Home

product manual

image

Contents

1. boats Avoid locating near engine exhaust gases in the accommodation space Avoid running the engine when moored alongside objects such as a wharf a wall or another boat Avoid running your engine when docked in a crowded marina as vehicle and exhaust fumes can damage the alarm sensor For further information visit www boatsafetyscheme com 10 6 Using Your Alarm non digital version 7CO Recognising Alarm Signals and Warnings Feature What this means Required Action Green LED flashes every 30 seconds Normal operation None The alarm chirps every 60 seconds and the red Low batteries Replace batteries as soon LED flashes as possible Alarm chirps twice every 30 seconds and the End of life of the alarm Replace the alarm red LED flashes twice Alarm chirps every 30 seconds and red LED Replace the alarm flashes every 30 seconds Red LED on and constant tone Malfunction Replace the alarm Loud continuous alarm with the red LED Dangerous levels of CO Follow emergency proce have been detected dures see Page16 11 6 Using Your Alarm non digital version 7CO Testing Test your alarm each week by pressing the test button The alarm will beep once followed by 4 loud pulses then a brief pause and then 4 more pulses ending with a single beep While in full alarm the red LED will flash for 10 seconds This confirms that the alarm is powered up and working Re setting the Alarm If the alarm sounds the test rese
2. than 3 minutes CO Advice and Information The table below shows the effects of different levels of CO poisoning on the body Parts per Million PPM Effects on Adults 100 Slight headache nausea fatigue flu like symptoms 200 Dizziness and headache within 2 3 hours 400 Nausea frontal headache drowsiness confusion and rapid heart rate Risk to life after over 3 hours of exposure 800 Severe headaches convulsions vital organ failures Death possible within 2 3 hours 2 Important Safety Information If you recognise any of the above symptoms consult your Doctor immediately Young children elderly and pets are more susceptible to the dangers of CO Your Kidde alarm is designed to detect CO gas It is not designed to detect smoke fire or other gas such natural gas This product is intended for use in ordinary family homes It is not designed to meas ure compliance with occupational safety and the HSE Individuals with certain specific medical conditions may need an alarm that operates below 30ppm If this applies consult your Doctor IMPORTANT Ensure that all family members are familiar with the symptoms of CO poisoning and how your alarm works 3 Switching on Your CO Alarm NOTE Your CO alarm must be installed by a competent person using the guidance that follows 1 Remove the batteries from the pack and insert them into the battery compartment Make sure that you fit the batter
3. S Kidde Kidde Battery Carbon Monoxide Alarms 7CO Kidde Carbon Monoxide Alarm Contents Au PWN P What is Carbon Monoxide CO Important Safety Information Switching on Your CO Alarm Installation Instructions Recommended Locations Installation Instructions Mounting your alarm Using your CO Alarm Warning Signals Testing Re setting LCD read outs model 7DCO only Peak Level Display model 7DCO only Replacement Batteries End of Life What To Do If Your Alarm Sounds Maintenance of your Alarm Troubleshooting Product Specifications Warnings and Important Notices Warranty Information Environmental Protection Product Features and Specifications Test Reset Green Button Power LED Red Alarm LED Green Test Reset Power LED Button Carbon Monoxide Model 70 Alarm Model 7CO Carbon Monoxide Alarm Red gt Alarm LED Peak Level Model 7DCO Peak Level Button Model 7DCO Digital Display 1 What is Carbon Monoxide Carbon monoxide CO is a highly poisonous gas with no taste colour or smell Potential Sources of CO This CO alarm is not a substitute for the correct maintenance of your Wood burning stoves appliances Gas boilers and fires Gas Hobs Carbon monoxide can be produced from poorly burning appliances Oil and coal burning appliances or from blocked flue
