Home

USER`S MANUAL - RED technology

image

Contents

1. Range 0 91 to 18 288 m Dimensions H P l 142x73x47 mm Weight without 144 6gr battery Laser beam Wattage lt 1mW mW milliwatt Wavelength 650mm nm nanometer Class 2 laser according to EN60825 1
2. measurer for a month or more remove the battery Batteries may spill chemical products that can destroy electronic parts Setting of distance measurer Your distance measurer is sensitive to temperature and humidity changes Before use wait about 15 min to allow it to adjust to room temperature Summary Foot Meter Clear Light Area Volume Memory M1 M2 M3 i _ Measure ON Switching on of the distance measurer For switching on the distance measurer set LD NORMAL OFF located on the side of the distance measurer to LD or Normal position the laser will light up and you can fix the target with the laser point The distance measurer switches off automatically after 4 min For switching off by hand set LD NORMAL OFF to OFF position the laser will black out REMARK When you set LD NORMAL OFF located on the side of the distance measurer to OFF all measures stored in the memory are deleted Measuring 1 If the distance you want to measure is 10 67m or less set LD NORMAL OFF to Normal normal range Otherwise set LD NORMAL OFF to LD long distance range 2 Press the Foot Meter button until the Foot sign appears for a foot measure or the Meter sign appears for a meter measure 3 Keep the bottom of the distance measurer flat against a wall equidistant from the floor to the ceiling Ensure that there is no obstacle towards the point you want to measure and that your head or your hands do not indu
3. to measure the length the width and the height of a room Calculation of area and volume area and volume calculation based on the data measured by you Addition and Subtraction function allows you to add or subtract 2 measures Clearing of memory function allows you to delete quickly all the measures stored Correction of errors the distance measurer indicates that the distance you measure is too long or too short Preparation Installation of battery your distance measurer operates with a 9V battery type 6LR61 not supplied CAUTION use only a new battery of the size and type required Instructions for the installation of a battery 1 Slide the lid of the battery compartment in the direction of the arrow to open it 2 Place the battery in the compartment and over the ribbon as indicated by the markings of the polarity and symbols inside it 3 Put the lid back in place As soon as the low battery warning appears or the distance measurer does not work correctly the battery must be replaced CAUTION Worn out batteries must be disposed of rapidly and cleanly Do not burn or bury them At the end of its travel the laser beam should always encounter a diffuse reflection material examples a wooden plank Class 2 Laser Radiation When open do not stare into the beam Do not direct the beam in the direction of people or animals around you Precautions If you do not plan to use your distance
4. USER S MANUAL CB 1005 ULTRASONIC DISTANCE METER W LASER POINT epg 1 LIQUID CRYSTAL SCREEN oe sll Legg 2 MEASURE IN FOOT OR IN METER a ren uoa uont 3 MEMORY CLEARING 4 SCREEN LIGHTING 5 ji AREA vou STORE ee 5 AREA j j 6 VOLUME 8 M1 M2 M3 7 STORE n g 8 MEMORIES 1 2 3 ware 9 ADDITION OR SUBTRACTION FUNCTION oT 10 MEASURE ON Characteristics Your ultrasonic distance measurer is perfect for real estate agents or building industry professionals who need to know quickly a measure or the area of a room Your distance measurer can measure distances in a straight line from 0 91 m to 15 meters Your distance measurer transmits ultrasonic waves to a point you want to measure Afterwards it measures the time taken by the waves to reflect and then calculates and retranscribes the distance Your distance measurer features With laser point aiming to see the target that one wishes to measure distance Foot Meter function button it allows you to transcribe measures in foot or in meter and to convert a given distance into the type you want Liquid crystal screen on a luminous background you can light the screen thus allowing an easier reading of information even in a poorly lighted environment Automatic stop your distance measurer switches off if you do not press any key during 4 min 3 memories allow you to measure and to store 3 different measures This function is useful if you want
5. ce the distance measurer into error 4 Press the Measure ON key The distance measurer beeps then the distance between the distance measurer and the point you are measuring appears REMARKS The measure appears for about 4 min or more if you press another key ERROR may appear if you try to measure a distance longer or shorter than the range chosen or longer than 18 288m How to carry out a good measurement Some types of curtains and window blinds may absorb waves thus causing inaccurate measurements If you measure the dimensions of a room with curtains open the curtains before measuring the distance between the window and yourself Ensure also that the window is firmly closed If you do not have a direct way free of obstacles between the points you want to measure you will get wrong values due to the waves rebounding on objects such as chairs tables and uneven surface objects If you are not sure that a measurement is correct move slightly to a side and measure once more the distance If the surface of a wall you are measuring is not flat and solid or if you are measuring in a narrow corridor you will get wrong values If that is the case use a solid surface to measure or move from the centre of the corridor To avoid wrong values if you set LD NORMAL OFF to LD ensure that there is no object at 2 5 meters from the point you are measuring except in the case the floor is below a point To measure a distance longe
6. r than 18 288 meters choose a point in the middle of the room for instance from the centre measure the room towards each side and add the two measures Saving a measure 1 Follow the steps in paragraph Measuring for measuring a dimension 2 Press STORE then a memory key Mi M2 or M3 M and the number you choose 1 2 or 3 to locate the memory appears and the measure is stored in the memory 3 If necessary repeat steps 1 and 2 for saving 3 measures 4 To display a measure stored in the memory press memory key M1 M2 or M3 And the measure that you saved is displayed again To delete a stored measure simply enter a new measurement in the place of the older one To clear all the measures stored set LD NORMAL OFF to OFF during at least 3 seconds The distance measurer alarm and the memory figure M that you choose 1 2 or 3 disappear Calculation of volume To find the volume of a room measure the height the width and the length of the room and save each measure in a different memory see Saving a measure then press VOL FEET 3 or METER3 VOLUMEN and the result of the calculated volume is displayed Calculation of area Follow these steps to find the area saving two measures 1 Measure the width and the length of the room and store the values in M1 and M2 see Saving a measure 2 Press AREA M1 and M2 METER2 or FEET2 and AREA and the result of the calculated area appears Add subtract sto
7. red measures 1 Measure 2 dimensions in a room and store the measures in M1 and M2 memories see Saving a measure 2 Press ALL MEMORY CLEAR clearing of memory 3 Press M1 M2 then for adding the measures or Mi M2 then for subtracting them The calculated value is displayed 4 For clearing the display and carrying out another measurement press ALL MEMORY CLEAR clearing of memory REMARK Use of lighting For lighting the display press LIGHT lighting of the screen The display is lighted for about 5 seconds and then it goes out automatically CAUTION For storing your distance measurer for a long period of time Keep the distance measurer dry If it is moist wipe it immediately until it is dry Use and store the distance measurer only in a normal temperature environment Handle the distance measurer carefully Keep the distance measurer away from dust and soil g Wipe the distance measurer with a moist cloth to keep it in good condition Modifying or tampering with an internal component of the distance measurer may cause failure The warranty does not cover this kind of problem If your distance measurer does not work as it should take it to your retailer for inspection Specifications Power supply 1x9V Alkaline type 6LR61 Battery Measure units Foot or Meter Accuracy 0 5 Frequency 40 kHz ultrasonic pickup Working temperature 0 to 43 C