Home

- Controllux

image

Contents

1. buttoms on the control board PAn a coarse pan movement F PAn a fine pan movement SPEd a pan speed Func pan functions 8 6 Test sequences Use this menu to to run a special demo test sequences without an external controller which will show you some possibilities of using StageBanner 10 AT 8 7 Stand alone setting Use this menu to set options for stand alone mode as a selection of the playing program programming and modifying current programs Audi Music trigger Select this function to enable the sound control of the running programs via the built in microphone Auto Presetting playback This function allows you to select the program which will be played in the stand alone mode after switching the fixture on Selected program will be played continuously in a loop d Abl The option disables Auto function tESt The option will start built in test program PrG 1 The option will start created program No 1 PrG 2 The option will start created program No 2 16 PrG 3 The option will start created program No 3 Note lf the fixture operates in the controller mode DMX controller is connected and any program from this menu is selected in this case the fixture will not respond to the DMX controller after switching on and will play selected program PLAY Playing program Select this menu to run a bilt in program or the 3 freely programmable programs in a loop tESt The option starts built in test progr
2. ENTER 8 1 Fixture Address Use this menu to set the DMX address of the fixture or set the fixture as a Master Slave dM Ad DMX addressing Select this submenu to set DMX start address MA SL Master slave addressing Select this submenu to set the fixture as a Master or Slave Slave1 Slave 9 Option d AbL deactivates master slave setting 8 2 Slave control This function allows you to control the slaves from the master s control panel in a master slave operation Select this function from the main menu and press ENTER Browse the list of all connected slaves SL C 1 SL C 9 by pressing UP or DOWN Select the desired slave and press ENTER button The matching slave control panel is available from the master control panel Note This function is available from the master fixture only 8 3 Fixture informations Use this menu to read an useful information about the fixture Po ti Power on time Select this submenu to read the number of operation hours totL The function shows the total number of the operation hours since the StageBanner 10 AT has been fabricated rSEt The function shows the number of the operation hours that the StageBanner 10 AT has been powered on since the counter was last reset ln order to reset this counter to O you have to hold UP and DOWN and press the ENTER tEMP Fixture temperatures Select this submenu to read the fixture temperatures C Please note that the outside temper
3. If the device shall be lowered from the ceiling or high joists professional trussing systems have to be used The device must never be fixed swinging freely in the room Caution Devices may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the device Before rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight CAUTION Provide a minimum clearance of 0 1meters around air vents CAUTION Use 2 appropriate clamps to rig the device on the truss Maximum load of the fixative plate is 10 kg Make sure that the device is fixed properly Ensure that the structure truss to which you are attaching the fixtures is secure The weight of the load has to be spreaded symmetrically round the rotating axis The device can be placed only in 2 positions horizontally on a plain surface or upside down on a truss For overhead use always install a safety rope that can hold at least 10 times the weight of the device You must only use safety ropes with screw on carabines Pull the safety rope through the two apertures on the bottom of the base and over the trussing system etc Insert the end in the carabine and tighten the fixation screw 7 Possible Installation Banner Mounting clamp Mounting clamp Safety cable always pull it
4. If the master fixture runs a reset all slaves will execute these acts too The master fixture starts simultaneous program start in the other slave fixtures All fixtures have a definite syn chronized starting point when playing back their programs The number of running program is the same in all slaves and depends on the master s choice menu St AL Every fixture runs its program repeatedly starting the program step No 1 when requested by the master For example If the slave fixture has a shorter program length it will continously repeat its program until the master fixture finishes its own program and restarts its program running slave 1 prog step 3 will not be finished If the slave fixture has a longer program length it will restart at prog step 1 before it completes all its prog steps slave 2 prog step 5 will not be played see the picture bellow Restart Starting point Master Prog step 1 Prog step 2 JProg step 3 Prog step A Prog step 5 Program length Continous repeating s Prog step 1 Slave 1 Sete sec es zz Slave 2 Prog step 1 Prog step 2 Prog step 3 Program length Time gt Note Disconect the fixtures from the DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly 11 7 Control menu map Default settings Bold print dM Ad 001 512 MA SL d AbL MASt SLA 1 S
