1. N PPS SPORTS MACHINES TENDO Weightlifting Analyzer Version V 207 A microcomputer system for strength diagnostic and feedback monitoring of weight training USER S MANUAL www tendosport com Why use TENDO Weightlifting Analyzer One of the most exciting things going on now in athletics is the use of weight training to improve performance in other sports Weights are used to develop explosive power maximum strength and muscular endurance to correct muscular weakness and imbalance to prevent or rehabilitate injuries and to improve technique and performance in virtually every sport For example a person may have a lot of strength at bench press but not be able to do shot put well He doesnt have the speed of movement that combined with strength generates the necessary power for a long throw Strength in and of itself does not guarantee high performance Power is the most important ingredient in many sports It is an athlete s ability to rapidly develop strength It is a product of strength and velocity of muscular contraction Human muscle is composed of two very general types of fibers fast twitch and slow twitch All people have both fast and slow twitch fibers Fast twitch fibers contract faster and can produce more explosive movements but they fatigue faster You can not change the ratio of fast twitch and slow twitch fibers in your body but weight training can maximize development of those fast twitch fibe
2. microcomputer 2 Plug the other end of the VSU Cable into the appropriate connector on your Velocity Sensor Unit TWA V 207 and tighten 2 screws The Velocity Sensor Unit TWA V 207 is used for Weightlifting Analyzer only p A 1 2 Battery Installation Before the microcomputer is operated 4 AA batteries must be installed batteries included Batteries are supplied discharged and must be charged before use charger included Refering to the insert drawing locate the batteries into compartments on the back of the microcomputer Press two batteries into each battery compartment MAKE SURE that the negative ends of the batteries marked are touching the springs marked in the battery compartment Average Power control LED light should be flashed lf a NET Interface option is used it is not necessary to install the batteries The power for microcomputer is supplied from the interface sama Battery compartments If the microcomputer is turn on and the brightness of LED display is lower or in upper display flash sign Lbat law battery power the batteries need to be charged It is possible to use an external power supply with Regulated AC DC Adaptor min 200mA output DC 9 12V polarity in the midpoint of connector Ce Tendo Weightlifting Analyzer Microcomputer Set does not include an External Power Supply Adapter 2 Technical description The system consists of 2
3. sequence from the top down as listed on the daily program sheet Weight training focused on improvement of explosive power Resistance training focused on the improvement of explosive power requires intensity of exercise close to one s maximum to guarantee stimulation of all namely FTG glycolytic muscle fibers Repetitions performed below a certain critical level of maximum average power e g 90 either because of lower motivation or fatigue do not optimally stimulate improvement of explosive power The ability to perform repetitions close to one s maximum is individual and depends on a variety of factors namely on an individual ratio of fast and slow twitch fibers In addition audio signal indicating decrease of average power below critical level e g 90 is available This should be a signal that muscle fatigue exceeded acceptable level and rest interval is necessary 1 Connect microcomputer and velocity sensor unit by the cable 2 Fasten the cord of the velocity sensor unit to the bar of barbell or to upper weight of the weight stack 3 Position velocity sensor unit on the floor so that the trajectory of the cable is as close to perpendicular to the floor as possible while doing the exercise 4 Adjust filter value 5 Adjust audio signal limits for monitoring fatigue of fast twitch muscle fibers Lower limit 90 decrease of average power below 90 of max average power will be indicated by means of short beep Upper lim
4. alue of the best repetition in particular set will be displayed middle display While performing an exercise set the average power in the first repetition will be set as 100 The power of subsequent reps will be displayed also as percent values of this maximum However should the second or any subsequent repetition be higher than the previous one its value will be considered as the new 100 which all the subsequent reps will be compared to Data from up to 200 repetitions can be stored and later retrieved from the memory Pressing the Reset button clears the memory recalls the weight inout mode and makes the system ready for the next exercise set The microcomputer has a build in battery saver to prolong the battery life After 2 minutes of microcomputer rest period the battery saver is turn on 4 LED lights flashing clockwise and the microcomputer switch off the displays The battery saver is turn off automatically by pulling of Velocity Sensor Unit cable or pressing any key Do not press Reset or On Off button It clears the memory and you will lose all data 5 How to utilize TENDO Weightlifting Analyzer in practice 5 1 ATHLETES to increase the efficiency of strength training The athlete has two options for the order in which to perform the exercises prescribed by the coach First the athlete may perform all the sets for exercise one then move to the next exercise Second the athlete may follow the order of exercises in
