1. Tracker parameters These parameters are directly important for Nano positioner Parameters are factory set according to used actuator motor Do not change values unless you are sure what you are doing Max and min range limits the moving of the motor at positioner level These settings should be the same as those on controller tab see chapter 20 I motor limitation is maximum permited current in positioner Do not set greater than 5 Amps hardware limit U I measuring factors are measuring calibration factors for voltage and current measurement in positioner We do not encourage you to change these values Rest timeout position A B When RS485 communication fails due to any reason each positioner tracker can go to some predefined rest position by itself and so set panels to the best position for catching the Sun as fixed panels until communication is repaired Timeout can be set in seconds 0 disabled feature Modbus timeout is similar like Rest timeout but it just indicate communication failure by turning orange LED on front panel of positioner Nano Status can not be seen on the web if communication fails Reference timeout means how long motor is going from totally extended position to totally closed position This is maximum permited time for motor to go to the reference If this time is exceed reference error is set in tracker status i e free motor 6 Sigma user manual_rev1 25 Manual mode
2. Selected tracker can be also manually controlled for the service or installation purpose Enter impulses number for each axis and press enter or send button Stop button will immeadiatelly stop the moving Home A B lt will proceed synchronization for both axis manual reference see also chapter 12 Button clear status lt will clear any error in the selected Nano positioner see chapter 8 In the case of any error seen on monitoring lt tab first remove that error than clear the status Monitoring ID Ver O1 2 451 02 2 451 03 2 451 04 2 451 O35 2 451 06 2 451 Of 2 451 O08 2 451 O09 2 451 10 2 451 11 2 451 12 2 451 13 2 451 14 2 451 15 2 451 16 2 451 1 2 451 18 2 451 19 2 451 20 Z 21 2 451 Ce 2 451 23 2 451 24 2 451 26 Monitoring I A 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 0 000 Remain A 20 7 1 Position amp Destination amp Remain B Gael 7 990 70074 folo foe43 033 FoF Fool 70610 fafa gala 9203 raag Faaa Pages fo616 70092 71700 70004 Fogel 76056 fO6143 70229 70311 rogi 7 986 700693 fo165 70248 Pies ogar fooll 70607 7o00 Fala 20 340 fats foole 75613 7097 fafou 79079 Panan 760534 rola 70233 mE O oO O oC O PS O FS O FS O PaS O FS O aS O mS O PS O Prg nE Position B E O paS O RR CO RR O PFS O Ree O Ree O R
3. 7 CERKLJE SLOVENIA EU C Phone 386 4 281 62 00 Fax 386 4 281 62 12 di A R vas REE aia www solar motors com mailto support sat control si Copying is prohibited Product is patented and protected by the Copyright Law SunTracer is a registered trade mark of the Sat Control company All rights reserved Sigma user manual_revi 1 1
4. ONITORING CONTROLLER TRACKERS A EATHER SYSTEM ABOUT Wind parameters Position 4 lo Position B Reserved Fall time min Threshold km h 40 Koeficient Other parameters Radiation koeficient fi 3200 Reserved Temperature koeficient fo 100 Temperature offset 30 0000 Sae Monitoring Wind speed km h 2 2 Solar radiation W m2 166 Temperature C 8 Program is intelectual property of Sat Control d o o Usage is allowed strictly with Sat Control s product Any distribution copying or modifying are prohibited You can buy the program on our web page Tab is holding parameters of external weather sensors Press save button after changing to save new parameters To dischart browse to some other tab 27 Wind If the wind is strong enough it could damage the panels Therefore it is suitable to move the panels into wind save position normally in horizontal position when wind speed_is over threshold At first exceeding threshold will put panels to position A B If the wind is below the threshold for the fall time it will turn to normal tracking Wind sensor should be voltage output type 0 10V not impulsed nor current loop 4 20mA type Koeficient value means sensor output voltage per each 1km h sensor constant 28 Other parameters Second two sensors are radiation and temperature sensors They are also voltage output type 0 10V e Radiation koeficient is
