1. DARANE bok AL Eat Pra tot oF MODE aF F p p tot CFL I kg 1 bokAL E E P MODE TOTAL in SUM OD ig TOTAL 0 E fue TOTAL The function allows calculating total weight for series of measurements which can be greater than scale capacity It allows calculating total weight as well as average value Press MENU key When totAL is displayed press T lt key The following options will appear successively tot report printout without clearing total register tot oFF clearing total register report printout and leaving the function tot working with receipt printout after each measurement tot working without receipt printout tot CFG saving measurement mode using C key Manual after taking off the load auto Press T lt key when tot O is displayed Perform measurement series by pressing i key for storing results into total register In order to print and display results enter the function by choosing fotAL and tot option from menu The results are displayed sequence total weight SUM number of registered measurements average value regarding that moving to display successive result is performed after pressing E gt key Attention In scales with LED display SUM sign is replaced
2. NEL nonE no control ky H d x Odd nonparity MODE Even parity control kes E 5 scale number in network nr if the scale doesn t work in network the number PR m transmission through serial interface Send nG StAb transmission after key is used and result is stable noStAb transmission after key is pressed without need of stabilisation Auto automatic transmission after load is put on and result is stable Auto Cont continuous transmission about 10 results per second Cont Remove transmission after removing load Default parameter values Long 9600 bps 8 bits none StAb SCAnn cooperation with MJ 4209 barcode readers ON OFF i GE nd lel Bur x MODE SL Hnn In order to set needed parameters choose SErIAL function select appropriate parameter and press T key when required option or parameter value is displayed In scales with an additional serial port appear Port 1 and Port 2 for the independent setting of both ports 40 USER MANUAL 17 5 Printout configuration Print MAXIS SE UP Par k 5 MODE Pork _ HERdE td Pen oa Pr ad ld x L ut n n x nEkto BARE otf nr LLd MODE Function is used for printing additional information stored in scale memory weighed product identification dat
3. BA M BA N BA H BA NK USER MANUAL BA BA N BA M BA NY FILE 2015 03 18 BA 146 bC0101 GB AXIS 80 125 Gda sk ul Kartuska 375B 2 USER MANUAL Contents 1 General description rero eene de radere io are a n v 3 2 u it n ditti enc t diode e e Lei e diva e e he e re eg 5 3 Coripleleress rai eee terrre ae 5 4 Technical dala e cete dc en i rh unite ei c rh gd 6 5 Security rules tr nte rp itn err phe rae er pea n e ag 12 6 Scale external outputs ro teer iet eo tat er ete e n rn e tein ea 13 6 1 Connecting a computer printer or label printer sss ener tenete tentent 15 6 2 Detailed onG protocol description ort ra PED MAR PARE aaa 16 6 3 Detailed EPL protocol description sse nente tentent tette tette ttt ntt tete 18 T Preparation ob WOIKDIaCe pe rrt na cr S 19 8 Preparation lo ro ona dai Rendite du e erede don 20 9 Balance checking and adjustiment oorr rr HG REP EEUU FG HU PEOR GR 21 10 Accumulator change in aluminium meters neret ttti tetti EA 22 11 General rules OF using scala Et d o FH HU Rin eode 23 12 Scale with ME 01 meter keys and indicators I I U tentent tnter nna 24
4. Menu first position is displayed for about 7s During this time user can view next positions by using key or 0 Immediate out to previous menu level is done by using Menu key 30 USER MANUAL Ae 93 8 es pal L m 4 69 ca ure re 100 E 7 Z f S bel cas h FTE i 90 mud oz AHAAA m t3 key working method During standard weighing t key is used to switch between net and gross indication When special function e g PCS is turned on using key enables to go back to standard weighing mode Sign o on the left side signalizes that special function is turned on and user can go back to function mode by pressing key USER MANUAL 3l 30 md MODE HR key working method During normal weighing temporary 5s readout resolution increase is possible Return to normal indication is made automatically Inscribing numerical values Inscribing numerical values is needed in some special functions e g fArE function requires to inscribe tare values Keys 0 lt increasing digit value gt decimal point T next digit position MENU end of inscribing 32 USER MANUAL Menu diagram MENU key PCS totAL SEtUP out AutoZEr personalized function menu created u
5. sis 2127 PLUS Burr both Y 77 44 USER MANUAL 17 8 Entering reference zero value ZErO Note This function is enabled in non legalized scales only ZEr0 function allows entering new value of reference zero value referred to empty pan without need of contacting with authorised service centre MAXIS l 30 mdi 00 DERESE h re Press MENU key When ZErO is displayed press T lt key On the display a sign ZEr Cod will show up momentary and the a dash on last digit position To enter code in new scale 1234 use keys 0 lt increasing digit m T next digit l L P m MENU end of inscribing The following options appear successively on display mi E r az I ZEr Cod enter new secure code value ZEr SEt enter new zero value MODE ci m L L d Using T lt key choose ZEr SEt Direct result from A C converter will appear on scale display When the pan is empty press 0 lt key Wait for finishing zeroing process MODE In order to change access code use ZEr Cod option as mentioned earlier MODE I gi unL OAd dEr rod 2234 USER MANUAL 45 18 Special functions description All scales besides basic metrological functions weighing and taring have a set of special functions Depending on meter type functions set diff
6. activate the function thr check last threshold values press key several times thr CFG choose Relays socket mode IMPULS Batching mode SIGNAL Indication mode out Choose thr on option using T lt key The following options for entering thresholds are displayed SEt LO set lower threshold value SEt HI set upper threshold value SEt ZEr set zero signalisation threshold Using T lt key select SEt LO option Set lower threshold value using the following keys 0 digit increase decimal point T move to next digit MENU _ finish Then select SEt H option and enter upper threshold value Choosing SEt ZEr signalisation option will enter zero Choosing out will end inscribing thresholds Choosing again out will start thr function To change Relays socket mode use thr CFG option Default option is Indication To leave the function press MENU key and then choose fhr and thr oFF options 62 USER MANUAL Relays connection diagram gnd shield Relays output is the open collector transoptor output with load capacity 25mA 24V Transmitter inputs must be protected with diodes e g 1N4148 It is advised to use MS3K P electronic board sold separately consisting of RM96P transmitters with DC24V input voltage and AC250V 3A output Important notes 1 After switching the scale on both thresholds are set to maximum values 2 When setting upper
7. tAr SEt enter tare value with keys 0 L gt gt T and MENU out printout a setting value of tare Press T lt key when tAr SEt is displayed By pressing 7T key choose proper memory cell where tare will be stored tAr 01 02 10 Choose inscribing method MANUAL inscribing using keys 0 D gt T and MENU Pan inscribing mass value that is on the pan After storing tare the scale starts working with inscribed tare value Note Tare value is stored in memory also after unplugging the scale from the mains USER MANUAL 55 Weighing with constant tare TAXIS 90 mud IM 3 ges LA EAr al F Ehe on x mam tAr SEE In order to use tare value that is located in memory choose from menu tArE function and then tAr on option A list of memory cells will show up tAr 01 02 10 Cells with inscribed value are marked with o sign on the left side active value marked with A ATTENTION In scales with LED display cells with inscribed value are marked with Choose proper memory cell using T lt key tArE function is activated with chosen tare value Moreover the scale will indicate nett weight weight on the pan minus tare values Using key or 0 while empty pan causes scale zeroing and then substraction of recalled tare Minus i
8. 230V 50Hz 8VA 12V 500mA Internal supply er option NIMH AA size 4 pcs only LCD version Working time with mm m about 6 h with display backlighting about 16h without backlighting Scale weight 2 5kg 2 8kg 3 5kg p EC verification Y A A A x70mm x70mm x80mm x110mm x70mm x70mm Base with column dimensions 250x400mm 300x440mm 300x440mm Scale with column height 400mm 415 415 increased readability for non EC verification applications Max d and e for double range scales are situated in appendix A USER MANUAL y BA popular platform scales cont Scale type BA15 BA30 BA60 BA150 BA300 BA15K BA30K BA60K BA150K BA300K ASAGABA Platform A5 A6 A8 A10 Maximal load Max 15kg 30kg 60kg 150kg 300kg Readout unit d 5g 50g 100g 1g 10g 10g 9 Verification unit e 100g Minimal load Min 100g 200g 400g Tare range x UAM oU Accuracy class 10 40 C Working temperature 15kg 30kg 60kg 150kg 300kg 0 0 ee Weighing time 3s 3m only K version 230V 50Hz 8VA NIMH AA size 4 pcs only LCD version Working time with n m about 6 h with display backlighting about 16h without backlighting EC verification Platforms e 4 Platform dimensions 400x400x120 400x500x120mm 600x500x135mm Base with column 800x960mm d
