1. Keypad List 1 OK Confirm 2 Return Cancel 3 Area Volume Pythagorean 4 Tilt Auto Level Auto Height Triangle area 5 Go Left 2 6 Go Right 7 Go up Addition 8 Go down Subtraction 6 9 Bluetooth 10 Reference Point ii 11 Menu le 12 Clear off Power off 13 Power on Measurement Reference Setup The default reference setting the bottom of the instrument Press mj to switch the reference point between the top bottom tripod and end piece of the instrument There is a beep warning tone when a reference point is changed The reference point will return to default every time when the unit is powered off I E the measuring reference point is from the bottom of the instrument every time when it s powered on Single Measurement Press to activate the laser Aim the laser at the object which is to be measured and press again to take measurement Results will be seen on the screen s display immediately Continuous Measurement max min distance Long press A to activate continuous measurement Under this mode minimum or maximum distance can be measured from a fixed measuring position by sweeping ideal points Note Continuous measurement will stop after 5 minutes Area Measurement Press once to activate area measuring function The symbol will appear on the display Press to take the first side distance measurement e g length Press again to take the second
2. AdirPro Flag 3 Laser Distance Meter User Manual Overview AdirPro Flag 3 laser distance meter measures up to 328 100m with 1 16 1 5mm accuracy integrates a tilt sensor and has an HD full color screen The screen is specially designed for professional users It s powered on a li ion battery which greatly enhances battery usage life and can last for several years In addition its green background color makes it visually pleasing to look at mOS V1 5 is an innovated and patented measuring system which has a vivid colorful screen strong interactive interface and professional measuring functions The various auxiliary functions and unique personal settings provide an excellent measuring experience The built in Bluetooth module transfers data from the Flag 3 to Android and iOS devices in real time and enables remote control and photo distance association The Flag 3 has the perfect combination of an ergonomic and modern design that gives it a beautiful look and comfortable grasp The Flag 3 is a leading laser distance meter heralding a new era of professional measurement Power on and off Power on Long press to power on the instrument and activate the laser The single measuring interface will be displayed on the screen Power off Manually i Long press to power off the instrument Power off Automatically The instrument will be power off automatically after three minutes of inactivity
3. The measuring points of the object which is to be measured should be on the same horizontal or vertical line 2 Put the device at a fixed but horizontally and vertically rotary tripod Indirect Measurement Pythagoras Two Points As shown Figure A if a user wants to measure the height of the pink line he can use Pythagoras Two Points to calculate the height 1 Press three times The symbol d will appear on display 2 Press to activate the laser and aim at the point which is to be measured 3 Press again to take the first measurement 1 and then again to take the second measurement 2 4 The height of the pink line third side of triangle first and second distance values will be seen on display Figure A Note 1 The device will automatically determine the longer distance as the triangle s hypotenuse and the shorter distance as the right angle side 2 When measuring the right angle side Distance 2 in Figure A user should ensure laser beam is right angled to the target line Indirect Measurement Pythagoras Three Points As shown in Figure B if the user wants to measure the height of the pink line he can use Pythagoras Three Points function to calculate the height 1 Press A four times The symbol will appear on the display 2 Press to activate the laser and aim at the point which is to be measured 3 Press again to take the measurements from first 1 second 2 an
4. be displayed in the result bar Bluetooth Flag 3 laser distance meter s Bluetooth function is used for interactions with Android and iOS devices on their corresponding App It can be used for data transfer remote control and more The following information is a guide to how to enable the Bluetooth function For more information and details on the function and operating steps please refer the Android or iOS App Users can go to Bluetooth functions by the following two methods 1 Shortcut Long press G until the Bluetooth icon flickers on the status bar This means Bluetooth is enabled and waiting for connection 2 Menu Press LEMI Use the arrow keys to navigate and select Bluetooth Then press Crd Press or F to switch the Bluetooth function on and off Press ELJ to save the setting or press LIT to quit the setting without saving Bluetooth APP downloading address www AdirPro net Menu Press MENU to go to the function menu which lists all of Flag 3 s functions by 3x3 icons per page Use the arrow keys to select the desired function Staking out Measurement Press EEM use the arrow keys to navigate and select Loft and then press OK Press or a to move the cursor and select the corresponding number Press i or W to increase decrease the value until the desired distance is reached Press ICL and start Staking Out measurement Move the instrument along the staking out line The screen will show