5. cted from all out reps with different weights Such an approach provides more sensitive method for detection of specific adaptation changes due to different forms of weight training e g slow or fast than the estimation of 1 RM Studies show that maximum average power the subject can produce by using weights that are 50 of 1 RM represents a substantially more sensitive parameter for the assessment of strength training than 1 RM itself 5 3 WEIGHTLIFTING EXERCISES Hang Snatch It is important to set up the correct value of the Filter for weightlifting exercises see table 1 Table 1 name Snatch Clean Pull Pull Clean Snatch Filter ele ee Te ee ee ee Ine value cm cm cm cm cm cm cm feee bol ee ie a A name press raise Filter EEC value 8 12 cm 6 MAINTENANCE and TROUBLE SHOOTING The TENDO Weightlifting Analyzer can be cleaned with a soft damp cloth Avoid spilling liquid on the microcomputer and velocity sensor unit Keep the microcomputer out of direct sunlight Remove the batteries when storing the Weightlifting Analyzer If the microcomputer does not function properly the batteries should be charged n addition make sure that the microcomputer wire is connected to the velocity sensor unit Check the Filter The value of Filter has to be set less than amplitude of the motion For indoor use only Do not let the cord with strap of the Velocity Sensor Unit rolls spontaneous The TENDO Weightl
6. e Filter just cause to not show measurement results for motion shorter then the setting value of the Filter Remember The value of Filter has to be set less than amplitude of the motion 3 3 How to adjust the filter and the audio signal Decrease increase of average power or average velocity below above a certain predefined percent value of max power velocity will be indicated by means of short beep triple beep 1 Press velocity power button hold and press once reset button The upper L E D display will begin displaying the value of the filter in centimeters from 1 to 150 cm 2 To adjust the value of the filter use up down keys press and hold for fast change 3 Press velocity power button The middle LED display will begin displaying the value of the upper limit of audio signal 4 To adjust the value of upper limit of audio signal use up down keys press and hold for fast change 5 Press velocity oower button and the lower LED display will begin displaying the value of the lower limit of audio signal 6 To adjust the value of lower limit of audio signal use up down keys press and hold for fast change 7 Press reset button 4 How the microcomputer operates After switching the microcomputer the weight of the barbell or stack is to be set using up down keys After each repetition its serial number lower display average or peak velocity in m s or average or peak power in Watts upper display and percent v
7. functional components a Velocity Sensor Unit and a Microcomputer Velocity sensor unit is connected to the weight by means of special kevlar cord with strap with velcro In weight exercise the muscles lift a mass m by applying a force F equal to m g at velocity v producing power P equal to F v The system measures upward vertical average and peak velocity of the weight lifted Using known mass input prior to the exercise the system calculates average power and the power at peak velocity in concentric phase of weight exercise The microcomputer with LED displays will show average and peak velocity average power power at peak velocity and number of repetition and the percent value of the best repetition in a particular set 3 How to prepare the system for exercise 3 1 How to connect the velocity sensor unit to barbell or exercise machine Fasten cord strap of the sensor unit to the bar of the barbell or dumbell or on the top weight of the weight stack system Position the cord output of the unit so that the trajectory of the cord Is as close to perpendicular to the floor as possible while doing the exercise 3 2 How to set up the microcomputer WEIGHTLIFTING ANALYZER V 207 AVERAGE POWER WO averace a VELOCITY m s VELOCITY m s Upper display Velocity power button Middle display cc1ccceeeee ON OFF buttON 0000e0ee Reset DuttOn 00000 cecceeeee ae Lower dis
8. ifting Analyzer package includes wg 1 Microcomputer 2 Velocity sensor unit 3 Tripod 4 Set of rechargeable batteries 5 Battery charger 6 Carrying bag Tendo Weightlifting Analyzer can also be interfaced with a computer to run up to 8 stations simunltaneously Computer software and interface is an additional option in this model The Tendo Unit in Practice For measurement of power and velocity for legs power and velocity for lower extremities only without back muscles positive influence attach the sensor unit cord on the waist belt under the athlete s hips ee i Teaching the athletes use power from legs for Olympic lifts testing leg s velocity and power If the sensor unit is attached on the bar the barbell velocity and power is measured Manufactured in Europe TENDO Sports Machines Phone fax 00421 32 6401500 M R Stefanika 19 e mail tendo tendosport com 91101 Trencin Slovak Republic WWW tendospor t com 10
