Home
User Manual
Contents
1. Q Relief At Last User Manual For an effective treatment read the entire User Manual before using Kyrobak r Know Your Kyrobak 2 Safety Instructions 3 Before You Start 4 How to Use Kyrobak 5 Operating Your Kyrobak 10 Troubleshooting 12 Contents Q D xX Technical Specifications 13 Know Your Kyrobak Kyrobak is a revolutionary home use device clinically proven to treat non specific lower back pain using Continuous Passive Motion CPM This non invasive gentle approach provides you with a simple relaxing method to treat your pain All you need is 10 minutes a day Lie back relax and leave the rest to Kyrobak What s Included Kyrobak Device Power Supply Device Features Cushion Power Supply Connection On Off Treatment Speed Button safety Instructions Warnings e Do not use without clothing e Do not use in a wet or damp place e Do not use on a moving surface like a waterbed e Do not cover yourself with a blanket or any other cover during treatment e Keep your hands away from all moving parts during treatment e Keep out of reach of children e Do not stand or jump on the device Only use this device for its intended purpose and as described in this User Manual e Do not smoke during treatment e Do not eat or drink during treatment Cautions e Do not reach for a device that has fallen into water while it is
2. Your buttocks are positioned in the center of the Cushion 2 Lie Down Make sure Your buttocks are positioned in the center of the Cushion Your body is straight without slanting to one side or the other Your back and upper body are on the floor Correct Pelvic Position Incorrect Pelvic Position X INCORRECT X INCORRECT How to Use Kyrobak Leg Position Your legs can be positioned in two ways Position 1 Legs bent at a 30 to 45 angle with the feet flat on the floor Position 2 Legs elevated on a chair with the thighs at a 90 angle from the floor Correct Arm Position Arm Position Position your arms loosely at your sides at a 30 to 45 angle from your body Do not touch the device with KA your arms or hands Head and Neck Support If you feel discomfort in your head or neck place a small soft pillow under your neck and head Remember to keep your body straight with your hands at your sides 10 Operating Your Kyrobak 1 Turn the Device On Press the On Off Button until the device begins to gently rotate a 2 Set the Treatment Speed Set the desired speed by pressing the On Off button after the Unit has turned on b e The default speed is Low e Push the On Off button again to go Medium e Push the On Off button again to go to High One more push of the button will return the device to the default setting of Low The first time you use
3. listed in this User Manual Radiancy is responsible for the effects on safety reliability and performance of the equipment only if repairs are carried out by Radiancy authorized personnel Radiancy Inc 40 Ramland Road South Suite 200 Orangeburg NY 10962 USA 1 888 661 2220 1 845 398 1647 Customer Support 888 998 4713 International Standards Electrical Safety Power Supply double insulation This appliance is not suitable for use in the presence of flammable anesthetic mixture with air or with Oxygen or Nitrous Oxide The Quality Management System of Radiancy Ltd complies with the Quality Management Standard EN ISO 13485 Kyrobak complies with the following international standards and directives General Requirements for Basic Safety and Essential Performance 3rd Ed IEC60601 1 2005 EN60601 1 2006 Electromagnetic Compatibility IEC 60601 1 2 2007 Electromagnetic Compatibility Kyrobak requires special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this document FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause interference to radio communications These limits are designed t
4. Kyrobak stay at least one minute on each speed before going to the next Stay at the speed that is most comfortable for you The next time you use Kyrobak you can start at the last speed used during your previous treatment When you are finished unplug Kyrobak and store it in a safe dry place away from children and pets 3 Begin Treatment With your arms at your side at a 30 to 45 angle from the body lie back and relax You will feel gentle continuous movement in your pelvis area If at any point during the treatment you feel your body shifting to one side of the device you should realign your pelvis to the center of the Cushion and continue the treatment After 10 minutes the treatment will automatically stop and the device will shut down To stop the treatment for any reason hold down the On Off button until the device stops moving and turns off 4 End Treatment When the treatment is complete and Kyrobak stops moving it is recommended to relax for one or two minutes before getting up To get up gently roll onto one side c and then using your elbows as support push yourself into a sitting position and stand up d 11 12 Important e Positioning yourself correctly on the device is the key to an effective treatment e Kyrobak uses a very gentle movement on the lower back This gentle movement is clinically proven to alleviate lower back pain Kyrobak treats lower back pain and provides
