Home

YSS1000 Setting Software Installation Manual

image

Contents

1. Read Me First WG Series YSS1000 Setting Software Installation Manual F ancfjonal nt gonane na IM 01B08K02 01EN vigilantplant YOKOGAWA IM 01B08K02 01EN Yokogawa Electric Corporation 2nd Edition Product Registration Thank you for purchasing YOKOGAWA products YOKOGAWA provides registered users with a variety of information and services Please allow us to serve you best by completing the product registration form accessible from our homepage http www yokogawa com ns reg Contents FONG WONG SEAT MA maranga AA AA AA AA PAA 2 NOUCE NAAN NA uments new AAA AAA AAA AAA AA AAA AAA AAA 2 WAAMA AA WA NLNG NN DNA NAA AA ANA ANNA 2 REVISIONS pana na nA NG IN GEN NA AA ADAN NN BA ANN ANA NANA AA 2 Handling Precautions Tor the Main UM AA 3 Notes on Using the YSS1000 Setting SOmWane sisson wai nG AGANG NEEE ANAN KAKANAN 3 SYMBOLS SS ct MMS AMA eee Kama ect n EE a eee Aa 4 Aboutam Electronic Manual wA MANA NANANA ANAN cae ed Kakai suid yas kawa singe AA 4 License Agreement for Package Software Product w0mmmamzaman manana nana anza na nza ana nana asan 6 Checking the Contents of the Package mna aan amaan n manaa maana waana wanawa ANNA 9 CD Handling GA aa 10 Operating Environment GG BAKANTENG 11 Installing USB Converter Driver Software a 12 Installing USB Converter Driver Software NMI MCE NS Leal AUN west eects AA ANA AA AA NAA AA AA AA Uninstalling USB Converter
2. a IM 01B08K02 01EN 15 Installing USB Converter Driver Software Verifying Installation Operating procedures 7 From the Start menu of Windows select Control Panel gt Device manager Note From the Start menu of Windows select Control Panel gt System and Maintenance gt Device manager if the control panel s display method is Control Panel Home 2 The User Account Control screen appears Click Continue 3 Verify that the virtual COM port driver 1 YOKOGAWA USB Serial Port COMn is displayed under Ports COM amp LPT as COM port and the USB device driver 2 YOKOGAWA USB Serial Converter A1053UR is displayed under Universal Serial Bus controllers File Po View Help e m A ml a COM amp LPT inter Port LPT1 Processors DP Security Devices Ha Sound video and game controllers lt gt Storage controllers Hi System devices Universal Serial Bus controllers Generic USB Hub Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB Universal Host Co Intel R 82801G ICH7 Family USB2 Enhanced Host C USB Composite Device 7 USB Mass Storage Device 9 v g USB Root Hub USB Root Hub USB Root Hub USB Root Hub USB Root Hub YOKOG
3. Manual IM 01B08D02 02EN This manual describes the detailed functions and setting items It does not contain the communication functions YS1350 YS1360 Operation Guide IM 01B08E02 01EN This manual describes the basic operation methods YS1350 YS1360 User s Manual IM 01B08E02 02EN This manual describes the detailed functions and setting items It does not contain the communication functions YS1000 Series Communication Interface User s Manual This manual describes how to use YS1000 in Ethernet serial and DCS LCS communications YSS1000 Installation Manual IM 01B08J02 01EN IM 01B08K02 01EN This is identical to the printed manual YSS1000 Setting Software YS1700 IM 01B08K02 02EN Programmable Function User s Manual This manual describes how to use YSS1000 and YS1700 s programmable function YS1000 Series Replacement Manual IM 01B08H02 01EN This manual describes the compatibility of installation and wiring with YS100 YS80 EBS I EK HOMAC and 100 line User s manuals for YS1000 are available on the following web site www yokogawa com ns ys im You need Adobe Reader 7 0 or later but the latest version is recommended installed on the computer in order to open and read the manuals 2nd Edition May 2015 YK All Rights Reserved Copyright 2014 Yokogawa Electric Corporation O D Notice e The contents of this manual are subject to change without notice as a result of continuing impr
4. Yokogawa fails to take either of the countermeasures set forth in a through c above Yokogawa shall indemnify you only by paying back the price amount o the Package Software Product which Yokogawa has already received 8 Limitation of Liability If and when you should incur any damage relating to the Package Software Product Yokogawa provided to you under this Agreement due to the reason attributable to Yokogawa Yokogawa shall take actions in accordance with this Agreement However in no event shall Yokogawa be responsible for any indirect damage consequential damage punitive damage and or special damage including without limitation loss of operational profit loss of interruption of your business and loss of business information and that Yokogawa s liability to your damage shall not exceed the price amount of the Package Software Product Yokogawa received It is specifically agreed by both parties that Yokogawa shall be released and discharged from part or any and all of the liability and responsibility under this Agreement if you including the case you have any third party undertake to modify remodel combine with other software or products or cause any deviation from the basic specifications or functional specifications withou Yokogawa s prior written consent 9 Term This Agreement shall become effective from the date when you receive the Package Software Product and continues in effect unless or until early terminated as provide