9. it 100 if upper limit is 99 any subsequent repetition with maximum average power is indicated by a triple beep 6 Set the weight of barbell or resistance of the exercise machine 7 Choose the exercise to be performed 8 Perform the exercise with maximum effort 9 Stop the exercise set after average power decrease below 90 audio signal indicates decrease of power This ts a signal that fatigue exceeded an acceptable level and a rest interval is necessary 10 Take a rest between the sets approximately 1minutes and 30 seconds and then perform the exercise set again 11 If the intensity of the repetitions at the beginning of the next set is too close to the lower limit 90 stop the exercise either because of fatigue or lower motivation do not optimally stimulate improvement of explosive power 12 Choose another exercise and repeat steps 7 10 This way is for an athlete who performs all the sets for each exercise If the athlete follows the order of exercises in sequences the most important is to file the value of power in critical level of maximum average power 90 for each exercise in the first set Stop the next exercise sets for each exercise after average power decrease below critical level of maximum average power 90 Do not use the peak power value to monitor muscle fatigue The average value of power or velocity is more sensitive parameter to monitor muscle fatigue Weight training focused on improvement of the musc
10. play Down button Up button 1 To turn on the power press the ON OFF button 2 When the power is turned on the lower LED display will begin displaying weight To adjust the weight of barbell or weight stack use up down keys press and hold for fast change 3 After each repetition its serial number begins displaying lower display actual value of average peak velocity or average peak power choose average peak power or average peak velocity by pressing power velocity button on the upper display and percent value of the best repetition in a particular set on the middle display the percent value is displayed for average power or average velocity only the average values are more sensitive for muscle fatigue monitoring FILTER Fitler is a way how not to show unwanted motion FILTER isa limit from 1 to a certain predefined value of range of motion in centimeters 10 centimeters 0 1 meter which microcomputer does not show It means the exercise range of motion has to be longer than the value of the Filter For most of the exercises we suggest to set Filter to 35 cm less then amplitude of the motion For exercises with very short amplitude e g toe raise we suggest to set Filter to 10 cm For exercises with very long amplitude Olympic lifting exercises we suggest to set Filter to more than 80 cm The microcomputer system measures from the lowest position to the top The Filter does not have any influence on measured range Th
11. rs you do have Resistance training focused on the improvement of explosive power requires an intensity of exercise close to one s maximum to guarantee stimulation of all namely FTG glycolytic muscle fibers The movement must be always at least 90 of max power outout measured in watts Hamar Bosco In weight training particular repetitions in an exercise set with a given weight can be performed at different rates and also with different power outout in the concentric phase of muscular contraction Although the same weight is used different physiological mechanisms are involved and hence different adaptation processes can be expected Repetitions performed at below a certain critical level of maximum average power 90 either because of lower motivation or fatigue do not optimally stimulate development of fast twitch muscle fibers The utilization of such a philosophy supported by TENDO Weightlifting analyzer substantially increases the efficiency of resistance training TENDO Weightlifting Analyzer by TENDO Sports Machines TENDO Weightlifting Analyzer V 207 A microcomputer system for strength diagnostic and feedback monitoring of weight training The purpose of this manual is to guide you through the first basic steps necessary to set up the system and give you an idea how to begin 1 Instalation steps 1 1 Connecting to a microcomputer 1 Plug the male connector on your VSU Cable into the connector in the front of the
12. ular endurance Resistance training focused on the improvement of muscular endurance requires intensity of exercise below a certain critical level of maximum average power 80 This intensity ensures not to recruit fast twitch muscle fibers glycolytic Set upper limit of audio signal to 80 increase in power above 80 of max average power Is indicated by triple beep Set lower limit of audio signal to 60 decrease in average power below 60 of max average power is indicated by single beep Perform first and second repetition of the exercise set with maximum effort and next repetitions perform within 80 and 60 of the maximum average power 5 2 COACHES quick test set up for assessment of athlete s strength abilities How to find out the optimum weight for maximum power A typical test routine consists of maximum effort repetitions with an incremental increase in weight up to 1 RM For instance in bench press an initial weight of 50 Ib is to be increased by 20 Ib at the beginning As the weight approaches 1 RM smaller increases 10 Ib or 5 lb may be more appropriate From each repetition mass average peak velocity and average power should be recorded Using these data the individual velocity weight as well as power weight curves can be drawn VELOCITY mi POWER 1 2 da M500 1 0 8 0 6 0 4 0 2 10 20 30 40 50 606 70 80 90 4100 WEIGHT kg FIG 6 Velocity weight and power weight curves based on data colle