Home

HDS-5x Quick Start Guide

image

Contents

1. HDS 5x Quick Start Guide Pub 988 0176 03A HDS works very much like previous Lowrance products but there are some changes that make it even easier to use Read this guide to quickly familiarize yourself with your new display For more details on any of the features mentioned here consult the user s manual Arrow Keypad ZOUT ZIN EXIT ENTER MENU Activates cursor on Sonar page Press up down left or right to move the cursor Zooms out the Sonar page Zooms in the Sonar page Press to return to a previous screen clear data and close menus Press to save data change values and accept menu commands Accesses the features available on each page PAGES Press to bring up the Pages screen also press and hold to switch control between the panels and combo split screen pages FREQ Selects sonar frequency displayed on Sonar page LIGHT Press to turn the unit on adjust the backlight or place the unit in low POWER power standby mode Press and hold to turn the unit off NOTE The unit is set up for optimal automatic operation under most conditions For use in thick weeds or very deep lt a water and a number of other fishing situations a range of special Fishing Mode settings are available Consult the user s manual for more details Sonah Cursor depth Brush pile Cursor Fish arches il Depth 68 2ft 41 6 Amplitude Information at Range scale History b
2. aking it easier to distinguish the bottom from fish trees and other objects To turn Temperature Graph on off 1 From the Sonar page press the MENU key The Sonar menu will appear select View The View submenu will appear 2 From the View submenu select Depth Line and press ENTER to turn this feature on or off Amplitude Scope Shows sonar returns in real time To turn Temperature Graph on off 1 From the Sonar page press the MENU key The Sonar menu will appear select View The View submenu will appear 2 From the View submenu select Amplitude Scope and press ENTER to turn this feature on or off
3. ar scope cursor s position When the cursor is active on screen use the History bar to scroll the Sonar page back and view previous sonar returns When the cursor is on screen the sonar does not show real time sonar returns To adjust Sensitivity and Colorline 1 From the Sonar page press the MENU key The Sonar menu will appear From the Sonar menu select Adjust 2 The Sensitivity adjustment menu will appear Use the left and right arrows to make adjustments 3 To adjust Colorline use the up or down arrows to select the Colorline menu Use the left or right arrows to make adjustments To select a Sonar page Palette 1 From the Sonar page press the MENU key The Sonar menu will appear Select View in the Sonar menu to open the View submenu 2 Fromthe View submenu select Palette The Palette menu has 12 sonar screen categories including Grayscale Nightview and Iceview To select a Zoom Bottom Lock or Flasher split screen display 1 From the Sonar page press the MENU key The Sonar menu will A e E appear Select View to open the View isi MEEN requency 200kHz submenu Ping speed To a View Split No split z 2 From the View submenu select Split O con Tempel Bottom Lock to open the Split screen menu The perth riasher Split screen options are No split Zoom bars ys Fish ID Symbols Zoom Bottom Lock and Flasher ov e No Split displays full sonar screen e Zoom spl
4. its the display with a 2X zoom on the left a normal sonar view on the right e Bottom Lock splits the display with a 2X zoom on the left a normal sonar view on the right Keeps the bottom on the screen at all times e Flasher splits the display with a flasher style sonar on the left a normal sonar view on the right To view and control two Frequencies at once 1 Press PAGES to access the Pages screen From the Pages screen Sonar options select Sonar combo pages Fish ID Displays fish echoes as fish symbols instead of fish arches with or without depths To select Fish ID symbols and Depths 1 From the Sonar page press the MENU key The Sonar menu will appear select View The View submenu will appear 9 1142 ao H Mx ka u 2 From the View submenu select Fish ID o to open the Fish ID menu list From the Fish ID menu list select Symbols and press ENTER to display fish symbols To display fish symbol depths select Depths To view both select Both Temperature Graph Uses a red line graph with digital display at the top of the screen to illustrate changes in Temperature To turn Temperature Graph on off 1 From the Sonar page press the MENU key The Sonar menu will appear select View The View submenu will appear 2 From the View submenu select Temperature Graph and press ENTER to turn this feature on or off Depth Line Displays a dark line over the bottom surface m

Download Pdf Manuals

image

Related Search

Related Contents

Toshiba R410A Air Conditioner User Manual  『おうちでなかよしシアター アンパンマン』 10月25日(土)発売    Manual - PowerMeterStore.com  Eurofase CH-24KAS-05 Installation Guide    Rockbox user manual  Hunter-Pro 832/8144 & Captain 8 User Guide  BT 500 Cordless Telephone User Manual    

Copyright © All rights reserved.
Failed to retrieve file