10U 4X SDR/DDR InfiniBand Switch Platform User`s Manual
Contents
1. 33 Appendix A Integrated Management Features The default and recommended way to manage the Switch is using the IBADM package as described in Chapter 3 All features described below are also available with the IBADM tools However the Switch may include an integrated management CPU on a Spine board that provides an alternate method of performing some of the management func tions The CPU and dedicated control logic is located on the Spine board for monitoring the chassis hardware environment and hot swap events This CPU is accessible through an RS 232 Serial port or an Ethernet 10 100 interface The fol lowing functionality is provided Familiar Linux OS environment with RS 232 Console Interface and Ethernet Secure Shell Access Note Fabric management is defined in Chapter 14 Subnet Management within the InfiniBand 1 2 Specifi cation The Switch does not include integrated subnet management Thus an external host based Subnet Manager is required to support the required InfiniBand fabric management functions The following section describes how to configure and use the Operating System A 1 Getting Started Switch Integrated Management Figure 1 CPU Status LEDs Fan Status Embedded management is implemented by a processor on one of the Spine boards The Spine with an active CPU can be identified by a lighted CPU Status indicator on the Spine I O panel see Figure 1 This requires special SW support on the managemen
2. Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual Revision History Table 3 Revision History of this User s Manual Revision Date Details 0 60 Oct 2006 No 12X port Leafs are available All 12X relevant text is removed Added Section 2 1 Installation Safety Warnings on page 13 Added a note to Section A 1 Getting Started Switch Integrated Management on page 33 regarding SW support for CPU Status and Ethernet activity LEDs Minor text modifications to enhance clarity throughout the document 0 50 Dec 2005 Added a description of Out of Band Embedded Management Tools as Embedded Man agement Tools on page 32 The tools User s Manual is listed in under About this Man ual on page 9 0 40 Nov 2005 First revision released Rev 0 60 40 Rev 0 60
3. 2 Ethernet Access A 1 3 Verifying Status of Drivers Appendix B Specifications Appendix C Mechanical Drawings Appendix D RS232 Connector Pinout Revision History Sonn w Rev 0 60 4 Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual List of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Switch Hardware Components Two Power Inlets Electric Caution Notification PSU And Alarm Indicators Leaf Status Present PHY and Logical Link LEDs Topology of a 144 4X Port Switch Retaining Screw and Red Button Leaf Board Extraction Spine Board Extraction Spine Board Insertion PSU Extraction PSU Insertion Fan Module Extraction Fan Module Insertion Default Configuration Model CPU Status LEDs Fan Status Status Hot Swap and System Fail LEDs Chassis Side View Drawing Chassis Front View Drawing Chassis Rear View Drawing Integrated CPU Board Ports Diagram 11 16 17 18 19 20 20 22 24 25 26 27 28 31 33 34 37 37 37 38 Rev 0 60 5 6 Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual List of Tables Table 1 Reference Documents and Websites Table 2 Switch Configuration Examples Table 3 Ordering Part Numbers Table 4 Additional Part Numbers Table 5 Switch
4. Rack Mechanical and Environmental Requirements Fully Populated Chassis Table 6 Port LEDs Decoder Table Table 7 Switch Specifications Table 8 RJ45 Pinout Table 9 Revision History of this User s Manual 11 12 12 15 16 36 38 39 T id 10U 4X SDR DDR InfiniBand Switch Platform User s Manual About this Manual This manual provides an overview of the 10U Chassis 4X InfiniBand Switch Platform and guidelines for its opera tion Intended Audience This manual is intended for users and system administrators responsible for installing and setting up the switch plat form The manual assumes familiarity with the InfiniBand architecture specification Related Documentation The documentation set accompanying the 10U 4X InfiniBand Switch platform includes the following Table 1 Reference Documents and Websites Switch Firmware and Firmware Update Tools See http www mellanox com under Firmware downloads Note that the Switch System described in this manual is based on Mellanox Technolo gies MT47396 InfiniScale III switch device InfiniBand Administration IBADM Tools User s Manual Document no 2130UM Mellanox Technologies document Describes the installation and use of IBADM tools for management and firmware updates of platforms based on Mellanox Technologies Infini Band devices Available from http www mellanox com under Management Tools IB Switch Platforms Emb