9. 64 USER MANUAL 18 12 Radio communication channel choice function rF CHn Function enables choosing radio communication channel between the scale and a pilot In scale and in pilot the same radio channels must be chosen Function should be used when communication is disturbed by other devices that use the same communication channel 30 mdi OD kg AAAA es e MODE rr Ha o LHn MODE D t ILU Hn MODE 02 Hn MODE I 30 h LIL kg Press MENU key and choose rF CHn by pressing T key The following communicates will appear on display Na wy wietlaczu pojawi sie kolejno CHn 01 channel 1 CHn 02 channel 2 CHn 16 channel 16 out out without changing channel In default setting channel 01 is on USER MANUAL 65 18 13 Charging accumulators function bAttErY option AXIS na kg BISIESIEISIS bALLErY m bt FF bit on z bAk Uol bAttErY function allows switching on or off charging accumulators during work with feeder and checking their power level The function has the following options bAt OFF charging off option required if ordinary batteries are used bAt on charging on accumulators are being charged even after switching scale off using 1 key bAt VoL reading power level of accumulators in 96 go b
10. A measurement is performed in two phases first phase single piece weight calculation on the basis of defined pieces amount 5 10 20 50 100 200 or 500 pieces Second phase pieces counting First phase options PCS recalling of a value inserted earlier this quantity must be inscribed earlier PCS SEt set any amount of pieces in a sample PCS APW set unitary mass directly PCS rS inserting number of details in a sample and receiving of their mass from other scale connected by RS 232C It is advised that single piece weight is not less than one reading unit and sample weight used in first phase is bigger than 100 reading units To leave function press MENU key and then using T key chose PCS and PCS oFF I Note APW too LOW communicate signalises that a sample was not put on the pan or if single piece weight is less than one tenth readout plot counting is not possible APW LOW communicate signalizes that single piece weight is more than one tenth but less than one readout plot counting possible but with bigger errors result blinks In scales equipped with LED display pcs sign is replaced with USER MANUAL 31 18 3 Percentage weighing function PErC 100 5 Note E 20 md Tig PE TR 0 40 0 i d E 106 on This function
11. BA3MX BA6MX BA15MX BA15X BASMKX BA6KX BA6MKX BA15KX i BA15MKX BA30X BA30KX BA60X BA60KX BA150X BA150KX BA300X i BA300KX BA60EX BA150EX BA1 5NX BA3NX BA6NX BA15NX BA3ONX BA60NX BA150NX BA300NX BA1 5NKX BA3NKX BA6NKX BA15NKX BASONKX BA60NKX BA150NKX BA300NKX BA1 5HX BA3HX BA6HX BA15HX BA30HX BA60HX BA150HX BA300HX BA1 5HKX BAeHKX BA15HKX BA30HKX BA60HKX BA150HKX BA300HKX BA6MY BA12MY BA60Y BA120Y BA6KY BA12KY BA60KY BA120KY BA6NY BA12NY BA60NY BA120NY BA6NKY BA12NKY BA60NKY BA120NKY marked with CE mark comply with the following 1 Directive 2004 108 EWG electromagnetic compatibility and harmonized norms EN 61000 4 3 A1 2008 A2 201 1 EN 61000 6 3 2008 1 2011 2 Directive 2006 95 WE low voltage and harmonized norm EN 61010 1 2004 USER MANUAL 73 Moreover scales with the following markings on the name plate C 5 the number of the Notified Body responsible for EC verification 1443 two digit number of the year of EC verification a green metrology sticker with M mark a protective seal affixed by the Notified Body comply with the requirements on the Type Approval Certificate WE No T7950R0 and are verified to comply with EN 45501 1999 Additional information Conformity evaluation for the Directive 2006 95 WE and 2004 108 WE was
12. mentioned above After that push key when SIA o is displayed Put on successive objects on the pan remove after indication stabilization in order to add them to measurements register In order to obtain printed statistical results from measurements series press MENU key and T key when StAt is displayed and later StA After printout two options are enabled rESET erasing results Contin continuation USER MANUAL 69 Pressing E key printouts estimated values and histogram STRTISICS Nominal nominal value RONINRL 58 088 3 Tolerance accepted value in percentage TOLERANCE 188 X HO 98g N number of sample IN TOL number of samples in toleranc NO SRMPLE TOL NOM TOL 18 887 it 28 125 3 28 126 3 36 285 3 38 284 3 38 281 48 597 3 TOL amount of measurements under allowable lower value TOL amount of measurements above J od allowable upper value TOTAL sum of weights of all n samples AVERAGE average weight as Total n MIN minimum weight in n samples H 25 IN TOL 23 TOL a MAX maximum weight in n samples gt TOL TOTAL 1264 664 8 AVERAGE 38 587 2 ST DEV standard deviation HAX 91 131 3 18 887 HRX MIN 81 124 3 ST DEU 26 6488 ST DEV standard deviation percentage 3T DEU Z 48 82 To finish work with this function and zeroing result register press MENU
13. 100 USER MANUAL 25 LED display version zero Stabilization net weight weight metrological indicator indicator indicator result data MAXIS Ma d scale keys SWitch on switch off standby gt Te tare menu position confirmation next digit when inscribing i Me zeroing scrolling menu increasing digit when inscribing result printout decimal point when inscribing MENU menu t function switch special function weighing temporary high resolution indication Indicators 0 zero indicator unloaded scale result stabilization indicator net weight after using T key MODE Special function menu turning on indicator B G gross weight after using TARE and gt key i AUT autotare function on tare memory function on TOTAL FILTER SUM special functions indicators ct n g m2 Ib mg unit indicators pcs pieces counting indicator n measurements quantity indicator total function OFF scale turned off standby I MIN weighing result under threshold thr function OK weighing result between threshold and Il I MAX weighing result above threshold BAT battery discharge indicator A 0 ACIIV function indicator bar indicator scale load indicator 0 100 During inscribing numerical values needed during using special functions keys have spe
14. BA30KX BAG0KX BA150KX BA300KX Maximal load Max Max 6 15kg 15 30kg 30 60kg 60 150kg Readout unit 91 92 2 59 5 109 10 209 20 5091 50 1009 Verification unit e1 e2 2 5g 5 10g 10 20g 20 50g 50 1000 Minimal load Min 100g 200g 400g 1kg Ill 15kg 30kg 60kg 150kg 300kg Minimal load Min Accuracy class Mo 3kg 6kg BA15NX HX 6 15kg 2159 0 2 0 5g 259 509 ig TH EC verification Scale type NES BA150NX BA300NX BA30HX BA60HX 150 BA300HX Maximal load Minimal load Min 100g 200g 400g Accuracy class 30kg 60kg 50kg 300kg 76 USER MANUAL Mcwaydms __ j 7 USER MANUAL 77 Notes 78 USER MANUAL
15. by in the following In order to go back to total weighing without zeroing total register press key several times USER MANUAL 59 To leave the function with clearing total register select fotAL function from menu and choose tot oFF option Scale prints the communicate informing about clearing registers The form of receipt after each measurement Date T Time measurementno weight measurementno weight Report form Date Time TOTAL WEIGHT NUMBER OF SAMPLES AVERAGE VALUE Note When the scale doesn t have an internal clock Date and Time do not appear on printout Maximum number of measurements is 99 999 Maximum total load 99 999 000d The weighing unit of the total value from the register Total is the same as the weighing unit stated on the keypad or is 1000 times greater what is signalled by o indicator at the left of the display If the registered value is too big to be displayed E communicate appears on the display If the number of series is too high and cannot be displayed Err1 communicate appears on the display 60 USER MANUAL 18 10 Checkweighing function thr This function allows comparing weighing result with two programmed reference values lower and upper threshold Comparison result is signalled with indicators MIN OK MAX and sound signal generated when threshold values are exceeded If comparison result is smaller than zero threshold no s