5. Password Login By the first connection to Sigma s IP log in page will appear There are two different kind of logins Admin and User admin account can change everything needed to control setup adjust service the trackers and Sigma It is owner s and installer s account with full rights Default password is admin e user accound can only see values but can t change anything It is meant for visitors or non priviledge people to see power plant tracking system as demo Default password is user Passwords can be changed in accounts ini file on SD card Monitoring tab Bootloader version 1 007 Application version 1 124 Date 19 12 2011 10 00 IGMA SOLAR TRACKER SERVER WEB BASED You are logged in as User Logout I MONITORING Eeo ionia TRACKERS WEATHER SYSTEM Trackers Time 15 37 04 w B E a a 6 7 8 Date 24 01 2012 voltage 24 035 Y E 10 ED B a a as 16 Current 0 000 A E a8 a9 20 a E E 24 Wind speed 0 0 km h Solar radiation 590 Wim2 25 26 EJ a 29 30 a z Temperature 11 i Ea a4 amp 36 A 38 39 40 Angle A 47 33 a la a2 aa aa as a6 a7 a Destination A 248815 pls Angle B 14 11 49 50 51 52 53 54 55 56 Destination B 260000 pls E 38 59 60 61 62 63 64 Operating mode TRACKING MODE Program is intelectual property of Sat Control d o o Usage is allowed strictly with Sat Control s product Any distr
6. SAT CONTROL D Want to get more Sigma user manual Document Rev 1 Sigma is main master controller for tracker network in large scale solar power plant applications It is directing and supervising up to 64 slave positioners Nanos User can control whole tracker s network via integrated web pages he H a i gt un 11 t R 2 M anad lt s matarme W 75 405 com M Sa PW ver oS meen ver Rrtitioney Meant Morac er asa aTe Solar Tracker Server Mozilla Firefox File Edit Yiew History Bookmarks Tools Help Solar Tracker Server gt 243 150 195 56 1100 Bootoader version 1 004 f M Application version 1 121 ka Date 16 12 2011 11 30 SOLAR TRACKER SERVER WEB BASED You are logged in as Admin Logout MONITORING Wesi Sys ste BS ele a alk ot 8 ol a e r 15 22 40 24 01 2012 23 247 0 000 Date Voltage Current Wind speed 0 0 Solar radiation 0 Temperature 30 Angle A 44 17 Destination A 256242 Angle B 0 00 Destination B 0 Operating mode TRACKING MODE Program is intelectual property of Sat Control d o o Usage is allowed strictly with Sat Control s product Any distribution copying or modifying are prohibited You can buy the program on our web page Sigma user manual_rev1 1 Login page GMA Application version 1 124 SOLAR TRACKER SERVER Please enter your username and password Username
7. _rev1 3 Controller tab Bootloader version 1 007 Application version 1 124 Date 19 12 2011 10 00 s SOLAR TRACKER SERVER WEB BASED You are logged in as Admin Logout PIS PGteibicms CONTROLLER Riise qs 200 aed On 8 le 1 en User parameters Longitude haoo Latitude aes Panel wide cm Woo Panel space cm Woo Night position amp ooo Night position B 450000 Reference interval A days fo ooo E Reference interval B days Booo Day mode time hhmm beo ti itsti s S Night mode time hhmm je200080Ft t i N Moving interval min ie Group eooo Max output current 4 eooo Reserved Installer parameters ALA 610000 ALB fi4oo000 8 A2 A eaz 0000 A2 B s2000 A3 A ooo A3 B 530000 2 t A4 A hason ooo A4 B hooo ooo A5 A ooo i ts A5 B foooo0 ts A6 A Woo A6 B boon B1A 200000 0tt Ctits B1B boon B2 A P00 B2B boo Gear ratio A 2940000 i Gear ratio B 2340000 Coordinate mode a Coordinate mode B ee Geometry mode poe Geometry mode B pa Motor max range pls eoon Motor max range B pls eoon Motor min range A pls 500 Motor min range B pls 500 U supply factor boas Reserved eee Program is intelectual property of Sat Control d o o Usage is allowed strictly with Sat Control s product Any distribution copying or modifying are prohibited You can buy the program on our web page Tab is used to
