Home

3. Logging in to the Web Browser for User

image

Contents

1. Note The web page will be displayed in the same language as the operating system on the PC The web page can be displayed in other languages by entering the web page address as follows Chinese http IP address of each AE 200 AE 50 or EW 50 zh index html English http IP address of each AE 200 AE 50 or EW 50 en index html French http IP address of each AE 200 AE 50 or EW 50 fr index html German http IP address of each AE 200 AE 50 or EW 50 de index html Italian http IP address of each AE 200 AE 50 or EW 50 it index html Japanese http IP address of each AE 200 AE 50 or EW 50 ja index html Portuguese http IP address of each AE 200 AE 50 or EW 50 pt index html Russian http IP address of each AE 200 AE 50 or EW 50 ru index html Spanish http IP address of each AE 200 AE 50 or EW 50 es index html Note You can add the web page address to your Favorites on the login screen for easy access in the future 2 Enter the user name and the password in the login screen and click Login A Condition List screen will appear which shows the operation conditions of groups Note Consult the building manager for your user name and password WT07140X02 1 0 Encrypting the communication data and logging in to the Web browser HTTPS connection AE 200 AE 50 EW 50 can encrypt communication data using HTTPS SSL When connecting the AE 200 AE 50 EW 50 to the LAN that is accessible to the ge
2. 7 Add all AE 200 AE 50 EW 50 to the list in the same manner and a General Update Java Security Advanced click OK Security level for applications not on the Exception Site list Very High Only Java applications identified by a certificate from a trusted authority are allowed to run and only if the certificate can be verified as not revoked High Java applications identified by a certificate from a trusted authority are allowed to run even if the revocation status of the certificate cannot be verified Exception Site List Applications launched from the sites listed below will be allowed to run after the appropriate t security prompts rA 92 168 1 1 ttp 192 168 1211 F ttp 192 168 1212 Edit Site List l Restore Security Prompts Manage Certificates Apply 8 If aPC with 32 bit OS is used after completing the settings close all Internet Explorer windows and access the Web page again to make sure the appropriate window will appear If a PC with 64 bit OS is used go to step 9 below 9 Click My Computer gt Local Disk C gt Program Files x86 1 gt Java gt jre The asterisk indicates a version number i e jre1 80_25 gt bin to open the bin folder 1 Ifa PC with 64 bit OS is used both Program Files and Program Files x86 folders will appear Make sure to select Program Files x86 10 Double click t
3. Automatic configuration may override manual settings To ensure the use of manual settings disable automatic configuration Automatically detect settings Use automatic configuration script Address Proxy server fy Use a proxy server for your LAN These settings will not apply to dial up or VPN connections Address 192 168 1 254 Port 8080 6 In the Proxy Settings window enter the AE 200 AE 50 EW 50 s IP address e g 192 168 1 1 in the Exceptions field Then keep E Type Proxy address to use clicking OK or Close to close all windows SE e SIHA Si 192 168 1 254 3 8080 If connecting multiple AE 200 AE 50 EW 50 units enter their eo es B080 addresses e g 192 168 1 1 192 168 1 2 It is also possible to use ds bL an asterisk as a wildcard e g 192 168 1 Be ee as Yee ae Exceptions Do not use proxy server for addresses beginning with 192 168 1 1 A Use semicolons to separate entries x ce WT07140X02 7 2 3 Java settings 2 3 1 How to register exception site list 1 Click Control Panel gt Javal Note If Category is selected in the top right corner next to View by change it to Large icons or Small icons 2 Java Control Panel will open Click the Security tab 3 The security setting window will open Click the Edit Site List button 4 The Exception Site List dialog will appear Click
4. Cancel D While fles from the Internet can be useful this file type can P potentially harm your computer Ifyou do not trust the source do Ww not open or save this software What s the risk oe i te General Details Certification Path A Certificate Information This certificate is intended for the following purpose s Ensures the identity of a remote computer All issuance policies Issued to Mitsubishi Electric CA 08C64 215 Issued by Mitsubishi Electric CA 08C64 215 Valid from 2014 04 01 to 2051 01 01 Install Certificate Issuer Statement Learn more about certificates 5 A Certificate Import Wizard window will appear Click Next Welcome to the Certificate Import Wizard This wizard helps you copy certificates certificate trust lists and certificate revocation lists from your disk to a certificate store A certificate which is issued by a certification authority is a confirmation of your identity and contains information used to protect data or to establish secure network connections A certificate store is the system area where certificates are kept To continue click Next aa a lt Back 6 Choose Place all certificates in the following store and click the Certificate Import Wizard Certificate Store Browse button Certificate stores are system areas where certificates are kept Select Trusted Root Certification Auth
