1. Cable Details RS232 Side of SC10 EJ to any other Serial Port RX TX RTS TS GND SC10 EJ Side PC COM Port Figure 6 Cable Details RS485 4 Wire Signal Will Connect To TX Output of SCIO EJ RX of your Device TX Output of SCIO EJ RX of your Device RX Input to SC10 EJ TX of your Device Input to SC10 EJ TX of your Device 5 Table Cable Details RS485 2 Wire Will Connect To Bi Directional Signal TX of your Device Bi Directional Signal TX of your Device Table 6 8 Back to Back 1 1 scheme For back to back communication between two SCIOEJ make the Connection as follow Serial Master Serial to Ethernet SC10EJ 2 Salve Serial Slave device Serial to Ethernet SC10EJ 1 Master Serial link Procedure 1 Configure Ethernet Converter as a Master amp the other Ethernet Converter as Slave 2 Connect the Master converter to the Serial Master device A device which is requesting for data from slave device If application software is your Master device then the Ethernet Master converter will connect to that PC s com port 3 Connect the Slave converter to your serial device which is responding to requests from the Master Serial Device For Configuration of Master and Slave in SCIOEJ follow step as below Set one SC10 EJ as a Master mode and another SC1OEJ as a Slave mode through option available with config utility i e Operation Mode Configure t
2. Default None Stop Bits Select Stop bits from 1 bit 2 bits Default 1 bit Data Bits Select Bits per byte from 7 bits byte 8 bits byte Default 8 bits byte Flow Control Select Flow control as None RTS CTS Default None Maximum Intercharacter Delay SC10 EJ packets the Serial data amp sends it to Ethernet If the characters in the packet are less than 255 bytes the above parameter will come into play After last character has been received from serial side the converter waits for this time before sending the packet Value of 0 disables this function Actual delay is calculated as Maximum Intercharacter Delay X 10ms i e it can be in the 10 2550ms range Default 10 i e 10 msec Connection Timeout Specifies timeout in minutes for the TCP IP connections in case there is no transaction of data in any direction Timeout should be in the range 0 to 255 Value of O disables this function connection never times out Default 5 5 minutes Destination IP Defines the Destination IP Address It should be in dot decimal format 1 e 198 168 106 14 Default 0 0 0 0 Destination Port Number Defines the destination data port number Between 0 to 65535 range Except Port number 65535 Default 1001 Gateway IP address Defines the IP address of the Network s Gateway to which the SC10 EJ is connected It should be in dot decimal format i e 128 0 0 1 Default 0 0 0 0 SubNet Mask Addres
3. Enter Select IPAddress 192 168 106 23 N ee of SC10 pa 3 Search for the SC10 EJ Converter by pressing Search Button a hn on the utility SC10 Settings 4 Ifonly one SC10 EJ converter is present on the network then TRER an IP address setting dialog box will appear in this box Set the preen a IP address as pre your network configuration Mose 5 If more than one SC1O EJ converter are attached to the as network then a list box containing MAC address of the Curent 192 168 106 23 converters will appear From this list select any MAC address New Write and set the IP address for the corresponding converter 6 After IP address has been set select Ethernet under ee Programming SC10 through Option Enter the Set IP Version lt 4 00 S 4N Device 4209 Save and Exit Sa Figure 3 Address in Drop Down list given in front of Enter Select IP Address of SC10 Now press Login again Page 3 of 10 San Telequip P Ltd 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 Phone 020 24320023 65001587 email info santelequip com ag SAN TELEQUIP Connecting Converting Leading Note a Make sure that the IP of the converter and PC are within the same range I e if the IP address of the converter is 192 168 106 xxx then the IP address of the PC must be 192 168 106 yyy b To make sure the converter is reachable you can Ping the converter c The IP
