such as SS i power on power off and reset information show event logs r oO Displays the server event log show console logs o a a information which is output to the Displays information about accesses to the XSCF Web show access logs r oO f unction pages thermal history r oO Displays the temperature history of the server show ipl logs r oO Displays information about server IPL messages show panic logs r oO Displays the logging information recorded for a panic date r oO Displays the current date and time rci config r oO Displays the RCI configuration information Displays the system configuration information for the a ie server All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 1 Overview of XSCF Command Shell lan config r oO Displays information about the XSCF LAN configuration send break r The break signal is issued to the server exit r Oo Exits the current XSCF shell help r o Displays a list of available XSCF shell commands Displays a login keyword that can move to the XSCF shell terminal from the Standard console Changes a login keyword that can move to the XSCF show shell command r o Ss d shell terminal from the Standard console logtest r Generate a test error and get the test logs version r oO Displays the firmware versions of the XSCF and OBP r root o
246. nel Operating Panel ingi Same function Three LED stat dicators SS SATSAS Note that the front remote panel POWER LED ONLINE LED refreshes the XSCF Web browser page CHECK LED at intervals of about 10 seconds If necessary refresh it manually Pressing of switch may be igonored ee depending on the Three butt t Na wipes det aia They do not mode specified by Power switch Front an se ete depend on the 3 mode switch panel PSAE mode switch Refer to User s Request switch Manual for the server for more detail 3 mode switch indicator Indicates the F Indicates the state state of the switch d LOCK mode Givi Themode of the switch and UNLOCK mode eae b the mode can be MAINTENANCE mode switched switched Two LED status indicators Back panel CHECK LED Same function SCF Ready LED Message i Displays No messages are Displays messages window messages displayed Initial A settings Settings enabling XSCF to be used Required Not required Next Chapter5 How to Use the XSCF Web Function All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 9 Chapter 4 How to Use the Remote Panel 4 10 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter5 How to Use the XSCF Web Function This chapter explains how to use the XSCF Web function This chapter has the following contents Contents 5 1 Overview of the XSCF Web Function 5 2 Starting the XSCF
247. ng Mail Destination Address Setting From Header Setting 9 Setup the REMCS environment setting via XSCF Optional but recommended because you can send a mail to REMCS center in case of system down Machine Administration Menu REMCS agent Menu REMCS Environment Setting via XSCF option Enable Disable REMCS via XSCF Server Setting 10 Exit the Machine Administration Menu Then set up the SSH function on the comman line Optional but recommended because you have a high level of security on your console Information Those window images are samples It differs from an actual screen Next 2 2 Specifying the XSCF Settings 2 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF 2 2 Specifying the XSCF Settings This section describes in detail the XSCF settings to be specified The XSCF setting is done by the Machine Administration Menu You must have root privilege to use this menu 2 2 1 Network configuration Specify the network environments of SCF LAN Network configuration must be made The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration REMCS Administration SSH Administration Table 2 1 XSCF Network configuration Item Description Remarks IP Address Specify the IP address A console of the X
248. ng event x20 The RCI receiving event x30 The RCI initial operation x31 The RCI initial configuration x32 The RCI initial reconfiguration x3F The RCI configuration result Appendix C XSCF MIB Object ID and Table of scfMonitor group is added Appendix D Troubleshooting In Aconsole the XSCF shell or a standard console was suddenly disconnected a description of Name server configuration is deleted In Could not log in to XSCF Web function the description is all corrected In Do not know the IP address of XSCF a description of Show current configuration of Basic configration is changed to Network Configuration Glossary The term SCF IMAGE is changed to WEBDATA The term Shadow console is changed to Read only console And the port number 8101 is corrected to 8011 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 The terms of IO BP POWER BD and PSU CAGE are added Summary of Changes in First Edition Revision1 The first edition Revision1 of this manual contains minor clarifications and corrections and also the following significant changes relative to the first edition Preface Acknowledgement about SSL is added Chapter 6 How to Use the XSCF Command Shell Adescription of the setting and view of XSCF shell login keyword is added The command of set shell commana is added Chapter 8 XSCF Mail Function Contents of Susp
249. nged Explanation OBP FMEM was upgraded to a new version Replacement part number FF FF Action Check the version Error level report level error detection source Notice 3 XSCF 431601FF Message SB changed Explanation An SB has been replaced Replacement part number FF FF Action None Error level report level error detection source Notice 3 XSCF 431602FF Message PANEL changed Explanation A panel has been replaced Replacement part number FF FF Action None Error level report level error detection source Notice 3 XSCF B 46 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 ABER Message SB or PANEL changed Explanation A SB or a panel has been replaced Replacement part number FF FF Action Contact a FE Error level report level error detection source Notice 3 XSCF gen GOREP Message Restore error from SCF FMEM to PANEL EEPROM Explanation The restoration from FMEM to PANEL failed Replacement part number FF FF Action Contact the system administrator or a FE Error level report level error detection source Notice 3 XSCF SSACOTEE Message Backup error from PANEL EEPROM to SCF FMEM Explanation The backup from PANEL to FMEM failed Replacement part number FF FF Action Contact the system administrator or a FE Error level report level error detection source Notice 3 XSCF ayes Message
250. nistrator the setting process is complete If the e mail is not received the mail is sent to the destination for undelivered mail or the error logs is recorded Determine why the mail could not be delivered and make the necessary modifications then restart from step 1 For the Machine Administration Menu see the Machine Administration Guide of the ESF The command is at ESF2 5 1 or later For detail about the command see the Machine Administration Guide for the ESF Next 8 5 Contents of Parts Fault Notification All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 8 5 8 5 Contents of Parts Fault Notification Contents of Parts Fault Notification This section explains the contents of e mail that is sent when a faulty part is detected The following shows the contents of an e mail notification Date Mon 02 Jun 2003 14 03 16 0900 From XSCF lt roolgphost name domaia name oo amp i gt To mail address smtp domain name com 2 Subject host name XSCF A PANEL SCF Detected failure on the PANEL X Mailer COS X m H versio m 0 MINE Version 1 0 3 6 Content Transfer Encoding 7bit Content Type text plain char set7US ASCII Content Length 215 Jun 02 14 03 16 host gd Figure 8 4 Mail reporting a faulty part The following describes how to read the contents of the mail shown in Figure 8 4 1 Mail address specified for the From designation in the mail settin
251. nsole Next configure the read only OS console port in the telnet ports or SSH ports of SCF LAN by selecting Access Control of Read only Console in Console Administration Examples All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF Access Control of Read only Console Current Configuration disable 1 Enable 2 Disable q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 1 Return Are you sure y n y Return Setting has completed Hit return key Access Control of XSCF remote control Next configure the XSCF Shell port in the telnet ports or SSH ports of SCF LAN by selecting Access Control of XSCF remote console in Console Administration Examples Access Control of XSCF remote control Current Configuration disable 1 Enable 2 Disable q Quit b Back to previous menu t Go to topmenu h Help Select 1 2 q b t h 1 Return Are you sure y n y Return Setting has completed Hit return key Auto disconnect Administration of XSCF remote control Next set up the Automatic logout by choosing Auto disconnect Administration of XSCF remote control in Console Configuration by number Examples Auto disconnect Administration of XSCF remote control Current configuration 10 q Quit b Back to previous menu t Go to topmenu h Help Enter minutes to disconnect inactive user 0 1 255 q b t h 0 Return Auto disconnect will be disabled Are y
252. nsole via LAN port please set the Standard console to the LAN port by the Console Administration of the Machine Administration Menu Note When you send a Break the break signal is issued to the server Connecting to XSCF using SSH via the LAN port The procedure described in this section assumes that the XSCF initial settings described in Chapter2 Setting Up XSCF have been completed For the connections between XSCF and PC workstation with LAN cable see the User s Manual for the server The following is the procedure for connecting to a terminal using SSH via the LAN port 1 Make sure that the LAN cable from the HUB is connected to the SCF LAN port connector on the rear of the server Comfirm the secure connection to the PC or workstation also All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server 2 On the PC or workstation to be used use one of the following procedures Connecting to a terminal dedicated to the XSCF shell 1 To establish a SSH connection activate the SSH cliant and specify the IP address of XSCF and port number 8810 2 Enter the ID and password to start the XSCF shell 3 Make sure that the XSCF shell prompt SCF gt is displayed 4 The XSCF shell can now be used Note You can connect to the XSCF shell even when the power of the system is off Connecting to the Standard console OS console 1 Ifthe server is off turn it on to start the OS
253. ntact the system administrator or a FE W Warning Serious problem but system can keep working The system can continue operation but there is a problem with the configuration Contact a FE N Notice notification The message reports an event such as a change in installation environment This does not mean a problem Report level Shows whether an automatic report is done to the REMCS center when the system detects an error concerned The service contract is separately necessary for a remote control from the REMCS center Only when the service contract is made and ESF is set correctly concerning REMCS an automatic reporting is done There are two report levels 3 There is a serious problem with a part or a system warning has occurred Reporting is done 0 There is no problem and reporting is not done ee The hardware which detects an error There are XSCF POST anon OBP and Machine Administration A list of errors for each error level recorded in the error log is provided below B 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Alarm The following table lists alarm level errors errors that prevent the continuation of system operation and the actions to be taken To view errors by error code use XSCF Error Code Table in Section B 4 Alarm 1 Alarm 2 Alarm 3 Warnig 1 Warnig 2 Warnig 3 Warnig 4 Notice 1 Notice 2 Notice 3 Notice 4 Table B 1 2 Alarm level errors 1 Er
254. nyyyyyy nnyyyyyy nnyyyyyy SPARC Explanation A request was sent from XSCF to SPARC VV indicates the detailed request event The definition of VV is as follows x01 Request to SPARC for shutdown nn indicates the event code yy indicates the Detailed code byte 0 2 Detailed code byte 8 F are ignored x02 Request to SPARC for power off x03 Request to SPARC for log collection x04 Request to SPARC for information in the event log x05 Request to SPARC to collect dump of XSCF memory x06 Request to SPARC for event nn indicates the event code yy indicates the Detailed code byte 0 2 C4 Panel Detailed code x01mm0000 Panel Explanation A panel operation event occurred mm indicates the button operation operation number event The definition of mm is as follows x01 The POWER switch button was pressed in a short operation x02 The RESET switch button was pressed in a short operation x03 The Request switch button was pressed in a short operation x81 The POWER switch button was pressed for a long time _ x83 The Request switch button was pressed for a long time Detailed code x02mm0000 Explanation A panel operation event for the mode switch occurred mm indicates the mode switch operation number The definition of mm is as follows x01 The mode switch was set to maintenance mode x40 The mode switch was set to unlock mode x80 The mode switch was set to lock mode
255. of Authentication Failure Notification 8 6 Contents of Authentication Failure Notification This section explains the contents of the e mail that is sent when authentication fails The following shows the contents of the mail that is sent Date Mon 02 Jun 2003 14 03 16 0900 From XSCF lt rooigghost name domein neme cok gt To mail address smtp domain name com _ 2 Subject host name XSCF TELNET 8010 SCF Notification FAILED LOGIN X Mailer COS X maiiversion 1 0 MINE Version 1 0 3 Content Transfer Encodifg 7bit S Content Type text plain char set US ASCII Content Length 215 Jun 02 14 03 16 host name XSCF Notification FAILED LOGIN Madel Name Fujitsu PRIMEP OWER450 PWOLBS111 System Serial No 123456789 000123 Erqor Parts Detail LOG Failed Login LOGIN scf ON TELNET 8010 FROM 192 168 1 10 Figure 8 5 Mail reporting authentication fails The following describes how to read the contents of the mail shown in Figure 8 5 Circled items 1 to 3 above are the same as in the previous section 4 Network access when the authentication failure occurred The number in parentheses indicates the port number The following table lists the types of network access and the port numbers Table 8 1 Network access types and port numbers Type port number Meaning TELNET 8010 Access from TELNET port 8010 SSH 8810 Access from SSH port 8810 SSH 8811 Acce
256. ommunication But the Detailed code is x20000061 when Panic was executed Detailed code x30000000 OOnnnn0O Explanation The RCI initial operation was executed nnnn is an initial address Detailed code x31000000 nnnnnnnn Explanation The RCI initial configuration was executed nn is Node ID Detailed code x32000000 nnnnnnnn Explanation The RCI initial configuration was executed again nn is Node ID Detailed code x3F0000rr Explanation The RCI configuration result was shown nn is result value Detailed code x80ppsstt Explanation The RCI device is recovered from failure state by retry ppsstt indicates the detailed information C6 Setup Detailed code xVV000000 nnnnnnnn nnnnnnnn Setup Explanation An event related to installation or replacement of hardware occurred related VV indicates the detailed event and nn indicates the serial number after replacement 0 at the SB PANEL disagreement The definition of VV is as follows x01 The SB was replaced with spare part x02 The panel was replaced with spare part x80 The SB PANEL did not match C7 External Detailed code xVVqq0000 Extended Explanation An extended system status report event occurred VV indicates the system status report detailed event and qq indicates the status code The definition of VV is as follows x81 OBP complete was reported x82 Suspend start was reported x83 Suspend
257. on The system control bus detected an access error Replacement part number 11 CPU 0 3 Action Replace the CPU Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C3080000 Message SB FRU access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C309000n Message DDC VID n access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C30A000n Message DUAL FMEM CONTROLLER n access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C30E010n Message FAN CONTROLLER n access error Warning Explanation Lost of fan redundancy caused by access error to system control bus is detected And fans are changed to mode of higher rotation speed Replacement part number 01 SB 00 model 250 R 32 FANJT O 1 FAN 0 3 of model 250 R4 250 P 450 R 450 Q 03 PCI BD 00 FAN 4 7 of model 450 R 450 Q Action For mode
258. on You may have to specify TCP IP port number to your telnet or SSH program You can use either telnet or SSH at the same momemnt Only one user can use these port at the same momemnt Note After login if the XSCF shell has not been accessed for a predetermined time the user is forcibly logged out Standard console OS console telnet 23 OS console enabled for input and output SSH 22 You can use either telnet or SSH at the same Note momemnt Only one user can use these port at the same momemnt When you use the Standard console via LAN port please set the Standard console to the LAN port by the Console Administration of the Machine Administration Menu Read only console telnet 8011 OS console used for display only 8013 You can use either telnet or SSH at the same SSH 8811 momemnt 8812 Two users can use telnet 8011 port And one user Note can use telnet 8013 port the 8011 port Only one user can use SSH in each port at the same 2 connection can be momemnt used is used for only the cluster control software when you use the cluster control software The 8013 port is used for only the remote console port All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 3 Chapter 3 Connecting XSCF or Server When a URI is specified in the browser the XSCF Web SSL 443 function can be used Serial port X