5. 40 0 C 45 0 C di t th kl Group name obby AMIGAS TIE WESTY lt Hot Representative Temp Outdoor Temp Brine Temp Inlet Temp Outlet Temp schedule that IS currently 60 0 C 59 0 C 7 0 0 0 50 0 C 55 0 C HWHP CAHV CRHV unit effective group icons f Anti F Representative Temp Outdoor Temp Brine Temp Inlet Temp Outlet Temp i G 24 0 C 7 0 20 0 C 25 0 C The icons indicate the F igs obpy ope ration conditions of W ECO Representative Temp Outdoor Temp Brine Temp Inlet Temp Outlet Temp Fan mode Temperature groups 34 0 70 C 3 0 C 30 0 C 35 0 C Click the icon to switch to K the operation screen Operation mode Set temperature Click Air conditioners to display the operation conditions of air conditioning unit groups Air conditioners HWHP LOSSNAY unit groups Air To Water PWFY unit groups and general equipment groups and click HWHP to display the operation conditions of HWHP CAHV CRHV unit groups Update Click to show the most recent operation conditions Batch Operations Click to operate the units in all HWHP CAHV CRHV unit groups at once HWHP CAHV CRHV unit Each group icon indicates the operation condition of the group Clicking the icon will bring group icons up the operation screen The name of the group will appear Operation mode The operation mode of the group will appear The set temperature of the group will appear Set temperatu
6. LW Sticky Notes a Default Programs Snipping Tool XQ Help and Support gt All Programs een Ey Change settii Shut down 2 Click Network and Sharing Center gt Local Area Setting In the Local Area Connection Status window click Properties Sent A Received E Bytes 28 418 1 084 650 E eroperties _ psable Diagnose _ 3 Click Internet Protocol Version 4 TCP IPv4 to select it and click Gr Local Area Connacton uneries Properties Connect using This connection uses the following items V 0M Client for Microsoft Networks M QoS Packet Scheduler M J File and Printer Sharing for Microsoft Networks 4 Intemet Protocol Version 6 TCP IPv6 P Intemet Protocol Version 4 TCP IPv4 Link Layer Topology Discovery Mapper I O Driver amp Link Layer Topology Discovery Responder WT07140X02 3 4 In the Internet Protocol Version 4 TCP IPv4 Properties window Internet Protocol Version 4 TCP IPv4 Properties check the radio button next to Use the following IP address Enter the PC s IP address e g 192 168 1 101 in the IP address te apbay Chere you eed W ask your network ennai field and enter the subnet mask 255 255 255 0 unless otherwise PES specified in the Subnet mask field Use the folowing IP address IP address 192 168 1 101 In the Default gateway field enter the gateway address as necessary Note Consult the
7. MITSUBISHI ELECTRIC Air Conditioning Control System C Centralized Controller AE 200A AE 50A EW 50A AE 200E AE 50E EW 50E Instruction Book Web Browser for User Contents T SEO CE CUO Pereo E A E E E 2 1 1 Terms Used in This Manual ccccccccseeeceeeeeeeeeeeeeseeeeaeeeseees 2 1 2 PC Requirements aiccaceoecdstecessdadecsadcacecstinddentnsddlanttcaitecstectienatadle 2 2 Setting the Operating Environment ccccscceeeeeeeeeees 3 2 1 Setting the IP Address of the PC ccecccccseeeeceeseeesseseeeeeeees 3 2 2 Setting the Web BrowSel ccccccsssceccsseeeceeeseecceeseesseesessaaes 5 2 3 Java SOETLINGS ccccecccceeeeeceeeeceeeeeseeeeseeeeeseueeseeeeesaueesaeeeeseneenaaees 8 3 Logging in to the Web Browser for USET ccceeeeeeee 10 4 Monitor Operation ccccccceeceseeeseeeeeeeeeeeeeeeeeeeeeeaeeeeeees 13 dl Condition Be are ene ene ete 13 Before using the controller please read this Instruction Book carefully to ensure proper operation Retain this manual for future reference 1 Introduction This Instruction Book explains how to monitor and operate the units connected to the AE 200A AE 50A EW 50A and AE 200E AE 50E EW 50E using a Web browser 1 1 Terms Used in This Manual Centralized Controller AE 200A AE 200E is referred to as AE 200 Centralized Controller AE 50A AE 50E is referred to as AE 50 Ce
8. Add 5 The Exception Site List dialog will appear In the white box enter the following and then click OK http IP address of AE 200 AE 50 or EW 50 Note If the IP address of the AE 200 is 192 168 1 1 enter http 192 168 1 1 Note When using HTTPS SSL connection prefix the web address with https https IP address of AE 200 AE 50 or EW 50 6 The security warning screen will appear Click Continue Note The security warning screen will not appear when HTTPS SSL connection is used WT07140X02 8 Java Control Panel E ace Ex General Update Java Advanced About View version information about Java Control Panel Network Settings Network settings are used when making Internet connections By default Java will use the network settings in your web browser Only advanced users should modify these settings Temporary Internet Files Files you use in Java applications are stored in a special folder for quick execution later Only advanced users should delete files or modify these settings Settings View Java in the browser is enabled See the Security tab General Update Java Security Advanced V Enable Java content in the browser Security level for applications not on the Exception Site list Very High Only Java applications identified by a certificate from a trusted authority are allowed to
