1. SIXNET protects your investment in SIXNET systems with long term planned technology and our unique Protected Technology Policy We will continue to support the specified capabilities of standard SIXNET products for at least five years twenty years for Industrial Managed Switches We plan each product improvement and new feature to be upward compatible with existing designs and installations Our goals are to make each new software release bring new power to your SIXNET systems and have every existing feature applications program and data file continue to work We protect your investment even further with a liberal five year trade in policy Exchange standard products for upgraded versions of the same product to take advantage of new features and improvements at any time for five years A prorated trade in allowance will be given for your existing unit SIXNET protects your long term productivity with state of the art planned technology and continued support SIXNET Statement of Limited Warranty SIXNET manufacturer of SIXNET products warrants to Buyer that products except software manufactured by SIXNET will be free from defects in material and workmanship SIXNET s obligation under this warranty will be limited to repairing or replacing at SIXNET s option the defective parts within one year of the date of installation or within 18 months of the date of shipment from the point of manufacture whichever is sooner Products may be returned by Buyer o
2. Etherbus DC DC Converter Last Revised 11 Aug 09 Page 9 of 22 Etherbus Hardware Manual SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 4 Overview Etherobus Hardware Manual Power Wiring These industrial Ethernet devices can be powered from the same DC source typically 24 VDC or 48 VDC that is used to power your other devices Refer to the details below on how to properly wire power to or from your Etherbus devices When tightening the screws be careful to tighten to a maximum torque of 3 48 Ib in The Etherbus switch accepts power in the range of 10 to 56 VDC 48 VDC nominal and can source 48 VDC power to four PoE devices For PoE sourcing PSE operation the power must be in the range of 45 to 56 VDC Otherwise the switch will function properly as an industrial Ethernet switch but will not source any PoE power For PoE operation make sure your 48 VDC supply is rated for at least 16 Watts per PoE channel being sourced plus some overhead for the switch It is recommended that a supply with 75 Watts or more of power be used The Etherbus switch supports dual power inputs allowing you to connect a backup power source The backup power should have the same voltage as the primary power Make your power connections as shown in the diagram below The PoE ports when sourcing power will put out 48 VDC see note below over the signal pair of the RJ45 connec
3. not covered under our warranty You will not be billed if the repair is covered under warranty Please supply us with as many details about the problem as you can The information you supply will be written on the RMA form and supplied to the repair department before your unit arrives This helps us to provide you with the best service in the fastest manner Normally repairs are completed in two days Sometimes difficult problems take a little longer to solve If you need a quicker turnaround ship the unit to us by air freight We give priority service to equipment that arrives by overnight delivery Many repairs received by mid morning typical overnight delivery can be finished the same day and returned immediately We apologize for any inconvenience that the need for repair may cause you We hope that our rapid service meets your needs If you have any suggestions to help us improve our service please give us a call We appreciate your ideas and will respond to them For Your Convenience Please fill in the following and keep this manual with your SIXNET system for future reference P O Date Purchased Purchased From To obtain support for SIXNET products Latest product info http www sixnet com Phone 1 518 877 5173 Fax 1 518 877 8346 E mail support sixnet com Address SIXNET Technology Park 331 Ushers Road Ballston Lake NY 12019 Etherbus Hardware Manual Page 22 of 22 Last Revised 11 Aug 09 SIXNET Techno
