Home
Portable-OM _EN
Contents
1. Owners Manual PORTABLE SPLIT AIR CONDITIONER ELECTRONIC REMOTE CONTROL ELECTRO MECHANICAL CONTROL AWPO AELIANO12 C11 AWPO AELIANOO9 C11 INSTALLATION AND OPERATING INSTRUCTIONS 1 1 2 PRINCIPLES OF 1 9 SAFETY LABELS OF THE 2 4 STRUCTURE mk 3 5 OPERATING METHODS tmien tperper i pene 4 X USAGE NOTICE g 4 X FUNCTIONS OF DISPLAY AND PANEL ee 5 6 NAMES AND FUNCTIONS OF REMOTE CONTROL T 7 ACCESSORIES AND INSTALLATION OF HEAT EMISSION DUCT 7 8 CARE AND MAINTENANCE l kisi funebri efa 9 9 11 6 12 TI AFTER SALE SERVICE 14 12 INSTALLATION AND MAINTENANCE OF HEALTH 14 This MOBILE AIR CONDITIONER a small portable air conditioner It has the functions of cooling drving and separate ventilation can be moved as necessary and at will It is fit for
2. There are several options for disposal a The municipality has established collection systems where electronic waste can be disposed of free of charge to the user b When buying a new product the retailer will take back the old product free of charge c The manufacturer will take back the old appliance for disposal at no cost to the user d As old products contain valuable resources they can be sold to scrap metal dealers e quality problems or any other problems arise please contact the local dealer Installation Instruction 1 Press and pull outwards handles of air inlet grille Health filter Air inlet grille Handle Filter Fig a 2 Place the health filter evenly on the air inlet grille as shown in Fig b Health filter Unregulated disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain 3 Reinsert the mounted air inlet grille with filter into unit m Cleaning instructions Take out the health filter before cleaning and reinstall it after cleaning according to the installation instructions Note that active charcoal cannot be cleaned with water Let filter dry in the shade or sun after cleaning but do not dry by wiping The health filter commonly has a usage lifetime of one year under normal conditions DISPOSAL Do not dispose of this product as unsorted municipal waste Separate
3. physical sensory or mental capabilities or lack of experience and knowledge unless they are under supervision or instruction concerning the use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance GPCO9AE K3NNA7A can be connected only to a supply with system impedance of no more than 0 328 ohms If case necessary please consult your electricity supply authority for system impedance information USER NOTICE 12 Wrong places Do tilt or overturn If an abnormal phenomenon occurres please pull out the power plug at once and ask the dealer to check and maintain Do not use an insecticide or other sprays which may cause deformation or cracks Check the User Manual for the sentences below and the marking label for the waste bin Meaning of crossed out wheeled dustbin do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding available disposal systems If electrical appliances are disposed of in landfills of dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposal free of charge Disposal of this appliance in domestic household waste is prohibited
4. collection of such waste for special treatment is necessary 13 USER NOTICE INSTALLATION AND MAINTENANCE OF HEALTH FILTER 14
5. d The LED displays The LED displays 11 TROUBLESHOOTING Possible Causes The power supply is not connected well The power plug is not inserted tightly Power plug or socket is malfunctioning The fuse is broken Is TIMER ON in operation The room temp is lower than the set temp The evaporator has frosted over The evaporator is frosted over Low voltage over current protection The water tank is full Solutions 1 Insert the power plug tightly 2 Have an electrician replace the power plug or socket 3 Have an electrician replace the fuse Cancel the SET TIMER operation or to wait until auto running 1 This is a normal phenomenon Unit is running in defrosting mode it will resume running in original mode after defrosting Unit is running in defrosting mode it will resume running in original mode after defrosting Cut off power supply after 10 minutes turn on the unit if ES still appears please call the maintenance man 1 Drain out water through drainage hose 2 If the malfunction persists please call the maintenance man Location Wrong places e Do not install the unit in a sealed place and keep well ventilated to avoid malfunctions Do not install the unit where it will be exposed to direct sunlight in order to avoid loss of efficiency Do not install the unit in a damp place which may cause electrical leakage Please do not