9. PWFY unit group and HWHP CAHV CRHV unit group Schedule set Fitri ef Group icons This icon will not appear for the HWHP CAHV CRHYV unit groups 2 The Water temperature display icon will not appear for the HWHP CAHV CRHV unit groups 4 General equipment group O N oF Eror Scheduleset Schedule disabled HOLDON ON Note Besides the lighting icons pump or card key icons are also available The icon can be selected on the group settings screen accessible via the Web Browser for Initial Settings WT07140X02 1 5 4 1 2 Checking the operation conditions of HWHP CAHV CRHV unit groups In the Air conditioners HWHP section select HWHP to display the operation conditions of the HWHP CAHV CRHV unit groups Note The HWHP button will not appear if no HWHP CAHV CRHV units have been registered to any group oO eee 192 prea Fin z Batch Operations i MITSUBISHI Air Conditioning Control System Click to operate the units in l all HWHP CAHV CRHV unit groups at once Monitor Operation Condition List Update E Condition List H Overview Floor Layout fll HWHP Click to show the most s Air conditioners HWHP R p Update Batch Operations Weekly1 in period recent operation conditions Lobby W Heat Representative Temp Outdoor Temp Brine Temp Inlet Temp Outlet Temp Weekly SC hed u le num ber 40 0 C 44 0 C 7 0 2 0
10. Air To Water PWFY unit groups and general equipment groups 4 1 1 Checking the operation conditions of all groups HWHP CAHV CRHV unit groups excluded In the Air conditioners HWHP section select Air conditioners to display the operation conditions of air conditioning unit groups LOSSNAY unit ventilator groups Air To Water PWFY unit groups and general equipment groups Batch Operations Click to operate the units in all groups HWHP CAHV CRHV unit groups Monitor Operation excluded at once Condition List W Condition List Update Co J http 192 168 1 1 en index htm File Edit View Favorites Tools Help Air conditioners HWHP J Air conditioners li HWHP Weekly1 in period Update Click to show the most recent operation conditions Batch Operations a Weekly schedule number Indicates the weekly schedule that is currently effective Entrance Lobby South pt Heat 50 SA Auto cee FI 28 50 z a By 25 A 25 ESR Iae A j Lobby East Lobby Center Fan C E Auto err e 23 50 gt 8 O Group name Lobby VVest Conference Room A Auto me A Heat 26 C ZN 28 50 26 C Set temperature gt 8 O Conference Room B Conference Room C R h id it To Bor g B a 50 WB 25 oom humidity 9 Conference Room D 10 Conference Room E E o Em or 7
11. Wi Heat Gq ov on Room temperature Operation mode Group icons The icons indicate the operation conditions of groups Click the icon to switch to the operation screen No O Click Air conditioners to display the operation conditions of air conditioning unit groups Air conditioners HWHP LOSSNAY unit groups Air To Water PWFY unit groups and general equipment groups and click HWHP to display the operation conditions of HWHP CAHV CRHV unit groups Update Click to show the most recent operation conditions Batch Operations oes nes the units in all groups HWHP CAHV CRHV unit groups excluded at once See The name of the group will appear Operation mode The operation mode of the group will appear The set temperature of the group will appear Note For Air To Water PWFY unit groups the set water temperature will appear Note The temperature unit C or F can be set on the Basic System settings screen accessible via the Web Browser for Initial Settings Set temperature Indoor unit return air temperature will appear Note The temperature shown may be different from the actual room temperature Room temperature Note For Air To Water PWFY unit groups the current water temperature will appear Note The temperature unit C or F can be selected on the Basic System settings screen accessible via the Web Browser for Initial Settings WT07140X02 1 3 Description The reading of
12. operation settings screen for HWHP CAHV CRHV unit groups The fan can be set to keep rotating even while the unit is stopped to avoid snow accumulation on the fan guard during the winter Select Normal to stop the fan while the unit is stopped Select Snow to operate the fan even while the unit is stopped Click Reset to switch between resetting and not resetting the filter sign The rectangular icon next to Reset will appear in yellow green when it is set to Reset ff Note If a filter sign in the group has not been triggered then the item Filter Sign Reset will not appear Note After the filter sign is reset it takes up to an hour to clear the filter sign display on the local remote controllers Click ON or OFF to turn on or off the interlocked LOSSNAY unit Note For a group that is not connected to an interlocked LOSSNAY unit ventilator the item Interlocked ventilator ON OFF will not appear Click Lai or CF to adjust the fan speed of the interlocked LOSSNAY unit ventilator Note For a group that is not connected to an interlocked LOSSNAY unit the item Fan speed of interlocked LOSSNAY will not appear Prohibition icon will appear next to the item whose operation is prohibited If one or more operation items are prohibited Centrally Controlled will appear The item may not be displayed depending on the unit model 4 1 4 Operating the units in all groups 1 In the Air conditioners displa
