Home
Droplet , automated LED luminaire User manual v2.0
Contents
1. The Droplet should not be used in humid environments The minimum operation temperature of the Droplet is 0 C 32 F and the maximum is 40 C 104 F The minimum storage temperature of the Droplet is 10 C 14 F and the maximum is 60 C 140 F In case of building in the base of the Droplet make sure there is enough ventilation so the unit becomes not overheated Should the Droplet get overheated in case of a too high environment temperature or not enough ventilation the Droplet M will limit its light output to protect the LEDs Warning during the use of the Droplet make sure that no persons or objects get in contact with the unit in a direct way The pan and tilt travel should always be free to make sure the unit doesn t looses its position 2 5 Maintenance 3 TERMS OF WARRANTY By normal use of the product the manufacturer Xilver B V gives 2 years of warranty Normal use Cleaning means The interior of the Droplet needs low or even no maintenance because the fixture is convection Use within the specifications as prescribed in paragraph 2 1 Install the Droplet cooled and the head of the Droplet is completely closed Use within the specifications as prescribed in paragraph 2 4 Place of usage Taking in consideration the maintenance prescriptions of paragraph 2 5 Maintenance The exterior of the Droplet can be easily whipped of with a slightly moistened cloth Make sure that when doing this
2. 5mm 0 20inch crimp a ferrule on the stripped part for a reliable connection Push the first cable ground out into hole 1 until the cable isolation touches the connector Then tighten screw 1 hand fixed make sure the cable is well fixed check this by pulling it once Repeat this actions for the hot out and cold out hot in and cold in and for the ground in Termination at the end of a DMX line for fixed installation place a resistor of 1200hm between hole 2 and 3 of the data out connector termination plug with a resistor of 1200hm between pole 2 and pole 3 Address settings To control each Droplet individually via DMX each unit should have a unique identity This identity can be given by the DMX address settings There is a dipswitch on the bottom of the fixture to set the DMX address Warning when changing the dipswitch settings of the Droplet make sure the power of the unit is turned off gt lt LNY E Fe Step 3 Addressing the Droplet Dipswitch functions CACR UAE A ee yo nse Position 0 Address setting binary Normal 1 16 32 64 128 256 RGB Compact Table 3 Dipswitch functions The Dipswitch of the Droplet has 12 switches The first nine switches are meant for the DMX address setting Switch number 10 is meant for the method of color mixing and switch 11 defines whether the Droplet functions in normal or compact mode to reduce the number of required channels DMX Mapping H S
3. The unit will cover the whole base plate Fix the unit on the base plate with help of the M3 10 counter sink screws The screws must be placed in the two holes on top of the base near the Xilver logo 2 2 Functionality Movement The Droplet has a 16bit pan and tilt movement in the normal mode and a 8bit in the compact mode In the normal mode the movement is controlled by 5 channels pan tilt pan fine tilt fine and motor speed In the compact mode there is no pan and tilt fine and no motor speed channel The pan and tilt movement is direct driven by stepper motors The travel of the pan movement is 360 and the travel of the tilt movement is 270 Divided over 255 steps the pan moves 1 41 per step and the tilt 1 05 per step with the fine channels each step is divided again in 255 steps The pan and tilt fine are used for precision positioning Motor speed The speed of the pan and tilt movement can be adapted via the motor speed channel When the channel is zero in the compact mode this channel is not available the Droplet M moves at full speed Strobe The Droplet has a 2 channel strobe function in the normal mode The Frequency and the duration are adjustable With frequency you can determine how many times the Droplet should flash per second with the duration channel you can determine how long one flash should take In the compact mode only the frequency function is available Color mixing HSl mode HSI st
