1. See CUTOUT DIMENSIONS for recommended receptacle location NANC e SERVIC Electrical 1 USER GUIDE U LINE u line com SAFETY gt INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINT Cutout Dimensions PREPARE SITE Your U Line product has been designed for either free standing or built in installation When built in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed and clearance is required for an electrical and water connection in the rear Units can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS Filler Panel Not Provided by U Line Needed to Attach Mounting Flange on Unit 3 4 19 mm Minimum Flange Mounting Area Preferred location for water line and 0 eletrical outlet is in 1871 2 470 adjacent cabinet Minimum Cutout 5 8 Height Fa 16 mm 25 1 16 178 mm 5 637 mm 4 102 mm Bo 3 4 gt ke 14 1 4 gt Le Sen Kick 19 mm 362 mm 19 mm Minimum Flange Cutout Width Minimum Flange Mounting Area Mounting Area NOTICE It is extremely important that this unit sits on a level surface as it does not have feet levelers If it is not level the ice mold will not fill evenly NANCE e SERVIC Cutout Dimensions 1 USER GUID
2. 2 Clean the condenser coil using a using a soft brush with a combing action or vacuum cleaner Do not touch the condenser coil 3 Install the grille Cleaning Condenser 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OP Extended Non Use VACATION HOLIDAY PROLONGED SHUTDOWN The following steps are recommended for periods of extended non use 1 Remove all consumable content from the unit 2 Disconnect the power cord from its outlet socket and leave it disconnected until the unit is returned to service 3 Turn off the water supply 4 If ice is on the evaporator allow ice to thaw naturally 5 Clean and dry the interior of the cabinet Ensure all water has been removed from the unit 6 Disconnect the water and drain line if applicable making sure all water is removed from the lines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or less the steps above must be followed In addition P60 drain pumps in clear ice m according to the followi 1 Remove the drain p Ng 2 Drain the water in t pump upside down and achines must be drained procedure ump from the ice machine allowing the water to drain through the pump s inlet and vent tube fittings 3 Af
3. hinge and carefully lift off the door latch assembly 13 Place the door latch assembly on opposite side of unit Be sure to tighten all three screws securely ERATING INSTRUCTIONS MAINTENANC 5 RVIC 14 Place door on lower hinge pin Invert and install upper hinge on door Fasten upper hinge to unit three screws Partially tighten screws 15 Adjust door to ensure proper seal Tighten upper and lower hinge screws securely 16 Replace screws in holes in bottom of unit on opposite side 17 Replace the grille Door Adjustments 3 USER GUIDE U LINE u line com SAFETY INSTALLATION 8 INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE Door Latch The door latch assembly included with your unit can be installed to prevent the door from opening when the vehicle is in motion To install perform the following 1 Remove the two outer most screws from the non hinge side 2 Place latch over mounting holes 3 Re install the screws but do not tighten all the way 4 Verify door latch engagement and adjust as necessary 5 Tighten screws Door Latch 1 USER GUIDE U LI NE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAIN First Use All U Line controls are preset at the factory Initial startup requires no adjustments NOTICE
4. potable water supply only DU O ERATING INSTRUCTIONS MAINTENANCE 6 Do not use any plastic water supply line The line is under pressure at all times Plastic may crack or rupture with age and cause damage to your home Do not use Teflon tape or joint compound on the water fitting The rubber washer provides an adequate seal Other materials could cause blockage of the valve Failure to follow recommendations and instructions may result in damage and or harm flooding or void the product warranty Use new hose set Do not reuse old hose set Turn off water supply and disconnect electrical supply to unit prior to installation Use caution when handling back panel The edges could be sharp 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Remove the grille access panel in the front and the back panel Water Hookup 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION 8 INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE e SERVIC 3 Locate water 6 Turn on water supply and check for leaks valve in the front of the unit and thread water o 09 9 9 supply line through 8 Install retaining clip 7 Reinstall back panel and grille front access panel 509 NOTICE Route the water supply line th