5. and games lor run program eneral options Kk Open folder to view files using Windows Explorer Set AutoPlay defaults in Control Panel 3 Click YSS1000 Installation 18 IM 01B08K02 01EN Installing YSS1000 Setting Software 4 The User Account Control screen appears Click Allow Don t run the program unless you know where it s from or you ve used it before Fi setup exe Unidentified Publisher gt Cancel I don t know where this program is from or what it s for gt Allow Itrust this program I know where it s from or I ve used it before Y Details User Account Control helps stop unauthorized changes to your computer 5 To continue follow the message given in each dialog box Welcome to the YSS1000 Setup Wizard a The installer will guide you through the steps required to install Y551000 on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel Bact The user specification can be selected while installing the YSS1000 When you install the YSS1000 after Everyone is selected even if other users log in it is possible to start YSS1000 from the Start menu gt Programs When you install the YSS1000 after Just
6. and the AutoPlay screen appears click Run startup exe to display the start up screen Ger 7 TA fale 8 DVD CD RW Drive D YSS1000 F Always do this for software and games Install or run program General options L Open folder to view files using Windows Explorer Set AutoPlay defaults in Control Panel 12 IM 01B08K02 01EN Installing USB Converter Driver Software 3 Click USB Driver Installation vigilantplant Te tee path a roth ncaa USIN series mmm NW if you use the USB interface install the USB driver on your PC For details refer to the installation manual 4 The User Account Control screen appears Click Continue f User Account Contr O x If you started this program continue YOKOGAWA A1053UR Installer Yokogawa Electric Corporation 5 Installshield Wizard screen appears Click Next ee YOKOGAWA A1053UR Installer InstallShield Wizard Welcome to the InstallShield Wizard for YOKOGAWA A1053UR Installer The InstallShield Wizard will install YOKOGAWA A1053UR Installer on your computer To continue click Next SI D a US 5 se Baile ae FO So KIS 02 a Sy IM 01B08K02 01EN 13 Installing USB Converter Driver Software 6 Click Install YOKOGAWA A1053UR Installe Ready to Install the Program The wizard is ready to begin installation InstallShield Click Install to beg
7. grounding are suspected to be defective do not operate the instrument Ensure that all protective functions are in working order before operating the instrument e Do Not Use in an Explosive Atmosphere Do not operate the instrument in locations with combustible or explosive gases or steam Operation in such environments constitutes an extreme safety hazard Use of the instrument in environments with high concentrations of corrosive gas H2S SOx etc for extended periods of time may cause a failure e Do Not Remove Internal Unit The instrument s case should not be removed by anyone other than YOKOGAWA s service personnel There are dangerous high voltage parts inside e External Connection Ensure that protective grounding is connected before connecting the instrument to the device under measurement or to an external control circuit e Damage to the Protective Construction Operation of the instrument in a manner not specified in this user s manual may damage its protective construction omm m Warning and Disclaimer YOKOGAWA makes no warranties regarding the product except those stated in the WARRANTY that is provided separately The product is provided on an as is basis YOKOGAWA assumes no liability to any person or entity for any loss or damage direct or indirect arising from the use of the product or from any unpredictable defect of the product m Notes on Software YOKOGAWA makes no warranties either expressed or
8. me is selected even if other users log in YSS1000 is not displayed in the Programs Confirm Installation The installer is ready to install Y551000 on your computer Click Next to start the installation Cancel lt Back a1eMyos 19 IM 01B08K02 01EN EF o oh WI gt Co lt n _ S 00 o B3 3 fo Installing YSS1000 Setting Software Installation Complete WA PK Y551000 has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework For installation of YSS1000 Setting Software follow the message given in each dialog box Verifying Installation From the Start menu of Windows point to Programs then YS1000 Series and verify that the YS1000 Series contains YSS1000 Uninstalling YSS1000 Setting Software From the Start menu of Windows select Control Panel gt Programs and Features gt YSS1000 and click Remove Note 1 From the Start menu of Windows select Control Panel gt Programs gt Programs and Features if the control panel s display method is Control Panel Home Note 2 The User Account Control screen appears Click Allow to uninstall YSS1000 20 IM 01B08K02 01EN YOKOGAWA YOKOGAWA ELECTRIC CORPORATION Headquarters 2 9 32 Nakacho Musashino shi Tokyo 180 8750 JAPAN Phone 81 422 52 5555 Branch Sales Offices Osaka Nagoya Hir