4. in a custom designed packing to protect the unit during transport Refuse parcels in damaged condition Use this package always to transport the Droplet The package contains Droplet luminaire User manual Droplet quick reference sheet Mounting plate including 4 Plastic feet 2 M3 10 counter sink screws OI YN YN S 2 1 2 Install the Droplet Make sure the unit is installed in an environment that complies with the prescriptions of paragraph 2 4 Place of usage Install the Droplet in 4 steps See Mounting the Base Plate pe Wiring the Base Plate ae Addressing the Droplet Step Mounting the Droplet on 4 the Base Plate Figure 1 Install the Droplet in 4 steps Step 1 Mounting the Base Plate Make sure that the base plate is always equipped with the 4 plastic feet when using or installing the Droplet Standing Droplet The Base Plate is provided with 4 holes These holes can be used to mount the delivered plastic feet Click the narrow part of the foot into the hole then push the rod into the foot and it is fixed on the Base Plate Hanging Droplet In the centre of the Base Plate is a hole with a diameter of 10mm 0 39inch reserved for the fixing of hooks and clamps for example a G clamp Caution the Nut O ring or Bolt that will be turned to the inside of the Droplet should not be higher than 10mm 0 39 inch Fixed installation There are 2 slotted holes in the b
5. in the preparation of this manual Nevertheless Xilver B V assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in this publication Xilver and Droplet are trademarks of Xilver B V gt lt LN E Fe TABLE OF CONTENTS PY SCIAT ATION Ol COM ormi sesi 8 hee hee E E 2 1 MOC TON Gert ctcestscaceenett E E R 4 2 PROGUCTIGSSCHIDUOM sicehessunsithiar canine vecaiit E ve uecotnra teeter oui 5 Zales COMMUN AUIOMN sree e a E a eee blak amend a a a 5 Ziki UPDACKINS DOPO orokan E a wa den E Mawes 5 Zien ASIANDEDTODIE anes a a a i A 5 Aike FUNCIONAN ranei aa aa a a a aea TE 9 Bes ACCO SONOS A a A N 12 2A PICC Or rU agaa a a a a a a balance decease ohe 12 Ze IWAIMIGNANGCE arrene cov steel a a a a a a a E EA 13 20s SEV WV AN UIE NC S orat a a Oe nena ate eImaae eels 13 3 TESS OWAN aN erer E E T SE EE EA EE dieu EE edema 14 4 APDONGICO S ie a E E E N 15 1 INTRODUCTION Thank you for buying the Xilver Droplet an entirely new concept in lighting technology and lighting application The Droplet is the smallest and first moving LED luminaire with accurate 16 bit fully adjustable pan and tilt With a pan travel of 360 and a tilt of 260 The LED light source is comparable in white output to a 50 Watts halogen reflector bulb and in colors even brighter It has an expected lifetime of 100 000 hours The color combining system en
6. 0 Strobe linear from 1Hz to 25Hz 205 255 81 100 Strobe linear from 25Hz to 50Hz 0 255 0 100 Linear from 0 100 with steps of 1 6 O1 O1 O D Strobe Duration 2 el Po ca Hue Linear fading through all saturated colors if the Saturation channel has value 255 Red Red lt gt Yellow Yellow Yellow lt gt Green Green Green lt gt Cyan Cyan Cyan lt gt Blue Blue 172 212 Blue lt gt Magenta 213 Magenta 214 254 Magenta lt gt Red Saturation 0 255 Intensity Compact mode HSI Function 1 Reset 0 249 0 97 Reserved for special functions Hold for 5 seconds to reset the Droplet Tilt Position from 0 260 Strobe 0 4 0 2 Full on no strobe Frequency 5 204 3 80 Strobe linear from 1Hz to 25Hz 205 255 81 100 Strobe linear from 25Hz to 50Hz 7 2 3 4 5 7 10 11 2 3 4 Saturation 0 255 0 100 Linear fading from white to saturated color chosen via the Hue channel Intensity 0 255 0 100 Linear fading from 0 100 output a B3 5 Hue Primary colors if Saturation channel has value 255 0 Red Red lt gt Yellow Yellow Yellow lt gt Green Green Green lt gt Cyan Cyan Cyan lt gt Blue Blue Blue lt gt Magenta Magenta Magenta lt gt Red Q 5 2 3 Accessories Standard supplied Lenses When delivered the has a beam angle of 10 Additional supplied with each Droplet are two lenses one with a beam angle of 18 and the other with a bea
