2-Wire ECL-VIP200 User`s Manual V1.0.0 201509

image

Contents

1. 12 3 installation Debugging sins ccr e e n v eee eo un Oo D tm ated 13 3 1 WV EB Setup eb vn Mi 13 322 General COMME isis oruedidesteuis Diei bec toe desde COH 14 4 ctu mte eed Mu tU DR 16 0 5 16 4 1 1 Were RTT UT EROR 16 4 1 2 BESTE 17 4 1 3 Indoor MTIdBg BE op 17 4 1 4 NEtWOTK COMM M 19 4 1 5 rere cer ee eee eee meena 19 4 1 6 Bix ighutii i lcm E 20 22 21 4 2 1 21 4 2 2 22 4 3 Status Statistiese tee sate Dok 22 4 3 1 SUAS p M 22 4 4 LOBOUL as 22 5 Basic 55 23 MEME Bree REEL 23 52151 te OFC ONC 23 5 1 2 YS Cl RC 24 5153 po TH a 24 5
2. e E e 2 HT 3 9 EM e mm e ug o Figure 1 2 It monitors corresponding door region Light compensation will automatically turn on Compensation 4 during monitoring calling or connecting status if Light ae there is no enough light in environment User Nameplate Display username and other info Call Button Call center or VTH 1 2 3 Rear Panel CO Figure 1 3 Component Name Note Camera Angle l Adjust camera angle Adjustment Vandal proof When VTO if forced to leave wall it will alarm and Switch report to MGT center Connect to lock door sensor feedback and unlock User Port button Project Port Reserved for project staff use 1 3System Networking This chapter mainly introduces usage of digital VTO please read the following content and install the device according to your actual condition 1 3 1 One to One Scene Visitor press Call button to call residence as VTH or Center See Figure 1 4 Daor Sensor Electric Unlock Lock Lock Butten 2 pin Cable Figure 1 4 1 3 2 Group Call Scene When visitor press Call button on VTO multiple VTHs will ring at the same time User can call hang up and unlock on any of these VTHs Note VTH has 1 master VTH and up to 3 extension VTHs See Figure 1 5 xtension Extension Extension 2 pin Cable Figure 1 5 2 Install VTO 2 1 Direct Installat
3. Figure 3 1 13 3 2 General Config If you first use VTO you may need to operate according to the following steps otep 1 In Internet Explorer input IP address of the VTO and press Enter Note Default IP address of VTO is 192 168 1 110 Default username and password is admin admin After first login please change your password Step 2 In WEB interface select System Config gt Local Config set video format as WVGA as in Figure 3 2 Local Config A amp C Manager System Time Config Manager Video Format Device Type Villa Station Sensitivity of fill lightto open Version Info Figure 3 2 Step 3 In System Time tab click on Sync PC to make VTO time the same with PC Step 4 Select System Config gt Network Config set VTO IP Subnet Mask and Default Gateway See Figure 3 3 IP Address 10 15 6 141 subnet Mask 255 255 0 0 Default Gateway 10 15 0 1 Address Default Refresh Figure 3 3 14 Step 5 Optional If VTO connects to VIMS platform System Config gt LAN Config set Area No Section No Building No and etc These parameters must match settings on VTMS Client Please refer to Appendix 2 and See Figure 3 4 LAN Config Building Ma 101 6901 Group Call Figure 3 4 Name Type VTO ty Manufacturer dahu Position Communityl Unit 1 Net Address Sub Net Gate Way Net Port Switch Re
4. 2 Wire ECL VIP200 User s Manual V1 0 0 Table of Contents dare cae 1 1 LL UBSCOPMOGSOIS iode bd sedem ote e Mot 1 1 2 T 1 12221 1 1 2 2 Front Panel m TELE 2 1 2 3 EN 3 1 3 System 3 1 3 1 SCONE e 4 1 3 2 OUD Call SCC orate tet cae etter 4 2 ELO Eccc 5 25 BirecthnstallatioD a 5 2 1 1 req tees 5 2 1 2 DIMENSION cR 6 2 13 ristallatiot Sep 6 22 Embedded m 8 2 2 1 8 2 2 2 DIMENSION RET S 8 2 2 3 AStA UON SC e OO TNT 9 2 3 seda e circu 11 2 4 Electric Control Lock and Electromagnetic 11 2 4 1 m 11 2 4 2 Electromagnetic
5. System Config LAN Contig Local Config HT Building Mo 01 Building Unit No 1 Network Config gt gt gt Indoor Manager gt ccd VTO No 6901 Group Call gt User Manage Info Search MGT Centre IP Address 10 22 5 254 Register to the MGT Centre Status Statistics Logout MGT PortNo 12801 Call VTS Time To 23 gt Call VTS Or Not Warning The device needs reboot after modifing the config above Figure 5 3 25 Set Main VTH Step 1 On VTH screen press System Settings gt Project Settings input password default is 002236 to enter Project Settings interface Step 2 Press Product Info input Room No Local IP and etc as in Figure 5 4 Note Room No must match setting in VTH Short No In Figure 5 4 m Project Settings Room No 102 Master Local IP 172 5 105 m Network Subnet Mask 255 255 0 mw PC Info Gateway 172 5 1 MAC Default Version Back Figure 5 4 otep 3 Press Network input VTO IP Address See Figure 5 5 Project Settings Product Info Main VTO Name Main YTO Device Type YTO Middle No mm Info YTO IP Address 172 Default Network Port Enable Status gt Back OK Figure 5 5 26 Set Extension Step 1 On VTH screen press System Settings gt Project Settings input password default is 002236 to enter Project Settings interface Step 2 Press Product Info Pre