5. port is established but the logical link connection 1s not ON steady ON Steady Both the physical and logical link connections of port are established Blinking Physical link error ON Steady Blinking mg activity is on going Blinking rate is proportional to traffic OFF OFF Cable is unseated unconnected Note The switch does not provide a visual means that indicates the port speed configuration SDR DDR The speed configuration however can be retrieved using software Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 17 Warning Take care to not impede the air exhaust flow through the ventilation next to the InfiniBand ports Use cable lengths which allow routing horizontally around to the side of the chassis before bend ing upward or downward in the rack 2 2 4 Switch Power Up Check all boards power supply and fan tray modules for proper insertion and seating before turning on the power switch read Section 2 2 6 through Section 2 2 7 to ensure all modules are properly installed Do not leave any open slots in the chassis Insert thermal blanks in unused leaf slots and make sure that both power supply doors are shut in order to maintain balanced air flow Also mounting screws should all be tightened The power switches are located just above the AC inputs as shown in Figure 1 Switch Hardware Components on page 11 2 2 4 1 Power Supply and Spine Board Indicator Status at
6. 10U 4X SDR DDR InfiniBand Switch Platform User s Manual Rev 0 60 2 10U 4X SDR DDR InfiniBand Switch Platform User s Manual Contents Contents List of Figures List of Tables About this Manual Chapter 1 Overview 1 1 Ordering Information 1 1 1 Additional Parts for Standalone Ordering Chapter 2 Switch Installation and Basic Operation 2 1 Installation Safety Warnings 2 2 Installation Steps 2 2 1 Physical Installation 2 2 2 Power Connections 2 2 3 InfiniBand Copper Cable Installation 2 2 4 Switch Power Up 2 2 4 1 Power Supply and Spine Board Indicator Status at Power ON 2 2 5 InfiniBand Fabric Initialization and Management 2 2 6 Hot Swap Extraction Insertion of Leaf Boards 2 2 6 1 Extracting a Leaf Board 2 2 6 2 Inserting a Leaf Board 2 2 7 Hot Swap Extraction Insertion of Spine Boards 2 2 7 1 Extracting a Spine Board 2 2 8 Inserting a Spine Board 2 2 9 Hot Swap Extraction Insertion Power Supply Modules 2 2 9 1 Extracting a PSU 2 2 9 2 Inserting a PSU 2 2 10 Hot Swap Replacement of Fan Module 2 2 10 1 Extracting the Fan Module 2 2 10 2 Inserting the Fan Module 2 2 11 Switch Protection Mechanisms 2 2 11 1 Over temperature Shutdown Mechanism Chapter 3 Switch Management Tools 3 1 IBADM Features 3 1 1 IBADM Reguirements 3 1 2 How to Get IBADM 3 2 Embedded Management Tools Appendix A Integrated Management Features A 1 Getting Started Switch Integrated Management A 1 1 Serial Console Access A 1
7. Power ON As the power is turned on you should observe the following conditions for normal operation 1 Power Supply Unit s AC OK and DC OK indicators are ON and Alarm indicator is OFF See Figure 3 Figure 3 PSU And Alarm Indicators rua 2 All LED indicators on the Spine and Leaf Boards light up briefly and then turn off 3 Spine Board indicators will display status of internal links to the installed Leaf Boards All PHY links to present Leaf Boards should be ON 4 There is a green Status LED that indicates per Spine and per Leaf Board that all its power supplies are good Make sure that all are on See Figure 4 ete Mo te S EEA e ENE 5 There is a yellow Status LED per Leaf and per Spine Board For a Leaf Board it should always be off For a Spine Board it is on in case one of its power supplies are faulty Make sure they are all off iji 6 For Spine Boards only There is a yellow System Fail LED that will light to indicate one of the following failure situations a fan failure over tempera ture or a main AC power supply failure On power on this LED will blink 2 for several seconds and then turn off if none of the above situations has occurred 7 There is a blue LED per Spine and per Leaf Board It should be off for all boards t Rev 0 60 Switch Installation and Basic Operation 18 The Spine Board has two sets ofindicators One shows which Leaf Boards are present The
8. anagement EMC TBD Scalability and Performance Reliability Availability and Serviceability Features Switching Performance Addressing Hot Swappable Simultaneous wire speed any port to any port 48K Unicast Addresses Max per Subnet 16K Multicast Addresses per Subnet 4X Leaf Boards 12 10or 20 Gb s Ports Code Load and Activation Hot Swappable N 1 Redundant Link Failover Fan Module Power Supplies Leaf and Spine Modules Power Supplies and Fans Yes IB Automatic Path Migration 1 The connector is good for 10Gb s operation too Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual Appendix C Mechanical Drawings Figure 3 Chassis Side View Drawing 38 50 Figure 4 Chassis Front View Drawing Rev 0 60 38 Appendix D RS232 Connector Pinout The RS232 monitor connector is a shielded RJ45 Jack where the shield is connected to GND The jack pinout is pro vided in Table 2 In Figure 6 Tntegrated CPU Board Ports Diagram the jack is module instance PM1 Table 2 RJ45 Pinout Pin Number Pin Name 1 NC 2 NC 3 DTR 4 GND 5 RXD 6 TXD 7 CTS 8 RTS Figure 6 Integrated CPU Board Ports Diagram UTILITY DEBUG TAP HEADER PORT PORT vo BUS EXPANSION EXPANSION SERIAL PORT SCC1 2 3 4 4 A N KA ETHERNET MONITOR FAST ETHERNET POWER 5VDC PORT PORT PORT ScC1 SMC1 2 MID 7001408