16. electronic equipment in waste containers e Please return wasted scale to the point of purchase or other company specialised in recycling of wasted electronic components USER MANUAL 13 6 Scale external outputs ME 01 meter in aluminium housing RxD receive Extensometer Feeder TxD transmission mass o O 12V 1 2A WY option P1 threshold 1 P2 threshold 2 P3 threshold housing ground 14 USER MANUAL ME 01 meter in stainless steel housing RS232C fo o9o housing 19 29 39 40 59 Feeder ground TxD transmission Separate ground connection scales in stainless steel version must be connected using additional conductor Extensometers are connected permanently USER MANUAL 15 6 1 Connecting a computer printer or label printer The scale is equipped with RS232C which can be used to connect external devices such as computer or a printer When cooperating with computer the scale sends weighing result after initialize signal from computer or after pressing gt key on the scale When cooperating with a printer data is send automatically after result stabilisation but next transmission is possible after removing previously weighted sample When cooperating with label printer after pressing Li key the scale sends instructions set for the label printer Label number 0001 hour data if t
17. m2 Press T lt key when n and PAP ArE is displayed Enter number of samples using 0 lt increasing digit T next digit MENU end of inscribing Press T key when PAP ArE is displayed Enter area of a single sample as above The result of paperweight measurement is finished with o mark pointing g m unit In order to finish work with function press MENU and then using T key choose PAPEr and PAP oFF Note PAP Err communicate marks that wrong values were inscribed in PAP n or PAP ArE USER MANUAL 71 19 Maintenance and repairs of small defects 1 The scale should be kept clean The balance must be kept clean and protected from dust and aggressive liquids In order to clean it is recommended to wipe the scale with cloth soaked in soapy water and then dry 2 Take care that no dirt gets between the platform and the scale base If found any remove the pan lift it up remove dirt and then replace the pan 3 In case of improper operation caused by short lasting power supply decay unplug the scale from the mains and then plug it again after few seconds 4 f the scale is switched on with empty pan and SErvic e communicate appears the load cell has been mechanically damaged 5 Itis forbidden to make any repairs by unauthorised persons 6 To repair the scale please contact our nearest service Error communicates Communicate Possible c
18. o S ST E s 150kg 200kg 300kg Wein time fee 230V 50Hz 8VA Internal supply option NIMH AA size 4 pcs Working time with about 6 h with display backlighting about 16h without backlighting accumulator Platforms A5 A6 A8 A Platform dimensions 400x400x120 400x500x100mm 600x500x135mm 800x800x150mm Base with column 400x660mm 600x660mm 800x960mm dimensions Scale with column height Scale weight 12kg 17kg 24kg 27kg increased readability for non EC verification applications Max d and e for double range scales are situated in appendix A 12 USER MANUAL 5 Security rules To avoid electrical shock or damage of the scale or connected peripheral devices it is necessary to follow the security rules below e To supply scale use socket with safety contact scales with feeder exluded e All repairs and necessary regulations can be made by authorised personnel only e avoid fire risk use a feeder of an appropriate type supplied with the scale Pay attention that supply voltage is compatible with specified technical data e Donot use the scale when its cover is opened e Do not use the scale in explosive conditions e Do not use the scale in high humidity e If the scale seems not to operate properly unplug it from the mains and do not use until checked by authorised service According to legal regulations it if forbidden to dispose wasted
19. stop bit no parity baud rate 9600bps After using gt key in scale Scale Label printer set of instruction in EPL 2 language that initialize label printing US Steering instruction FR 0001 Label number define instruction Instruction that starts list of variable signs mm gg 5 signs minutes hour rrrr mm dd 10 signs year month day masa 10 signs scale indication mass unit P1 Steering instruction Attention 1 Except variable signs constant signs can also be inscribed e g factory name product name and so on 2 In standard only one label pattern is possible to printout number 0001 Using bigger amount of patterns other label numbers is possible thanks to LAbEL special function 3 To achieve label printout label printer must have inscribed label pattern label pattern is created on computer and using computer it is saved to label printer memory Label pattern is designed by ZEBRA DESIGNER program which is supplied together with label printer 4 Scales parameters and transmission protocol must corespond to label printer type USER MANUAL 19 7 Preparation of workplace The workplace should be carefully chosen in order to keep to minimum influence of external factors that can disturb balance work Proper temperature and work space is crucial Balance should stand on stable foundation made o
20. sum of all samples sum x gt x x average value sum x n min minimal value from n samples max maximal value from n samples max min maximal value minus minima value S standard deviation s mno Y x x S srel variance factor srel X Statistical calculations results can be printed 68 USER MANUAL Order of operations if MAXIS A BISE IBIEISIE MODE ERE 90 mud MODE P Fr SER MODE aFF es MODE SER SEA CLA n pn MODE kL SER SER ER SEA CFG E fkg 4 90 id 100 Press MENU key When StAt is displayed press T lt key The following options are displayed StA monitoring and printout of statistical data SIA oFF deactivate function StA 7 activate function work with printout of chosen weighting results StA activate function work without printout StA n maximal samples value Sta nM inscribing nominal value for statistics Sta tOL inscribing tolerance in 96 Sta tAr automatic tare on off StA function configuration Auto Automatic work samples are confirmed after loading the scale and indication stabilization ManuAL manual work confirmation is made by pressing L key out exit from function Remember first to inscribe nominal weight value and tolerance
21. 0 key then charging time is about 10 hours 24 USER MANUAL 12 Scale with ME 01 meter keys and indicators LCD display version Keys Indicators bar zero stabilization net weight weighing metrological MAXIS OFF BAT CAL MIN OK MAX HARRAH K TOTAL FILTER SUM ct n g m2 Ib mg indicator we NET MODE B G AUT T pcs n OFF MIN OK MAX BAT A O indicator indicator indicator result data bar indicator AUT TOTAL 0 gt 04 mu NET BG T F aii M VO scale keys switch on switch off standby tare menu position confirmation next digit when inscribing zeroing scrolling menu increasing digit when inscribing result printout decimal point when inscribing menu function switch special function weighing temporary high resolution indication zero indicator unloaded scale result stabilization indicator net weight after using gt T lt key special function menu turning on indicator gross weight after using TARE and gt key autotare function on tare memory function on special functions indicators unit indicators pieces counting indicator measurements quantity indicator total function scale turned off standby weighing result under threshold thr function weighing result between threshold and Il weighing result above threshold Il battery discharge indicator ACtIV function indicator scale load indicator 0
22. 1 Declaration of Conformity iid di added ft d d t d t idus 72 sss tia rt to bo et re e dete td re o e to e Re n ete Ve d ora Ho a cd a 74 USER MANUAL 3 1 General description This manual describes scales produces by AXIS Sp z o o and their basic functions Standard execution scales are equipped with ME 01 A LED meter and stainless steel scales with ME 01 N LED In case of using these meters or special meter for eg batching meter it is essential to use proper user manual for individual meter type BA and BA M scales are designed for general use BA N series are destined for work in industrial conditions on water and detergents requiring immunity BAH series are destined for work in industrial conditions on salts and acids requiring immunity BA Y scales are designed for more precise measurements Double range option is described In Appendix A All scales are metrologically tested calibration or legal verification on demand Scales have following verification features aseal protecting scale casing against opening notified body stamps and green metrological marking placed on the balance name plate Legal verification is valid for 3 years unless the seal is broken To make a second legalization please contact with authorized service AXIS NACE classification 29 24 23 Depending on scale s application e g dosing labeling or computer cooperation scale can be equipped with following meter M
