Home

LightMaster-Pro Stand-Alone Software User Guide

image

Contents

1. Es Gals Ej s T r uv v u v amp jeeee eeee eeee eeee a Sa e Factory Supplied Cable 7 6 standard 50 maximum For distances over 50 a PAK Programming Access Kit is required Consult factory for Personal Computer equipped with LightMaster Pro software specific requirements Figure 2 1 Direct Connect Link LightMaster Pro User Manual Version 1C 1 1 05 Communications HGH FCC Code 68 compliant cord RJ 11 Male Connector Modem Port Personal Computer equipped with LightMaster Pro software n BE EE oki ol m s 22 amp 8
2. 2 3 LightMaster Pro User Manual Version 1 1 1 05 Communications 2 1 Communication Methods There are two possible methods for linking a LightMaster controller to a PC e Direct Connect connect the factory sup plied cable consult factory for alterate cable between a COM port on your computer and the RS 232 port on the LightMaster CPU board See Figure 2 1 e On board Modem if equipped connect the LightMaster s on board modem and your computer s modem via a direct analog telephone system no digital sys tems enable remote communication See Figure 2 2 LightMaster Controller RS 232 Port LIGH 2 2 Communication Features Once linked with a LightMaster you can Check the current status of relays relay groups and switch inputs Turn individual relays or relay groups ON or OFF e Sweep relays in the LightMaster ON or OFF Download parameters from your PC to the LightMaster Download the clock settings from your PC to the LightMaster NOTE make sure the time and date on your PC is appropriate for the LightMaster s location This is a special concern when programming a remote LightMaster e Upload parameters from the LightMaster to your PC e Trigger presets E l Sep E asi
3. 2 27 NCC 07252474 nS 707 C7 Analog Telephone System E RJ11 Phone Jack RJ11 Phone Jack FCC Part 68 compliant cord Figure 2 2 On board Modem Link LightMaster Pro User Manual 2 2 Version 1C 1 1 05 Communications 2 3 Sample Procedures Connect with a LightMaster and Sweep ON relays The physical link is a direct connect RS 232 Connect with the LightMaster controller See Figures 2 4 5 6 1 After starting LightMaster Pro and powering up the controller point amp click on Connect See Figure 2 1 2 When the Communications screen appears point amp click on the LightMaster node address pull down menu to select the Node Address of the LightMaster 3 Select the COM port used to connect RS 232 cable from your PC to the LightMaster 4 Select the Connect to LightMaster button ILC LightMaster File 812 Setup Edit Document About HOT Master LIGH Sweep all controller Relays ON See Figures 2 7 6 9 1 Select EDIT from the menu bar then Relay Outputs from the pull down menu 2 Point amp click on Relay Status 3 Point amp click on Relays On button Verify that the relay states have changed 2 4 Virtual Keypad Feature While you are connected to the controller you have the option of using the virtual key pad feature of the software to program the controller Pressing the Virtual Keypad but ton will display a
4. 3 1 o Enter the Settings Off 3 2 3 4 Save the Settings to FIG biet ri v on n 3 15 3 5 Connect with the Controller and Download Settings 3 17 Section 4 Appendix zx Installing 1 WIN presses R 1 2 Minimum Computer 1 Recommended Installation 1 LightMaster Pro User Manual Version 1C 1 1 05 LIGH Section l Program Description and Installation ILC LightMaster Eile Connect Setup Edit Document About ILC LightMaster Single Panel Configuration Software Version 6 21 800 922 8004 www ilc usa com Copyright 2003 ILC File Name None Disconnect ted LightMaster Pro User Manual Version 1C 1 1 05 section 1 lable Contents Pro Section 1 Program Description and Installation 1 1 TA TT TT 1 1 1 2 Starting LightMaster 1 1 bo Men Bor 1 1 oe I 1 2 LightMaster Pro User Manual Version 1 1 1 05 Program Description and Installation Pro 1 0 Overview LightMaster Pro is a windows based lighting control software package designed for a stand alone LightMaster lighting control panel Using point and click c