4. The utility will fetch the current value from the converter and display on screen The new value then can be entered and sent to converter by pressing Write Button Figure 4 All the network settings can be done exactly as per already specified configuration steps for a Configuration through Serial and b configuration through Telnet C 10 Config2 3 Communication About Auto Detect Set IP Address Of SC10 Compatible to Local Network Search Set New IP Programming SC10 Through Ethemet Enter Select IPAddress 192168 106 23 of SC10 Login C COM SC10 Settings Baud Rate v Serial Settings Value Current Result SO Version lt V4 00 S 4N Device 4209 Save and Exit Debug Figure 5 San Telequip P Ltd NO 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com CONFIGURATION THROUGH HTTP IE Open Internet Browser using the IP of the device Proceed as per the screens below gt C10 Setup Windows Internet Explorer AJ C10 Setup Windows Internet Explorer M http 192 168 106 111 update htm v Bex 00g B O http 41192 168 106 111 p v KIX coge Ha R o
5. address of the PC can be configured from Control Panel gt Network gt Protocol gt TCP IP Properties d If the connection is established the appropriate version and a message will be displayed at the bottom of the window When the desired settings are done converter should be returned to Normal Mode by pressing Save amp Exit button on the utility Network Settings C 10 Config 3 Communication About Auto Detect Set IF Address OF SC10 Compatible to Local Network Search Set New IF Programming SCO Through Etheret EnterSelect IPAddress 192 168 106 23 of SC1O Login f COM SC10 Settings IP Address kai Network Network Settings Value Current Transport Protocol Operation Mode 3 Connection Timeout Gateway P Address Result eenn Version lt V400 5 N Device 4209 Save and Exit Debug Figure 4 Serial Settings To set any parameter of serial settings select the parameter from the Drop Down List The utility will fetch the current value from the converter and display on screen The new value then can be entered and send to the converter by pressing Write Button Figure 5 All the serial settings can be done exactly as per already specified configuration steps for a Configuration through Serial and b configuration through Telnet Page 4 of 10 To set any parameter of network settings select the parameter from the drop down list
6. used apart from Tx Rx and GND 5 COMMUNICATION PORTS DETAILS Serial Port Details Port Pin Pin RS 232 RS485 2 4 Wire options are available as default for Serial Communication through a 9 Pin Howder connector Pin Details of Serial Port is as alongside Table 2 Ethernet Port The SC10 EJ Converter has a RJ 45 Ethernet port The SC10 EJ is connected using the Straight Ethernet Cable when connected via a Hub Switch or a Cross Ethernet Cable when connected directly to the PC 6 DIP amp LED s Status Indications DIP Details Set DIP Switches as given below depending upon the communication standard required by you DIP 1 DIP2 DIP3 DIP4 Config Mode RS485 2 Wire RS232 RS485 4 Wire Normal Mode Table 3 CIPS DIP NOTE DIP1 is to be turned ON only if the configuration is being done through RS232 port NOTE Turn DIP 1 OFF after configuration through Serial Port amp Reset the Converter LED Indicators Operation LED No LED 2A Active when Link is established LED 2B Active when collisions occur LED 4A Reception on Serial side Active when Data received LED 4B Transmission on Serial side Active when Data is transmitted Table 4 Page 6 of 10 San Telequip P Ltd NO 4 Crystal House 235 Navi Peth om zm ge Off LBS Road Pune 411 030 O SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com 7 Cable Details
7. C Side Utility Through Telnet This mode is used to configure the SC10 EJ s functional parameters settings via the Serial port If at Power On DIP 1 amp 3 are ON you can enter the Configuration mode NOTE DIP1 is to be turned ON only if the configuration is being done through RS232 port Turn DIP 1 OFF after configuration through Serial Port amp Reset the Converter Normal Mode If at Power ON DIP 1 is OFF then SC10 EJ will go in Normal operating mode In TCP Slave mode it will directly go in Disconnect State waiting for connection while in case of TCP Master Mode it will try to establish connection with remote device In the Normal mode SC10 EJ performs the data conversion from Ethernet to Serial and vice a versa Page 1 of 10 San Telequip P Ltd NO 4 Crystal House 235 Navi Peth T TE Off LBS Road Pune 411 030 O SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com 3 Configuration Procedure Through Serial Port Configuration Procedure Through Serial Port 1 Make DIP 1 amp 3 ON 2 Connect Tx Rx and Gnd of SC10 EJ to the COM Port of the PC as per fig 5 3 Start HyperTerminal on PC 4 Select the same COM Port of the PC to which SC10 EJ is connected 5 Setup Hyper Terminal with following settings a Baud Rate 9600 bps b DataBits 8 c Parity None d Stop bits A e Flow Control None Power On SCIO EJ A Configuration Men
