Access Navigator Quick Start Guide

image

Contents

1. a Overview 4 Physical Installation 4 Electrical Connections and Cabling 5 Current Status and Settings 8 a Provision Access Navigator 9 a Provision GR 303 Switch DS1s 10 a Provision Drop DSIs 12 a Provision Groom DS1s 14 Provision Remote Access Bank II 15 Application Configuration Requirements 17 a Useful Maintenance Commands 18 a Alarm and Status Indicators 21 Quick Start Overview Overview This Access Navigator Quick Start Guide is intended for experienced installers and users who do not need the detailed installation and setup instructions provided in the User Manual For detailed information and instructions refer to the following chapters in the User Manual included on the CD ROM disk in the shipping box Chapters 2 3 4 Product Descriptions and Specifications Chapter 5 Physical Installation Chapter 6 Electrical Installation Chapter 8 Provision Access Navigator Chapter 9 Provision DCS Service Chapter 10 Provision GR 303 Service Chapter 11 12 13 Provision Remote Access Bank II and Adit 600 Chapter 14 Alarm Clearing Chapter 15 Diagnostics and Troubleshooting Chapter 16 Maintenance Procedures Chapter 17 Update Controller Card Software Chapter 18 CLI Language Reference Physical Installation Ensure adequate clearance and spacing for thermal cooling For detailed information refer to Chapter 5 in the
2. set the DSO type of all channels to data If the DS1 is terminated set the DSO type of any unused channels to match the DSO type voice or data configured on the device at the other end of the DS1 8 August 2003 Access Navigator Release 1 8 Quick Start Provision Access Navigator Provision Access Navigator Use the following commands to set up the Access Navigator for network operation and remote management set id lt id gt System Identifier or CLLI code set date lt mm dd yyyy gt Date with four digit year set time lt hh mm ss gt Time with 24 hour clock DCS units must be set manually but GR 303 units can be set by end office switch via EOC set ethernet ip address none Disable Ethernet interface if not used set ethernet ip address lt address gt Enable Ethernet interface lt mask gt set ip gateway lt address gt IP gateway address add user lt name gt Add user name set user lt name gt level lt access gt Access level 1 to 3 set user lt name gt password Password delete user lt name gt Remove user Access Navigator Release 1 8 August 2003 9 Quick Start Provision GR 303 Switch DSIs Provision GR 303 Switch DS1s Any DS1 port may be defined as a Switch Drop or Groom Switch DS1s connect to the end office switch for GR 303 operation To ensure that calls are processed properly the Terminal ID EOC and TMC settings must match those in the end office switch It is prudent to assign
3. Access Navigator User Manual Horizontal 19 Inch and 23 Inch Rack Mount Provide at least 4 37 inches 2 5 rack units of free air space above and below chassis for air circulation e Vertical Rack Mount Using Crossbars Provide at least 0 75 inch of free air space on left and right side of chassis for air circulation e Vertical Wall Mount Wall mounting is approved only for customer premises The Access Navigator requires free air space on top bottom and ends of chassis for air circulation Refer to detailed information in Chapter 5 4 August 2003 Access Navigator Release 1 8 Quick Start Electrical Connections and Cabling Electrical Connections and Cabling For detailed information refer to Chapter 6 in the Access Navigator User Manual 1 Power Connection ALWAYS Connect BOTH 48 VDC Connectors 2 Connect Building Ground to the chassis ground lug 3 Connect DSX 1 Cables Attach ferrite RF suppressors to both cables 4 Connect Ethernet Cable if used 5 Connect RS 232 Management Cable Attach ferrite RF suppressor to cable 6 Apply Power to Access Navigator DSX 1 Connector DSX 1 Connector DS1 Receive IN DS1 Transmit OUT Ethernet sesseseessesss S3sssssssssgesses pst Receive apes psi 3 Transmit it O Ethemet IN Alarm Out iming 1 ome Bem v ETE Alarmi n i 8 In Link OK gt 48V H o RA y A ee a Ground Lug Alarm Out Alarm In RS 232 CLI BIT