9. models similar to any of the following GNU s General Public License GPL or Lesser Library GPL LGPL the Artistic license e g PERL the Mozilla Public License the Netscape Public License the Sun Community source License SCSL the Sun Industry Source License SISL the Apache Software License and the Common Public License CPL or the Berkeley Software Development BSD 3 Limitation for Specific Uses 1 Unless otherwise agreed by both parties in writing the Package Software Product shall not be intended to be specifically designed manufactured or distributed for the purpose of operation of any aviation vessel support of those operations from the ground or for any design construction maintenance operation and or use of nuclear products and or facilities 2 Even if you use the Package Software Product for the purpose of preceding Article 3 1 Yokogawa disclaims any responsibilities warranties liabilities claims or damages whatsoever similar thereto arising out of the use or operations of the Package Software Product for such purpose and you shall indemnify and hold harmless Yokogawa including without limitation its officers employees sales representatives and their officers and employees from any claim suit demand damage and similar thereto including reasonable attorneys fees 4 Warranty 1 During the warranty period defined in this Article 4 4 below hereinafter called Warranty Period Yokogawa warrants
10. package software product without installing it to the seller or Yokogawa immediately 1 Grant of License 1 The terms and conditions of this Agreement shall apply to the following package software of Yokogawa herein after referred to as Package Software Product Product YSS1000 Parameters Setting Tool and materials related thereto that Yokogawa designates Number of license One 1 2 The Package Software Product herein shall include without limitation a software program font data base data put into fill in the form instruction manual functional specifications materials related thereto image photograph animation video image sound music text all of which are incorporated into software component program and applet applet means software component program incorporated into text or icon 2 Terms and Conditions of License 1 Yokogawa grants you for the purpose of your own use non exclusive and non transferable license of the Package Software Product on designated computer agreed by both parties in consideration of the license fee agreed separately by the both parties 2 You are unless otherwise agreed in writing by Yokogawa not entitled to sell lend distribute transfer or sublicense or if any pledge the Package Software Product You shall not use Package Software Product on other computer than the designated one through wide area network either including but not limited to intranet internet local area ne
11. such an event contact your sales representative Notes on Using the YSS1000 Setting Software Please update the YSS1000 Setting Software to the latest version Download it from the following URL URL http www yokogawa com ns ys im If the YS1000 s suffix code Use is 1 or 2 use YSS1000 version R3 01 01 or later IM 01B08K02 01EN Symbols Used in This Manual A This symbol is used on the instrument It indicates the possibility of injury to the user or damage to the instrument and signifies that the user must refer to the user s manual for special instructions The same symbol is used in the user s manual on pages that the user needs to refer to together with the term WARNING or CAUTION WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user and indicates precautions that should be taken to prevent such occurrences CAUTION Calls attention to actions or conditions that could cause injury to the user or damage to the instrument or property and indicates precautions that should be taken to prevent such occurrences Note Identifies important information required to operate the instrument Indicates related operations or explanations for the user s reference Indicates a character string displayed on the display Setting Display Indicates a setting display and describes the keystrokes required to display the relevant settin