4. T THE MANUFACTURER OR SUPPLIER AND DO NOT CONTINUE USING THE ALARM 20 13 Warranty TEN YEAR LIMITED WARRANTY WARRANTY COVERAGE THE MANUFACTURER WARRANTS TO THE ORIGINAL CONSUMER PURCHASER THAT THIS PRODUCT WILL BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF TEN 10 YEARS FROM DATE OF PURCHASE THE MANUFACTURER S LIA BILITY HEREUNDER IS LIMITED TO REPLACEMENT OF THE PRODUCT REPAIR OF THE PRODUCT OR REPLACEMENT OF THE PRODUCT WITH REPAIRED PRODUCT AT THE DISCRETION OF THE MANUFACTURER THIS WARRANTY IS VOID IF THE PRODUCT HAS BEEN DAMAGED BY ACCIDENT UNREASONABLE USE NEGLECT TAMPERING OR OTHER CAUSES NOT ARISING FROM DEFECTS IN MATERIAL OR WORKMANSHIP THIS WARRANTY EXTENDS TO THE ORIGINAL CONSUMER PURCHASER OF THE PRODUCT ONLY Warranty Disclaimers Any implied warranties arising out of this sale including but not limited to the implied warranties of description merchantability and fitness for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in tort or otherwise The Manufacturer shall have no liability for any personal injury property damage or any special incidental contingent or consequential damage of
5. ane Iso propanol Ethylene Benzene Toluene Ethyl acetate Hydrogen Sulphide Hydrogen Sulphur Dioxide alcohol based products paints thinners solvents adhesives hair sprays aftershaves or perfumes and some cleaning agents 17 10 Troubleshooting Symptom LCD Screen Display model 7DCO UK only Problem Action Required Single chirp every 60 Low batteries Change the batteries seconds plus flashing 11 red LED L Single chirp every 30 Replace alarm seconds plus flashing Alarm fault contact Kidde if still in red LED crr warranty Red LED on and con Replace alarm stant tone Alarm malfunction contact Kidde if still in warranty Two chirps plus red LED flashes twice r End of Life of the alarm Replace the alarm cru 18 11 Product Specifications Power 3 x AA batteries as supplied Sensor Electrochemical CO Sensor Accuracy Depending on the ambient condition temperature humidity and the condition of the sensor the alarm readings may vary The digital readings tolerances are Ambient 27 C 12 C 80 F 10 F atmospheric pressure 10 40 3 relative humidity Temperature Range Operating range 0 C to 40 C Humidity up to 90 relative humidity RH Alarm Sound At Least 85dB A at 1 metre 3 4 0 5 KHz pulsing alarm Size and weight Weight 160g D
6. any kind resulting from gas leakage fire or explosion This warranty does not affect your statutory rights Warranty Performance During the above warranty period your product will be replaced with a comparable product if the defective product is returned postage prepaid to KIDDE Safety Europe Ltd Mathisen Way Colnbrook Slough SL3 OHB Telephone 01753 685148 together with proof of purchase date Please include a note describing the problem when you return the unit The replacement product will be in warranty for the remainder of the original warranty period or for six months whichever is longer Other than the cost of postage no charge will be made for replacement of the defective product Important Do not open unit Opening unit will void warranty Your Carbon Monoxide Alarm is not a substitute for property disability life or other insurance of any kind Appropriate insurance coverage is your responsibility Consult your insurance agent Kidde makes no warranty express or implied written or oral including that of merchantability or fitness for any particular purpose with respect of the batteries For Warranty Service In many cases the quickest way to exchange your CO alarm is to return it to the original place of purchase If you have questions call the KIDDE customer service department on 01753 685148 21 14 Environmental Protection Waste electrical products should not be disposed of with household waste Please recycle where fac
7. ies correctly to the polarity markings or shown within the battery compartment If correctly installed the alarm will give a short beep To test the alarm press the test button The alarm will beep once followed by 4 loud pulses then a brief pause and then 4 more pulses ending with a single beep If you have a digital read out alarm model 7DCO the LCD screen will show and then 888 before settling at 0 Check that the green LED flashes at 30 second intervals to show that the alarm has power This is easiest to see in a dark area or with lights switched off 4 Installation Instructions Recommended Locations Recommended Locations Not Recommended Place the alarm at least 2 metres from fuel burning appliances and not more than 4 metres away Do not place closer than 2 metres from fuel burning appliances Away from draughts such as doors and windows Do not wall mount close to obstructions e g behind curtains shelving or furniture Within hearing distance of bedrooms If heating appliance is in the bedroom place the alarm at sleeping height Do not fit in dusty dirty or greasy areas e g garages or workshops If wall mounting install at eye level approx 1 5m and at least 30cm from adjoining walls or ceiling Do not wall mount within 30cm of the ceiling as this is a dead air space If free standing the unit should be placed no more than 1 metre from the g
