1. exceed 600V above earth ground in category II installations i e When the value scale to be measured is unknown i beforehand set the range selector at the highest 1 e position 1 Before rotating the range selector to change functions e disconnect test leads from the circuit under test When carrying out measurements on TV or switching E power circuits always remember that there may be high amplitude voltages pulses at test points which can e damage the meter Always is careful when working with voltages above 60V dc or 30V ac rms Keep fingers behind the probe barriers i e while measuring 1 Before attempting to insert transistors for testing always 1 be sure that test leads have been disconnected from any 1 e measurement circuits 1 Components should not be connected to the hFE socket when making voltage measurements with e test leads Never perform resistance measurements on live circuits I I I I I I I I I I I I I GENERAL DESCRIPTION The meter is a handheld 31 2 digital multimeter for measuring DC and AC voltage DC current Resistance Diode Transistor Temperature and Continuity Test with battery operated FRONT PANEL FRONT PANEL DESCRIPTION Display 3 1 2 digit 7 segment 15mm high LCD Rotary switch This switch is used to select functions and desired ranges as well as to turn on off the meter Hold button When this button is pushed the disp
2. jack and the black lead to the COM jack 2 Set rotary switch at desired DCV position If the voltage to be measured is not known beforehand set range switch at the highest range position and then reduce it until satisfactory resolution is obtained 3 Connect test leads across the source or load being measured 4 Read voltage value on the LCD display along with the polarity of the red lead connection DC CURRENT MEASUREMENT il Connect the red test lead to the V O mA jack and the black test lead to COM jack For measurements between 200mA and 10A remove red lead to 10A 2 jack 3 Set the rotary switch at desired DCA position Open the circuit in which the current is to be measured 4 and connect test leads in series with the circuit Read current value on LCD display along with the polarity of red lead connection AC VOLTAGE MEASUREMENT 1 Connect the red test lead to V O mA jack and the black test lead to the COM jack 2 Setthe rotary switch at desired ACV position 3 Connect test leads across the source or load being measured 4 Read voltage value on the LCD display DIODE TEST 1 Connect the red test lead to V O mA jack and the black test lead to the COM jack The polarity of red lead is positive Set the rotary switch at BF position Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode The approx forward v
3. K type thermocouple into I the V O mA jack and the black lead of K type 1 I I Li I I I I l I I I I Li Li I I I I thermocouple into the COM jack 3 Read temperature value on the LCD display A WARNING To avoid electric shock be sure the thermocouple has been removed before changing to another function measurement BATTERY amp FUSE REPLACEMENT If 73 appears on display it indicates that the battery should be replaced Fuse rarely need replacement and blow almost always as a result of operator s error To replace battery amp fuse 200mA 250V remove the 2 screws in the bottom of the case Simply remove the old and replace 8 NwARNING Before attempting to open the case always be sure that test leads have been disconnected from measurement circuits Close case and tighten screws completely before using the meter to avoid electrical shock hazard ACCESSORIES Operator s instruction manual e Set of test leads e Gift box e 9 volt battery NEDA 1604 6F22 type e K type thermocouple e Holster option HYS004610 A1
4. 200mA 100A 1 5 of rdg 2 digits Overload Protection F 200mA 250V fuse 10A range unfused AC VOLTAGE 11 2 of rdg 10 digits 31 2 of rdg 10 digits Overload Protection 600V dc or rms ac for all ranges Frequency range 40Hz to 400Hz Response Average responding calibrated in rms of a sine wave DIODE amp CONTINUITY Description If continuity exists about less than 1 5kQ built in buzzer will sound Show the approx forward voltage drop of the diode Overload Protection 250V dc or rms ac I I I I Li I I I I Li l I I I I l I I I I Li i 3 of rdg 2 digits I L l I I I I Li I I I I I I I I I l I I TRANSISTOR hFE TEST 0 1000 Range TestRange Test Current Test Voltage NPN 8 PNP 0 1000 lb 104A RESISTANCE 0 8 of rdg 2 digits 0 8 of rdg 2 digits 0 8 of rdg 2 digits 1 0 of rdg 2 digits Maximum Open Circuit Voltage 3 2V Overload Protection 250V dc or rms ac for all ranges TEMPERATURE Range Resolution Test Range Accuracy 20 C to OC 10 of rdg 2digits 19 1C 0 C to 400 C 1 0 of rdg 3digits 400 C to 1000 C 12 096 of rdg TEMPERATURE Range Resolution Test Range Accuracy 4 F to 32 F 10 of rdg 2digits F 1 F 32 F to 752 F 1 0 of rdg 3digits 752 F to 1832 F 2 0 of rdg OPERATING INSTRUCTIONS DC VOLTAGE MEASUREMENT 1 Connect the red test lead to the V O mA