4. 2003 13 Quick Start Provision Groom DS1s Provision Groom DS1s The following commands are used to provision digital cross connects from a DSO on one DS1 to a DSO on any DS1 set dsl lt n gt lbo lt setting gt DS1 line buildout 1 to 9 1 to 5 for DSX 1 equalization 6 to 9 for attenuation set dsl lt n gt loopdetect lt on off gt Usually off for drop DS 1s disconnect lt n ch gt Remove old DSO connections eee PRI passthrough 14 August 2003 Access Navigator Release 1 8 Quick Start Provision Remote Access Bank II Provision Remote Access Bank II Use the online help to display available settings CET Commands set remote lt n gt config off Temporarily disable configuration downloading to remote Access Bank II dsl lt n gt type drop Provision DS1 service to remote ds1 lt n gt framing esf including remote management dsl lt n gt linecode b8zs interface dsl lt n gt remote mgmt cafdl dsl lt n gt lbo lt setting gt ds1 lt n gt loopdetect off dsl lt n gt id lt name gt remote lt n gt id lt name gt ds0 lt n ch gt type lt setting gt Provision DSO service to remote ds0 lt n ch gt signaling lt setting gt dsO lt n ch gt crv lt setting gt ds0 lt n ch gt up connect lt n ch gt lt n ch gt Provision DCS crossconnects to disconnect lt n ch gt remote read remote connections Read remote DSO connections read remote rs232 and interface settings read remo
5. Access Navigator QUICK START GUIDE Document Number 002 0108 0500 Product Release 1 8 August 2003 Copyright 2003 Carrier Access Corporation All rights reserved The information presented in this manual is subject to change without notice and does not represent a commitment on the part of Carrier Access Corporation The hardware and software described herein are furnished under a license or non disclosure agreement The hardware software and manual may be used or copied only in accordance with the terms of this agreement It is against the law to reproduce transmit transcribe store in a retrieval system or translate into any medium electronic mechanical magnetic optical chemical manual or otherwise any part of this manual or software supplied with the Access Navigator for any purpose other than the purchaser s personal use without the express written permission of Carrier Access Corporation Access Navigator Access Bank Adit and the Carrier Access Logo are registered trademarks of Carrier Access Corporation All other brand or product names are trademarks or registration trademarks of their respective companies or organizations Contact Information Carrier Access Corporation 5395 Pearl Parkway Boulder CO 80301 2490 Corporate Phone 800 495 5455 Fax 303 443 5908 www catrieraccess com Customer Support Direct 800 786 9929 E mail tech support carrieraccess com QUICK START GUIDE In this Guide
6. D4 or ESF B8ZS None CA IP controller management DS1 Adit 600 TDM IP mgmt Drop D4 or ESF B8ZS None DS1 lt n gt all other DS 1s point to controller management DS1 Access Bank II Drop D4 or ESF AMlIor None None not remotely provisioned B8ZS Access Bank II Drop ESF B8ZS None CA FDL remotely provisioned Access Bank I TR 08 or Drop SLC96 AMI or SLC96 None SLC 96 TR 08 Shelf A B8ZS SLC 96 TR 08 Drop SLC96 AMI or None None Shelf B C D B8ZS Access Navigator Release 1 8 August 2003 17 Quick Start Useful Maintenance Commands Useful Maintenance Commands Category CLI Commands Context sensitive help available help at any time Display configuration settings show autoexit show clock show connect show crv lt range gt show date show dsO lt n ch gt show dsl lt n all gt show eoc show ethernet show id show interface lt name all gt show ip show isdn crv lt range gt show remote lt n all gt show remote lt n gt connections show snmp show switch show time show tmc show users whoami Read remote Access Bank IT remote connections DSO connections and interface remote rs232 settings remote t1 remote tidrop Note SDSL interface port has no remote v35 settings to read remote alarms 18 August 2003 Access Navigator Release 1 8 Quick Start Useful Maintenance Commands Category CLI Commands Display current information status clock about an interface status crv lt range gt st
