User Manual - Advanced Power Care

image

Contents

1. With rack installation the use of support brackets L shaped support guides available at rack cabinet dealers is recommended 3 2 Wall version BOX Attach the Bypass to the wall bracket as shown in the figure below position the slotted L bracket without fully tightening the two screws The figure below shows the drilling template for installing the BYPASS on the wall 182 320 6 Adjust the L bracket the slots to ensure the cables remain secured as shown in the figure lt L bracket 3 3 Installation instructions Before connecting the BYPASS to the UPS ensure the following conditions are met 1 Donot position in areas exposed to direct sunlight or hot air 2 Keep the ambient temperature between 0 C and 40 C 3 The relative humidity in the environment must not exceed 90 4 Avoid dusty environments 3 4 Connecting the BYPASS HHP Rack version rear view TN
2. The plug outlet configurations vary depending on the versions 15 2 1 Operating modes The BYPASS has a manual switch SWITCH with which you can choose the operating mode SWITCH K EN 7 UPS MAINS UPS i A BYPASS i RACK NI mains uPs SWITCH X NI L BOX 10A 16A UPS BYPASS SWITCH SWITCH to select the load power supply from the UPS or mains BYPASS position MAINS light green on Mains present at the bypass input UPS light green on UPS voltage present at the bypass input 3 INSTALLATION N B the installation of a 16 circuit breaker curve upstream from the BYPASS is required This protection is necessary if required by the UPS user manual WARNING observing the neutral N and phase P indications relating to plugs and outlets the BYPASS inserted in a system does not change the existing neutral system The neutral system will still be modified if an isolation transformer is present For versions with output cable the blue wire identifies the neutral cable while the yellow green wire identifies the earthing cable SOCKET PLUGS S o Ed I 7 LI _ VA 7 EN NA N OOO 6 a 9907 ee az x E 2 L F J L II 3 1 Rack version
3. fool Z j N D oo TO UPSOUTPUT TO UPSINPUT MAINSINPUT TO UPSOUTPUT TO UPSINPUT MAINSINPUT LOAD LOAD an TN 10 aly TI LI 2 aw fous NN YE 16A Version 10A Version N B The plug outlet configurations vary depending on the versions 1 Check that the SWITCH is in the BYPASS position 2 Connect the load to the output outlets Load N B The plug outlet configurations vary depending on the versions 3 Connect the UPS input to the outlet located on the BYPASS marked TO UPS INPUT Connect the UPS input to the plug located on the BYPASS marked TO UPS OUTPUT 5 Connect the power cable to the plug marked MAINS INPUT 20 6 At this point the load is powered Check that the MAINS green light is on If it is not check that there are no switches open upstream from the BYPASS Turn on the UPS follow the instructions in the UPS user manual Push the SWITCH to UPS Check that the green light is on If it is not make sure that the UPS is turned on and check all connections with it 4 USING THE BYPASS 4 1 Instructi
4. MANUAL BYPASS Manuale D uso User s Manual ENGLISH USER MANUAL 1 INTRODUCTION AND SAFETY 14 1 1 INTRODUCTION 14 1 2 PRECAUTIONS AND SAFETY RULES 14 2 PRESENTATION 15 2 1 OPERATING MODES 16 3 INSTALLATION 17 3 1 RACK VERSION 17 3 2 WALL VERSION BOX 18 3 3 INSTALLATION INSTRUCTIONS 19 3 4 CONNECTING THE BYPASS 20 4 USING THE BYPASS 21 4 1 INSTRUCTIONS TO BE FOLLOWED FOR UPS MAINTENANCE 21 42 BYPASS LIMITATIONS OF USE 21 5 TECHNICAL SPECIFICATIONS 22 13 1 INTRODUCTION AND SAFETY 1 1 Introduction Thank you for choosing our product The manufacturer is particularly specialised in the development and manufacture of uninterruptible power supplies UPSs and related accessories This manual contains detailed instructions for installing and using the BYPASS To get maximum performance from your device please read and follow the instructions described herein Keep this manual close to the BYPASS Reproduction even partial of any part of this manual is forbidden unless authorised by the manufacturer For improvement purposes the manufacturer reserves the right to change the product described at any time without notice 1 2 Precautions and safety rules This part of the manual contains the precautions to be followed closely as far as SAFETY is concerned a The device must always be earthed during use Do not remove the plug from the power supply as this would disconnect the safety earth for all devices powere
5. d b The BYPASS has HAZARDOUS electrical voltages inside it Any maintenance must ONLY be performed by trained personnel c Do not connect the neutral output to the neutral input or to earth as this may damage the UPS connected to the BYPASS itself d The output outlets may be live even if the UPS is not connected to the mains e Do not allow water liquids in general and or other foreign objects to get inside the BYPASS Do not expose the device to direct sunlight or heat sources f The separable power cable is intended as a sectioning device Be sure to leave adequate free space near the cable connection for easy disconnection g Observing the neutral and phase indications relating to plugs and outlets the BYPASS inserted in a system does not change the existing neutral system h Do not connect the UPS to plugs or outlets other than the dedicated ones on the BYPASS Incorrect installation could cause malfunctions or failures of the UPS and the load connected to it 2 PRESENTATION The purpose of a BYPASS is to connect the load to the mains with minimal interruption to allow the ordinary and extraordinary maintenance of the UPS The BYPASS makes it possible to switch the utilities connected to it onto the main power line in the event that the UPS is switched off or becomes blocked The BYPASS is supplied for installation in rack cabinets or for installation on the wall or above the 10 or 16A UPS BOX Box 16 N B
6. ons to be followed for UPS maintenance Instructions to be followed when it is necessary to repair replace or carry out maintenance on the UPS Move the SWITCH to the BYPASS position Turn off the UPS Disconnect the UPS Reconnect the UPS new or repaired Turn on the UPS Move the SWITCH to the UPS position gt pos When the SWITCH is in the MAINS position any disturbance of the mains affects the load powered by the BYPASS This means that in the event of a mains blackout even if the UPS is on the load is disconnected 4 2 BYPASS limitations of use The BYPASS can power multiple loads at the same time provided that the total current output is less than 16A for the Box 16A and Rack versions and 10A for the Box 10A version 21 5 TECHNICAL SPECIFICATIONS MODEL 10 Rated voltage Vac 220 230 240 Switching time ms typical 3 maximum 5 Maximum current MODEL BOX 16A Rated voltage Vac Switching time ms Maximum current 3 Ambient temperature 0 40 Humidity Protective devices Dimensions H x W x D Weight g Rated voltage Vac Switching time typical 3 maximum 5 Maximum current A Ambient temperature C Humidity Protective devices Dimensions H x W x D 44 1U x 440 x 215 Weight ii 22 OMNBYM10A2LUA