5. LA 9 Po ti rSEt HEMP Cur t Hi tE rSEt DM In PAn 0 255 F PAn 0 255 2 SPEd 0 255 Func 0 255 VErs IC1 b WH ICH D L ICH r PAn On Off dISP turn On Off L d On On Off J d lnt 20 100 FEEd On Off MI SE 1 10 20 FAn S Auto HIGH PA Mo SP Mo ti Mo PAn 0 255 Func 0 255 Stor Pan Pan 1 Pan3 SPEd SPd 1 SPd 5 Func Fun 1 Fun 3 Pan 0 255 F PAn 0 255 SPEd 0 255 Func 0 255 lt D gt S d gt o g EJ e O m 12 tESt St AL IESE EB Audi On Off Auto PLAY Edit SPEC J 1 CodE uPd M No Yes Off tESt PrG 1 PrG 2 PrG 3 tESt PrG 1 PrG 2 PrG 3 PrG 1 PrG 2 PrG t 01 St 99 13 Pan 0 255 S tim 0 1 25 5 s COPY 8 Control menu The control panel situated on the front panel of the base offers several features You can simply set the DMX address read the number of unit hours run test make a reset and also use many functions for setting fixture behaviour Control elements on the control board MODE button leaves menu without saving changes ENTER button enters menu confirms adjusted values and leaves menu UP button and DOWN button moves between menu items on the the same level sets values After switching the fixture on the display shows the initial screen Use UP DOWN to browse through the menu To select a function or submenu press
6. ROBE Banner IO m A series Version 1 3 USER MAN UAL ROBE Lighting s r o e Czech republic e www robe cz StageBanner 10 AT Table of contents 1 Safety instructions 3 2 Operating determinations nnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nenne nnennnnnnnn 4 3 Description OF th device ne a 5 VS Ce AU OW EE 6 4 1 Connection to the Mains EE 6 4 2 Changing the power supply settings EE 6 4 3 RUGS iNe UU Seat eee tech ta RC Eruan Nadal eee an ok 7 4 4 DMX 512 connection connection between fixtures sssssssssssserrerererrrtrrrnnnnnennn 9 5 StageBanner 10 AT DMX Protocol version 1 0 nensssssssaaneeeenansanena 10 CR a te nt 11 5 Kee geleet 11 6 2 Stand alone Ne EE 11 K ee at Map POZO EEN 12 8 Control MEU une 14 8 1 Fixture Address aoi o OE anna anna anna nenn ah rennt 14 2 SINSCONMA ea x drs ius eet daten EA EHER AAA OWE eher 14 8 3 FRiurEIOMMALIOM S au nennen ieh 14 SA P ErSonalty een er ene eT mene mene AEO A emer een restr ELE 15 85 Manual mode sen anne eher 16 EECH 16 8 7 Stand alone setting nassen ira ent 16 8 8 Reset function SSR ESCHER tsk ect NEE pu ta ake SEES AO ATE 17 8 9 Special functions aaa A AE OO GAAS an aan AA AW OE AE aan dnia KA 17 9 LOW power OGG wawer aa a eaaa wdowi jwn 18 10 Error and information messages ccccceeseseeeessnnnnnnnnnnececeneeeeeeeeeeeeeeeeeeesenseeesesnnnenen 19 11 Technlcalspecifleatl ns
7. am PrG 1 The option starts created program No 1 PrG 2 The option starts created program No 2 PrG 3 The option starts created program No 3 Select the program you wish and press ENTER The selected program starts running By pressing ENTER is possible to pause the program running Edit Editing program Select this menu to edit or create the program The StageBanner 10 AT has one built in program test and the 3 free programs each up to 99 steps Each program step has a step time Step time the time during which effects last in the current step If the fixture is set as a master then you may edit any program in the slaves You can t edit programs on the slave fixtures from their control panels if the master fixture is switched on and connected to the slaves editing is possible from the master control panel only Procedure 1 Press UP or DOWN to select the program you want to edit PrG 1 PrG 3 and press ENTER 2 Press UP or DOWN to select the desired fixture MASt SLA 9 and press ENTER button 3 Press UP or DOWN to select the desired program step St 01 St 99 and press ENTER button 4 Press UP or DOWN to select the desired item and press ENTER button Now you can edit by UP or DOWN buttons the DMX value 0 255 for selected item P End a total number of the program steps value 1 99 This value you must set before start programming e g if you want to create program with the 10 st
