1. Filter control Heating Solar Backwash System Figure 10 Menu function Solar If the menu function Solar appears in the display this can be selected by pressing the OK key AS Control manual version 09 2012 Page 7 The temperature setting can be checked The set value can be changed by pressing the OK key Setting range Temp Opt gt Temp Min So always set the optimum temperature higher than the minimum temperature The temperature starts blinking and can be changed using the arrow keys Press the OK key again to save the changed value Press the Mode key if no changes are required The old value will remain unchanged Attention Temperatures gt 28 C can damage parts of the swimming pool or the swimming pool technique and or shorten its life span Remark The temperature data are indicative Minor deviations 2 C are possible Backwash The installer can enable this function in the Configuration menu With this function you can control an Besgo backwash valve The backwash and clearwash cycles can be set through this menu The corresponding magnetic valves are connected in the switch box Test Man Reset BwCw in days 1 Pauze Off Clearwash 0 5 min Backwash 3 min Starttime 09 00 Interv Days 01 Filter control Heating Solar Backwash System Mode 4 ok
2. Figure 1 Operation of the control cabinet With the Filter key you can switch the operation of the filter pump In the OFF position all components filter heating and solar energy are disabled In the On position the filter pump is running continuously In the Automatic position the filter running time s is are in accordance with the set switch times The Heating key enables or disables the heating control If a switch has been made there will be no reaction to changes or new switches during the set lagging time Hysteresis in the Configuration menu The LED will blink AS Control manual version 09 2012 Page 2 Remark This function cannot be enabled when the water sensor is defective or has not been connected The Solar key enables or disables the operation of the solar energy heating control Remark This function cannot be enabled when the water sensor solar sensor is defective or has not been connected Here no reaction will follow changes or switches during the lagging time after a switch The LED will blink Display of the operation conditions Operation Filtering Pump failure Temperature reached Heating Solar heating Solar cooling Frost danger Settings in the display The LED is lit when the mains power supply has been connected The LED is lit when the pump has been switched on The LED is lit when the filter pump motor safety has been switched off This LED is lit when the set requ
3. Figure 11 Menu function Backwash If the menu function Backwash appears in the display this can be selected by pressing the OK key The set values can be checked and they can be changed by pressing the OK key Interv Days 01 This interval indicates the number of days that is between the starting of the backwash cycle For example 10 days This means that the backwash cycle is carried out every 10 days The possible intervals are OFF 30 days OFF disables the backwash program Starting time 09 00 In this menu you can enter the starting time for the backwash cycle AS Control manual version 09 2012 Page 8 Remark The backwash cycle must be within the programmed filter times If you want to program something else the message error will appear in the display Backwash 3 min In this menu the backwash time is programmed The possible intervals are O 30 min Clearwash 0 5 min In this menu the clearwash cycle is programmed by setting the clearwash time The possible intervals are OFF 5 min The OFF setting disables the clearwash cycle The Clearwash time cannot be set from the OFF position Pause The backwash and clearwash cycles include three pauses These look as follows Filtering Pause Backwash Pause Clearwash Pause Filtering Here all three pauses are of the same duration However the duration of the pauses can be set The possible intervals are OFF 10 min The OFF setting disables the p
4. Idsip Page 14 AS Control manual version 09 2012 AS Control manual version 09 2012 Page 15
5. Switch time 2 Switch time 1 Filter control Heating Solar Backwash System Mode Figure 5 Menu function Filter control If the menu function Filter control appears in the display this can be selected by pressing the OK key The arrow keys are used for selecting switch time 1 or switch time 2 Pressing the OK key again selects the respective function OK Stop WE12 00 Switch time 1 Start WE09 00 Figure 6 Menu function Switch time With the arrow keys you can check the switch on or switch off times You can change the displayed values by pressing the OK key The time display starts blinking and can be changed using the arrow keys Press the OK key again to save the changed value Press the Mode key if no changes are 4 y required The old value will remain unchanged AS Control manual version 09 2012 Page 5 Remark If the start and end of a switch time have the same value this setting will not be carried out Example Switch time 1 start 9 00 hours end 9 00 hours Remark If switch time 1 and switch time 2 are overlapping the filter pump will run continuously until both running times cycles have been completed Example Filter running time 8 00 hours 16 00 hours Switch time 2 12 00 hour 16 00 hour 08 00 hour 12 30 hour