5. l Target too reflective use target plate or do not aim at Received signal too strong E strong light objective Measure value over range Please take measurements within its range Switch on off the device several times If the symbol still Hardware error appears your instrument is defective Please contact your distributor Function List and Specifications Specification pical measuring range 0 17 328 0 05m 100 m Typical measuring accuracy 1 16 1 5 mm Measuring units m in ft ft in Area Volume Pythagoras Add Subtract Tilt Auto level Auto Height Staking out Beep Bluetooth V1 5 Historical Data Button Class Button Life Button Type Battery Type Battery Life Laser class Laser type Ingress protection Operating temperature Storage temperature LCD Resolution USB Auto laser off Auto instrument off Dimensions Weight Note 1 000 sets Metal dome array 500 000times Membrane keyboards Lithium Battery 15 000 measurements Class 2M Il 635 nm lt 1mW IP65 0 C 40 C 10 C 60 C QVGA 320 240 Online upgrade Data export 30seconds 180 seconds 4 92 x 2 09 x 1 30 125 mm x 53 mm x 33 mm 5 64 oz 160g 1 Range The maximum measuring range is determined by the version of the meter Exact measuring range for the laser distance meter is shown on the gift box In poor daylight or reflection conditions please you the target plate or a better reflective surface Acc
6. selected record 3 Historical data lock unlock Usually the instrument saves a limited number of measurement data It will automatically delete the oldest data when new data comes in The data locking function enables the user to save data permanently unless the user deletes it manually from the memory Press EN or wW to browse the records Then press to lock and unlock the record Thermometer Press AEM Use the arrow keys to navigate and select thermometer Press OK The current temperature of instrument in the environment will be displayed on the screen Press to return to the menu Level Press EEM Use the arrow keys to navigate and select level Pres Three mercury columns represents the X Y and 45 axes The degree value is also displayed Press to return to the menu 1010 0 lt Press MENU Use the arrow keys to navigate and select Bubble Press OK Press E or w to select Yes or No This will switch the leveling bubble on and off Press OK to save the setting or press to exit without saving Measuring Unit Press MENU Use the arrow keys to navigate and select Unit Press cry Press t or w to change the distance unit between m ft in and ft in Press OK to save the setting or press to exit without saving Note System default measuring unit is m Angle Unit Press MENU Use the arrow keys to navigate and select Angle unit Press cra Press A
7. side distance measurement e g width The results of length width perimeter and area will be seen on the display Volume Measurement Press twice to activate the volume measuring function The symbol will appear on the display Press to activate the laser and aim at the target Press again to take the first side distance measurement e g Length Then respectively press to measure the width and height The resulting volume will be display in the summary line Addition Subtraction Distance 1 Take a measurement of a distance 2 Press the addition button A The next measurement s data will be added to the former one 3 Press the subtraction button v The next measurement s data will be subtracted from the former one This operation can be repeated The results will be displayed in the main area of the screen Area Volume 1 First take a measurement of area or volume 2 Press the addition button A and measure the second area volume This measurement will be added to the former one 3 Press the subtraction button E and measure the second area volume This measurement will be subtracted from the former one Indirect Measurement This device can measure distance to inaccessible points such as the distance to a wall which is blocked by obstacles or the height of a tree using a trigonometric function To ensure measuring accuracy indirect measurements should be based on the following conditions 1
8. the distance in real time When approaching the preset distance within 0 1m the instrument will start buzzing The status bar will show or icon to indicate which is the right direction to reach the appointed distance Press AEM Use the arrow keys to navigate and select Timer and then press cra Press El or ka to move cursor and select the corresponding number Press E or W to increase decrease the exact time value Press ELJ and start timing the measurement The countdown e g 10 9 8 is displayed and the last 5 seconds are counted down with a beep After the last beep the measurement is taken and the value is displayed mitsyce alors lim Dieters 1 View historical record Press EQ and use the arrow keys to navigate Select Record to call the function up Press A or F to select the measurment o and press ba to enter the record of this type Press or W to select one record and press to read the details The information displayed will include data type locked unlocked date time measurement function measurement types corresponding result and additional information 2 Delete historical record 1 Delete by batch CLEAR When viewing historical data when a measurement type is selected the user can press and then press CL to delete all the historical records belonging to this measurement type 2 Delete one by one CLEAR Press ES or Ez to browse the records Next press Eia and then LLG to delete the
