1. Remove all deposits using a stiff brush a brass wire brush is ideal See Fig 14 Check the spark plug gap and adjust if required The correct gap should be 0 7 to 0 8mm Air filter After every 50 hours of running or every 3 months the air filter should be removed examined for deterioration and cleaned Clean the air filter thoroughly using an environmentally friendly water based degreasing agent Refit the air filter when it has dried out fully Warning Never run the engine without the air filter Fuel tank filter Remove the fuel tank filler cap and the filter Fig 15 clean the filter thoroughly using an environmentally friendly water based degreasing agent and re fit 1100w PORTABLE GENERATOR SMK36GEN STORAGE If the generator is not to be used or is to be stored for more than one month the following storage procedure should be carried out Drain all the fuel from the fuel tank and the carburettor ensure that all the fuel has been removed Remove the spark plug and pour approximately one tablespoon full of clean engine oil into the spark plug hole With the ignition turned OFF gently pull on the recoil starter cord several times Re fit the spark plug and continue to pull the recoil starter cord until the piston is on the compression stroke when resistance is felt then stop pulling Store the generator in a dry well ventilated place under a cover to prevent any dust or debris from accumulating on the generator MAI
2. sumo SMK36GEN 1100w PORTABLE GENERATOR SAFETY AND OPERATING MANUAL sumo Congratulations on your purchase of a Sumo generator We want you to continue getting the best performance from it so this handbook includes information on safety handling and care Please retain this handbook in case you need to refer to any of the information in the future Your Sumo generator comes with a 12 month guarantee so should it develop a fault within this period contact your retailer GUARANTEE This Sumo product carries a guarantee of 12 months If your product develops a fault within this period you should in the first instance contact the retailer where the item was purchased This guarantee specifically excludes losses caused due to Fair wear and tear Misuse or abuse Lack of routine maintenance Failure of consumable items such as batteries Accidental damage Cosmetic damage Failure to follow manufacturer s guidelines Loss of use of the goods This guarantee does not affect your statutory rights This guarantee is only valid in the UK 1100w PORTABLE GENERATOR SMK36GEN PLEASE NOTE The generator supplied is NOT suitable for providing power to any electronic products such as computers laptops or televisions etc If in doubt please refer to the specific product manual for advice on supply connection If using for a caravan motor home or boat etc refer to the manufacturers manual regarding c
3. the generator is supplied without oil and must be filled before first use failure to do so will invalidate your guarantee Before checking or refilling oil be sure the generator is put on a stable and level surface with the engine stopped Remove the oil filler cap and check the engine oil level See fig 3 If oil level is below the lower level line refill with suitable oil to upper level line Do not screw in the oil filler cap when checking oil level Change the oil according to the maintenance schedule on page 5 or if contaminated 3 FUELING Check fuel level If fuel level is low refill with unleaded petrol Be sure to use the fuel filter screen on the fuel filter neck Recommended fuel Unleaded petrol The fuel tank should not be filled above the top of the fuel filter as shown in Fig 4 The fuel level can be checked using the gauge on top of the fuel tank 4 STARTING THE GENERATOR ENGINE Before starting the engine make sure that all the electrical loads are disconnected from the generator AC outlet sockets Turn the fuel tap lever to the ON position See Fig 5 Set the choke lever to Choke position Turn the engine ON OFF switch to the ON position See Fig 6 Hold down the generator firmly with one hand on the frame With the other hand grip the recoil starter cord handle See Fig 7 and pull slowly until resistance is felt indicating that the recoil starter is engaged When resistance is felt pu
4. cause drowsiness and death The generator must be mounted on a firm level surface The electrical output load must not exceed the maximum load stated on the rating plate Exceeding the rated load will damage the unit or shorten its life and will invalidate the guarantee The engine must not be run at speeds that exceed the maximum stated on the rating plate Operating an engine at excessive speeds increases the hazard of personal injury Do not tamper with components which may increase or decrease the governed speed Mains extension leads mains supply leads and all electrical equipment must be in good working condition Never operate electrical equipment with damaged or defective mains supply leads Keep the area around the generator clear of obstructions at all times Never locate the generator against a building or near a canvas or plastic structure i e Tents etc Always use the correct fuel mix as stated in the user manual and on the rating plate To prevent fire always stop the engine when refueling and never over fill the fuel tank Always clean up spilt fuel immediately using sand Warning Do not use the generator in or near an explosive atmosphere To prevent an electric shock never operate the machine in rain snow or touch with wet hands Check the fuel system periodically for leaks seals and hoses should be checked for signs of deterioration or chafing Check for loose or missing clamps damaged fuel tank or filler cap All de
