1. USER S MANUAL USB Flash User Backup Recovery User Backup USB Flash v e Download employee s records saved in device to U pen drive e e Press OUT to select User Backup press OK to download the All Rec Backup employee information User Backup e After backup process bar shows 100 press C to exit and back nO User Backup upper menu e The backup file is BAK YG and BAK ZW located in G O0000001 Backup 0 New Rec Backup User Recovery OK 100 Esc C e Upload employee s information saved in U pen drive to terminal e There are two ways to recover employee information 1 Copy BAK YG and BAK ZW to root directory then plug U pen drive into time attendance machine and start user recovery USB Flash 2 Export employee information to U pen drive through U flash gt User Recovery management software then repeat step 1 e Press OUT to select User Recovery press OK to recovery all records e After recovery process bar shows 100 press C to exit and back to upper menu User Recovery Backup 0 User Recovery OK 100 Esc C 25 OO USER S MANUAL System Info n the management interface select System Info and press OK to check the terminal information MENU gt System Info User e Registered user number Maximum 2 000 users System Info FP gt User FP e Registered fingerprint number Maximum 2 000 fingerprint
2. Esc C Next OK Voice Section 01 17 Esc C Sensor LUM 167 Esc C Step 1 Erase All Data Cuntinue Esc C Yes OK Step 2 Check 100 Flash Flash OK Esc C 23 a n USER S MANUAL USB Flash Record Backup Conntected U disk to terminal press M to enter the USB Flash v management menu select USB Flash and press OK New Rec Backup All Rec Backup User Backup New Rec Backup e Download new T amp A records to U pan drive e Press OUT to select New Rec Backup press OK to download the new records e After back up process bar shows 100 press C to exit and back to upper menu e New record file is BAK KQ located in G 00000001 G is the disk name on PC of U pen drive 00000001 is T amp A machine serial number New Rec Backup Backup 0 New Rec Backup OKI 100 Esc C oe All Rec Backup All Rec Backup e Download all T amp A records to U pan drive e Press OUT to select All Rec Backup press OK to download all records e After back up process bar shows 100 press C to exit and back to upper menu e The record file is BAK KQ located in G 00000001 e Prompt if you backup new records firstly recommend to save new record file to local pc Else it will be replaced with all records file Backup 0 All Rec Backup OK 100 Esc C 24 oe
3. Language then press OK Press IN lt or OUT to select the System language then press OK Dev ID e Press C to enter save interface and press OK to confirm Time gt Language ENG Precision e Set terminal fingerprint comparison precision 7 e Q Low 1 Normal 2 High System m j e Select Precision then press OK Press IN lt or OUT to set the precision value and press OK Net 7 e Press C to enter save interface and press OK to confirm gt Precision 1 Volume 4 19 O USER S MANUAL Volumen pa System v e Set the terminal voice volume 0 mute 5 Max Net e Select Volume then press OK Press IN or OUT to Precision 0 set the volume value and press OK to confirm gt Volume 5 e Press C to enter save interface and press OK to confirm 7 Auto off e Set the time duration from the last operation to the dormant System v state gt Auto Off 10 e No Not Off 250 Max Time Auto Update No e Select Auto Off then press OK Press IN or OUT to set NO or auto off time and press OK to confirm e Press C to enter save interface and press OK to confirm Auto update e Auto update means the previous lower quality fingerprint System v template will be automatically replaced by the new higher quality Auto Off 10 one during fingerprint verification gt Auto Update NO e Select Auto Update then press OK Pr
4. if you set a admin in the terminal ID o Admin Setup 008101 No C Yes OK Admin Setup gt ID 008101 Esc C Add OK 16 User Admin Clear Inthe management interface select User Admin Clear press OK e Press OUT to select the admin ID press OK to confirm e The admin ID will be showed on the LCD press OK to confirm e The system prompt whether delete the admin Press OK to confirm deletion e Press C to cancel Notice In the admin delete interface press OK to enter the user ID interface directly then enter the ID to delete admin USER S MANUAL Admin Clear ID 008101 gt ID 008102 Esc C Clr OK Admin Clear D Admin Clear 008102 No C Yes OK Admin Clear gt ID 008101 Esc C Clr OK 17 es USER S MANUAL For Administrator Advanced Functions Set the terminal parameters include system Setting Record Setting Hardware Test and so on 18 a n USER S MANUAL Setup System In the management interface select Setup System then press OK to enter the sub menu System v gt Dev ID Dev m SOROEN Time erminal s serial number Language ENG Time e Set system time time format displays as YY MM DD H M l e Select Time then press OK Time MON e Press OK to change the date and time one by one 11 17 2011 12 06 e Press C to enter save interface and press OK to confirm e Set language e Select
