Home
TechGrow Humi Twin Manual
Contents
1. so the dehumidifier Source is deactivated The green light is turned on The humidity level gradually starts to rise up to 60 nothing happens Only when the level rises above the humidity set minus the humidity which in this case is 60 5 65 the dehumidifier will be activated and the red light turns on The humidity level now drops and as soon as the value of 60 5 55 has been reached the dehumidifier will be deactivated The light turns green again By adjusting the humidity a stable atmosphere be obtained TechGrow Humi Twin USER MANUAL SWITCHING BETWEEN HUMIDIFY CONTROLLER AND DEHUMIDIFY CONTROLLER Remove the Humi Twin from the wall socket e Plug the Humi Twin back into the wall socket e During start up press the button on the top left once with a pen or paperclip see photo below Now UP humidity controller or DOWN dehumidity controller will appear on the display photo 2 e Press the button repeatedly until the desired function is shown on the display Wait until the Humi Twin is booted The desired function will now be saved This adjustment will be stored even when the Humi Twin has been cut off from power TECHNICAL SPECIFICATIONS Power supply 100 to 240 Volt automatic Power frequency 50 to 60 Hz Consumption 3 Watt with sensor without humidifier dehumidifier Maximum load 1500 Watt max 6A Range humidity set 10 90 relativ
2. adjust de value with the rotary button 0 5 e wait for 3 seconds the new set value will be saved automatically The display will now return to the main screen TechGrow Humi Twin USER MANUAL OPERATING THE TECHGROW HUMI TWIN HUMIDITY CONTROLLER When the humidity in a room drops below the set value setpoint the humidifier dehumidifier source will be activated After a while the humidity will change and when it has reached the set value the source will be deactivated again EXAMPLE 1 The Humi Twin is set on humidifying UP The humidity is set at 60 The humidity is at 5 The current humidity level in the room is for example 70 which is higher than the humidity set so the humidifier source is deactivated The green light is turned on The humidity level gradually starts to drop to 60 nothing happens Only when the level drops below the humidity set minus the humidity which in this case is 60 5 55 the humidifier will be activated and the red light turns on The humidity level is now rising and as soon as the value of 60 5 65 has been reached the humidifier will be deactivated By adjusting the humidity a quiet and stable atmosphere can be obtained EXAMPLE 2 The Humi Twin is set on dehumidifying DOWN The humidity set is at 60 The humidity is at 5 The current humidity level in the room is for example 50 which is lower than the humidity set
3. _TechGrow a lt Humi Twin imidity Controller gt Z gt TechGrow Humi Twin USER MANUAL CONGRATULATIONS You have just purchased the TechGrow Humi Twin humidity controller This easy to use humidity controller is by far the best in its class thanks to its completely digital technique SPECIAL FEATURES e Plug Play placeable in small to very large rooms e Extremely accurate external humidity sensor produced by Sensirion e Adjustable between 10 90 relative humidity e The sensor takes a measurement every second e Switches the humidifier dehumidifier on off using a 230V relay e Memory in case of power outages for setpoint and hysteresis e Automatic 110V 230V detection e LED indicates when the Humi Twin is active e Automatically detects if the humidity sensor is connected correctly in case of broken cable bad connection e LCD display e Connecting the sensor is done with a standard network cable UTP Included is a 5 meter cable This cable can be replaced by a longer UTP cable INSTALLATION 1 It is recommended to mount the humidity sensor on a wall close to the humidifier dehumidifier with a minimum distance of 50 cm The sensor must be placed approximately 1 meter above the floor For this use the enclosed mounting bracket Connect the sensor to the Humi Twin with the supplied UTP cable Plug the Humi Twin in to a 230V wall socket Wait unti
4. e humidity Range humidity O 5 humidity Measurement frequency 1 measurement per second TechGrow Humi Twin USER MANUAL Notes 8 Ne Ak of El accurate CUSSI erat A WOKS 1 with an al 51115141 0 Deo a feedback mo a Opal oie pone
5. l the Humi Twin is booted takes approx 12 seconds Plug the humidifier dehumidifier into the socket of the Humi Twin Ready YN It is not recommended to mount the Temp RH sensor in such a way that it catches direct light The housing of the sensor can reach high temperatures and wrong values could be shown The sensor must be placed approximately 1 meter above the floor For this use the enclosed mounting bracket placed left or right Sensor can be Sensor 50 T cm Humidifier dehumidifier 1 TechGrow Humi Twin USER MANUAL When activating the TechGrow Humi Twin humidity controller the following will appear on the display sequentially TechGrow Humi Twin photo 1 UP or DOWN photo 2 V1 0 photo 3 MEANING OF THE LED Green LED on continually humidifier dehumidifier is switched off Red LED on continually humidifier dehumidifier is switched on Red LED blinking no sensor or the sensor is damaged photo 6 ADJUSTING THE TECHGROW HUMI TWIN HUMIDITY CONTROLLER ADJUSTING SETPOINT PHOTO 4 For setting the appropriate humidity use the rotary button to set the desired humidity level e Use the left rotary button to adjust the setpoint 10 90 e Wait for 3 seconds the new set value will be saved automatically The display will now return to the main screen ADJUSTING HYSTERESIS BANDWIDTH PHOTO 5 For adjusting the hysteresis use the rotary button on the right e
Download Pdf Manuals
Related Search
Related Contents
Télécharger Sharp XG-C335X data projector MAnuAL - Mares Premiership Rugby Views User Manual Genesys Series - Daitron[ダイトエレクトロン株式会社] カタログ Da-Lite 76181 projection screen palmOTDR User`s Manual RIDGID R82238N Use and Care Manual ML7105 User`s Manual Copyright © All rights reserved.
Failed to retrieve file