4. over Cable Wiring Standard Ethernet Plug amp Connector Pin Positions RJ45 Cable The maximum cable length for 10 100 1000BaseT with Cat 5E twisted pair cables is Distance typically 100 meters 328 ft Etherbus Hardware Manual Page 15 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Fiber Wiring Guidelines DITTO 94 Operation Network Device Check Verifying Connectivity The Etherbus industrial Ethernet PoE switch optionally has one 100 Mbps 100Base FX multimode or singlemode fiber ports The maximum segment length is up to 120 km or more depending on the type of fiber optic transceiver installed in the switch Refer to the technical specifications for details Or contact SIXNET for the available fiber optic transceivers Each fiber optic port on the switch is comprised of a pair of SC or ST style connectors For each fiber port there is a transmit TX and receive RX signal When making your fiber optic connections make sure that the transmit TX port of the switch connects to the receive RX port of the other device and the receive RX port of the switch connects to the transmit TX port of the other device Use standard fiber optic wiring techniques not covered by this manual to make your connections The corresponding ACT LNK LED will be ON solid when you have made a proper connection See images belo
5. 0BaseT 10 Mbps and n 100BaseT 100 Mbps on the RJ45 ports Each of PoE Switch these ports will independently auto sense the speed and duplex allowing you to interface to fast 100 i Mbps Ethernet devices or legacy 10 Mbps Optionally you can also have a 100BaseF 100 Mbps fiber optic port PoE Switch The Etherbus industrial Ethernet PoE switch provides connections to standard Ethernet devices such as PLCs Ethernet I O industrial computers and much more Two types of Overview communication ports may be found on these switches RJ45 copper Ethernet ports or fiber optic Ethernet ports Switch RJ45 Use data quality not voice quality twisted pair cable rated category 5 or better with S standard RJ45 connectors For best performance use shielded cable Straight through or Port Wiring crossover RJ45 cable can be used regardless of the device the switch is to be connected to as all the ports are capable of auto mdi mdix crossover detection The RJ45 Ethernet port connector bodies on these products are metallic and are connected to the Chassis GND terminal Therefore shielded cables may be used to provide further protection To prevent ground loops the cable shield should be tied to the metal connector body at one end of the cable only Electrical isolation is also provided on the Ethernet ports for increased reliability For Reference Straight thru Cable Wiring Only Either cable wiring will work Cross
6. 8V 2 EB PSE 24V 1 EB PD 24V 1 EB PS 4824 13 These industrial Ethernet devices meet the following standards plus others Electrical safety UL 508 CSA C22 EN61010 1 IEC1010 Emissions FCC part 15 ICES 003 EN55022 Class B Immunity 1EC61326 1 Hazardous locations UL 1604 CSA C22 2 213 Class 1 Div 2 Groups A B C D Cenelec EN50021 and ATEX Zone 2 Install the Managed Switches in accordance with local and national electrical codes Lightning Danger Do not work on equipment during periods of lightning activity Do not connect a telephone line into one of the Ethernet RJ45 connectors Etherbus Hardware Manual Page 3 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 2 LED Indicators The Etherbus devices have several LEDs to indicate the power and operational status of the unit See below for the location of these LEDs and an explanation of their operation EB 5ES PSE 1 EB 5ES PSE 2ST EB PSE 48V 2 a S Ai EB PSE 24V 1 EB PD 24V 1 EB PS 4824 13 Typical LED Location for Etherbus Products Note The LED locations may vary slightly from these images Etherbus Hardware Manual Page 4 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Power LED On all models except the splitter there is one p
