1. 5 The PX3004 supplies sufficient DC power for the terminal s internal charger Insert a NEO terminal in the docking station When installed in the docking station the terminal s battery charge LED will illuminate to indicate applied external power and may charge the internal battery During charge the terminal LED will be a slow flashing green or solid yellow depending on the charge progression Flashing green indicates a preliminary charge state Yellow indicates ongoing charge e When the battery capacity reaches 95 the LED turns solid green 3 2 Ethernet Connection Ethernet connection will be made when The NEO terminal is in the docking station e The docking station is powered by the Power Adapter e The docking station is connected to Ethernet network using a Category 5 cable plugged into the RJ45 rear socket The rear mounted RJ45 connector incorporates a green Link LED that flashes to indicate the presence of data traffic The yellow Speed LED is steady ON when the network is 100 Mbps and OFF when the network is 10 Mbps See figure 3 1 page 5 4 Psion Teklogix PX3004 User Manual Figure 3 1 Quad Docking Station Rear View and Power Adapter Green Power LED Mini Fit Jr Input Receptacle Mini Fit Jr RJ45 Ethernet with Green Red Link LEDs Green Power LED AN important The Ethernet connection is for indoor use only Psion Teklogix PX3004 User Manual 4 Cleaning The PX3004 A Tmporant D
2. PX3004 NEO Handheld Computer Quad Desktop Dock and Charger User Manual PN 1081342 A ISO 9001 Certified Quality Management System Psilon TeKLoc x Copyright 2008 by Psion Teklogix Inc Mississauga Ontario Canada This document and the information it contains is the property of Psion Teklogix Inc is issued in strict confidence and is not to be reproduced or copied in whole or in part except for the sole purpose of promoting the sale of Psion Teklogix manufactured goods and services Furthermore this docu ment is not to be used as a basis for design manufacture or sub contract or in any manner detrimental to the interests of Psion Teklogix Inc Return To Factory Warranty Psion Teklogix provides a return to factory warranty on this product for a period of twelve 12 months in accordance with the statement of War ranty and Product Support provided at www psionteklogix com warranty The warranty on Psion Teklogix manufactured equipment does not extend to any product that has been tampered with altered or repaired by any person other than an employee of an authorized Psion Teklogix service organization See Psion Teklogix terms and conditions of sale for full details Important Psion Teklogix warranties take effect on the date of shipment Service Psion Teklogix provides a complete range of product support services to its customers For detailed information please refer to Support Services amp World
3. ce if the cable is suspect Contact your network administrator 5 4 RJ45 Yellow LED is OFF When Connected to an Active 100Base T Network Check the Category 5 Ethernet cable that connects to the rear Ethernet connector on the Quad Dock see Figure 3 1 on page 5 Replace if the cable is suspect Replace if the cable is suspect Contact your network administrator to ensure the network is running at 100 Mbps 5 Power LED Remains OFF Check the AC cable Replace with the same type if you see signs of wear or fraying Check the Power Adapter LED If the power LED is Off the power adaptor may be defective and require service If the Power Adapter LED is On check the Quad Dock power LED If the power LED stays OFF the PX3004 is defective and requires service Psion Teklogix PX3004 User Manual 6 Support Services amp Worldwide Offices Psion Teklogix provides a complete range of product support services to its customers worldwide These services include technical support and product repairs 6 1 Technical Support For technical support in North America Call Toll free 1 800 387 8898 Option 3 or Direct Dial 1 905 813 9900 Ext 1999 Option 3 For technical support in EMEA Europe Middle East and Africa please contact the local office listed in the website below http www psionteklogix com EMEA Support For technical support in Asia please contact the local office listed in the website below http www psiontek