6. gt 192 168 1 108 0 Logout Figure 4 11 4 4Logout Here you can reboot device or logout Click on logout to log out the system and it returns to login page 22 5 Basic Function Introduction 5 1 Call Function 5 1 1 Call Manager Center Check Register to the MGT Center you can touch the Call button to call manager center Now VTO can only call MGT Center cannot call VTH Manager center s time can be set on management platform or villa VTO s web end Once manager center picks up the call you can perform a visual bidirectional talk with the manager center You can touch the button on VTO to end call at any time otep 1 otep 2 otep 3 otep 4 otep 5 otep 6 According to VTO configured for the center fill in building no building unit no and VTO no In LAN Config check register to the MGT center as in Figure 5 1 Fill in MGT center IP address and MGT port no Set call VTS time Within this period VTO can only call the center Check Call VTS or not Confirm all config and click on OK Enter Logout gt Reboot Devices to manually reboot the device Local Config Building a1 Indoor Manager Building Unit Mo 1 Video Set 6901 Group Call User Manage gt gt gt gt Network Config gt gt Info Search Status Statistics Logout 23 MGT Centre IP Address 10 22 5 254 Register to the MGT Centre 12801 CallVTS Time 00
7. in the same segment with VTO See Appendix 3 2 Local Area Connection Properties Internet Protocol TCP7IP Properties 2 General em General Connect uzing can P settings assigned automatically if your network supports this capability CItherwise you need to ask your network administrator for 88 Broadcom Netstreme Gigabit the appropriate IP settings This connection uses the following items Obtain an IP address automatically E Client For Microsoft Networks gt Use the following IP address and Printer Sharing for Microsoft Ip ads 10 15 dal qos Packet Scheduler i Internet Protocol Subnet mask 255 255 Default gateway 10 15 Description Transmission Control Protocal Intermet Protocol 2 Use the following DNS server addresses wide area network protocol that provides comm across diverse interconnected networks Preferred ONS server 2 8l Alternate ONS server 8 Hl Show icon in notification area when connected Notify me when this connection has limited or ry Appendix 3 2 32 Step 3 After complete modification select Start gt Run input cmd click on OK Enter command interface input ping IP of the VTO If it obtains communication data then VTO and the PC are connected See Appendix 3 3 CEWINDOWS s ystem3 Microsoft Windows Version 5 1 2600 CC Copyright 1985 26061 Microsoft Co
8. to GND of VTO user port 9 oee Figure 2 9 11 mmm 4858 OUT UMLOCK FEED GND 2 BUTTON Figure 2 9 2 4 2 Electromagnetic Lock When VTO connects to electromagnetic lock it means that the positive end of electromagnetic lock connects to NC of VTO user port 11 while its negative end connects to COM of VTO user port 12 When VTO connects to door sensor in electromagnetic lock one end of door sensor connects to FEEDBACK of VTO user port 8 while the other end connects to GND of VTO user port 9 See Figure 2 10 Figure 2 10 12 3 Installation Debugging Warning Before debugging the staff shall be familiar with device s installation wiring and usage Before debugging check wiring for short or open circuit When staff find each circuit is normal plug the device to power After debugging clear the site 3 1 WEB Setup If you first use VTO you may need to operate according to the following steps otep 1 First make sure your PC and the VTO are well connected and follow steps below to login WEB interface otep 2 In Internet Explorer input IP address of the VTO and press Enter System shows Figure 3 1 Step 3 Input Username and Password otep 4 Click on Login Note Default IP address of VTO is 192 168 1 110 Default username and password is admin admin After first login please change your password IP VDP Door Station Web Server V1 0