9. bronche uniquement qu un disconnects only one Einheiten spannungsfrei zu module Alimentation Stabilise e power supply module machen sind die Pour isoler completement le o isolate the unit Netzstecker aller Netzteile module en cause IL faut completely disconnect all zu entfernen de broncher toutes les power supplies alinentations stabilise es 2 2 3 InfiniBand Copper Cable Installation The Switch uses industry standard 4X InfiniBand copper cables which are available from several vendors The stan dard 4X cables support full 20 20Gb s DDR and 10 10Gb s SDR bidirectional wire speed of the Switch ports ALI InfiniBand 4X connections are made to the Leaf Boards Each Leaf has 12 InfiniBand 4X copper connectors which are numbered 1 12 from left to right All cables can be inserted or removed with the unit powered on To insert a cable press the connector onto the port receptacle until the connector is firmly seated The green LED indicator to the left of the port will light when the physical connection is established when unit is powered on Then lock the connector using the latching mechanism particular to the cable vendor To remove disengage the lock and slowly pull the connector away from the port recep tacle Table 6 is a decoder of the ports yellow and green LEDs states Table 6 Port LEDs Decoder Table Port Green LED State Port Yellow LED State Description ON steady OFF Physical link connection of
10. ctions before connecting the equipment to the power source 2 Bodily Injury Due to Weight This equipment is very heavy and should be carried by four people to avoid back and or other bodily injuries 3 Over temperature This equipment should not be operated in an area with an ambient temperature exceeding the maximum recommended 50 C 122 F Moreover to guarantee proper air flow allow at least 8cm 3 inches of clearance around the ventilation openings 4 Stacking the Chassis and equipment damage 5 Redundant Power Supply Connection Electrical Hazard This product includes a redundant power or a blank in its place In case of a blank power supply do not operate the product with the blank cover removed or not securely fastened 6 During Lightning Electrical Hazard During periods of lightning activity do not work on the equipment or connect or disconnect cables The chassis should not be stacked on any other eguipment If the chassis falls it can cause bodily injury Rev 0 60 Switch Installation and Basic Operation 14 gt P P P P P BP 7 Copper InfiniBand Cable Connecting Disconnecting Copper InfiniBand cables are heavy and not flexible as such they should be carefully attached to or detached from the connectors Refer to the cable manufacturer for special warnings instructions 8 Rack Mounting and Servicing When this product is mounted or serviced in a rack special precautions must be tak
11. describes In Band management of the Switch System using the IBADM package Section 3 1 Out of Band management of the Switch System via Embedded Management Tools Section 3 2 3 1 IBADM Features Maintenance and configuration of the Switch is done in band through the InfiniBand fabric using the Mellanox InfiniBand Administration IBADM tools package see Related Documentation on page 9 This package provides the ability to make firmware upgrades and monitor the temperature voltage port utilization and other status parame ters in the switch The IBADM tools enable the system administrator to manage one or more Switches from a single remote InfiniBand host The features include the following Full In Band Management of multiple Switch Systems and Mellanox HCA Systems from a single host Simple default configuration to get started quickly Name based subnet browsing and topology verification Event monitoring of port statistics link status and system status for all ports in the switch Checking and updating the firmware Intuitive Command Line Interfaces Extensible and customizable via common scripting languages Note IBADM provides no baseboard management capabilities Figure 14 shows the default configuration model for these tools Figure 14 Default Configuration Model Switch Administration Components HCA Switch System Driver IBADM Tools InfiniBand HCA PRITI Rev 0 60 Switch Management Tool
