Home

PPC-HDD(MS) User`s Guide

image

Contents

1. Mitsubishi General purpose Sequencer QCPU Q Mode User s Manual Hardware Design Maintenance and Inspection Device is to be powered by limited Voltage Current circuit of Listed Power Supplies Models Q61P A1 Q61P A2 Q61P Q63P Q64P manufactured by Mitsubishi Electric Corp Fastening the Hard Disk Unit Fit the unit fixing hook in the unit fixing slot in the base unit then push the hard disk unit in the direction of the arrow to set the hard disk unit on the base unit Unit fixing hook After setting the hard disk unit on the base unit be sure to use the attached unit fixing screw to fasten the hard disk unit to the base unit Tighten the screw within the following torque range Tightening torque range 36 to 48N cm If the hard disk unit may be subject to vibration between 4 9 and 9 8 m s use a set of hard disk unit shock proof brackets PPC HBR 01 available as an option For installing the base unit with the hard disk unit on the control panel refer to the manual for the shock proof brackets CONTEC PPC HDD MS PPC HDD MS User s Guide Functions of Components Component Locations Front panel 1 PPC HOD o access O lt Access LED lt Enhanced slave IDE interface connector Buve Internal disk master slave selector switch Set the first and second disk units
2. compatible with the Mitsubishi Programmable Logic Controller MELSEC Q series The drive in the hard disk unit is a 2 5 inch IDE hard disk with a storage capacity of 40 GB For configuration of the system using the hard disk unit and its connection refer to the PPC CPU686 MS user s manual Product Configuration CONTEC PPC HDD MS Unit 1 User s Guide this booklet 1 IDE connection cable 1 Unit fixing screw 1 M3 x 12mm PPC HDD MS User s Guide Specifications Function Specifications Internal drive Transfer rate Max 66 6MB sec Ultra DMA Mode 4 16 6MB sec PIO Mode 4 Reliability 1 10 8bits read lunowbitsread oo Connection to PC CPU Module Extension 40 pin half pitch connector for connecting slave IDE device Capable of connecting one IDE device with master slave selector switch Access indicator 2 High temperature detection Ambient temperature detected 47 3 C or higher Warning method High temperature detection function of bus interface driver software External dimensions mm Power consumption Weight Average life 3 1 1GB 1 000 000 000bytes 2 When two disk units hard disk and or silicon disk units are connected in a master slave arrangement they have common access indication When either of the master and slave devices is accessed therefore both of their access lamps come on at the same time 3 Under the assumptions Less than 333 power on hours per month And Seeking W
3. as the master and slave devices respectively s M lt When only one disk unit is used set it as the master device ye Factory default M Master device Bottom Front co Ce Ce Es al Ce pana D D D E IDE interface connector D For connection to the PC CPU Module D mmp D Rear Ge For the pin assignments in the IDE interface and Enhanced IDE interface connectors refer to the user s manual for the PC CPU Module CONTEC PPC HDD MS 6 PPC HDD MS User s Guide Master Slave Arrangement PPC HDD MS or PPC SDD MS xx Disk unit Master Slave PPC CPU686 MS PC CPU Module ee ele oO rele 0 0 Connect the master and slave disk units with an IDE connection cable t Set this to Slave S Set this to Master M Connect the PC CPU Module to the master disk unit with an IDE connection cable Note Setting the silicon disk unit as the master device involves a restrictions For details refer to the manual for the silicon disk unit To use the hard disk unit along with the dedicated CD ROM drive IPC CDD 02 in a master slave arrangement refer to the manual for the dedicated CD ROM drive Average Life of the Hard Disk Drive The average life of the hard disk drive is 5 years or 20 000 hours of energized time whichever reached first High temperature Detection
4. Feature Using the hard disk unit in a high temperature environment shortens the life of the hard disk The hard disk unit has a high temperature detection feature to detect an ambient operating temperature of 4743 C or higher using the high temperature detection function of bus interface driver software Use this feature as a means of warning when the hard disk unit is being used at high temperature When high temperature detection is not necessary you can disable the high temperature detection function by setting with the bus interface driver software In that case high temperature detection is not performed For details on this function refer to the Bus Interface Driver User s Manual PPC CPU686 MS MU separately priced CONTEC PPC HDD MS PPC HDD MS User s Guide Copyright 2003 CONTEC CO LTD ALL RIGHTS RESERVED CONTEC CO LTD February 2008 Edition 3 9 31 Himesato Nishiyodogawa ku Osaka 555 0025 Japan Japanese http www contec co jp English _ http www contec com A 46 789 LYCY753 Chinese _ http www contec com cn 02222008_rev5 07252003 No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD
5. Hard Disk Unit for PC CPU Module Compatible with MELSEC Q Series PPC HDD MS User s Guide CONTEC CO LTD Thank you for purchasing the PPC HDD MS hard disk unit for PC CPU Module Follow the instructions in this guide to use the product Notes The hard disk drive can be easily damaged by electrostatic discharge ESD Use meticulous care in handling the hard disk unit for moving or assembling When using the hard disk unit be sure to satisfy the conditions listed as its general specifications For use in a severe environment use the silicon disk unit instead For use in a place subject to vibration or shock use a set of shock proof brackets PPC HBR 0O1 available as an option As the hard disk unit has a limited life be sure to back up important data recorded on the unit To back up the contents of the hard disk including the OS you should use a commercial backup tool such as Symantec Ghost The hard disk drive HDD of this disk unit has not guaranteed use by continuation and continuation power for 24 hours When it is used by continuation operation and continuation power a life falls extremely In the case of a 24 hour operation system use of our company silicon disk SDD is recommended The life of a hard disk drive changes with environment or operating conditions As a standard power time motor on time below 333hours month below 11 hours day disk access time is 20 or less it becomes which for 20 000 hours pow
6. ated in the operating environment Pollution level 2 indicates the environment that generates only nonconductive pollutants while allowing accidental condensation to cause temporary conduction 3 The hard disk unit may fail and cannot be used in an environment in which the air is compressed to over the atmospheric pressure generated at an altitude of around 0 m External Dimensions Enhanced IDE interface connector 130 27 4 4 je a er PPC HOD access D BUDE so YOE N IDE interface connector For connection to the PC CPU Module Related Options PPC SDD MS Series IPC CDD 02 PPC HBR O1 PPC CPU686 MS MU C4 UUUUUNUUUU0000000 MUUUUUNNUU00000000 D mm Silicon disk unit CD ROM DVD ROM drive Hard disk unit shock proof brackets A set of upper and lower brackets User s Manual PC CPU Module User s Manual Bus Interface Driver User s Manual CONTEC PPC HDD MS PPC HDD MS User s Guide Installing the Hardware Precautions Install the hard disk unit on the MELSEC Q Series base unit before it can be used Before using the hard disk unit be sure to mount the MELSEC Q Series base unit on the control panel using screws Do not use the base unit mounted on the DIN rail For mounting the base unit refer to the
7. er time or five years or an early thing Do not touch the interface connector of the hard disk unit Before plugging to or unplugging from the connector on the hard disk unit be sure to turn off the power unit CONTEC assumes no liability for any loss or destruction of data recorded by this product regardless of the attribute of the causing fault or failure Be sure to back up important data Copyright Copyright 2003 CONTEC CO LTD ALL RIGHTS RESERVED No part of this document may be copied or reproduced in any form or by any means without prior written consent of CONTEC CO LTD CONTEC CO LTD makes no commitment to update or keep current the information contained in this document The information in this document is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify CONTEC CO LTD CONTEC PPC HDD MS PPC HDD MS User s Guide Regardless of the foregoing statement CONTEC assumes no responsibility for any errors that may appear in this document or for any results of using the product Trademarks MELSEC and CC Link are registered trademarks of Mitsubishi Electric Corporation All other brand and product names are trademarks of their respective holders About the PPC HDD MS This product is the hard disk unit dedicated to the PC CPU Module PPC CPU686 MS
8. riting Reading operation is less than 20 of power on hours General Specifications Specification 8 to 90 RH No condensation 5 to 95 RH No condensation Maximum wet bulb temperature 29 C Vibration resistance Tested 10 times for 45 minutes in each of the X Y and Z directions in during operation conformance with JIS C0040 0 to 55 Hz 0 035 mm lt With the optional hard disk unit fixing brackets attached gt Tested 10 times for 80 minutes in each of the X Y and Z directions in conformance with JIS C0040 0 to 57 Hz 0 075 mm 57 to 150 Hz 9 8 m s Shock resistance during operation _ Tested 3 times in each of the X Y and Z directions in conformance with JIS C0041 49 m s 11 ms Operating ambiance No corrosive gas Operating altitude 2000 m or less 3 Installation location Inside the control panel Do not install the base unit on the DIN rail when the hard disk unit is used Over voltage category 1 II or lower Pollution degree 2 2 or less 1 The overvoltage category of a device indicates which distributor in the range from public distribution network to machinery the device is assumed to be connected to Category II applies to devices to which power is supplied from fixed facilities The surge voltage of those devices is 2500 V whose rated voltage is 300 V CONTEC PPC HDD MS PPC HDD MS User s Guide 2 The index indicating the degree to which conductive substances are gener

Download Pdf Manuals

image

Related Search

Related Contents

Applica CI-1A User's Manual  Samsung SP-H03 Uživatelská přiručka  「医見書」 ソフ トの改正対応について  Samsung DVW-707/707P User's Manual  01-14.indd  BoConcept Model 280 Assembly Instruction  Mode d`emploi casserole à pression/autocuiseur  StecaGrid 8 000+ 3ph StecaGrid 10 000+ 3ph  P - Kälte Berlin  取扱説明書 - 日立の家電品  