23. 20 04 kg 2012 11 08 10 01 20 04 kg 2012 11 08 10 01 Sample printout during normal weighing some printout positions activated BA30 MAX 30kg e d 0 01kg SN ID OPER 000001 DATE 2012 11 08 12 26 3 01 OPCS 0 000 g 3 08 kg 0 00 kg 3 08 kg 0 00 kg 42 USER MANUAL 17 6 Setting backlight function b_LIGHt AXIS 20 ied coreene 2 h L CHE bok aFF mn MODE b L bfit The function is used for choosing the work mode of scale display backlight b LOFF switch backlight off b Lon switch backlight permanently on b L ECO switch off after 30 seconds of inactivity no load changes and no key operation b LbAt like above but when powering from accumulators only out out without changes Switching backlight off causes decrease of energy consumption by the scale what is important during powering from accumulators USER MANUAL 43 17 7 Analog out configuration AnALoG AXIS This option enables to set up analog out 4 20mA or 0 10V working method used e g in PLC ma regulators Li Li kg inscribing Max value AnG CFG working mode configuration PLUS Ay x amp foe 09 workmode for only positive values MinuS only for negative values both for both 9 Rada Sh coh
24. 85 or LAN network with possibility to connect scanner and label printer options 2 displays digit weight indication and text menu and data stainless steel housing SE 22 N 2xLCD meter surcharge one ingredient or multi ingredient batching 2 displays digit mass indication and text recipe ingredients names etc stainless steel housing 2 Certificates Mi 9001 2009 Certificate of type approval AXIS management System Certificate no T7950 PN EN ISO 9001 2009 No AC 090 1141 2245 2011 3 Completeness Standard set consist of 1 Scale 2 Feeder In BA N and BA H scales only in accumulator versions 3 Guarantee card 4 User manual 6 USER MANUAL 4 Technical data Method for determining scale s type BA xx N K Y A0 H X A1 BA scale series name XX Scale s range Max no letter aluminium N stainless steel H hermetic K platform meter cable connection no lettter column Y precise 6000e X double range other 0 10 platform size BA popular platform scales meter on column version and BA K cable version Scale type BA3M BA6M BA15M BA15 Junt ns mu sec nsi na naa Dunn 2 l Platform A0 A A M M 0 059 0 1g 0 1g 0 1g 19 0 19 19 19 19 300g 600g 15009 3000g 60009 30009 60009 15kg 15kg Accuracy elass M Working 10 40 meee 3s 3m only K version
25. DE aunLE eR ln The function allows selecting weighing unit CarAt 1 ct 0 2 g carat MGrAM 1mg 0 001g milligram KGrAM 1kg 1000g kilogram Pound 1 lb 453 592374g English pound QOunCE 102 28 3495239 ounce QunCEt 10zt 31 1034763g pharmaceutical ounce GrAln 1gr 0 06479891g grain PennYW 1dwt 1 55517384g jewellery mass unit GrAM 19 gram The way of choosing carats as weighing unit is shown on the example Attention In scale with LED display designations of mass units Ib kg OZ Ozt ct are not displayed Units are pointed by diode light PEnntbU L RI MODE 9 USER MANUAL 39 17 4 Serial port parameters setting SErIAL The function allows setting independently EET communication parameters of both of serial ports LIL kg Port 1 and Port 2 executed in RS232C 5485 transfer protocol Prot LonG cooperation with printer or computer USB or LAN standard EPL cooperation with label printer in normal mode MODE activates LAbEL function x EPL_A cooperation with label printer in automatic al E J P mode activates LAbEL function EPL d cooperation with special label printers p Pen 01 cooperation with PEN 01 E I baud rate bAud 4800 9600 115 200bps number of bits in single char bitS 7 8 parity control PArItY MODE Pork 2
26. E 01 A LCD Standard universal ME 01 meter in aluminium A housing and with LCD display 18mm digits height Full set of special functions chapter 18 and standard set of keys ME 01 A 18 LED Standard universal ME 01 meter in aluminium A housing and with LED display 18mm digits height Full set of special functions chapter 18 and standard set of keys USER MANUAL ME 01 N 18 LED Standard universal ME 01 meter in stainless steel housing and with LED display 18mm digits height Full set of special functions chapter 18 and standard set of keys ME 01 N LCD Standard universal ME 01 meter in stainless steel housing and with LCD display 18mm digits height Full set of special functions chapter 18 and standard set of keys ME 01 N 25 LED Universal meter with LED display 25mm digits height in stainless steel housing Full set of special functions chapter 18 and standard set of keys ME 11 N LCD surcharge meter with numerical keyboard designed to operate special functions that need inscribing data e g product code unitary mass stainless steel housing ME 02 N LCD surcharge designed for one ingredient or multi ingredient batching numerical keys stainless steel housing USER MANUAL 5 SE 03 N LCD surcharge designed to cooperate with label printer numerical keys stainless steel housing SE 12 N 2xLCD surcharge designed to operate with computer through RS4
27. OLD 30 mod l fkg 00 Important notes Wait until the weighing result is averaged scale display blinks Then scale will show stable averaged result and will send it through serial port The result remains on display for about 30 second 1 The loads lower than Min value are not averaged 2 In case when putting animal on scale takes more than 5s it is suggested to choose LOC PRN option measurement started manually by pressing L gt key 54 USER MANUAL 18 6 Constant tare memory function tArE This function enables to measure gross weight of a sample placed in a container of a known weight value stored in the memory and to display calculated net weight of the sample Tare value is recalled from the memory with 0 or T key when the pan is empty Tare value may be entered using keypad or by putting container on the pan Inscribing tare value to memory 206 44 wz m BISI IBISESIS Ln E MODE Lie aff CE amp Re on Vi Vi re MODE SEL EAE 01 MODE ER E 02 PARAL PAn Diko STE re After pressing MENU key and choosing tArE function using T key the following options are available tAr OFF leave the function on activate the function with the previous tare value IAr sample tare value from the pan
28. Start Up ua e e e e ode ede e Pat e ean pe e 26 Weighing withitare us us soar mau e et e a e i eee ad e e t e o b a e i bet rd 27 15 Scale meni s oe e Lee Q Eu ae md o e qb Ed ade 28 16 Menu hayati meu 5 c ee ea d e e eee e eere edd e ab etr 29 IT Scale setup SEIUP oi c te t tu equ Q e b e dr 34 15 1 Scale calibration i ee e e dee eq e i eO b ee eq e e ade ata 36 17 2 Autozeroing function AUtOZET o oto oU ese Eo D f ant 37 14 3 Weight unitselection u eet c Up et itta e qe ga eo qi aa cepa ctos 38 17 4 Serial port parameters setting SErIAL R te dta t hs 39 14 5 Printout configuration Print eie got et epo eoe gota ege ato Bao qu aged had ds 40 11 6 Setting backlight function ttt ett gotten ge goo a tee t qo e 42 17 7 Analog out configuration AnALOG co c i pe ot tti in t qe aa oce ind fy de ota tp cie dede 43 17 8 Entenng reference zero value ZE OL u i o tco t and e t eo t t de o e a Gd o qM tede e t up den 44 18 Special functions description e re ete ee init Dre ce c i unas manna a 45 18 1 Products and users database Prod i USEr sesenta nina 46 18 2 Pieces counting function PCS essentia nitrate ti ti inea ti anta i iata i aha dieta ionis 50 18 3 Percentage weighing function PErC sse tnter tnnt tnter
29. a and scale operator id That information is inscribed using scale keys or scanner The function allows to switch on off following positions on the printout HEAdEr header name model and scale number USEr Id scale user identification number USEr nA user name no successive printout number choose this option to zero counter Prod Id product number Prod product barcode inscribed or scanned Prod nA product name Count counting result PCS function APW unitary mass PCS function netto net mass tArE current tare value GroSS gross mass totAL total mass fotAL function Attention If Prod Id or USEr Id is chosen it is possible to inscribe quickly their new values with omission of main menu In order to do that hold about 3 seconds MENU key and release it when Prod ld or USEr Id indicates Inscribe new value using keys increasing digit gt decimal point T next digit MENU end While inscribing Prod id user can use barcode reader connected to RS232C interface If the scale is equipped with two serial joints Print function is set independently for both interfaces USER MANUAL 41 Sample printout during normal weighing all printout positions deactivated 20 07 kg 20 04 kg 20 04 kg Sample printout during normal weighing with clock option all printout positions deactivated 20 07 kg 2012 11 08 10 01