4. gs on the Quad Dock and Power Adapter The PX3004 shall be used to charge only the Handheld Computer and batteries recommended by Psion Teklogix The Power Adapter shall comply with National safety regulations of the country where the equipment is to be used e Use of an attachment not recommended or sold by manufacturer may result in fire electric shock or personal injury To reduce risk of damage to the electric plug and cord when unplug ging the charger pull the plug rather than the cord e Make sure the cord is positioned so that it is not stepped on tripped over or otherwise subjected to damage or stress Do not operate the PX3004 or Power Adaptor with a damaged cord or plug Replace immediately e Do not operate the PX3004 or Power Adapter if it has received a sharp blow been dropped or otherwise damaged in any way it should be inspected by qualified service personnel e Do not disassemble the PX3004 or the Power Adapter it should be repaired by qualified service personnel Incorrect reassembly may result in electric shock or fire Psion Teklogix PX3004 User Manual 1 To reduce risk of electric shock unplug the Power Adapter from the outlet before attempting any maintenance or cleaning e Do not expose the Power Adapter or PX3004 to rain or snow e An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in fire or electric shock If an exten
5. iron ment The Restriction on Hazardous Substances Directive RoHS pre scribes the maximum trace levels of lead cadmium mercury hexavalent chromium and flame retardants PBB and PBDE that may be contained in a product Only products meeting these high environmental standards may be placed on the market in EU member states after July 1 2006 RoHSV RoHS Logo Although there is no legal requirement to mark RoHS compliant products Psion Teklogix Inc indicates its compliance with the directive as follows The RoHS logo located either on the back of the product or underneath the battery in the battery compartment or on a related accessory such as the charger or docking station signifies that the product is RoHS compli ant as per the EU directive Other than as noted below a Psion Teklogix product that does not have an accompanying RoHS logo signifies that it was placed on the EU market prior to July 1 2006 and is thereby exempt from the directive Not all accessories or peripherals will have a RoHS logo due to physical space limitations or as a result of their exempt status Disclaimer Every effort has been made to make this material complete accurate and up to date In addition changes are periodically added to the informa tion herein these changes will be incorporated into new editions of the publication Psion Teklogix Inc reserves the right to make improvements and or changes in the product s and
6. logix com Technical Support for Mobile Computing Products is provided via e mail through the Psion Teklogix customer and partner extranets To reach the website go to www psionteklogix com and click on the appropriate Teknet link on the home page Then click on the Login button or the Register button depending on whether you have previ ously registered for Teknet Once you have logged in search for the Support Request Form 8 Psion Teklogix PX3004 User Manual 6 2 Product Repairs For repair service in North America Call Toll free 1 800 387 8898 Option 2 or Direct Dial 1 905 813 9900 Ext 1999 Option 2 For repair service in EMEA Europe Middle East and Africa please contact the local office listed in the website below http www psionteklogix com EMEA Support For repair service in Asia please contact the local office listed in the website below http www psionteklogix com 6 3 Worldwide Headquarters Psion Teklogix Inc 2100 Meadowvale Blvd Mississauga Ontario Canada L5N 7J9 Tel 1 905 813 9900 Direct 1 905 813 9900 Fax 1 905 812 6300 Psion Teklogix PX3004 User Manual 400217
7. o not immerse the unit in water Dampen a soft cloth with mild detergent to wipe the unit clean e Use only mild detergent or soapy water on a slightly damp cloth to clean the PX3004 Avoid abrasive cleaners solvents or strong chemi cals for cleaning The plastic case is susceptible to harsh chemicals The plastic is partially soluble in oils mineral spirits and gasoline The plastic slowly decomposes in strong alkaline solutions e To clean ink marks from the label use isopropyl alcohol 5 Troubleshooting 5 1 The NEO Terminal Charge Indicator is OFF When Docked When a NEO terminal is docked into a powered PX3004 and there is no charge indication on the NEO LED there could be a problem with the NEO terminal or with the docking station Use a NEO terminal with a properly functioning charge indicator to isolate the problem 5 2 The NEO Terminal Charge Indicator Rapidly Flashes Green If the NEO terminal charge indicator is flashing green fault e Remove the NEO terminal and disconnect the adaptor DC power cable e Wait at least 20 seconds and then plug the cable in again e Insert the NEO terminal in a PX3004 dock If the NEO charge indicator still shows a fault the terminal requires service 6 Psion Teklogix PX3004 User Manual 5 3 RJ45 Green LED is OFF When Connected To an Active Network Check the Category 5 Ethernet cable that connects to the rear Ethernet connector on the Quad Dock see Figure 3 1 on page 5 Repla