7. ATEX Cenelec Zone 2 EMC emissions and immunity _ EMC emissions and immunity FCC Part 15 ICES 003 EN55022 IEC61326 1 Miscellaneous Dims w x h x d approximate 25 x 101 x 76 mm 1 0 x 4 0 x 3 0 inches Protection Standards Etherbus Hardware Manual Page 21 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 7 Service Information Product Support Service Information We sincerely hope that you never experience a problem with any SIXNET product If you do need service call SIXNET at 518 877 5173 and ask for Applications Engineering A trained specialist will help you to quickly determine the source of the problem Many problems are easily resolved with a single phone call If it is necessary to return a unit to us an RMA Return Material Authorization number will be given to you SIXNET tracks the flow of returned material with our RMA system to ensure speedy service You must include this RMA number on the outside of the box so that your return can be processed immediately The applications engineer you are speaking with will fill out an RMA request for you If the unit has a serial number we will not need detailed financial information Otherwise be sure to have your original purchase order number and date purchased available We suggest that you give us a repair purchase order number in case the repair is
8. _ Sixnet Etherbus EB Series z Industrial Ethernet PoE Switch i Injectors Splitter and More I USER MANUAL Hardware Guide Contents at a Glance Section 1 General Information ccccccceeeeeeeee eee neeeeeeenneeeeeennaaes Page 3 Section 2 LED Indicators sac sdce cones ceeds eateeensddece canter ncecaeesibnenasedssecedss Page 4 Section 3 Installation MOUNTING cc ceeee ee eeeee eee eeeeeeeeneeeeeeees Page 6 Section 4 POWOF VININ i icctapeetetcraddsouetusensaienuasetecnaiiemetaseueniseuetuess Page 10 Section 5 Communication Wiring cccceeseeeeeneeeeeeeenneceeeeeneaeens Page 15 Section 6 Technical Specifications cirscesceeccdvesccenevnctyieesenecuiancestconcsi Page 18 Section 7 Service Information aaannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Page 22 This manual applies to the following products e EB 5ES PSE Industrial PoE 5 port unmanaged Ethernet switch EB PSE 48V 2 Industrial PoE power injector for 2 channels EB PSE 24V 1 Industrial PoE power injector with built in 24V to 48V converter EB PD 24V 1 Industrial PoE splitter converts 48V to 24V EB PD UPS 1 Industrial PoE splitter converts 48V to 14V EB PS 4824 13 Industrial DC DC power converter for 48V to 24V Etherbus Hardware Manual Page 1 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com SIXNET Protected Technology Policy
9. cing PoE power will put out 48 VDC see note below over the signal pair of lines in the RJ45 connection o V on RX lines 1 and 2 o V on TX lines 3 and 6 o Lines 4 5 7 and 8 are unused EB PSE 48V DC Power Input 7 Ds DS oy S Y e Chassis GND oe panel DC Supply 45 56 VDC Note When the supply voltage is 45 to 47 VDC then the power output for the PoE will be the same as the supply voltage For example if the supply voltage is 45 VDC then the PoE output will also be 45 VDC If the supply voltage is 48 to 56 VDC then the PoE output will be regulated at 48 VDC Etherbus Hardware Manual Page 11 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com The Etherbus Single Injector has a built in DC to DC converter allowing it to accept power in the range of 18 to 30 VDC 24 VDC nominal and source 48 VDC power to one PoE device Make sure your 24 VDC supply is rated for at least 20W Make your power connections as shown in the diagram below Single Injector Power There are two models of this injector The standard 1A model when sourcing PoE power will put out 48 VDC over the unused pair of lines in the RJ45 connection o V on lines 4 and 5 o V on lines 7 and 8 o TX on lines 3 and 6 o RX on lines 1 and 2 The 1B model special order when sourcing PoE power will put out 48 VDC o
10. contact SIXNET 5 us frame time Varies on load 1024 and 3 2 Gbps Redundant input terminals 10 30 VDC with no PoE output Power i ith lari ower input with reverse polarity protection 45 56 VDC for PoE output Switch power consumption 2 0 W 5 port without fiber PoE typical all ports active at 100 Mbps 3 0 W 5 port with 1 fiber PoE Power input transient protection Power input spike Protection 5 000 watts 10 times for 10 uS PoE operation Auto power management PoE disconnect mode DC disconnect PoE auto detection Per IEEE 802 2af PoE protection Over temperature over current over under voltage and transient Environmental Truly industrial design Operating temperature range 40 to 75 C cold startup 40 Storage temperature range 40 to 85 C Humidity non condensing 5 to 95 RH Vibration shock and freefall IEC68 2 6 27 and 32 UL508 CSA C22 2 14 CUL EN61010 1 CE FCC Part 15 ICES 003 EN55022 IEC61326 1 UL1604 CSA C22 2 213 CUL Class 1 Division 2 ATEX Cenelec Zone 2 Eye safety fiber models IEC60825 1 Class 1 FDA 21 DIN rail or direct to panel mounting Polycarbonate with IP30 protection Packaging material amp protection Weight approximate 0 17 Kg 0 25 Ibs Dimensions H x W x D approximate 4 x 1x 3 3 10 x 2 5 x 8 3 cm MTBF estimated gt 1 000 000 hours Etherbus Hardware Manual Page 18 of 22 Last Revised 11 Aug 09 SIXNET Tech