12. edded Management Tools Document no 2141UM Describes the Embedded Management Tools EMGT package which pro vides Out of Band management capabilities for InfiniBand switches Available from http docs mellanox com requires a Mellanox Technolo gies customer account Rev 0 60 10 Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 11 1 Overview This User s Manual provides an overview of the 10U 4X SDR DDR Modular InfiniBand Switch Platform the Switch and the operational environment The document is organized into the following sections e Switch Installation and Basic Operation page 13 e Switch Protection Mechanisms page 28 The Switch ships in a minimum base configuration plus additional modules depending on the chosen customer con figuration Optional modules include Leaf boards a redundant management capability of Spine boards and redun dant power supply units Figure 1 Switch Hardware Components shows the various hardware components required for installation Table 2 provides some configuration examples Figure 1 Switch Hardware Components Hot Swap Spine Boards With Management Interfaces 1 left and 2 right Dual AC Imput and ON OFF Switch Hot Swap Power Supply Unit 1 left amp Unit 2 right Hot Swap Fan Module Air Intake Air Exhaust Mounting Rails Rack Front Mounting Shown Table 2 Switch Co
13. en to ensure that the system remains stable In general you should fill the rack with equipment starting from the bottom to the top 9 Equipment Installation This equipment should be installed replaced or serviced only by trained and qualified personnel 10 Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regulations 11 Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical codes 12 Norway Electrical Codes Electrical Hazard The switch platform must be connected to an earthed mains socket outlet 13 Norway Electrical Codes Electrical Hazard In Norway this system should be connected to the IT power distribution system only Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 15 2 2 Installation Steps Installation and initialization of the Switch is a simple process requiring attention to the normal mechanical power and thermal precautions for rack mounted equipment The Switch does not require any programming or configura tion to begin operation in an InfiniBand fabric using standard compliant Subnet Management software The following steps provide a basic overview of the installation process Physical Installation Section 2 2 1 Power Connections Section 2 2 2 InfiniBand Copper Cable Installation Section 2 2 3 Switch Power Up Section 2 2 4 InfiniBand Fabric Init
14. her grasping its middle as in Figure 9 c 2 Insert the board into its rail The board should slide in without resistance 3 Once the board is about 4 inches 10cm inside its rail hold the spine ejectors and push the board in until it can not move 4 Make sure the spine ejectors are open all the way 90 degrees Now press both ejectors inward simultaneously You should feel the ejectors are hooked into the front panel See Figure 9 a 5 With the guide pin at top of the board from inside aligned with its hole in the system panel press both ejectors applying some force to close them completely The ejectors have small security pins that should fit into the small slots in the Spine board panel See Figure 9 b Note Some switch versions have a captive screws instead of a security pin 6 Screw in the captive retaining screws to the left of each ejector to lock the Spine board in place Rev 0 60 Switeh Installation and Basic Operation 24 Figure 9 Spine Board Insertion Guide Pin Ejector Hook Security Pin Slot for Securing Spine Ejector a Guide Pin b Securing the Spine board 2 2 9 Hot Swap Extraction Insertion Power Supply Modules A PSU Power Supply Unit in a redundant configuration can be extracted without bringing down the system A sin gle PSU should not be extracted with the system on if the system is not in redundant configuration Please refer to Figure 1 Switch Hardware Compone
15. ialization and Management Section 2 2 5 Hot Swap Extraction Insertion of Leaf and Spine Boards Section 2 2 6 Hot Swap Extraction Insertion of Power Modules Section 2 2 9 60 1 9 Moog SS e Hot Swap Extraction Insertion of Fan Module Section 2 2 10 2 2 1 Physical Installation Warning This eguipment is very heavy and should be carried by four people to avoid back and or other bodily injuries The Switch uses 10U of rackspace in a standard 19 rack As shown in Figure 1 Switch Hardware Components the Switch ships from the factory with the mounting racks on the front side In addition to the mounting rails the Switch reguires support underneath the unit to support the un mounted side in this case the rear side Please ensure to choose a rack which is able to support the mechanical and environmental characteristics of a fully populated Switch Chassis as listed in Table 5 Switch Rack Mechanical and Environmental Reguirements Fully Populated Chassis Table 5 Switch Rack Mechanical and Environmental Reguirements Fully Populated Chassis Rack Rack Height Rack Width an Weight Max Power 144 4X Ports Ambient Temp 10U 19 EIA 310 23 6 159 Ib TBD W 220VAC Max 55 C 600mm 72 2 kg Dual 100 240VAC Inputs 50 Min 0 C 60Hz 14 5 5 8A The rack mounting holes conform to the IEA 310 standard for 19 inch racks Take precautions to guar antee proper ventilation to e