5. Go to RUN from the START menu on your computer Click BROWSE navigate to your CD drive and select Setup for LightMaster Pro 2 Follow the directions on the screen to complete the installation 3 Proceed to Starting LightMaster Pro Troubleshooting LightMaster Pro installation fails reboot and re install the software Call ILC Technical Support for further assistance 1 952 829 1900 Please have your system information ready 1 2 Starting LightMaster Pro To Start LightMaster Pro double click on the ILC LightMaster Icon The home screen shown in Figure 1 1 will appear 1 3 Home Screen Menu Bar Options The menu bar across the top of the screen offers the following options point amp click on the option you want to invoke e File Use FILE to create a new file open save current system entries parameters to your hard drive and to exit the program Connect Use to connect your PC to the lighting controller You can set the system Clock retrieve data issue commands and program parameters on line via Connect Setup permits you to define the number of I O cards and types of optional add on modules the LightMaster is equipped with Edit enter LightMaster s operational parameters Document This feature allows you to organize and manipulate data for importing into other data based and spreadsheet programs About displays the Home screen and the software revision level and th
6. www ilc usa com www ilc usa com www ilc usa com www ilc usa com www ilc usa com www ilc usd com www ilc usd con gt ites ENERGY SAVING LIGHTING CONTROLS Intelligent Lighting Controls Inc Lighting Control Software for LightMaster Panels in Stand Alone Applications Was SOFTWARE GUIDE Includes setup installation and programming LightMaster Pro software for the ILC LightMaster lighting controller in stand alone applications www ilc usa com m www ilc usa com www ilc usa com www ilc usa com m Lighting Control Software for LightMaster Panels in Stand Alone Applications LIGH SOFTWARE USER GUIDE STAND ALONE Version 1C 1 1 05 INTELLIGENT LIGHTING CONTROLS og 5229 Edina Industrial Boulevard Minneapolis Minnesota 55439 Phone 952 829 1900 FAX 952 829 1901 BELGIO 1 800 922 8004 Table of Contents PIG Section 1 Program Description and Installation E 1 1 1 1 1 2 Starting LightMaster 1 1 1 3 Men Bar OPOS erronei eeen a 1 1 1 2 Section 2 Communications 2 1 Comminicatlon 2 1 22 2 1 2 3 Sample 2 3 24 Keypad 2 3 Section 3 Getting Started APEC TION n oca 3 1 3 2 Project DESCHIOTION
7. Timer 4 OFF 10 minutes after sunrise Timer 5 ON at 6 45 AM Timer 6 OFF 7 30 PM Off sweeps are once every 3 hours Preset 1 relays 1 and 3 ON relays 2 and 4 OFF Preset 2 relays 1 and 3 OFF relays 2 and 4 ON LightMaster Pro User Manual Version 1 1 1 05 1 2 3 4 Getting Started 3 3 Enter the Settings Line Start LightMaster Pro 1 Power up your computer 2 Double click on the LightMaster Pro icon on your desktop to bring up the LightMaster Pro Home screen Setup LightMaster See Figure 3 1 1 Point amp click on Setup 2 When the Setup screen appears point amp click 8 8 Relay Card Total 8 button ILC LightMaster File 812 Setup Edit Document About taster LIGHZ Pro Configure the Switches See Figures 3 2 3 1 Select EDIT from the menu bar then select Switch Inputs from the pull down menu 2 Point and click on Devices 3 Point and click on Configure LightSync Devices to access the configuration screen 4 Point and click on Select Device then click on LSYNC 02 5 Point and click on the device type pull down menu and select 6 button 6 Ensure that the resulting display shows that all 6 inputs are Momentary P B ILC LightMaster Single Panel Configuration Software 800 922 8004 www ilc usa com File Name None Version 6 21 Copyright 2008 ILC Disconnected Figure 3 1 Home Screen LightMaster Pr