7. S Timing In 48V B Input 48V A Input Start Management Session 1 Connect PC to RS 232 Management Cable 2 Set Terminal Emulator to ANSI ASCII VT100 no flow control local echo off 9600 8 None 1 3 Press CR Enter key on PC to produce Command Line prompt 4 Log In If security is enabled you will be asked for your user name and password Access Navigator Release 1 8 August 2003 5 Quick Start Using the Command Line Interface CLI Using the Command Line Interface CLI Online Help Online help for CLI commands is available any time you are logged into the Access Navigator You can display basic commands and obtain context sensitive help with additional detail To display a list of basic CLI commands just type a question mark You can also type the word help and press the Enter or Return key on the terminal Help for a specific CLI command is available by typing help before the command word or words in the partial command pressing the Enter or Return key It is usually easier to type a question mark after the partial command The partial command will be repeated so that you can easily add the next value or key word Context sensitive help does not work for command words taken out of context Text Conventions Input commands and keywords in this guide appear in a bold typewriter font as in the following example set dsl 1 4 up If a command requires you to enter additional information an italic typewr
8. S1 line buildout 1 to 9 1 to 5 for DSX 1 equalization 6 to 9 for attenuation set dsl lt n gt fdl lt none sl1c96 t1403 gt DS1 FDL type set dsl lt n gt remote device mgmt Management link for remote lt none cafdl caip lt ipaddress gt ds1 n gt Access Bank II and Adit 600 set dsl lt n gt remote device mgmt Enables call communications caip lt ipaddress gt pphone channel for remote Adit 600 providing P Phone service set dsl lt n gt loopdetect lt on off gt Usually off for drop DS 1s set dsO lt n ch gt type lt voice data gr303 gt DSO type set ds0 lt n ch gt pphone P Phone channels 12 August 2003 Access Navigator Release 1 8 Quick Start Provision Drop DSIs set dsO lt n ch gt isdn lt bl b2 d gt crv ISDN BRI 4 1 TDM channels lt range gt set dsO lt n ch gt isdn none Unassign ISDN channels show isdn crv lt range gt Show ISDN CRVs send switch provision request If RDT is enabled on Switch show isdn database Show ISDN provisioning set dsO lt n ch gt crv lt range gt Assign CRVs in sequential order set dsO lt n ch gt crv lt range gt s1c96 Assign CRVs in odd even slc96 order connect lt n ch gt lt n ch gt Connect ISDN D channel to the switch disconnect lt n ch gt Remove cross connect show connect lt n gt Show current cross connects set dsO lt n ch gt up Set DSOs in service set dsl lt n gt up Set DS1s in service Access Navigator Release 1 8 August
9. atus ds0 lt n ch gt status dsl lt n all gt status dsl lt n gt performance status dsl lt n gt performance history status eoc status equipment Check IP connectivity Ping lt ipaddr gt Display all alarms alarms Display selected alarms alarms lt major minor alert gt Display all log events except BERT TMC and Configuration change events Display selected logs lt major minor alert info gt dsl lt n gt dsl lt n gt lt major minor alert info gt equipment equipment lt major minor alert info gt info bert config config ds0 lt n ch gt config dsl lt n gt config crv lt value gt config source lt cli eoc snmp icc gt tme tmc permanent tme crv lt value gt Access Navigator Release 1 8 August 2003 19 Quick Start Useful Maintenance Commands Category CLI Commands Clear logs bert log blocked call count config log dsl lt n gt performance log peak call count permanent call count remote lt n gt log tmc log Controller switch switch controller Reset both Controllers reset all Reset only standby Controller reset standby Reset a DS1 framer reset dsl lt n gt Reset remote Access Bank II reset remote lt n gt Restore factory defaults restore defaults Test alarm functions and produce set alarms lt critical major minor gt alarm messages lt on off gt Test DS1 circuits with csu lt loopup loopdown gt loopbacks line lt loopup loopdown gt network lt loopup loopdown