11. e Make sure to allow enough room to route your Ethernet copper or fiber optic cables Recommended DIN rail mounting steps Hook top back of unit over the din rail 2 Push bottom back onto the din rail until it snaps into place DIN Rail Mounting Recommended DIN rail removal steps Insert screwdriver into din clip and pry until it releases from the din rail A B Unhook top of unit from din rail Sire Pe ie _ i Ly Oooo ea ET NNN NNN N WW WO W S WN Hi ih OND J LET ili ia Page 6 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Etherobus Hardware Manual 0 40 1 02 cm Snaps to standard 2 90 D IN rail EN50022 Removable gl any Screw Block ypical tor a 4 SC or ST fiber 7 35 cm 35 mm i a 1 01 a eX 5 02 cm ane 4 20 Dia 0 15 3 95 L f 0 38 cm lt 10 03 cm
12. i i Use for direct N panel mounting g to a flat surface gt 1 98 _ AAAAAAAAA L oI 5 02 cm T 2 57 cm T 1 00 P 3 26 Jo t 0 06 2 54 cm EB 5ES PSE 8 28 cm 0 15 cm Mechanical Dimensions for the Etherbus Switch Snaps to standard gemovable EB PSE 48V 2 90 DIN rail EN50022 7 35 cm 35 mm l 1 01 i o n 2 57 em 4 gg oy i 5 02 cm 4 20 Dia 0 15 3 95 DE 110 67 cm 0 38 cm lt 10 03 cm __ Use for direct panel mounting _ to a flat surface La 1 98 i a L rae 5 02 cml oe 2 57 cm T 1 00 3 26 0 06 2 54 cm g 8 28 cm 0 15 cm Mechanical Dimensions for the Etherbus Dual Injector Etherbus Hardware Manual Page 7 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Removable EB PSE 24 V Screw Block A O 3 95 al 4 20 10 03 cm 10 67 cm l 1 00 a 2 54 cm Snaps to standard 2 90 DIN rail EN50022 7 35 cm m 35 mm 1 01 yr 5 02 cm ay Dia 0 15 0 38 cm lt Use for direct panel mounting _ toa flat surface gt 1 98 2 57 cm 3 26 0 06 8 28 cm 0 15 cm Mechanical Di
13. logy Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com
14. m below EB PD UPS DC Power Output DSSS HH fT Optional aid 12V Battery panel 12 14 VDC Load Etherbus Hardware Manual Page 13 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com DC DC The Etherbus DC to DC converter accepts power in the range of 45 to 56 VDC and outputs an isolated and regulated 24 VDC 13 watts This convenient accessory allows you to power typical 24 VDC industrial devices from your 48 VDC system power Make your input and output power connections as shown below Converter Power 24 _ 4 45 56 VDC VDC Output F Input EB PS 4824 13 Power Connections Etherbus Hardware Manual Page 14 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 5 Communication Wiring Unlike an Ethernet hub that broadcasts all messages ee i out all ports the Etherbus industrial Ethernet PoE e Operation switch will intelligently route Ethernet messages only out the appropriate port The major benefits of this are increased bandwidth and speed reduction or elimination of message collisions and deterministic performance when tied with real time systems aed The switch can support 1
15. mensions for the Etherbus Injector with DC DC Converter Removable Screw Block EB PD xxx A 3 95 4 20 10 03 cm 10 67 cm 1 00 2 54 cm Etherbus Hardware Manual SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Snaps to standard 2 90 DIN rail EN50022 7 35 cm E 35 mm o OOOO 1 01 oy 5 02 cm Dia 0 15 0 38 cm lt Use for direct _ panel mounting to a flat surface 7 1 98 TA 1 01 5 02 cm 2 57 cm 3 26 0 06 8 28 cm 0 15 cm Page 8 of 22 Mechanical Dimensions for the Etherbus Splitter Last Revised 11 Aug 09 Snaps to standard DIN rail EN50022 Removable EB PS 48 24 1 3 e Screw Block EE 35 mm 7 35 cm A 1 01 ot A a oy i 5 02 cm 4 20 Dia 0 15 3 95 110 67 cm 0 38 cm lt 10 03 cm Use for direct _ panel mounting to a flat surface N in 1 98 g 2 57 cm 1 00 a 3 26 J t 0 06 ee 8 28 cm 0 15 cm 2 54 cm Mechanical Dimensions for the