259. on administration functions described in this manual were developed by Fujitsu Ltd according to BSD NETWORKING SOFTWARE RELEASE 1 4 4 BSD Lite 2 and their documentation under license from the University of California at Los Angels UCLA We express our gratitude to the Computer Systems Research Group and Electrical Engineering and Computer Science Department at UCLA Berkeley Note that Fujitsu Ltd holds the copyright on the TCP IP based communication functions for XSCF and any secondary documentation related to them Copyright c 1979 1980 1983 1986 1988 1989 1991 1992 1993 1994 The Regents of the University of California All rights reserved XSCF Web Access was developed with the use of Apache and OpenSSL and mod_ssl We would like to express our gratitude to the Apache Group OpenSSL Project Mr Eric Young and mod_ssl project This product includes software developed by the Apache Group for use in the Apache HTTP server project http www apache org This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit http Awww openssl org This product includes cryptgraphic software written by Eric Young eay cryptsoft com This product includes software developed by Ralf S Engelschall lt rse engelschall com gt for use in the mod_ssl project http www modssl org November 2005 November 2005 Eighth Edition C120 E184 08ENZ2 Important Do not copy the whole or any part of th
260. onLeaf viewDomains f nonLeaf snmpDomain 3 nonLeaf rfc1157Domain 3 1 nonLeaf cltsDomain 3 1 nonLeaf cotsNDomain 3 1 nonLeaf cotsXDomain ssd nonLeaf After correcting the key word view nonLeaf vi ewDoma ins nonLeaf snmpDomain 3 nonLeaf rfc1157Domain_2 3 1 nonLeaf cltsDomain 3 1 nonLeaf cotsNDomain 3 1 nonLeaf cotsXDomain 3 1 nonLeaf All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 7 XSCF SNMP Agent Function 7 5 2 7 8 Installation case to SystemWalker Step 1 Start the application of System Monitor of SystemWalker and click in the following order Tools menu Extend MIB Extend MIB dialog box is displayed Step 2 Click Add button of Extend MIB dialog box Select of Extend MIB file dialog box is displayed Step 3 Select extended MIB file of XSCF in Select of Extend MIB file dialog box Selected extend MIB compilation is begun When the compilation is completed Extend MIB dialog box is displayed Step 4 Click the OK button in Extend MIB dialog box Step 5 Close Extend MIB dialog box Step 6 Start MS command prompt and execute the following command Name of the directory used here must be different from your environment Please specify your using directory C gt Directory of SystemWalker MPWALKER DM MpCNapp MpCNmgr b i n CNSetCnfMg exe f Directory of XSCF M BMpr imepower_xscf cnf
261. only Action Replace the PCI board model 450 Q only Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8313000n Message PSU n FRU access error Explanation An FRU access error on PSU n was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8313010n Message PSU n FRU data error Explanation An FRU data error on PSU n was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8314000n Message SCSI BP n FRU access error Explanation An FRU access error on SCSI BP n was detected Replacement part number 04 SCSI BP 0 1 Action Replace the SCSI BP Or for models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8314010n Message SCSI BP n FRU data error Explanation An FRU data error on SCSI BP n
262. onnection Mail only In this type of connection the customer machine will be connected to REMCS Center via Internet directly However only SMTP server is used to send to the REMCS Center Therefore the firmware reception function is not available REMCS Machine Center Administa Internet Figure 9 3 REMCS report of internet connection Mail only All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 9 XSCF REMCS Agent Function Point to Point ISDN Connection In this type of connection the customer machine will be connected to REMCS Center via ISDN line directly It is necessary to connect both LAN that the Machine Administration function uses and LAN that XSCF uses with the ISDN line ISON line REMCS Machine Center A SMTPIHTTP Figure 9 4 REMCS report of Point to Point ISDN connection Point to Point VPN Connection In this type of connection the customer machine will be connected to REMCS Center via broadband line such as ADSL etc with using VPN router It is necessary to connect both LAN that the Machine Administration function and LAN that XSCF uses with the VPN router Broadband line REMCS Machine Center A SMTPIHTTP Figure 9 5 REMCS report of Point to Point VPN connection 9 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 9 3 Types of REMCS Center Connection Management Server Connection Because XSCF cannot be communicated with the ma
263. onsole standard console or outputs by mail or the SNMP function This appendix has the followings Contents A 1 Message Types A 2 A 2 Messages in Each Function A 8 A 1 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 A 1 Message Types When an error occurs in the system XSCF takes various action against this error such as displays a warning or notification message on the OS console send TRAP to a SNMP manager send a mail report to the administrator and take a log In addition when you power on off or reset the sysytem XSCF displays an information message on the OS console This section describes the messages that are most likely to be seen by the user when a server error or the status of the server is reported The following are the typical types of messages System messages Error messages Other information messages System messages A system message displays information in simple form when a server error or the status of the server is reported You can locate the point of problem by displayed system message on the console The following table lists the system messages and their meaning Table A 1 System messages System message Meaning An error occurred in the Detected hardware error platform dependent module FRU An error occurred on the Detected failure on the System Board system board SB Detected failure on the fan An error occurred in the fan An er
264. or the ESF The commands are at ESF2 5 1 or later Information The layout and the content of the menu show a sample It might be changed because of the function improvement 2 11 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF 2 2 3 2 12 Console Administration Specify the console of XSCF Console Administration must be made The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web When you use the SSH function select the SCF LAN port in this settings and set up the SSH settings on the Machine Administration function s command For the SSH settings see the SSH Administration Administration SNMP Administration Mail Administration REMCS Administration SSH Administration Table 2 3 XSCF Console Administration Item Description Remarks Select Standard Select whether to use a standard console via The default is the serial Console the serial port tty a or the SCF LAN port port If you set the SCF LAN port the Standard console port which read write OS console in the XSCF telent ports or SSH ports is enabled automatically Access Control of Read only Console Specify whether to enable or disable the Read only console port in the XSCF telnet ports or SSH ports When you use the SSH function enable this settings and set up the SSH settings
265. or the device occurred The definition of VV is as follows x01 The status of the power supply unit changed x02 The status of the fan changed x03 The status of the temperature sensor changed x04 The status of the battery for memory backup changed x05 The status of the UPS changed x06 The status of the humidity sensor changed x07 The status of the HDD changed 60 Sysinfo System status report Detailed code xVV000000 Explanation The system status was reported The definition of VV is as follows x00 Power off x01 Panic happened x02 Startup after a shutdown x08 Initialization phase x09 Boot processing _x0a The system is in the running state 61 Panic Panic report Detailed code x00000000 Explanation Panic happened B 72 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 62 Config Unit configuration change Detailed code x01mmaqss yyyyyyyy yyyyyyyy YYYYYYYY YYYYYYYY Explanation A part was added mm indicates the part name number qq the part number ss the old unit status y s the the serial number after replacement without FAN or PSU The definition of mm is as follows x02 Fan x03 PSU x05 Panel x06 SB x10 CPU x11 Slot x12 PCI BD x13 SCSI BD The definition of ss is as follows The ss is zero when mm is FAN or PSU The ss the old unit s
266. ore you can view the log information of latest one day The information can be used for investigating the server environment for a system error or other problem The following shows the format of a line in the temperature history TIME Temperature Celsius minutely 10 or 60 TIME Time that the temperature was measured Temperature Indicates the temperature Celsius every 10 minutes or 1 hour For a graphic representation the interval is every 30 minutes The following are examples of command execution SCF gt thermal history Thermal History Celsius GMT__ _INLET__CPUO_CPU1_CPU2_CPU3__SBO__SB1 01 39 027 OFF DS 028 02 39 027 OFF 039 028 6 20 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 4 XSCF Log View Command 03 39 027 30 033 027 04 39 027 O32 035 027 05 39 027 033 030 W27 06 39 027 035 037 Q27 07 39 OFF 036 037 027 08 39 027 QF 038 028 09 39 027 7 see 039 028 10 39 Of OF m US Or 11 39 027 035 030 026 SCF gt SCF gt thermal history cpud Thermal History cpu0 Celsius GMT_ 00 10 20 30 40 50 MIN 01 10 OFF OFF OFF OFF OFF 02 00 OFF OFF 029 030 030 030 03 00 030 030 031 031 031 031 04 00 032 032 032 032 033 033 05 00 033 033 034 034 034 035 06 00 035 035 035 035 036 036 07 00 036 036 036 036 036 036 08
267. ou sure y n y Return Setting has completed Hit return key Setting on the command line The Console Administration can also be set by using the scfconsole 1M command of the Machine Administration function Use the scfstat 1M command to display the configuration information When you set up the Console Administration on the command line please perform the scfreset 1M command to reflect the setting For details of these three commands of the Machine Administration function see the command reference in the Machine Administration Guide for the ESF The commands are at ESF2 5 1 or later 2 14 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Information The layout and the content of the menu show a sample It might be changed because of the function improvement All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF 2 2 4 XSCF Web Administration Specify the XSCF Web Administration for the XSCF Web function and specify whether access to XSCF using the http protocol is enabled or disabled The XSCF Web Administration are optional The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration REMCS Administration SSH Administration Table 2 4 XSCF Web Administration Item Descrip
268. ower environment control interface RCI and other power environment control interfaces including power control status monitoring and disaster prevention panel control FAN JT A fan board Fatal The state resulting from the occurrence of a fatal error FMEM An abbreviation of flash memory FMEM is a nonvolatile PROM on which data can be erased electrically either by sector block or for the entire chip Nonvolatile memory retains data when power is turned off FRU An abbreviation of field replaceable unit HPC An abbreviation of Hot Plug Controller The Hot plug controller of component that you can exchange and detach without system shutdown or reboot IDE Bus of easy circuit composition to connect hard disk or CD ROM drive Inlet An intake vent IO BP An abbreviation of IO Back Panel JTAG An abbreviation of Joint Test Action Group It generally indicates the boundary scan architecture of which test method was standardized as EEE1149 1 and its serial port All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 The boundary scan is the architecture that allocates between the core logic and the pin a register called cell equivalent to the test probe and that if it is a shift register enters the input signal from the shift register and examines the output result Neuron The component in which the RCI interface controller operates NVRAM An abbreviation of nonvolatile RAM For ordinary RAM i
269. pen SSH do the following ssh keygen t rsa Generating public private rsa key pair Enter file in which to save the key nome user ssh identity ssh2 key Enter passphrase empty for no passphrase Enter same passphrase again Your identification has been saved in ssh2 key our public key has been saved in ssh2 key pub The key fingerprint is 2c 97 ab 7f a9 be 5a 08 54 82 1f cd 42 e5 64 2b user domain The host key is generated without a passphrase The Privete key is downloaded to XSCF and the public key is not downloaded Next it explains the method of using xscf_dl_sshdata command and downloading the generated host key to XSCF When you use the xscf_dl_sshdata command you need to disable the SSH function of XSCF in the SSH Administration The SSH function is disabled by default To download the host key generated by xscf_dl_sshdata command to XSCF do the following The file extension of the download host key is key opt FJSVmadm sbin xscf_dl_sshdata set1 ssh1 key set2 ssh2 key To check the downloaded host key do the following opt FJSVmadm sbin xscf_dl_sshdata status TYPE FILE SSH1 ssh1 key 1024byte Fri Jun 20 09 00 00 JST 2003 SSH2 ssh2 key 1536byte Fri Jun 20 09 00 00 JST 2003 To delete the downloaded host key do the following opt FJSVmadm sbin xscf_dl_sshdata clr1 opt FJSVmadm sbin xscf_dl_sshdata clr2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 20
270. phase Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 0BP B 21 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 280000FF Message OSRUN JOS Running OBP failed Explanation An OBP call was not completed whille OS runninng OSRUN OS running phase Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 0 OBP 281000FF Message OSRUNJOS Running OS abort Explanation Control is moved to OBP because OS gave up managing any serious trouble OSRUN OS running phase Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 0 OBP 281000XX p Message OS aborted Explanation Control is moved to OBP because OS gave up managing any serious trouble Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 O0BP 2A0000FF Message POFF Power off sequence failed Explanation Power off sequence failed POFF Power off phase Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 0 OBP 2B0000FF Message REBOOT Reboot sequence failed Explanation Reset sequence failed REBOOT Reboot phase Replacement part number FF FF Action Contact a FE Error level report level e
271. plays it only on the OS console connected via serial RS232C port A 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Displays it when an input power source is turned on at MAINTENANCE mode on the mode switch Displays it when the firmware update is performed on the Machine Administration Menu at MAINTENANCE mode on the mode switch Displays three bottoms messages of figure A 1 always when an input power source is turned on and when the firmware update is performed This does not depend on the mode switch status The following is the XSCF s initial diagnose messages KEK WEN CHEK HEWN EK HEN EWEN WEN EN WEN ER EWEN PRIMEPOWER series XSCF ExxVxxLxxxx COPYRIGHT C FUJITSU LIMITED 2003 WHEW WEN CHEK HEWN EK WEN E EWEN HERKEN WEN E EWEN NVRAM initialize Display when NVRAM is formatted self test SDRAM The diagnosis for every parts is started self test complete reset type AC reset reset type SELF reset reset type CPU reset reset type WATCHDOG reset version ExxVxxLxxxx bankO xxxxxxxxx bank xxxxxxxx time YYYY MM DD hh mm ss GMT Display the type of reset NVRAM initialize Display at the PANEL EEPROM all initialize Display depending MAINTENANCE mode PANEL EEPROM initialize dhl gaa FRU initialize SDRAM initialize loading XSCF Ready Standby Code 02000100 XSCF not ready code xxxxxxxx End failure Code 02800200 Current HCP version i
272. power log item The power log items displayed by XSCF are given below 01 AC ON 10 SCF Reset 11 SCF Ready 20 Power on 30 XIR 38 POR 3f Reset Rrelease 40 Shutdown NML 41 Shutdown ALM 42 Power off 50 ACFAIL Table B 2 2 Power log items DC Type Type Source detailed code and explanation 01 AC ON Source ff Nothing 01 PSU ON Detailed code x00000000 When the Explanation Power was turned on input power Source O0C UPS source is the Detailed code x02000000 Explanation Power was turned on by power recovery processing The CPU started to work 10 SCF Reset Source ff Nothing Detailed code x01000000 Explanation The XSCF was reset XSCF self reset Source ff Nothing Detailed code x02000000 Explanation The XSCF was reset It was caused by the watchdog timer Source ff Nothing Detailed code x03000000 Explanation The XSCF was reset ESF detected a XSCF trouble then reset was done 11 SCF Ready Source ff Nothing Detailed code x00000000 Explanation The SCF entered the Ready state 20 Power on Source 00 PANEL SWITCH Detailed code x00000000 Explanation Power on was executed with the switch on the operating panel Source 01 NVRAM TOD Detailed code x00000000 Explanation Power on was executed by the NVRAM TOD timer setting All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 63 Source 01 NVRAM TOD Detailed code x
273. r y n y Return User was added This user needs password to login Hit return key Next Add User Users can be registered up to 8 accounts lt user gt lt group gt others ZZZZZ others abc1234 root a Add user q Quit b Back to previous menu t Go to topmenu h Help Select a q b t h a To add other user account please repeat the same procedure in Add User menu 2 9 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF When the maximum number of account has already been registered you will see following screens Add User Users can be registered up to 8 accounts lt user gt lt group gt others others abc1234 root zzzz5 others zzzz others Zzzz7 others ZZzz8 others q Quit b Back to previous menu t Go to topmenu h Help Number of the accounts will exceeds the limit 8 You need to delete users to add new account Hit return key To Delete user account choose Delete User in User Account Administration Examples Delete User lt user gt lt group gt others others others Select user 1 4 q b t h 2 Return Do you really want to delete this user y n y Return The user was deleted Hit return key Next Delete User lt user gt lt group gt 3 abc1234 others q Quit b Back to previous menu t Go to topmenu h Help Select user 1 3 q b t h When you press the return key then the screen is updated as above To d