30. ack to mass indication pressing MENU key out leave without changes An attempt of charging ordinary batteries can cause serious damage of the scale 66 USER MANUAL 18 14 Automatic switching off the scale function AutoOFF MAXIS 320 mdi 4 oe e lt cz bre MODE Hukaa t MODE AF FF MODE Cu re MODE AF bA 5min The function is helpful in scales supplied from accumulators The function causes scale to switch off automatically Press MENU key When AutoOFF is displayed press T key The following options appear successively on display AOF oFF deactivate function AOF on activate function scale turns off after 5 minutes of not making any actions AOF bAt as above but only when supplied from accumulators Out out without changes USER MANUAL 67 18 15 Statistical calculations function StAt This function evaluates from series of measurements max 1000 statistical parameters of weighting process Adding successively measurements to register is automatic and it occur after the scale is loaded and its indications stabilize After each loading printout is made with number of measurements result date and time if clock is installed and the function is activated For the obtained measurements series the scale evaluates n number of samples sum x
31. adability for non EC verification applications Platforms A A A Platform dimensions 250x260 400x400 400x500 x110mm x120mm x120mm Base with column dimensions 250x400mm 400x560mm 400x670mm Scale with column height 690mm Scale weight 12kg Attention BA6NY and BA6NKY with 0 1g readout unit and BA60NY and BA60NKY with 1g readout unit are only available in LCD display version 10 USER MANUAL BA N stainless steel platform scales and hermetic BA H meter on column version BA NK and BA HK cable versions Scale type BA15N BA15NK BA15H BA15HK Platform Ooo B O 0 1g 0 1g 1g 1g Verification unit e Minimal load Min Accuracy elass NIMH AA size 4 pcs only LCD version EC verification Y Working time with accumulator about 6 h with display backlighting about 16h without backlighting a Platforms Platform dimensions 250x260 x110mm Base with column dimensions 250x400mm Scale with column height Scale weight 3 5kg increased readability for non EC verification applications Max d and e for double range scales are situated in appendix A USER MANUAL 11 Hermetic and stainless steel platform cont Scale type BA300H BA300HK Platform 5 5 8 A10 Maximal load Max 15kg 30kg 60kg 150kg 200kg 300kg Readout unit d 100g 200g 400g Verification unit e 100g 10g 10g 10g g Minimal load Min 100g pou Tare range DEM temperature 10 40 gg
32. ale is not used but it is necessary to be ready to work immediately it can be switched off by pressing 1 key The scale reading system is then switched off to standby mode signalled by the indicator OFF in version with the LCD display To switch the scale on press I O key The scale is immediately ready to operate maximum accuracy after self tests Weighed sample should be placed in the centre of the pan N Place the scale on a platform to avoid dropping weighed objects on the pan Do not overload the scale more than 20 of maximum load 6 Protect the scale against dust aggressive dusts and liquids To clean the scale wash it with water with soap and dry it afterwards 7 A scale equipped with accumulators option automatically charges during normal work with feeder and controls accumulator state Charging control is executed by bAtterY special function The function enables to readout charging state and also to turn off charging in case of using normal batteries instead of accumulators Meter signalizes an accumulators discharge on LCD display and after around 1h the scale switches itself off to avoid discharging the accumulator below threshold voltage N Do not allow to fully discharge the accumulator as this could damage it After discharge signalising appears an accumulator should be charged as quickly as possible by connecting external feeder Charging is more effective when scale is turned off with 1
33. allows displaying weighing result in percents A measurement is performed in two phases first phase weighing a reference sample 100 second phase measuring specific sample as a percentage of the reference sample Weighing result is displayed in different format depending on the weight value of reference sample The function has the following options PEr oFF disable the function PEr on set current scale indication as 10096 and activate percentage weighing out exit without changing settings 1 PEr Err message informs that reference 100 mass is less than 0 5 Min or was not defined 2 In scales with LCD display sign is replaced with 52 USER MANUAL 18 4 Label choosing function LAbEL This function is used in scale with EPL SErIAL function data protocol This protocol enables label printout with actual scale indication and chosen data from Print special function variable data for example date and time Other data for example company address product name barcode can appear on label as a constant text Label patterns with number 4 digit used by user should be saved in scale memory according to printer manual Label pattern choice is made by inscribing label number using LAbEL function Press MENU button opibus When LADEL is displayed press T key H l4 E Actual label number will show E To enter new label number press T lt key MODE to exit function withou
34. arest service to calibrate the scale of mass should be used with Max value taken from scale technical data table In case of legalized scales with inaccessible calibration secure seal contact with service is Adjusting calibration scale should be made if the scale precision is not sufficient A standard recommended 22 USER MANUAL 10 Accumulator change in aluminium meters 1 Remove screws 11 holding plate 12 remove the plate Take out container with accumulators 13 and place 4 AA format accumulators The way of packing accumulators into the container is shown on the figure on the left and is also shown on the container Extensometer RS232C WY 12V 1 2A USER MANUAL 23 11 General rules of using scale 1 Before each measurement make sure that zero indicator is displayed If zero indicator does not display or communicate appears press 0 lt key and wait until zero indication and zero indicator appears 2 The scale is equipped with a tare equal to its range To tare the scale press T lt key left or right Storing a tare value does not extend measuring range but only subtracts it from a load placed on a pan To make weight control easier and to avoid range overdrawing the scale with LCD is equipped with a load indicator graduated in percentages Weighing result should be read when the indicator Z lights which signalises result stabilization 4 When the sc
35. ause Remedy C 1 6 ee if displayed more than 1 minute over 1 min contact an authorised service unLOAd the scale was switched on with loaded pan remove a load from the pan SErvic mechanical damage of the load cell contact an authorised service L pan missing put the pan on mechanical damage contact an authorised service H overloading remove the load from the pan mechanical damage contact an authorised service place the scale on a stable unstable ground a vibrations ground not affected by mechanical vibrations and indicator does not air flows airflows appear scale is damaged contact an authorised service taring in progress as above TER taring could not be finished the load is too small zero the scale or press B G key or B G key was used again the load is too big to be zeroed tare the scale gt T lt 12 USER MANUAL Declaration of Conformity AXIS Sp ka z 0 0 80 125 Gda sk ul Kartuska 375B confirm with all responsibility that scales BA3M BA6M BA15M BA15 BAO 3K BAO 6K BA1 5K BA3K BASMK BA6K BA6MK BA15K i BA15MK BA30 BA30K BA60 BA60K BA150 BA150K BA300 i BA300K BA30E BA60E BA150E BA1 5N BA3N BA6N BA15N BA30N BA60N BA150N BA300N BA1 5NK BA3NK BA6NK BA15NK BA3ONK BA6ONK BA150NK BA300NK BA1 5H BA3H BA6H BA15H BA30H BA60H BA150H BA300H BA1 5HK BA6HK BA15HK BA30HK BA60HK BA150HK BA300HK
36. carried out by Research Laboratory of Electrotechnology Institute Division Gdansk accredited by PCA Conformity T7950R0 evaluation was carried out by NMI Certin B V Notified Body No 0122 Per pro Director of AXIS Sp z o o Production Manager Jan Ko czak Date 14 11 2014 74 USER MANUAL Appendix A Information s concerning double range scale options 1 General description Double range scale s have capability of work with greatest accuracy in bottom measuring range part Weighing of smallest mass is more precise This type of scale s have two measurement range Maxi 50 of maximum load mostly Max 100 of maximum load and adequate reads digit d i d2 d1 lt d Double range options causes change of scale s operation after turn on in small mass range 0 Maxi scale displays result with reading unit d4 when the load pass the Max scale changes reading unit on d from this moment scale displays result with reading unit d2 on all measure range 0 return to unit di is succeed after zeroing the scale 0 lt key or then all mass is removed from pan indicator 0 Max Max USER MANUAL 75 2 Parameters of double range scales Scale type BA15X Maximal load Max Maxz 6 15kg Readout unit d1 d2 2 5g ification unit e ez 2 5g Minimal load Min 50g Il are range 15kg EC verification 7 Scale type BA15X BA30X BAGOX BA150X BA300X 15