8. Connected Figure 2 9 Disconnect Screen ILC LightMaster Virtual Keypad File Connect Setup Edit Document About LIGHTMAS TER THU 01720703 US e PM EDIT C3 20035 1EC File Name None Connected Figure 2 10 Virtual Keypad Screen LightMaster Pro User Manual 2 6 Version 1 1 1 05 Section 3 Getting Started HGH Section 3 Getting Started ILC LightMaster File Connect Setup 2 2 Document About Relay Outputs Switch Pilots LightSync Status Timers Il Configure LightSync Devices Set Times LightSync Input To Relay Control Presets Input AJ Control Add On Modules Special Functions gt Pro ILC LightMaster Single Panel Configuration Software Version 6 21 800 922 8004 www ilc usa com Copyright 2008 ILC File Name None Disconnected LightMaster Pro User Manual Version 1C 1 1 05 Getting Started Table of Contents Pro Section 3 Getting Started isse 3 22 3 1 3 3 Enter The Settings 3 2 3 4 Save the Settings qa Hle usce 3 15 3 5 Connect with the Controller and Download Settings 3 17 LightMaster Pro User Manual Version 1C 1 1 05 Getting Started 3 1 Introduction The easiest way to develop proficiency using Lightmaster Pro is to practice Let s program a Lightmaster You will
9. File name Building LM LightMaster Data Files 1 2 Save as type File Name None LightMaster Pro User Manual Version 1C 1 1 05 Connected Figure 3 17 Save As Screen 3 16 Getting Started 3 5 Connect with the Controller Download the Settings From the Home screen point amp click Connect When the Connect screen See Figure 3 18 appears point and click on the address pull down menu to select the Node Address of the LightMaster Select the COM port used to connect the RS 232 cable from your PC to the LightMaster Select the Connect to LightMaster button ILC LightMaster Connect File Connect Setup Edit Document About N LIGH Master Verify that your PC has the proper date and time for the LightMaster s location Select Set LightMaster Clock to adjust date and time See Figure 3 19 Point and click on Download Settings to LightMaster to send your settings to the controller disconnect from the controller point and click on Disconnect From LightMaster NOTE If you choose you can enter or change settings online Remember to upload them to your hard drive to stay curent LightMaster Node Node 01 Indirect Connection Communications COMI C C COM3 C COM4 5232 Modem File Name None Disconnecte
10. an action table for the 8 relays ILC LightMaster Configure LightSync Devices File Connect Setup 2 Document About LIGH Pro 4 Point and click on the action menu for Relay 01 and select And 5 Point and click on the sub address pull down menu and LSYNC 02 2 6 Point and click on the action menu for Relay 02 and select On And Off 7 Repeat steps 4 6 to designate settings for other sub addresses and their associated relays tw Relay Outputs Switch Pilots Local Inputs Timers Set Times Presets Add On Modules Special Functions gt File Name None 4 LightSync Inputs gt input 2 Momentary nput3 Momentary PB Input4 Momentary PB Input5 Momentary PB Input 6 Momentary PB th Button LightSync Status Configure LightSync Devices LightSync Input To Relay Control LightSync Input To Group Control Connected Figure 3 4 Switch Input Pull Down Menus LightMaster Pro User Manual Version 1C 1 1 05 Getting Started LIGH ILC LightMaster LightSync Input To Relay Control File Connect Setup Edit Document About LSYNC 02 6 Button Momentary PB RELAY OT No Action JRELAY02 No Action RELAY 03 No Action RELAY O04 No Action RELAY OS No Action RELAY On And Off RELAY 07 No Action RELAY 08 No Action File Name None Connected 2 Figure 3 5 LightSync Input to Relay Co
11. get the most good out of this section if you actually perform the procedures as you read them In this example you will be programming a LightMaster 8 located in a school direct connected to the PC via the RS 232 port The LightMaster is addressed as Node 1 the LightSync switch is addressed as Node 2 There are 4 basic tasks 1 Document the project 2 Enter the desired settings off line 3 Save the settings to a file 4 Download the settings to the LightMaster Node 01 LIGH 3 2 Project Description The LightMaster is to control 8 circuits Two hall circuits four auditorium circuits and two outside lighting circuits The inside circuits are to be controlled from a six button LightSync switch In addition the hall circuits are to turn ON in the morning OFF at night and be subject to after hours OFF sweeps The auditorium circuits are to be subject to two preset patterns and OFF sweeps The outside lights are to be turned ON by an Astro timer and OFF by a late night normal timer This control scheme is summarized in control schedule Control Schedule Area Controlled switch Hall 5 6 and OFF sweeps Hall 5 6 and OFF sweeps Auditorium OFF sweeps Auditorium OFF sweeps Auditorium OFF sweeps Auditorium OFF sweeps Outside Lights 1 2 3 4 Outside Lights Timer 1 ON 10 minutes before sunset Timer 2 OFF 11 45 PM Timer 3 ON 45 minutes before sunrise