6. Switch time 1 Figure 7 Filter running time The hour display starts blinking and can be changed using the arrow keys Press the OK key again to save the changed value The minutes display will start blinking now This can be changed using the arrow keys as well Press the OK key again to save the changed value Press the Mode key if you want to stop The old value will remain unchanged Motor safety An adjustable 0 7 9 9 A motor safety protects the three phase or the alternate current filter pump against overload damage When using a pump with a higher power consumption apply an external relay with motor safety switch Current 1 0 A Remark The motor safety must be set before putting the control into operation The consumed current nominal z current of the filter pump is to be measured and checked in Adjust a loaded condition Overload protect Figure 8 Menu function Motor safety The value for the nominal current can be found on the type plate of the filter pump Remark NEVER set the set nominal current higher than 10 of the current strength mentioned on the type plate The LED Pump failure lights up when the motor safety is activated After having remedied the failure you can switch on the system again using the Filter key You can also have the AS Control set the motor current automatically If this option is not selected you will have to manually switch on the filter pump Validate the value using th
7. or other applications If a pump failure takes place or in case of a risk of frost the potential free safety contact will come in This can switch off an external alarm When the filter pump is running the potential free filter contact has been activated as well This can be used for an application that is running parallel to the filter pump AS Control manual version 09 2012 Page 11 If the solar sensor has not been connected the indication in the display will not be present either The AS Control has been secured on all outputs by means of fuses These fuses are to be found below the operating front If a fuse needs replacement insert the correct value in order to guarantee safety The values are as follows F2 0 16 A inert primary F6 3 15 A inert dosing F3 10 A inert R pump F7 3 15 A inert backwash F4 10 A inert s pump F8 3 15 A inert solar F5 10 A inert T pump F9 3 15 A inert heater The printed circuit board does not include any other settings or adjustments points subject to service Terminals Terminals 1 2 3 4 5 are for connecting the mains voltage 1 is the ground 2 is the zero 3 is the first phase R 4 is the second phase S and 5 is the third phase T If no high voltage current is used the power supply is connected to terminal 1 2 3 or the ground zero and the first phase Terminals 6 7 8 9 10 are for connecting the filter pump Terminal 6 is the ground terminal 7
8. well Please keep in mind that the connection SOLAR is cancelled when enabling the backwash menu as this will become the connection for the backwash valve The backwash valve is connected to the terminals 15 16 and 17 whereas the clearwash valve is connected to the terminals SOLAR 22 phase and 23 zero When using a backwash automat the Backwash menu can be disabled The control will then be done by the valve The automat is connected to the terminals 15 16 and 17 power supply for the valve and the filter pump is controlled on the Safety switches terminals 27 and 28 open contact Hysteresis This value can be set between 0 and 9 5 minutes This value determines the lagging time of the filter pump when the end of the filter time has been reached and the heating is still active This time is also used for absorbing temperature fluctuations at switching on Heating or Solar No attention will be paid to temperature fluctuations during the set time as this has been made visible through the blinking LED of the switch this also prevents so called pendulum of the solar control or heating Some instructions for general use If the AS Control is connected to 230 V terminals N and R are to be used Correspondingly the 230V filter pump on N and R of the corresponding terminal block is used as well If the heating is active the potential free heater contact will come in This can be useful when controlling a central heating system
9. AS Control Operation Filtering Pump failure Off On Automatic Heating Temp reached Off Solar heating On A A 4 Solar cooling Off On Frost danger Article number 081037 INSTALLATION AND USER MANUAL What is the AS Control The AS Control is a complete filtering heating and solar energy control for swimming pools Read the entire manual before connecting the AS Control and putting it into operation Operation of the control cabinet General The AS Control has been developed for controlling swimming pool systems The set pool temperature is continuously monitored during the set filter running time s by operating the heating source or not Additionally the control can be provided with an optional solar energy control Various components have by default been included in the control cabinet for this A control program for Besgo backwash valves takes care of backwashing and clearwashing the filter system in accordance with pre programmed times Besides connecting options for dosing technique and surge tank control are present The manufacturer will not accept any guarantee claimyliability in any way for other applications or areas of use than mentioned above Display for filter and heating system and solar energy control The control cabinet is operated by means of individual push buttons Off Filter On Automatic Heating Off Solar Off On