5. will need your product Model and Serial Numbers This information appears on the Model and Serial number plate located on the wall of the interior of your product NORMAL OPERATING SOUNDS upper right or rear All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite this technology your model may make sounds that are unfamiliar Normal operating sounds may be more noticeable because of the unit s environment Hard surfaces such as cabinets wood vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed e Compressor The compressor makes a hum or pulsing sound that may be heard when it operates ERATING INSTRUCTIONS MAINTENANCE SERVICE e Evaporator Refrigerant flowing through an evaporator may sound like boiling liquid e Condenser Fan Air moving through a condenser may be heard e Automatic Defrost Drain Pan Water may be heard dripping or running into the drain pan when the unit is in the defrost cycle TROUBLESHOOTING GUIDE A DANGER ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before disconnecting the main electric
6. E U LINE 9 u line com SAFETY e INSTALLATION 8 INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE gt Product Dimensions d 8 15 16 227 mm 17 432 25 1 16 637 mm 14 356 mm Add 1 1 2 For For Water Line Clearance Product Dimensions 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Water Hookup PREPARE PLUMBING The water valve in this unit uses a standard 1 4 6 35 mm compression fitting U Line recommends a braided stainless steel water supply line P N WATERHOOKUP Plumbing installation must observe all state and local codes All water and drain connections MUST BE made by a licensed qualified plumbing contractor Failure to follow recommendations and instructions may result in damage and or harm Water Supply Connection When connecting the water supply please note the following e Before installing the unit and connecting to the cold water supply review the local plumbing codes e The water pressure should be between 20 and 120 psi 138 and 827 kPa 4 he water line MUST have a shut off valve in the supply line he water line should be looped into 2 coils This will low the unit to be removed for cleaning and servicing ake certain that the tubing is not pinched or damaged uring installation Connect to
7. RUCTIONS MAINTENANCE e SERVIC Grille Plinth Installation REMOVING AND INSTALLING GRILLE Disconnect electric power to the unit before removing the grille DO NOT touch the condenser fins 4 The condenser fins are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the screw 1 3 Remove grille 2 from unit Installing the grille 1 Align cabinet and grille holes and secure but do not over tighten grille screw 1 2 Reconnect power to the unit Grille Plinth Installation 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE e SERVIC Door Swing All units have a zero clearance for the door to open 90 U Line recommends a minimum door clearance of 3 4 19 mm to accommodate the handle if the unit is installed next to a wall or similar type of structure Wals y 3 4 19 mm Door Swing 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Door Adjustments CHECKING DOOR ALIGNMENT The unit s door is aligned at the factory before shipment However its alignment could have been disturbed during shipment NOTICE Properly aligned the door s gasket sh
8. U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line To turn the unit on or off Press the rocker switch located inside the door on the front panel or behind the grille NANC 5 RVIC First Use 1 USER GUIDE U LINE u line com SAFETY gt INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE e SERVIC Ice ICE MAKER OPERATION When the ice bucket is full the ice making mechanism will shut off However the refrigeration system will continue to cool and maintain the ice supply NOTICE Do not place cans or bottles in the ice compartment because they will freeze To turn off ice production Raise the bin arm into an upright and locked position The unit will preserve temperature for ice storage NOTICE If not intending to use the ice maker turn the water supply valve off It is also important to raise the bin arm of the ice maker see above Failure to raise the bin arm may result in damage to the water valve Certain sounds are normal during the unit s operation You may hear the compressor or fan motor the water valve or ice dropping into the ice bucket NEVER use an ice pick knife or other sharp instrument to separate cubes Shake the ice bucket instead During periods of limited use or high ambient
9. USER GUIDE SAFETY e INSTALLATION amp INT ga L q ees sao PRODUCT R Marine Series gt BI95FC gt 14 Crescent Ice Maker EGRATION e OP ERATING INSTRUCTIONS e MAINT ti d SN NANC RVIC USER GUIDE O vu Line u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINTENANCE Contents Intro Troubleshooting Warranty Safety Safety and Warning Disposal Installation Environmental Requirements Electrical Cutout Dimensions Product Dimensions Water Hookup General Installation Integrated Panel Installation Grille Plinth Installation Door Swing Door Adjust Door Latch Operating Instructions First Use Ice Airflow and Product Loading Maintenance Cleaning Cleaning Condenser Extended Non Use Service Accessories USER GUIDE U LINE u line com WELCOME TO U LINE Congratulations on your U Line purchase Your product comes from a company with over five decades and three generations of premium modular ice making refrigeration and wine preservation experience U Line continues to be the American leader delivering versatility and flexibility for multiple applications including residential light commercial outdoor and marine use U Line s complete product collection includes modular Wine Captain Models Beverage Centers Clear Ice Machines Crescent Ice Mak
10. al power Troubleshooting What to check when problems occur Problem Possible Cause and Remedy Light Remains on When Door Is Closed Turn off light switch if equipped Check reed switch Unit Develops Frost on Internal Surfaces Frost on the rear wall is normal and will melt during each off cycle f there is excessive build up of 1 4 or more manually defrost the unit Ensure the door is closing and sealing properly High ambient temperature and excessive humidity can also produce frost Unit Develops Condensation The unit is exposed to excessive humidity oisture will dissipate as humidity levels on External decrease Surfaces Product Is Because product in contact with the rear wall Freezing may freeze ensure no product is touching the rear wall Adjust the temperature to a warmer set point Troubleshooting 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Causes which affect the internal temperatures of Problem Possible Cause and Remedy 3 the cabinet include Product is Not Air temperature does not indicate product Cold Enough temperature See CHECKING PRODUCT TEMPERATURE below Adjust the temperature to a cooler set point Ensure hee ve e Ambient temperature where installed ambient temperatures or in direct sunlight Ensure the d
11. ement clockwise for a COLDER setting slower ice production or counterclockwise for a WARMER setting faster ice production 12 2 Oo O Q e 9 Warmer Colder 1 Remove the ice maker assembly cover 1 3 Reinstall the front grille one screw 2 Find the adjusting screw on the ice maker assembly control box 2 The adjusting screw is just below the minus and plus signs on the control box Too large of an adjustment to the screw can cause the water to overflow the ice maker and can cause property damage Ice 2 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE gt SERVIC Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected Do not install the unit behind a door Airflow and Product Loading 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OP Cleaning EXTERIOR CLEANING Vinyl Clad Black or White Models Clean surfaces with a mild detergent and warm water solution Do not use solvent based or abrasive cleaners Use a soft sponge and rinse with clean water Wipe with a soft clean towel to prevent water spotting Clean any glass surfaces with a non chlorine glass cleaner Stainless Models Stainless door panel
12. ers Glass amp Solid Door Refrigerators Drawer Models Freezers and Combo Models U Line has captivated those with an appreciation for the finer things with exceptional functionality style inspired innovations and attention to even the smallest details We are known and respected for our unwavering dedication to product design quality and selection U Line is headquartered in Milwaukee Wisconsin with a west coast office located in Laguna Beach California and European support in Dublin Ireland U Line has shipped product to five continents for over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com under Documentation PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please take the following steps 1 U Line Customer Care must be contacted immediately at 1 800 779 2547 2 Service or repairs performed on the unit without prior written approval from U Line is not permitted If the unit has been altered or repaired in the field without prior written approval from U Line claims will not be eligible SERVICE INFORMATION Answers to Customer Frequently Asked Questions are available at u line com unde