12. software version of the controller s keypad that can be used to program the LightMaster ILC LightMaster Single Panel Configuration Software 800 922 8004 www 5 File Name None Version 6 21 Copyright 2003 ILC Disconnected Figure 2 4 Home Screen LightMaster Pro User Manual Version 1C 1 1 05 Communications HGH ILC LightMaster Connect File Connect Setup Edit Document About LightMaster Node Node 01 Indirect Connection Communications COMI 95232 C IRDa COM3 Modem C Connect To LightMaster File Name None Disconnected 2 Figure 2 5 Connect Screen ILC LightMaster Connect File Connect Setup Edit Document About On Line Functions LightMaster Firmware Revision C come Da Time 04 55 27 PM C UMS er Date Thu 01 30 03 zm 1 0 Installed 08 Inputs Relays Add On Card None Virtual Keypad Download Settings Upload Settings From LightMaster LightMaster File Name None Connected Figure 2 6 Connect Screen LightMaster Pro User Manual 2 4 Version 1C 1 1 05 Communications HGH ILC LightMaster Connect File Connect Setup 5218 Document About Relay Outputs 4 Relay Status Switch Inputs Group Status u
13. d Figure 3 18 Connect Screen LightMaster Pro User Manual Version 1 1 1 05 3 17 Getting Started ILC LightMaster Connect File Connect Setup Edit Document About Communications Disconnect From LightMaster File Name None IGH On Line Functions LightMaster Firmware Revision 1 TrTETET TE Tra RIT Te T 7 PREN lel T2 T T ToT1 7 To 7 To 3T Time 04 55 27 PM Date Thu 1 30 03 1 0 Installed 08 Inputs Relays Add On Card None Virtual Keypad Download Settings To Upload Settings From LightMaster LightMaster Connected 2 Figure 3 19 Connect Screen after LightMaster Pro User Manual Version 1 1 1 05 3 18
14. e ILC Corp 800 number Program Description and Installation 1 4 Edit Options The edit options offered on the home screen are Relay Outputs use this option to check relay relay group status control relay relay groups from your PC and define certain relay parameters for example whether a relay is to be subject to a blink alert Switch Inputs use this option to check local and LightSync input status and define local and LightSync switch characteristics select relay s relay groups to be controlled by an input and define how those relay s relay groups are to respond Switch Pilots use this option to program local and LightSync switch pilots Timers use this option to define normal astro and open close timers Then map each timer to the relay s relay group it controls and define its response Set Times use this option to enable dis able daylight savings and define astro clock open close OFF sweep input active parameters There is also a feature allowing you to force a selected timer to execute Presets use this option to capture edit and trigger presets from your PC Add on Module use this option to enter parameters associated with optional DMX DTMF 2 and MODBUS control features Special Functions use this option to customize names of the LightMaster controller relay relay groups inputs and presets You can also change the relay drive parameters and LightSync photoce