5. K36GEN T DC BATTERY CHARGING FUNCTION This function is applicable to 12V battery charging only Disconnect the leads from the battery Loosen the vents on the battery Make sure the battery fluid level is correct Using a hydrometer measure the specific gravity of the battery fluid and calculate the charging time in accordance with the table shown in Fig 10 Attach the 2v charging leads to the battery observing correct polarity Red Positive black Negative Plug the 12v charger lead into the socket on the generator Fig 1 The specific gravity for the fully charged battery shall be charging ime Hr within 1 26 to 1 28 It is advisable to check the specific Batery Battery capacity gravity every hour LAMA 2 Ah HA Aim lor specific gravity and charging time 10 J 4TARh SHA MAINTENANCE Engine oil replacement Place the machine on a level surface and warm up the engine for several minutes Then stop the engine Remove the oil filler cap See Fig 12 Fig 12 Fig 15 Place an oil pan under the engine Remove the oil drain plug See Fig 13 so that the oil can be completely drained Check the oil drain plug gasket oil filler cap and O ring and if damaged replace Reinstall the oil drain plug Add engine oil to the upper level Spark plug After every 50 hours of running the spark plug should be removed Check the colour of the deposits on the end of the spark plug it should be a Tan colour
6. NTENANCE SCHEDULE Remark Pre operation Initial month Every 3 month Every 6 month Every 12 month check daily or 20hours or 50 hours or 100 hours or 300 hours Spark plug Check condition Adjust gap and clean e Replace if required Engine Oil Check oil level Replace Air filter Clean Replace if required Fuel Filter Clean fuel cock filter Replace if required Valve Check and adjust when Clearance engine is cold Fuel line Check fuel hose for cracks or damage Replace if required Exhaust Check for leakage Tighten or system replace gasket if required Check exhaust screen Clean and replace if required Carburetor Check choke operation Cooling Check fan damage system Starting Check recoil starter system operation Decarbon More frequently isation if necessary Fittings Check all fittings and fixtures Fastenings and tighten if required ENGINE TROUBLE SHOOTING CONDITION PROBABLE CAUSE CORRECTIVE ACTION Loose spark plug Tighten plug Insufficient Loose cylinder head compression bolt Tighten bolt Damaged gasket Replace gasket FUEL SYSTEM PROBLEMS Insufficient pulling Pull rope sharply speed for starting rope Foreign matter in No fuel supplied to fuel nk Clean tank combustion chamber Clean fuel line with Clogged fuel line dealers advice No fuel in tank Supply fuel F
7. es Never locate the generator against a building or near a canvas or plastic structure i e Tents etc Always use the correct fuel mix as stated in the user manual and on the rating plate To prevent fire always stop the engine when refueling and never over fill the fuel tank Always clean up spilt fuel immediately using sand Do not use the generator in or near an explosive atmosphere To prevent an electric shock never operate the machine in rain snow or touch with wet hands Check the fuel system periodically for leaks Seals and hoses should be checked for signs of deterioration or chafing Check for loose or missing clamps damaged fuel tank or filler cap All defects should be corrected before further use Always allow the generator to reach full operating speed before connecting any electrical load Always disconnect the electrical load before switching the generator off To prevent surging that may possibly damage electrical equipment do not allow engine to run out of fuel while electrical loads are connected Before transporting the generator in a vehicle drain all fuel to prevent spillage To prevent an electric shock and fire never connect an electrical load with the electrical output switched on Do not connect the generator to any other electrical source Store the generator in a well ventilated area with the fuel tank empty FUEL FILLING SAFETY INSTRUCTIONS Warning Select bare ground for fuelling and move at least 10
8. fects should be corrected before further use Always allow the generator to reach full operating speed before connecting any electrical load Always disconnect the electrical load before switching the generator off To prevent surging that may possibly damage electrical equipment do not allow engine to run out of fuel while electrical loads are connected Before transporting the generator in a vehicle drain all fuel to prevent leakage To prevent an electric shock and fire never connect an electrical load with the electrical output switched on Do not connect the generator to any other electrical source 1100w PORTABLE GENERATOR SMK36GEN The engine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the engine to obtain more performance Both the output voltage and frequency will be thrown out of standard by this practice endangering attachments and the user Store the generator in a well ventilated area with the fuel tank empty SYMBOLS Allow motor to cool before opening the fuel cap The vapour is extremely flammable Wear ear and may ignite on protection contact with hot surface or flames Read the manual Wear eye and dust protection Warning CAUTION Hot exhaust do not touch Connect the generator to earth using a suitable earth spike CAUTION This