16. n is detected OFF o No fiber connection is detected PoE LED This is the Green LED that is either integrated into the RJ45 port on switch models or is below the PoE ports on injector models It indicates the PoE status of the port ON green A valid Powered Device PD is detected and the switch or injector is g sourcing power on this port OFF o No valid Powered Device PD is detected so no power is being sourced No valid Powered Device PD is detected or the connected device is drawing too little current lt 10 mA so no power is being sourced However the switch or injector is periodically looking for a valid device This condition may occur when you have connected a PoE Periodically Blinks ON splitter but it has not been connected to a load yet Once the connected device such as a splitter is loaded and draws more than 10 or 15 mA then power will be sourced Error Code Some models may blink an error code If you see the same sequence Blink of blinks repeatedly then contact SIXNET for more information Etherbus Hardware Manual Page 5 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Installation Section 3 These industrial Ethernet PoE devices can be snapped onto a standard DIN rail EN50022 or screwed directly to a flat panel Refer to the mechanical drawings below to properly mount Overview your switch Not
17. nd receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Copyright amp Trademarks Etherbus is a registered trademark of SIXNET LLC Copyright 2007 SIXNET LLC All Rights Reserved Note All information in this document is subject to change without notice Etherbus Hardware Manual Page 2 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 1 Overview Reference Images Safety Standards General Information This manual will help you install and maintain these Etherbus industrial Power over Ethernet PoE devices These devices support standard IEEE 802 3af Power over Ethernet PoE and will work with any device that also supports this standard Installation of the Etherbus devices Is very easy and they will begin to operate as soon as they are powered up For all models there are no user settings so they are truly plug and play The following products are covered by this manual EB PSE 24v 1 Injector 24voo avee 1 o Ee PO24v 1 Splitter 4eVPoE avoe 1 EB PO UPS 1 Spliter 4eVPoE avoe 1 IEB PS 4824 13 Converer 4eVOC avoe Key PD Powered Device accepts 48V PoE power PSE Power Sourcing Equipment puts out 48V PoE power EB 5ES PSE 1 EB PSE 4
18. nly after permission has been obtained from SIXNET Buyer will prepay all freight charges to return any products to the repair facility designated by SIXNET This limited warranty does not cover losses or damages which occur in shipment to or from Buyer or due to improper installation maintenance misuse neglect or any cause other than ordinary commercial or industrial applications In particular SIXNET makes no warranties whatsoever with respect to implied warranties of merchantability or fitness for any particular purpose All such warranties are hereby expressly disclaimed No oral or written information or advice given by SIXNET or SIXNET s representative shall create a warranty or in any way increase the scope of this warranty This limited warranty is in lieu of all other warranties whether oral or written expressed or implied SIXNET s liability shall not exceed the price of the individual units which are the basis of the claim In no event shall SIXNET be liable for any loss of profits loss of use of facilities or equipment or other indirect incidental or consequential damages INSTALLATION AND HAZARDOUS AREA WARNINGS These products should not be used to replace proper safety interlocking No software based device or any other solid state device should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety In particular SIXNET disclaims any responsibility for damages either direct or conseq
19. nology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Etherbus Injector Performance Specifications General Industrial PoE Injectors S Power Sourcing Equipment PSE 24V model only derate 1W per 2 C after 60 C RJ45 PoE pin assignments A unused pair A TX 3 6 RX 1 2 V 7 8 V 4 5 B signal pair B TX V 8 6 RX V 1 2 PoE protection Power Input Power input for 48V 2 models Power input for 24V 1 models PoE transient protection PoE spike protection 5 000 watts 10 times for 10 uS Environmental Operating temperature range 40 to 75 C cold startup 40 see PoE power derating above Storage temperature range Humidity non condensing 5 to 95 RH Vibration shock and freefall UL508 CSA C22 2 14 CUL EN61010 1 CE FCC Part 15 ICES 003 EN55022 IEC61326 1 UL1604 CSA C22 2 213 CUL Class 1 Division 2 ATEX Cenelec Zone 2 DIN rail or direct to panel mounting Packaging material and protection Polycarbonate with IP30 protection Weight approximate 0 17 Kg 0 25 lbs Dimensions H x W x D approximate 4 x 1x 3 3 10 x 2 5 x 8 3 cm MTBF estimated gt 1 000 000 hours Etherbus Hardware Manual Page 19 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Mode Ethernet protocols supported All IEEE 802 3 Ethernet ports Ethernet p
