Home
Fatek OPC Server
Contents
1. even if the OPC client connect with FatekNetOPC Server it cannot access the register data from PLC It is because the FatekNetOPC Server does not get the IP address information from FBs CBEH FATEK Automation Corporation bum X Spat New Open Save File FATEK Space el Data Conversions E Simulation Signals f Alarm Definitions temID FBsSOMC RO FBsSOMC R1 i E Folder ph ee evice Add Item Name Simulate Symbol Register Address Data Type 2 RO0 No R 0 UINT Ri Na R 1 TINT Fatek OPC Server User Manual gt be x Delete y Multiply Tools 4 we Name FBS6OMC Station No IP Setting Use Service Call Back Use Simulation Timestamp Quality 2015 6 30 FF 02 56 50 Bad 2015 6 30 FF 02 56 50 Bad Limit Not Limited Not Limited After executing active call back program the FatekNetOPC Server get the IP from FBs CBEH and make connection successfully a ee 1 Bam amp Export New Open Save File a FATEK Space ea Data Conversions H Simulation Signals i a 5 Alarm Definitions Item ID FES0MC RO FBES0MC R1 FATEK Automation Corporation ka ts be aa li i el Device Folder Data Con Item Add eee Use Simulation Quality Good Good Timestamp 2015 6 30 FF 03 06 15 2015 6 30 FF 03 06 15 Subquality Not specific Not specific xo Delete Multiply Tools Restore Apply Not Limited No
2. PC data maintenance center ex 192 168 0 119 Setup FatekNetOPC Configurator Launch FatekNetOPC Configurator to configure the device and data items Ww FatekMetOQPC Configurator C FatekKMetQPC_Temp mdb oc fm User Options m ir X 0 Open Save Folder Data Delete Multiply Monitor Item Item F Add Item F Tools F FATER Spare Name Simulate Symbol Register Address Data Type Ell FBSS0MC R0 No R D wo Bl R1 No F l H A Data Conversions H Simulation Signals H Alam Definitions JINT UINT a Mame FES6OMC station No l IP Setting Use Service Call Back Ise Simulation C aN 1670 Timeouts Read msi 1000 Timeouts to suspend 1 100 Write ma 1000 suspend period ims 5000 Enable User Service Call Back enter the device serial number S N and Port IP Setting Use Service Call Back SN 1670 L Fort 200 Click Option Active and click Yes to use the current edited database FATEK Automation Corporation Fatek OPC Server User Manual Active database confirmation dialog F Current active database is CA Users Gtlin Documents FatekhetOPC_Temp mdb Active database is the database that the serrer will load when started Currently edited database is C FatekMetOPC_Temp mdb Do you want to set the current edited database as active database AO a Click Options Setting enable OPC server start as a Windows NT Service au
3. Appendix C Active Call Back Service 1 Introduction User would like to use FatekNet OPC Server to access PLC but the PLC workstation s IP address is acquired using dynamic IP or if it s behind a firewall and access from outside is difficult User can achieve the application by the following steps Note FatekNetOPC Server Version 1 0 4 and later support Active Call Back Service 2 FBs CBEH Setup Please refer to FBS CBEH Operation Manual chapter 8 3 Get Device Serial Number S N Launch Ethernet adaptor Configuration and scan workstations in Ethernet The last two number of Ethernet Address is device serial number S N The serial number in the following figure is 1670 Ox0686H 4 Ethernet adaptor Configuration File Info About Attached Media LAN Internet f R5232 IP Address N ame Ethernet 4ddress OP Mode ae E 192 168 0 153 lt CBEH 1 gt 4c 49 51 01 06 56 Server Device Properties 2 S 2 d Link Test Setup the Data Maintenance Center The Service CallBack Server Ethernet configuration of FBs CBEH must be the same as the data maintenance center ex 192 168 0 119 which the FatekNet OPC Server run on It makes sure that the communication between workstation and OPC server is fine Service CallBack Server Port 15700 IP URL 192 168 0 119 Fatek OPC Server User Manual 3 FatekNet OPC Configurator Setting Install FatekNetOPC Server Install the FatekNetOPC Server application on
4. t Limited
5. tomatically and set Service Call Back Port as 5700 ze etting eneral ES Monitor view tting Update Rate 1000 ima eT ICE J OPC server starts as a Windows NT Service automatically service Call Back Port 5700 A Reboot Reboot the PC system 4 Execute the Active Call Back Program After confirming that the workstation s Service Call Back Server configuration setting is correct you can execute the active call back function To use the active call back function it can be controlled using the registers D3950 and D3951 please refer to FBs CBEH Operation Manual Chapter 2 for detailed descriptions The next figure is a simple control program it uses the XO contact to start up the active call back action When XO is pressed the active call back command code register D3950 will be set to 3359H which will execute the active call back In addition the status of register D3951 can be used to monitor the operation execution of the call back In the example when the connection is successful Y1 will be ON When connection failed Y2 or Y3 will be ON When connection is FATEK Automation Corporation Fatek OPC Server User Manual terminated D3951 must be set to O in order to accept the new call back request command pooo a T i ae __ eg Se 13145 D 03950 i pe pees wil 5 OPC Client Test Before executing active call back program
Download Pdf Manuals
Related Search
Related Contents
Ficha divulgativa sobre Aromaterapia Identificación Descarga DV5-322-550 - Geppert-Band Oricom IP800 User's Manual Installation Manual HP H35000 User's Manual Copyright © All rights reserved.
Failed to retrieve file