Home

WL-UU551 User manual

image

Contents

1. i w m gt iy Sw i u connecting sockets MYCHWAY iz PATENT REGISTRATION PIRATED RESERVED Accessories 40k cavitation head Sixpolar RF Laser Tripolar RF Head Bipolar RF Vacuum Multipolar RF Basal Operation 1 Put all the accessories well and connect them to the host Insert the Sixpolar laser RF work head to A 2 Insert 40k cavitation work head to B 3 Insert Tripolar RF work head to C 4 Insert Bipolar RF work head to D 2 Insert power supply to F Turn on general power switch E Interface LCD screen 40k cavitation Explode Procedure Apply the cavitation theory use the 40Khz Ultrasound to make intense vibration which causes a inner explosion in the fat issues thus get rid of lipocyte it can effectively break down stubborn and deep fat decrease lipocyte quantity and its size The diathermal of the low frequency ultrasound can promote lipocyte and tissues liquid flow which help drainage of fatty acid waste and toxin through lymph system 1 Clean the parts and applied gel on fleshly parts e g abdomen hip thigh the amount depend on moving flexibility of the cavitation explode 1 Click the lt I gt to choose the mode 40k cavitation time mode and energy will be displayed 2 Energy adjust Click lt 4 gt lt 5 gt for adjusting energy lt 4 gt for decreased lt 5 gt for increased 3 Time adjust Click lt 2 gt lt 3 gt for adjusting energy lt 3 gt
2. click lt 1 gt to choose the mode which you like When we do every mode we can click lt 6 gt to let the laser light turn on and off 4 Set works time 20 minutes for each parts 5 The system default laser is start state click lt 6 gt the laser function is closed Note Do not let the laser light straight shine upon the eyes in case of eyes hurt 6 Applied gel on skin needed nursing the electrode probe move slowly on skin if there is too much fat you can increase the output intensity 7 The machine will pause automatically if the setting time 1s over 8 Clean the leftover with hot towel use warm towel to clean the work head Bipoar RF head for eye 1 1 Click lt 1 gt Adjust the mode to Bipolar RE 2 Energy adjust Click lt 4 gt lt 5 gt for adjusting energy lt 4 gt for decreased lt 5 gt for increased 3 Time adjust Click lt 2 gt lt 3 gt for adjusting energy lt 3 gt for decreased lt 2 gt for increased 4 Mode Transfer Click lt 6 gt first make it to the interface for mode transfer then click lt 1 gt to choose the mode which you like When we do every mode 2 Set works time 20 minutes for each parts 3 The system default laser is start state click lt 6 gt the laser function is closed Note Do not let the laser light straight shine upon the eyes in case of eyes hurt 4 Applied gel on skin needed nursing the electrode probe move slowly on skin if there is too much fat you can increase the output
3. intensity 5 The machine will pause automatically if the setting time is over 6 Clean the leftover with hot towel use warm towel to clean the work head Caution for RF 1 Beautician should wear insulated gloves during operation 2 Do not wear any aglet both for the beautician and the users 3 The electrode probe must be fully in contact with skin 4 Do not make the RF electrode stay on any part without moving Keep it moving on skin slowly 5 Skin around eyes and forehead is very thin the RF output intensity should be relatively weakened 6 Do not contact skin with unipolar when using of bipolar tripolar hexpolar work head otherwise it will produce pulse discharge gel paste Ect Products like gel maybe evaporated into a mist 7 Do not let the laser light straightly shine upon the eyes in case of eyes hurt Vacuum Multipolar RF 1 1 Click lt I gt Adjust the mode to Vacuum 2 Energy adjust Click lt 4 gt lt 5 gt for adjusting energy lt 4 gt for decreased lt 5 gt for increased 3 Time adjust Click lt 2 gt lt 3 gt for adjusting energy lt 3 gt for decreased lt 2 gt for increased 4 Mode Transfer Click lt 6 gt first make it to the interface for mode transfer then click lt I gt to choose the mode which you like When we do every mode 2 Set works time 20 minutes for each parts 3 The system default laser 1s start state click lt 6 gt the laser function 1s closed Note Do not let the laser light
4. straight shine upon the eyes in case of eyes hurt 4 Applied gel on skin needed nursing the electrode probe move slowly on skin 1f there 1s too much fat you can increase the output intensity 5 The machine will pause automatically if the setting time is over 6 Clean the leftover with hot towel use warm towel to clean the work head Forbidden Group 1 People with heart disease or high blood pressure or configured cardiac peacemaker 2 Patients with acute inflammation asthma deep vein thrombosis thyroncus cancer 3 People with hemorrhagic disease trauma or who is bleeding 4 Pregnant women 5 Medical Plastic parts or parts with artificial in filling inside 6 People with metal inside the body include metallic tooth 7 Patient with skin inflammation or with edema 8 People with an abnormal immune system 9 Numb or intensitive to heat Technical Specification Screen 5 4 Color TFT Display Rated input voltage AC220V 240V 50HZ ACI10V 120V 60Hz Rated input power 350VA Cavitation frequency 40KHz Cavitation Power up to 60W Cavitation tip 60mm diameter RF for body RF frequency 3MHz RF power up to 150W RF type six polar RF tip 65mm diameter RF for face RF frequency 1MHz RF power up to 100W RF type tripolar RF tip 25mm diameter RF for eye RF frequency 1MHz RF power up to 60W RF type bipolar RF tip 25mm diameter Lipolysis laser 635nm Lipolysis power 100mw Photon Light Red LED light Wavelengt