9. 2 HH 27 S39 UNockEUNCUOM 27 SA Compensauorn 28 isn vain la 28 SF ONME 28 6 29 Appendix 1 Technical 5 5 30 Appendix 2 Technical Speclficatiofis uo et oe e 31 Apperndix2 1 Cable Specification uie d e etu oen 31 Appendix 2 2 Power Extension Line 5 31 Appendix 2 3 Embedded BOX sii ile Venir test s opt ees 31 Appendix 3 VIM S roen UC 32 APpendiIxX A VIMS GIGI rU 34 Appendix 4 1 Config Network 6 nennen nennen nennen rne nenas 34 Abppendbcd 2 Create Organization iS e Du ME e Ud s cas paio DM 36 Important Safeguards and Warnings Please read the following safeguards and warnings carefully before using the product in order to avoid damages and losses Note Do not expose the device to lampblack steam or dust Otherwise it may cause fire or electric shock Do not install the device at position exposed to sunlight or in high temperature Temperature rise in device may cause fire Do n
10. 29 9mmx32 2mmxx140mm LxWxH Weight 0 8kg 30 Appendix 2 Technical Specifications Appendix 2 1 Cable Specification The wiring length between VTO and VTH is Ly so reasonable specification of wiring is Cable Specification 0 lt 1 lt 50 50 lt Lys100m UTP Cat5e Cat6 10 ohm 100m Optional Optional UTP Cat5e Cat6 18 8 ohm 100m Optional Not optional Note Please do not let Ly be over 100m Appendix 2 2 Power Extension Line Specification The wiring length between VTO and adaptor is Lc so reasonable specification of extnsion Extension Line Specification O Lcs30m 30 Lces100m 20AWG Optional Not optional line IS 18AWG Optional Optional 17AWG Optional Optional Note Before plugging extension line to power make sure its positive and negative end are correctly wired Appendix 2 3 Embedded Box VTO Model Embedded Box ECL VIP200 Case 126 115 31 Appendix 3 VTMS Check Installation Environment This manual makes Window XP as example to introduce how to modify IP of PC inorder to connect VTMS and monitoirng system Step 1 Select Start Control Panel gt Network Connection gt Local Area Connection right click on Local Area Connection icem select Properties see Appendix 3 1 Grea Connection Connected F iroadcom Me Disable Status Repair Bridge Connections Create Shorkcuk Properties Appendix 3 1 Step 2 View and modify IP address make it
11. Figure 4 7 Fill in user info Add User bj Username Password Contirm Remark Figure 4 7 20 e Modify User In User Manage interface click on system pops up Modify User interface Check Change Password and change password and remark see Figure 4 8 Modify User New Password Confirm Remark admin s account Figure 4 8 e Delete User In User Manage interface click on gt to delete user 4 2 Info Search 4 2 1 Call History Here you can view call history of VTO in Call History interface It can save up to 1024 items System Config VTO Call History Info Search gt Call Type Room No Begin Time Talk Time m End State gt Alarm Record Status Statistics Logout Figure 4 9 21 4 2 2 Alarm Record You can search VTO alarm record on Alarm Record interface with storage up to 1024 items See Figure 4 10 System Config Alarm Record Info Search gt Call History Event State Channel Begin Time gt Status Statistics Logout Figure 4 10 4 3 Status Statistics 4 3 1 VTH Status Here you can view connection status of VTH e Status Offline VTO and VTH are not connected you cannot call monitor talk or etc Online VTO and VTH are connected you can call monitor talk and etc MON Unmon is not monitoring VTH is monitoring oee Figure 4 11 System Config VTH Status Info Search Status Statistics Reg Time
12. cieve Notice Comments Figure 3 5 Note When you configue one to multiple scene different VTOs shall have different VTO no and same building no and unit no in order to form a proper network 15 4 Web Config This chapter introduces VTO WEB interface and its parameters and hot to configure them 4 1 System Config 4 1 1 Local Config 4 1 1 1 Local Config In Local Config interface you can view VTO model version info and etc System Config Local Config A amp C Manager System Time Config Manager gt m 1 LAN Config Video Format WVGA v Device Type Villa Station v indoor Manager Frame Rate 25 v RebootDate Tuesday gt Network Config gt Video Set Sensitivity of fill lightto open 60 Version Info gt User Manage Info Search Default Refresh OK Status Statistics Logout Figure 4 1 Video Format Set video format that collected by the camera including WVGA and D1 WVGA resolution is 800x480 D1 resolution is 704 576 Display device type NTSC 30 fps PAL 25 fps Reboot Date On the set date device will automatically reboot sensitivity of fill Set threshold of light Display device version info Only restore current Local Config page to default settings 16 4 1 1 2 A amp C Manager System Config Local Config A amp C Manager System Time Config Manager LAN Config Unlock Responding Interval 15 Door Sensor Check Time 30 Check Doo