6. dry the air conditioner Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Location requirements The appliance shall be installed in accordance with national wiring regulations The appliance is for indoor use only but may not be installed in a laundry room Place the air conditioner on a smooth level floor that is strong enough to support the unit Allow at least 12 inches 50 cm of air space on all sides of the unit for good air ventilation 12 50 cm 12 50 min min Place the unit in an area where the temperature will not fall below 18 C 65 F The coils will be covered with frost at temperatures below 18 C 65 F and this may reduce performance NOTE The portable air conditioner has casters for easy movement but it should only be rolled on smooth flat surfaces Do not attempt to roll the portable air conditioner on a carpet or over objects OPERATING METHODS 4 METHODS USAGE NOTICE Electrical Requirements A WARNING Electrical Shock Hazard m Do not use an extension cord Do not use an adapter m Plug into a grounded 3 prong outlet Do not remove ground prong m Failure to follow these instructions can result in death fire or electric shock Power supply must be suitable for the rated voltage a
7. ety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you do not immediately A DANGER follow instructions You can be killed or seriously injured if you do not follow A WARNIN G instructions All safety notices will tell you what the potential hazard is how to reduce the chance of injury and what will happen if the instructions are not followed SAFETY LABELS OF THE UNIT 2 STRUCTURE Front Handle Control panel Rear 3 STRUCTURE Upper air inlet grille Heated air emission vent Lower air inlet grille ee ae OPERATING METHODS USAGE NOTICE The working range of COOL mode and DRY mode is 16 C 61 F 30 C 86 F The Max cooling operation temperature for the air conditioner is 35 C 95 F Unpacking the Air Conditioner A WARNING Excessive Weight Hazard m Use two or more people to move and install the air conditioner Failure to do so can result in back or other injury Remove packaging materials m Remove and properly dispose of the packaging materials Remove tape and glue residue from surfaces before turning on the air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and
8. home and office use especially for a house with many rooms With its compact configuration excellent workmanship elegant appearance it looks like a stationary Mercedes Benz car It is convenient to move energy efficient and has a low noise level Note Please read this manual carefully before operating the unit the manual is used for reference and the technical parameters are subject to change without notice Using the upper motor the indoor airflow passing through the evaporator becomes a cooled wind but with the help of lower motor the airflow of indoor passing through the condenser becomes a heated wind There are two duct systems designed in its structure The heated wind is discharged by the rear outlet and the cooled wind is discharged by the front outlet The principle of operation Cooled wind Evaporator Upper motor lt Airflow 1 Capillary Heated wind Lower motor Airflow 2 Condenser 1 SUMMARV Vour safetv and the safetv of others are verv important We have provided manv important safetv notices in this manual and on vour appliance Alwavs read and all safetv messages This is the safetv alert svmbol This svmbol warns vou of the potential hazards that can kill or hurt vou or others All safety notices will follow the saf
9. indow install the heat emission duct 2 Press MODE key to select COOL mode 3 Press 4 gt key to set the suitable temp16 C 61 F 30 C 86 F CAUTION When the unit is running in the COOL mode in order to maintain a good cooling effect please pay more attention to 1 If there is direct sunlight near the window please use the curtain to shield it 2 Do not use other heat sources in the air conditioned room DRY mode Please close the door and window in order to obtain a better dehumidifying effect Press the MODE key select DRY mode the unit will run in DRY mode At this time the upper motor runs at the low speed and its speed is not adjustable OPERATING METHODS 5 Length range of heat emission duct should be 50 150 cm It is recommended to use it with shortest length e When installed the emission duct should be as flat as possible Do not extend the pipe or connect it with other exhaust pipe which would cause abnormal operation Correct installation is as shown in figure When installing it on a wall height of wall should be about 40 130cm from floor 7 ACCESSORIES AND INSTALLATION EMISSION DUCT Wrong installation is shown in the following figure If the pipe is bent too much it could easily cause a malfunction Front plastic pipe end Rear plastic pipe end Window Emission Adapter Flexible Emission D