8. as to be accessable after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord This device falls under protection class Therefore it is essential to connect the yellow green conductor to earth The electric connection repairs and servicing must be carried out by a qualified employee Do not connect this device to a dimmer pack During the initial start up some smell may arise This is a normal process and does not necessarily mean that the device is defective 2 Operating determinations This device was designed for indoor use only If the device has been exposed to drastic temperature uctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Do not shake the device Avoid brute force when installing or operating the device Always hold the device at the transport handles When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others Make sure that the area below the insta
9. ature should not exceed 45 C 14 Cur t Current fixture temperature Current temperature on the main board in the base of the fixture If temperature exceeds 87 C the fixture will go to the Power down mode Hi tE Maximum fixture temperature The function shows the max temperature on the main board since the StageBanner 10 AT has been fabricated HEAd The function shows the max temperature of the head inside since the StageBanner 10 AT has been fabricated rSEt Maximum resetable temperature The function shows the maximum temperature on the main board since the counter was last reset ln order to reset the counter to 0 you have to hold UP and DOWN and press the ENTER DM In Readout of DMX values Select this function to read DMX values 0 255 of each channel received by the fixture PAn a coarse pan movement F PAn a fine pan movement SPEd a pan speed Func pan functions VErS Software version Select this function to read the software version of processors IC1 b Main processor on the main board in the fixture base IC2 b Pan processor on the main board in the fixture base IC3 b EEprom on the main board in the fixture base 8 4 Personality Use this menu to to modify the StageBanner 10 AT operating behavior r PAn Pan reverse Select this function to invert the pan movement DiSP Display adjusting This function allows you to change the display settings turn Select this func
10. efore applying power If you wish to change the power supply settings see the chapter below Connect the fixture to the mains with the power cord If the plug onthe exible cord is not the right type for your socket outlets do not use an adaptor but remove the plug from the cord and discard Carefully prepare the end of the the supply cord and fit a suitable plug The earth has to be connected The occupation of the connection cables is as follows Gabi Eu cabio us Pin International L Brown Live Light blue Neutral Yellow Green Earth 4 2 Changing the power supply settings Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency The wrong settings can cause poor performance or demage of the fixture The factory settings are printed next to the power switch If you want to change the power supply settings follow the instructions 1 Disconnect the fixture from AC power 2 Remove the top base covers by loosening the 10 fastening screws 3 Move the wire O on the transformer connection block to the position according to the desired voltage 4 Close the base before applying AC power Examples EU version US version 0303834 2 2 O AC 230V 50Hz AC120V 60Hz 4 3 Rigging the fixture DANGER TO LIFE Please consider the respective national norms during the installation The installation must only be carried out by an author
11. emo sequences Silent cooling Master slave operation Digital serial input DMX 512 4 control channels Pan 16 bit movement resolution continuous pan rotation Automatic pan position correction Remotely controllable speed of pan movement for easy programming Movement control tracking and vector Rigging Stands directly on the oor Mounts horizontally with 2 Omega brackets Safety chain cord attachment point Max load 10 kg Max ambient temperature 45 C 19 Dimensions mm Je 6 o QI EJ Weight net 12 kg Accessories Omega holder No 99010420 4 pcs 12 Maintenance and cleaning It is absolutely essential that the fixture is kept clean Dust must be cleaned from the fan and air vents periodically The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet DANGER Disconnect from the mains before starting any maintenance work More complicated maintenance and service operations are only to be carried out by authorized distributors Replacing the fuse Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure 1 Unscrew the fuseholder on the rear panel of the base with a fitting screwdriver from the housing anti clockwise Remove the old fuse from the fuseholder Install the new fuse in the fusehold