13. ddress See Appendix 4 3 SN 330103000000800053 Mame s VTS Type VTS Net Address Met Port Comments MEINE Appendix 4 3 otep 5 Click on Save Input project password default project password is 123 Step 6 Re login VTMS you can see is successfully configured as in Appendix 4 4 VTS successfully connected Appendix 4 4 35 Appendix 4 2 Create Organization First you must build up environmrnt and set VTMS server please refer to Appendix 3 This chapter takes example of a residence with 10 buildings and 2 units Create Residence Organization Step 1 In VTMS main interface select Organization click on Batch Add System pops up Batch Add box see Appendix 4 5 a Device Status 3 Device MGR Contract All Expand All Name only Refresh Current Node Zone SN 26 Address Note Add Modify 2 Batch Add J Batch Delete Upper SN Community 01 Upper Name Community 1 Batch parameter total of 10 building s each with 2 HH unit s e Cancel Appendix 4 5 Step 2 Click on OK to save The created organization is as in Appendix 4 6 gt Home Device Status EX Device MGR Contract All Expand All Name only Refresh Current Node Organization E Building 1 i 2 Address Community 1 36 Building 2 Zone SN Community 01 i 8 Building 3 Note Q Add Modify D Batch Add Ba
14. ead tail 4 machine screws galvanizing white Chart 2 2 Note M3x6 or M3x8 either is OK 2 2 2 Dimension Before you install the device please make sure you know the dimension of device and select appropriate installation method See Figure 2 4 15 Figure 2 4 2 2 3 Installation Step otep 1 otep 2 otep 3 Dig a hole on wall its dimension is 117 128 80 mm See Figure 2 5 Embed metal bracket into wall until its four peaks lean against the wall See Figure 2 6 Align the device on metal bracket according to screw hole At 2 spots fasten screws M3x8 Cross recessed countersunk head tail machine screws galvanizing white and fix device on metal bracket See Figure 2 7 co CU L LO a T Figure 2 5 Figure 2 7 2 3Wiring oee Figure 2 8 LILILILILILI viviviviviviwiviviviviei Figure 2 8 Component Note Name Power supply connect to lock door sensor and User Port unlock button m Project Port Reserved for project staff use 2 4Electric Control Lock and Electromagnetic Lock 2 4 1 Electric Control Lock When VTO connects to electric control lock it means that the positive end of electronic control lock connects to NO of VTO user port 10 while its negative end connects to COM of VTO user port 12 When VTO connects to unlock button one end of unlock button connects to UNLOCK BUTTON of VTO user port 7 while the other end connects
15. function Restore VTH Info If VTH info is mistakenly changed you can restore VTH info with this function Note Every half hour VTO automatically saves card and VTH info in the system If you want to restore card and or VTH info you must restore within half hour after your last operation that change these info 28 29 FAQ Q pressed Call button and the indicator turned on but the VTO did not start a call A Please check your operation process Q How to end a call when am calling A Please press button on VTO and there will be sound from the device Q The device could not boot up and there was no sound or light A Please check if power supply is well plugged Q My call did not go though A It is network connection error please check the cables of the device and its extension Q have other problems not included above A Please contact technical staffs for assistance Appendix 1 Technical Specifications Embedded micro controller oystem Embedded Linux os Video Compression H 264 Video Standard Input Sensor 1 3 Megapixel CMOS HD camera Night Vision Support Output Built in speaker Omnidirectional Mic Audio Support bidirectional talk Door Lock Mode S rt tional Status Check UPPOR IARU Ethernet 10M 100Mbps self fit Network Network TCP IP Protocol Standby lt 1W working lt 7W Working 30 60 Temperature General Relative 1096 90 RH Humidity Dimension 1
16. ion 2 1 1 Screw Before installing VTH please check screws on accessory bag according to the following specifications and install by following this guide Component Name Illustration Quantity M3x6 Hex slot pan head tail machine screws E galvanizing white M3x8 Cross recessed countersunk head tail machine screws galvanizing white ST3x18 Cross recessed countersunk head x 4 tail tapping screws galvanizing white 4 Chart 2 1 Note M3x6 or M3x8 either is OK 2 1 2 Dimension Before you install the device please make sure you know the dimension of device and select appropriate installation method See Figure 2 1 Figure 2 1 2 1 3 Installation Step Step 1 Install metal bracket into the groove on wall At spot 1 fasten screw ST3x18 Cross recessed countersunk head tail tapping screws galvanizing white and fix metal bracket on wall See Figure 2 2 otep 2 Align the device on metal bracket according to screw hole At spot 2 fasten screw M3x8 Cross recessed countersunk head tail machine screws galvanizing white and fix device on metal bracket See Figure 2 3 2 2Embedded in Wall 2 2 1 Screw Before installing VTH please check screws on accessory bag according to the following specifications and install by following this guide Component Illustration Quantity M3x6 Hex slot pan head tail machine am 4 screws galvanizing white M3x8 Cross recessed countersunk h