9. d to third 3 points 4 The height of the pink line first second and third distance points values will be seen on display Figure B Note 1 The device will automatically determine the longer distance as triangle s hypotenuse and shorter distance as the right angle side 2 When measuring the right angle side Distance 2 in Figure B the user should ensure that the laser beam is at a right angle to the target line Angle Measurement Press button BN The symbol will appear in the function field As shown in Figure C Press to measure the tilt and the distance Figure C Auto Horizontal Measurement Figure D Press A twice The symbol will appear on the display Press A to measure the tilt and hypotenuse distance 1 The results of tilt distance of hypotenuse and two right angle sides will be seen on display Refer to Figure K Auto Height Measurement Figure E Press BN three times The symbol will appear on the display Press button to measure the distance to the top of the object bottom of the object distance of two hypotenuse and the height of object The results will be seen on the display Refer to Figure E Triangle Area Measurement 1 Figure F four times The symbol will appear in the function area Press As shown in Figure F press amp button to measure the three sloping sides respectively The area of triangle will
10. or 7 to select the desired unit 0 0 or 0 00 Press OK to save the setting or press to exit without saving Note System default angle unit is 0 0 Language Press MENU Use the arrow keys to navigate and select Language Press OK Press A or w to select a language either Chinese or English Press LY to save the setting or press to exit without saving Press MEET Use the arrow keys to navigate and select Const Press Crd Press or to move the cursor and select corresponding number Press ae or H to increase decrease the exact value Press LLG to save the setting or press to exit without saving Note All measuring results will be added or subtracted from the constant tolerance will be calculated into the result Beep Press EEM Use the arrow keys to navigate and select Beep Press OK Press t or w to select Yes or No to switch the beep function on or off Press LLY to save the setting or press to exit without saving G Sensor Press EEM Use the arrow keys to navigate and select G sensor Press OK The built in tilt sensor can be automatically calibrated Calibration requires two measurements on a level surface 1 Put the instrument on a flat surface then press OK button 2 Rotate 180 then press OK The sensor will then be calibrated Date Settings Press EEM Use the arrow keys to navigate and select Date Setting Press OK Press EN o
11. r v to select the corresponding place Press E or W to increase decrease the exact value Press LLG to save the setting or press to exit without saving Brightness Press EEM Use the arrow keys to navigate and select Brightness Press OK Press t or W to adjust the brightness Press OK to save the setting or press to exit without saving Reset Press EEM Use the arrow keys to navigate and select Reset Press OK Press E or w to select Yes or No to confirm whether you d like to reset the instrument Press OK to reset or press to exit without saving After resetting all personal settings will be deleted and will revert back to the default settings About Us Press EEM Use the arrow keys to navigate and select About us Press cra There is some relevant information about software such as software version number ownership and so on Go back to the menu system by clicking ES Troubleshooting Code Cause Corrective Measure Calculation error Refers to user menu repeat the procedures If cannot be solved after several times of reboot Currency for LD out of range meaning the instrument is out of order please contact your distributor Battery low Replace with new batteries High temperature Keep instrument within 32 F 104 F Low temperature Warm up the device to meet work conditions Received signal too weak Use target plate or change a good reflection measurement time too long
12. uracy In optimal conditions good target surface properties and room temperature the measuring range is up to 328 100m In unfavorable conditions intense sunshine poor reflectivity in target surface i e a black surface or high temperature variations the deviation over the entire 328 may increase 1 Maintenance Do not use aggressive cleaning agents or solutions Remove the battery before a long period of non use Warranty The AdirPro Flag 3 comes with a one year warranty from AdirPro More detailed information is available at www adirpro com Contact AdirPro 27 Selvage Street Irvington NJ 07111 Phone 845 738 1467 Fax 973 854 8650 Website www adirpro com
Download Pdf Manuals
Related Search
Related Contents
研削面が透けて見える! 作業効率が大幅に向上します。 無印良明 キッチンタイマー LaCinema Rugged HD Manual Sony Walkman WM-FX241 User's Manual CÁMARA DE RED DE INFRAROJOS PARA EXTERIORES Sangean WR-22 Ant-Pnl-16 Installation Guide Crestron electronic GLS-ODT-W-1200 User's Manual 3com 3CRWDR101A-75-ME router Copyright © All rights reserved.