37. cial functions 26 USER MANUAL 13 Start up Leave the pan empty plug a scale to the mains with wem a ground contact The scale proceeds with following uw start up actions MN OK Max MODE AUT TOTAL E Display test ctnozt HHBDmada ka gt C z o E EEUU kg aE ree PUE D Meter type displaying aa Program version adi kg The scale is now ready to work Attention Displaying program version means positive result of all tests USER MANUAL 27 14 Weighing with tare 9 9 0 0 T 017 2 fed 7 f 03 D EEUU d If the scale is not loaded and 0 lt indicator doesn t indicate press gt 0 lt key Zero indication and 0 lt indicator mean that the scale is ready to work After putting container package tare the scale using T key NET indicator will show up Put on weighted object and readout net weight NET indicator shows that scale indicates net weight In order to readout gross weight press t key B G indicator shows that scale indicates gross weight Press again key in order to come back to net indications 28 USER MANUAL 15 Scale menu All scales except for basic metrological functions weighing and taring have many special functions and configuration options MAXIS 30 mud Ac
38. com iS SEE UP MODE PIER MODE MODE MODE In order to ease using functions user can create his own personalized menu Creating personalized menu In out of the box scale after pressing MENU key only SEtuP option contains all configuration options is available One of the configuration options is Menu that is used to create personalized menu To add a function to personalized menu press T key when the function is indicating Chosen function is indicated with o sign on the left side of display After adding all necessary functions press out in order to come back to weighing mode User now after pressing MEnu key has access to selected earlier functions and to SEtuP option dEFAULt option is used to set factory settings USER MANUAL 20 16 Menu navigation rules TA age Auk aFF MODE Hut MODE Choosing menu options First position of scale menu shows up after pressing Menu key The position is displayed for about 7 seconds and then the scale sequentially displays next menu positions Choosing menu position option is done by pressing T key when it is displayed on the screen After choosing position option usually several options show up on turning on selected option OFF turning off out out to menu Accelerated working with menu
39. data configuration transmission Port 1 port 1 HEAdEr header scale type Max d e serial nr User Id scale operator id number User nA user name Prn no Succesive printout measurement number Prod Id product identification number Prod bA product barcode number Prod nA product name Cont pieces quantity PCS function APW product unit weight nEtto net weight tArE package weight tare Gross gross weight totAL total weight totAL function nr LCD measurement number and value in one line printout out exit Port 2 port 2 as above out exit dAtE ustawianie daty godziny if the scale is equipped with clock b setting backlight if display is backlighted b LoFF backlight off b Lon backlight on b L ECO turn off after 30 s without activity b L bAt as above but only when supplied from accumulators out exit AnALoG analog out setting AnG range value inscribing AnG CFG configuration plus minus both out exit 34 USER MANUAL bAttEry AUto OFF ZEro dEFAULt out turn on off accumulator charging if the scale is equipped with accumulator automatic turning off saving accumulator power as above scale start zero inscribing factory zero restore default settings for all options options only for service exit USER MANUAL 23 17 Scale setup SEtUP MAXIS 20 md SEtUP contains all options used for setting sca
40. el number in products database Prod ld product identification number Prod product barcode Prod nA product name inscribed from PC or barcode reader APW product unitary weight optional PtArE product package weight optional thr LO lower threshold MIN value thr Hl upper threshold MAX value Saving inscribed product data is done by using SAVE option 48 USER MANUAL Users database is edited by similar function named USEr and consists of several options USEr ld user identification number USErnA user name inscribed from PC or scanner Pm sending users database to port Saving data is also done by SAVE option Recalling from database MODE Peed id F qar dl 90 ad z s Faund ES The fastest way to recall product from database is to readout his barcode number Prod bA by using barcode reader option It can be done in any moment After readout of proper barcode scale indicates one of communicates SCAn barcode from outside the base accepted Std mode not Found barcode from outside the base not accepted LIMIt mode Found product barcode found in database and data recalled Attention If the scale doesn t indicate any communicate check barcode reader connections port configuration and transmission protocol SErIAL func
41. ers Below a list of functions available in standard ME 01 type meters Products data base Prod Users data base USEr pieces counting function PCS change of mass unit Unit percentage weighing function PErC selecting label number function LADEL weighing large animals function LOC entering tare function tArE maximum value indication function UP force measuring function nEWton statistical calculations StAt paperweight calculation function PAPEr an functions that require additional equipment to be completely functional option with accumulator supply Setting accumulators charging bAttErY Automatic switching off scale function AutoOFF Options with the clock setting current date and time function dAtE total weight function fotAL options with the transoptors connectors WY LI checkweighing function thr option with radio connection function of choosing communication channel rF Chn LabEL function is available in scales with EPL or EPL A transmission protocol activates go to SetuP SErIAL In scales with LED display special functions don t have additional marks on display and names of some functions are shortened 46 USER MANUAL 18 1 Products and users database Prod i USEr Scale is equipped with products and users database with capacity up to 300 products and 10 users Database consists of Database can be built in Excel datashe
42. et form where each product has one row and each column have product data This way created database saved in csv extension with semicolons can be send to scale using Scale Database software and scale s serial interface Scale Database is available on our webpage M nr memory number where data is saved Prod 1 product identification number Prod product barcode Prod nA product name USEr Id user identification number USEr nA user name APW unitary weight used when pieces counting PtArE inscribing permament tare to the product thr Lo threshold value low thr Hi threshold value upper WWW axis pl en Database and possibility to cooperate with external devices printer label printer barcode reader and computer enables to built product identification and product archiving systems Product barcode readout during scale working initiates searching through database and in case of finding proper record recalls product data Found communicate Barcode reader enables also to insert numerical data conveniently standard ME 01 meter doesn t have numerical keys Using alphanumeric code for example 128 code it can be also used to insert names of products and users 5 USER MANUAL 47 Inscribing data to base W705 gt 06 md TAA es pal p Glee MODE Pr ad MODE Ed tk MODE SEE CUM MODE p gea Peed ld Pr
43. f non magnetic impact material Violent air movements vibrations dustiness violent temperature changes or air density bigger than 90 is not allowed Scale should work away from heat sources and devices that emit strong electromagnetic field or radiation 20 USER MANUAL 6 Preparation to work Version with aluminium meter Mounting holder to meter Take the scale out of the package removing protective foils Take a pan off and remove protective elements from below the pan Place the scale on a stable ground not affected by mechanical vibrations and airflows Level the scale with the rotating rear legs so that the air bubble in the water level at the back of the scale is in the middle Lock the legs with the nut Puton the pan In scales with cable connection install indicator grip to indicator and then the indicator to the wall or the table 3 mounting variants to wall console USER MANUAL 21 Version with stainless steel meter SS T T ZZ ZX Mounting holder to meter 3 mounting variants to wall or console 9 Balance checking and adjustment It is advised to check scale indication accuracy before and after series of measurement using any load with known weight To check the scale with legal verification use a calibration weight with valid calibration certificate In case permissible error is exceeded it is advised to contact the ne