10. install the unit in the following places Places with gas fire oil or where a malfunction may occur Please pay attention the following people 1 Young children medically compromised people 2 People who have difficulty in expressing themselves 3 People who are very tired drunk or who have taken sleep medication Do step on or put anything on the top of the unit it will slow and a malfunction may occur Do not expose the body to a cold wind for a long time this can cause health problems The unit should be placed about 1 or more away from TV or it will be affected by its electromagnetic radiation The air inlet outlet must not be obstructed for this will cause a malfunction Do not insert your hands or a stick into the air inlet or outlet Pay more attention especially to young children otherwise an accident may occur e Ifthe supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard The appliance must be positioned so that the plug is accessible e Static air pressure in pipeline range must be 0 Pa to 25 Rated parameter for FUSE 250V AC 3 15A The appliance of conforms to GPCO9AE K3NNA7A GWP R410A R32 125 50 50 1900 When water level switch works for water filling water volume inside the tank is 1 2L This appliance is not intended for use by persons including children with reduced
11. nd have a special circuit for AC and diameter of the power cord should be large enough A time delay fuse or time delay circuit breaker is recommended All wiring must comply with local and national electrical codes and should be installed by a qualified electrician If you have any questions contact a qualified electrician m The wiring operation must be performed by the professional personnel by following national regulations There must be an electric leakage protection switch and magnetic and heat drop off air switch with enough capacity in a fixed circuit Do not connect earth wire to water pipe or gas pipe When the air conditioner is not used please pull out the power plug or cut off power supply Names and Functions Remote Controller COOL mode DRY mode LED screen FAN mode 88 6 MODE kev ON OFF kev j 179 lt gt ON OFF lt gt key 5 OPERATING METHODS OPERATING METHODS Control panel and the function 1 ON OFF key Press once to start and press once again to stop the unit 2 MODE key Press this button to change the operation mode in order of COOL COOL 3 4 key In COOL mode press 4 once the SET TEMP will decrease Press gt once the SET TEMP will increase by 1 C 1 F The SET TEMP can be selected from 16 C 61 F to 30 C 86 F COOL mode 1 To select a location near the door and w
12. uct ACCESSORIES AND INSTALLATION OF HEAT EMISSION DUCT 8 Portable unit There are casters at the bottom of the unit It can be moved around room very conveniently as necessary Air inlet grille WARNING Before maintenance please pull out the power plug and cut off power supply to avoid electric shock Clean the air filter Performance of the unit will decrease if there is too much dust collected so clean it at least once every two weeks Filter support Disassembiv Pull out filter support and take out filter cleaning e Wash the filter alone spray it clean e g shower attachment and shake it or immerse it into the mild soapy water then dry it in the shade 9 CARE AND MAINTENANCE Cleaning the air Please use a cloth that is slightly moistened with water whose temperature is below 40 C conditioner 104 F or soapy water or water with cleanser after wiping off dirt Do not use gasoline diesel oil or similarsubstance to clean the unit Before cleaning please pull out the power plug te Ge CARE AND MAINTENANCE 10 malfunction occurs please check the following before maintenance Troubles The air conditioner does not start Although it was set to COOL mode there is no cool wind Although it was setto DRV mode there is no cool win
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi de l`application GNS-8000A - LevelOne ISTRN 4865 Rev02 - NICE nice4you.gr Trust 4 Port Slimline USB 2.0 Hub Dlms vp user manual Xerox 4050 Printer User Manual 一般向けカタログ(PDF:1481KB) 商 品 仕 様 書 Behringer FCB1010 Preset List Copyright © All rights reserved.
Failed to retrieve file