1. Detail A Detail B Points to Notice e An elbow and a waste connection hose of 50 mm will be delivered with the product but an edge lath and other accessories are not included e The place where the product will be installed should be straight e An airing and access window should be left if the hydromassage bathtub is installed without panels e During the installation of the panels the adjustment of the leg set should be carried out according to the height of the panel e The electronical system is running with 220 volt with earth connection For its connection a 3x2 5 mm cable should be used e The product should be protected with an appropriate ampere fuse for Duo Maxi System 20 ampere for Duo Soft System 16 ampere for Aqua Maxi and Aqua Soft Systems 10 ampere and the amper fuse should be closed when it is not used e The faucet should not be applied on the pump of the hydromassage bathtub e The spout should be min 17 cm if the faucets are installed to the wall e Because of the technical features of the product it should definitely be used with the 5601084 coded waste amp siphone No other waste amp siphone alternative is available e Handgrip application for this product is not available e For the cleaning of the acrylic bathtub look at the User Manual e Waste connection fuse wall hangers and user manual are delivered with the product Faucet Applications ANY APPLICATION OF TABS ON THIS BATHTUB IS NO
2. Aqua Maxi Aqua Soft IMPORTANT For the electrical connection of the hydromassage bathtubs earth connection is necessary The cable connection of the PHASE hyrdomassage bathtubs should be E NEUTRAL 220v YELLOW GREEN erouno applied as shown in the Figure e Check whether the yellow green earth cables bound with the metal parts placed under the hydromassage N we bathtubs are connected to all legs Pump Electronic Control Panel X AirJets Aqua Soft Easy 7i Transformer E Waste If the bathtub is used without panels the following airing and access Blw Blower e Water Jets windows should be applied R1 Access window min 400x400 mm SCB Control Button e Micro Water Jets R1 Airing and access window min 400x400 mm A Air Controler na Underwater Light R2 Access window min 400x400 mm R2 Airing and access window min 250x250 mm i Push Button Water Suction Filter VitrA Bathtubs Co Cumhuriyet Mah 13 Sok No 10 Sekerpinar 41400 Gebze Kocaeli Turkey Tel 90 262 648 95 00 pbx Fax 90 262 658 85 94 always keeps the rights to make any changes on the brod ct E mail vitrabathtubs export eczacibasi com tr Q Eczacibasi October 2008 www vitrakuvet com tr VitrA Bathtubs Co COMFORT RECTANGULAR 170x75 cm v if GAY
3. Size cm 170x75 Height cm 56 Weight kg 20 Front Panel Weight kg 4 8 a Side Panel Weight kg 2 1 o M Volume It 203 Available massage systems Duo Soft Aqua Maxi Aqua Soft Aqua Soft Easy Plan H n n e 3 je 8 2 Side View Front View if e As shown in Figure Plan the wall hangers details A B are used to fix the product to the wall It is suggested to use the wall hangers to rigid the bathtub Detail A Detail B Points to Notice e An elbow and a waste connection hose of 50 mm will be delivered with the product but an edge lath and other accessories are not included e The place where the product will be installed should be straight e An airing and access window should be left if the hydromassage bathtub is installed without panels e During the installation of the panels the adjustment of the leg set should be carried out according to the height of the panel e The electronical system is running with 220 volt with earth connection For its connection a 3x2 5 mm cable should be used e The product should be protected with an appropriate ampere fuse for Duo Maxi System 20 ampere for Duo Soft System 16 ampere for Aqua Maxi and Aqua Soft Systems 10 ampere and the amper fuse should be closed when it is not used e The faucet should not be applied on the pump of the hydromassage bathtub e The spout should be min 17 cm if the faucets are installed to the wall e Because of t
4. 84 coded waste amp siphone No other waste amp siphone alternative is available e For the cleaning of the acrylic bathtub look at the User Manual e Vaste connection fuse wall hangers and user manual are delivered with the product Faucet Applications ANY APPLICATION OF TABS ON THIS BATHTUB IS NOT POSSIBLE gt On The area where the waste outlet 2 50 mm can be placed in Ideal position of the waste outlet 50 mm The end point of the waste outlet should not be cut out and should be left at least 50 mm above the surface The area 200 mm where the waste outlet should not be left Hot amp cold water inlet for the wall taps Measures for electrical connection of whirlpool tubs There is no need to leave additional space for the silicone during the installation process It is enough to prepare the required area according to the size of the product Perspective Massage Systems Duo Soft Aqua Maxi Aqua Soft Aqua Soft Easy Pump Electronic Control Panel X Air Jets l 7 Transformer p Waste IMPORTANT e For the electrical connection of the hydromassage bathtubs earth connection Blw Blower e Water Jets is necessary The cable connection of the PHASE BLUE CB Control Button e Micro Water Jets hyrdomassage bathtubs should be aaa RAL in sroun applied as shown in the Figure
5. COMFORT RECTANGULAR DOUBLE ENDED 190x90cm Size cm Height cm Weight kg Front Panel Weight kg Side Panel Weight kg Volume It Available massage systems 190x90 56 28 237 Duo Maxi Duo Soft Aqua Maxi Aqua Soft Aqua Soft Easy Plan 09S SIG 900 ll 560 515 1900 470 Side View Front View j j e As shown in Figure Plan the wall hangers details A B are used to fix the product to the wall It is suggested to use the wall hangers to rigid the bathtub Detail A Detail B Points to Notice e Comfort Rectangular Doubleended 190x90 is a symmetrical model The siphone hole and siphone controlling handle are in the middle Therefore it is convenient for double ended usage e An elbow and a waste connection hose of 50 mm will be delivered with the product but an edge lath and other accessories are not included e The place where the product will be installed should be straight e An airing and access window should be left if the hydromassage bathtub is installed without panels e During the installation of the panels the adjustment of the leg set should be carried out according to the height of the panel e The electronical system is running with 220 volt with earth connection For its connection a 3x2 5 mm cable should be used e The product should be protected with an appropriate ampere fuse for Duo Maxi System 20 amper
6. PHASE CB Control Button 5 Micro Water Jets hyrdomassage bathtubs should be lt a croun applied as shown in the Figure e Check whether the yellow green earth A Air Controller Underwater Light cables bound with the metal parts placed under the hydromassage E W Me PB Push Button Water Suction Filter bathtubs are connected to all legs If the bathtub is used without panels the following airing and access windows should be applied R1 Access window min 400x400 mm R1 Airing and access window min 400x400 mm R2 Access window min 400x400 mm R2 Airing and access window min 250x250 mm VitrA Bathtubs Co Cumhuriyet Mah 13 Sok No 10 Sekerpinar 41400 Gebze Kocaeli Turkey VitrA Bathtubs Co A m Tel 90 262 648 95 00 pbx Fax 90 262 658 85 94 always keeps the rights to make any changes on the frodi E mail vitrabathtubs export eczacibasi com tr Q Eczaci basi October 2008 www vitrakuvet com tr COMFORT RECTANGULAR DOUBLE ENDED 180x80cm Size cm 190x90 Height cm 56 Weight kg 125 Front Panel Weight kg 5 5 Side Panel Weight kg 3 Volume It 196 2 Available massage systems Duo Soft E Aqua Maxi Aqua Soft Aqua Soft Easy Plan 800 09S SIS Side View Front View j j e As shown in Figure Plan the wa
7. T POSSIBLE gt On The area where the waste outlet 50 mm can be placed in Ideal position of the waste outlet 50 mm The end point of the waste outlet should not be cut out and should be left at least 50 mm above the surface The area 200 mm where the waste outlet should not be left Hot amp cold water inlet for the wall taps Measures for electrical connection of whirlpool tubs There is no need to leave additional space for the silicone during the installation process It is enough to prepare the required area according to the size of the product Perspective Massage Systems Duo Soft Aqua Maxi Aqua Soft Aqua Soft Easy Pump m Electronic Control Panel x Air Jets I 7 Transformer Waste IMPORTANT e For the electrical connection of the hydromassage bathtubs earth connection Blw Blower e Water Jets is necessary The cable connection of the m PHASE CB Control Button 5 Micro Water Jets hyrdomassage bathtubs should be lt a croun applied as shown in the Figure e Check whether the yellow green earth A Air Controller x Underwater Light cables bound with the metal parts placed under the hydromassage Laie PB Push Button Water Suction Filter bathtubs are connected to all legs If the bathtub is used without pane
8. e for Duo Soft System 16 ampere for Aqua Maxi and Aqua Soft Systems 10 ampere and the amper fuse should be closed when it is not used e The faucet should not be applied on the pump of the hydromassage bathtub e The spout should be min 17 cm if the faucets are installed to the wall e Handgrip application for this product is not available e Because of the technical features of the product it should definitely be used with the 5601084 coded waste amp siphone No other waste amp siphone alternative is available e For the cleaning of the acrylic bathtub look at the User Manual e Vaste connection fuse wall hangers and user manual are delivered with the product Faucet Applications ANY APPLICATION OF TABS ON THIS BATHTUB IS NOT POSSIBLE gt On The area where the waste outlet 2 50 mm can be placed in Ideal position of the waste outlet 50 mm The end point of the waste outlet should not be cut out and should be left at least 50 mm above the surface The area 200 mm where the waste outlet should not be left Hot amp cold water inlet for the wall taps Measures for electrical connection of whirlpool tubs There is no need to leave additional space for the silicone during the installation process It is enough to prepare the required area according to the size of the product Perspective Massage Systems Duo Maxi Duo Soft
9. e Check whether the yellow green earth A Air Controller re Underwater Light cables bound with the metal parts placed under the hydromassage Aika PB Push Button Water Suction Filter bathtubs are connected to all legs If the bathtub is used without panels the following airing and access windows should be applied R1 Access window min 400x400 mm R1 Airing and access window min 400x400 mm R2 Access window min 400x400 mm R2 Airing and access window min 250x250 mm VitrA Bathtubs Co Cumhuriyet Mah 13 Sok No 10 Sekerpinar 41400 Gebze Kocaeli Turkey VitrA Bathtubs Co A Tel 90 262 648 95 00 pbx Fax 90 262 658 85 94 always keeps the rights to make any changes on the frodi E mail vitrabathtubs export eczacibasi com tr Q Eczacibasi October 2008 www vitrakuvet com tr COMFORT RECTANGULAR 170x80 cm V if GAY Size cm 170x80 Height cm 56 Weight kg 22 Front Panel Weight kg SA a Side Panel Weight kg 3 e Volume It 245 Available massage systems Duo Soft Aqua Maxi Aqua Soft Aqua Soft Easy Plan 800 1700 e 09S SIG 560 515 Side View Front View if e As shown in Figure Plan the wall hangers details A B are used to fix the product to the wall It is suggested to use the wall hangers to rigid the bathtub
10. he technical features of the product it should definitely be used with the 5601084 coded waste amp siphone No other waste amp siphone alternative is available e Handgrip application for this product is not available e For the cleaning of the acrylic bathtub look at the User Manual e Waste connection fuse wall hangers and user manual are delivered with the product Faucet Applications ANY APPLICATION OF TABS ON THIS BATHTUB IS NOT POSSIBLE gt On The area where the waste outlet 50 mm can be placed in Ideal position of the waste outlet 50 mm The end point of the waste outlet should not be cut out and should be left at least 50 mm above the surface The area 200 mm where the waste outlet should not be left Hot amp cold water inlet for the wall taps Measures for electrical connection of whirlpool tubs There is no need to leave additional space for the silicone during the installation process It is enough to prepare the required area according to the size of the product Perspective Massage Systems Duo Soft Aqua Maxi Aqua Soft Aqua Soft Easy Pump m Electronic Control Panel x Air Jets I 7 Transformer Waste IMPORTANT e For the electrical connection of the hydromassage bathtubs earth connection Blw Blower e Water Jets is necessary The cable connection of the m
11. ll hangers details A B are used to fix the product to the wall It is suggested to use the wall hangers to rigid the bathtub Detail A Detail B Points to Notice e Comfort Rectangular Doubleended 190x90 is a symmetrical model The siphone hole and siphone controlling handle are in the middle Therefore it is convenient for double ended usage e An elbow and a waste connection hose of 50 mm will be delivered with the product but an edge lath and other accessories are not included e The place where the product will be installed should be straight e An airing and access window should be left if the hydromassage bathtub is installed without panels e During the installation of the panels the adjustment of the leg set should be carried out according to the height of the panel e The electronical system is running with 220 volt with earth connection For its connection a 3x2 5 mm cable should be used e The product should be protected with an appropriate ampere fuse for Duo Maxi System 20 ampere for Duo Soft System 16 ampere for Aqua Maxi and Aqua Soft Systems 10 ampere and the amper fuse should be closed when it is not used e The faucet should not be applied on the pump of the hydromassage bathtub e The spout should be min 17 cm if the faucets are installed to the wall e Handgrip application for this product is not available e Because of the technical features of the product it should definitely be used with the 56010
12. ls the following airing and access windows should be applied R1 Access window min 400x400 mm R1 Airing and access window min 400x400 mm R2 Access window min 400x400 mm R2 Airing and access window min 250x250 mm VitrA Bathtubs Co Cumhuriyet Mah 13 Sok No 10 Sekerpinar 41400 Gebze Kocaeli Turkey VitrA Bathtubs Co A m Tel 90 262 648 95 00 pbx Fax 90 262 658 85 94 always keeps the rights to make any changes on the frodi E mail vitrabathtubs export eczacibasi com tr Q Eczaci basi October 2008 www vitrakuvet com tr
Download Pdf Manuals
Related Search
Related Contents
Gigabyte GV-N26OC-896H GeForce GTX 260 graphics card H25.3.1(25年2月中) Oki 5200ne Printer User Manual American Power Conversion CTEG4-240MB-5 User's Manual iKUBE user manual - iKUBE - Portable Solar Generators Samsung NT200B5C User Manual (Windows 7) [mymail / FRA] Guide d`utilisation PDF user manual - s3.amazonaws.com Copyright © All rights reserved.