8. Delay MiliSeconds 10 Connection Timeout Minutes 5 Destination IP address 192 168 106 82 Destination Port 1001 Gateway IP address 192 hee lioe 50 Subnet mask 255 255 255 L0 Operation Mode Slave Protocol v UPDATE Done P Internet 100 7 Network Parameter Setting Page 5 of 10 San Telequip P Ltd NO 4 Crystal House 235 Navi Peth om zm ge Off LBS Road Pune 411 030 O SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com 4 OPERATION INNORMAL MODE Ensure that you have configured the SC10 EJ before entering this mode If at Power On DIP 1 is OFF then SC10 EJ will go in Normal operating mode In the Normal Mode there are two sub modes of operation TCP Slave Mode In Slave Routing Mode SC10 EJ is always in Listen State Waiting for a connection The connection command must be from peer side In the Slave Mode SC10 EJ will work with any station on the network that contacts it irrespective of settings of Destination IP and Destination Port number in SC10 EJ s Configuration parameters TCP Master Mode In the Master Routing Mode SC10 EJ always initiates a connection with remote device whose IP Address amp Port no s is set as destination IP amp port no s for SC10 EJ Serial to Ethernet Data transfer using RTS CTS If Flow control is enabled additionally RTS and CTS lines are
9. P scio setup A v I me Page v G Tools R gh SCIO Setup la A D im v T page 3 Took Configuration Menu SC10 Configuration Menu C10 MAC address i le ip lh e e MAC address i lb l Ib lhs Source IP address 192 liee ho Lim Source IP address 192 Lhee Lho Lin Source Port Number 502 Source Port Number 502 Baud rate Parity Data and Stop bits 9600 v None v 8 v1 v Baud rate Parity Data and Stop bits 9600 v None v 8 v1 v Flow Control Flow Conti o Max Interchar Delay MiliSeconds 10 Max Interchar Delay Milliseconds ba Connection Timeout Minutes Connection Timeout Minutes 19200 Destination IP address 192 68 106 82 Destination IP address Fem e Lo 2 ae hectinat 115200 Destination Port Destination Port 23040 Gateway IP address 192 468 106 50 Gateway IP address 768008 Lio 50 Subnet mask s Les Loss Lo Subnet mask ss oss Ls o Operation Mode Slave v Operation Mode Slave i Protocol TCP w Protocol TCP v we TTT Ta 4 p Done P Internet 100 Dos P Internet 100 a Default Page Serial Parameter Setting C10 Setup Windows Internet Explorer GD Et f192 168 106 111 l a og Ba OT Escos A Al me Eler Go Configuration Menu C10 MAC address n le Ib e Ii Source IP address UI Source Port Number 502 Baud rate Parity Data and Stop bits 9600 y None v8 v 1 v Flow Control None w Max Interchar
10. San Telequip P Ltd NO 4 Crystal House 235 Navi Peth om zm ge Off LBS Road Pune 411 030 O SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com Document Name User Manual for SC10EJ Serial to Ethernet Converter INDEX Technical Specifications Modes of Operation 3 Configuring the SC10 EJ Through Serial Port a Configuring the SC10 EJ Through Telnet b Configuring the SC10 EJ Through Ethernet side Utility c Configuring the SC10 EJ Through HTTP Ne OY INDDANWWNR 4 Operation in Normal Mode 5 Communication Ports Details of SC10 EJ 6 DIP Settings amp LED Status Indicators 7 Cable Details 8 Back to Back Scheme 9 Configuration for Virtual Com Port SC10 EJ is Serial to Ethernet PCB Module It is an Interface Converter between Ethernet and RS232 RS485 2 4 Wire devices The Serial amp Ethernet Ports along with the LED indications are on the front facia the Power Supply jack is on the Right Back side amp the DIP switches on the Right Front side 1 TECHNICAL SPECIFICATIONS Communication Interfaces S o Ethernet Interface 10 100 Base Mbps D Mechanical Connectors Power Supply S O Environmental Table 1 2 MODES OF OPERATION The SC10 EJ Converter operates in the following modes Configuration Mode Through Serial Mode By any Terminal Software or our PC Side Utility Through Ethernet Mode Our P