20. ort standards IEEE 802 3af PoE operation PoE Power input range Automatic detection and classification power is accepted on either the signal or unused pairs PoE power input PoE protection PoE transient protection PoE spike protection Power Output 24 VDC 0 54 Amps 24V model Voltage output 14 VDC 0 93 Amps UPS model Power output Environmental Operating temperature range Storage temperature range Humidity non condensing Vibration shock and freefal Electrical safety UL508 CSA C22 2 14 CUL EN61010 1 EMC emissions and immunity CE FCC Part 15 ICES 003 EN55022 IEC61326 1 Hazardous locations UL1604 CSA C22 2 213 CUL Class I Division 2 ATEX Cenelec Zone 2 DIN rail or direct to panel mounting Packaging material and protection Polycarbonate with IP30 protection Weight approximate 0 17 Kg 0 25 lbs Dimensions H x W x D approximate 4 x 1x 3 3 10 x 2 5 x 8 3 cm MTBF estimated gt 1 000 000 hours Etherbus Hardware Manual Page 20 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Etherbus DC DC Converter Performance Specifications Output Over voltage Transient 15Kw peak Surge 5K watts 10x10 uS ES uiOninGhial Operation humidity 5 to 95 RH non cond Safety sts lt CSstiCtw UL508 CSA C22 2 14 CUL EN61010 1 Hazardous locations CE UL1604 CSA C22 2 213 CUD Class 1 Division 2
21. ower LED that is ON if either power input P1 or P2 has valid power applied to it If the power LED is OFF then no power is being applied to the unit On the splitter the power LED will be ON when PoE power is detected on the incoming Ethernet line It will be OFF if no PoE power is detected This is the Yellow LED in the RJ45 ports of the Etherbus switch model EB 5ES PSE It ACT LNK a hae indicates the Link and Activity status of the port ON yellow Indicates that there is a proper Ethernet connection Link between y the port and another Ethernet device but no communications activity not flashing is detected Indicates that there is a proper Ethernet connection Link between ON yellow the port and another Ethernet device and that there is flashing communications activity Indicates that there is not a proper Ethernet connection Link between the port and another Ethernet device Make sure the cable has been plugged securely into the ports at both ends This is the Green LED in the RJ45 connector of Port 5 on the Etherobus switch model EB Speed 10 100 5ES PSE 1 It indicates the Speed of the uplink port ON green A100 Mbps 100BaseT connection is detected OFF o A 10 Mbps 10BaseT connection is detected Fiber Optic This is the Green LED above the fiber port on the Etherbus switch model EB 5ES PSE 2 or 3 It indicates the Link status of the fiber optic port ON green A100 Mbps 100BaseF connectio
22. rnet switch or router Then connect the cable to be run to your PoE Powered device PD to the PoE OUT port The PoE LED will be ON when power is being sourced to your device The Etherbus industrial Ethernet PoE splitter has two RJ45 ports See the diagram below One RJ45 port is labeled PoE IN for PoE input and the other is labeled ETH OUT for Ethernet output Connect the cable from your PoE PSE switch or injector to the PoE IN port Then connect the cable to be run to your standard Ethernet non PoE device to the ETH OUT port which does not have any power on it Etherbus Hardware Manual Page 17 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Section 6 Technical Specifications Here are the hardware technical specifications for the products covered by this manual Technical Please contact SIXNET if additional information is required Specs All specifications are subject to change without notice Etherbus Switch Performance Specifications General sUnimanaged store amp forward o 100BaseF 100 Mbps full duplex Fiber multimode mm typical 50 or 62 5 125 um SC or ST Fiber singlemode sm typical 9 or 10 125 um SC or ST Fiber max distance full duplex see web for more details Typ latency for 100 Mbps ports MAC addresses and bandwidth Power In and PoE Out 4 km mm 20 sm or 40 km long haul or more