8. ilities exist Check with Local Authority or retailer for recycling advice 22 Useful Contact Information Kidde Helpline Emergency No s CoGDEM CO Advice Line Kidde Website Manufacturer Address UK 0800 917 0722 Ireland 1800 318 601 Gas Emergency Services 0800 111 999 HETAS Solid Fuel Emergency 0845 634 5626 Oftec oil 0845 658 5080 0800 1694 457 www kiddesafetyeurope co uk Kidde Safety Europe Limited Mathisen Way Colnbrook Berkshire SL3 OHB P N 2530 7202 02 23
9. imensions 118mm x 70mm x 40mm 19 12 Warnings and Important Notices A WARNING THIS CARBON MONOXIDE ALARM IS NOT A SUBSTITUTE FOR INSTALLING AND MAINTAINING AN APPROPRIATE NUMBER OF SMOKE ALARMS IN YOUR HOME THIS ALARM WILL NOT SENSE SMOKE FIRE OR ANY POISONOUS GAS OTHER THAN CARBON MONOXIDE FOR THIS REASON YOU MUST INSTALL SMOKE ALARMS TO PROVIDE EARLY WARNING OF FIRE AND TO PROTECT YOU AND YOUR FAMILY FROM FIRE AND ITS RELATED HAZARDS WARNING THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR RESIDENTIAL AREAS IT IS NOT DESIGNED TO MEASURE COMPLIANCE WITH COMMERCIAL AND INDUSTRIAL STANDARDS THIS ALARM IS NOT SUITABLE FOR INSTALLATION IN HAZARDOUS LOCATIONS INDIVIDUALS WITH MEDICAL PROBLEMS MAY CONSIDER USING WARNING DEVICES WHICH PROVIDE AUDIBLE AND VISUAL SIGNALS FOR CARBON MONOXIDE CONCENTRATIONS UNDER 30 PPM IMPORTANT THIS CARBON MONOXIDE ALARM IS DESIGNED TO DETECT CARBON MONOXIDE FROM ANY SOURCE OF COMBUSTION INCLUDING IMPROPER OR MALFUNCTIONING APPLIANCES THE INSTALLATION OF THIS DEVICE SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS A WARNING THIS ALARM WILL NOT WORK WITHOUT POWER THIS ALARM REQUIRES A CONTINUOUS SUPPLY OF POWER A WARNING THIS UNIT IS NOT A SMOKE ALARM IT WILL NOT SENSE SMOKE FOR EARLY WARNING OF FIRE YOU MUST INSTALL SMOKE ALARMS IMPORTANT IF ANY FAULT SIGNALS OCCUR CONTAC
10. n of the alarm indicates the presence of Carbon Monoxide CO which can kill you If alarm sounds 4 loud audible pulses followed by a pause for 5 seconds 1 Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not re enter the premises nor move away from the open door window until the emergency services responders have arrived the premises have been aired out and your alarm remains in its normal condition 2 Call Gas Emergency Services 0800 111 999 or your local Gas Safe Registered Engineer PHONE NUMBER Never restart the source of the CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the test reset button will terminate the alarm If the CO condition that caused the alert in the first place continues the alarm will reactivate If the unit alarms again within six minutes it is sensing high levels of CO which can quickly become a dangerous situation 16 9 Maintenance of Your Alarm To keep your alarm in good working order Test every week Vacuum regularly to remove dust Keep away from solvents or detergents Avoid spraying air freshener hair spray near the alarm Do not paint the alarm If decorating or using adhesives close to the alarm remove it temporarily The following substances can affect the sensor and cause false alarms Methane Propane Iso but
11. round to avoid permanent damage in case acci dently knocked Avoid humid bathrooms cold lt 4 C or hot gt 40 C areas and away from sinks It is recommended that at least one Kidde carbon monoxide alarm is installed on each level of the home 8 5 Installation Instructions Mounting THIS ALARM MUST BE INSTALLED BY A COMPETENT PERSON AND IS TO BE INSTALLED AC CORDING TO THESE INSTRUCTIONS Wall mounting 1 Drill two holes in a wall 7cm 2 3 8 apart you may wish to use the back plate for guidance 2 Insert the two rawl plugs that are supplied into the holes 3 Insert the two screws as supplied into the holes ensuring enough of the screw sticks out of the wall approx 3mm 4 Hook the alarm over the screws Free standing 1 No more than 1 metre from the floor to minimise this risk of the alarm being permanently damaged should it be knocked to the floor from a greater height 2 Make sure the alarm is in the upright position and not lying flat on the surface 9 5 Installation Instructions for Caravans and Boats As well as being recommended for use in homes this alarm is approved for use in caravans motor homes and boats Alejo In addition to following COGDEM www cogdem org uk and NCC guidelines e Do not install directly above a source of heat or steam Avoid locating close to vehicle and exhaust fumes as these can damage the alarm sensor In addition to the instructions for