10. auses BwCw in days 1 This menu item indicates when the next backwash clearwash cycle will be started Remark The day counter will be updated every day at midnight Test Man RESET In this menu item you can manually enable the backwash cycle and reset the day counter as well The manual backwashing starts after expiration of a full minute The remaining waiting time can be read from the display Remark The display of the day counter will be updated at midnight System Setting the current time Thanks to a battery the set time will be saved in the system even after a power failure Bear in mind that time is limited here The summer winter time must be adjusted manually Winter OFF Recall Default Set Default Language English Configuration Time WE12 45 Filter control Heating Solar Backwash System Mode 4 ok Figure 12 Menu function System AS Control manual version 09 2012 Page 9 If the menu function System appears in the display the current time can be selected by pressing the OK key The set time can be checked This displayed time can be changed after having pressed the OK key The language shown in the display can be selected here as well by means of the Language setting Electric connection building in and installation of electric devices should only be carried out by authorised
11. e OK key after the measurement AS Control manual version 09 2012 Page 6 Heating The minimum water temperature of the basin is always monitored and maintained when the conventional heating has been connected and or is working because this source of energy is always available contrary to the weather dependent solar energy system Temp Min 20 C Filter control Heating Solar Backwash System Mode y ok Figure 9 Menu function Heating If the menu function Heating appears in the display this can be selected by pressing the OK key The set temperature can be checked and the value can be changed by pressing the OK key Setting range Temp min lt Temp Opt So always set this minimum temperature below the optimum temperature The temperature starts blinking and the set temperature can be changed using the arrow keys Press the OK key again to save the changed value Press the Mode key if no changes are required The old value will remain unchanged Attention Temperatures of gt 28 C can damage parts of the swimming pool or the swimming pool technique and or shorten its life span Remark The temperature data are indicative Minor deviations 2 C are possible Solar The optimum basin water temperature Temp opt can be reached with a connected working solar energy system when the weather conditions allow for this Temp opt 28 C
12. ed to the MOTOR VALVE terminals Terminal 41 is open 42 is Gnd 43 is closed The dosing equipment output 220 240 V AC max 2 0 A is connected to the DOSE terminals and it is active when the filter pump has been switched on Use an extra auxiliary relay for more switching power The backwash automat output 220 240 V AC max 2 0 A WASH always sends out 220 V AC when the LED On or Auto of the Filter key is lit Attention Only connect potential free switch contacts to the inputs of the SAFETY SWITCHES terminals Do not connect live wires cables The TXD and RXD connections are intended for an external operating panel or an external display Some settings are not accessible by default only to the installer AS Control manual version 09 2012 Page 10 The At solar can be adjusted in the Configuration menu This is set to 3 C by default The setting means that the set value is the bottom limit for putting the solar system into operation provided that the solar option has been enabled The value can be set between 3 C and 10 C With Water sensor you can correct a minor deviation of the water sensor maximum and 590 With Solar sensor you can correct a minor deviation of the solar sensor maximum and 590 Serial number this is for the information of the supplier Backwash When selecting this function Backwash will appear in the main menu see the Backwash section When this function is disabled the menu will disappear as
13. ired pool temperature has been reached The LED is lit when the conventional heating has been switched on The LED is lit when the solar energy control has been switched on This LED is lit when the temperature is exceeded with solar energy option The connected solar energy control will cool the basin water if the solar collector s allow s for this Enabled at outside temperatures that have been pre set in the Configuration menu 0 5 degrees If the outside temperature rises again this display will be lit as an indication of a possible threat of the solar energy system You can acknowledge and reset this alarm by pressing the OK key The function can also be disabled in the Configuration menu The Mode key the arrow keys and the OK key are used for menu control in the display Mode OK y Figure 2 Menu control display AS Control manual version 09 2012 Page 3 After having switched on the control the display will show the current time and date as well as the temperature in the basin and the solar temperature For example WE12 34 W28 S24C Figure 3 Current time and temperature display Pressing the Mode key will take you to the menu for setting the filter running times the heating and solar energy control the backwash cycle and the system settings By pressing the Mode key again the display will return to the current time and the swimming pool tempe
14. is the zero and terminals 8 9 10 are the 3 phases Terminals 6 7 8 are used when using a single phase pump They are the ground zero and the first phase respectively The zero is not used with a 3 phase pump Terminals 11 12 13 are the contacts for the dosing equipment terminal 11 is the ground 12 is the phase and 13 is the zero Terminals 14 15 16 17 are for connecting the backwash valves Terminal 14 is the ground 15 is the phase that comes in at a backwash action terminal 16 is a permanent phase for any power supply from a backwash automat terminal 17 is the zero This means that when use is made of a Besgo valve terminals 14 15 17 are used Terminals 18 19 20 are extra connections of a supply voltage for example to empower the potential free contacts The terminals are permanently live 18 is the ground 19 is the phase and 20 is the zero Terminals 21 22 23 are for connecting a solar valve or solar pump Terminal 21 is the ground 22 is the phase and 23 is the zero These terminals are activated when the Backwash function has been enabled for another function in the Systeny Configuration menu In this case terminal 21 is the ground 22 is the phase for the CLEARWASH valve Besgo and terminal 23 is the zero Terminals 24 25 40 ATTENTION TERMINAL 40 IS ON THE HIGHER TERMI NAL STRIP Terminal 24 is the ground 25 is the zero and 40 is the phase for the heating valve or the relay that switches on the heati