17. ot expose the device to humid environment Otherwise it may cause fire The device must be installed on solid and flat surface in order to guarantee safety under load and earthquake Otherwise it may cause device to fall off or turnover Do not place the device on carpet or quilt Do not block air vent of the device or ventilation around the device Otherwise temperature in device will rise and may cause fire Do not place any object on the device Do not disassemble the device without professional instruction Warning Please use battery properly to avoid fire explosion and other dangers Please replace used battery with battery of the same type Do not use power line other than the one specified Please use it properly Otherwise it may cause fire or electric shock Special Announcement This manual is for reference only All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website for more information 1 Product Overview 1 1List of Models key 1 2Structure 1 2 1 Dimension Before you install the device please make sure you know the dimension of device and select appropriate installation method See Figure 1 1 mm 129mm 32 2 mm TEM 140mm Figure 1 1 1 2 2 Front Panel
18. r Sensor Signal Before Lock Unlock Period 2 Network Config Video Set User Manage Default Refresh OK gt gt gt Indoor Manager gt gt gt Figure 4 2 Unlock Responding The interval between current unlock and next one Interval unit is second Unlock Period Period door remains unlocked unit is second Door Sensor Check When only use door sensor check Check Door Time sensor Signal Before Lock Set Door Sensor Check Check Door Sensor Time to enable it Signal Before Lock When door remains unlocked over set door sensor check time it alarms 4 1 1 3 System Time Here you can set date format time format and input system date and time You can also click on Sync PC to synchronize system time with PC time 4 1 2 LAN Config Here you can register VTO to center and set how to call center Please refer to Ch 5 1 1 4 1 3 Indoor Manager In Indoor Manager interface you can add VTH digital indoor station view VTH info and delete VTH System Config Indoor Manager gt Local Config Digital Indoor Station Manager FamilyName Nick Name IP Address 192 168 1 108 gt LAN Config gt gt Network Config gt Video Set gt User Manage Figure 4 3 17 Add VTH In Indoor Manager interface click on Add The system pops up a window as in Figure 4 4 FirstName Mick Name VTH short No IP Address Figure 4 4 Fill in VTH info as user s name VTH
19. rp C Documents and Settings 10881 gt 18 22 5 189 LU Appendix 3 3 Enable VTMS The following mainly introduces how to config VIMS for you to login VTO and use VTMS otep 1 Install VTMS on PC L Step 2 Double click on _ click on Start service and VTMS will boot up Stop service Create Threads Process ID Parent ID Priority 0 31 11 18 2013 03 00 53 134 30 444 548 8 11 18 2013 09 01 01 169 3016 816 8 PMU exe 11 18 2013 03 01 21 ggi 19 3660 816 8 Appendix 3 4 33 Appendix 4 VTMS Client This following mainly introducts how to config VTMS Client Appendix 4 1 Config Network Address otep 1 Install VTMS Client on PC Step 2 Double click on VTHS exe in pop up box input username password IP address port and etc Click on Login See Appendix 4 1 Note Default username and password is admin and 123 respectively After first successful login please change password Vision Telephone Manage System name admin pwd ET ip 172 5 1 107 8787 auto login save pwd Appendix 4 1 otep 3 In main interface click on Device MGR See Appendix 4 2 Organization Device MGR Appendix 4 2 34 otep 4 Double click on VTS parameter collumn sustem pops up Edit device box input PC s IP a