7. I color mixing R G B color mixing HSI color mixing R G B color mixing Reset Reset Reset Reset Pan Pan Pan Pan Tilt Tilt Tilt Tilt Strobe frequency Strobe frequency Speed Speed Hue Red Pan Fine Pan Fine Saturation Green Tilt Fine Tilt Fine Intensity Blue Strobe frequency Strobe frequency Intensity Strobe Duration Strobe Duration Hue Red Saturation Green Intensity Blue Intensity CONOOR WN Table 4 DMX mapping For example You have 5 Droplets and you want to control them individually If you choose for the normal mode and HSI color mixing each fixture has 11 channels this is also the default setting this means each Droplet uses 11 addresses from the set start address So the first Droplet receives address number 1 the second 12 the third 23 the fourth 34 and the fifth 45 Make sure the Droplets have separated addresses Mode and address settings with the dipswitch Fixture 1 1 2 s 4 5 6 7 l8 9 10072 ijojojojojojojojojo jo jo nue ae eae Were Peo tout 2 olo ililo ololololo Jo Jo reture S 77213 4 516 7 89 10 12 1 7777 0 11 010101010 0 0 Fixture 4 7 2 3 4 5 6 7 8 9 10 11 12 O 1 0 0 0 11 0 0 0 0 0 0 Fixture 5 77213 4 5 6 7 8 9 10 11 12 ilo lil ilolilolo olo Jo o 8 gt lt i E rR Step 4 Mounting the unit on the Base plate Make sure spacer 1 fits into hole 1 and spacer 2 fits into hole 2 Push until the power and date pins slide into the connectors and II on the base plate
8. Red Saturation Green Intensity Blue Intensity CONDOR ON Jx LNF E R 15
9. WY gt lt L nr ES Fe Manufacturer Address t automated LED luminaire User manual v2 0 Drople Droplet EN 55103 1 EN 55103 2 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 EN 61000 4 16 EN 61000 3 2 EN 61000 3 3 EN 60598 K B V Lo Fk CO Fa L E TFT Maastricht March 2003 Ing R Buskens DECLARATION OF CONFORMITY Xilver B V Stationsstraat 44a 6247 BL Gronsveld The Netherlands Declares that the product Is in compliance with the following standards CE measurements in accordance with the EMC and LvD standards Part1 Emission Part 2 Immunity ESD HF immunity EFT Surge CDN Clamp injection Power Magnetic field extended to 10kHz Dips and Voltages Fluctuations Immunity to conducted common mode disturbance Harmonic currents Flicker Electrical Safety for Luminaires 2003 Xilver B V All rights reserved No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of Xilver No patent liability is assumed with respect to the use of the information contained herein Moreover because Xilver B V is constantly striving to improve its high quality products the information contained in this manual is subject to change without notice Every precaution has been taken
10. ables you to produce virtually any color with HSI Hue Saturation and Intensity or RGB color mixing without having multi color shadows It is possible to create either fluent or lightning fast color changes Impressive white and full color strobes can be controlled by the frequency and duration channel Prepared for installation low power consumption light weight small size universal mounting plate no cables or connectors visible extension shaft available and custom housing colors make full integration in its environment possible The luminaire is convection cooled direct driven by stepper motors and needs therefore low maintenance Read this manual carefully Before using the Droplet and use it as a guide to guarantee proper use of this new concept in lighting If you have any questions please contact your supplier This manual will first explain you how to use the Droplet 2 1 Configuration In part 2 2 Functionality you can find a detailed description of all the functions To adapt the Droplet fully to your desires we offer some accessories to extend the applicability The place of usage maintenance requirements and terms of warranty will be quoted in the last 3 paragraphs To this manual is added 1 appendix one sheet that gives you an overview of the technical specifications the dipswitch functions and the DMX mapping 2 PRODUCT DESCRIPTION 2 1 Configuration 2 1 1 Unpack the Droplet The Droplet is delivered