15. ng Terminal 26 is an extra ground connection AS Control manual version 09 2012 Page 12 Terminals 27 28 form an interconnection that can be used to stop the filter pump The pump will stop when the connection is interrupted These terminals are potential free and they are usually used for e g a backwash valve or a surge tank control Terminals 29 30 are equal to terminals 27 and 28 for connecting a backwash valve and a surge tank control Terminals 31 32 form a potential free connection used for forced activation of the filter pump This connection is required for connecting a surge tank control Usually this connection is NOT present Terminal 33 is an extra ground for example to protect the water and solar sensors Terminals 34 35 are potential free contacts used for switching on external equipment that must work simultaneously with the filter pump The contact is activated after the filter pump has been operated Terminals 36 37 are potential free contacts used for switching on or signalling heating The contact will be closed when the heating is activated this contact is often used for direct control of a central heating boiler Terminals 38 39 are potential free contacts that may be used for paying more attention to an alarm condition The contact is closed in case of alarm It can control a telephone alarm or a signalling lamp siren etc Terminal 40 see terminal 24 25 heater Terminals 41 42 43 are 24 V AC
16. outputs for controlling a motor valve of the solar system 41 is the closing control 42 is the Gnd 0 43 is the opening control Terminals 44 45 46 these contacts are for connecting an external display Only digital data are transmitted through these contacts Terminal 44 is TXD terminal 45 RXD and terminal 46 is Gnd 0 Terminals 47 48 are for connecting the water sensor if necessary terminal 46 can be combined with 47 as well Terminals 48 49 the solar sensor is connected to these contacts if a solar system is used Terminal 48 can be used as a joint Gnd for both the water and the solar sensors The connection diagram will be shown on the next page AS Control manual version 09 2012 Page 13 Gy g 1 12105 3811 asny 64 b gt z Sel asnj Jejos 84 ejal BunesH T 9811 JOJ93UUOD ysempeg 4 ZA Aejas a9 14 enuajod 1914 1ojo uuoo asny Buisoq 94 gy asny S4 1ojo uuoo s asnj 4 9y y asny 4 asnj 01009 Z4 wo zxew O Z Xew VOZ xew VOZ Xew A 00p A 082 A 082 A082 082 082 S L A 02 uoyoauuos sig ysem juauwdinba 5 1984 Ielu lod seyayws Aayes
17. people in accordance with the local regulations Attention In the Off position s of Filter Heating and Solar not all terminals in the connection compartment are potential free Disconnect switch off the supply voltage of the AS Control in order to protect the system against unintended switching on Attention Disconnect switch off the supply voltage when carrying out maintenance or repair activities on the system Install the unit in a dry well ventilated room with an ambient temperature between 5 and 40 degrees Celsius The electric power supply must be connected through an earth leakage switch of 30 mA separately installed for the swimming pool system Pre fuse max 16 A Additionally an operation switch in the power supply is recommended Comply with the regulations in all cases See the connection diagram for the connection of all components devices to the terminal strip Remark Do NOT forget to set the motor safety The heating output 220 240 V AC max 2 0 A is connected to the HEATER terminals Use an auxiliary relay for more switching power The solar output 220 240 V AC max 2 0 A is connected to the SOLAR terminals Use an extra auxiliary relay for more switching power Usually a motor valve is connected to the solar output Remark The motor valve is given the command to let the filtered water flow through the solar collector s or not Alternatively a 3 way motor valve 24 V AC can be applied This motor valve is connect
18. rature Filter control Heating Solar Backwash System Mode 4 ok Figure 4 Selection menu With the arrow keys you can select the function that you want to change Select the function concerned by pressing the OK key Filter control In this menu you can change the filter running times and the motor safety setting For example you Can set switch time 1 to 9 12 hours and switch time 2 to 14 18 hours as follows A total of 9 switch times can be programmed of which 1 8 are regular switch times Switch time 9 is for the winter position if the winter position has been enabled Only the set time of this switch time will be used then e g 15 minutes daily NOTE The pre programmed times for switching a filter on and off must always be on the same day Therefore it is NOT possible to start e g on Tuesday at 16 00 hours and to stop at 02 00 hours Then program start Tuesday at 16 00 hours and stop at 23 59 hours and on Wednesday start at 00 01 hours and stop at 02 00 hours So when switching overnight always split into two parts This also applies to the ALL position the option for applying the same switch time every day AS Control manual version 09 2012 Page 4 Overload protect Switch time 9 Switch time 8 Switch time 7 Switch time 6 Switch time 5 Switch time 4 Switch time 3