5. OPERATOR S INSTRUCTION MANUAL SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category CAT II and pollution 2 Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition Full compliance with safety standards can be guaranteed only with test leads supplied If necessary they must be replaced with the type specified in this manual SAFETY SYMBOLS A Important safety information refer to the operating manual AN Dangerous voltage may be present l Earth ground 1 Double insulation Protection class II Fuse must be replaced with rating specified in the manual MAINTENANCE e Before opening the case always disconnect test leads from all energized circuits e For continue protection against fire replace fuse only with the specified voltage and current ratings F 200mA 250V Quick Acting e Never use the meter unless the back cover is in place and fastened completely e Do not use abrasives or solvents on the meter To clean it using a damp cloth and mild detergent only DURING USE I I I e Never exceed the protection limit values indicated in specifications for each range of measurement e When the meter is linked to measurement circuit do not touch unused terminals e Never use the meter to measure voltages that might
6. lay will keep the last reading and Il symbol will appear on the LCD until pushing it again 10A jack Plug in connector for red test lead for 10A measurement COM jack Plug in connector for black negative test lead or plug in the black plug with k type thermocouple VOMA jack Plug in connector for red positive test lead for voltage resistance and current except 10A measurements or plug in the red plug with k type thermocouple SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18 to 28 C 64 F to 82 F with relative humidity to 80 GENERAL Maximum voltage between CAT II 600V terminals and earth ground Fuse protection F 200mA 250V Power 9V battery NEDA 1604 or 6F22 Display LCD 1999 counts updates 2 3 sec Measuring method Dual slope integration A D converter Overrange Indication Only figure 1 on the display Polarity indication displayed for negative polarity Operating Environment 0 to 40 C Storage temperature 10C to 50 Low battery indication 23 appears on the display Size 138mm x 69mm x 31mm Weight Approx 170g DC VOLTAGE 200mV 1004V 0 5 of rdg 2 digits 0 5 of rdg 2 digits 0 5 of rdg 2 digits 20 5 of rdg 2 digits 10 8 of rdg 2 digits Overload Protection 250V rms For 200mV range and 600V dc or rms ac for other ranges DC CURRENT 1 of rdg 2 digits 1 of rdg 2 digits
7. oltage drop of the diode will be displayed If the connection is reversed only figure 1 will be shown TRANSISTOR TEST 1 2 Set the rotary switch at hFE position Determine whether the transistor under testing is NPN or PNP and locate the emitter base and collector leads Insert the leads into proper holes of the hFE socket on the front panel Read the approximate hFE value at the test condition of base current 104 A and Vce 3V RESISTANCE MEASUREMENT 1 Connect the red test lead to V O mA jack and black test lead to the COM jack The polarity of red lead is positive 2 Set the rotary switch at desired O range position 3 Connect test leads across the resistor to be measured and read LCD display 4 f the resistance being measured is connected to a circuit turn off power and discharge all capacitors before applying test probes I I Li L I I I I l I I I I AUDIBLE CONTINUITY TEST 1 Connect red test lead to V Q mA black test lead to COM 2 Set range switch to position i 3 Connect test leads to two points of circuit to be tested If i continuity exists built in buzzer will sound 1 MEASURING TEMPERATURE If the meter is the C function set the rotary switch at C Position If it is the F function set the rotary switch at F Position The LCD display will show the current 1 environment temperature 1 2 Connect the red lead of

Download Pdf Manuals

image

Related Search

OPERATOR`S operators operators union operators in python operators in java operators wiki operators license operators game operators in c++ operators r6 operators in sql operators engineers union operator\u0027s manual operators meaning operators union near me operators siege operators club dallas operators union apprenticeship operators in javascript operators unlimited operators 150 operators syndrome operators c# operators club operators demo operators local 150

Related Contents

CSCI321 – AlphaLogic – Project Plan Session 1  Water Logger Housing Manual (Part # HOUSING-U2x)  Sony DVP-FX720 Portable DVD Player  FRITZ!Box 7490    AD-5617/AD-5617WP 放射温度計 取扱説明書 保証    Compalarm G+81 - Contrel elettronica  Yazoo/Kees YTBS-D265 User's Manual  モバイル充電バッテリーMPC-C5200 取扱説明書ダウンロード[PDF 1.28  