20. short no and IP address Note VTH short no consists of four digits the first two digits can be within 01 99 the last two digits can be within 01 16 Note Parameters with are mandatory 18 4 1 4 Network Config Here you can set VTO IP address Subnet Mask and Default Gateway After you have modified IP address Web page will reboot and go to the new IP address web page See Figure 4 5 system Config Network Config FTP Contig Local Config LAN Config Address 10 15 6 141 Indoor Manager SubnethMask 255 255 0 0 gt gt gt gt gt Video Set Default Gateway 10 15 0 1 gt User Manage Info Search MAC Address Status Statistics Logout Figure 4 5 4 1 5 Video Set You can set video effect and volume in Video Set interface See Figure 4 6 System Config Video Set gt Local Config gt LAN Config gt Indoor Manager Brightness 0 50 gt Network Config Coni 50 gt Hue 50 gt User Manage Info Search Saturation 50 Status Statistics Logout GainAuto 90 SceneMode Automatic v Day Night Mode Colorful BackLight Mode Disabled v Mirror On off Default Flip VTO Mic Volume 90 VTO Beep Volume 80 Figure 4 6 19 4 1 6 User Manage Only when you login as admin you can add modify delete and view user info in User Manage interface e Add User In User Manage interface click on Add User system pops up
21. ss Master Master icon becomes Extention icon otep 3 Set Room No i e 1101 1 input IP Address Subnet Mask and Gateway Step 4 In Master IP input IP of the main VTH After competion extension will automatically sync with main VTH info configured by user See Figure 5 6 m 8 Project Settings A Room No 102 1 Extension Productinfo lt Local IP 172 106 EI Nenvork Subnet Mask 255 0 Info Gateway 172 1 MAC Default Version Back Master IP 172 Figure 5 6 5 2 Monitor Both VTS and VTH are able to monitor this VTO by enabling the camera to capture local circumstance 5 3Unlock Function Unlock by Center When center is called calling or monitoring center can remotely unlock door VTO will return to standby interface after call ends or countdown stops Unlock by VTH When VTH is called calling or monitoring VTH can remotely unlock door VTO will return to standby interface after call ends or countdown stops 27 5 4 Compensation of Light In dark environment or at night the VTO adopts auto photoreception technology which achieves light compensation in connecting status 5 5Vandal Proof There is one channel of vandal proof which will generate alarm sound and report to the manager center once VTO is forced to leave the wall 5 6Restore Backup Restore Card Info If you encounter abnormality with card info or accidently restore default settings you can restore card info with this
22. tch Delete Appendix 4 6 36 e Add VTO Step 1 In VIMS main interface select Device MGR click on Add system pops up Batch Add box Step 2 Fill in info according to your actual condition and click on Save See Appendix 4 T SN Name Type Manufacturer Position Net Address Sub Net Gate Way Net Port Switch Recieve Notice Comments Type amp location can t be changed after saving Appendix 4 7 37 Add VTH Step 1 In VTMS main interface select Device MGR click on Batch Add system pops up Batch Add box Step 2 Fill in info according to your actual condition and click on Save See Appendix 4 8 Device Type VTH type Manufacturer Community Building Unit Floors per unit House per floor Appendix 4 8 Note 38 This manual is for reference only Slight difference may be found in user interface All the designs and software here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information
23. w 00 v 23 w 59 0 Or Net Warming The device needs reboot after modifina the config above Default Refresh Figure 5 1 5 1 2 Call User Press Call button under standby status and the VTO will call user User may monitor VTO from VTH On VTH press Unlock button to unlock door e When VTH picks up you can start talk with the VTH If no one answers the call then the call will end automatically and device returns to standby status 5 1 3 Group Call Group call is mainly used for one VTO Press Call button on VTO to call multiple VTH at the same time VTH consists of master VTH and extension VTH A system can only have a max of 1 master VTH and 5 extension VTHs Please refer to VTO2000A Series Installation Guide V 1 0 0 oet VIO Step 1 Select System Config gt Indoor Station Manager system shows Indoor Station interface Step 2 In Indoor Station Manager interface click on to delete default VTH Step 3 Click on Add input VTH Short No IP Address optional to add a VTH See Figure 5 2 Note In Indoor Station interface you only need to add main VTH and you do not need to add extension 24 Mick Mame VTH Short No IP Address Figure 5 2 Note Paramete with are mandantory to be set Step 4 In LAN Config interface check Group Call and click on OK See Figure 5 3 otep 5 After config is complete enter Logout interface to reboot VTO