274. r TOD Explanation Calendar clock is not operational Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 16100033 Message TTY test error TTY A Explanation ATTY register error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Wanrning 3 POST 162000XX Message HPC3130 error HPC n Explanation A HotPlug functional error was detected XX n 35 0 36 1 37 2 Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 170v0042 Message Ethernet register error LAN 0 v 0 1 2 Explanation ALAN register error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 1710042 Message Ethernet inernal loopback error LAN 0 v 0 1 7 Explanation ALAN loopback error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Wanrning 3 POST 172v0042 Message Ethernet Physical Layer loopback 10Mbps error LAN 0 v 0 1 7 Explanation ALAN loopback error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 173v0042 Message Ethernet PHY loopback 100Mbps error LAN 0 v 0 1 7 Explana
275. r for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830B130n Message CPUDDC n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 42 CPUDDC 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830E000n Message FAN CONTROLLER n access warning Explanation A system control bus access error bus configuration remains redundant was detected Replacement part number 01 SB 00 model 250 R 32 FANJT O 1 FAN 0 3 of model 250 R4 250 P 450 R 450 Q 03 PCI BD 00 FAN 4 7 of model 450 R 450 Q Action For model 250 R Replace the SB For models 250 R4 250 P 450 R 450 Q Replace the SB if fan from 0 to 3 is specified For model 450 Q Replace the PCI board if fan from 4 to 7 is specified Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8310010n Message CPU n FRU data error Explanation An FRU data error on CPU n was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8310020n Message Unknown CPU n FRU IDCODE xx so u
276. r in SCF SDRAM but the correction was incorrect Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0807200 Message SCF SDRAM ECC UE test error Explanation ECC did not detect an uncorrectable error in SCF SDRAM Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0808000 Message UART loop back error Explanation A data receive timeout was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0808100 Message UART compare error Explanation A transmission data compare error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0809200 Message TOD error Explanation A calendar operation error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C080F000 Message SCF CPU reset retry out Explanation SCF cannot complete its resetting properly or WDT reset failed Replacement part number 01 SB 00 Action Replace the SB Contact the system administra
277. ration is added In A mail report was not received from XSCF descriptions of check items are added Glossary In the term Standard consol a description about SSH is added And a description of TELNET 8013 port is added The terms Cluster control software REMCS and SSH are added Summary of Changes in Second Edition The current second edition of this manual differs from previous edition with Revision1 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 principally by containing the menus of Machine Administration function The second edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition with Revision1 Preface In Caution a description is changed that we do not support The DNS function in case of using XSCF Mail function In Caution a description of XSCF SNMP Agent function is deleted Chapter 2 Setting Up XSCF The menu name of Basic configuration and the described section is changed to two new menus Network Configuration and Console Administration The contents are as follows In the menu of Basic configuration each options Basic network configuration and Host name configuration are moved to Network Configuration menu The section of Network Configuration is added In the menu of Basic configuration each options Select Standard console Access con
278. ress 000101FF Mode 20A0 Status 80000000 LIST Address Status Device Class Sub Class 000101FF 99 0001 OA 000102FF 98 0001 07 003001FF 90 4000 05 SCF gt show config value The show config command is used to view the system information number of server CPUs memory capacity part information and the like You may want to check the status of the system by this command when for example you are setting up the system or you change the configuration of system When no option is specified a synopsis of the configuration information for the device is displayed The following is an example of command execution SCF gt show conf ig Model name PWPL 450 Model type gt XXXXXX Machine Versio n 12 Sysytem frequency 220MHz Version gt OO1AA SB Type 0102 CPU No Frequency Serial no All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 1 1100MHz P28000010 1100MHz P26000001 Total Capacity 2048 MB SLOT SLOT SLOT SLOT SCF gt 00 03 04 07 08 11 12 15 512MB 512MB 512MB 512M6 The following table describes the options that can be specified Table 6 11 show config command options Option value Description no option Displays major configuration of the machine scf Displays the XSCF firmware version RCI version and server ID network Displays the GatewayIP Subnetmask Host name IPaddress and SCF Ma
279. rminal Alternatively contact the system administrator The XSCF shell was forcibly terminated while it was being used After login to the XSCF shell if there is no activity for a predetermined time XSCF automatically terminates the shell When the time monitoring function has been enabled and a time has been specified in the XSCF settings forced termination occurs if the time elapses The XSCF Web function was forcibly terminated After login to the XSCF Web function page if there is no activity for a predetermined time XSCF terminates the Web page Since this time monitoring function is always enabled if the predetermined time elapses a message reporting forced termination is displayed the next time an access is made Pressing the OK button closes all frames and causes the login screen to appear Log in again All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Do not know the IP address of XSCF To check the current network configuration choose Network Configuration of the the Machine Administration Menu If it shows no IP address infomations contact the network administrator to get it Could not power on or off the server if you do not have root level authority you cannot power on or off the server For the user authority see Chapter6 How to Use the XSCF Command Shell Could not power on or off the server on the remote panel if you do not have root level authority you cannot power on or off the se
280. rnet Eplorer is added In Cookies a description of in cache only it don t have to be stored is deleted In Logging In to or Out from XSCF a description of Condition of Logging out from XSCF is corrected Chapter 6 How to Use the XSCF Command Shell The commands of net status show shell command are added Anote in the set console device command is added Chapter 7 XSCF SNMP Agent function In Installation case to SystemWalker Descriptions of a setup which calls XSCF WEB function from SystemWalker is added Chapter 8 XSCF Mail Function In Features of the XSCF mail function Description of Sending e mail directly by setting name server is deleted In Setting up the XSCF Mail Function description of name server setting at Step All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1 and Note are deleted At Step1 the Mail administration menu of the Machine Administration menu is described Appendix B XSCF Log Information XSCF Error Log List are corrected In the hardware which detects an error Machine Administration is added Therefore some tables at each error level are added The following error code numbers are corrected 4E20F500 gt 4E20F50n 82130400 gt C2130400 C21110FF gt C2111000 C21111FF gt C2111100 C21112FF gt C2111200 Descriptions of error codes 408055FF 430103FF 431501FF 4E20F00n 4E20F600 501012FF
281. rogram HCP Administration HCP File Operation Update Baseboard Firmware Disk Firmware Administration This window is an example 4 Select HCP File Operation then select Show Register the Supply HCP Select CD ROM and register the firmware by the Machine Administration Menu In this state it is not upgraded yet 5 Return to Hardware Control Program HCP Administration menu Select Update Baseboard Firmware then select Show Register Current Baseboard Firmware At this time the current firmware version is displayed Next selet Update At this time some versions of the registered firmware is displayed Select the firmware version that will be upgraded Using the Machine Administration Menu apply the registered firmware 6 Do the following to complete upgrades When OBP firmware is included in the updated firmware the OS must be restarted to check the applied firmware For about the firmware upgrade information see Readme file in the CD ROM Note A console the XSCF shell a standard console and a XSCF WEB function s browser are disconnected immediately after the update of the firmware without OBP Please login again when you use the XSCF 7 Using the Machine Administration Menu verify the result of the firmware update Select Update Baseboard Firmware in Hardware Control Program HCP Administration menu Then select Show Register C
282. ront panel and back panel hereafter You can also use the XSCF shell commands on the XSCF console to control remote operation of the server and to identify the LED states For information about the XSCF Web function see Chapters How to Use the XSCF Web Function For information about the operating Panel see the User s Manual for the server For information about the XSCF shell commands see Chapter6 How to Use the XSCF Command Shell Table 4 1 outlines the remote Panel Table 4 1 Remote panel components Component Description Indicates the states of the three LEDs POWER LED Indicates whether the power of the server is on ONLINE LED Indicates whether the server has been started up CHECK LED Indicates error of the server and the location of the server Has three buttons for performing operations Power switch Turns power to the server on and off Reset switch Resets the server Front panel Request switch Instructs the system to output an OS dump Note To enable these three switches specify Enable with read write mode at the optton of XSCF Web Administration of XSCF Administration in Machine Administration Menu In addition to log in XSCF with root level authority Indicates one of the three states to which the mode switch is currently set LOCK mode UNLOCK mode MAINTENANCE mode Indicates the states of two LEDs CHECK LED Indicates a ser
283. ror code Message and explanation 4201010n Message PSU n ACFAIL When the input power source is the AC Type PSU n input failure When the input power source is the DC Type Explanation Input power source failure power supply not redundant was detected Replacement part number 41 PSU 0 2 Action Check the installation environment Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and lO back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800000 a Message SCF CPU Illegal Critical input interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800100 i Message SCF CPU Illegal Machine check interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800200 Message SCF CPU Illegal Data storage interrupt Explanation An illegal interrupt occurred Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C0800300 i Message SCF CPU Ill
284. ror level report level error detection source Notice 0 XSCF 6101150n Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101160n Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Recheck the SMTP server or the Name server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6101170n i s Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF B 53 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6101180n Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part number FF FF Action Needs a dump of XSCF Contact the system adm
285. ror level report level error detection source Warning 3 POST 0701000n Message FATAL check1 error CPU n Explanation A coherence error occurred Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST B 36 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 07020030 Message FATAL check1 error DTAG Explanation A DTAG uncorrectable error occurred Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 07030031 Message FATAL check1 error SC Explanation A UPA address parity error occurred SC gt U2P Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 070400XX Message FATAL check1 error U2P n Explanation Master ClassO overflowed n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 070500XX Message FATAL check1 error U2P n Explanation A UPA address parity error occurred U2P gt SC n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 07060030 Message FATAL check1 error DTAG Explanation A DTAG parity error occurred Replacement part n
286. ror level report level error detection source Warning 3 XSCF CD000100 Message SCF FMEM write protect error Explanation A write protection error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF CD000200 Message SCF FMEM update error erase Explanation An erase failure was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF CD000300 Message SCF FMEM update error write Explanation A write failure was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 35 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 CD000400 Message SCF FMEM update error checksum Explanation A checksum error after a write was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF D080000n Message Parts Status Reset Failure Explanation In Machine Administration Menu the status of abnormal parts was reset Replacement part number M Action Replace the replacement part Contac
287. ror occurred in the power supply unit Detected failure on the CPU CPU type X freq XXXXMHz An error occurred in the CPU Detected failure on the power supply unit Parts XXXx 11 U2 Cache correctable Error CPU type X freq XXXXMHz A U2 cache CE occurred Parts XXXx 4 Cache TLB Degrade CPU type X freq XXXXMHz Cache and TLB are Parts XXXxX degraded 1 2 Detected failure on the RCI node ADDRESS XXXXXXXX An RCI node error occurred An error occurred on the Detected failure on the PANEL panel UPS failure An error occurred in the UPS Notification message The parentheses contains error Notification Message in the error log log messages in a notice reporting that parts replacement is not required A 2 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 An abnormal environment condition occurred This message is displayed when an abnormal environment condition such as an inlet warning or an error occurred and parts replacement is not required Detected abnormality of environment Detected failure on the memory module DIMM size xxxxMB Amemory error occurred 1 Detected failure on the PCI card A PCI card error occurred 2 Memory correctable error Amemory CE occurred 2 A DTAG CE occurred 2 DTAG correctable error DATG The part which controls the cache of CPU A configuration error occurred Hardwar
288. rror detection source Alarm 0 0BP 2CO0000FF Message INITO Init 0 sequence failed Explanation Problem is detected during shutting down to OBP INITO Init 0 phase Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 0 O0BP 2E0000FF Message RED RED State exception occurred Explanation ARED state occurred RED RED WDR YXIR phase Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 2E1000FF Message RED Watchdog reset occurred Explanation A watchdog reset occurred RED RED WDR XIR phase Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 2E200000 Message RED Reset Switch Explanation A Reset Switch was pressed RED RED WDR YXIR phase Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 3 O0BP 33000039 Message Autoboot stop No Available TOD Explanation A boot supression for abnormality of TOD time value Replacement part number 01 SB 00 Action There is a possibility of the illegal time setting So please set a time by set tod all command Replace the SB when you will have the same message again after reboot Contact a FE Error level report level error detection source Alarm 0 O0BP 330000FF
289. rror level report level error detection source Alarm 3 OBP 255000XX Message BOOTP network error LAN n XX 42 43 Explanation A network boot error occurred BOOTP Boot phase1 Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 256000XX Message BOOT P network error LAN n XX 42 43 Explanation A network boot error occurred BOOTP Boot phase1 Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 25700044 Message BOOTP IDE error Explanation A CDROM DVD boot error occurred BOOTP Boot phase1 Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 0BP 260000FF Message BOOTB Boot block error Explanation Execution of the boot block was abnormally terminated BOOTB Boot block phase Replacement part number FF FF Action It might not be a correct disk Please confirm the disk Error level report level error detection source Alarm 0 OBP 261 000XX Message BOOTB disk label error p Explanation A disk label error was detected BOOTB Boot block phase Replacement part number 01 SB 00 or 92 PCI 00 08 or 91 DISK 0 5 Action Contact a FE Error level report level error detection source Alarm 3 OBP 262000XX Message BOOTB SCSI error p Explanation A disk boot error was detected BOOTB Boot block phase Repl