16. il for support See Figure 11 a 6 Close the PSU panel door and tighten the retaining screw 7 Connect the AC cord 8 Turn the AC switch back on The green AC OK and DC OK LEDs should turn on Rev 0 60 Switeh Installation and Basic Operation 26 Figure 11 PSU Insertion a With the lever open push the PSU till it b Press the lever in to lock it Step 5 seats completely Step 4 2 2 10 Hot Swap Replacement of Fan Module The fan module of the Switch platform is located in the center of the front panel see Figure 12 a It includes three fans The system is designed to shut down in the following two fan related cases Failure of two out of the three fans for more than 3 minutes No fan module is in the system for more than 3 minutes Note The yellow Fan Fail LED will blink the moment one fan fails This is a warning that the fan module should be replaced soon 2 2 10 1 Extracting the Fan Module 1 Unscrew the four captive screws that hold the fan module to the chassis See Figure 12 a 2 Slowly slide out the fan module while holding both its upper and lower ejectors 3 Notice that a yellow Fan Fail LED located on the Spine Board is now blinking See Figure 12 b Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual Figure 12 Fan Module Extraction Yellow Fan Fail LED Upper Ejector Fan Module Boundaries Retaining Screws HE a Fan module boundarie
17. lace 2 2 7 Hot Swap Extraction Insertion of Spine Boards Each Switch Spine board has a pair of ejectors that lock the board in place and serve as a lever for seating or extract ing see Figure 8 a 2 2 7 1 Extracting a Spine Board 1 Disconnect all cables connected to the spine 2 Unscrew both top and bottom retaining screws of the spine See Figure 8 a 3 Hold the spine ejectors and press both of them outward simultaneously Expect some resistance before the board pops out See Figure 8 a 4 Pull the ejectors out till they form 90 degrees with the panel of the system Then slide the Spine board about 4 inches 10cm out by slowly pulling the ejectors See Figure 8 b 5 Hold the board with one hand supporting its bottom and the other grasping its middle see Figure 8 c Then slide the board all the way out Note not to damage the GBX connectors on the board and or the EMI gasket of the spine hole in the system Rev 0 60 Switeh Installation and Basic Operation 22 Retaining Spine Ejector a Step 3 of Spine Extraction Figure 8 Spine Board Extraction b Step 4 of Spine Extraction c Step 5 of Spine Extraction Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 23 2 2 8 Inserting a Spine Board Note Do not insert a Spine board before Leaf boards are inserted This may damage the chassis 1 Hold the Spine board with one hand supporting its bottom and the ot
18. nd services for the Switch applications The tool kit is stored in the flash file system at usr mellanox The following shows how to check the status of the driver and application services and the correct responses bash 2 05 mst status MST modules MST PCI module is not loaded MST PCI configuration module is not loaded MST Calibre I2C module is not loaded MST 8xx module loaded MST devices dev mst mif i2c 8xx MPC860 Motorola I2C master The root filesystem is configured as a ram disk which means any changes made to the user environment will not per sist across a reboot or power cycle Rev 0 60 36 Appendix B Specifications Table 1 Switch Specifications Supports SystemImage GUID Physical Power and Environmental Size 17 5 10U H x 23 6 D x 19 W Voltage 100 240VAC 50 60Hz 14 5 5 8A Weight 159 Ib 72 2 Kg fully configured Maximum Power TBD W 220VAC Mounting 19 Rackmount Temperature 0 to 55 Celsius Air Flow 600CFM 200CFM each fan Humidity 10 90 non condensing Heat Dissipation 1000W Altitude 20Gb s Connector InfiniBand Shock Vibration Internal Voltage 48VDC Protocol Support Regulatory InfiniBand Auto Negotiation 20 4X DDR 10 4X Safety TBD SDR 5 1X DDR 2 5 1X SDR QoS 8 InfiniBand Virtual Lanes for all ports RDMA Support Yes All Ports Management Baseboard Performance and Device man agement Agents for full InfiniBand In Band M