11. he destination IP of the Master Converter as same as the source IP address of the Slave converter Configure the destination Port number of the Master Converter as same as the source Port number of the Slave converter Ensure Serial parameters of Master and Slave are identical Before going for required application setup check basic communication test by telnet and HyperTerminal E Ll 2L Page 7 of 10 San Telequip P Ltd 4 Crystal House 235 Navi Peth OQ TE LE Off LBS Road Pune 411 030 So SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com CONFIGURATION FOR VIRTUAL SERIAL PORT CONSOLE VER 2 7 0 gt Unzip from SC10EJConfig Virtual Com Vserport zip in the enclosed CD gt Double click on required exe File F VirtualSerialPort Console 2 7 0 VirtualSerialPort Console Console Options Auto run when login Minimize when run gt Follow the below screens to install the Virtual Com Port gt Right Click inside the above screen to get Add the Port Option VirtualSerialPort Console 2 7 0 Setting COM Fort OMe Cancel oa Add Port Remove Port m m TCF Client Remote Address Remote Port TCP Server Listen Fort UDP Local Port Console Options Port Options Auto run when login Send tonet delay time ms g Set Minimize when run Receive from net delay time ms 0 Set PY Case Remo
12. s It defines whether the Destination IP address is considered to be on the local network segment or foreign network segment It should be in dot decimal format i e 255 255 255 0 Default 0 0 0 0 Page 2 of 10 San Telequip P Ltd 4 Crystal House 235 Navi Peth ag rch Off LBS Road Pune 411 030 SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com Operation Mode Selects Slave or Master Routing Mode Default Slave Configuration Procedure Through Telnet Tel 91 20 24334423 24339634 35 Fax Extn 40 1 Go to Start gt Run Configuration Utility For SC10L Uer SC10L Uer 1 12 00 2 Type Command C ant Settings a 3 MSDOS Command Prompt will be ajEthernet MAC ADDRESS 880 808 2260 6000 600 116 b Source IP Address 192 168 106 011 displayed c Source Port Number 1001 Baud Rate 9600 4 Type C telnet 192 168 106 11 Type jParity NONE e F Stop Bits i previously set Source IP address for E Control Ai present configuration and press Enter ijMax Interchar Delay 081 5 j Connection Timeout oe Configuration menu will be displayed as k jDest IP Address 192 168 012 LjDest Port Number 61601 shown in the scresnshot below mjGateway IP Address 128 6806 e017 i njSubnet Mask Address 255 255 pap diagram o Operation Mode SLAVE pyExit After the Configuration menu is displayed configuration should be done in
13. snap shots are below gt Inthe next screen you are required to insert Network details VirtualSerialPort Console 2 7 0 VirtualSerialPort Console COM Unconnectsd Femmend Ds 3 Console Options Auto run when login Minimize wher run Page 9 of 10 Add Por Remove Port Add Net Fort Options Send to net delay time ms Loopback mode _ Receive from net delay time ms b ase Detect timeout Add Net Settin COM Port com In Use f TCP Client TCP Server E UDP TCP Chien Remote Address f 92 168 106 23 TCF Serve Remote Fort 504 Listen Pork Uo Local Pork Remote Address 127 0 0 1 Remote Port 31000 Receive from net delay time ms jo Set _logfie Ast _ Set I Loopback mode JV Detect timeout P saj x Cancel San Telequip P Ltd NO 4 Crystal House 235 Navi Peth DRE FARE Off LBS Road Pune 411 030 SAN TELEQUIP Phone 020 24320023 65001587 Connecting Converting Leading email info santelequip com Following screens are the confirmation of the IP selected amp communication established palsies ioixi VirtualSerialPort Console VirtualSerialPort Console mee CONS Connecting Command Port 192 168 106 24 65531 o Connected TCP Client 192 166 106 24 100 EEL CONS Unconnected Command Port Unconnected TCP Client 192 166 106 24 100 Port Options Send to net delay
