1. card OTATTE Blue Red 1 Set up a new MASTER and ACTION CARD by jumper setting LED LED Buzzer Prepare two new cards one for setting as MASTER CARD the other for setting as ACTION CARD Power off the unit Set CLRM to ON position Power on the unit Reader wait for a card to set as MASTER CARD blink _ repeatbeep NEW Present a NEW card to the reader to set as the MASTER CARD SABI Reader wait for another card to set as ACTION CARD blinik __ repeat beep NEW Present another NEW card to the reader to set as the ACTION CARD CARD Reader wait for power Off on Jon continous beep Power off Remove the jumper to set the CLRM to OFF position On the power Reader Back to stand by mode wait for instruction blink J Reader will wait until two new cards was read Blue Red 2 Change the MASTER and ACTION CARD LED LED Buzzer In stand by mode wait forinstruction blnk Present the MASTER CARD to the reader Reader waiting for the MASTER CARD again 2ndtime Joon Present the MASTER CARD again to the reader Reader wait for the MASTER CARD again 3rd time Jon _ repeatbeep Present the MASTER CARD the 3rd time to the reader Reader wait fora NEW card to setas MASTER CARD _ blink_ repeatbeep _ NE Present a NEW card to the reader to set as the MASTER CARD CARD Reader wait for another NEW card to set as ACTION CARD blinik_ repeatbeep Present another NEW card to
2. the reader to set as the ACTION CARD NEW CARD Back to stand by mode wait for instruction blink Reader will wait until two new cards was read MASTER CARD MASTER CARD MASTER CARD Blue Red LED LED Buzzer In stand by mode wait for instruction blink Present an ACTION CARD to the reader Reader wait fora card to be addedordeleted on NEWOR To add Present a new card to the reader To delete Present an authorized card to the reader CardAdded __ijon__ beep Card Deleted __ ijon__ beepbeep Loop again to wait for another card to be added or deleted p0 Reader will back to standby mode if unattend for 10 second 3 Add or Delete a key card ACTION CARD NEW OR AUTHORIZED or CARD Blue Red LED LED Buzzer In stand by mode wait for instruction blink Present the ACTION CARD to the reader Reader wait for the ACTION CARD on the reader 2ndtime on si Present the ACTION CARD the 2nd time to the reader Reader wait for the MASTER CARD for confirmation All authorized key ie hem cards will be removed and then back to stand by mode on repeat beep master Present the MASTER CARD to the reader ARD Delete allcards __ on__ beepbeep Back to stand by mode blinik_ Reader will back to standby mode if unattend for 10 second 4 Remove all authorized key cards ACTION CARD ACTION CARD Ref Appendix A soloF
3. CTION TMR2 TMR1 To select the relay on time with authorization granted TMRO RVSE ON to reverse the operation of the relay CLRM ON to clear the MASTER and ACTION card memory TMR2 TMR1 TMRO FUNCTION OFF OFF OFF Relay on for 1 second on authorization granted OFF OFF ON Relay on for 2 seconds on authorization granted OFF ON OFF Relay on for 5 seconds on authorization granted OFF ON ON Relay on for 10 seconds on authorization granted ON OFF OFF Relay on for 20 seconds on authorization granted ON OFF ON Relay on for 50 seconds on authorization granted ON ON OFF Relay on for 100 seconds on authorization granted ON ON ON Relay state is toggled on each authorization granted ON Jumper shorted OFF Jumper opened Jumper setting for Ci ere 22 gt e pL Pe z slave reader RFID Access Controller with PC Based Time Logger for audit trail amp Attendance Reports soloFace 4 DIMENSIONS 97mm 5 TERMINAL LAYOUT TMRO TMR1 TMR2 RVSE BYPASS SWITCH GND OPEN SW NORMAL OPEN 2 RELAY COMMON NORMAL CLOSE POWER SUPPLY enol 9 12V 300mA DC IN GND DB9 PIN 5 to PIN3 DATA FROM PC DB9 PIN 3 to PIN4 DATA TO PC DB9 PIN 2 to PINS Wi f Power supply atann negative terminal aaesennenpem Power supply positive terminal Zi IN NOD zn f za a RS232 PORT TO COMPUTER www avea cc APPENDIX A soloFace AVeEA Reader setup with the use of Master and Action