5. WL UU55 User manual Catalog WAI coaens one cae ean renee Tee Parts instruction Accessorles cece ea aa aa aa aa a eee eee ee eee ee Bascal T eT h u pesa aduana bat di eee e wete 5 AQkedvi tation Explode procedure eeunenn 5 Cautron Tor Sti AK e ose Lak iii iL ree RUS eee 6 Cal Oracion Tor AOR a re pe je av ja ee 6 ST EDO lar R WOR DOO E aa rena a boat ene SAS Bed 6 dbs canta Doe AR WOR LOO renate rad ee NG T Bipolar Ab Or ON TTT 8 Caution Tor MSN RP vann Sree cred dete ea ete ee as dh O Forbidden voj o Re m mph a ramena a 8 Teenmnicialk parameters smb neee nea eR Re eae 9 PAC NO MS GLA vaneen eee AN ae Ras ew iga mt 9 PAO sea dk sk is end s DESI rena a bo doii 10 Warning Dear user Thanks for using our company s products in order to fully make use of the products we sincerely suggestion follows 1 Please read the instruction in detail and keep it well for further reading and consulting 2 Please follow the instruction to fit and operate the machine correctly 3 Please do not remove and change any accessories of the machine 4 It forbids others to open and remove the mainframe except the authorized people in the company 5 It forbids others to change and maintain the machine except the professional people 6 Please contact us if there is any trouble during operation Parts Introduction ia elt Tn of 176176089 H E HEL E lt lain le i T f a m KEF 5 i
6. ays to do the treatment Sixpolar RF for body 1 Click lt I gt Adjust the mode to Sixpolar RE 2 Energy adjust Click lt 4 gt lt 5 gt for adjusting energy lt 4 gt for decreased lt 5 gt for increased 3 Time adjust Click lt 2 gt lt 3 gt for adjusting energy lt 3 gt for decreased lt 2 gt for increased 4 Mode Transfer Click lt 6 gt first make it to the interface for mode transfer then click lt I gt to choose the mode which you like When we do every mode we can click lt 6 gt to let the laser light turn on and off 2 Set works time 20 minutes for each parts 3 The system default laser is start state click lt 6 gt the laser function is closed Note Do not let the laser light straight shine upon the eyes in case of eyes hurt 4 Applied gel on skin needed nursing the electrode probe move slowly on skin if there is too much fat you can increase the output intensity 5 The machine will pause automatically if the setting time is over 6 Clean the leftover with hot towel use warm towel to clean the work head Tripolar RF head for face 1 Click lt 1 gt Adjust the mode to Tripolar RE 2 Energy adjust Click lt 4 gt lt 5 gt for adjusting energy lt 4 gt for decreased lt 5 gt for increased 3 Time adjust Click lt 2 gt lt 3 gt for adjusting energy lt 3 gt for decreased lt 2 gt for increased 4 Mode Transfer Click lt 6 gt first make it to the interface for mode transfer then
7. for decreased lt 2 gt for increased 4 Mode Transfer Click lt 6 gt first make it to the interface for mode transfer then click lt I gt to choose the mode which you like When we do every mode we can click lt 6 gt to let the laser light turn on and off 2 Beautician hold the cavitation explode work head to move slowly on skin in circle or beeline repeatedly and the other hand push the fat towards the work head 3 Do not use on back avoid using on bones 4 Do not use on uterus part when a woman do abdomen treatment during menstruate should be avoid 5 The machine will pause automatically if the setting time is over Please click any place the screen according to the hint 6 Clean the leftovers with the hot towel use warm towel to clean the cavitation explode work head Caution for using 40k 1 Applied enough gel on skin need treated 2 Do not stay unmoved on any part of your body do not stay on bones 3 The total treatment time for daily should be within 30minutes 4 There will be ultrasonic only when you start the working mode of 40k 5 Do not allowed to be placed under the state of no load to avoid the damage caused by high heat 6 40k work head can be used on fresh part of the body Do not use for facial If the skin is sensitive or becomes unhealthy Calibration for 40k 1 We can click the lt l gt and lt 6 gt to calibrate the frequency of 40k cavitation head so that get the best result and comfortable w
8. h 640nm 5nm Power 15W Packing Include Main maichine x1 unit 40KHz cavitation head x lunit Sixpolar RF head for body xl unit Tripolar RF head for face x lunit Bipolar RF head for eyes x lunit Power supply wire x lunit Holder x lunit Key switch x 1 unit FAQ 1 How quickly will I see the results of treatment Most clients experience few cm of reduction in circumference after a single session with increasing results after each visit The results may vary with different tissue structure treatment area age metabolism medications and changes in hormones Proper diet and increased physical activity will certainly improve and help to maintain the results Between 8 and 12 sessions you will be able to appreciate the results from the third session on 2 Is repeat treatment required Generally one treatment per a single area is usually adequate to achieve the required results And we suggest that you had better have 8 and 12 sessions Normally it is a Long lasting treatment However maintenance of this fat loss is dependent on a healthy diet and exercise 3 How does it feel Most clients consider the procedure painless and comfortable There may be however a slight discomfort due to the specific noise experienced but it poses no harm and disappears as soon as you are not in contact with the applicator You may also experience a little warmth during the treatment It is very normal if you experience with this aboved problems i
9. n which is doing the treatment of Real 40Khz cavitation

Download Pdf Manuals

image

Related Search

Related Contents

Samsung VC240 Εγχειρίδιο χρήσης  Betriebsanleitung Mode d'emploi Gebruiksaanwijzing  StarTech.com 5.25” USM Storage Bay with 2.5” SATA USM / USB 3.0 Hard Drive Enclosure  WIRELESS PRESENTER with FLASHLIGHT  La lecture et l`écriture en centre de loisirs  特記仕様書(施工条件明示一覧表)  Quadrifoglio B Manual  Hama 00105373 padlock  ITNS-500 - Innovative Technology  