44. h 0Dh 0Ah Scale Computer without response USER MANUAL 17 Setting threshold 1 value option Computer Scale S L D1 DN CR LF 53h 4Ch D1 DN 0Dh 0Ah D1 DN threshold value maximum 8 characters negative value digits dot decimal separator number of digits after dot should be the same as on scale display Scale Computer without response Example in order to set low threshold 1000g in scale B1 5 d 0 5g the following order should be sent L1000 0 CR LF 53h 4Ch 31h 30h 30h 30h 2Eh 30h ODh 0Ah in order to set low threshold 100kg in scale B150 d 509 the following order should be sent L100 00 CRLF 53h 4Ch 31h 30h 30h 2Eh 30h 30h ODh 0Ah Setting threshold 2 value option Computer Scale S H D1 DN CR LF 53h 48h D1 DN 0Dh 0Ah D1 DN threshold value maximum 8 characters Scale Computer without response Setting threshold 3 value option Komputer Waga S M D7 DN CR LF 53h 4Dh Df DN ODh 0Ah gdzie D1 DN threshold value maximum 8 characters Waga Komputer without response Connecting cable WK 1 scale computer 9 pin interface SCALE COMPUTER lo 26 34 49 54 7o Connection cable WD 1 connects scale with AXIS printer SCALE KAFKA PRINTER lo 20 34 fo 54 70 9o 0 Setting of internal switches of AXIS printer 18 USER MANUAL 6 3 Detailed EPL protocol description Transmission parameters 8 bits 1
45. he clock is installed and on and nett weight During transmission LabEL communicate is displayed The way of sending data and transmission parameters is set using SEr AL special function Set of send data is set using special function Print The following data can be send Header scale type Max d e serial number Operator identification number Successive printout number measurement Identification number or product bar code Number of pcs PCS function only Single detail mass PCS function only Nett weight Tare package mass Gross weight Total mass Total function only If the scale is equipped with two serial joints Print function is set independently for both interfaces Computer must have a special program for cooperation with data from a scale Dedicated programs are also offered by AXIS Except RS232C joint the scale can be equipped with USB or Wi Fi interface Needed controllers and instruction can be found on a CD supplied with Axis scales 16 USER MANUAL 6 2 Detailed LonG protocol description Communication parameters 8 bits 1 stop bit no parity baud rate 4800bps initialising signal data send order correspond to press gt key Computer Scale S CR LF 53h 49h 0Dh 0Ah Scale Computer scale response according to description below 16 bytes Byte 1 sign or space Byte 2 space Byte 3 4 digit or space Byte 5 9 digit decimal point or space By
46. ignal smaller than lower threshold the scale signals MIN yellow colour between threshold values the scale signals OK green colour with the short sound signal greater than upper threshold the scale signals MAX red colour long sound signal The checkweighing results can be use to control Optical indicator Indication mode batching devices Batching mode Standard scale is set for cooperation with optical indicator On outputs P1 P3 Relays socket short circuit states appear as result of comparison scale indication with threshold values On the chart below output states are shown during increasing load on the scale for both working modes Indication mode Batching mode z ro thr 1 treshold P2 thr thr I the Il P3 P3 thr zero treshold In Batching mode on P1 thr l and P2 thr II outputs short circuit impulses appears for time of 0 5s On zero output short circuit state appears when indication does not exceed threshold value signalling zero load USER MANUAL 61 Operation sequence 2 SISSE MODE Es 8 khe aff Ehe o amp Mus Glen the EFE SEk L MODE SEE H MIN OK MAX ma if Press MENU key and choose thr pressing T key The following options are displayed successively thr oFF deactivate the function thr on
47. imensions 400x560mm 400x660mm 600x660mm Scale with column height Scale weight 14kg 17kg 26kg 49kg increased readability for non EC verification applications for BA15 A5 scale the height is 590mm Max d and e for double range scales are situated in appendix A 8 USER MANUAL BA Y precise platform scales meter on column and BA KY cable version e Jemen nm n BA6KY BAGMY BA12KY BA12MY BA30KY BA60KY BA120KY Plafom A2 A3 A3 M A3 M A5 Accuracy class Mp L sc 10 40 C lt 3s 3m only K version Internal supply option NIMH AA size 4 pcs only LCD version Working time with accumulator EC verification about 6 h with display backlighting about 16h without backlighting Platforms A2 A A x70mm x110mm x70mm x120mm Scale with column height 400 415 730mm Scale weight 12kg USER MANUAL 9 BA NY precise stainless steel platform scales meter on column version and BA NKY cable version BA6NKY BA12NKY BA60NKY BA120NKY Platform AA ed Verification unit e _ MEO CER Accuracy class Working temperature 10 40 C Weighing time Cable lenght 3m only K version nternal supply option NIMH AA size 4 pcs only LCD version Working time with accumulator about 6 h with display backlighting about 16h without backlighting EC verification increased re
48. key and then when StAt and Sta oFF is displayed press T lt button Statistics function cooperation with computer and Printer Scale can be equipped with two serial ports marked as RS232C l computer and RS232C II printer After each data printout by printer identical set of data is sent to computer After sending by computer initialization signal 5 A CR LF 53h 49h 0Dh 0Ah the scale sends to computer statistic data enclosed in histogram 70 USER MANUAL 18 16 Paperweight calculation PAP gt 06 mdi MODE IE x PAP s FF MODE MODE x MODE PRP MODE Hr E MODE MODE PHP an Pes LC gt quam Lt a This function enables to calculate paperweight of 1m of paper basing on samples of known area For quick access the function is accessible directly by pressing MENU key The balance must be tared just before the measurement Place the specific sample quantity of the same area possible values 1 2 5 10 20 50 100 Press MENU key to access Function Menu To enter the function press gt T lt key when PAPEr is displayed Following options show on the display PAP oFF turn off the function PAP on turn on PAP n inscribing number of paper pieces on pan PAP ArE inscribing surface of single piece in
49. le work mode MEnu creating personalized user menu 00 a CALIb scale sensitivity calibration 2200009659 h a AutoZEro ing self maintaining zero indication unloaded scale Unit weight unit selection SERUP PE nu MODE SErIAL setting serial ports Print transmission printout data selection FILtEr anti disturbance filter b LIGHt backlight setting Ad420 analogue out configuration FIrMW are updating software only for service dEFAULt reset to factory settings sample of using in chapter 15 CAL th D O O D O D L SErVICE service menu only for service D SE IRL Pr dal O dE dEFRULE SEru ICE 36 USER MANUAL 17 1 Scale calibration CALIb 90 mul 4 e ee zz Lew MODE SEEUP MODE CAL th MODE PAL an MODE CAL SEP t RL on PIE LU LDRd PRESS Press MENU key Press T lt key when CALIb function appears The following options will be displayed CAL on calibration with external recommended standard of mass see technical data CAL StP calibration with external weight confirmation of succesive steps MENU key out leave without changes Press T key when CAL S
50. ndication will show up 56 USER MANUAL 18 7 Maximum value indication function UP This function allows holding maximum or minimum value that is indicating at the moment Before measurement scale should be tared 30 mud Function has following options nn kg 1 UP oFF function off HIGH holding maximum value Pressing 7T key will cause result zeroing LOW holding minimum value n LIP MODE Note Autozeroing function the stabilisation indicator are deactivated when UP function is UP a FF running MODE UP HIGH MODE 10kg LP aly MODE e g DANAA USER MANUAL 57 18 8 Force measuring function nEWton Function activation causes displaying result in force units N Press MENU key kg Using T lt key choose NEWto function Function has several options nEW oFF function off Im nEW on measurement in Newtons ArM torque measurement arm length should be inscribed in meters using T 0 lt and nt L ul E mimi i MENU keys zT ET Attention ar Units convertion from mass kg to force is zi made for acceleration of gravity g 9 80665m s2 n nn Note 1N 0 1019kg 58 USER MANUAL 18 9 Total weight function totAL AXIS gt 06 mdi