4. Ks Programs fm Time Logger brs 4 Favorites X PF Time Logger Documents og Off Rs Start Tea thie TL27308 Time Logger Quick Start 2 Login the Time Logger to start SETUP 1 Setup the password for LOGIN first 4 Define the workgroup 3 Setup the RFID reader Present the ID cards fo the reader if the com port set up correctly the record will be shown on the screen 3 JUMPER SETTING soloFace Standalone Access Controller for 2 730 ID cards Dimensions 97mm x 57mm x 23 5mm 5 Insert the ID card CD ROM to the computer to ADD Cards and Edit Card Information 6 Uploading the authorization table to the reader Time Logger Actions Database Setup J E L JZU Logout Set Password Edit Card Information amp Print Cards amp Print Member List xit About Time Logger Group Definition Readers Offline Reader Manager f Hide On Startup a at Hide to Systray 4 record s Card Information Mode Reader Lock Aug 18 2005 Thu PM 03 10 51 373357 OUT Aug 18 2005 Thu PM 03 11 21 367563 IN DENIED Aug 18 2005 Thu PM 03 11 28 373357 OUT Entrance DENIED Aug 18 2005 Thu PM 03 11 30 373357 DENIED Entrance DENIED Entrance 18 Aug 2005 Thu PM 03 45 07 i There is a 5 position jumper block for configuring the operation of the unit JUMPER POSITION FUN
5. MRO TMR1 and TMR2 with a beep sound On the other hand if an unauthorized card is presented to the TL2730S the red LED and the relay will have no action but with a long beep sound An input contacts is provided if itis shorted the unit will respond the same as an authorized card read Goto 2 6 if use the Time Logger for granting authorization keeping card information and reporting See section 3 5 and 4 2 in Time Logger s User Manual for details 2 4 Use the ACTION card to authorize the ID cards see appendix A section 3 2 5 Record the authorized ID card number and the associated personnel This is for removing the authorized card number in case of card losing 2 6 Power off the reader 2 7 Connect the RS232 cable straight through from the computer to the terminal block of RS232 port See Terminal Layout 2 8 Power on the reader 2 9 Turn on the computer 2 10 Insert the Time Logger CD into your computer s CD ROM drive The Installer will start by itself automatically If the Installer doesn t start automatically you can run the setup exe program to install the software 2 11 The detailed installation manual for the Time Logger will be automatically installed into your computer when you install the application software Follow the installation instruction to finish the installation and follow the Installation Manual of Time Logger from Start for details of Time Logger s Setup Installation Manual of Time ey a Start
6. ace 070301 APPENDIX A soloFace Reader setup with the use of Master and Action card Blue Red 5 Delete an authorized key card number LED LED Buzzer Check the card number the first 10 digits on the left of the card do not need to enter AVEA and the zero digits in the beginning of the number e g card number AVEA 0000310121 005 40197 you only need to enter 310121 In stand by mode blink_ To start deleting Present the ACTION CARD to the reader Reader wait for the MASTERCARD on Present the MASTER CARD to the reader Reader wait forthe ACTION CARD for digit entry blink jon gt gt picgir Start entering the digits Enter the first digit by presenting the ACTION ENTER CARD to the reader Present 1 time for 1 2 times for 2 9 times for ACTION tie 9 or 10 times for zero The buzzer will beep once while presenting the ACTION CARD to the reader once master Present the MASTER CARD to the reader to end the entering of each sa digit including the last digit Repeat above procedure to enter all my digits Present the MASTER CARD to the reader again to inform the reader that you have finished entering all the digits The reader will beep out the number you just entered Start with a long beep and with a Reader wait for confirmation blink Jon Present the ACTION CARD to the reader to confirm the deletion two beeps ID card no delete one long beep slient between each digit e