5. numbers and press OK to confirm Esc C Set OK Input password again and press OK to confirm Enroll Press OK to save password ons FP 1 2 ES Cara e Press C to exit to Enroll interface to continue or press C to back to Esc C Set OK defult interface g n Pass Enroll PwD Ra Esc C Set OK Pass Enroll PwoID Sy Confm wanes Pass Enrol 008101 P Cancel C Sav OK k m 12 USER S MANUAL User Enroll Card Enter Menu select User and press OK to Enroll interface Enroll tti i is S nro Input employee s ID and press OK to register employee ID 008101 e Press OUT to select Card and press OK to enroll Esc C Set OK e Swipe the employee s card and the system will get card number and enter save interface Enroll e Press OK to save password ij Password i Esc C Set OK Press C to exit to Enroll interface to continue or press C to back to defult interface i Card Enroll Punch Card Card Enroll 008101 C Cancel C Sav OK 13 User Delete When employees resign we need delete the employee s information in the terminal Enter the management menu Select User Delete press OK Enter the employee s ID and press OK the system will prompt again whether to delete press OK again to confirm delete the employee information Continue to delete other employees after deleting successfully or press C to back to the defau
6. USER S MANUAL Neo connect PLUS Biometric Terminal for T amp A and Access Control I BioNANO Algoritmo Core Fingerprint E gt Easy Way biometrics Wwww easywaybiometrics com FEATURE USA TI 300MHz high speed processor USA BioNano core fingerprint algorithm of high speed and stability New generation fully sealed waterproof and dustproof fingerprint sensor User name display and human voice prompt Realtime data transfer and WEB online tracking Standard USB USB pen drive and TCP IP Identification method FP ID FP D PW Fingerprint capacity 2000 Record capacity 50000 Identification speed lt 0 5 second Size 200mMm w 140mm h 38mm d USER S MANUAL Contenido SAFETY PRECAUTTONG eet eens eee E ee ee ee ee ee ee eee eee 4 OSS A erase esses vec eae hoe E E E E A E asad E AEA E A A N E T 5 Illustration for placing fingerprint 0 cece ccessecesseecsscessecessecesseecssecesseccseecessscesseceasecsssecessecsatecssesenseess 6 PPPE NCE r E E ET E E A 7 SPESE AR E E EEN E EE E E EE E E E E mania ete seocpoe 9 User Enroll Fingerprint cede ante atinc ns ioeaniedaaretasieeneae nun teasstanosaeae aaeteapauenddeceansstaiasdulerdutesteiuae nieces 11 WS SEO Wt CE SS SV OO ara N E A E O E E EN 12 Sce EEE o h P arcsec sedis I E E I E A E ET E 13 Jeor DETO e eer E ee E EE A E ee E ER 14 NS SST MOOG eoar N TEA E EE 15 Uer AN S E U e a EEA EE EAE E EEE OE E A 16 Doce eE E E E A T E EAE E N E E 17 BS A p E E A
7. admin can add or delete the users and the admin also can change the system settings of the terminal 1 1 Identification e If it is 1 1 identification mode the user has to input the user ID firstly then verify the fingerprint or enter the password to make identification In this mode the fingerprint sensor on the fingerprint template will identify with the one of the special user ID 1 N Identification e Under 1 N mode the user need not enter any user ID J ust need place the fingerprint on the fingerprint sensor The terminal will automatically identify this fingerprint with the ones of all users registered in inside database Fingerprint Enrollment e It is the process to capture the fingerprint image features got from the fingerprint sensor and save the inside memory into the terminal USER S MANUAL Illustration for placing fingerprint Correct method Straighten finger and place it flatly on the sensor and make the fingerprint maximally cover the sensor Place finger in the center of the sensor Place finger flatly and smoothly on the sensor Incorrect method Place finger away from the center of the sensor rocess of tip process on Appearance Front State Key Clock In Page Up State Key Clock Out Page Down WorkCode Setup Key LCD LED Fingerprint Sensor Menu Key Enter the System Management menu Speaker Operation with voice prompts Cancel Key Exit Cancel the present oper