12. eps set P End 10 PAn a coarse pan movement SpEd a pan speed Func pan functions S tim a step time value 0 1 25 5 seconds COPY copying the current prog step to the next prog step If the last prog step is copied to the next prog step parameter P End is increased about one automatically except step 99 5 Press ENTER button to confirm adjusted value 6 Press MODE button select next prog step and repeat this procedure steps 4 6 8 8 Reset function This option enables the StageBanner 10 AT to index all effects functions and return to their standard posi tions 8 9 Special functions Use this menu for special services CodE Code This function contains identification hexadecimal code 0000 FFFF for the fixture which is used for the master slave operation uPd M Updating mode Using this function you can update software in the fixture via PC and serial link The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 17 Note1 Software update should execute a qualified Gerson IW you lack qualification do not attempt the update yourself and ask for help your ROBE distributor Note 2 DMX address IP address programs 1 3 and all functions in menu PErS will be set to their default values To update software in the fixture 1 Installation of DMX Software Uploader 1 DMX Software Uploader prog
13. er 2 3 4 Replace the fuseholder in the housing and fix it Specifications are subject to change without notice 20 21
14. g menu A001 After having addressed all StageBanners 10 AT you may now start operating these via your DMX controller Note After switching on the StageBanner 10 AT will automatically detect whether DMX 512 data is received or not lf there is no data received at the DMX input the display will start to ash A001 with actually set ad dress This situation can occur if the 3 PIN 5pin XLR plug cable with DMX signal from controller is not connected with the input of the StageBanner 10 AT the controller is switched off or defective the cable or connector is defective or the signal wires are swap in the input connector 6 2 Stand alone mode The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be applied to the single fixture the fixture may be set to the master slave mode or controller mode or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master master mode and the rest as the slaves slave mode The slaves are assigned to SLA1 SLA9 and on the certain slave address can be connected only one fixture To set the fixture as the master or slave see the Addressing menu A001 Only one fixture can be set as the master
15. ized distributor The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails When rigging derigging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The device has to be installed out of the reach of people
16. k box Avoid interrupting the process Update status is being displayed in the list window When the update is finished the line with the text The fixture is successfuly updated will appear in this window and the fixture will reset with the new software Note In the case of interruption of the upload process e g power cut the fixture remains in the update mode and you have to repeat the software update again For example The fixture was switched off before finishing software upload After switching the fixture on again the fixture is still in the update mode and the display is dark Restart the Software Uploader program and repeat software update from your PC 9 Low power mode This mode omits fixture reset after switching the fixture on and lowers motor powers of the fixture Power down mode is useful in special cases e g if the fixture is ina ight case and you want to set its DMX address without taking it out from the case To enter Power down mode press and hold UP and DOWN and at the same time switch on the Power switch The following message appears on the display P d Mo Press ENTER to activate Low power mode without fixture reset Now you can set features and behaviour of the fixture by using A001 and Pers menu H you want to go to the normal operation mode execute a fixture reset 18 10 Error and information messages Mb Er This messsage informs you that the main PCB does not communicate correctly with
17. llation place is blocked when rigging derigging or servicing the fix ture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct holes only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fas tened The maximum ambient temperature 45 C must never be exceeded Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation CAUTION The maximum load of the device is 10 kg Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void 3 Description of the device RO ND ch 11 Quick lock fastener Omega holder Rotating plate Top covers Rear panel of the fixture 5 Power switch 6 Power cord 7 Fuse holder 8 3 pin DMX output 9 3 pin DMX input 10 5 pin DMX output 5 pin DMX input Front panel of the fixture 12 13 14 15 16 Mode button Enter button Up button Down button Display 4 Installation 4 1 Connection to the mains Verify the power supply settings b