13. the menu bar then click Internet options File Edit View Favorites REGASI Help Delete browsing history Ctrl Shift Del Th e web pag InPrivate Browsing Ctrl Shift P Tracking Protection ActiveX Filtering Things to try Diagnose connection problems Reopen last browsing session Connect ta Add site to Start menu Make sure View downloads Ctrl J check mark Pop up Blocker gt SmartScreen Filter gt For offli me foremoe Manage add ons Compatibility View Compatibility View settings Subscribe to this feed Feed discovery gt Windows Update F12 developer tools Sun Java Console Internet options WT07140X02 6 2 In the Internet Options window click the Connections tab ep To set up an Internet connection click Setup Dial up and Virtual Private Network settings 3 Check the radio button next to Never dial a connection in the middle S 4 Click LAN settings under Local Area Network LAN settings severferscomeion o n SPO Never dial a connection Dial whenever a network connection is not present Always dial my default connection Current None Set default Local Area Network LAN settings ttings do not apply to dial up connections ttings LAN Se Choose Settings above for dial up settings 5 In the Local Area Network LAN Settings window check Bypass proxy server for local addresses and click Advanced
14. Mitsubishi Electric CA 08064 215 You should confirm its origin by contacting Mitsubishi Electric CA 08C64 215 The following number will assist you in this process Thumbprint shal EFLEEFEE 76FECBAO D1C35A0B 1A502B73 73FEC9C8 Warning If you install this root certificate Windows will automatically trust any certificate issued by this CA Installing a certificate with an unconfirmed thumbprint is a security risk If you click Yes you acknowledge this risk Do you want to install this certificate Se WT07140X02 12 4 Monitor Operation This chapter explains how to monitor the operation conditions of all groups collectively and how to operate each group or all groups collectively 4 1 Condition List On the Condition List screen the operation conditions of all groups can be monitored The operator can also check the unit malfunctions on this screen and prevent the units from being left on unintentionally This section explains how to monitor the operation conditions of all groups HWHP CAHV CRHV unit groups excluded collectively See section 4 1 1 how to monitor the operation conditions of HWHP CAHV CRHV unit groups see section 4 1 2 and also explains how to operate each group see section 4 1 3 or all groups collectively see section 4 1 4 After login a Condition List screen will appear which shows the operation conditions of all air conditioning unit groups LOSSNAY unit ventilator groups
15. UBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT07140X02
16. W 50A but not on the AE 200E AE 50E EW 50E Click Lai or 0 to adjust the set temperature of the air conditioning unit or the Air To Water PWFY unit Note The settable temperature ranges depend on the unit model Note If the indoor unit supports the dual set point function in the AUTO mode and when the operation mode above is set to Auto or Setback two set temperatures for Cool mode and Heat mode can be set Set temperature 1 Note When the indoor units that support the dual set point function and the indoor units that do not support the dual set point function exist in the same group only one set temperature can be set in the AUTO mode Note The temperature range restrictions settings on the Set Temperature Range Limit settings screen on the Web Browser for Initial Settings will be effective on this screen Note The temperature unit C or F can be selected on the Basic System settings screen accessible via the Web Browser for Initial Settings Click ai or F to adjust the air direction Mid 3 Horizontal ON OFF Operation mode 1 er sago Jra Air Direction 1 Note Available air directions depend on the unit model WT07140X02 17 Fan Speed 1 Fan Mode 1 Filter Sign Reset Interlocked LOSSNAY ON OFF Fan speed of interlocked LOSSNAY Prohibition icon Click Lai or F to adjust the fan speed Note Available fan speeds depend on the unit model This item will appear only on the