8. ation Confirm Power Key Confirm the present operation Power On Off key O 9 Num Keys To enter employee ID or password Back USB connection slot TCP IP connection slot U disk interface USER S MANUAL SST TE For Administrator Basic Functions Manage employees information Main functions Register users delete users add delete admin and so on a USER S MANUAL System Menu Please press M to enter system management menu under initial state Since anyone can enter the terminal s management menu under iN initial state by pressing M we suggest you set the admin shortly after installation of the 09 00 56 terminal 10 11 17 WED The method of registing admin is the same for common a employees Please refer to User Enrollment and Admin Setup instructions Verify the admin to enter the system management menu There are three ways to verify admin 1 Fingerprint verification Let the person who is expected to be Admin IN the admin place his her finger E on the sensor to verify 09 00 26 2 Password verification Enter the admin s ID and password 40 11 17 WED press OK to confirm Enter the system management menu after the admin verification is successful 3 Card verification Swipe the admin s card to verify If the admin verification is ok it will enter the system MENU management menu gt User Setup USB Fla
9. enc E A AEI O EAE E 19 SCUD yV EONA a a E A E A A ET EOE EO E EENE OE EN 21 SUD IO o TUD aer e RTE EE E E E E 22 SSR Pree Ware TO Eene E E E A T EAE A E N NE S 23 USB Flash Record Ba KUD enro aE E NENOS 24 USB Flash User Backup Recoverfy sssssesereerissresrssressrssrrssrssrrrsrresressrasressrsssrtsriesressresressreesresreesrrsreesres 25 N O L O Ree E E E AE EE E E EE A T EAE E A AEE E E 26 USER S MANUAL USER S MANUAL SAFETY PRECAUTIONS e Please read it carefully first of all e Don t install the terminal under direct light humid dusty or sooty environment e Don t install the terminal near the magnetic field e Don t install the terminal near the calefaction device e Don t sprinkle the liquid water drink chemistry on the terminal e Always keep the surface of the terminal clean e Clear the terminal by towel when there is water on the surface e Don t break the terminal e Don t press two keys at the same time e Don t take down repair or change the terminal without authorization e Don t allow children to touch the terminal e This terminal is only used for fingerprint verification don t use it for other purposes e If in doubt please contact the local distributor USER S MANUAL Glossary Administrator e It is a special user who has the authorizations of setting the terminal system settings and user information The
10. ess IN or OUT to select Yes or NO and press OK to confirm e Press C to enter save interface and press OK to confirm 20 USER S MANUAL Setup System Net Enter the system management menu Select Setup System Net Press OK to enter the sub menu Net v gt IP Address This function main includes IP Address Subnet Mask MAC Address Ta and Gateway IP settings MAC Address Press OUT to select IP Address or Subnet Mask or MAC Address or Gateway IP l IP Address Press OK to enter modify interface IEP 168 000 218 Press OK to select the parameters and press IN lt or OUT or number key to modify L Press C to enter save interface i Subnet Mask Press OK to confirm and return to the Net menu Pt 255 255 000 Set C Next OK MAC Address WE 247 188 066 084 215 Set C Next OK Gateway IP Ey 168 000 001 Set C Next OK 21 Setup Log Setup USER S MANUAL In the management interface select Setup Log Setup then press OK to enter the sub menu Log Alert The terminal will alarm when the memory capacity is less than the Log Alert value No Not alarm Max value 5 000 Select Log Alert then press OK Press IN set NO or input the warning records value and press OK to confirm Press C to enter save interface and press OK to confirm or OUT to Re Verify Se
11. lt interface Notice Please caution with the action All deleted information including employee s fingerprint password attendance records can not be recovered If deleted by mistake please connect with the PC and upload the employee information which has been backuped before to recover the employee information USER S MANUAL User v Enroll gt Delete Verify Mode Delete D 008101 Esc C Set OK Delete 008101 No C Yes OK 14 RNN User Verify Mode Enter the management menu Select User Verify Mode press OK User to enter the setting interface Enroll Delete e Press OUT to select employee or press OK to input user ID gt Verify Mode e Press OK to enter setting interface 4 Verify Mode e Set employee s verify mode through OUT there are three modes ANY PW FP and ID FP e Then press OK to save this setting acai dati Verify Mode ID 008101 Esc C set OK Verify Mode 008101 Verify Mode 008101 PW FP Cancel C Sav OK 15 USER S MANUAL User Admin Setup Admin Setup n the management interface select User Admin Setup press OK Press OK to enter the admin user ID and press OK to confirm the Esc C Add OK system will prompt whether to set user as admin Press OK to confirm and press C to cancel t asks for the admin verification before entering the system management menu