290. rror level report level error detection source Alarm 3 OBP 1810003D Message OBPENV eeprom data invalid set default Explanation Abnormality is detected in the panel EEPROM where environment variables of OBP are stored OBPENV About EEPROM phase Replacement part number 02 PANEL 00 Action Contact a FE Error level report level error detection source Alarm 3 0BP 1820003D Message OBPENV eeprom data invalid Explanation Abnormality is detected in the panel EEPROM where system ID information is stored OBPENV About EEPROM phase Replacement part number 02 PANEL 00 Action Contact a FE Error level report level error detection source Alarm 3 OBP 190000FF Message EEBUS Probing Extended ebus device failed Explanation Initialization of the OBP failed EEBUS Ebus node phase Replacement part number FF FF or 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP 1A00000n Message CPU Probing CPU failed Explanation CPU failed while Initialization of the OBP CPU CPU node phase Replacement part number 11 CPU 0 3 Action Replace the CPU Then contact a FE Error level report level error detection source Alarm 3 OBP B 18 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1A0000FF Message CPU Probing CPU failed Explanation Initialization of the OBP failed CPU CPU node phase Replacement
291. rror logs Show event logs Show IPL Initial Program Loading messages Show Mail Report configuration Show Panic messages Show power logs Show REMCS configuration Show shell keyword Show system error status Shutdown request Show recorded thermal history Show version Who is on the XSCF system xir eXternally Initiated Reset The show shell command is used to display a login keyword that can move to the XSCF shell terminal from the Standard console The following is an example of command execution SCF gt show she command Shell keyword code ASCII CODE JEZE SCF gt set shell command The set shell command is used to change a login keyword that can move to the XSCF shell terminal from the Standard console The default value is a tilde plus a period This can be changed on the command of Machine Administration function too This can be changed to a combination of up to seven characters The required authority for this command is root level The following is an example of command execution 6 29 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 6 30 SCF gt set shel command retype kkk SCF gt Note The following is a reference of the command on the Machine Administration function scfshkey 1M NAME scfshkey Display and change the login keyword for XSCF shell SYNOPSYS usr sbin FJSVmadm scfshkey usr sbin
292. rror occurred Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 OBP xx0832yy Message ppp Data Access Error Cp Explanation An illegal trap error occurred Replacement part number 01 SB 00 or 11 CPU 0 3 or 21 SLOT 00 15 Action Contact a FE Error level report level error detection source Alarm 3 OBP xx0864yy Message ppp Fast Instruction Access MMU Miss p Explanation An illegal trap error occurred Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 0BP xx0868yy p Message ppp Fast Data Access MMU Miss Explanation An illegal trap error occurred Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 3 0BP p xx Test phase number XX yy Component number zzz Component name ppp Phase abbreviation Please refer to Table B 1 T and Table B 1 C for details Alarm Warnig Notice Information The content of the error messages might be changed because of the function improvement B 23 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Warning The following table lists warning level errors e g errors in which operation can continue but in a degraded state and the actions to be taken To view errors by error code use XSCF Error Code Table in Section B 4 Alarm 1 Alarm 2 Alar
293. rs of month in English DD Day of the month hh mm ss Hour 24 hour clock minute second XXX TimeZoneName YYYY Year four digit year XSCF Component name Z_ System fault level A Alarm Fatal problem for system W Warning Serious problem but system can keep working N Notice notification Information notification xXxxx Indicates the faulty part If the fault level is I none is displayed And no errorlog nnnnnnnn Eight digit specific error code Message Error message up to 48 characters described in the previous section Additionally system messages and other specific detailed messages are displayed For information about error codes and error messages see Appendix B XSCF Log Information Messages output as a mail report When a server error is detected the XSCF mail function sends a report to the user The mail message includes both the system messages and error messages described in the previous section A 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 For an example of an actually displayed mail message see Chapter 8 XSCF Mail Function Messages output by SNMP agent function When a server error is detected the XSCF SNMP agent function generates a trap The SNMP message contains the error messages For an example of an actually displayed mail message see Chapter XSCF SNMP Agent Function Messages output by the XSCF Web function The XS
294. rtinent function OPERANDS RW The SSH function of the Standard Console port is set RO The SSH function of the Read only Console port is set SCF The SSH function of the XSCF sh port is set enable enables the SSH function of the specified port 2 38 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings disable disables the SSH function of the specified port EXIT STATUS 0 Normal end gt 0 An error occurred NOTE To use the SSH function it is neccessary to have permitted the use of the telnet port of a pertinent function by Machine Administration menu beforehand Until the SSH function is made effective by this command the communication is done by telnet protocol Next Chapter 3 Connecting XSCF to Terminal 2 39 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF 2 40 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server This chapter explains the procedure for connecting consoles or terminals to have a access to XSCF for connecting from UPC or to PC and for construct RCI network This chapter has the following contents Contents 3 1 Connecting Terminals to XSCF 3 2 3 2 Types of XSCF Connection 3 10 3 3 Connecting XSCF to a PC and UPC 3 12 3 4 Connecting of RCI 3 13 3 4 1 Basic configration 3 13 3 4 2 Cluster Configration 3 14 3 4 3 Method of constructing RCI 3 15
295. rts errors and failures by e mail so that S immediate measures can be taken SNMP trap report Enables consolidated control for server S administration in conjunction with SNMP manager Standard console You can access to the OS console and or OBP S S prompt S Supported Not supported Next 1 4 XSCF Monitoring and Linkage to Other Functions 1 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1 4 XSCF Monitoring and Linkage to Other Functions 1 4 XSCF Monitoring and Linkage to Other Functions XSCF monitors the system and log errors in case it happens This section describes the error log and how it is handled by the XSCF functions How Hardware error log is handled by the XSCF functions XSCF logs detected hardware related errors and in parallel informs warning messages This log called as Hardware error log Figure 1 2 shows how an error logged by XSCF is simultaneously reported to users by each of the XSCF functions Server detected Error Logged error a logged gt Logged error reported reported by e mai via SNMP mail funo SNMP agent nctLo Status di by entering a command XSCF shel Location error displayed graphical Web func ion Figure 1 2 Error message handling by function How XSCF logs hardware errors and how the XSCF functions report errors are described below 1 9 All Rights Reserved Copyright C FUJITSU
296. rver When the XSCF Web function has been set to read only mode you cannot power on or off the server Other problems Contact the system administrator When an XSCF dump is required use the Machine Administration Menu For information about obtaining a dump see Appendix 10 XSCF Firmware Upgrade and Dump It is possible setting to display it even by the command of the Machine Administration function since ESF2 5 1 For detail about the command of the Machine Administration function see the Machine Administration Guide for the ESF FAQ Q1 When OS and ESF are not installed can set up the SCF LAN only by XSCF You cannot set up the SCF LAN only by XSCF When OS and ESF are not installed it means that there is no system administrator of the server In the server to which the system administrator is not registered the data integrity of the configuration information cannot be kept Therefore the SCF LAN settings Network configuration cannot be setup After installing OS ESF please set up the SCF LAN Q2 Is IP address allocated by the default for the SCF LAN port IP address is not allocated in the SCF LAN port by the default If the IP address is allocated by the default the IP address might temporarily overlap in each server when you set up the two or more servers at the same time This has the possibility to influence the environment of the user LAN To avoid the confusion the SCF LAN network function is disabled by
297. rwDatagrams ip 6 Counter R ipInUnknownProtos ip 7 Counter R ipInDiscards ip 8 Counter R ipInDelivers ip 9 Counter R ipOutRequests ip 10 Counter R ipOutDiscards ip 11 Counter R ipOutNoRoutes ip 12 Counter R ipReasmTimeout ip 13 INTEGER R ipReasmReqds ip 14 Counter R ipReasmOKs ip 15 Counter R ipReasmFails ip 16 Counter R ipFragOKs ip 17 Counter R ipFragFails ip 18 Counter R ipFragCreates ip 19 Counter R ipAddrTable ip 20 Aggregate NA ipAddrEntry ipAddrTable 1 Aggregate NA ipAdEntAddr ipAddrEntry 1 lpAddress R ipAdEntlflndex ipAddrEntry 2 INTEGER R ipAdEntNetMask ipAddrEntry 3 IpAddress R ipAdEntBcastAddr ipAddrEntry 4 INTEGER R ipAdEntReasmMaxSize ipAddrEntry 5 INTEGER R ipRouteTable ip 21 Aggregate NA ipRouteEntry ipRouteTable 1 Aggregate NA ipRouteDest ipRouteEntry 1 lpAddress R ipRoutelflndex ipRouteEntry 2 INTEGER R ipRouteMetric1 ipRouteEntry 3 INTEGER R ipRouteMetric2 ipRouteEntry 4 INTEGER R ipRouteMetric3 ipRouteEntry 5 INTEGER R ipRouteMetric4 ipRouteEntry 6 INTEGER R ipRouteNextHop ipRouteEntry 7 IpAddress R ipRouteType ipRouteEntry 8 INTEGER R ipRouteProto ipRouteEntry 9 INTEGER R ipRouteAge ipRouteEntry 10 INTEGER R ipRouteMask ipRouteEntry 11 IpAddress R ipRouteMetric5 ipRouteEntry 12 INTEGER R ipRoutelnfo ipRouteEntry 13 ObjectID R ipNetToMediaTable ip 22 Aggregate NA ipNetToMediaEntry ipNetToMediaTable 1 Aggregate NA ipNetToMedialflndex ipNetToMediaEntry 1 INTEGER R ipNetToMediaPhysAddress ipNetToMediaEntry 2 PhysAddres
298. s 1 You can use the Mail Sending function via a SMTP server 2 Development convenience In Chapter10 of this manual the method of firmware update in the Registration from applying of the ESF patch xiv All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter1 Overview of XSCF This chapter provides an overview of the system monitor and control facility eXtended System Control Facility or XSCF This chapter has the following contents Contents 1 1 XSCF Features 1 2 1 2 Types of Connection to XSCF 1 5 1 3 XSCF User Interfaces 1 7 1 4 XSCF Monitoring and Linkage to Other Functions 1 9 1 5 Time synchronization 1 12 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter1 Overview of XSCF 1 1 1 2 XSCF Features XSCF is a system monitor control facility that consists of processors independent of the CPU ona server Even though the server is turned off XSCF is always able to monitor the server and provide a user interface as long as the power is supplying to the system via power cables XSCF is single centralized point for control of cooling system fan units power supply units system status monitor power on and power off of peripheral devices and error monitor XSCF offers several features to achieve greater reliability and availability For instance with using XSCF 1 you can monitor a server over a serial port or Ethernet so that the user can control the server from a r
299. s R ipNetToMediaNetAddress ipNetToMediaEntry 3 lpAddress R ipNetToMediaType ipNetToMediaEntry 4 INTEGER R All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 5 icmp group Table C 5 icmp group MIB OBJECT ID SYNTAX RW icmpInMsgs icmp 1 Counter R icmpInErrors icmp 2 Counter R icmpInDestUnreachs icmp 3 Counter R icmpInTimeExcds icmp 4 Counter R icmpInParmProbs icmp 5 Counter R icmpInSrcQuenchs icmp 6 Counter R icmpInRedirects icmp 7 Counter R icmpInEchos icmp 8 Counter R icmpInEchoReps icmp 9 Counter R icmpInTimestamps icmp 10 Counter R icmpInTimestampReps icmp 11 Counter R icmp InAddrMasks icmp 12 Counter R icmpInAddrMaskReps icmp 13 Counter R icmpOutMsgs icmp 14 Counter R icmpOutErrors icmp 15 Counter R icmpOutDestUnreachs icmp 16 Counter R icmpOutTimeExcds icmp 17 Counter R icmpOutParmProbs icmp 18 Counter R icmpOutSrcQuenchs icmp 19 Counter R icmpOutRedirects icmp 20 Counter R icmpOutEchos icmp 21 Counter R icmpOutEchoReps icmp 22 Counter R icmpOutTimestamps icmp 23 Counter R icmpOutTimestampReps icmp 24 Counter R icmpOutAddrMasks icmp 25 Counter R icmpOutAddrMaskReps icmp 26 Counter R 6 tcp group Table C 6 tcp group MIB OBJECT ID SYNTAX RW tcpRtoAlgorithm tcp 1 INTEGER R tcpRtoMin tcp 2 INTEGER R tcpRtoMax tcp 3 INTEGER R tcpMaxConn tcp 4 INTEGER R tcpActiveOpens tcp 5 Counter R tcpPassiveOpens tcp 6 Counter R tcpAttemptFails tcp 7 Counter R tcpEstabResets tcp 8 Coun
300. s detected Replacement part number A1 FF Action Check the power interface connected to the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyy05 x Message UPS alarm XXXXXXXX CODE XXXXXXXXX Explanation A UPS error was detected Replacement part number A1 FF Action Check the UPS unit connected to the specified IO device Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyy06 x Message Thermal alarm XXXXXXXX CODE XXXXXXXX Explanation A temperature error was detected Replacement part number A1 FF Action Improve the environment Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyy07 x Message AC alarm XXXXXXXX CODE XXXXXXXXX Explanation Abnormality is detected about the power supplied to the system Replacement part number A1 FF Action Check the voltage of power supplied to the system Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 84yyyy08 x Message Diag alarm XXXXXXXX CODE XXXXXXXX Explanation A device specific error was detected Replacement part number A1 FF Action Replace the specified IO device Contact the system administrator ora FE Error level report level error det
301. s exception was detected p Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx00Ayy Message instruction _access_error zzz 9xx00Ayy Explanation An instruction access error was detected p Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx030yy Message data_access_exception CPU n 9xx030yy Explanation A data access exception was detected p Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx032yy Message data_access_error zzz 9xx032yy Explanation A UE of cache or memory was detected p Replacement part number 11 CPU 0 3 or 21 SLOT 00 15 or 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx034yy Message mem_address_not_aligned CPU n 9xx034yy Explanation A data alignment error was detected p Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx04Wyy Message interrupt_level_W CPU n 9xx04Wyy Explanation An illegal interruption was detected Cp Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx060yy Message interrupt_vector zzz 9xx060yy Explanation
302. s included in SNMP TRAP of XSCF enterprise ID agent address generic trap specific trap time stamp variable bindings The object ID which identifies equipment classification Standard Trap number FUJITSU extended Trap number Time of sending trap on the basis of aXSCF SNMP agent starting Additional information of trap The IP address of XSCF which sent trap The unit is 10ms The tables below explain the Standard TRAP and the Fujitsu extended TRAP Table C 13 Standard TRAP TRAP TYPE enterprise ID generic specific variable bindings MEANING trap trap authentication snmp An access by the wrong Failure 1 3 6 1 2 1 4 0 community name was detected by 11 SNMP Agent Table C 14 Fujitsu extended TRAP TRAP TYPE enterprise ID generic specific variable bindings MEANING trap trap scfHardware scfObjects scfServerName The Alarm level error 1 occurred DefectSet 1 3 6 1 4 1 21 6 scfTrapTime in a parts of server 1 1 15 2 1 scfHWErrComment scfHWConfAddr scfHardware scfObjects scfServerName An Alarm level faulty part was DefectUnset 1 3 6 1 4 1 21 6 scfTrapTime exchanged but any Warning level 1 1 15 2 1 scfHWErrComment parts 2 still remains in the server scfHWConfAddr scfHardware scfObjects scfServerName The Warning level error occurred ErrorSet 1 3 6 1 4 1 21 6 scfTrapTime in a parts of server 1 1 15 2 1 scfHWErrComm
303. s not proper ExxVxx recommended Display when the HCP version number of A and B differs Code 03000300 Figure A 1 Initial diagnose messages 2 Normal power on messages The following information message is displayed on the OS console when a normal power on is performed All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Power on request from xxxxx Code 02010100 Waiting for air conditioner XXX min Display when the time is set Code 02010200 Wait for air conditioner XXX min 1 Start power on sequence Code 02010300 Start to power on delay function XXX min Display when the delayed startup is set Code 02010400 I Os power on xxxxxxxx Display when the RCI 1 0 is set 2 I Os power on complete Display when the RCI 1 0 is set 2 Code 02010500 Initialize hardware phase 1 Code 02010600 CPU X idcode xxxxxxxx sc idcode xxxxxxxx Ap Kihi XB X idcode xxxxxxxx Code 0E010m0n U2P X idcode xxxxxxxx initialize hardware phase 2 Initialize SC XB Code 02010800 Initialize hardware phase 3 Initialize CPU Code 02010000 Reset released Code 02010C00 1 The parentheses contains a message at HCP version 0504 or before 2 XXXXXXXX is an I O Unit address which has powered on I Os power on complete is displayed when all I O unit have completed power on Figure A 2 Normal power on messages 3 Normal power off messages The following information m
