1. JY997D12601G 4 MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEC F JAPANESE ENGLISH FX 232AWC H USER S MANUAL Manual Number JY997D12601 Revision G Date April 2015 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Effective April 2015 Specifications are subject to change without notice 2004 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories Z WARNING and A CAUTION Indicates that incorrect handling may cause hazardous Z WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous Z CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by A CAUTION may also cause sev
2. TRANSPORT AND STORAGE Z CAUTION Manual name Manual No Des PRECAUTIONS FX Series User s Explains N N network Parallel e The product is a precision instrument During transportation avoid any impacts JY997D16901 z rs f Manual Data _ MODEL CODE Link Computer Link Non Failure to do so may cause failures in the product Communication 09R715 Protocol communication by RS After transportation verify the operations of the product Edition and RS2 instructions FX2N 232IF How to obtain manuals For product manuals or documents consult with the Mitsubishi Electric dealer from who you purchased your product 1 Outline The FX 232AWC H is a RS 422 RS 232C converter to connect the FX series PLC with a personal computer 1 1 Incorporated Items Verify that the following product and items are included in the package Product FX 232AWC H type interface unit Included items User s Manual this manual 2 14 General Specifications The general specifications are equivalent to the PLC main unit For general specifications refer to the manual of the PLC main unit 2 2 Electrical Specifications 5V DC power is supplied from the internal power power supply of PLC Current consumption 120mA or less Level Conversion Bidirectional between RS 422 and RS 232C 115200 bits per second maximum Boudika The baud rate is different in connected equipment 3 System Configuration The system configuration according
3. ere injury It is important to follow all precautions for personal safety Associated Manuals 1 2 External Dimensions and Part Names Unit mm inches 25 0 99 mn RS 422 Connector D SUB 25Pin female 80 3 15 Hole of screw for the connector fixation M2 6 metric screw thread POWER Lamp Green RS 232C Connector D SUB 25Pin female MASS Weight 0 1kg 0 22Ibs 2 Specification INSTALLATION PRECAUTIONS Z CAUTION e Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur STARTUP AND MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric distributor e Since the FX 232AWC H case is made of resin do not drop it or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS Z CAUTION e Please contact a certified electronic waste disposal environmentally safe recycling and disposal of your device company for the
4. nicate Check if the correct cable is connected between the FX 232AWC H and the personal computer Confirm whether the selection of the communication setting and the connected model is correctly set referring to the manual of the software which is installed on the personal computer POWER Lamp is lit The DC5V power supply from PLC is not supplied Confirm the items below Ensure that the FX 232AWC H and the PLC are connected with the specified cable Confirm whether the power supply is supplied to the PLC POWER Lamp of PLC lights when the power supply is correctly supplied to the PLC Confirm whether the DC5V power supply capacity of PLC is sufficient The PLC supplies DC5V to the special function blocks The PLC will not operate when a configuration that exceeds the DC5V capacity is used It will also be impossible to communicate normally POWER Lamp is not lit Note Concerning the CE Marking The CE marking does not guarantee that an entire mechanical module produced in accordance with the contents of the notification comply with the following standards Compliance to EMC standards of the entire mechanical module should be checked by the user manufacturer Standards with which this product complies Type Programmable Controller Open Type Equipment Models Products manufactured from July 1st 2004 Electromagnetic Compatibility Standards EMC EN61000 6 4 2007 Electromagnetic compatibility Gene
5. ric standards Emission standard for Industrial environment EN61131 2 2007 Programmable controllers Equipment requirements and tests Remark Compliance with all relevant aspects of the standard Radiated Emissions and Mains Terminal Voltage Emissions Compliance with all relevant aspects of the standard Radiated electromagnetic field Fast transient burst Electrostatic discharge Damped oscillatory wave Conducted RF High energy surge and Power frequency magnetic field EN61000 6 2 2005 Electromagnetic compatibility Generic standards Immunity for industrial environments Compliance with all relevant aspects of the standard RF immunity Fast transients ESD Conducted Surges Power magnetic fields Voltage dips and Voltage interruptions Notes for compliance to the EMC regulation It is necessary to install the FX 232AWC H module in a shielded metal control panel For more details please contact the local Mitsubishi Electric sales site Attention e This product is designed for use in industrial applications Note e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a res
6. to the connected equipment can be found in the manual of the PLC main unit positioning unit programmable cam switch or peripheral equipment Additionally when using Non Protocol communication with the standard built in port of the FX3G Series PLC refer to the FX Series User s Manual Data Communication Edition A 4 Connecting Procedure The procedure for connecting to peripheral equipment is shown 1 Power off the PLC 2 Remove the connector cover of the FX 232AWC H 3 Connect the cables to the connectors of the FX 232AWC H For the selection of the cable refer to the manual of the connected equipment or peripheral equipment 4 Fix the connector of the FX 232AWC H and the connected cable with the fixing screws 5 Power ON the PLC 6 Power ON the Personal computer 7 Make sure the POWER Lamp of the FX 232AWC H is lit The POWER Lamp of the FX 232AWC H lights when the power supply is normally supplied by the PLC 8 When the FX 232AWC H is not in use reattach the connector cover to prevent dust from entering 5 Troubleshooting When it is not possible to communicate between the PLC The positioning units and the programmable cam switch are included and the personal computer via the FX 232AWC H check the following depending on the status of the POWER Lamp of the FX 232AWC H State of POWER Lamp Contents The DC5V power supply from PLC is normally supplied Check the following when it is not possible to commu
7. ult of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN