1. scope with measurement reading Input impedance Input 1 1 MQ 12 pF with BB120 20 pF 2 pF with BB120 3 pF Input 2 1 MQ 10 pF with BB120 18 pF 2 pF with BB120 3 pF Vertical Voltage ranges 50 mV div to 500V div 1 2 pixels Vertical sensitivity resolution 5 mV div to 500V div 8 bit 256 levels Bandwidth input 1 voltage Bandwidth input 2 current DC to 20 MHz at inputs or with VPS40 probe Opt 1 MHz with TL24 Leads DC to 15 kHz at inputs 10 kHz with 80i 500s Current Clamp Coupling DG AC NOR 3 a OOO TimeBase modes Normal roll single TimeBase ranges 60 s div to 20 ns div 0 4 1 pixel Sampling rate Record length min max samples Trigger source Trigger mode 25 MS s 512 per channel Input 1 or Input 2 or Automatic selection Automatic Connect and View Free Run Single Shot Connect and View Advanced automatic triggering that recognizes signal patterns and automatically adjusts triggering timebase and amplitude Automatically displays stable pictures of complex and dynamic signals like motor drive and control signals Pre trigger Up to 10 divisions Measurement readings per channel selectable Volts amp Amps DC AC AC DCrms Peak max Peak min Peak min max Frequency Duty cycle or Phase Pulse Width or Crest factor Ohms Diode Continuity Capacitance Ohms Diode voltage Continu
2. 0 00 kA 1250 kA 1 10 counts Frequency 10 0 Hz to 15 0 kHz 0 5 2 counts CF Crest Factor 1 0 to 10 0 5 1 count Power W VA VAR Reactive Power 1 phase and 3 phase 3 conductor balanced loads PF Power Factor DPF Displacement Power Factor 250 W 2 50 kW 25 0 KW 250kW 2 50 MW 25 MW 250 MW 625 MW 1 56 GW 0 00 to 1 00 0 00 to 0 25 0 25 to 0 90 0 90 to 1 00 2 6 counts Total Power 4 4 counts Fundamental Power 0 04 not specified 0 04 0 03 Hz Frequency fundamental 40 0 to 70 0 Hz 0 5 2 counts Harmonics Volts Amps Watts Fundamental V A 3 2 counts W 5 2 counts 2 to 3lst Harmonic V A 5 3 counts W 10 10 counts Frequency of fundamental Phase K Factor Amps amp Watts THD Sags amp Swells Recording times selectable Vrms actual Vrms max min AC DC 32 to 51st Harmonic 40 Hz to 70 Hz Volt amp Amps between Fund amp Harmonic Watts between Volt Fund amp Amps Harmonic 1 0 to 30 0 0 00 to 99 99 4 min to 16 days 5 000 V 50 00 V 500 0 V 1250 V Arms actual Arms max min AC DC 50 00 A 500 0 A 5 000 KA 50 00 kA V A 15 5 counts W 30 5 counts 0 25 Hz 2nd 3 51st 15 Fund 5 51st 15 10 3 8 counts Readings 2 10 counts Cursor readings 2 12 counts Cu
3. Fluke 43B Power Quality Analyzer VOLTS 7 AMPS 7 HERTZ uc nin BOO nz The Fluke 43B Power Quality Analyzer performs the measurements you need to maintain power systems troubleshoot power problems and diagnose equipment failures All in a rugged handheld package e New NiMH Battery provides extended operating time of 6 5 hours e Combines the most useful capabilities of a power quality analyzer multimeter and scope e Calculates 3 phase power on balanced loads from a single phase measurement e Trends voltage current frequency power harmonics and captures voltage sags transients and inrush current e Monitoring functions help track intermittent problems and power system performance e Records two selectable parameters for up to 16 days e 20 measurement memories to save recall screens and data with cursor readings e FlukeView Software can log harmonics and all other readings over time and provides a complete harmonics profile up to the 51st harmonic e Measures resistance diode voltage drop continuity and capacitance e Users applications manual and power quality video to help answer tough questions e Complete package with voltage probes and 400 A current clamp FlukeView Software and optically isolated interface cable e 3 year warranty on the Fluke 43B 1 year on accessories VOLTS AMPS HERTZ CcfBw uc S00 e Voltage and current waveforms e True rms voltage and current e Frequency e On
4. Voltage Probe Probes 7 BNC Adapters EEI 4 mn PO Ra SOTK Thermocouple Module i Test Probes 80T 150U Universal Temperature Probe 1400s 400 A AC Current Clamp PAC91 Parallel Printer Adapter l f OC4USB Optically Isolated USB TLK225 SureGrip Master Accessory Interface Adapter Test Lead Kit S J BP120MH Rechargeable NiMH Battery TL220 63 Test Lead Set Pack installed TL221 Extension Lead Set PM8907 Line Voltage Adapter Battery TL223 Plectical Teat Lead Sei Charger SW43W FlukeView Power Quality Fluke Keeping your world Analyzer Software for up and running Windows Power Quality CD with e User s manual Fluke Corporation e Power quality video PO Box 9090 Everett WA USA 98206 e Application guide Fluke Europe B V PO Box 1186 5602 BD Getting started guide Eindhoven The Netherlands Shielded Banana to BNC adapter For more information call In the U S A 800 443 5853 or Fax 425 446 5116 In Europe M East Africa 31 40 2 675 200 or Fax 31 40 2 675 222 In Canada 800 36 FLUKE or Fax 905 890 6866 From other countries 425 446 5500 or Fax 425 446 5116 Web access http www fluke com 2005 Fluke Corporation All rights reserved Trademarks are the property of their respective owners Printed in U S A 11 2005 1266142 D ENG N Rev H Printed on recycled paper
5. ity shorts gt 1 ms Capacitance Temperature 500 0 Q 5 000 KQ 50 00 KQ 500 0 KQO 5 000 MQ 30 00 MQ O to 3 000 V Beeper on at lt 3092 50Q 50 00 nF 500 0 nF 5 000 pF 50 00 pF 500 0 pF 100 0 C to 400 0 C 200 0 F to 800 0 F 0 6 5 counts 2 5 counts 2 10 counts 0 5 5 counts Max current max open circuit volt 0 5 mA lt 4 V all functions above Memory Number of screens 20 Optical Isolated Interface To printer Supports HP LaserJet DeskJet Epson FX LQ and Postscript printers with optional PAC91 Printer Adapter Cable To PC FlukeView Power Quality Analyzer software with PM9080 Interface Adapter included FlukeView Power Quality Software Hardware requirements PC or 100 compatible with Windows 95 98 Me 2000 NT4 0O 1 pixel inrush time 250 Requires optional temperature accessory IHRUSH Tar ar0112s4p ea BACK RECALL HO e Inrush current up to 500A with supplied current probe e Use cursors to measure inrush current timing SETUP RANGES MOUE TRIGGER e Connect and View scope for quick waveform display e 20MHz bandwidth with optional 10 1 voltage probe 15kHz on current channel with optional current clamp alce r li m a itis a ea bal fe ma a ri o wa e FlukeView Power Quality Analyzer
6. rsor Readings Average 2 10 counts Recording Recording times selectable 4 min to 16 days Parameters Choose one or two parameters from one of the groups below V A Hz Line Voltage Current Frequency Power Watts VA VAR PF DPF Frequency Harmonics THD Volts Fund amp Harmonic Amps F amp H Watts F amp H Freq H H of total Phase H KF Ohms Ohms Diode Continuity Capacitance Temperature C or F Scope DC Voltage DC Current AC Voltage AC Current Frequency Pulse Width or Phase Duty cycle or Peak max Peak min Peak min max Crest Factor Transients Minimum pulse width Useful bandwidth input Number of transients Voltage threshold settings Reference signal Vpeak min Vpeak max at cursor Rated 600 V CAT II DC to 1 MHz with test leads TL24 20 50 100 200 above or below reference signal After START the Vrms and frequency of the signal are measured From these data a pure sinewave is calculated as reference for threshold setting 10 V 25 V 50 V 125 V 250 V 500 V 1250 V 5 of full scale Inrush Current Ranges Accuracy Current ranges selectable 1A 5 A 10 A 50 A 100 A 500 A 1000 A Inrush times selectable ls 5s 10s 50s 100 s 5 min Cursor readings A peak max at cursor 1 and cursor 2 5 of full scale Time between cursors 4 to 235 pixels 0 2 2 pixels Scope dual channel