304. sed All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 D 2 Troubleshooting the Server While XSCF Is Being Used This section explains how to effectively use XSCF when a problem such as no response from the server occurs on the server or when a panic occurs Before contacting service Before contacting service first try the procedure given below This procedure may not only be helpful in solving the problem but also could eliminate the need to make an inquiry 8 If the server does not respond set the mode switch on the operating panel to MAINTENANCE mode 9 Confirmed the system by either of the following methods When you cannot use the XSCF Web function nor the XSCF shell via telnet or serial port a Change the mode switch on front panel to MAINTENANCE position b Connect a terminal to the XSCF s serial port Then Input the login keyword to XSCF shell This combination is the default value For changing the keyword see Chapter6 How to Use the XSCF Command Shell c The system message is displayed with the initialization message before the login prompt of the XSCF shell is displayed When the hardware error has been detected by XSCF any trouble is notified by this system message So please deal based on the message When you can use the XSCF Web function or the XSCF shell via telnet or serial port a Use the XSCF account to log in to XSCF b Connect to the SCF LAN port and use the XSCF Web
305. server Error level report level error detection source Notice 0 XSCF 6110250n Message REMCS communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Recheck the POP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110310n Message REMCS communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110320n Message REMCS communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6110330n Message REMCS communication to POP server n timeout Explanation The timeout occurred by the POP server n Replacement part number FF FF Action Recheck the POP server Error level report level error detection source Notice 0 XSCF 6110340n Message REMCS communication to POP server n failed Explanation The communication failure to POP server n occurred Repla
306. sing xx Explanation Unknown CPU ID code was detected Replacement part number 11 CPU 0 3 Action Replace the CPU Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 8311000n Message SLOT n FRU access error Explanation An FRU access error in SLOT n was detected Replacement part number 21 SLOT 00 15 Action Replace the SLOT memory Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 27 8311010n Message SLOT n FRU data error Explanation An FRU data error in SLOT n was detected Replacement part number 21 SLOT 00 15 Action Replace the SLOT memory Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 83120000 Message PCI BD FRU access error Explanation An FRU access error on the PCI BD was detected Replacement part number 03 PCI BD 00 model 450 Q only Action Replace the PCI board model 450 Q only Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 83120100 Message PCI BD FRU data error Explanation An FRU data error on the PCI BD was detected Replacement part number 03 PCI BD 00 model 450 Q
307. sion is displayed 6 Do the No 5 7 of above Registration from CD ROM Next 10 2 How to Get XSCF Dump Information and Collect Logs 10 5 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 10 XSCF Firmware Upgrade and Dump 10 2 How to Get XSCF Dump Information and Collect Logs This section explains how to get XSCF dump information and to collect logs These operations are performed by the system administrator or a trained field engineer allowed by the system administrator Getting dump and log information using the Machine Administration Menu The Machine Administration Menu that operates on the Solaris OS is used to get log information For the actual menu screen see the Machine Administration Guide for ESF When the user gets log information the user can also get XSCF dump information The following explains how to get log information using the Machine Administration Menu Machine Administration Menu Log Management Menu Log Save This window is an example 1 Display the log management menu from the Machine Administration Menu 2 Choose Log Save 3 Logs will be collected under var opt FJSVmadm log Move the collected log file to any directory if needed 4 Forward collected information to a trained field engineer for more detail analysis Note Since the name of folder that holds the logs and dump file can be changed without notice see the Machine Administration Guide for ESF
308. snmpOutNoSuchNames snmp 21 Counter R snmpOutBadValues snmp 22 Counter R snmpOutGenErrs snmp 24 Counter R snmpOutGetResponses snmp 28 Counter R snmpOutTraps snmp 29 Counter R snmpEnableAuthenTraps snmp 30 INTEGER R Next C 3 Fujitsu exteded MIB All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C 3 Fujitsu Extended MIB The tables below explain the Fujitsu extended MIB lists supported by the XSCF 1 scflnfo group s Table C 9 scflnfo group MIB OBJECT ID SYNTAX R CONTENT Ww scfMachineType scfinfo 1 DisplayString R Model name scfNumberOfCpu scflnfo 2 INTEGER R Number of installing CPU scfSysSerial scfinfo 3 DisplayString R Serial Number scfFirmVersion scfiInfo 4 DisplayString R Firmware version scfHCPVersion scfinfo 5 DisplayString R HCP version scfServerUpTime scflnfo 6 TimeTicks R Agent Uptime 1 scfHostID scflnfo 7 DisplayString R Host ID scfServerID scflnfo 8 DisplayString R Server ID 2 scfState group Table C 10 scfState group MIB OBJECT ID SYNTAX R CONTENT W scfHWErrLevel scfState 1 DisplayString R Faulty parts state 2 scfOSStatus scfState 2 DisplayString R OS state scfDisplay scfState 3 DisplayString R Contents of Remote panel message scfModeSwitch scfState 4 DisplayString R Mode switch 3 scffrapParams group Table C 11 scffrapParams group MIB OBJECT ID SYNTAX R CONTENT Ww scfServerName scffrapP
309. source Alarm 3 POST Alarm Warnig Notice Table B 1 4 Alarm level errors 3 Error code Message and explanation 1100000n Message RSTlinitialization failed Explanation Initialization of the OBP failed RST Reset phase Replacement part number 11 CPU 0 3 or 01 SB 00 or FF FF Action Contact a FE Error level report level error detection source Alarm 3 0BP 1108020n Message RST Watchdog reset Explanation A watchdog reset occurred RST Reset phase Replacement part number 11 CPU 0 3 or FF FF Action Contact a FE Error level report level error detection source Alarm 3 OBP 1108050n Message RST RED state exception Explanation ARED state occurred RST Reset phase Replacement part number 11 CPU 0 3 or FF FF Action Contact a FE Error level report level error detection source Alarm 3 OBP 1108TT00 Message RST Trap occurred TT trap Explanation An illegal trap error occurred RST Reset phase type Replacement part number 11 CPU 0 3 number Action Contact a FE Error level report level error detection source Alarm 3 0BP All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 120000FF Message BI 1 initailization failed Explanation Initialization of the OBP failed Bl1 Initialization 1 phase Replacement part number FF FF or 11 CPU 0 3 Action Contact a FE Error level report level error detection source Alarm 0 OBP 1300000X Message BlI2
310. splay the error information in the received e Mail Sending by REMCS report function All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 6 Other XSCF Commands For more information about MIB see Chapter XSCF SNMP Agent Function and AppendixC XSCF MIB And for information about the mail address settings used by the XSCF Mail function and the REMCS report function see Chapter2 Setting Up XSCF The following is an example of command execution SCF gt logtest alarm SCF gt The following table describes the options that can be specified Table 6 12 logtest command options Option Description alarm Generates an alarm level error warinig Generates a Warning level error notice Generates a notice level error version The version command is used to display the firmware version information of the XSCF and OBP The following is an example of command execution SCF gt version ae XSCF Firmware Information XSCF Version E02V03L01 WEBDATA Version E02V03L01 RASDB Version E02V02L01 xxx OBP Information OBP Version E02V03L01 xxx HCP Information Current Version HCP0201 xxx Hardware Information RCI Version 0001 SCF gt Next 6 7 XSCF Shell Error Messages 6 31 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 6 7 XSC
311. ss from SSH port 8811 SSH 8812 Access from SSH port 8812 SSH 22 Access from SSH port 22 SSL 443 Access from SSL port 443 HTTP 80 Access from HTTP port 80 RS232C Access from the serial port tty a 5 Time at which the authentication failure occurred The time is the local time 6 User name used in the authentication failure 7 IP address of machine that attempted authentication Next 8 7 Contents of Test Mail Notification All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 8 XSCF Mail Function 8 7 8 10 Contents of Test Mail Notification After settings for the XSCF mail function are complete test mail can be sent to verify the settings This section explains the contents of the e mail sent as test mail Date Mon 02 Jun 2003 14 03 16 0900 From XSCF lt rooigghost neme domaln name cch gt To mail address smtp domain name com _ 2 Subject host name XSCF I MAIL SCF Notification TEST MAIL X Mailer COS X maii version 1 0 MINE Version 1 0 3 Content Transfer Encodihg 7bit Content Type text plain char set US ASCIl Content Length 145 M Jun 02 14 03 16 host name XSCF Notification TEST MAIL Name Fujitsu PRIMEPOWER450 PWOLBS111 System Serial No 123456789 000123 Eror Parts Detail LOG This is a Test Mail System Damage Level Figure 8 6 test mail The following describes how to read the contents of mail shown in Figure 8 6
312. stem control bus detected an access error Replacement part number 02 PANEL 00 Action Replace the panel For models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C3030000 Message PANEL SWITCH CONTROLLER access error Explanation The system control bus detected an access error Replacement part number 02 PANEL 00 Action Replace the panel For models 250 R4 250 P 450 R 450 Q Replace the lO back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 3040000 Message LED CONTROLLER O access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 32 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C3050000 Message LED CONTROLLER 1 access error Explanation The system control bus detected an access error Replacement part number 02 PANEL 00 Action Replace the panel For models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF C307000n Message CPUDDC VID n access error Explanati
313. supply unit An uninterruptible power supply unit is connected for backup power control purposes in the event of a power outage This equipment or unit ensures the continuous supply of power without service interruption no interruptions of communication when the normal power equipment fails or a blackout occurs WEBDATA An XSCF firmware resources that implements the XSCF Web function WDT An abbreviation of watchdog timer The watchdog timer built into the CPU checks whether the system operating status is normal If it detects abnormal operation it immediately issues an interrupt to the CPU to notify it of the abnormal condition XB An abbreviation of crossbar XB is a data crossbar that connects the CPU and memory U2P and memory and connects the CPU and U2P XIR An abbreviation of externally initiated reset A XIR resets the server CPU XSCF An abbreviation of Extended System Control Facility XSCF is a system monitor and control facility It is also referred to as the SCF All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005
314. t 8812 Disconnect port 8812 SSH RO port xir The xir command generates an externally initiated reset XIR of the server The server OS console prompt changes to ok The required authority for this command is root level Note Please use this command only when you cannot stop your system in normal procedure due to any software or hardware trouble Do NOT use this command on normal working system For normal working system please use shutdown command WARNING All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell File system could be damaged by executing this command during OS is working shutdown The shutdown command generates to shut down the server This command is ignored when executed during power off or a reset The required authority for this command is root level por The por command is used to perform an immediate system reset of the server The required authority for this command is root level Note Please use this command only when you cannot stop your system in normal procedure due to any software or hardware trouble Do NOT use this command on normal working system For normal working system please use shutdown command request The request command is used to send a panic instruction to the OS The operation performed is the same at that performed when the request switch on the operating panel or remote panel is pressed This command is ignored whe
315. t indicates the total number of errors to be displayed Date Indicates the time local time that the error occurred SvsDamade The system fault level of the error The levels are ALARM y 9 WARNING and NOTICE FaultDetect Indicates the hardware where the error was detected FaultCode A unique error code for identifying the error Detaillnfo Log message ReplaceParts Replacement part and the part number System message output to the console when the error occurred Syslog msg 4 Indicates the error category A Binary error data When a detailed analysis is necessary Fujitsu BinData i engineer uses it For a list of error logs see The following is an exampl Appendix B XSCF Log Information e of command execution All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6 4 XSCF Log View Command SCF gt show error logs x x No 01 32 Date 2002 08 31 08 25 39 SysDamage NOTICE FaultDetect SCF FaultCode 430102FF Detaillnfo FAN speed low CAUSE temperature lower ReplaceParts Syslog msg Notification 00831810 430102FF 02083108 2539FFFF 494E4C45 54207468 65726D61 6C206C6F 71204641 4E207370 65656420 6C6F7700 17140000 00000000 00000000 00000000 SCF gt Note Some of the errors detected by the OS may not be displayed show power logs The show power logs command is used to view all information in the power log including any server power on power off or reset detected by XSCF and POST OBP The
316. t level error detection source Alarm 3 OBP 21000045 Message USB Probing PCI failed USB Explanation Trouble occurred while probing the USB USB USB probing phase Replacement part number 01 SB 00 Action Please replace the USB device Or replace the SB Then contact a FE Error level report level error detection source Alarm 3 OBP 230000FF Message CONSiinstall console failed Explanation Trouble occurred in the console install processing CONS Console setting phase Replacement part number FF FF Action Please confirm values of the OBP environment variable boot device Then contact a FE When you find any message in prior to this message check the earlier message first Error level report level error detection source Alarm 3 OBP 240000FF Message SBinf SBinf failed Explanation SB configration information notification failed SBinf Startup phase Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 0 OBP 250000FF Message BOOTP Boot Process failed Explanation Boot process failed BOOTP Boot phase1 Replacement part number FF FF or 91 DISK 0 5 Action Please confirm values of the OBP environment variable boot device Then contact a FE Please follows that when another one is ahead of this message Error level report level error detection source Alarm 3 OBP All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2500
317. t level error detection source Alarm 3 XSCF C30B140n Message CPUDDC n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 42 CPUDDC 0 3 Action Replace the CPU Or replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30C0000 Message SC access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30C0100 Message SC PLL lock error Explanation A PLL lock error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30D000n Message XB n access error Explanation The system control bus detected an access error Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C30D010n Message XB n PLL lock error Explanation A PLL lock error was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 11 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C30E010n Alarm
318. t related to failure and should be prioritized to NOTIFICATION priority Table 1 3 below shows reaction of XSCF against some typical events This table shows you the types of logs XSCF will take way to display the taken log and method to report it to administrators All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1 4 XSCF Monitoring and Linkage to Other Functions Table 1 3 Types of logs and related functions for some typical events XSCF functions associated with the log Event Log XSCF XSCF SNMP Mail type shell Web agent function function function XSCF logins a ev S N N N Authentication failures a ev S N N 1 S 5 or more attempts within 3 minutes Power on off or reset operations on a ev p S S N the remote panel only P Power on off reset or mode ev p S S N switching operations on the only P S 2 operating panel Power on off operations by p S S N command of XSCF or from an RCI device or the OS Events such as a power failure ev S N N 3 N change in status configuration change and reporting the result of log analysis Hardware related warnings or error err S S S S notifications a access log ev eventlog p power log err Hardware error log S This event can be displayed or reported by this function N This event is not displayed or reported by this function 1 Only failure of an access made with an invalid community name is
319. t the system administrator or a FE Error level report level error detection source Warning 0 XSCF DF000100 Message SCF system down XXXXXXXX Explanation A XSCF system error occurred Replacement part number FF FF Action Needs a dump of XSCF And replace the SB Contact the system administrator or a FE Error level report level error detection source Wanrning 3 XSCF DF001000 Message SCF CPU illegal interrupt Explanation A XSCF CPU illegal interrupt occurred Replacement part number FF FF Action Needs a dump of XSCF And replace the SB Contact the system administrator or a FE Error level report level error detection source Wanrning 3 XSCF x yyyy device address M About part number refer to Table B 1 P for details Alarm Warnig Notice Table B 1 6 Warning level errors 2 Error code Message and explanation 0510000n Message CPU status error CPU n Explanation CPU n was not able to be recognized Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0511000n Message CPU status error CPU n Explanation An error was detected in mounting information on CPU n Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 07000031 Message FATAL check1 error SC Explanation A parity error was detected in SC Replacement part number 01 SB 00 Action Contact a FE Er