18. odes Auto The fan automatically raises its speed in order to control inside temperature of the fixture if the temperature inside increases about certain level This cycle can repeat several times until the temperature inside is on a suitable level HIGH The cooling fan works on max speed max cooling PA Mo Pan movement mode Use this menu to set the character of the pan movement ti Mo Time mode The pan will pass its track in time that is set on the channel 3 SP Mo Speed mode The pan will pass its track with the speed that is set on the channel 3 In Po Init effect positions Select this function to adjust all effects to the desired initial positions After switch ing the fixture on if DMX is not connected all effects will move to initial positions Use the UP and DOWN buttons to select desired channel and press ENTER Set the effect to the desired position using UP and DOWN buttons and confirm by pressing ENTER After having adjusted required effects select Stor to save all values to the memory dF SE Default Settings Select this option to set all fixture personalities to the default values 8 5 Manual mode Select this menu to call up presetted positions of channel effects or direct control channel effects PrE C Presetted effect control Select this menu to call up presetted positions of the channel effects Man C Manual effect control Select this menu to control effects by control
19. ontrollers with other XLR out puts you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave Always connect output with the input of the next slave until all slaves are connected up to 9 fixtures Caution lt s necessary to insert the XLR termination plug with 120 Ohm into the input of the master fixture and into the output of the last slave fixture in the link in order to ensure proper transmission on the data link a 7 Na e we DMX512 DMX Controller t Controller operation 1200 Master slave operation 5 StageBanner 10 AT DMX Protocol version 1 0 Channel Value Function Type of control Pan coarse ia PAR Coarse control of pan movement by 360 proportional Pan Fine CEC 03859 Fine control of pan movement properional Pan speed Max speed tracking mode step Pan speed set Speed Mode in menu Pan Mode Speed from max to min
20. ram is available from the ROBE web site at WWW robe cz 2 Make a new directory e g Robe_Uploader on your hard disk and download the software to it 3 Unpack the program from the archive If the Robe fixture is produced in magnetic and electronic ballast version name of DMX Software Uploader is the same for both versions 2 Fixture software updating 1 Determine which of your COM port is available on your PC and connect it with to the DMX input of the fixture using the uploading cable Do not extend this cable Disconnect the fixture from the other fixtures in DMX chain Turn on the computer and the fixture 2 Switch the fixture to the update mode by selecting the option Updating mode in menu Special Functions on the fixture control panel SPEC gt UPd gt yES From this option you cannot return back to the main menu If you do not want to continue in software update you have to switch off and on the fixture to leave this option 3 It is recommended that you exit all programs before running the Software Uploader 4 Start the Software Uploader program Select desired COM and then click Connect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update If the option Incremental Update isn t checked all processors will be updated including processors with the same software version If you wish to update only later versions of processors enable the Incremental Update chec
21. the Control Board Fr Er This message will appear if the frequency of the main is not standard 50 or 60 Hz This message can appear as a result of the interference during the lamp starting if the lamp or igniter is old or as a result of the interference by neighbouring devices In these cases the message does not affect the fixture operating Po Er This message will appear if the fixture was shortly disconnect from the mains PA Er Pan movement error This message will appear after the reset of the fixture if the pan plate s magnetic indexing circuits malfunction sensors failed or magnet missing or the stepping motor is defective Or its driving IC on the main PCB The pan plate is not located in the default position after the reset MA Er Master error The message informs you that the fixture was addressed as a master and DMX signal is connected to its input Disconnect the DMX controller from fixture s input and address the fixture as the master again 11 Technical specifications Power supply EU model Voltage 208 230 240V AC 50 60Hz Fuse T 630 mA 230V US model Voltage 100 120 208 230 240 V AC 50 60Hz Fuse T 1 25 A 120V Power consumption 25 VA Electronics Addressing special functions setting via control panel with 4 digit LED display Readout fixture usage receiving DMX values temperature etc Built in analyzer for easy fault finding error messages Bilt in d