8. ber which is send to tracker s network It is strongly depended on a geometry in use Destination has diagnostic purpose 7 Operating mode Informs in which mode Sigma and trackers are Tracking mode means normal following the Sun Calculations are proper If motor does not run and there are no errors it could be that Sun is still not inside the moving range of the tracker geometry morning afternoon Night mode means that trackers are moved into night position and will not track the Sun while the Sun is below the horizon Night mode times can be set in Controller tab see chapters 13 14 Wind mode is automatically entered when there is too high wind outside and tracker needs to be moved into the wind safe position For this feature wind sensor must be installed and parameters need to be set weather tab 8 Tracker status Each tracker represent one cube coloured according to the status of that tracker to clear status see chapter 25 e Green tracker is OK Red tracker has some errors and therefore it is not moving Grey there is no response from that tracker Status can not be read Communication problem or no power on the tracker By clicking on each cube a pop up window opened showing current values and descrption of the status ID 01 Version 3 007 Voltage 23 643 Current 0 000 RemainA 0 Position4 87611 Destination4 87584 RemainB 0 PositionB 238093 Tracking enabled Sigma user manual
9. calculated as Koef max_radiation max_voltage 0 011 Example if sensor measures from 0 to 1200W m2 and has range from 0 10V the Koef 1200W 10V m2 0 011 1 32 Temperature koeficient is calculated as Koef max_temp_range max_voltage 0 011 Example if sensor measures from 30 C to 70 C it means that max_temp_range is 100 C Therefore 100 C 10V 0 011 0 11 Temperature offset is temperature at OV on output In this example 30 C 29 Monitoring Shows output data of the sensors 8 Sigma user manual_rev1 System tab Bootloader version 1 007 Application version 1 124 Date 19 12 2011 10 00 SOLAR TRACKER SERVER WEB BASED You are logged in as Admin Logout MONITORING CONTROLLER TRACKERS WEATHER atiu ABOUT Network parameters IP address fi92 168 1 Netmask 255 255 255 0 Gateway i92 168 1 10 MAC address fi 6B5ES5AF 766A Server parameters Server IP address 86 61 66 230 Server port fico ooo Update path jupdate_nano Update interval min piee Update time start hhmm o0 Update time end hhmm joao Reset time hhmm mo Reserved a Clock Time hhmmss 145647 Set Date ddmmyyyy 24012012 Set Program is intelectual property of Sat Control d o o Usage is allowed strictly with Sat Control s product Any distribution copying or modifying are prohibited You can buy the program on our web page Tab is holding system and network parameter
10. ee O FaR O P O PaE O PeR RE Destination B O ESS O PFE O RR O Ree O RR O RR O PFE OCCURS O PS O FaR O FaN eee Enable all Disable all Status 5 oxcoocooon B oxooooo1co fi OxOOO00000 RN OxO0000000 ae OxOO000000 zz OxOO000000 at OxO0000100 E OxOOO000100 B OxO0000000 Bal OxOOO000000 a OxO0000000 AA OxO0000100 Zz E M H a a To overview some important values from all trackers Similar as on monitoring tab but more detailed Meant for diagnostic purpose First few columns have tracker s ID firmware version of the positioner Nano voltage and current of the tracker sum of these currents is shown on the monitoring tab see chapter 3 Remain A B is last synchonization misalignment after doing reference A B Position A B is motor position destination A B are last received destination from Sigma Status of each tracker here is represent as HEX value advanced information See chapter 8 for tracker status e S status green red gray see chapter 8 M some motor is moving H doing reference synchonization T tracking enable green cube disable no cube Enabling disabling for all trackers at once can be done with button Enable all and Disable all Sigma user manual_rev1 7 Weather tab Bootloader version 1 007 Application version 1 124 Date 19 12 2011 10 00 amp SOLAR TRACKER SERVER WEB BASED You are logged in as Admin Logout M
11. ibution copying or modifying are prohibited You can buy the program on our web page This tab is default tab and will be used in normal working condition of solar power plant 1 Time and date Current solar time for your location see geo longitude latitude Note that this time could differ from your zone time It is correct only for your accurate geo longitude If Sigma has access to NTP server on internet this time will be set automatically Otherwise you need to set it manually in system tab see chapter 32 Date is today 2 Sigma user manual_rev1 2 Voltage Shows the power supply voltage for Sigma Nanos could have different voltages than Sigma if different power supplies were used for trackers 3 Current It is sum of all currents from all Nanos trackers motors This is used for monitoring maximum allowed current which can be set in controller tab Suitable when there is one power supply for many trackers and has some current limitation Trackers will be controlled not to exceed a maximum permited current Sigma s current is too low and is not included 4 Wind speed solar radiation and temperature Shows weather data directly from external sensors if they were in use Setup can be done in weather tab 5 Angle A B Currently calculated angle of the Sun Zero degrees mean true South negative values are East side positive West side For one and two axis trackers 6 Destination A B Calculated num