5. a lasting effect However you may not feel an immediate alleviation of pain right after the first time you use Kyrobak The more you use the device the more relief you should experience Troubleshooting If Kyrobak does not start e Disconnect the Power Supply from both ends wait 2 minutes plug it in and try again e Make sure the cable is connected securely to the device e Make sure the Power Supply is connected securely to the electrical outlet Make sure the electrical outlet is working properly e Press the On Off button down for an extended time until the unit turns on e In rare cases the On Off button will appear to be blinking when the device is turned on This is an indication that the device is faulty and that customer service should be contacted Product Labels amp Symbols This section describes the labels affixed to the Kyrobak and found in the user manual It is recommended that users review the meaning of these labels for everyday usage and in case any details are needed for service The table below briefly reviews a number of the internationally recognized symbols that are found on the Kyrobak main Unit and its external package Weight 3 15 kg Physical Dimensions 12 x 45 x 39 cm w d h Technical Specifications Label Explanation RADIANCY Model kyrobak SUB 00243 CREF MUN AMR ad MUN Located at the bottom of the device Indicates the need to consult instructions for
6. age dips short 40 UT 60 dip in UT ee intenuptions and voltage fp lt 5 UT 40 UT 60 dip in UT Mains power quality should be that of a typical public low voltage power supply network that variations on power supply y j for 5 cycles lt 5 UT supplies buildings used for domestic purposes commercial or hospital Environment input lines 70 UT 30 dip in UT 70 UT 30 dip in UT If the user of the Kyrobak requires continued operation during power mains interruptions it is i may for 25 cycles lt 5 UT recommended that Kyrobak be powered from an uninterruptible power Supply or a battery IEC 61000 4 11 for 25 cycles lt 5 UT lt 5 UT gt 95 Ydip in UT lt 5 UT 695 dipin UT for5s for5s Power frequency 60 60 Power frequency magnetic fields should be at levels characteristic of a typical public Hz magnetic field IEC 3 A m 3 A m low voltage power supply network that supplies buildings used for domestic purposes commercial or hospital Environment NOTE UT is the a c mains voltage prior to application of the test level 15 LEIGE Guidance and manufacturer s declaration electromagnetic immunity Kyrobak The Kyrobak is intended for use in the electromagnetic environment specified below The customer or the user of the Kyrobak should assure that it is used in such an environment Immunity test Eo ie Compliance level Electromagnetic environment guidance Test level Portable and mobile RF communic
7. ations equipment should be used no closer to any part of the Kyrobak including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Conducted RF 3 Vrms d 1 17yP d 1 17 P 80MHzto800 MHz IEC 61000 4 6 150k Hzto 80 MHz 3 Vms d 234 P 800 MHz to 2 5 GHz Radiated RF AUM S Vm where P is the maximum output power rating of the transmitter in watts W according to the transmitter IEC 61000 4 3 80 MHz to 2 5 GHz manufacturer and d is the recommended separation Distance in meters m Field strengths from fixed R F transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range d Interference may occur in t he vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in t
8. he location in which the Kyrobak is used exceeds the applicable RF compliance level above the Kyrobak should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the Kyrobak b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Ele lt a Recommended separation distances between portable and mobile RF communications equipment and the Kyrobak The Kyrobak is intended f or us e in an electromagnetic environment in which radiated RF disturbances are Controlled The customer or the user of t Kyrobak can help prevent electromagnetic interference by maintaining a minimum distance between port able and m obi le RF communications equipment transmitters and the Kyrobak as recommended below according t o the maximum out put power of t he communications equipment Separation distance according to frequency of transmitter Rated maximum Meters m output power of transmitter Watts W 150kHz to 80MHz 80MHz to 800MHz 800MHz to 2 5GHz d 1 17 P d 1 17 P d 2 34 P 0 01 0 12 0 12 0 24 0 1 0 37 0 37 0 74 1 1 17 1 17 2 34 10 3 7 3 7 7 4 100 11 7 11 7 23 4 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum o
9. o provide reasonable protection against harmful interference in a residential installation Notice The FCC regulations provide that changes or modifications not expressly approved by Radiancy Inc could void your authority to operate this equipment ual Manufacturer Radiancy Israel Ltd 5 Hanagar Street 4527708 Hod Hasharon Israel European Representitive Obelis s a Bd G n ral Wahis 53 B 1030 Brussels Belgium Phone 32 2 732 59 54 Fax 32 2 732 60 03 E mail mail obelis net Manufacturer s declaration for electromagnetic compatibility EMC for the Kyrobak according to EN 60601 1 2 2007 Tables 1 2 4 and 6 Table 1 emissions Kyrobak Guidance and manufacturer s declaration electromagnetic The Kyrobak is intended for use in the electromagnetic environment specified below The customer or the user of the Kyrobak should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions The Kyrobak uses RF energy only for its internal function Therefore its RF emissions CISPR 11 Group 1 are very low and are not likely to cause any interference in nearby electronic equipment RF emissions Class B CISPR 11 The Kyrobak is suitable for Hamonig use in all establishments missiohs lass A including domestic IEC 61000 3 2 establishments and those directly connected to the Voltage public low voltage power fl