51. od hA Prod nf Sea Vi Ct Ct rms khe LU Ehr H AL Prod and USEr options enables adding and deleting product and user data For products database available options are Edlt Add add product to database dEL OnE deleting single element from database dEL ALL deleting all elements from database dAtAb changing working mode with database default mode Stb e Stb searching products in database and working with products outside the base if product is found then Found communicate appears and all product data is recalled if there is no product in database then no communicate appears the scale stores id barcode number temporarily in memory and enables to send it to the port to printer computer together with actual weighing result e LIMIt searching through products from database if product is found then Found communicate appears and all product data is recalled if there is no product in database then not Found communicate appears Pm P sending all products database to port To inscribe data use Edlt option and keys 0 lt increasing digit T next dixit MENU end of inscribing Barcode reader connected to RS232C interface can also be used to inscribe data and this way it is faster and more effective Each database product has following data M Id memory c
52. sing SEtUP MEnu settings o Prod USEr PCS Unit PErc LOC tArE UP NEWton totAL thr StAt PAPEr out CAL on CAL StP out Aut on AUt OFF out CArAt ct MGrAM mg HGrAm kg Pound Ib ounCE oz ounCE ozt GrAin PEnnYW GrAM g out creating menu o added to menu choosing product choosing user pieces counting function actual unit selection percentage conversion function animals weighing function tare memory bank maximum value function force and torque value function summation series of measurements function threshold values comparing function statistics function paper grammage function exit sensitivity calibraton only not verificated scales fast calibration without confirmation of putting weight calibration with confirmation exit autozeroing autozeroing on autozeroing off lasts 10min exit unit choice carat miligram kilogram pound ounce aphotecary ounce grain jednostka jubilerska gram exit USER MANUAL 33 SErIAL serial ports settings settings Port 1 port 1 bAUd transmission speed 1200 115 200 bps bltS bits quantity 7 or 8 PArltY parity control SEndlnG transmission type Stab no StAb Auto Cont rEMoVE Prot protocol LonG EPL EPL_A EPL d PEn 01 SCAnn cooperation with barcode readers MJ 4209 Port 2 on port 2 as above out Print printout
53. t number change press MENU ko MODE To inscribe label number use keys 0 lt digit increase gt T next digit MENU end MODE 3 After entering label number putting load and pressing key will cause sending data to label printer 17 Data format sent to label printer label nr 1 E language EPL 2 US 55 53 0D 0A FR 0001 46522230 30303122 0D OA 0D 0A 00 00 30 30 30 30 0D 0A 2000 00 00 32303030 2 3030 2 303000 0A 10g 20202020 20313020 2067 0D 0A P1 50 31 0D 0 USER MANUAL 53 18 5 Weighing animals function LOC The function allows weighing animal moving on the scale TAXIS gt 06 di 00 1 P MODE LOC NUN MODE aFF LOC MODE LOC Pen MODE 30 mdi 00 7 3 S lt LOC 920 mid Sx P 2 9 1 Press MENU key When LOC function is displayed press T key The following options appear display successively LOC oFF leave the function LOC on automatic weighing after loading the scale LOC the measurement initiated manually by pressing Ey key When LOC on is displayed press T lt key Tare the scale using 7T key if necessary and tm place the animal on the pan Pe Ink H
54. tP option appears calibration in two steps Press T lt key when weight value used for calibration is indicating or use othEr option and inscribe proper value keys 0 Te Press MENU and wait for writing zero to the hy scale E When LOAD message appears put standard of mass on the pan Press MENU key CAL on doesn t need pressing MENU key Wait until internal calibration is finished and zero indication is displayed USER MANUAL 37 17 2 Autozeroing function AutoZEr m When the function is activated the scale nn automatically ensures stable zero indication if LR kg the pan is empty or if zero indication was acquired by pressing 7T lt key To turn on the function use MENU key and using T key choose AutoZEr and then Aut on E To leave the function press MENU key then E E l p ps with T key chose AutoZEr and Aut OFF Note 1 AUt sign occurs only in scales with LCD Hut cur mi T display 2 In scales with 0 key active function MODE MODE w changes name into AutoZE autozeroing and H Ap L n l works only when the scales is unbiased re Aot 38 USER MANUAL 17 3 Weight unit selection Unlt EZ LILI kg SEEUP ey MODE FR IRL w qg Rnn MODE HG APT ig Paund Eu MO
55. te 10 digit Byte 11 space Byte 12 k l p or space Byte 13 g b t cor Byte 14 space Byte 15 CR Byte 16 LF Attention Network number different than zero SErlAL nr function changes scale working mode communication with a computer is possible after logging the scale in with 02h scale number command To log the scale out use 03h command For example Using a program to test RS232 interface program is available in www axis pl programy komputerowe for scale number 1 please write 0201 to log in then S and write 03 to close communication Asking about scale presence in system testing scale connection with computer Computer Scale S J CR LF 53h 4Ah ODh 0Ah Scale Computer M J CR LF 4Dh 4Ah ODh 0Ah Displaying a inscription on scale s display text communicate from computer Computer Scale SNnnXXXXXX CRLF nn displaying time in seconds XXXXXX 6 signs to display Scale Computer M N CR LF 4Dh 4Eh 0Dh 0Ah Scale tarring calling T lt key press Computer gt Scale S T CR LF 53h 54h ODh 0Ah Scale Computer without response Scale zeroing calling 0 lt key press Computer Scale S Z CR LF 53h 5Ah 0Dh 0Ah Scale Computer without response Scale turning on off calling 1 key press Computer Scale S S CR LF 53h 53h 0Dh 0Ah Scale Computer without response Entering to special function menu calling MENU key press Computer Scale S F CR LF 53h 46
56. tetas 51 18 4 Label choosing function LAbEL essent tnnt tnnt tnt tante tatnen tetti 52 18 5 Weighing animals function LOG tnter tetti 53 18 6 Constant tare memory function l I n ann 54 18 7 Maximum value indication function UP 56 18 8 Force measuring function NEWION y u uu 57 18 9 Total weight T nction apun u e ERE ROO RO EUER ERROR DO EUER 58 18 10 Checkweighing function uuu eror er e er o COE e AERE LIRE tini 60 18 11 Setting date and time function dAE sesenta nna 63 18 12 Radio communication channel choice function rF CHn eene nnns 64 18 13 Charging accumulators function bAttErY option sse 65 18 14 Automatic switching off the scale function AutoOFF essent ttes 66 18 15 Statistical calculations function StAt seien tnter nente tentes 67 18 16 Paperweight calculation PAP ess sese tiet trente tret ti saa tena t tena di tena this 70 19 Maintenance and repairs of small defects sisse tete a 7
57. threshold value pay attention that its value is not below lower threshold value 3 Setting lower and upper threshold value is possible after sending appropriate orders from computer what is described in scale user manual USER MANUAL 63 18 11 Setting date and time function dAtE MAXIS 320 4 TA SIS BIS MODE aa bit x T dH dAk oFF dit on 8 dft P ln s an dA dA The function allows setting current date and time of scale internal clock and mode of its use The function has the following options dAt oFF deactivate date and time during printout of current weighing result dAt on activate date and time during printout of current indication IE key dAt SEt change current date and time dAt Pln data and time secure password to prevent from changing date and time by unauthorized personel dAt For data printout in USA or EU format The example at the left presents how to set current date and time using dAt SEt option After setting proper date and time activate it with dAt on option UE rrrr mm dd gg mm USA mm dd rrrr gg mm AM PM gg hours mm minutes AM before noon PM after noon mm month dd day rrrr year Attention Inscribing non zero PIN value causes showing PIN sign during next date and time changing and inscribing 4 digit code is necessary using keys gt 0 lt T and MENU
58. tion Other fast way is to press and hold MENU key Prod ld communicate indicates and after a few seconds user can inscribe identification number If the number is already saved in base Found communicate appears and all the product data is recalled To edit data choose Edit option and use following keys 0 lt increasing digit T next dixit MENU end of inscribing Product recalling is also possible by using Prod and Prod Id options previous site USER MANUAL 49 Weighing results and data transmission from scale to computer or to printer To each weighing results transmission a set of product and user identification data is added The set is activated in Print option 17 5 chapter Available data from products and users base Print SEtuP option USEr Id user identification number USEr nA user name inscribed from PC or scanner Prod ld product identification number Prod product barcode inscribed or scan Prod nA product name inscribed from PC or scan 50 USER MANUAL 18 2 Pieces counting function PCS Cy E gt 5 y WE 3 0 id MAX S 0 id Fig le MODE WE FI l r ot A an 20 id NET c pcs a 20 id NET 5 pcs al This function enables to count identical pieces e g turnbuckles or buttons