9. feet 3m from fuelling spot before starting the engine After refuelling properly tighten fuel cap wipe off any spilled fuel and check for leakage Warning If fuel gets spilled on clothes especially trousers it is very important to change clothes immediately Do not rely on evaporation Flammable quantities of fuel may remain on clothes after a spill for longer than expected Warning Vibrations can cause an improperly tightened fuel cap to loosen or come off and spill quantities of fuel In order to reduce the risk of fuel spillage and fire tighten fuel filler cap by hand as securely as possible Before use always make sure that the fuel cap has been properly tightened Check for fuel leakage while refuelling and during operation If a fuel leak is suspected do not start or run the engine until leak is fixed and spilled fuel has been wiped away Warning The ignition system of your unit produces an electromagnetic field of a very low intensity This field may interfere with some pacemakers To reduce the risk of serious or fatal injury people with a pacemaker fitted should consult their physician and the pacemaker manufacturer before operating this tool Electrical Generator Warning Electrical generator must always be grounded connected to earth Warning Petrol or diesel powered generators must never be used in an unventilated closed spaces The exhaust fumes are highly dangerous and can cause Carbon Monoxide Poisoning which will
10. is a 4 stroke engine Fill with petrol only Do not fill with diesel oil Fuel tank Air filter cover Choke lever AC socket Engine switch Ground earth terminal Oil drain plug Recoil starter AC circuit breaker 10 DC Socket 11 DC circuit breaker 12 Pilot light 13 Voltmeter 14 DC charging leads 15 Spark plug spanner CO CO n Od o1 Co DO 1100w PORTABLE GENERATOR SMK36GEN TECHNICAL DATA AC output 230Vac 50Hz Rated power 0 9kVA Peak power I IKvA Phase Single Power factor cosg Displacement 87cc DC output I2V 5 3A Motor 2 2HP 4 stroke Fuel tank capacity 6L Fuel type Unleaded Petrol Oil type SAE 10W 30 Spark plugtype B6TE NOISE DATA Sound power level declared 93dB The figures quoted are emission levels and are not necessarily safe working levels Whilst there is a correlation between the emission and exposure levels this cannot be used reliably to determine whether or not the actual level of exposure of the workroom the other sources of noise etc i e the number of machines and the adjacent processes and the length of time for which an operator is exposed to the noise Also the permissible exposure level can vary from country This information however will enable the user of the machine to make a better evaluation of the hazard and risk The supplier recommends the use of ear protection at all time Fig 2 OPERATION INSTRUCTIONS Warning Before using
11. ll the cord sharply Continue this procedure until the engine starts When the engine has been successfully started and is running smoothly return the choke lever to the RUN position Warning Before connecting any electrical load to the generator ensure that the load does not exceed the maximum load as stated on the rating plate Ensure that the mains supply lead is long enough to reach the generator without any strain When the generator engine has been successfully started and is running smoothly connect the electrical load into the generator AC output socket 5 STOPPING THE GENERATOR ENGINE Before stopping the engine make sure that all the electrical loads are disconnected from the generator AC outlet sockets Turn the generator ON OFF switch to the OFF position When the generator engine has stopped and before storage turn the fuel tap lever to the OFF position 6 OVER LOAD PROTECTION The generator is fitted with 2 overload protection devices located on the control panel In the event that the load exceeds that stated on the rating plate the overload protection will operate and disconnect the load If the overload protection device is tripped Check the electrical load and if necessary reduce the load The d c overload protection device can be re set by pressing in the re set button See Fig 8 The a c overload protection device can be re set by pressing in the re set button See Fig 9 1100w PORTABLE GENERATOR SM
12. ol outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock 3 Personal safety a Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use safety equipment Always wear eye protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools with your finger on the switch or plugging in power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations f Dress properly Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Loose clothes jewellery or long hair can be caught in moving parts g If devices are provided for the connection of dust extraction and collection facilities ensure these are c
13. onnected and properly used Use of these devices can reduce dust related hazards 4 Power tool use and care a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job better and safer at the rate for which it was designed b Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired c Disconnect the plug from the power source before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users e Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tools operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools f Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control g Use the power tool accessories and tool bits etc in accordance with these instructions and in the manner intended for the particular type of power tool taking in