12. l do the sychonization Synchonization is done at day mode time 4 Sigma user manual_rev1 13 Day mode time Is the hour when tracker starts to track Before this hour it waits in the night position Recommended value is 6 14 Night mode time Is the hour when tracker stops to track and goes to night position Recommended value is 22 15 Moving interval It means at what interval the solar tracker will correct its position to trace the sun The minimum value is 1 minute maximum is unlimited Recommended value is 5 minutes 16 Group How many trackers are controlled with this Sigma Value can not be changed Number of trackers is number of licences Licences needs to be bought See www solar motors com for your reference or contact information below this document This number directly influences on number of coloured boxes on monitoring tab 17 Maximum output current Sigma will controll such number of trackers at once until sum of all tracker s currents reaches maximum permited Suitable when there is one power supply for many trackers and has some current limitation This number is setting value monitoring value can be seen on Monitoring tab see chapter 3 for additional information 18 Geometries Different trackers have different geometries Geometry includes parameters A1 A6 B1 B2 and number of selected geometry geometry mode Note In the case of using our tracker parameters are already set Do no
13. n buy the program on our web page This tab has informations about the owner Tab is not seen when logged on with user account only admin can see it Fields can be changed in file about ini on SD card Micro SD card There are few important files stored in this Micro SD card Sigma needs to be powered off before pulling the card out System ini holds Sigma s network data Please refer to chapter 30 for additional information Default values are TCP IP ip_address 192 168 0 10 ip_netmask 255 255 255 0 ip_gateway 192 168 0 1 Note MAC address needs to be unique Do not change it Accounts ini holds passwords for login accounts Please refer to chapter login page for additional information Default values are admin admin admin user user user 10 Sigma user manual_rev1 About ini have owner s information Please fill in the informations about company Your Company address Middle street 10 1234 City latitude 45 0 longitude 15 0 phone1 003861234567 phone2 003861234567 cperson My Name Note in the case of a new SD card use up to 2GB Micro SD card or lower Formating needs to be FAT32 512kB Volume label New Volume File system FAT32 v Allocation unit size 512 z V Perform a quick format Enable file and folder compression Cancel SunTracer is registred trade mark of company Sat Control All rights reserved Manufacturer SAT CONTROL d o o Pozenik 10 SI 420
14. ogged in as Admin Logout MONITORING Me NOimeeee TRACKERS WEATHER SYSTEM ABOUT Device Enter device ID Send Tracker info Device ID i 17425949 Serial number Software version Tracker parameters Motor min range A pls foo Send Motor min range B pls foo Send Motor max range pls sooo Send Motor max range B pls 260000 Send Rest position A pls fi3o000 Send Rest position B pls i3000 Send I motor limitation 4 4 ooo Send I motor limitation B 4 4000 O Send U measuring factor es000 Send I measuring factor 28 000 Send Rest timeout sec boo Sem Modbus timeout sec boo SS en Reference timeout sec fso Send Reserved o Manual mode Enter destination A pls Send Tracking enable disable Clear status Enter destination B pls Send Home A Home B Stop motor Save This tab has direct access to each positioner Nano tracker Some settings are very sensitive and wrong values can cause damage of trackers Press save button after changing to save new parameters To dischart browse to some other tab 22 Device Select which tracker you want to see Enter a number and press enter or click on send button 23 Tracker info Device ID means which tracker is currently selected monitored see chapter 22 Additional information are serial number and software firmware version of selected Nano 24