19. nfiguration Examples k Leaf Power Supply Spine Board Spine Board Configuration Boards Modules w o Mgmt w Mgmt 12 4X ports 1 Leaf 1 Power Supply 2 Spine boards without management 1 1 2 0 12 4X ports 1 Leaf 1 Power Supply 1 Spine board w o management 1 Spine 1 1 1 1 board with management 144 4X ports 12 Leafs 1 Power Supply 1 Spine board w o management 1 Spine 12 1 1 1 board with management 144 4X ports 12 Leafs 2 Power Supplies 1 Spine board w o management 1 Spine 12 2 1 1 board with management 144 4X ports 12 Leafs 2 Power Supplies 2 Spine boards with management H 12 2 0 2 1 This is the minimal configuration 2 This is the maximal configuration 1 4X IB SDR ports transfer data at 10Gb s and 4X IB DDR ports transfer data at 20Gb s Rev 0 60 12 Overview 1 1 Ordering Information Table 3 on page 12 provides an information guide for ordering a specific configuration of the Switch platform Table 3 Ordering Part Numbers Switch Part Number Description TBD TBD 1 1 1 Additional Parts for Standalone Ordering Table 4 Additional Part Numbers Part Number Part Name TBD TBD Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 13 2 Switch Installation and Basic Operation 2 1 Installation Safety Warnings 1 Installation Instructions Read all installation instru
20. nsure air intake at the front of the chassis and exhaust in the rear this is cru cial for maintaining good airflow at ambient temperature In particular route cables such that they do not impede the air exhaust from the chassis 2 2 2 Power Connections The Switch includes an integrated hot swap power supply which supports up to two load sharing 1000W supply units The slots for the two power supply units PSUs are on the front panel and labelled as 1 2 Two independent AC inputs are located above the slots one for each PSU This dual AC design enables optional use of separate main and backup AC feeds The input voltage is auto adjusting for 110 220 VAC 50hz or 60hz power connections The power cords should be standard 3 wire AC power cords including a safety ground Rev 0 60 Switch Installation and Basic Operation 16 Install at least one power unit to turn on the Switch A single PSU can supply power for all configurations including the maximum populated system The second PSU provides a failover mechanism such that the system will continue operating when one PSU fails Figure 2 Two Power Inlets Electric Caution Notification CAUTION ACHTUNG ATTENTION Risk of electric shock Gafahr des elektrischen Risque de choc et de danger and energy hazard Schocks Entfernen des e lectriques Le de branchement Disconnecting one Netzsteckers eines Netzteils d une seule alimentation stobilise e power suppl spannungsfrei Um olle ne de
21. nts for location of the PSU components 2 2 9 1 Extracting a PSU 1 2 3 4 m Turn off the AC switch see Figure 10 a Note that the yellow System Fail LED turns on see Figure 10 b Disconnect the AC cord Open the PSU panel door by loosening the retaining screw Press the sguare locking button in the lower left corner of the PSU The lever on the lower side should pop out See Figure 10 c Pull the lever outward to the right till the PSU unseats The yellow System Fail LED should turn off Remove the PSU with one hand pulling the lever and the other supporting the PSU from the bottom see Figure 10 d Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 25 Figure 10 PSU Extraction 4C Switch AC Inlet Retaining Screw PSU Panel Door a AC Switch Inlet Door Square Locking Button PSU Lever zj S c Press square button to pop out lever Step 4 2 2 9 2 Inserting a PSU 1 Make sure the AC switch is turned off System Fail LED Il SIsseud p i b Yellow System Fail LED location d Pulling out the PSU Step 6 Insert by sliding the PSU into the opening until slight resistance is felt With the lever opened all the way push 2 Disconnect the AC cord 3 Make sure the lever is unlocked 4 the PSU in until it seats completely See Figure 11 a 5 Press the lever in until it locks Hold the nearby mounting ra
22. s 32 3 1 1 IBADM Requirements The general requirements for installing the IBADM software are listed below Please see the IBADM release notes for details on platform OS Driver and Subnet Management support 1 Computer Platform with any Mellanox Technologies InfiniHost M HCA installed 2 HCA Driver 3 InfiniBand compliant Subnet Management The Open source Subnet Manager OpenSM is recommended 3 1 2 How to Get IBADM The IBADM tool and documentation are available for download via http www mellanox com See Related Docu mentation on page 9 3 2 Embedded Management Tools Embedded Management Tools are based on the I2C interface of the switch system These tools can be run from the embedded Power PC CPU card installed in the switch or from the Linux host PC via a USB to I2C adapter an MTUSB x device available from Mellanox These tools enable basic chassis management functions such as monitoring temperature voltages power supplies and fans Querying for board serial numbers and their revisions In addition the tools enable firmware management capabilities such as Querying for existing firmware versions Burning new firmware from scratch or for recovery from damaged firmware Querying for and changing system GUIDs Checking for duplicate or bad GUIDs For further details see Embedded Management Tools User s Manual Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual
23. s 2 2 10 2 Inserting the Fan Module Ethernet RS 232 faa b Fan Status LEDs You now have up to 3 minutes to insert a new fan module otherwise the system will shut down 1 Slowly slide in the new fan module while holding both its upper and lower ejectors Make sure the guide pin at top of the module from inside is aligned with its hole before pushing the module all the way in See Figure 13 b 2 Screw back the four captive screws 3 Make sure that the ye ow Fan Fail LED is turned off and the green Fan Good LED is on See Figure 12 b Figure 13 a shows the three fans in the extracted module and the opening in the MTS1400 platforms where it should fit Rev 0 60 Switch Installation and Basic Operation 28 Figure 13 Fan Module Insertion Guide Hole Guide Pin b Make sure Guide Pin is aligned with its hole when pushing a Fan module includes three fans 2 2 11 Switch Protection Mechanisms The Switch design includes protective mechanisms which shutdown the switch system upon detecting one of the fol lowing critical conditions 1 Fan related conditions A failure of two out of the three fans for more than 3 minutes or the lack of a fan module in the system for more than 3 minutes causes a shutdown of the switch system See Section 2 2 10 for more details 2 Over temperature condition The Switch0 monitors the temperature on the Spine cards of the system If the tem perat
24. second set shows the internal link status to the Leaf Boards The green PHYSICAL LINK LED indicators on the Spine and Leaf Boards will indicate the state representing the Jg PHY Green LEDs Figure 4 Leaf Status Present PHY and Logical Link LEDs link status of their corresponding ports The green PHY LED is steady ON to indicate the physical link is up It blinks to indicate a physical link error The yellow LOGICAL LINK LED indicates the logical link is Logical Yellow LEDs Leaf Present voococececece OCOT active and will turn ON only when the link is enabled O0O0O00O0000200 C0OdO0O00O00O0000 by subnet management software in the InfiniBand sub net It blinks during activities and the blinking rate is ee I TESH proportional to traffic rate nalo Wia SEE TEK 0 A 8 4 2 2 2 5 InfiniBand Fabric Initialization and Management Subnet Management and Subnet Administration are standard components defined by the InfiniBand Specification which implement fabric initialization discovery and configuration The Switch switching fabric can be managed by any third party Subnet Management software running on an InfiniBand Host that is connected to any Switch port The Switch is also compatible with the Open Source Subnet Manager OpenSM The Switch is basically an InfiniBand fabric built out of individual InfiniBand switch devices and appears so to exter nal Subnet Managers The Switch supports the Systemlmage GUID feat
25. t board please contact Mellanox Technologies The I O panel also has a serial RS 232 console port or Ethernet 10 100 port to access the CPU The processor runs a Linux Operating System tuned for embedded operation and provides a standard envi ronment for remote access After a correct power up sequence both Spine Boards should have the Status LED ON and Hot Swap and System Fail LEDs OFF and at least one spine has the CPU STATUS on See Figure 2 Ethernet RS 232 gt prm S Note The CPU Status LEDs and the Ethernet activity LEDs reguire CPU SW support Mellanox Technologies does not include such support in the supplied management utilities pack age Rev 0 60 34 Figure 2 Status Hot Swap and System Fail LEDs p lt ne vS zl MJIOMJON zl SISSBUD The Switch operating system has the following features 1 64MBytes of System Memory 2 16MB Flash File system including basic Linux tools and secure shell remote access 3 Pre installed Switch tool kit for hot swap management firmware management and monitoring The Linux kernel will boot automatically when the Switch is powered on To reboot the OS use the reboot command at the OS prompt Boot time is approximately 40 seconds All necessary drivers and services for Switch applications are automatically started at boot time A 1 1 Serial Console Access The serial port provides a standard console login to the embedded OS It is accessible