8. or the program s described in this document without notice and shall not be responsible for any damages including but not limited to consequential damages caused by reliance on the material presented including but not limited to typographical errors Table Of Contents 1 Safety Instructions for the PX3004 and Power Adapter 1 2 PX3004 Introduction 1 0 0 eee eee ee 3 2 1 Operator Control saser cosranr ereke widtuanuatalgcn sy DAE 3 2 2 Indicato s ge uaiiie te a a aa 3 3 PX3004 Operation 000 002 erta aia aii ae 4 3 1 Docking the NEO Terminal 0 00 naana 4 3 2 Ethernet Connection 6 occc civic cen one EN wh eee 4 4 Cleaning The PX3004 0 0 cece eee 6 5 Troubleshooting sc cc csccedaiais sence eae eee ee sa 6 5 1 The NEO Charge Indicator is OFF When Docked 6 5 2 The NEO Charge LED Rapidly Flashes Green 6 5 3 RJ45 Green LED OFF Connected to an Active Network 7 5 4 Yellow LED OFF Connected 100Base T Network 7 3 5 Power LED Remains OFF avse erent ETOC aE eens 7 6 Support Services amp Worldwide Offices 8 6 1 Technical Support saiae nee eee 8 6 2 Product Repairs 5 6 sic sce be ek 4 a bo eS ee 9 6 3 Worldwide Office 0 0 6 cc ccc eens 9 1 Safety Instructions for the PX3004 and Power Adapter N Important Use the Power Adapter specified or recommended by Psion Teklogix e Before using the PX3004 read all instructions and cautionary markin
9. sion cord must be used make sure 1 The plug pins on the extension cord are the same number and shape as those on the power adapter 2 The extension cord is properly wired and in good electrical condition and that the wire size is larger than 16 AWG e PX3004 storage temperature is from 30 C to 60 C 22 F to 140 F Operating humidity and temperature is 5 95 non condensing and 0 C to 40 C 32 F to 104 F e The Ethernet connection is for indoor use only 2 Psion Teklogix PX3004 User Manual 2 0 PX3004 Introduction The PX3004 Quad Dock and Charger with Power Adapter Figure 2 0 is a desktop model designed to accept as many as four NEO terminals The PX3004 station powers the docked NEO terminals and their internal battery charger The PX3004 also connects a 10 100 Base T Ethernet network to the docked NEO terminals Figure 2 0 PX3004 Quad Docking Station and Power Adapter 2 1 Operator Controls The PX3004 has no operator controls or power switch 2 2 Indicators The PX3004 has two rear Ethernet LEDs and one power LED on the top left hand comer of the product The Power Adapter also has a power on off LED See figure 3 1 page 5 Psion Teklogix PX3004 User Manual 3 PX3004 Operation 3 1 Docking The NEO Terminal Insert the Power Adapter Mini Fit Jr plug into the PX3004 rear DC input receptacle The PX3004 Power LED and Power Adapter LED will glow green when powered from the mains See figure 3 1 page
10. wide Offices on page 10 This section also provides information about accessing support services through the Psion Teklogix web site List of Approvals North America EMC FCC part 15 subpart J class A Europe EMC and Low Voltage Directives This equipment complies with the essential requirements of EMC Direc tive 2004 108 EC and Low Voltage Directive 72 23 EEC CE E Mark When used in a residential commercial or light industrial environment the product and its approved UK and European peripherals fulfill all requirements for CE marking Declaration Of Conformity Declaration of Conformity Documents are provided at www psionteklogix com DoC gt Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC This Product and its accessories comply with the requirements of the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC If your end of life Psion Teklogix product or accessory carries a label as shown here please contact your local country representative for details on how to arrange recycling For a list of international subsidiaries please go to http www psionteklogix com EnvironmentalCompliance Restriction On Hazardous Substances RoHS Directive 2002 95 EC What is RoHS The European Union has mandated that high environmental standards be met in the design and manufacture of electronic and electrical products sold in Europe to reduce hazardous substances from entering the env