17. aily Controiie L i Operation mode Mode Cool IDy Ean Heat HAuto Setback Ose Ventilation ON OFF Set Temp Air Direction Fan Speed HON OFF Set temperature i a Fan speed Cool Paar ee Para Ns pra Boca a Ep Hest EA a Air direction Fan speed of interlocked LOSSNAY Filter Sign Reset Cancel oke OK iick ae Click to reflect the changes ick to return to the made previous screen without R10 making any changes Click Air conditioners to display the operation conditions of air conditioning unit groups Air conditioners HWHP LOSSNAY unit groups Air To Water PWFY unit groups and general equipment groups and click HWHP to display the operation conditions of HWHP CAHV CRHV unit groups Click ON or OFF to turn on or off the units in a given group Note Switching this switch will turn on or off the LOSSNAY unit as well that is interlocked with the operation of indoor units in the group To turn on or off the LOSSNAY unit only use the Interlocked LOSSNAY ON OFF switch Click the desired operation mode Air conditioning unit Cool Dry Fan Heat Auto Setback LOSSNAY unit Heat Recovery Bypass Auto Air To Water PWFY unit Heating Heating ECO Hot Water Anti freeze Cooling HWHP CAHV CRHV unit Heating Heating ECO Hot Water Anti freeze Note Only the operation modes available for the unit model will appear Note The Setback mode can be selected on the AE 200A AE 50A E
18. en will appear Note If the IP address of the AE 200 AE 50 EW 50 is 192 168 1 1 the web page address is http 192 168 1 1 index html Note Default IP address of AE 200 AE 50 and EW 50 is 192 168 1 1 When one or more AE 50 EW 50 controllers are connected none of their IP addresses should overlap The recommended IP address ranges are as follows RAEADR AE 200 Between 192 168 1 1 and 192 168 1 40 Username AE 50 EW 50 when used for system expansion Between 192 168 1 211 and 192 168 1 249 EW 50 when used alone Between 192 168 1 1 and 192 168 1 40 Note Log in to the AE 200 AE 50 or EW 50 Web browser respectively to monitor or operate the units that are under the control of AE 200 AE 50 or EW 50 The Web browser cannot be switched among the AE 200 AE 50 and EW 50 Note If the login screen does not appear then take the steps below to delete the temporary files lt Internet Explorer gt 1 Click Tools in the menu bar then click Internet options 2 On the General tab click Delete in the middle of the window 3 In the Delete Browsing History window click Delete lt Java gt 1 Click Control Panel from the Start menu 2 Click the Java icon to launch the Java Control Panel 3 On the General tab click Settings in the Temporary Internet Files section 4 Click Delete Files 5 In the Delete Files and Applications window click OK E Login Page
19. he javacpl exe file in the bin folder 11 Java Control Panel will open Follow the steps 3 through 8 again 2 3 2 How to enable Java content 1 Open the security setting window See section 2 3 1 How to register exception site list 2 Click on the checkbox next to Enable Java content in the browser SSS unless it is already checked Click Apply at the right bottom corner of the screen and then click ae som ee O K Very High Only Java applications identified by a certificate from a trusted authority are allowed to run and only if the certificate can be verified as not revoked High Java applications identified by a certificate from a trusted authority are allowed to run even if the revocation status of the certificate cannot be verified Exception Site List Applications launched from the sites listed below will be allowed to run after the appropriate ty prompts Edit Site List Restore Security Prompts Manage Certificates rya Cancel Apply 3 After completing the settings close all Internet Explorer windows and access the Web page again to make sure the appropriate window will appear WT07140X02 9 3 Logging in to the Web Browser for User 1 Enter the web page address in the address field of the Web browser as follows http IP address of each AE 200 AE 50 or EW 50 index html Press the Enter key A login scre
20. how occupancy icon Show vacancy icon or Show both icons is selected in the Occupancy sensor display section under the Display Format section of the Basic System settings screen accessible via the Web Browser for Initial Settings 4 The Occupancy Vacancy status icon will not appear if the remote controller in the group does not have an occupancy sensor 5 The Occupancy Vacancy status icon takes priority over the Interlocked LOSSNAY ON or Interlocked LOSSNAY OFP icon 6 The Brightness Darkness status icon will appear only when Show bright symbol Show dark symbol or Show both symbols is selected in the Brightness sensor display section under the Display Format section of the Basic System settings screen accessible via the Web Browser for Initial Settings 7 The Brightness Darkness status icon will not appear if the remote controller in the group does not have a brightness sensor 8 The Setback ON icon takes priority over the Brightness Darkness status icon 9 The Starting up icon will stay when the unit cannot be recognized after startup Check for proper connection of the air conditioning unit and proper group settings 10 The Hold function can be used on the AE 200A AE 50A EW 50A but not on the AE 200E AE 50E EW 50E WT07140X02 14 Description 2 LOSSNAY unit ventilator group Filter sign ON Es E M Schedule set Energy saving ON Schedule disabled HOLD ON 3 Air To Water