14. te Address 27001 Remote Port Loopback made _ Detect timeout Add Port gt The following screens below will appear gt Select Continue Anyway gt Selected COM Port will be Added Port no s 8 in the picture is only for reference Page 8 of 10 San Telequip P Ltd 4 Crystal House 235 Navi Peth Off LBS Road Pune 411 030 Phone 020 24320023 65001587 email info santelequip com ag SAN TELEQUIP Connecting Converting Leading F YirtualSerialPort Console 2 6 1 Console Options JV Auto run wher Hardware Installation A The software you are installing for this hardware Virtual Serial Port has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Minimize when run Continue Anyway STOP Installation 215 x F irtualSerialPort Console 2 6 1 VirtualSerialPort Console Unconnected Command Port M Console Option m Port Option J Auto run when login Send to net delay time ms JV Minimize when run gt Right Click on the added COM port amp choose Add Net option The
15. the same way as is done for Serial Port configuration through Hyper Terminal Enter Selection a o TO CHANGE THE PARAHETERS ENTER THE VALID PASSWORD Following features are provided while using Telnet menu Figure 2 1 If communication is established and data transfer is in progress and Telnet menu is invoked then the user will be asked to enter valid PASSWORD Once user enters valid password Data transfer will stop and Configuration menu will be displayed Default password is net and is case sensitive 2 If Telnet menu is invoked and valid Password is not entered for one minute then connection to host ID Le Device is lost 3 If valid password is entered and menu is displayed but afterwards no action is performed to change any of the parameters then connection to device is lost 4 After changing the parameters when we press p or P to end the configuration Configuration Procedure through Ethernet Mode PC side utility provided H SC 10 Config2 3 When configuring the SC10 EJ through PC side utility use the Communication About following Steps Auto Detect l 1 Start SC10 EJ Config utility Through shortcut on desktop or Set IP Address Of SC10 Compatible to Local Network Search Set New IP through Start gt Programs gt SC10Config gt SC10Config 2 Go to step 3 if IP address of SC10 EJ converter is not according Programming C10 Through 2 to the required local network settings fe Ethemet
16. time ms fo Set Receive from net delay time ms jo Set ogie FASC _Set I Loopback mode JV Detect timeout Console Options Console Options Port Option JV Auto run when login IV Auto run when login Send to net delay time ms fo Set IV Minimize when run Receive from net delay time ms jo Set Log File ASC Set I Loopback mode JV Detect timeout IV Minimize when run Congratulations The Virtual Com Port is installed Page 10 of 10
17. u with all the default parameters will be displayed as shown below nal 1 x Fle Edt View Cal Transfer Hep fuser wishes to change any of the default parameters simply type corresponding letter viz b or B for setting IP Address etc then list of current Configuration Utility For scion set value and options available for that particular Yen a Selon TP Tialli parameter will be displayed Enter the option Current Settings Ethernet MAC ADDRESS 000 008 220 000 000 079 required and upon pressing Enter key same value Source IP Address 192 168 106 011 x 3 t E 01001 will be again displayed in configuration menu as 1 default parameter Flow Control Max Interchar Delay 005 Connection Timeout 0 01 Various Configuration setting options available in Dest IP Address 192 168 106 014 Dest Port Number a EE SC10 EJ are Gateway IP Address Subnet Mask Address 255 255 255 000 an bP FQ Mo TOV RBrRAWU Operation Mode SLAVE nae IP Address Enter Selection a o a on It should be in Dot Decimal format i e 192 168 106 111 Default 127 0 0 1 Connected 0 00 16 Auto detect 96008 N 1 SCROLL caPS NUM Capture Print echo Figure 1 Port Number It must be in 0 to 65534 range Except Port number 65535 Default 1001 Baud Rate Select from 1200 2400 4800 9600 19200 38400 and 57600bps Default 9600bps Parity Select Parity from None Even Odd
Download Pdf Manuals
Related Search
Related Contents
Version 4.0 MANUAL Philips Go Gear Universal AV Docking Kit PAC009 Remington D5210 Lifetime Outdoor Storage 60079 User's Manual Eco Style Metro Portable Winch Company 電子化ドキュメントの活用 Copyright © All rights reserved.
Failed to retrieve file