11. ands for Hue Saturation and Intensity The HSI color mixing mode uses 3 channels The Hue channel enables you to choose a color via this way you can choose up to 255 saturated colors The Saturation channel enables you to choose between fully saturated colors and pastel colors The Intensity channel functions like a normal dimmer from no output to full output By Hue and Saturation channel zero and the Intensity channel full max the output of the Droplet is white Changing the Saturation channel to max the output will turn into Red Now you can choose a color with the Hue channel RGB mode RGB is stands for Red Green and Blue Each of these colors use one channel via this channel you can adjust the output of the concerned color To vary the output of the 3 colors you can make each desired color Besides there is an Intensity channel to make it easy dimming the total output of the Droplet If the three color channels are max the Droplet gives no real white you have to vary the output of the separate colors to get white Reset Via the reset channel the Droplet can be given its starting values again so the fixture returns to its point of departure It may occur due to external causes that the Droplet M gets out of its position The reset channel can be used to make sure that the unit follows the given DMX values the right way again To give the Droplet a reset set the reset channel for 5 seconds max Normal mode RGB Ch
12. annel 1 Reset 0 249 0 97 Reserved for special functions eee ee en Hold for 5 seconds to reset the Droplet Position from 0 360 255 Slowest pan and tilt movement 6 Tiltfine 0 255 0 100 _ Fine Positioning of the tilt within an angle of 1 02 7 Strobe 0 4 0 2 Full on no strobe Frequency 5 204 3 80 Strobe linear from 1Hz to 25Hz 205 255 81 100 Strobe linear from 25Hz to 50Hz Strobe 0 255 a Linear from 0 100 with of 1 6 re 9 Red 0 255 0 100 maaan Red output from 0 100 Linear Green output from 0 100 Linear Blue output from 0 100 Compact mode RGB Channel 1 Reset 0 249 0 97 Reserved for special functions te e Hold for 5 seconds to reset the Droplet 3 pit 0 255 0 100 Posiionfom0o 260 Strobe 0 4 2 Full on no strobe Frequency 5 204 80 Strobe linear from 1Hz to 25Hz 205 255 a 100 Strobe linear from 25Hz to 50Hz 5 Reds 0 255 Linear Red output from 0 100 aa 0 255 Linear Green output from 0 100 Z Bue 0 255 Linear Blue output from 0 100 Intensity 0 255 100 Linear overall output from 0 100 Normal mode HSI DMX ch Function Reset Decimal 0 249 Reserved for special functions 250 255 98 100 Hold for 5 seconds to reset the Droplet 0 255 0 255 Slowest pan and tilt movement 255 255 0 2 Full on no strobe Pan Tilt Speed Pan fine Tilt fine Strobe Frequency 5 204 3 8
13. ase plate 1 is reserved for the power cable s and the other IS reserved for the data cable s Before mounting the plate put the wiring for the Droplet trough the holes The base plate can be fixed on a electric wall box It is also possible to mount the base plate on wood or other rigid materials respecting proper and flat mounting of the base plate Use screws with a max diameter of 8mm 0 12inch and make sure the base plate is fixed well The Droplet may be used in virtually any direction standing hanging in vertical direction as fixed on a wall hanging horizontally Caution to guarantee the stability and durability of the unit in horizontal direction make sure that the unit is placed with the logo s on the base placed on the vertical axis Warning A Droplet with extension shaft may only operate hanging max extension length 55cm 21 65inch in vertical direction or standing max extension length 20cm 7 87inch Step 2 Wiring the Base Plate Power Input The Droplet is provided with an internal wide range power supply It operates on a voltage range from 100 to 240VAC at a frequency of 50 to 60Hz no switches that need to be changed Consumption The fixture has a maximum power consumption of 35 Watts Wiring You need a 2 pole power cable of 0 75mm to 1 5mm 18AWG to 16AWG to provide the Droplet with power Use always stranded wire for the power Warning Do not apply power while connecting the