320. ta getting 1 Code 0E040800 Getting U2P X All Scan data U2P X all scan data getting 1 Code 0E040900 Log completed Log get complete or No message 1 Code 0E040A00 1 The parentheses contains a message at HCP version 0106 or before Figure A 5 FATAL log collection messages Note The above messages has some which are not displayed depending on a factor The last one of the messages in figure A 5 is displayed whenever each message sequence ended 6 Power on suppression messages The following information message is displayed on the OS console when XSCF suppresses the power on Power on abort Error mail received 1 Code 02011100 Power on abort Error rose in Power on sequence 1 Code 02011200 Power on abort After emergency Power off Code 02011300 Power on abort Emergency Power Off from RCI thread had risen 2 Power on abort RCl error occurred Code 02011400 Power on abort RCI Hardware error had risen 2 Power on abort Power off sequence running Code 02011600 Power on abort Mode switch permission not allowed Code 02011700 Power on abort Power control mode disable Code 02011800 Power on abort UPA frequency is out of range Code 02011900 Power on abort UPA frequency expectant value is out of range 2 1 This is a message at HCP version 0504 or before And it is not displayed at HCP version 0601 or later 2 The parentheses contains a message at HCP version 0504 or before Figure A 6
321. tatus 0 7 bit 0 valid bit bit 1 Mount information bits 2 3 Reserved bit 4 Alarm level bit5 Warning level bit6 Notice level Standby level bit7 Sensor abnormal Detailed code x02mmagqss yyyyyyyy yyyyyyyy YYYYYYYY YYYYYYYY Explanation The part was removed The definitions from mm to ss are the same as described above y s the the serial number before replacement without FAN or PSU Detailed code x81mmqq00 Explanation A fault part was added The definitions from mm to qq are the same as described above 71 DevState E Unit status display Detailed code xqqqqqqqq Explanation The status of the unit was displayed unit dependent command parameter qqqqqqqq indicates the C0 Console Console event Detailed code xVVpp0000 Explanation A console event occurred VV indicates the detailed event pp indicates the switching source The definition of VV is as follows x01 The console was switched from the TTY A console to the SCF LAN console x02 The console was switched from the SCF LAN console to the TTY A console The definition of pp is as follows x00 The console was switched by Machine Administration Menu x01 The console was switched by SCF Shell C1 Access SCF access event Detailed code xVVmm0000 xxxxxxxx yyyyyyyy yyyyyyyy Explanation An SCF access event occurred VV indicates the access type mm the login logout sta
322. te NA Not Access 2 interface group Table C 2 interface group MIB OBJECT ID SYNTAX RW ifNumber interfaces 1 INTEGER R ifTable interfaces 2 Aggregate NA ifEntry ifTable 1 Aggregate NA iflndex ifEntry 1 INTEGER R ifDescr ifEntry 2 DisplayString R ifType ifEntry 3 INTEGER R ifMtu ifEntry 4 INTEGER R ifSpeed ifEntry 5 Gauge R ifPhysAddress ifEntry 6 PhysAddress R ifAdminStatus ifEntry 7 INTEGER R ifOperStatus ifEntry 8 INTEGER R ifLastChange ifEntry 9 TimeTicks R iflnOctets ifEntry 10 Counter R iflnUcastPkts ifEntry 11 Counter R iflnNUcastPkts ifEntry 12 Counter R iflnDiscards ifEntry 13 Counter R iflnErrors ifEntry 14 Counter R iflnUnknownProtos ifEntry 15 Counter R ifOutOctets ifEntry 16 Counter R ifOutUcastPkts ifEntry 17 Counter R ifOutNUcastPkts ifEntry 18 Counter R ifOutDiscards ifEntry 19 Counter R ifOutErrors ifEntry 20 Counter R ifOutQLen ifEntry 21 Gauge R ifSpecific ifEntry 22 ObjectID R 3 at group Table C 3 at group MIB OBJECT ID SYNTAX RW atTable at 1 Aggregate NA atEntry atTable 1 Aggregate NA atlflndex atEntry 1 INTEGER R atPhysAddress atEntry 2 PhysAddress R atNetAddress atEntry 3 NetworkAddress R All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C 3 4 ip group Table C 4 ip group MIB OBJECT ID SYNTAX RW ipForwarding ip 1 INTEGER R ipDefaultTTL ip 2 INTEGER R iplnReceives ip 3 Counter R ipInHdrErrors ip 4 Counter R ipInAddrErrors ip 5 Counter R ipFo
323. tep4 Connection Check After the setting the Machine Administration function checks the connection E mail is send from REMCS center when the setting is normality and check it please Next Chapter 10 XSCF Firmware Upgrade and Dump All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 10 XSCF Firmware Upgrade and Dump This chapter explains how to upgrade the XSCF firmware obtain a dump and record logs This chapter has the following contents Contents 10 1 Upgrading the XSCF Firmware 10 2 10 2 How to Get XSCF Dump Information and Collect Logs 10 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 10 1 Chapter 10 XSCF Firmware Upgrade and Dump 10 1 Upgrading the XSCF Firmware This section explains how to upgrade the XSCF firmware Before upgrading firmware Note the following before upgrading firmware Firmware upgrades are performed by the system administrator or a trained field engineer allowed by the system administrator with root level authority When the firmware upgrades are completed the system uses the firmware data updated newly When you upgrade the firmware please do not return the number of the firmware version to old number of version Failure case of the Firmware Update Because the current firmware data have been backed up to the server so even if you fail in the Firmware Upgrades the system continues running normally Only when you succeed in th
324. ter R tcpCurrEstab tcp 9 Gauge R tcpInSegs tcp 10 Counter R tcpOutSegs tcp 11 Counter R tcpRetransSegs tcp 12 Counter R tcpConnTable tcp 13 Aggregate NA tcpConnEntry tcpConnTable 1 Aggregate NA tcpConnState tcpConnEntry 1 INTEGER R tcpConnLocalAddress tcpConnEntry 2 lpAddress R tcpConnLocalPort tcpConnEntry 3 INTEGER R tcpConnRemAddress tcpConnEntry 4 lpAddress R tcpConnRemPort tcpConnEntry 5 INTEGER R tcpInErrs tcp 14 Counter R tcpOutRsts tcp 15 Counter R All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C 5 C 6 7 udp group Table C 7 udp group MIB OBJECT ID SYNTAX RW udpInDatagrams udp 1 Counter R udpNoPorts udp 2 Counter R udpInErrors udp 3 Counter R udpOutDatagrams udp 4 Counter R udpTable udp 5 Aggregate NA udpEntry udpTable 1 Aggregate NA udpLocalAddress udpEntry 1 lpAddress R udpLocalPort udpEntry 2 INTEGER R 8 snmp group Table C 8 snmp group MIB OBJECT ID SYNTAX RW snmpInPkts snmp 1 Counter R snmpOutPkts snmp 2 Counter R snmpInBadVersions snmp 3 Counter R snmpInBadCommunityNames snmp 4 Counter R snmpInBadCommunityUses snmp 5 Counter R snmpInASNParseErrs snmp 6 Counter R snmpinTotalReqVars snmp 13 Counter R snmplInTotalSetVars snmp 14 Counter R snmpInGetRequests snmp 15 Counter R snmpInGetNexts snmp 16 Counter R snmpInSetRequests snmp 17 Counter R snmpInGetResponses snmp 18 Counter R snmplnTraps snmp 19 Counter R snmpOutTooBigs snmp 20 Counter R
325. test message is delivered to the administrator REMCS settings menu operation In the beginning choose REMCS Environment Setting via XSCF in Remote Customer Support System REMCS Setup menu of the Machine Administration Menu Examples oshostname Remote Customer Support System REMCS Setup menu Series name PRIMEPWR P Model name PWOLBS 1 1 1 Check code MH Serial No 3456 7 8 HHH 1 Registration 2 REMCS Environment Setting 3 REMCS Operation 4 Change Connection Type 5 Software Investigation Information Collection 6 REMCS Environment Setting via XSCF q Quit b Back to previous menu t Go to top menu h Help Select one 1 6 q b t h 6 2 31 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF REMCS via XSCF settings Server settings Next choose the option number of Update in REMCS Environment Setting via XSCF menu And enable the REMCS via XSCF Then specify the server Examples oshostname REMCS Environment Setting via XSCF REMCS via XSCF Disabled An asterisk indicates an indispensable item 1 Update 2 Send Test Mail q Quit b Back to previous menu t Go to top menu h Help Select one 1 2 q b t h 1 Return REMCS via XSCF Disabled Do you want to change the settings y n q y Return REMCS via XSCF 0 Disable 1 Enable Enter disable or enable 0 1 1 Return SMTP Server1 name smtp server Do you want to change the settings y
326. the LAN port use the following procedure 1 On a Standard console that is connected to serial port start up the Machine Administration Menu use the Console Administration option of the XSCF Administration Menu to set the output destination of the standard console to the LAN port 2 From that point the standard console connected via the serial port tty a does not display the console Make sure that the standard console terminal connected via the LAN port displays the console Note If the Machine Administration Menu cannot be used or the console cannot be used via LAN port please use the Console you can access from PC which is directly connected to XSCF by serial port tty a Then login to the XSCF Shell and set the console to serial with set console device command To change the output destination of the standard console connected via the LAN port to the serial port tty a forcibly when you don t set up User Account Administration use the following procedure 3 8 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 1 Connecting Terminals to XSCF Power off the server Connect the console terminal to the serial port tty a Set the mode switch on the server front panel to UNLOCK mode Push the Power switch button for 10 seconds or more The ONLINE LED and the CHECK LED on the front panel blink several times This means that the standard console change to the serial port tty a 5 Make sure th
327. the MODE switch is MAINTENANCE mode If you forget to return the MODE after the MODE switch is changed to MAINTENANCE mode the break signal might be issued to the server and OS might be downed After completing the setting please set the MODE switch back to the setting for normal operation LOCK For your information When graphic card is installed default values of input device and output device are as follows input device keyboard Keyboard directly connected system output device screen Graphic board Therefore if keyboard and graphic board are mounted on the server they are used as the standard console If not mounted the options are not valid and ttya is the standard console 3 17 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 3 Connecting XSCF or Server 2 Modify the Console definition of CDE 1 Start up the OS by single user mode 2 Update the next file usr dt config Xservers Change Console to none in the last line of this file 0 Local local_uid console root usr openwin bin Xsun 0 nobanner 0 Local local_uid none root usr openwin bin Xsun 0 nobanner 3 This configuration takes effect after the next server reset 3 Stop the port monitor ttymon when the console is set to the basic serial port 1 Start up the OS by single user mode 2 Enter the following commands usr lib saf sac t 300 amp usr sbin pmadm d p zsmon s ttya 3 This con
328. the OS console to the tty a Especially when you use the graphic card For more detail about changing the console to tty a see Chapter3 Connecting XSCF or Server All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 3 1 Connecting Terminals to XSCF Port types and connected terminal types As shown in Figure 3 1 the ports that XSCF can be connected are the two ports listed below For the output destination of the OS console standard console use the Administration of the Machine Administration Menu to select one or the other when it s shipped from factory is the serial port tty a way on both ports workstation connected only to the serial port tty a Serial port tty a When a terminal is connected to the serial port tty a the XSCF shell can be used Ethernet Console The default port The XSCF function operates the same Note however that the XSCF Web function cannot be used on a PC and The XSCF shell can be used when telnet or SSH on a terminal is connected to Ethernet LAN port hereafter enabled from a web browser In addition you can use the XSCF Web function if The following table lists the types of terminals connected to each port shown in Figure 3 1 and the port numbers Table 3 1 Connected terminal types Port Terminal type Port number LAN port Terminal dedicated to XSCF shell telnet 8010 You can use the XSCF shell with telnet or SSH SSH 8810 connecti
329. the destination of console output to the serial port tty a or tty b was used on a XSCF shell Besides it has been changed similarly from the Machine Administration Menu Execute the show event log command to view any changes to console operation if you are in the environment which cannot use the XSCF shell terminal when you don t set up User Account Administration you are able to change the standard console to the serial port tty a forcibly For the processing to change see Chapter 3 Connecting XSCF to Terminal A console the XSCF shell or a standard console was suddenly disconnected After someone set Network Configuration or Name Server Configration of the XSCF administration menu or execute the firmware update on the Machine Administration Menu immediately a console of the XSCF shell and a standard console are disconnected Please login again when you use the XSCF XSCF shell was suddenly disconnected while using SSH After login to the XSCF shell if there is no activity for a predetermined time XSCF automatically terminates the shell When the time monitoring function has been enabled and a time has been specified in the XSCF settings forced termination occurs if the time elapses SSH cliant of Solaris Secure Shell or Open SSH disconnect by entering a keyword tilde period A mail report was not received from XSCF XSCF does not report all events It sends mail for faulty parts an authenticat
330. the node number of RCI HOST which request the power off to this system Source 18 HTTP Detailed code x00000000 Explanation Power off was executed via HTTP Source 81 SCF Self Detailed code x00000000 Explanation Power off was executed due to during the PON reset sequence The power off is informed via SCF 50 ACFAIL 50 PSU OFF When the input power source is the DC Type Source ff Nothing Detailed code x00000000 Explanation Input power source failure occurred pl In PRIMEPOWER250 450 there are no logs from the system console 01 AC ON 10 SCF Reset 11 SCF Ready 20 Power on 30 XIR 38 POR 3f Reset Rrelease 40 Shutdown NML 41 Shutdown ALM 42 Power off 50 ACFAIL Information The content of the power logs might be changed because of the function improvement B 68 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Next B 3 XSCF Event Logs List B 69 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 B 3 XSCF Event Logs List This section lists all event log information displayed when the show event logs command is executed on the XSCF console The following table explains the items in event log list For information about a command to display event log and options to the command see Chapter6 H ow to Use the XSCF Command Shell Table B 3 1 How to read the event log list Source Type of event causing an entry in the event log and the
331. the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830B0B00 Message DDC C n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830B0D0n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and IO back panel Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 26 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 830B0F0n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB Or for models 250 R Replace the PSU CAGE For models 250 R4 250 P 450 R 450 Q Replace the Power board and O back panel Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830B110n Message PSU n xx xxV expect xx xxV Explanation An abnormal voltage error was detected Replacement part number 41 PSU 0 2 Action Replace the PSU Or Replace the SB O
332. the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6100330n Message Mail communication to POP server n timeout Explanation The timeout occurred by the POP server n Replacement part number FF FF Action Recheck the POP server Error level report level error detection source Notice 0 XSCF 6100340n Message Mail communication to POP server n failed Explanation The communication failure to POP server n occurred Replacement part number FF FF Action Recheck the POP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF B 52 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 6101000n a 7a Message Mail illegal SMTP server n specified Explanation An illegal SMTP server name was specified Replacement part number FF FF Action Recheck the SMTP server name Error level report level error detection source Notice 0 XSCF 61010100 i Message Mail no SMTP server specified Explanation SMTP server has not been specified Replacement part number FF FF Action Specify SMTP server Error level report level error detection source Notice 0 XSCF 6101100n p Message Mail Name Resolution of SMTP server n failed Explanation Name Resolution of SMTP server failed Replacement part numb
333. tion Someone might have been logging in to XSCF from the same account You can t log in from the account until a person who logged in to XSCF will log out You might have terminated without log out You can t log in from the account until XSCF Auto disconnect time passes But when you want to use the account immediately please do the following 1 Log in to XSCF Web function from another account and check the elapsed time from the last access time about the account by the access status page 2 Update the Auto disconnect time to the check time as above by Machine Administration Menu 3 Login to the XSCF Web Function from the account 4 Change the Auto disconnect time to the original one Forgot the authentication information for the XSCF Web function Since authentication of XSCF Web function is the same as authentication for the XSCF shell see the explanation above Forgot login password for XSCF Failed the first access to the XSCF Web function after log in Check whether the browser accepts the cookie in its settings The Web screen of the XSCF Web function is not displayed correctly The screen might not be displayed correctly because of the version of the browser See Supported browsers in Chapter5 How to Use the XSCF Web Function and switch to the latest browser Could not add an XSCF user Check the number of XSCF users For the number of users see Chapter2 Setting Up XSCF and Chapter 3 Connecting XSCF to Te