21. neral public it is recommended that the following settings be made so that the units are monitored and controlled on the encrypted web page Note Depending on the operating system or the Java version HTTPS encrypted communication may not be enabled properly If this happens use an HTTP connection as explained in the previous page 1 Prefix the web address with https enter the rest of the address and press the Enter key https IP Address of each AE 200 AE 50 or EW 50 index html Note If the IP address of the AE 200 AE 50 EW 50 is 192 168 1 1 the web page address is https 192 168 1 1 index html The encrypted data communication will begin and the Login screen will appear When the first time the Web browser is accessed a security certificate error page appears instead of the Login screen Go to step 2 below H Login Page User name R100 2 Enter the following web page address in the address field of the Web browser and press the Enter key http IP address of each AE 200 AE 50 or EW 50 cacert cer 3 A notification bar or a window to confirm about file download will appear Click Open 4 A certificate dialog will appear Click Install Certificate WT07140X02 11 File Download Security Warning Do you want to open or save this file Name cacert cer EA Type Security Certificate 1 57KB From 192 168 1 1 Open
22. ntralized Controller EW 50A EW 50E is referred to as EW 50 Booster unit and Water HEX unit are referred to as Air To Water PWFY unit Hot Water Heat Pump unit is referred to as HWHP CAHV CRHV unit Screen images used in this manual are from Windows 7 and Internet Explorer 9 0 Note Windows is a registered trademark or trademark of Microsoft Corporation in the United States and other countries 1 2 PC Requirements Table1 1 PC Requirements Microsoft Internet Explorer 8 0 Microsoft Internet Explorer 9 0 Microsoft Internet Explorer 10 0 Microsoft Internet Explorer 11 0 Java execution environment is required BIOS Verified to run on Oracle Java Plug in Ver 1 8 0 25 Install Oracle Java Plug in that is appropriate for your operating system When using a 64 bit OS install a 32 bit and a 64 bit Java Plug in The version of the Oracle Java Plug in can be verified by clicking Java in the Control Panel On board LAN port or LAN card 100 BASE TX Note Microsoft is a registered trademark or trademark of Microsoft Corporation in the United States and or other countries Oracle and Java are trademarks or registered trademarks of Oracle Inc in the United States and or other countries Note Although no particular OS is required the Web browser will not properly operate when it is started up from the Internet Explorer on the Windows 8 1 start screen If the Web browser
23. onnect tq Add site to Start menu Make sure View downloads Ctrl J check mark Pop up Blocker gt E p SmartScreen Filter gt For offline AEPA Compatibility View Compatibility View settings Subscribe to this feed Feed discovery gt Windows Update F12 developer tools Sun Java Console Internet options Internet Options ep To set up an Internet connection click Setup Dial up and Virtual Private Network settings amp Dial up Connection Choose Settings if you need to configure a proxy server for a connection Never dial a connection Dial whenever a network connection is not present Always dial my default connection Current None Set default Local Area Network LAN settings LAN Settings do not apply to dial up connections Choose Settings above for dial up settings ox cane amv 2 2 2 Dial up Internet connection To monitor and operate the air conditioning units from a PC that connects to the Internet through a dial up connection follow the instructions below to set the environment for the Web browser 1 Click Tools in the menu bar then click Internet options Sa a http 192 168 1 1 en index html File Edit View Favorites EGATI Help o Delete browsing history Ctrl Shift Del ri The webp ag InPrivate Browsing Ctrl Shift P Tracking Protection ActiveX Filtering Things to try Diagnose connection problems Reo
24. orities click OK and then click Next Windows can automatically select a certificate store or you can specify a location for the certificate Automatically select the certificate store based on the type of certificate Place all certificates in the following store Certificate store es Select the certificate store you want to use Personal a E 3 Enterprise Trust d D Intermediate Certification Authorities i Trusted Publishers SA lintirueted Certificates m qil ie 7 Click Finish on completing the Certificate Import Wizard F Show physical stores lt Back Next gt cancel Completing the Certificate Import Wizard The certificate will be imported after you click Finish You have specified the following settings fe aiie lBejee a SAE Trusted Root Certificc Content Certificate 8 Click Yes on the security warning to install the certificate 9 Certificate import process starts A window will appear when the import completes successfully Click OK Note The valid period of the certificate is from April 1st 2014 to January st 2051 The system date and time of the PC must be within the period Security Warning A You are about to install a certificate from a certification authority CA claiming to represent Mitsubishi Electric CA 08064 215 Windows cannot validate that the certificate is actually from