15. enu LightMaster Pro User Manual Version 1C 1 1 05 3 13 Getting Started LIGH ster ILC LightMaster Off Hours Sweep Interval File Connect Setup Edit Document About Off Hours Sweep Interval 1 Hour Interval 2Hour Interval File Name None Figure 3 14 Interval Definition Screen Connected ILC LightMaster Off Hours Sweep Relays File Connect Setup Edit Document About JRELAYOT Off RELAYO2 off RELAvo3 off RELAYvo4 off RELAvOs off RELAvoe off RELAYvo7 JRELAYO8 File Name None Connected Figure 3 15 Off Hours Sweeps Relays Screen LightMaster Pro User Manual 3 14 Version 1C 1 1 05 Getting Started HGH 3 4 Save the Settings to a 1 Select FILE from the menu bar 2 Enter a file name 3 Select Save As from the file menu The file will be saved to your hard drive or other media for future use ILC LightMaster Off Hours Sweep Relays EEF Connect Setup Edit Document About New Open Save Exit RELAVOE RELAVOE RELAYOS File Name None Connected Figure 3 16 Pull Down Menu LightMaster Pro User Manual 3 15 Version 1C 1 1 05 Getting Started LIGH rere Master ILC LightMaster Off Hours Sweep Relays File R Save in ILC LightMaster E3 Recent Documents My Network Places Documentation
16. gt Blink Alert And Alarm Settings Configure Timed On Force Timers Sunday Monday Tuesday Wednesday Thursday Friday 4 44444 4 Saturday lt Ignore Holidays Connected Figure 3 8 Timer Pull Down Menus LightMaster Pro User Manual 3 8 Version 1C 1 1 05 Getting Started ILC LightMaster Timer To Relay Control File Connect Setup Edit Document About TIMER 01 None 02 None None REUAYO4 None REUAYOS None REUAYOS None Tum On RELAY 08 File Name None Figure 3 9 Timer to Relay Control Screen LightMaster Pro User Manual Version 1C 1 1 05 LIGH Pro Connected 2 tw Getting Started Enter Astro Clock Settings 1 Select EDIT from the menu bar then select Set Times from the pull down menu 2 Point and click on Astro Clock Settings 3 When the Astro Clock Settings screen appears point and click on the pull down screens and select the proper coordi nates for the location of the LightMaster ILC LightMaster Astro Clock Settings File Connect Setup Edit Document About IGH NOTE You may also click the Find Latitude Longitude by City button scroll and select the proper city if available and the proper coordinates will be entered in the appropriate fields Astro Clock Settings Latitude Longitude 90 Time Zone Cental 7 Find Latitude L
17. htMaster Pro User Manual Version 1C 1 1 05 3 11 Getting Started HGH ILC LightMaster Edit Presets File Connect Setup Edit Document About RELAVOT RELAY02 RELAYOa REUAYOS RELAYS RELAVO RELAYOS File Name None Connected 2 Figure 3 12 Edit Presets Screen LightMaster Pro User Manual 3 12 Version 1 1 1 05 Getting Started Configure Hours OFF Sweeps See Figures 3 13 14 15 1 Select EDIT from the menu bar then select Set Times from the pull down menu 2 Point and click on Off Hours Sweeps 3 Select Interval 4 When the Off Hours Sweep Interval screen appears select the 3 Hour Interval button ILC LightMaster Edit Presets File Connect Setup Document About IGH 5 Repeat steps 1 2 selecting Relays 6 Select Relay 01 then click the action field until OFF appears 7 Repeat step 6 to set actions for Relays 02 06 You have completed entering the settings Relay Outputs RERESET 01 Switch Inputs Switch Pilots RELAYOT 01 Timers b Set Times 4 RELAY 02 Presets RELAY 03 Add On Modules Daylight Saving Time Astro Clock Settings Open And Close Times gt Special Functions 4 RELAY 04 Relays Groups Input Active Times REUAYOS On RELAV0e RELAV08 7 Connected Figure 3 13 Presets Pull Down M
18. ll scan rate with this option LightMaster Pro User Manual Version 1C 1 1 05 LIGH Pro tw Program Description and Installation HGH ILC LightMaster Eile Connect Setup Edit Document About Ctr ILC LightMaster Single Panel Configuration Software Version 6 21 800 922 8004 www ilc usa com Copyright 2003 ILC File Name None Disconnected Figure 1 1 LightMaster Pro Home Screen LightMaster Pro User Manual Version 1C 1 1 05 fer Program Description and Installation LightMaster Pro User Manual Version 1 1 1 05 LIGH Pro fer IGH UGH aster Section 2 Communications ILC LightMaster Connect Eile Connect Setup Edit Document About Line Functions 1 LightM aster Firmware Revision TETrTe S TE TRE T Communications rr rremrmrrmremr zn Time 045527 PM 3 j Date Thu 01 30 03 s Installed O8Inputs Relays Add On Card None Virtual Keypad Disconnect From LightMaster Download Settings To Upload Settings From LightMaster LightMaster File Name None Connected LightMaster Pro User Manual Version 1 1 1 05 Section 2 Communications Pro Section 2 Communications 2 1 Comminication Methods scssi 2 2 2 Communication 5 UC y va REL REFERRI EL PM dT IS cet 2 1 2 3 Sample PrOCSOUNSS 2 3 24 Keypad