10. gt niu lt loopup loopdown gt payload lt loopup loopdown gt Send test pattern send dsl lt n gt line lt p2e11 p2e15 p2e23 qrss gt send dsl lt n gt payload lt allones allzeros 11in8 p2e11 p2e15 p2e23 qrss gt Turn off test pattern send dsl lt n gt off Perform automatic BER test and send dsl lt n gt line display test result lt p2e11 p2e15 p2e23 qrss gt test Note Test pattern will turn off send dsl lt n gt payload lt allones allzeros when test is complete 1in8 p2e11 p2e15 p2e23 qrss gt test 20 August 2003 Access Navigator Release 1 8 Quick Start Alarm and Status Indicators Alarm and Status Indicators For alarm clearing producers and detailed indicator descriptions see Chapters 14 and 15 in the Access Navigator User Manual Normal LED states are shown in Boldface type Power 48V power failure Two LEDs one for Internal power supply failure each Controller card Card is booting up Normal operation Active Controller Off Controller card is standby Green Controller card is active Yellow Insufficient memory SIMM memory module is required Critical Alarm No critical alarms present Critical alarm exists Major Alarm No major alarms present Major alarm exists Minor Alarm No minor alarms present oe Minor alarm exists ACO alarm cut off Alarm s active ae Alarm s suppressed DS1 Status Off line ae Loss of signal LOS Each Quad T1 Framer Red F
11. iter font is used to show what item or items are required Each item will be enclosed in lt gt symbols as in the following example requesting a number n and a setting value Do not type the lt gt symbols set dsl lt n gt lt setting gt If you must enter one item from a list the items will be separated by vertical lines as in the following example request you to select either up or down Do not type the lt gt symbols set dsl lt n gt lt up down gt Online help does not use italic or bold type 6 August 2003 Access Navigator Release 1 8 Quick Start Using the Command Line Interface CLI Entering DS1 and DSO Numbers and Ranges Commands containing ds1 lt n gt require you to enter a DS1 number 1 to 32 ora range of DS1 numbers For example DS1 6 is entered as ds1 6 To enter a range of DS1s type the starting and ending numbers separated by a hyphen For example DS1s 1 through 8 can be specified by typing ds1 1 8 Commands containing dsO lt n ch gt require you to enter a DS1 number 1 to 32 and DSO number 1 to 24 separated by a colon For example the channel list for DS1 4 and DSO channel 8 would be entered as dsO 4 8 The channel list may also contain a range of DSO channels For example DS1 6 and DSO channels 1 through 12 would be entered as dsO 6 1 12 A colon follows the DSI number and the beginning and ending DSO channels are separated by a hyphen Command Shortcuts Tabbing Tabbi
12. lashing Slow Out of frame or AIS card has four LEDs Red Flashing Fast Self test failure Yellow Lince code violation LCV Yellow Flashing Yellow alarm Green Normal operation Green Flashing Loopback test in progress Ethernet No link or connection on rear panel Normal operation Access Navigator Release 1 8 August 2003 21 Quick Start Alarm and Status Indicators 22 August 2003 Access Navigator Release 1 8