25. pen last browsing session Connect ta Add site to Start menu Make sure View downloads Ctri J k check mark Pop up Blocker gt i SmartScreen Filter gt For offline ge a Compatibility View Compatibility View settings Subscribe to this feed Feed discovery gt Windows Update F12 developer tools Sun Java Console Internet options 2 In the Internet Options window click the Connections tab hp To set up an Internet connection click Setup Dial up and Virtual Private Network settings 3 Check the radio button next to Dial whenever a network connection soos is not present in the middle of the window and click OK to close the window a etn eee ny By making these settings a message will appear asking whether een A or not to use a dial up connection when an Internet connection is le Current None necessary Follow the message to connect to the Internet Local Area Network LAN settings LAN Settings do not apply to dial up connections Choose Settings above for dial up settings o _ cae ay 2 2 3 Connecting to the Internet via proxy server using an existing LAN To monitor and operate the air conditioning units from a PC that connects to the Internet through a proxy server by connecting to an existing LAN such as a LAN within your company follow the instructions below to set the environment for the Web browser 1 Click Tools in
26. re Note The temperature unit C or F can be selected on the Basic System settings screen accessible via the Web Browser for Initial Settings The representative water temperature outdoor temperature brine temperature inlet water temperature and outlet water temperature will appear Note When there is a communication error the temperature value will be Note The brine temperature will not appear for HWHP CAHV unit groups Note The temperature unit C or F can be selected on the Basic System settings screen accessible via the Web Browser for Initial Settings The fan mode of the group will appear CAHV model only Temperature WT07140X02 1 6 4 1 3 Operating the units in a given group In the Air conditioners display of the Condition List screen click one of the group icons to display its operation settings screen which shows the current operation conditions Change the desired settings and click OK to reflect the changes Click Cancel to return to the previous screen without making any changes Note To operate an HWHP CAHV CRHV unit group click the icon of the group on the HWHP display of the Condition List screen Group name Go J http 192 168 1 1 en index htm Yr Ox MITSUBISHI Air Conditione File Edit View Favorites Tools Help Monitor Operation Centrally Controlled Condition List mark Meeting room 1F ON OFF ee ss Interlocked LOSSNAY OFF entr
27. run and only if the certificate can be verified as not revoked High Java applications identified by a certificate from a trusted authority are allowed to run even if the revocation status of the certificate cannot be verified Exception Site List Applications launched from the sites listed below will be allowed to run after the appropriate security prompts Click Edit Site List o add items to this list Edit Site List Restore Security Prompts I Manage Certificates Apply Applications launched from the sites listed below will be allowed to run after the appropriate security prompts Click Add to add an item to this list R R e ee temove ha FILE and HTTP protocols are considered a security risk We recommend using HTTPS sites where available Applications launched from the sites listed below will be allowed to run after the appropriate security prompts Location ttp 192 168 1 1 R temoave hy FILE and HTTP protocols are considered a security risk We recommend using HTTPS sites where available Including an HTTP Location on the Exception Site List is considered a security risk Location http 192 168 1 1 Locations that use HTTP are a security risk and may compromise the personal information on your computer We recommend including only HTTPS sites on the Exception Site List Click Continue to accept this location or Cancel to abort this change
28. system administrator to decide the IP subnet mask and gateway addresses Subnet mask 255 255 255 0 Default gateway Obtain DNS server address automatically Use the following DNS server addresses Preferred DNS server 5 Keep clicking OK or Close to close all windows Alternate DNS server E Validate settings upon exit WT07140X02 4 2 2 Setting the Web Browser Web browser setting varies with the Internet connection type See the sections below for how to make Web browser settings for different types of Internet connection To prevent unauthorized access always use a security device such as a VPN router when connecting the AE 200 AE 50 EW 50 to the Internet 2 2 1 No Internet connection To monitor and operate the air conditioning units from a PC with no Internet connection follow the instructions below to set the environment for the Web browser 1 Click Tools in the menu bar then click Internet options 2 In the Internet Options window click the Connections tab 3 Check the radio button next to Never dial a connection in the middle of the window and click OK to close the window WT07140X02 5 File Edit View Favorites MESAI Help n Delete browsing history Ctrl Shift Del The webp ag InPrivate Browsing Ctrl Shift P h Tracking Protection ActiveX Filtering Things to try Diagnose connection problems Reopen last browsing session C