14. cables Connection of the 2 poles into the power connector on the Base Plate a b Fig 2 schematic top view of the Power connector block 6 gt lt LNI E FR Pin Hole Mark Description _ a T ie i o b N Neutral Table 1 power cable specification The power cables should be stripped for 5mm 0 20inch crimp a ferrule on the stripped part for a reliable connection Push the first conductor into hole a until the cable isolation touches the connector Then tighten screw 1 hand fixed make sure the cable is well fixed check this by pulling it strong Do the same for the second conductor Attention after turning off the power of the Droplet wait at least for 5 seconds before turning the power on again otherwise it might occur that the Droplet does not initialize correctly Data Control The Droplet can be controlled by the USITT DMX512 protocol hereinafter called DMX The Droplet uses minimal 7 channels reduced mode HS I and maximal 12 channels normal mode RGB Wiring You need a 3 pole data cable to provide the Droplet with data For cable requirements see the USITT DMX512 protocol Connection of the Data in out into the data connector on the Base Plate picture 1 2 35 4 451 6 Fig 3 schematic top view of the Data connector block Pin Hole Mark Goldin Table 2 Data cable specification a Cold out The data cables should be stripped for
15. m angle of 30 Replacing a lens To replace a lens of the Droplet first take of the front hood by pulling the front hood The existing lens or lens dome can be taken out When you want to have a larger beam angle and the lens dome take out the black synthetic ring Than first place the 18 or 30 lens and than the lens dome The lenses should be placed with the uncurved side pointing to the Droplet and the curved side to the outside Extension shaft The head of the Droplet can be taken of of the base and can be extended this way Xilver B V supplies optional extension shafts for this purpose The following sizes of extension shafts can be delivered out of stock 15cm 5 91inch 25cm 9 84inch 35cm 13 78inch Other sizes can be delivered on request The extension shaft is standard colored in silver RAL 9006 black RAL 9005 or white RAL 9003 On request it can be delivered in any RAL color or even in custom color Warning A Droplet with extension shaft may only operate hanging max extension length 55cm 21 65inch in vertical direction or standing max extension length 20cm 7 87inch Cables The Droplet is standard delivered without cables and connectors On request the Droplet can be pre wired with Data and power cable with the desired connector 2 4 Place of usage The Droplet is mentioned for indoor use only The product may not be exposed to water or extreme hot or cold environments
16. the power of the fixture is turned off Returning of the product in case of warranty always contact your supplier for further instructions 2 6 Safety warnings Warning Do not touch the fixture during operation the temperature of some parts of the fixture can rise up to 80 C 176F Warning Do not stare into the beam of the Droplet the intense light output can cause injuries to your eyes 4 APPENDICES Technical Specifications Voltage 100 240VAC 50 60Hz Power Max 35W Data USITT DMX 512 Protocol XSI Xilver Serial Interface Compact HSI mode 7 channels Compact RGB mode 8 channels Normal HSI mode 11 channels Normal RGB mode 12 channels Standard beam angle 10 supplied lenses 18 and 30 Dimensions O130mm x h185mm 5 11inch x h7 25inch Weight 1 5kg 3 3lbs Pan 360 travel Tilt 260 travel Operation temperature Min 0 C 32 F Max 40 C 104 F Storage temperature Min 10C 14 F Max 60 C 140 F Dipswitch functions CAE Testa TS eT es so E Position 0 Address setting binary Normal 1 16 32 64 128 256 RGB Compact DMX mapping HSI color mixing R G B color mixing HSI color mixing RG B color mixing Reset Reset Reset Reset Pan Pan Pan Pan Tilt Tilt Tilt Tilt Strobe frequency Strobe frequency Speed Speed Hue Red Pan Fine Pan Fine Saturation Green Tilt Fine Tilt Fine Intensity Blue Strobe frequency Strobe frequency Intensity Strobe Duration Strobe Duration Hue