12. s and chimneys Portable gas heaters Blocked flues and chimneys If your alarm has sounded and you have ventilated the room the CO Fumes from integral garages may have dispersed before help arrives It is crucial that the source Barbecues of CO is determined and appropriate maintenance carried out Carbon monoxide is a cumulative poison Longterm exposure to low levels may cause symptoms This Kidde alarm is time weighted the higher the level of CO the sooner it will alarm 3 2 Further information for Caravan and Boat Owners The following can lead to carbon monoxide being produced Using LPG cooking appliances for space heating Leaving LPG appliances on overnight Barbecues within the boat cabin or near a caravan door e g under an awning To be safe know the possible sources of CO in your home Keep fuel burning appliances chimneys and vents in good working condition Learn the early symptoms of exposure and if you suspect CO poisoning move outside into fresh air and get emergency help Your first line of defence is an annual inspection and regular maintenance of your appliances Contact a licensed contractor or call your local utility company for assistance 2 Alarm levels as defined by EN50291 2010 The table below shows the response times at which your CO alarm will sound Parts per Million PPM of CO Time until Alarm 50 60 90 minutes 100 10 40 minutes 300 Must alarm in less
13. t button will silence the alarm unless it is still detecting dan gerous levels of CO The green light will then flash every 30 seconds to indicate that the alarm has power 12 6 Using Your Alarm for Digital unit only 7DCO Additional features for the CO alarm with the digital display screen model 5DCO Digital Screen LED Sound emitted What this means Required action Green flash every None Normal operation None 1 30 seconds LCD will not show levels lt a 30ppm Red LED flashes Full alarm Dangerous levels of CO has been Follow emergency procedures see a detected Page 16 Red LED flashes 1 beep then 2 Successful test or reset sequence None this is part of the standard test sets of 4 beeps in operation or reset procedure LULL followed by 1 beep Red LED flashes Chirp every 60 Low batteries Lb Change batteries h every 60 seconds seconds Red LED flashes Chirp every 30 Fault Replace the alarm Le seconds err Red LED on Constant tone Malfunction Replace the alarm Red LED flashes Chirps twice End of Life Replace the alarm roo twice every 30 vt seconds 6 Using Your Alarm for Digital unit only Cont d Peak Level Display Press peak level button to display the most recent CO reading between 11 999 This feature is useful to help you to know what levels of CO may have been detec
14. ted in your absence so corrective action can be taken such as servicing your boiler NOTE The peak level memory is cleared to zero if the test and peak level buttons are pressed at the same time or by removal of the batteries CO levels up to 30ppm can occur under normal non dangerous conditions Such conditions could include nearby heavy traffic starting a vehicle in an attached garage starting a fire nearby charcoal barbecue 14 7 Replacement of Batteries End of life Low Batteries Type of Alarm LCD LCD Sound Emitted Non Digital N A Green Red flashes every 30 Chirp every 30 seconds seconds Digital LCD Screen Lb Green Red flashes every 30 Chirp every 30 seconds seconds Slide alarm from back plate Recommended Batteries Duracell MN1500 MX1500 Gold Peak 15A noting polarity see sketch Golden Power GLR6A Energizer E91 Insert 3 x replacement AA batteries if PAA Battery I Replace back plate and test the alarm Under normal operating conditions the batteries will last a minimum of one year These batteries can be purchased from your local retailer End of life This alarm will chirp every 30 seconds with a red LED flash after at least 10 years operation to let you know it has reached its end of life A replacement needs to be purchased 15 8 What to do if Your Alarm Sounds Carbon Monoxide Alarm Procedure Z WARNING Activatio

Download Pdf Manuals