334. tion ALAN loopback error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 1740004n Message Ultra320 Registers error SCSl n Explanation A SCSI register error was detected n 0 1 Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 17500043 Message GIGA Ether Registers error LAN 1 Explanation ALAN register error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 17600044 Message IDE Registers error IDE Explanation A IDE register error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Wanrning 3 POST B 40 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 17700045 Message USB error USBC Explanation A USB error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 17710045 Message USB error USBC Explanation A USB error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 8xx008yy Message instruction_access_exception CPU n 9xx008yy Explanation An instruction acces
335. tion Next choose Management Information in SNMP Administration menu Examples Management Information 1 SysContact name 2 SysName 3 SysLocation 4 3F ABC u Setup Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 u q b t h 2 Return Enter SysName To clear information just type in return key Input Patty SCF Next Management Information 1 SysContact name 2 SysName Patty SCF 3 SysLocation 4 3F ABC u Setup Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 u q b t h u Return Are you sure y n y Return Setting has completed Hit return key 2 22 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings Register Community Next select Register Community in SNMP Administration menu Examples Register Community a Add New Community q Quit b Back to previous menu t Go to topmenu h Help Select a q b t h a Return Enter community name public Next Administration of Community public 1 SNMP Manager Address 2 SNMP Trap Notification disable u Save Configuration q Quit b Back to previous menu t Go to topmenu h Help Select 1 3 u q b t h 1 Return Enter SNMP Manager address 192 168 10 123 Next Administration of Community public 1 SNMP Manager Address 192 168 10 123 2 SNMP Trap Notification disable u Save Configuration q Quit b Bac
336. tion Recheck the SMTP server After the re setting if it will fail again needs a dump of XSCF Contact the system administrator or a FE Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111220n Message REMCS setting of SMTP server n failed Explanation The setting failure of SMTP server n was detected Replacement part number FF FF Action Needs a dump of XSCF Contact the system administrator or a FE Needs a dump of XSCF Contact the system administrator or a FE Error level report level error detection source Notice 0 XSCF 6111310n Message REMCS illegal REMCS parameter specified Explanation Illegal the SMTP server name Destination address Sender address or XSCF host name was specified Replacement part number FF FF Action Recheck the SMTP server name Destination address Sender address and XSCF host name Error level report level error detection source Notice 0 XSCF SITAN Message REMCS communication to SMTP server n timeout Explanation The timeout occurred by the SMTP server n Replacement part number FF FF Action Recheck the SMTP server Error level report level error detection source Notice 0 XSCF 6111330n Message REMCS communication to SMTP server n failed Explanation The communication failure to SMTP server n occurred Replacement part number FF FF Action Recheck the SMTP server
337. tion Remarks Enable Disable Specify whether to enable or disable http XSCF Web function is XSCF Web server for XSCF Web function disabled by default To invalidate the operation to the swithes on remote panel choose read only mode Select Locale Specify the locale for Web pages The default setting is C Specify either of the following locales C English ja Japanese Appearance _of Specify whether to display Web pages Web pages are displayed Web Page graphically or in text in text by default Access Control Specify the IP address of a host from which No default setting has access is allowed Specify up to 16 hosts been specified Note In this case access from any hosts is permitted XSCF Web Administration menu operation In the beginning select Enable Disable XSCF Web from XSCF Administration menu of the Machine Administration Menu by its number Examples XSCF Administration 1 Network Configuration 2 User Account Administration 3 Console Administration 4 XSCF Web Administration 5 SNMP Administration 6 Mail Administration q Quit b Back to previous menu t Go to topmenu h Help Select 1 6 q b t h 4 Enable Disable XSCF Web Next configure Enable Disable XSCF Web in XSCF Web Administration menu Examples 2 16 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 2 2 Specifying the XSCF Settings XSCF Web Administration 1 Show Curr
338. tion address for the mail in advance For information about specifying the destination address see Chapter2 Setting Up XSCF Access status monitoring The XSCF Web function monitors the accounts of XSCF users who are logging in to XSCF If login to XSCF has been successful but no access is made for a certain time an authentication timeout occurs and the XSCF Web function logs the user out If an attempt is made to access the XSCF Web function after a timeout a dialog box reporting an authentication timeout is displayed The top page is then displayed To use the XSCF Web function again log in to XSCF again The authentication timeout setting can be changed For details of specifying the authentication timeout setting see Chapter2 Setting Up XSCF Logging out from XSCF To exit the XSCF Web function log out from XSCF on the index page If you do not log out and simply terminate the XSCF Web function connection you may not be able to log in to XSCF again from the same account for a certain time Attempt of login after authentication timeout will be refused with following condition and period Condition Case1 The cookies is deleted Casez2 You try to login to an another browser Time during which login refused The maximum time during which login will be refused is determined by the authentication timeout setting For example if 30 minutes is specified as the timeout setting and if you have accessed XSCF for 10 minutes whe
339. tion source Alarm 3 XSCF x yyyy device address Alarm Warnig Notice Table B 1 3 Alarm level errors 2 Error code Message and explanation 020000F2 Message System Config Error No CPU fail Explanation No CPU is operational This could happen when OS degrades all CPU s Replacement part number FF FF Action Contact a FE Error level report level error detection source Alarm 3 POST 0300003A Message flash memory check sum error FROM 0 Explanation A flash memory checksum error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 0300003B Message flash memory check sum error FROM 1 Explanation A flash memory checksum error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 0310003C Message SRAM Data Line error SRAM Explanation A SRAM data line error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST 0320003C Message SRAM Address Line error SRAM Explanation A SRAM address line error was detected Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Alarm 3 POST B 16 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 0330003C Message SRAM Data error SRAM Expla
340. tion source Warning 0 XSCF 80805100 Message XSCF reserved bank checksum error Explanation A reserved bank checksum error was detected Replacement part number 01 SB 00 Action Replace the SB However if the error was detected during a firmware upgrade or after a failure to upgrade firmware retry the upgrade If the upgrade still fails replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 80805400 Message SCF FMEM checksum error Explanation Check sum error is detected in flash memory Replacement part number 01 SB 00 Action Replace the SB However if the error was detected during a firmware upgrade or after a failure to upgrade firmware retry the upgrade If the upgrade still fails replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 80805600 Message SCF FMEM update unfinished Explanation Update of firmware is not properly finished Replacement part number 01 SB 00 Action Retry the update Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 24 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 80809000 Message TOD stop Explanation Stop of calendar timer is detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE
341. to log in to XSCF five or more consecutive times within 3 minutes due to invalid acount or password a login failure is e mailed to the system administrator When a user successfully logs in to XSCF but the user leaves the session without any activities for a specified length of time XSCF automatically logs the user out 1 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter1 Overview of XSCF For information about the how to log in to XSCF see Chapter6 How to Use the XSCF Command Shell For information about authentication and the XSCF Web function see Chapter5 How to Use the XSCF Web Function For information about registration of accounts and mail settings see Chapter2 Setting Up XSCF The table below shows which XSCF functions can be used on either type of connection Table 1 1 XSCF functions usable on the serial port and SCF LAN Ethernet a SCF LAN Function Description Serial port Ethernet XSCF shell Monitors the server S S The status of the server can be checked Server power can be controlled from a remote location Server power can be turned on and off and the system can be rebooted from a remote location Displays the server configuration The internal configuration of the server can be checked XSCF Web Provides the same functions as the functions of the S function XSCF shells but provides graphical displays for easier operation Mail report Repo
342. tor or a FE Error level report level error detection source Alarm 3 XSCF C1000100 Message System hangup RESET Explanation A startup monitoring timeout error was detected Replacement part number 01 SB 00 Action Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C1000200 Message System hangup OBP Explanation An OBP monitoring timeout error was detected Replacement part number 01 SB 00 Action Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF B 6 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C1001100 Message System hangup OS Level 1 Explanation An interrupt ACK monitoring error was detected while OS was working Replacement part number FF FF Action Check the Software by the panic dump Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source Alarm 3 XSCF C1001200 Message System hangup OS Level 2 Explanation An interrupt ACK monitoring error was detected while OS was not working Or after an interrupt ACK monitoring error was detected panic failed Replacement part number FF FF Action Check the Software by the XIR log Replace the SB or CPU Contact the system administrator or a FE Error level report level error detection source
343. trol of console port and Auto disconnect administration are moved to Console Administration menu The section of Console Administration is added The section of Basic configuration is deleted Option and description of Name server configuration in all menu is deleted In Chapter8 and AppendixD descriptions of DNS function or Name server configuration are deleted at the same time In Console Administration a description of Caution is added in Access Control of Read only Console s Remarks of Table 2 3 Chapter 3 Connecting XSCF or Server In Connecting Terrminals to XSCF descriptions are added as follows A description of Read only console is added in Table3 1 A description of break is added In How to Configure RCI the definition of Automatic power on prohibition mode after the forced power off in the mode mode of power supply for remote control is added How to change the input output destination of OS console to tty a is added Chapter 4 How to Use the Remote Panel In Before using the remote Panel a description of Basic settings is changed to Network settings and Console settings Chapter 5 How to Use the XSCF Web Function In Table 5 1 XSCF Web function pages a description of Authentication page is added In Function to be enabled on the browser Items are corrected as follows A description of option setting on Microsoft R Inte
344. ts contents are lost when power is no longer supplied NVRAM however retains its contents when power is turned off OBP FMEM An FMEM for the OBP See FMEM Panel A part on the front of a server that contains the power switch button LEDs and similar items used by the operator Panic Abnormal termination of the OS PC 1 An abbreviation of personal computer 2 An abbreviation of Power Control PCI An abbreviation of Peripheral Component Interface which is an IEEE standard The PCI is one of the standards used for installation of expansion boards in a PC or workstation and often indicates the location of the expansion board on the motherboard PCI BD A PCI board PLL An abbreviation of phase locked loop A phase coherent loop the PLL is a circuit technology that generates an output signal having a frequency and phase adjusted to those of the input signal POST OBP An abbreviation of Power On Self Test OpenBoot PROM The hardware initial diagnostics function for hardware that is executed when power is turned on POWER BD A POWER board The board for power supply distribution PROM An abbreviation of programmable ROM PROM is ROM to which data can be written PSU An abbreviation of power supply unit PSU CAGE A box which stores PSU RAS An abbreviation of reliability availability and serviceability RAS DB An XSCF firmware resource that implements the RAS function in XSCF RCI An abbreviation of R
345. tus xxxxxxxx the IP address of the access source and yy the account name The definition of VV is as follows x10 Access to XSCF by telnet RW x12 Access to the telnet shell x20 Access to the SSL x21 Access to the HTTP x40 Access to the serial port x50 Access to the SSH RW port 22 x51 Access to the shell port 8810 by SSH x52 Access to the SSH RO port 8811 x53 Access to the SSH RO port 8812 The definition of mm is as follows x01 Logged in to the SCF x02 Logged out from SCF x03 SCF forcibly disconnect user session due to inactivity timeout B 73 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 C2 Author Detailed code xVV000000 xxxxxxxx yyyyyyyy yyyyyyyy Authentica Explanation An authentication failure event occurred when SCF was accessed VV tion failure indicates the access type xxxxxxxx the IP address of the access source and yy the event account name that failed last The definition of VV is as follows x10 Access to XSCF by telnet RW x12 Access to the telnet shell x20 Access to the SSL x21 Access to the HTTP x40 Access to the serial port x50 Access to the SSH RW port 22 x51 Access to the shell port 8810 by SSH x52 Access to the SSH RO port 8811 x53 Access to the SSH RO port 8812 C3 CPUReq Detailed code xVV000000 n
346. twork Configuration on the command line please perform the scfreset 1M command to reflect the setting For details of these three commands of the Machine Administration function see the command reference in the Machine Administration Guide for the ESF The commands are at ESF2 5 1 or later Information The layout and the content of the menu show a sample It might be changed because of the function improvement 2 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF 2 2 2 User account administration Specify a user account for the XSCF shell The User account administration must be made The following table lists the settings and their functions Network Configuration User Account Administration Console Administration XSCF Web Administration SNMP Administration Mail Administration REMCS Administration SSH Administration Table 2 2 XSCF User account administration Item Description Remarks Account setting Specify an XSCF user account to be added or Up to 8 users including deleted Specify a group ID from root others root can be registered The following are the account levels Specify an account name root of up to 8 characters This account level permits the use of all shell commands others This account level permits the use of only some shell commands For more information see Chapter6 How to Use the XSCF Command Shell Update password
347. type code Detaled Coge aay Explains the meaning of a detailed code occurring in the event log explanation The event log items displayed by the XSCF are given below 01 FAN 02 Power 03 NVRAM 04 External 05 UPS 06 Thermal 07 PDOWN 08 Nodeself 09 Mount Oa Change 60 SysInfo 61 Panic 62 Config 71 DevState CO Console C1 Access C2 Author C3 CPUReq C4 Panel C5 RCI C6 Setup C7 EXTInfo C8 LogAnlyz C9 Tempinfo Ca SCFshell Cb Powerlog Table B 3 2 Event log items Source Detailed code and explanation 01 FAN Detailed code xVVnn0000 Fan error Explanation A fan error occurred VV indicates the detailed event and nn indicates the tel fan number The definition of VV is as follows x01 Fan speed decreased x02 Rotation of the fan stopped x03 Afan mounting error occurred B 70 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 02 Power Power supply error el Detailed code xVVnnyy00 Explanation A power supply error occurred VV indicates the detailed event nn indicates the voltage type and yy indicates the power supply unit number The definition of VV is as follows x01 Alow voltage warning occurred x02 Alow voltage alarm occurred x03 An overvoltage warning occurred x04 An overvoltage alarm occurred x05 A power supply error occurred x11 A voltage recoverd normally The definition of nn is as follows x01