12. nt menu will automatically return to the default menu if no operations in a certain period 10 User Enroll Fingerprint Enter the system management menu Select User Enroll Press OK to enter the enroll menu Enter employee s ID and press OK to register employee e Press OUT to select FP 1 or FP 2 Press OK to start fingerprint enrollment Press OK to save and return to the enroll menu Place finger on the sensor correctly Please refer to lt The way to enroll a fingerprint gt You need to enroll one fingerprint twice Please enroll fingerprints according to LCD prompt If the second fingerprint enrolled is different from the first one or the way you place finger is incorrect it will prompt Please try again If the fingerprint is existed it will prompt Fingerprint repeated Please enroll another fingerprint You can continue to enroll employees one by one Or press C to exit USER S MANUAL User gt Enroll Delete Verify Mode Enroll ID 008101 Esc C Set OK Enroll FP 2 Password Card Esc C Set OK Enroll Place Finger 1 008101 1 Cancel C Sav OK 11 Sinn User Enroll Password Enter Menu select User and press OK to Enroll interface Enroll Input employee s ID and press OK to register employee Press OUT to select Password and press OK to enroll ID 008101 Input password 1 to 6
13. s Log e Press OK to view the number of users who registered a password System Info v Log User 1000 e The time attendance logs Maximum 50 000 records gt Password 500 Log 15000 Firm Ver e The firmware version System Info A gt FirmVer b1 15 00 Press C back to the management interface 26
14. sh System Menu USER S MANUAL Menu list User for example Enroll Delete Verify Mode Admin Setup Admin Clear Setup System Log n Setup and Hardware Verify Mode Test Admin Setup Mme IPAddress System includes system ye time language network ea Nett H parameter fingerprint verification precision system Gateway IP voice volume dormancy time tetera Auto Updat Log Setup includes clock Sp Auto Update _ in out records storage alarm and fingerprint repeat clock in out time period Keypad LCD Voice Sensor Flash Hardware Test includes keypad LCD voice fingerprint sensor flash test USB Flash Use the U disk for communications USB Flash New Rec Backup All Rec Backup User Backup include New Rec Backup All Rec Backup User Backup and User Recovery System Info Show existing users amount fingerprints amount records amount firmware version system Info User FP Log FirmVer Press IN lt or OUT gt to select a corresponding submenu and press OK to confirm Enter submenu press IN lt or OUT to select different options for setup e After setup press C turn to save submenu Press OK to save or press C to cancel and either of the operation will return to the previous menu Press C to exit the system management menu e To ensure safety the system manageme
15. t a period during which time the system only save the first successful records and do not save the repeated records No Disable the function Max value is 250 min Select Re Verify then press OK Press IN or OUT set NO or enter the value and press OK to confirm Press C to enter save interface and press OK to confirm to Log Setup gt Log Alert 1000 Re Verify NO Log Setup gt Log Alert Re Verify Log Setup Log Alert 3000 gt Re Verify NO Setup Save No C Yes OK 22 Setup Hardware Test In the management interface select Setup Hardware Test and press OK to test Keypad LCD Voice Sensor and Flash Keypad e Test the keypad e Select Keypad and press OK e Press any key on the keypad If LCD shows the same the keypad is good e Test the LCD e Select LCD and press OK e Press OK to start test Voice e Test the terminal voice e Select Voice and press OK e Terminal auto tests 1 17 voices Sensor e Test the sensor s luminance e Select Sensor and press OK e The luminance value will be changed according to the environment e Test the terminal flash memory e Select Flash and press OK e Notice This test will delete all the data in the flash memory and then check it e Please backup the data before this operation USER S MANUAL Hardware Test v gt Keypad LCD Voice Keypad Current Key 3 Esc C