14. onnection of a generator Do NOT connect into a house ring main circuit SAFETY INSTRUCTIONS CO WARNING Read all instructions Failure to follow all instructions listed below may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS 1 Work area a Keep work area clean and well lit Cluttered and dark areas invite accidents b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bystanders away while operating a power tool Distractions can cause you to lose control 2 Electrical safety a Power tool plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power to
15. roduct 1100W Generator SMK36GEN Complies with the essential health and safety requirements of the following directives 89 336 EEC EMC Directive 2006 95 EC Low Voltage Directive 98 37 EEC Machinery Directive 2000 14 EC Noise Directive Standards and technical specifications referred to EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1 2001 EN 61000 3 2 2000 A2 2005 EN 61000 3 3 1995 A1 2001 EN 61000 3 11 2000 EN 1012 1 1996 EN60204 1 1997 Authorised Signatory Date 22 08 07 Signature Name Peter Harries Powersmith Ltd Quality Manager ISSUE 01 09 07
16. to account the working conditions and the work to be performed Use of the power tool for operations different from intended could result in a hazardous situation 5 Service a Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the power tool is maintained 1100w PORTABLE GENERATOR SMK36GEN ADDITIONAL SAFETY INSTRUCTIONS FOR YOUR GENERATOR Electrical generators must always be grounded connected to earth Petrol or diesel powered generators must never be used in an unventilated closed spaces The exhaust fumes are highly dangerous and can cause Carbon Monoxide Poisoning which will cause drowsiness and death The generator must be mounted on a firm level surface The electrical output load must not exceed the maximum load stated on the rating plate Exceeding the rated load will damage the unit or shorten its life and will invalidate the guarantee The engine must not be run at speeds that exceed the maximum stated on the rating plate Operating an engine at excessive speeds increases the hazard of personal injury Do not tamper with components which may increase or decrease the governed speed Mains extension leads mains supply leads and all electrical equipment must be in good working condition Never operate electrical equipment with damaged or defective mains supply leads Keep the area around the generator clear of obstructions at all tim
17. uel tap not open Open tap ELECTRIC SYSTEM PROBLEMS Engine won t start Spark plug dirty with Remove carbon or carbon or wet with dry spark plug Poor spark Kel Damaged spark plug Replace spark plug Low engine output d P Sufficient Combustion Faulty magneto compression chamber Consult dealer supplied with Improper adjustment fuel of carburetor Good spark Insufficient Pull rope sharply pulling speed for starting rope Wrong grade of Check grade of fuel fuel used Overloading H Check the working Overheating conditions 1 100w PORTABLE GENERATOR SMK36GEN GENERATOR TROUBLE SHOOTING CONDITION No AC output No AC output Output power too high or low PROBABLE CAUSE Tripped circuit breaker Poor connection or faulty lead Broken recepticle Faulty circuit breaker Generator problem Engine RPM set too high or low CORRECTIVE ACTION Reset Check and repair Check and repair No load speed set to 3150rpm Loose component Locate and tighten Internal generator Consult dealer problem SPARES HELPLINE 01302 721791 ENVIRONMENTAL PROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist For further information visit www recycle more co uk 1100w PORTABLE GENERATOR SMK36GEN sumo Declaration of Conformity We Importer Powersmith Ltd BA22 8RT Declare that the p
18. your generator be sure to read the instruction manual carefully 1 LOCATION amp GROUNDING Before using this generator it must be prepared correctly before use Locate the generator on firm level ground away from buildings or other structures ensuring that the exhaust is not obstructed Warning It is advisable to properly earth ground your generator before starting using a wire and a small earth stake Note The wire and earth stake are not supplied with the unit Earth Spike and Cable can be purchased at your local camping supplies or alternatively an Earth spike can be made and it is suggested you get advice from a registered electrical trades person To make a Spike use a Copper tube or Copper Rod 2mm diameter a minimum length of 200mm and with an M6 Machine screw one end The cable used should be a Maximum length of metre and a Minimum of 0mm2 to carry a IOamp load The cable should be attached to the Generator at the Earth point See fig 2 and to the Spike between a flat washer and the Copper with a lock washer under the head of the M6 Machine screw in a similar fashion to the Earth point screw on the generator When placing the Spike into the ground the Generator must not be running and it is suggested that the Spike is pushed into the ground by at least 100mm so that it is firm and a litre of water poured around it to ensure good Earth continuity 1100w PORTABLE GENERATOR SMK36GEN 2 CHECKING THE OIL Warning