13. ng is a shortcut for typing commands CLI allows the user to enter partial command fragments then press the Tab key For example if you type stat equip or just st eq and press the Tab key the CLI will respond with status equipment If this is correct press the Enter or Return key to execute the command For corrections use the Backspace Delete and Escape keys You can Tab after typing each fragment or after typing a series of fragments The CLI will re echo the command each time you press the Tab key When you are satisfied that the command is correct press the Enter or Return key Tabbing will not substitute a word that does not represent a valid command or attempt to correct numbers such as 9 1 8 or strings enclosed in quotes such as AcmeCorp Keyboard Shortcuts e Ctrl F Forward displays next command line e CtriR Reverse displays previous command line e Esc Escape cancel CLI command without entering Access Navigator Release 1 8 August 2003 7 Quick Start Current Status and Settings Current Status and Settings status equipment Show equipment configuration show dsl lt n all gt Show service status show dsO lt n ch gt show isdn crv lt range gt show isdn database status dsl lt n gt status ds0 lt n ch gt set dsl lt n gt down Set unused circuits out of service set dsO lt n ch gt down down If the DS1 is not set dsO lt n ch gt type lt voice data gt terminated
14. te t1 read remote tldrop Note SDSL interface port has no read remote v35 settings to read add interface lt name gt lt n ch gt Create fractional interface and assign DSOs to be used set remote lt n gt rs232 lt setting gt Configure remote interface port set remote lt n gt tldrop lt setting gt to meet customer requirements set remote lt n gt v35 lt setting gt Access Navigator Release 1 8 August 2003 15 Quick Start Provision Remote Access Bank II CIT Command connect remote lt name gt lt port gt Connect fractional interface to disconnect remote lt name gt remote interface port set remote lt n gt config on Download configuration set ds0 lt n ch gt up Set DSOs in service set ds1 lt n gt up Set DS 1s in service 16 August 2003 Access Navigator Release 1 8 Quick Start Application Configuration Requirements Application Configuration Requirements Permissible Selections Application DS1 DS1 Line Framing Code FDL Voice to GR 303 switch B8ZS None None 4 Voice or data to DCS switch Groom D4 or ESF AMI or None None B8ZS Voice or data to subscriber drop Drop D AMI or None None B8ZS Voice or data to subscriber drop Drop AMI or None or None B8ZS T1403 ESF Adit 600 TDM FDL mgmt Drop ESF B8ZS None CA FDL controller management DS1 Adit 600 TDM FDL mgmt Drop ESF B8ZS None DS1 lt n gt all other DS 1s point to controller management DS1 Adit 600 TDM IP mgmt Drop
15. the Primary and Secondary Switch DS1s to different Quad T1 Framer cards set switch type lt 5ess dms generic gt Ensures switch compatibility set clockl lt bits dsl n internal gt Primary and Secondary system set clock2 lt bits dsl n internal gt clock sources BITS is recommended where available or where transport to the end office switch is via a SONET network interface group set dsl lt n gt id lt id gt 1 to 5 for DSX 1 equalization set dsl lt n gt fdl none Switch DS1 FDL is always none 10 August 2003 Access Navigator Release 1 8 Quick Start Provision GR 303 Switch DS1s eoc primary lt n ch none gt EOC channels are normally eoc secondary lt n ch none gt assigned to primary and secondary DS1s and use DSO 12 tmc primary lt n ch none gt TMC channels are normally tmc secondary lt n ch none gt assigned to primary and secondary DS1s and use DSO 24 set dsO lt n ch gt up Set DSOs in service set dsl lt n gt up Set DS 1s in service Access Navigator Release 1 8 August 2003 Il Quick Start Provision Drop DSIs Provision Drop DS1s Drop DS1s provide service to Customer Premises Equipment such as Access Banks Adit 600 terminals CSUs and PBXs CUI Commands Customer Premises set dsl lt n gt framing lt d4 esf slc96 gt set dsl lt n gt linecode lt ami b8zs gt set dsl lt n gt id lt id gt set dsl lt n gt clock lt normal loop gt set dsl lt n gt lbo lt setting gt D

Download Pdf Manuals

image

Related Search

Related Contents

Paulmann Gryps  Menu Management User Guide Menu Location Menu Design Menu  Samlex PSC1600-3500 Manual Rev1endfs  Interfacing a Hard Drive to an M5249C3 Board Page 1. Freescale  USER`S MANUAL - BTD Car Tools  Philips UV water purifier WP3892/01  DL1640 User`s Manual  78K0S/Kx1+ Sample Program (8-bit Timer 80) Interval Timer AN  

Copyright © All rights reserved.
Failed to retrieve file