348. type of system is installed in the same area it may be difficult to find out the target system By specifying mode option to this command you can change the state of CHECK LED to specified state With help of CHECK LED you may be able to locate the target system easier After found location cancel the forced state of CHECK LED by specifying mode off option Note that the mode and status options are mutually exclusive For more information about the panel LEDs see the User s Manual for the server The following is an example of executing a command that first causes the CHECK LED to blink and then cancels the action SCF gt nodeled status CHECK Amber OFF CHECK Rear OFF SCF gt nodeled mode blink led check SCF gt nodeled status CHECK Amber BLINK Guide LED CHECK Rear BLINK Guide LED SCF gt nodeled mode off led check SCF gt nodeled status CHECK Amber OFF CHECK Rear OFF SCF gt nodeled status led all FRONT LED POWER Green OFF ONLINE Green OFF CHECK Amber OFF REAR LED s s ss ss s SCF READY Green ON CHECK Amber OFF SCF gt The following table describes the options that can be specified All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell Table 6 3 nodeled command options Option Description No options specified The stat
349. umber 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 0710000n Message FATAL check2 error CPU n Explanation A FATAL detected by CPU occurred Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0711000n Message FATAL check2 error CPU n Explanation A UPA address parity error occurred CPU gt SC Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0712000n Message FATAL check2 error CPU n Explanation Master ClassO overflowed Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 0713000n Message FATAL check2 error CPU n Explanation Master Class1 overflowed Replacement part number 11 CPU 0 3 Action Contact a FE Error level report level error detection source Warning 3 POST 07140031 Message FATAL check2 error SC Explanation A UPA address parity error occurred SC gt CPU Replacement part number 01 SB 00 Action Contact a FE Error level report level error detection source Warning 3 POST 080000XX Message Timer1 increment error U2P Timer n Explanation A U2P timer error was detected n XX 0 08 1 09 2 0a 3 0b Replacement part number 01 SB 00 Action Contact a F
350. urrent Baseboard Firmware Check whether the upgraded firmware version is displayed Registration from a remote host 1 The REMCS agent function can download the firmware data to a work directory This is initiated 1 when operator manually requested or 2 when periodic connection to the 10 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 10 XSCF Firmware Upgrade and Dump REMCS center is made and new firmware is available Since these functions are REMCS agent functions see the REMCS Agent Operator s Guide for ESF for more information 2 Display Hardware Control Program HCP Administration menu from the Machine Administration Menu 3 Select HCP File Operation then select Show Register the Supply HCP Select Work Area and register the firmware by the Machine Administration Menu In this state it is not upgraded yet 4 Do the No 5 7 of above Registration from CD ROM Registration from applying of the ESF patch 1 When the following Patch is offered Patches application is done Patch ID 913034 xx Package name FJSVhcp Patch Name Enhanced Support Facility 2 X Hardware Control Program patch X is 3 or more Patch file name 913034 xx tar Z You can obtain the patches data as follows Download the patch from Our Site and apply patch Apply patch included in the ESF Patches CD ROM When you apply patch by the ESF Patches CD ROM about
351. us of all LEDs is displayed Optional Specify either of the following LED types for Value7 check The command applies to the CHECK LED only all The command applies to all LEDs Jed weet If this option is not specified but the mode or status option is specified the command applies only to the CHECK LED When led is specified be sure to specify either check or all In addition be sure to specify either the mode or status option Optional However if led is specified and this option is not specified be sure to specify the status option This option is used to turn on or off CHECK LED or to cancel control Specify the following one of the following controls for Value2 on Turns on the CHECK LED blink Causes the CHECK LED to blink off Cancels the specified CHECK LED control and restores the CHECK LED to its original state mode Value2 When mode is specified on blink or off must be specified Optional However if led is specified and this option is not specified be sure to specify the mode option status This option enables the status of the LED specified by Value7 to be displayed When led is not specified the status of CHECK LED is displayed Note When the error remains in the server the CHECK LED keeps blinking even if you cancel the specified CHECK LED by this command show status show status command provides fault factors to blink CHECK LED except blinked by nodel
352. ved Copyright C FUJITSU LIMITED 2003 2004 2005 D 1 D 2 Troubleshooting XSCF and FAQ This section describes problems that can occur while XSCF is being used and provides solutions for them In addition FAQ is described Could not log in to XSCF Check whether you used the correct user name and if you use the XSCF Web function check whether the same user name is already logged in Check whether you used the correct password Check the number of XSCF users For the number of users see Chapter2 Setting Up XSCF and Chapter 3 Connecting XSCF to Terminal Forgot login keyword for XSCF Set the keyword again by setting command For the default value of the login keyword see Chapter6 How to Use the XSCF Command Shell Forgot login password for XSCF Set your password again from the Machine Administration Menu Could not connect to XSCF via the serial port Check whether the correct login keyword was used Check whether the terminal software has been connected to the serial port Chech the setting of the terminal software Baud rate 9600bps Delay except for 0 etc For information about the setting see Connecting to XSCF via the serial port tty a in Chapter3 Connecting XSCF or Server Could not connect using telnet to XSCF via the SCF LAN Check whether the SCF LAN settings by the Machine Administration Menu have been enabled Check whether the telnet settings have been enabled by a comma
353. ver error and the location of the Back panel eror SCF Ready LED Indicates the initial state of XSCF Message window Displays a message Figure 4 1 shows the remote Panel All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 4 1 Overview of the Remote Panel ONLINE LED Green POWER LED Green CHECK LED Amber t t Power _ SE Reset switch switch Mode switch slide switch SCF Ready LED Green Request t switch AQ A MAINTENANCE mode LOCK mode UNLOCK mode Check SCF Ready 4 CHECK LED Amber equivalent to the CHECK LED on the front panel Front panel Back panel Figure 4 1 Remote Panel Next 4 2 How to Use the Remote Panel 4 3 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 4 How to Use the Remote Panel 4 2 How to Use the Remote Panel This section explains how to use the remote Panel Before using the remote Panel Before using the remote Panel be sure to specify the following Network settings and Console settings for enabling XSCF User account settings for authentication on the Web http settings for enabling the XSCF Web function The http settings specify the names of hosts to which access is permitted whether the remote panel is to be displayed graphically or in text and whether operations against switches are allowed Note To enable the switch operation specify Enable with read write mode at the optton of XSCF
354. w a sample It might be changed because of the function improvement Next 5 2 Starting the XSCF Web Function All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 5 2 5 2 Starting the XSCF Web Function Starting the XSCF Web Function Prerequisites The initial settings of the XSCF Web function are disabled by default To use XSCF Web function the following must be specified XSCF account IP address of a client terminal XSCF Web function mode Mail report settings Optional but recommended because you can receive a mail from system in case of login failure For details of the above settings see Chapter2 Setting Up XSCF Supported browsers Table 5 2 lists the Web browsers supported by the XSCF Web function Your Web browser needs functions listed in the table below to use the XSCF Web function properly Make sure these settings are enabled Table 5 2 Supported browsers Browser Version Microsoft R Internet Explorer 5 5 6 0 Netscape Communicator TM 4 76 4 78 Netscape Navigator TM 6 2 x 7 0x Functions to be enabled on the browser SSL Secure Sockets Layer Protocol Version 3 TLS Transport Layer Security Version 1 JavaScript Cookies Graphic display capability when graphics mode is used For Microsoft R Internet Explorer go to Advanced tab in Internet Options and uncheck Display a notification about every script error ar WON gt Spec
355. ware error event in the Hardware monitoring information of Machine Administration Menu For the menu see the Machine Administration Guide for the ESF Q8 When the standard console OS console of XSCF is connected via the serial port tty a if you type tilda period it becomes the login window How can make the login window return to the standard console without login Should I wait for several minutes Even if you wait a lot of time you cannot return to the standard console from the login window Please push the Enter key 5 times or more continuously to make the login fail In addition the e mail is sent when the XSCF Mail function is is enabled Q9 What is the relation between the error information of the XSCF error logs and MIB file The error information of MIB file is the newest error log of XSCF D 7 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 D 8 Q10 How to initialize the XSCF Network Configuration Select Network Configuration in XSCF Administration menu of the Machine Administration Menu Please initialize in the following procedures 1 Select IP Address in Network Configuration menu by number 2 Next please set an IP address as a blank And hit a return key 3 Then select Save Configuration in Network Configuration menu and execute it The Initialization of Network Configuration is completed at this time Next D 2 Troubleshooting the Server While XSCF Is Being U
356. wer supply The required authority for this command is root level Next 6 4 XSCF Log View Command All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 6 How to Use the XSCF Command Shell 6 4 6 16 XSCF Log View Command Use the following XSCF commands to check the server operation from console logs temperature history and error logs show error logs show power logs show event logs show console logs show access logs thermal history show device records show ipl logs show panic logs show error logs The show error logs command is used to view the summary of errors or notification that have been detected by XSCF and OBP The log information can be viewed when a system error such as a reset error failed OS startup error indicated by blinking of CHECK LED on the front or back panel of the server or slow down of process on Solaris OS has occurred The same error log information is also retained by the Machine Administration Menu For the logging information retained by the Machine Administration Menu see the Machine Administration Guide for the ESF The maximum The following table explain number of log entries is 32 s the items recorded in error logs Table 6 6 Items displayed by the show error logs command Component Description No indicates the sequence number assigned to the error to be No Error Count displayed ErrorCoun
357. within 15 characters which contain the extension The small letter or the number can be used for the file name It is necessary to contain extension key in the key file name The size of the key file should be the following 1 byte 2048 bytes When the key data are resigtered or deleted it is necessary to invalidate all ports for SSH EXIT STATUS 0 Normal end gt 0 An error occurred SSH Settings Need the several settings for using the SSH function in each functions Standard console Read only console and XSCF shell In addition you have to set whether to use telnet or SSH in each functions by command on the Machine Administration Menu The Explain of the Setting as follows In Console Administration menu of the Machine Administration Menu specify the following It is the same when using telnet Specify LAN port in Select Standard Console Specify Enable in Access Control of Read only Console Specify Enable in Access Control of XSCF remote control For more information of settings see the section Console Administration In the Machine Administration function set the SSH function by using xscf_setssh command When you want to use the SSH function by Standard console Read only console and XSCF 2 37 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Chapter 2 Setting Up XSCF shell in all issue the following command opt FJI
358. wn When power is restored XSCF automatically turns on the power to the server then starts up the OS relieving the administrator of extra work On your decision it is possible to disable automatic power on triggered by power restoration For information about the settings for a power failure see the Machine Administration Guide for the Enhanced Support Facility ESF For more information about the remote panel see Chapter4 How to Use the Remote All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 1 1 XSCF Features Panel Assistance in hot swapping the power supply and fans XSCF provides assistance in hot swapping in conjunction with the Machine Administration Menu For information about the Machine Administration Menu see the Machine Administration Guide for ESF Stronger monitoring functions More powerful monitoring functions monitor among other items fans temperature inside the server and ambient temperature Networking features To provide system independent access to the server XSCF provides networking functions that do the following Monitor the server even when the OS is inactive Enable remote operation of the server Report error messages by e mail to specified addresses Hardware failure log XSCF logs information about hardware failures The XSCF hardware failure log makes it possible to identify the location of a failure The log also provides assistance in anticipating failures on
359. xplanation A shutdown was requested because of power failure The shutdown is informed via SPARC Source 14 Power supply monitoring Detailed code x01000000 Explanation A shutdown was requested because of PSU error Source 14 Power supply monitoring Detailed code x06000000 Explanation A shutdown was requested because of sensor error Source 15 FAN monitoring Detailed code x01000000 Explanation A shutdown was requested because of fan error Source 16 Temperature monitoring Detailed code x01000000 Explanation A shutdown was requested because of CPU temperature error Source 16 Temperature monitoring Detailed code x06000000 Explanation A shutdown was requested because of sensor error 42 Power off Source 00 PANEL SWITCH Detailed code x00000000 Explanation Power off was executed with the switch on the operating panel Source 01 NVRAM TOD Detailed code x00000000 Explanation Power off was executed by the NVRAM TOD timer setting Source 02 RCI IO Detailed code xXX000000 Explanation Power off was executed from RCI IO XX indicates the node number of RCI IO which request the power off to this system Source 03 SYSTEM CONSOLE pl Detailed code x00000000 Explanation Power off was executed from the system console B 67 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 Source 05 CPU Detailed code x00000000 Explanation Power off was executed
360. y the Machine Administration Menu the description is corrected Summary of Changes in Fourth Edition The current fourth edition of this manual differs from previous edition principally by containing the addition of detailed explanations for Firmware Upgrade and the addition of descriptions about information Messages The fourth edition contains minor clarifications and corrections and also the following significant changes relative to the previous edition Chapter 10 XSCF Firmware Upgrade and Dump The detail information of the method of firmware upgrade are added Appendix A Warning And Information Messages In Message Types Other information messages are added Appendix B XSCF Log Information XSCF Error Log List are corrected Error codes 4201010n Notice 8E20F800 and FEOOOOFF are added Error codes 250000FF 4201810n 42040100 42048100 and 8E20FA00 are corrected XSCF Event Log List are corrected Powerlog A definition of x50 is added Appendix C XSCF MIB In Table C 14 Fujitsu extended TRAP Since the contents of MEANING of TRAP TYPE scfHardwareErrorRepair and scfHardwareDefectRepair are reverse they are exchanged Summary of Changes in Third Edition The current third edition of this manual differs from previous edition principally by containing the addition of REMCS agent function and the addition of SSH function for the strengthening of network security The t
361. y low Explanation Low battery voltage was detected Replacement part number 01 SB 00 Action Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830101FF Message INLET thermal low warning Explanation Low inlet temperature was detected Replacement part number FF FF Action Check the installation environment Or Replace the panel For models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF 830104FF Message INLET thermal high warning Explanation High inlet temperature was detected Replacement part number FF FF Action Check the installation environment Or Replace the panel For models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning 3 XSCF B 25 All Rights Reserved Copyright C FUJITSU LIMITED 2003 2004 2005 83020100 Message PANEL FRU data error Explanation An FRU data error in PANEL EEPROM was detected Replacement part number 02 PANEL 00 Action Replace the panel For models 250 R4 250 P 450 R 450 Q Replace the O back panel Or Replace the SB Contact the system administrator or a FE Error level report level error detection source Warning