13. grated panels use household cleaner per the cabinet manufacturer s recommendations INTERIOR CLEANING Disconnect power to the unit Clean the interior and all removed components using a mild nonabrasive detergent and warm water solution applied with a soft sponge or non abrasive cloth Rinse the interior using a soft sponge and clean water Do not use any solvent based or abrasive cleaners These types of cleaners may transfer taste to the interior products and damage or discolor the interior Cleaning 1 USER GUIDE U LINE u line com ERATING INSTRUCTIONS e MAINTENANCE SERVIC SAFETY INSTALLATION amp INTEGRATION OP DEFROSTING Manual Defrost Models This unit is a manual defrost model and will require occasional defrosting When there is build up of 1 4 6 mm or more of frost manually defrost the unit DO NOT use an ice pick or other sharp instrument to help speed up defrosting These instruments can puncture the inner lining or damage the cooling unit DO NOT use any type of heater to defrost Using a heater to speed up defrosting can cause personal injury and damage to the inner lining To defrost 1 Disconnect power to the unit 2 Remove ice bucket and discard ice 3 Place towel or other absorbent material on bottom of ice bin 4 Fill the ice bucket half full with warm not hot water This will help the unit defrost faster 5 Place the ice bucket back int
14. hat defective parts be returned at your expense to U Line s factory in Milwaukee Wisconsin for inspection Any action by you for breach of warranty must be commenced within one year after the applicable warranty period 8 THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE DISCLAIMED U Line s sole liability and your exclusive remedy under this warranty is set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or installation of the product or from any other cause whatsoever whether based on warranty express or implied or otherwise based on contract tort or any other theory of liability Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty 6 2014 Rev G NANC e SERVICE Warranty 2
15. he product should be promptly completed by you and mailed back to U Line or you can register on line at www u lineservice com The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase and only if U Line s Product Registration Card included with the ERATING INSTRUCTIONS MAINTENANCE SERVICE unit is completed and mailed back or electronically submitted to U Line This 30 day warranty does not apply to cosmetic damages A proof of purchase may be required The following conditions are excluded from this limited warranty use of cleaners other than the recommended stainless steel cleaners and U Line Clear Ice Maker cleaner installation charges damages caused by disasters or acts of God such as fire floods wind and lightning damages incurred or resulting from shipping improper installation unauthorized modification or misuse abuse of the product customer education calls food loss and spoilage door and water level adjustments except during the first 30 days from the date of installation defrosting the product adjusting the controls door reversal and cleaning the condenser U Line product are designed to operate in ambient temperatures between 50 F and 100 F unless otherwise noted in the product manual Exposure to temperatures outside this range may cause degradation of perfor
16. humidity drops Damages caused by ambient temperatures of 40 F 10 C or below are not covered by the warranty Environmental Requirements 1 USER GUIDE LINE u line com SAFETY gt INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINT Electrical SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or removing power cord removing power plug or direct wiring can cause serious injury fire loss of property and or life and will void the warranty Never use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended A GFCI ground fault circuit interrupter is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes
17. mance and issue such as lower ice production or spoiled contents are not covered under the terms of this warranty as a result of that exposure U Line product may not be subjected to temperatures below 40F without following the winterization and vacation shutdown procedures in the user guide U Line s Outdoor Limited Warranty set forth in this Paragraph 6 shall apply to U Line models deemed suitable for outdoor use by Underwriters Laboratory UL as noted in the U Line Product Catalog U Line s website and or on the serial tag located inside the product A Outdoor product may come into contact with rain by virtue of outdoor use Exposure to other sources of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spray from a hose or similar device into and around the unit Warranty 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINT 7 Ifa product defect is discovered during the applicable warranty period you must promptly notify either U Line at 8900 N 55th Street Milwaukee Wisconsin 53223 USA or at 1 800 779 2547 or the dealer from whom you purchased the product In no event shall such notification be received later than 30 days after the expiration of the applicable warranty period U Line may require t