19. nctions Timers Relay Grouping EET ETFI RIF IRIS CREN ECEE TET E73 Set Times 3 Switch Pilots Relay Output Options aster Firmware Revision Communications Presets Add On Modules Special Functions gt CUM 04 57 06 PM Ju Set LightMaster Clock C CUM Date Thu 01 30 03 me 1 0 Installed 08 Inputs Relays Add On Card None Virtual Keypad Download Settings To Upload Settings From LightMaster LightM aster File Name None Connected Figure 2 7 Relay Controls Screen ILC LightMaster Relay Status File Connect Setup Edit Document About RELAVO3 RELAYVOE RELAYOS RELAVO RELAYUS All Relays On File Name None Connected Figure 2 8 Relay Status Screen LightMaster Pro User Manual 2 5 Version 1C 1 1 05 Communications HGH ILC LightMaster Connect File Connect Setup Edit Document About On Line Functions dn LightMaster Firmware Revision TETrTe HIT IMfA S TE TRE T T T Communications enanar C COM Time 04 55 27 PM COM Mode Date Thu 01 30 03 1 0 Installed 08 Inputs Relays Add On Card None Virtual Keypad i Disconnect From LightMaster Download Settings Upload Settings From LightMaster LightMaster File Name None
20. ntrol Screen LightMaster Pro User Manual 3 5 Version 1C 1 1 05 Getting Started Define the Timers See Figures 3 6 7 1 Select EDIT from the menu bar then select Timers from the pull down menu 2 Point and click on Configure Timers 3 When the Timer Configuration screen appears select Timer 01 from the pull down menu 4 Point and click on the Astro Time button ILC LightMaster LightSync Input To Relay Control File Connect Setup 2 Document About IGH 5 Point and click on the time pull down screens to select 10 min and Before Sunset 6 If you do not want Timer to execute every day of the week uncheck the appropriate box for that day of the week 7 Repeat steps 3 5 selecting Normal Time where appropriate until all 6 timers have been defined Relay Outputs gt LSYNC 02 Switch Inputs LSYNC 02 6 Switch Pilots RELAY 01 Set Times RELAY 02 Presets Add On Modules Timer To Preset Control RELAY 03 Special Functions gt Blink Alert And Alarm Settings RELAY 04 Configure Timed On RELAYOS No Action Force Timers RELAY 08 On And Of RELAYO7 No Action RELAY 08 No Action File Name None Timer To Relay Control Timer To Group Control ___ NN b Connected Figure 3 6 Timer Pull Down Menus LightMaster Pro User Manual Version 1 1 1 05 Getting Started HGH ILC LightMaster Configure Timers File C
21. o User Manual Version 1C 1 1 05 Getting Started HOM aster ILC LightMaster File Connect Setup 2 2 Document About Relay Outputs Local Inputs 4 Switch Pilots LightSync Status Timers d Configure LightSync Devices Set Times LightSync Input To Relay Control b Presets LightSync Input To Group Control Add On Modules Special Functions ILC LightMaster Single Panel Configuration Software Version 6 21 800 922 8004 www ilc usa com Copyright 2003 ILC File Name None Disconnected Figure 3 2 Switch Input Menu ILC LightMaster Configure LightSync Devices File Connect Setup Edit Document About LSYNC 02 LightSyne Configuration Push Button Input Momentan PB l Momentan Input 2 Momentary PB Input Momentary PB Input 4 Momentary PB Input 5 Momentary PB Input 6 Momentary PB File Name None Connected Figure 3 3 Completed Configuration Screen LightMaster Pro User Manual 3 3 Version 1C 1 1 05 Getting Started Program the LightSync Input Relay Control See Figures 3 4 5 1 Select EDIT from the menu bar then select Switch Inputs from the pull down menu 2 Point and click on LightSync Input to Relay Control 3 When the LightSync Input to Relay Control screen appears select LSYNC 02 from the pull down menu A second pull down menu appears with the sub addresses of the first button LSYNC 02 1 as well as