7. screen graphics show you how to set up 3 phase power measurements 100 ku 95 EVAR er e Watts power factor displacement power factor Cos o VA and VAR e Voltage and current waveforms HARMONICS 66 2 BO 7A 204 kF gt 1 5 9 13 1r 21 25 29 33 3 41 45 49 VOLTS WATTS Cy e Voltage current and power harmonics e Up to 51st harmonic e Total harmonic distortion THD e Phase angle of individual harmonics Specifications Accuracies are stated as percentage of reading counts without probes unless otherwise noted Specifications are valid for signals with a fundamental between 40 and 70 Hz SAGS amp SWELLS deao Max coas Uz Cel min Fs br OMar 06 2001 14 34 14 7 19 max 71 5 A 708 min e Measurements are always automatically recorded to instantly show changes over time e Use cursors to read time and date of sags and swells TRANSIENTS 013 Kua max 016 kut min Mar 20 2001 06 01 06 REF 119Urms 59 55Hz H TRANSIENT H e Catch voltage transients and waveform distortion down to 40 ns e Catch and save up to 40 transients e Correlate the cause of transients with time and date stamps Input Characteristics Ranges Accuracy Input impedance 1 MQ 20 pF Voltage rating 600 Vrms CAT III Volt Amps Hertz True rms voltage AC DC 5 000 V 50 00 V 500 0 V 1250 V 1 10 counts True rms current AC DC 50 00 A 500 0 A 5 000 KA 5
8. software included e Capture measurement screens for professional looking reports e Log readings to your computer disk drive e Works with Windows word processing spreadsheet and analysis software e Windows 95 98 Me 2000 NT 4 0 General Specifications Power Line voltage adapter battery charger included Installed battery Rechargeable NiMH pack 4 8v dc Operating time 4 hours Charging time 7 hours Environmental Temperature O C to 50 C 32 F to 122 F Environmental MIL 28800E Type 3 Class III Style B Enclosure IP51 dust drip water proof Mechanical Data Size H x W x D 232 x 115 x 50 mm 9 1 x 4 5 x 2 inches Weight 1 1 kg 2 5 lbs incl battery pack Safety For measurements on 600 Vrms Category III installations Pollution Degree 2 in accordance with EN 61010 1 ANSI ISA 82 01 1994 CAN CSA C22 2 No 61010 1 04 Surge protection 6 kV on input 1 and 2 Warranty 3 years parts and labor on Fluke 43B 1 year on accessories Ordering Information Optional Accessories Fluke 43B Power Quality Analyzer C789 soft Carrying Case A 80i 110s 100A AC DC Current Probe A 1200s AC Current Clamp HARMONICS Included Accessories i1000s 1000A AC Current Clamp E ee C120 Hard Case i2000flex Flexible 2000A AC Current TL24 Test Leads Probe Te AC20 Industrial Test Clips i3000s Clamp On AC Current Clamp AC85 Large Jaw Alligator Clips VPS40 10 1

Download Pdf Manuals

image

Related Search

Related Contents

Oce North America OP1030 User's Manual  Ettan IPGphor 3 Control Software  ちらし:PDF  Brugsanvisning  Video Editing Explanation  MANUAL DE MONTAGEM/MANUAL DO PROPRIETÁRIO Este  REGELBARE LÖTSTATION PLS 48 A1  Multidisciplinary Care Record - School of Computer Science and  751 LANKOLATEX  Sony ICF-C470MK2 Operating Instructions  