26. the lock and electrically notify the system that an extraction has been reguested 2 2 6 1 Extracting a Leaf Board 1 Disconnect all cables connected to the Leaf board Rev 0 60 Switch Installation and Basic Operation 20 2 Unscrew the retaining screws on the outside of the connectors These Figure 6 Retaining Screw and Red Button screws are captive and will remain hanging in place See Figure 6 3 Press the red buttons to unlock the ejectors 4 Press the ejectors outward so that the board pops out then slowly slide the board out Note that the board is short therefore do not let go of it while sliding it out See Figure 7 Figure 7 Leaf Board Extraction Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 21 2 2 6 2 Inserting a Leaf Board 1 Verify the ejectors are unlocked by pressing the red buttons and pulling the ejectors outward on both sides of the board slot 2 Carefully seat the Leaf board into the side guide rails and slowly slide the board into the chassis until the ejectors begin to engage on the chassis edge 3 Begin pressing the ejectors inward to fully seat the connectors If unusual resistance is experienced pull the board out and inspect for bent pins or connector problems Otherwise continue to seat the board with the ejectors until the locks snap 4 Screw in the captive retaining screws on the outside of each ejector to lock the Leaf board in p
27. through the RJ45 connector on the Spine Board Panel see RS232 Connector Pinout on page 38 A standard DB9 to RJ45 serial cable or equiva lent can be used to connect from a standard PC serial port The Switch is shipped with the following default login parameters Serial Port Configuration 9600 Baud rate 8bits No Parity 1 Stop bit Username root Password 1234 Once logged in a standard Linux command line is available A 1 2 Ethernet Access Access is also provided through the 10 100 Ethernet Port By default the interface is configured to use DHCP to automatically assign an IP address and other network parameters If you choose to statically configure the Ethernet interface you must log in through the serial console and edit the etc sysconfig file to your preferred IP ADDRESS and NETMASK follows bash 2 05 vi etc sysconfig network NETWORKING yes DEVICE eth0 Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual BOOTPROTO none HOSTNAME gz1 IPADDR lt Your chosen IP ADDRESS gt NETMASK lt Your chosen NETMASK gt GATEWAY NETWORK BROADCAST Once the ethernet interface is working remote login is provided via secure shell as shown in the following example Remote Host Prompt ssh lt Your Switch IP Address gt username root password 1234 bash 2 05 A 1 3 Verifying Status of Drivers The OS booting seguence will also automatically start the necessary drivers a
28. ure exceeds a certain threshold a thermal shutdown occurs See Section 2 2 11 1 for details 2 2 11 1 Over temperature Shutdown Mechanism The Switch system uses an on board thermal sensor to track the Spine cards temperature If a card s temperature exceeds an over temperature protection threshold a thermal shutdown occurs Over temperature threshold The over temperature threshold per card is set to 70 C This temperature is reached for example at 57 C ambient temperature with a single fan working Shutdown process 1 The System Fail LED starts to blink 2 After 3 minutes the system shuts down Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual All Leaf cards power Main Spine cards power rails Fans power 3 The System Fail LED stops blinking and remains constantly on Note The only power active after the shutdown is the 5V Auxiliary power of the Spine cards Recovery process If the temperature goes below the threshold within 3 minutes of shutdown initiation the system aborts the shutdown process and returns to normal operation After 3 minutes the power sources listed above are powered down To restart the system s operation the main AC switch must be turned off then on again Rev 0 60 Switch Installation and Basic Operation 30 Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual 31 3 Switch Management Tools This chapter
29. ure of the InfiniBand specification which means that software management tools that support this feature can recognize all the internal devices as a single Switch system Figure 5 shows the topology of a fully populated all 4X ports System 144 ports The system features up to 2 88 Tbit sec IB ports in DDR configuration Constant Bisectional Bandwidth CBB Fat Tree topology that the Subnet Manager will discover and configure to enable a full cluster to operate For more information refer to the documenta tion of the Subnet Manager being used 1 1 44 Tbit sec when IB ports are in SDR configuration Rev 0 60 10U 4X SDR DDR InfiniBand Switch Platform User s Manual Figure 5 Topology of a 144 4X Port Switch 2 NA Ny WC SN zn DIE AVIN BERE im AYE teas SNE ANE E i ZMA KA AAA SEINE ENS E J AWS AWS E MEDIA VENI VE TI AAAA A 6 Leaf B 6 Leaf Boards IME SANS af Boarc 1 Leaf5 AM AA spine TA MAS eafl0E i NIS NE i WWA WIE E z zy f WH ENE kl zj AE EX NE ni i A AR AIN AWS il AU WT AX WE PETI MA X MES E pean ie Norme JANE eaf12 Spine Board 2 2 2 6 Hot Swap Extraction Insertion of Leaf Boards Switch Leafs are located on the back of the system Each Switch Leaf board has a pair of ejectors that lock the board in place and serve as a lever for seating or extracting see Figure 7 The ejectors snap inward to lock the board into place and include a red button to disengage