18. moderate personal injury property or equipment damage Safety and Warning 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Disposal and Recycling DANGER RISK OF CHILD ENTRAPMENT Before you throw away your old refrigerator or freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appliances and follow these steps completely 1 Remove all consumable contents from the unit 2 Unplug the electrical cord from its socket 3 Remove the door s drawer s Disposal and Recycling 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE e SERVIC Environmental Requirements This unit is designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will evaporate when the
19. ng SCrews 7 Relocate plastic spacer bushing on top and bottom of door to opposite side Clean out bushing hole in door bottom with a screwdriver if necessary 8 Using a Phillips screwdriver remove the two screws holding the custom stainless handle from the original location and remove the handle Remove the two screws on the opposite side of the door Do not place handle on door until you have completed step 9 ERATING INSTRUCTIONS MAINTENANCE e SERVIC 9 Remove plastic hole plug from door handle and relocate to opposite side Lift the handle slightly and press on the locking tab then gently pry the hole plug out of the hole being careful not scratch the top cap Hinge Screw 1 0 0 Plastic Hole Plug 0 o 9 0 Plastic dy Hole Plug d CM Right Side an Left Side Door Swing Door Swing lt Right Side Invert Hinge Screw Invert Hinge 10 Attach handle removed in Step 8 to opposite side of door frame Be sure to tighten all four screws removed in Step 8 11 Remove pivot screw from top hinge invert screw and reinstall pivot screw in top hinge Press in locking tab then lightly pry up to remove hole plug and move to opposite side Door Adjustments 2 USER GUIDE U LINE u line com SAF ETY e INSTALLATION amp INTEGRATION OP 12 Remove all three screws on the opposite side of the
20. o the unit on top of the towel or other absorbent material 6 Prop the door in an open position 2 in 50 mm minimum 7 After about 1 hour remove the ice bin and discard water 8 Allow the frost to melt naturally 9 After the frost melts completely clean the interior and all removed components See INTERIOR CLEANING NOTICE DO NOT clean ice bucket using a dishwasher The bucket is not dishwasher safe and will be damaged 10 When the interior is dry reconnect power and turn unit on NOTE To safeguard against contaminates in ice discard first three batches of ice after defrosting Cleaning 2 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Cleaning Condenser Condenser INTERVAL EVERY SIX MONTHS e To maintain operational efficiency keep the front grille free of dust and lint and clean the condenser when necessary Depending on environmental conditions more or less frequent cleaning may be necessary Disconnect electric power to the unit before cleaning the condenser DO NOT touch the condenser fins The condenser fins are SHARP and can be easily damaged NOTICE DO NOT use any type of cleaner on the condenser unit 1 Remove the grille See GRILLE PLINTH INSTALLATION
21. oor is closing and sealing properly Ensure the too long Ensure nothing is blocking the front grille found at the bottom of the unit The number of door openings and the time the door is Ensure the condenser coil is clean and free of any dirt or lint build up Temperature setting nterior light has not remained on e Installation in direct sunlight or near a heat source open The time the internal light is illuminated This mainly CHECKING PRODUCT TEMPERATURE affects product on the top rack or shelf e Obstruction of front grille or condenser To check the actual product temperature in the unit 1 Partially fill a plastic nonbreakable bottle with water 2 Insert an accurate thermometer 3 Tighten the bottle cap securely 4 Place the bottle in the desired area for 24 hours 5 Avoid opening the unit during the testing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Troubleshooting 2 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OP Warranty U LINE CORPORATION LIMITED WARRANTY 1 U Line Corporation U Line warrants each U Line product to be free from defects in materials and workmanship for a period of one year two years on Modular 3000 Series from the date of purchase U Line further warrants the sealed sy