23. tion o V onRX lines 1 and 2 o V on TX lines 3 and 6 o Lines 4 5 7 and 8 are unused EB 5ES PSE Single DC Power P2 Pi _ EN K EB 5ES PSE Dual DC Power P2 Pl _ QOOC gt 1 o Chassis FA _ Chassis Gd GND BND lt panel u panel Two DC Supplies 10 56 VDC One DC Supply 10 56 VDC Note When the supply voltage is 45 to 47 VDC then the power output for the PoE will be the same as the supply voltage For example if the supply voltage is 45 VDC then the PoE output will also be 45 VDC If the supply voltage is 48 to 56 VDC then the PoE output will be regulated at 48 VDC Page 10 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com Dual Injector Power The Etherbus Dual Injector accepts power in the range of 45 to 56 VDC 48 VDC nominal and can source 48 VDC power to two PoE devices Make sure your 48 VDC supply is rated for at least 16 Watts per PoE channel being sourced Make your power connections as shown in the diagram below There are two models of this injector The standard 2A model when sourcing PoE power will put out 48 VDC see note below over the unused pair of lines in the RJ45 connection o V onlines 4 and 5 o V onlines 7 and 8 o TXonlines 3 and 6 o RX on lines 1 and 2 The 2B model special order when sour
24. uential that result from the use of this equipment in any application All power input and output I O wiring must be in accordance with Class Division 2 wiring methods and in accordance with the authority having jurisdiction WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 EXPLOSION HAZARD DIVISION 2 ZONE 2 WARNING WHEN IN HAZARDOUS LOCATIONS DISCONNECT POWER BEFORE EXPLOSION HAZARD REPLACING OR WIRING UNITS WARNING DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED EXPLOSION HAZARD OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment a
25. ver the signal pair of lines in the RJ45 connection o V on RX lines 1 and 2 o V on TX lines 3 and 6 o Lines 4 5 7 and 8 are unused EB PSE 24V EB PSE 24V Single DC Power Dual DC Power P2 Pl _ P2 Pl _ yy Os oe YA CY CS o Chassis e a Chassis WY panel ae panel One DC Supply Two DC Supplies 18 30 VDC 18 30 VDC Etherobus Hardware Manual Page 12 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com The Etherbus Splitter accepts 48 VDC from a PoE line and outputs an isolated and regulated 24 VDC 13 Watts to power your standard Ethernet non PoE devices Just connect your incoming PoE line Supports both power over the signals lines or power over the unused lines to the PoE IN port The splitter will convert the 48 VDC to 24 VDC and make it available on the pluggable screw terminal block Make your power connections as shown in the diagram below EB PD 24V DC Power Output OO CES Chassis p GND panel 24 VDC Load The UPS model special order is the same as above but outputs 14 VDC instead of 24 VDC The 14 VDC can be used to power 12V or 14V devices and it can be used to charge a 12V seal lead acid battery for power backup Make your power connections as shown in the diagra
26. w for typical fiber optic port placement Typical Typical SC Style ST Style Connector Connector The RJ45 ports will auto sense for Full or Half duplex operation while the fiber port is configured for full duplex operation Note Fiber devices with half duplex settings should still communicate with the switch If otherwise then please contact SIXNET These industrial Ethernet switches are capable of supporting 10 100BaseT on the RJ45 Copper ports and 100BaseF on the fiber optic ports Make sure you connect the appropriate devices to each port After all Ethernet and or fiber connections are made check the LED s corresponding to the ports that each of the devices are connected to Ensure that for each port that is in use the LED is on or blinking If a port LED is off go back and check for connectivity problems between that port and the network device connected Etherbus Hardware Manual Page 16 of 22 Last Revised 11 Aug 09 SIXNET Technology Park e 331 Ushers Road e Ballston Lake NY 12019 e USA e 1 518 877 5173 e support sixnet com PoE Injector RJ45 Wiring PoE Splitter RJ45 Wiring The Etherbus industrial Ethernet PoE injectors have two RJ45 connectors per PoE channel See the diagram below One RJ45 port is labeled as ETH IN for Ethernet Input and the other is Labeled as PoE OUT for PoE Output Connect your standard Ethernet non PoE cable to the ETH IN port This cable is typically coming from an Ethe