22. ommands you can quickly and easily program LightMaster light ing controllers for any required application obtain current status and upload down load operating parameters between the con troller and your personal computer You can program a single controller from your RS232 connection to the controller serial port You can also program offsite via standard phone lines and modem Gf the LightMaster is equipped with an onboard modem requires a direct analog telephone line 1 1 Installation This section explaind how to install LightMaster Pro on your computer and outlines what you should and can do after the installation is complete Most customers have LightMaster Pro installed on their com puter at the factory or by an ILC field service technician during the system start up If you have elected to install the software yourself follow these instructions Minimum System Requirements e IBM compatible PC e Pentium 4 1 6GHz or greater 05232 serial port e CD R drive e Windows 2000 XP e 100 MB Free Space 512 MB RAM e SVGA monitor 1024 x 768 recommended e Mouse amp keyboard Performing the Installation NOTE You may need Adrministrator s privi lages to install the software Load the CD disk containing LightMaster Pro into your comput er s CD drive Exit any open applications and temporarily disable virus protection software LightMaster Pro User Manual Version 1C 1 1 05
23. ongitude By City File Name None Connected Figure 3 10 Astro Clock Screen LightMaster Pro User Manual Version 1C 1 1 05 3 10 Getting Started Define Presets See Figures 3 11 12 1 Select EDIT from the menu then select Presets from the pull down menu 2 Point and click on Edit Presets 3 When the Edit Presets screen appears verify that Preset 01 is in the Preset pull down box Select Relay 03 then click the action field until ON appears Select Relay 04 then click the action field until OFF appears ILC LightMaster Timer To Relay Control File Connect Setup 518 Document About 6 N LIGH Pro Select Relay 05 then click the action field until ON appears tw Select Relay 06 then click the action field until OFF appears Select Preset 02 from the Preset pull down box Repeat steps 4 7 entering the proper set tings for Preset 02 NOTE To invoke a Preset connect to the LightMaster point and click on Capture Presets select the desired Preset and click the Set button Relay Outputs Switch Inputs Switch Pilots RELAY 01 Timers Set Times RELAY 02 Add On Modules RELAYO3 Special Functions gt RELAY 04 None RELAYUS None RELAYOS None RELAYO7 None RELAYOS None Capture Presets File Name None Connected Figure 3 11 Presets Pull Down Menu Lig
24. onnect Setup Edit Document About Timer TIMER 01 Time C Normal Time Sunrise Open Close Time Day Normal Days Sunday Holiday Monday Tuesday Wednesday Thursday Friday Saturday Ignore Holidays File Name None Connected E Figure 3 7 Configure Timers Screen LightMaster Pro User Manual 3 7 Version 1C 1 1 05 Getting Started IGH Program the Timer to Relay Control See 4 Point and click on the action pull down Figures 3 8 9 screen for Relay 7 and click Turn On 1 Select EDIT from the menu bar then 5 Point and click on the action pull down select Timers from the pull down menu 2 Point and click on Timer to Relay Control 6 3 When the Timer to Relay Control screen appears select Timer 01 from the pull down menu screen for Relay 8 and click Turn On Repeat steps 3 5 entering the appropri ate timer relay and action settings until Timer to Relay Control is complete for all timers ILC LightMaster Configure Timers Fie Connect Setup 2 Document About Timer 01 Time Normal Time eR pen Close T Day Normal Days Holiday File Name None Relay Outputs gt Switch Inputs Switch Pilots gt Timers gt Configure Timers Timer Relay Control Timer To Group Control Add On Modules Timer To Preset Control Special Functions

Download Pdf Manuals

image

Related Search

Related Contents

Operating Instructions Blu-ray DiscTM Player  Manual de Usuario Traveler para Android  MKE 1  User Manual for Multi Scale Mapping Specifications  LG Electronics LRT 2232 Refrigerator User Manual  Notice d`installation du moteur central de rideau métallique NICE  Philips SWV3135W User's Manual  IMPORTANTE!  SUNNE 32-63-LP flat panel wall mount  

Copyright © All rights reserved.
Failed to retrieve file