29. the humidity sensor on the ME remote controller North America PAR U01MEDU Europe PAR U02MEDA will appear Room humidity Note If an ME remote controller North America PAR UO01MEDU Europe PAR UO02MEDA is connected to the group and the built in humidity sensor is enabled the reading of the sensor will appear Each group icon indicates the operation condition of the group Move the cursor to the icon to display its group name Clicking the icon will bring up the operation screen The icons to indicate the operation conditions are shown below 1 Air conditioning unit group 2 A Filter sign ON Interlocked Interlocked OSSNAY ON 1 5 LOSSNAY OFF 2 5 OFF 2 5 Schedule set Schedule disabled DE Yellow Gray Group icons Note Besides the 4 way airflow unit icons 2 way airflow or ceiling suspended unit icons are also available Icons can be selected on the group settings screen accessible via the Web Browser for Initial Settings 1 If the LOSSNAY unit is interlocked with the operation of Mr Slim units Interlocked LOSSNAY ON icon will appear even when the LOSSNAY unit is operated individually Applicable M NET adapter model PAC SF48 50 60 70 80 81MA E 2 Ifa LOSSNAY unit is interlocked with the operation of indoor units in multiple groups the LOSSNAY unit may be in operation even when the Interlocked LOSSNAY OFF icon is displayed 3 The Occupancy Vacancy status icon will appear only when S
30. was started up on the start screen close the Web browser and switch the screen to the desktop screen and then start up the Web browser again Refer to the help functions of Windows 8 1 for how to switch the screens Start screen Desktop screen WT07140X02 2 2 Setting the Operating Environment This chapter explains how to make PC settings and Web browser settings to monitor and operate the air conditioning units 2 1 Setting the IP Address of the PC Follow the instructions below to set the PC s IP address for the Web browser to recognize the AE 200 AE 50 EW 50 unit The PC s IP address must have the same network address as the AE 200 AE 50 EW 50 s IP address i e AE 200 s IP address 192 168 1 1 PC s IP address 192 168 1 101 When connecting an AE 200 AE 50 EW 50 to an existing LAN consult the system administrator to decide the IP addresses Note When using an AE 200 AE 50 EW 50 dedicated LAN it is recommended that the AE 200 unit and the EW 50 unit only when used alone be assigned an IP address between the range 192 168 1 1 and 192 168 1 40 the AE 50 EW 50 unit be assigned an IP address between the range 192 168 1 211 and 192 168 1 249 and that the PC connected to the AE 200 AE 50 EW 50 be assigned an IP address between the range 192 168 1 101 and 192 168 1 150 1 Click Control Panel in the Start menu Computer EW Windows Media Center Control Panel s s Calculator sf
31. y of the Condition List screen click Select the operation units Batch Operations If air conditioner group LOSSNAY unit ventilator group Air To Water PWFY unit group and general equipment group exist together in the same system a screen to select a group type will appear Click one of the group types to change its settings Note To operate all HWHP CAHV CRHYV unit groups click Batch Operations in the HWHP display of the Condition List screen 2 On the operation settings screen change the desired settings and click OK to reflect the changes Click Cancel to return to the previous screen without making any changes a o LSE venantan Note The settable temperature range is limited for the group whose set e Sm By a fas c A i ya a temperature restrictions settings have been made Note If any group out of the given groups has an operation item that is prohibited the item for the group can not be operated axe WT07140X02 18 WT07140X02 19 This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations e Low Voltage Directive 2006 95 EC e Electromagnetic Compatibility Directive 2004 108 EC e Restriction of Hazardous Substances 2011 65 EU Please be sure to put the contact address telephone number on this manual before handing it to the customer MITS

Download Pdf Manuals

image

Related Search

Related Contents

HP EliteBook 8540p  Dakota Japan  メーカーデータ  Edge® 1000  Phototherapy  MANUAL TÉCNICO INTEGRACIÓN VÍA LINK  Manuale d`Uso e Manutenzione Carrello elevatore  Autopilot Controls (User Manual - Ver 1.0)  participación y de registro.  Topcom T41  

Copyright © All rights reserved.
Failed to retrieve file