15. s of Sigma Web access is conditioned by these parameters Press save button after changing to Save new parameters To dischart browse to some other tab 30 Network parameters Shows currently set IP address netmask gateway and MAC address for Sigma Due to security reason they can not be changed via web page but owner can set them directly on SD card system ini file NOTE Do not change MAC address 31 Server parameters These parameters are meant for upgrading After newer firmware is available from our company Sigma can automatically download the file and upgrades itself or positioners trackers We do not encourage you to change these values 32 Clock Set current clock and date manually Be careful to enter proper format hhmmss and ddmmyyyy Example 12 23 30 12hours 23minutes and 30 seconds 122330 16 April 2011 16042011 Sigma user manual_rev1 9 About tab Bootloader version 1 007 Application version 1 124 Date 19 12 2011 10 00 SOLAR TRACKER SERVER WEB BASED You are logged in as Admin Logout MONITORING CONTROLLER TRACKERS tittle ei OB OUT pa information Company our Company Address Middle street10 1234C Latitude jso Longitude h50 Phone 1 003861234567 Phone 2 003861234567 O Contact person My Name Program is intelectual property of Sat Control d o o Usage is allowed strictly with Sat Control s product Any distribution copying or modifying are prohibited You ca
16. setup tracker s behaviour and geometry Some settings are very sensitive and wrong values can cause damage of trackers Press save button after changing to save new parameters To dischart browse to some other tab 9 Longitude latitude Mean your geographical longitude and latitude They are both important in order to get proper tracking Negative values mean West and South 10 Anti shadowing Applies only to solar plants where many trackers are mounted close together in the East West line In the morning and in the evening even a small shadow from neighbor panels could dramatically reduce output power of the panel This effect appears when one cell inside serial chain is in shadow causing all cells in serial chain to fail with power Some panels have bypass diode Or tracker should move in opposite direction to eliminate any shadow And this way our tracker does Write panel width into panel width field and distance between trackers in E W line into panel spacing field If any of those two fields are 0 function is disabled 11 Night position A B Is the position in degrees where the tracker will park during the night This is between night mode and day mode time 12 Reference interval Motor actuator position needs to be sychonized with internal counters inside Nano electronic module This can be done manually trackers tab or automatically by setting reference interval value Meaning on how many days it wil
17. t change anything If you have your own tracker see Geometry document available on our web side Or contact our technical support If Geometry mode is 0 this axis is not in use Will not be controlled Geometry mode parameters are fixed by purchasing conditions Contact our sales team to add additional geometries or change 19 Coordinate mode Means which coordinate system astronomic equations are using General known is Azimuth Elevation system AE other less know is Polar Mount system PM Note In the case of using our tracker parameters are already set 20 Moving properties elevation hour angle polar elevation Each motor uses some moving range measuring impuses by hall incremental encoder Max range means maximum permited impulses at which value motor will stop Above motor will be hard stopped The same is for min range limit Relation between impulses and degrees slew drives or milimeters linear motors is defined by gear ratio Gear ratio is counted number of impulses by positioner per one degree or one milimeter Note In the case of using our tracker parameters are already set 21 U supply factor Is measuring calibration factor for voltage on monitoring tab We do not encourage you to change these values Sigma user manual_rev1 5 Trackers tab Bootloader version 1 007 Application version 1 124 Date 19 12 2011 10 00 SOLAR TRACKER SERVER WEB BASED You are l