22. ould be firmly in contact with the cabinet all the way around the door no gaps 1 Carefully examine the door s gasket to ensure that it is firmly in contact with the cabinet 2 When inspecting door alignment make sure the door gasket is not pinched on the hinge side of the door ALIGNMENT AND ADJUSTMENT 1 Loosen do not remove top and bottom hinge screws 2 Align door squarely with cabinet Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 3 Tighten bottom hinge screws 4 Tighten top hinge screws REVERSING THE DOOR Location of the unit may make it desirable to mount the door on the opposite side of the cabinet The hinge hardware will be removed and reinstalled on the opposite side of the cabinet ERATING INSTRUCTIONS MAINTENANCE e SERVIC To reverse the door mounting perform the following 1 Remove grille see GRILLE PLINTH INSTALLATION 2 Remove top hinge from cabinet three screws Hold door to keep it from falling Hinge screws 3 Lift the door off the bottom hinge 4 Remove bottom hinge from cabinet two screws 5 Remove screws on opposite side of cabinet Door Adjustments 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP 6 Install hinge on opposite side at bottom of cabinet Align hinge outer edge with cabinet before tighteni
23. r Customer Care or you may contact our Customer Care group directly contact information below GENERAL INQUIRIES SERVICE amp PARTS ASSISTANCE U Line Corporation Monday Friday 8 00 am to 5 30 pm CST 8900 N 55th Street T 1 800 779 2547 ilwaukee Wisconsin 53223 USA F 1 414 354 5696 onday Friday 8 00 am to 4 30 pm CST Service Email onlineservice u line com T 1 414 354 0300 Parts Email onlineparts u line com F 1 414 354 7905 Email sales u line com u line com CONNECT WITH US f wW D Sr in V Pg blog Designed engineered and assembled in WI USA Introduction 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Safety and Warning NOTICE Please read all instructions before installing operating or servicing the appliance Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type DANGER Danger means that failure to follow this safety statement will result in severe personal injury or death Warning means that failure to follow this safety statement could result in serious personal injury or death Caution means that failure to follow this safety statement may result in minor or
24. rough the unit so it does not come into contact with any internal components other than the solenoid valve Normal operation creates some vibration A water supply line contacting an internal component or cabinet wall can cause excessive noise during operation or damage to the line 4 On the back panel break away filler feature in bushing with flat screwdriver Remove with flat screwdriver 5 Thread water line through back panel hole with bushing 6 9 Water Hookup 2 USER GUIDE U LINE u line com SAF Ge ETY INSTALLATION amp INTEGRATION OP neral Installation LEVELING INFORMATION NOTICE Because these units do not have leveling legs it is extremely important that they sit on a level surface If they are not level the ice mold will not fill evenly Use a level to confirm the unit is level Level should be placed along top edge and side edge as shown ERATING INSTRUCTIONS MAINT INSTALLATION 1 Plug in the power electrical cord NANC 5 RVIC 2 Gently push the unit into position Be careful not to entangle the cord and water line 3 Re check the leveling from front to back and side to side Make any necessary adjustments 4 Remove the interior packing material and wipe out the inside of the unit with a clean water dampened clo
25. s handles and frames can discolor when exposed to chlorine gas pool chemicals saltwater or cleaners with bleach Keep your stainless unit looking new by cleaning with a good quality all in one stainless steel cleaner and polish monthly For best results use Claire Stainless Steel Polish and Cleaner which can be purchased from U Line Corporation Part Number 173348 Comparable products are acceptable Frequent cleaning will remove surface contamination that could lead to rust Some installations may require cleaning weekly Do not clean with steel wool pads Do not use stainless steel cleaners or polishes on any glass surfaces Clean any glass surfaces with a non chlorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this includes glass tile and counter cleaners ERATING INSTRUCTIONS e MAINTENANCE SERVIC If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using abrasive pads such as ScotchBrite will cause the graining in the stainless to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean inte