7. rror Back to stand by mode blink_ Reader will back to standby mode if unattend for 10 second ACTION CARD MASTER CARD MASTER CARD ACTION CARD Enter the first 10 digits Excluding those zeros in the beginning The Sth digit 3 The 6th digit 1 MASTER CARD MASTER CARD ACTION CARD ACTION ACTION CARD CARD ACTION CARD ACTION CARD MASTER CARD The 7th digit O present the ACTION card 10 times ACTION CARD ACTION CARD MASTER CARD ACTION CARD ACTION CARD ACTION CARD ACTION CARD ACTION CARD ACTION CARD ACTION CARD ACTION CARD The 8th digit 1 The 9th digit 2 The 10th digit 1 ACTION ACTION MASTER CARD MASTER CARD ACTION CARD MASTER CARD ACTION CARD CARD CARD Confirm deletion MASTER CARD ACTION CARD END Buzzer beep out the number Diagram 1 Example for Deleting key card number AVEA 0000310121 005 40197 www avea cc
8. soloFace Standalone Access Controller for 2 730 ID cards TL2730S 1 INTRODUCTION The TL2730S proximity access controller control and time recording Dimensions 97mm x 57mm x 23 5mm is a cost effective solution for 2 728 users for access A 9 to 12V DC supply is required to power the reader which has a current consumption of less than 300mA 600mA for dual reader There are three modes of operation in Setup Reader cOM1 AVEA s Reader Options V Reader is connected A IN Mode Single reader use TL2730S for entrance PC based TIME LOGGER with PC ON For audit trail and attendance reports Description of the reader Mode of operation In this mode only a single controller is installed outside the premises An Electric strike can be connected A bypass switch is installed inside the premises pressing it will release the strike While connecting the TL2730S s RS232 port to the computer and running the Time Logger software Windows the program will stamp the clocked date time and card ID into the computer database and show up the associated picture with the specific ID on the computer screen for attendance reports See section 5 for wiring B OUT Mode Dual reader use a TL2730S for Entrance another TL2730S for Exit PC based TIME LOGGER with PC ON In this mode one TL2730S is installed outside the premises for entrance Another TL2730S is installed inside the premises for exit An electric strike and a bypass
9. switch are connected to the OUT reader for exit inside the premises Pressing the bypass switch or presenting the authorized cards will release the strike Clocked data will be sent from both the IN and OUT reader to Time Logger s database if connection is good Wiring Illustration inside or Bat Mode of operation in Setup Reader ASIGS fOr EX in Time Lo RELAY TERMINAL Bypass TO ELECTRIC STRIKE NORMAL OPEN COMMON NORMAL CLOSE Outside for Entrance xxx Jumper setup for slave a Cz AZI Electric 2 s pga oe 1 a O ie n Q QO RS232 PORT Wiring from MASTER to SLAVE TO COMPUTER Master PIN3 toSlave PIN3 MasterPiNGe to Slave PIN6 Master PIN7 to Slave PIN5 Master PIN8 to Slave PIN4 see section 5 for DB9 wiring C CLOCK Mode Single reader all logged records will be stamped as clock entries er OUT slave Reader TL2730S Set u cr 0z9 O Joa E A Je DA RFID Access Controller with PC Based Time Logger for audit trail amp Attendance Reports soloFace www avea cc 2 QUICK START 2 1 Configuring the jumper blocks according to your needs see section 3 2 2 Set up your MASTER and ACTION card according to appendix A section 1 Remember to remove the CLRM jumper after setting up the MASTER and ACTION card 2 3 Remove all authorized key card see appendix A section 4 Present an authorized card to the TL2730S the red LED and relay will turn on as set by T