22. through the hole in the rotating plate and over the advertising banner holder Rotating plate Overhead installation 1 Bolt each clamp 1 not included to the omega holder 4 with M12 bolt and lock nut through the hole in the holder 2 Fasten the omega holders on the bottom of the base by inserting both quick lock fasteners 3 into the holes of the base and tighten fully clockwise 3 Fasten the safety cable 2 through the two apertures on the bottom of the base and over the trussing sys tem S SJ 1 Clamp eu 2 Safety cable 3 3 Quick lock fastener 4 Omega holder 4 4 DMX 512 connection connection between fixtures The fixture is equipped with both 3 pin and 5 pin XLR sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 3 pin or 5 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another DMX output DMX input XLR mounting sockets rear view XLR mounting plugs rear view 1 Shield 1 Shield 2 Signal 2 Signal 3 Signal 3 Signal 4 Not connected 4 Not connected 5 Not connected 5 Not connected If you are using the standard DMX controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX c
23. tion to turn the display by 180 d On This function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d lnt Select this function to adjust the display intensity 20 min 100 max bL Co Blackout during movement correction Select this function to enable the blackout during the head movement correction if the moving head lost its right pan tilt position for a short moment FEEd Pan feedback This function allows to return the mowing head to the required pan tilt position after changing the position by external force e g by stroke Be careful the Pan Feedback OFF is not the standard operation and the fixture can be demaged Note If the feedback was switched off the pan tilt position is changed by an external force and the feedback is switched on again the fixture might not to be synchronized with the DMX signal You have to make a reset in order to synchronize the fixture with the DMX signal Mi SE Microphone sensitivity Select this function to adjust the microphone sensitivity from 1 maximum to 20 minimum If the sensitivity is correctly adjusted the upper segment of the first digit blinks in the bass beat Examples I Z 17 I I IL ic underexited right level overexited upper segment blinks via a bass rhythm 15 Fan S Fan speed operating modes By using this function you can choose 2 types of the fan speed op erating m
24. u u ue ae 19 12 Maintenance and Cleaning een 20 CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOU INITIAL START UP 1 Safety instructions Every person involved with installation and maintenance of this device have to be qualilfied follow the instructions of this manual CAUTION Be careful with your operations With a high voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to en sure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Important The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug least Make sure that the power switch is set to Off position before you connect the device to the mains The power plug h
25. vector mode proportional Pan time set Time Mode in menu Pan Mode Time from 0 1 s to 25 5 s proportional Pan functions Standard operation fixture is controlled by channels 1 2 and 3 Reset of the pan Forward pan rotation speed is controlled by channel 3 Backward pan rotation speed is controlled by channel 3 Note for programming If you want to keep the same direction of the pan movent around 0 DMX 255DMX value the difference betwen the start point A and stop point B must not be greather than 120 85 DMX values If this difference is more than 85 DMX the pan will move in reverse direction 10 6 Operating modes 6 1 Controller mode The fixtures are individually addressed on a data link and connected to the controller The fixtures respond to the DMX signal from the controller The control panel on the front panel of the fixture allows you to assign the DMX fixture address which is defined as the first channel from which the StageBanner 10 AT will respond to the controller If you set for example the address to channel 5 the StageBanner 10 AT will use the channel 4 to 8 for control Please be sure that you don t have any overlapping channels in order to control each StageBanner 10 AT correctly and independently from any other fixture on the DMX data link If two three or more StageBanner 10 AT are addressed similarly they will work similarly For address setting please refer to the instructions under Addressin

Download Pdf Manuals

image

Related Search

Related Contents

Inhaltsverzeichnis - Lidl Service Website    USER MANUAL  Quinny 1473 User's Manual  Adaptadores de red Powerline  À l`attention de / To - Eurogroup Consulting  Cables Direct Cat5e U/UTP  Nederlands  Manual de Usuario AC-2710VHD PR  Zenoah EBZ5000RH User's Manual  

Copyright © All rights reserved.
Failed to retrieve file