26. stem consisting of the compressor condenser evaporator hot gas bypass valve dryer and connecting tube in each U Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase During the initial one year warranty period two years on Modular 3000 Series for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs performed by a U Line authorized service company incurred in connection with the replacement of any defective part During years two through five of the warranty period for the sealed system U Line shall 1 at U Line s option repair or replace any part of the sealed system and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs incurred in connection with the replacement of any defective part of the sealed system All other charges including transportation charges for replacements under this warranty and labor costs not specifically covered by this warranty shall be the responsibility of the purchaser This warranty extends only to the original purchaser of the U Line product The Product Registration Card included with t
27. temperatures it is common for cubes to fuse together Gently shake the bucket to break apart cubes If not using the ice maker regularly empty the ice bucket periodically to ensure fresh cubes It is normal for cubes to appear cloudy The cause is air trapped in the water because of fast freezing It is not caused by the health taste or chemical make up of the water It is the same air that is in every glass of water you drink Remove the ice bucket for emptying and cleaning To remove the ice bucket raise the bin arm and remove the bucket from the ice compartment Use the ice bucket for ice storage only Ice 1 USER GUIDE U LINE u line com SAFETY gt INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC ICE MAKER ADJUSTMENT 3 Turn the adjusting screw toward the minus sign clockwise for smaller cubes or toward the plus Ice Cube Thickness Adjustment sign counterclockwise for larger cubes Interval As Required On ice maker equipped models adjust the cube size by changing water amount injected into the ice maker assembly as follows 4 Install the ice maker assembly cover ADJUSTING ICE HARVEST 1 Remove the front grille see GRILLE PLINTH INSTALLATION s S 2 Using a flat tip screwdriver turn the adjusting screw 1 3 a small incr
28. ter water is drained reinstall the drain pump and reattach all connections ERATING INSTRUCTIONS e MAINTENANCE SERVIC For questions regarding winterization please call U Line at 1 800 779 2547 Damage caused by freezing temperatures is not covered by the warranty Do not put anti freeze in your unit he pump s reservoir by turning the Extended Non Use 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINTENANCE 5 SERVICE Accessories 80 51004 00 WATERHOOKUP Accessories Anti Tip Mounting Brackets US 18 99 Accessories Braided Water Line Supply Kit US 49 00 Accessories 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INT Troubleshooting BEFORE CALLING FOR SERVICE EGRATION OP If you think your U Line product is malfunctioning read the CONTROL OPERATION section to c the function of the control learly understand If the problem persists read the NORMAL OPERATING SOUNDS and TROUBLESHOOTING GUIDE sections below to help you quickly identify common problems and possible causes and remedies Most often this will resolve the problem without the need to call for service IF SERVICE IS REQUIRED If you do not understand a troubleshooting remedy or your product needs service contact U directly at 1 800 779 2547 Line Corporation When you call you
29. th General Installation 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Integrated Panel Installation This model accepts a 1 4 insert panel INSERT PANEL INSTALLATION Install the insert as follows Use care when handling the insert Insert edges may be sharp 1 Remove top hinge screw pin with Phillips head screwdriver Remove door by tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force ses 3 Remove top screw on each side securing door handle Slightly 5 separate door handle from door 9 4 Pull handle up and off 8 ERATING INSTRUC 5 Slide custom TIONS MAINTENANCE e SERVIC door panel insert into 1 4 6 mm channel in door front 6 Holding door door making gasket out of the way replace handle on sure it is seated properly on insert and that screw holes line up 7 Install two small screws removed in Step 3 8 Starting at th gasket into p e corners and working inward push door ace on door 9 Place door on screw bottom hinge pin and install upper hinge Integrated Panel Installation 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INST

Download Pdf Manuals

image

Related Search

Related Contents

FS1A Safety Control Series  SWITEL BF300  Renesas R5F1026AASP#V0 datasheet: pdf  Fitting instructions Make: Permanently linked to quality T ype: 3905  MIP Getting Started (englisch, PDF 789 KB) Version    ダ~ストノミックスは定期的にお手入れをする必要 ゞあり ます  User Manual - Syd-Com  

Copyright © All rights reserved.
Failed to retrieve file