10. plugged in e Unplug the Power Supply from the main source of power before removing it from the water e Do not place or store this device near water or other liquids e This device should never be left unattended while plugged in e Keep the area around the Power Supply clear with nothing on or underneath it e Do not use the Power Supply if the cord or plug is damaged in any way e Do not use this device near or rest it on flammable objects such as paper or cloth etc Always unplug the Power Supply from the electrical outlet immediately after use e This device should only be used with the supplied Power Supply e Always turn off this device when you have finished using it e Do not open the outer casing of the Unit This might harm the Unit and will void any warranty Before You Start Kyrobak Is only for people who suffer from non specific lower back pain If you have been diagnosed with or have any of the following conditions this product is not for you Contraindications DO NOT USE f you have had any back surgery including spinal fusion f you have acute Lower Back Pain LBP f you have Listhesis Spinal misalignment of grade II and above f you have orthostatic hypotension dizziness upon standing suddenly f you have irradiating pain to the leg s f you have a slipped disc f there is central pressure on the spinal cord that results in the following s
11. uctuations supply network that supplies flicker Complies buildings used for domestic emissions purposes IEC 61000 3 3 LEL CEA Guidance and manufacturer s declaration electromagnetic immunity Kyrobak The Kyrobak is intended for use in the electromagnetic environment specified below The customer or the user of the Kyrobak should assure that it is used in such an environment 61000 4 8 IEC 60601 1 2 Immunity test Test level Compliance level Electromagnetic environment guidance ae 6 kV contact 6 kV contact Floors should be wood concrete or Ceramic tile If floors are covered with synthetic material i i 1 idi 0 IEC 61000 4 2 8 kV air 8 kV air the relative humidity Should be at least 30 Electrical fast transient burst 2 KV for power supply lines 2 kV for power supply lines Mains power quality should be that of a typical public low voltage power supply network that IEC 61000 4 4 1 KV for input output lines Not Applicable supplies buildings used for domestic purposes commercial or hospital Environment Surge 1 kV differential mode 1 kV differential mode Mains power quality should be that of a typical public low voltage power supply network that IEC 61000 4 5 2 kV common mode 2 kV common mode supplies buildings used for domestic purposes commercial or hospital Environment lt 5 UT gt 95 Ydip in UT for 0 5 cycle lt 5 UT gt 95 Ydip in UT for 0 5 cycle Volt
12. use Manufacturer Indicates the Authorized Representative in the European Community Indicates the temperature limitation Degree of protection against electric shock Type BF applied part CE mark represents the compliance to the European Low Voltage Directive 2006 95 EC and the Electromagnetic Compatibility Directive 2004 108 EC Protect the environment by not disposing of this product with household waste 2002 96 EC Check your local authority for recycling advice and facilities Europe only Catalogue Number Indicates the manufacturers catalogue number so that the device can be identified Serial Number Indicates he manufacturers serial number so that a specific device can be identified C9 The package may be recycled IP21 IP21 according to IEC60529 Degrees of Protection Provided by Enclosures IP Code Technical Specifications Treatment 40 minutes Time ae s Internally Powered CESSION Equipment Type BF Mode of l Continuous Operation and Temperature 25 C to 70 C Da A Conditions Humidity 0 93 RH Electrical 9 12Vdc 3A Max from an AC DC adaptor In Requirements 100 240Vac 50 60Hz 71 99VA 0 9A Temperature 5 C i 40 C Operating Humidity 15 93 RH Conditions Atmospheric 700 hPa to 1060 hPa pressure 13 14 Service Centers You are allowed to perform only the servicing
13. utput power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people For videos and tips on how to use Kyrobak visit our website at www How loKyro com For further assistance contact our customer support 888 998 4713 LIT 00179 Rev A 01 Oct 2013
14. ymptoms urinary problems numbness in both legs and or loss of balance f you have systemic rheumatic disorders i e rheumatoid arthritis lupus f you have hip or knee symptomatic osteoarthritis f you are unable to get up from the floor without help f you have psychiatric disorders f you are under 18 f you are pregnant f you weigh over 120 kg 265 Ibs Please consult a physician before using Kyrobak f you are suffering from low back pain with evidence of underlying disease or abnormalities f your back pain is induced by a recognized suspected or impending fracture f you suffer from any form of developing or new neurological deficit How to Use Kyrobak 1 Connect power supply into the Kyrobak unit 2 Plug power supply into a household outlet Getting Started e Wear comfortable clothing that covers your lower back Set up in a quiet place close to a power outlet with enough room to lie down comfortably e Place Kyrobak on the floor bed couch or any other smooth flat surface When using the device on the floor you can place it on a rug or mat Treatment Regimen We recommend you use Kyrobak for one 10 minute treatment per day You can use it up to 3 times a day but wait at least 4 6 hours between each treatment an effective treatment 1 Carefully Sit in the Center of the Cushion Make sure Your legs are facing the cylinder shaped side of the device