12. that the Package Software Product shall properly function in accordance with the Instruction Manual or Functional Specifications of Yokogawa on the hardware under the environmental or other onditions designated by the vendor of such hardware or by Yokogawa However in no event shall Yokogawa warrant the following under any operating environment and circumstance The Package Software Product a will never be interrupted b will never be free from defect c will be completely corrected d will be free from any cross interference such as cross conflict with other software program e will satisfy your or your customer s any particular and or prospective purpose f will be accurate correct reliable or most up dated 2 During the Warranty Period if the Package Software Product fails to operate in accordance with the steps of the instruction manual or functional specifications attributable to Yokogawa or if defect s such as damage of a media of the Package Software Product attributable to Yokogawa is found Yokogawa agrees to either repair or replace free of charge any Package Software Product which shall be returned to Yokogawa s nearest authorized service facility immediately at your expense where delivery point hereunder of the Package Software Product is outside of Japan re import tax and other charges shall be also borne by you Further in the case that repair or replacement of the Package Software Product requires additional works such as load
13. 2 a l Do you want to completely remove the selected application and all of its features 6 The Uninstall Complete screen appears Click Finish You have completed uninstalling the driver software IM 01B08K02 01EN 17 Installing YSS1000 Setting Software CAUTION Install the software as an administrator Do not set YSS1000 user file save directory in Program Files folder The YSS1000 will not work properly Also if YSS 1000 user file save directory is set in Program Files folder on Windows XP personal computer do not upgrade its OS to Windows 7 Windows 8 1 Before installing YSS1000 Setting Software quit all running applications e Avoid entering just the drive as the installation location such as CA Enter the full directory path e When reinstalling YSS1000 uninstall the installed YSS1000 first and then reinstall YSS1000 Installing YSS1000 Setting Software Operating procedures 7 Start Windows Z e Insert the CD of YSS1000 into the CD ROM drive The start up screen appears automatically ASIDO series maw NS Mf you use the USB interface install the USB driver on your PC YOKOGAWA For details refer to the installation manual Note If the start up screen does not appear automatically and the AutoPlay screen appears click Run startup exe to display the start up screen la hy i eea DVD CD RW Drive D YSS1000 F Always do this for software
14. AUTION The exclusive cable is not waterproof Do not use it in locations that are likely to be exposed to splashes of water or other liquids Ethernet communication Optional code A34 is necessary for the YS1000 Specification IEEE802 3 compliant 1OBASE T 100BASE TX RJ45 connector For a connection via a hub Straight cable For a direct connection Cross cable RS 485 communication Optional code A31 is necessary for the YS1000 Specification EIA RS 485 compliant IM 01B08K02 01EN 11 aunjaping Burjpuey Go e 5 o o Es te m gt lt O 3 Fo 3 Ca Installing USB Converter Driver Software CAUTION e Install USB converter driver software as an administrator e Avoid entering just the drive as the installation location such as CA Enter the full directory path Before installing USB converter driver software quit all running applications When reinstalling USB converter driver software uninstall the installed USB converter driver software first and then reinstall USB converter driver software Installing USB Converter Driver Software Operating procedures Start Windows 2 Insert the CD of YSS1000 into the CD ROM drive The start up screen appears automatically n a me MSIDDI series If you use the USB interface install the USB driver on your PC YOKOGAWA For details refer to the installation manual Note Ifthe start up screen does not appear automatically
15. AWA USB Serial Converter A1053UR 16 IM 01B08K02 01EN Installing USB Converter Driver Software 4 The COM port number assigned to the dedicated cable can be verified by the port number displayed in 1 YOKOGAWA USB Serial Port COMn of Device Manager see the step 3 To change the COM port number doubleclick 1 select Port Settings tab of Properties screen and click Advanced Change the COM port number in the Advanced Settings for COMn screen YOKOGAWA USB Serial Port COM3 Properties eax General Port Settings Driver Detais Bits per second 0 NA Databis fe SCS Party None i SS Stop bits hooo y Flow control None paa Uninstalling USB Converter Driver Software Operating procedures A CAUTION Unplug the dedicated cable if it is connected to a personal computer 7 Unplug the exclusive cable if it is connected to a personal computer 2 From the Start menu of Windows select Control Panel gt Programs and Features Note From the Start menu of Windows select Control Panel gt Uninstall a program if the control panel s display method is Control Panel Home 3 Select YOKOGAWA A1053UR Installer and click Uninstall 4 The User Account Control screen appears Click Continue 5 The Confirm Uninstall screen appears Click Yes YOKOGAWA A1053UR Installer InstallShield Wizard S S a S g 3 5 se G 85 a PINO aS o
16. Driver SOMWA NA a aaa ANG NG GG ad 17 Installing YSS1000 Setting Software 222220000000 amma amma naa NDN KN KNANG KN SAANN NA ANSENNNASKANSAASEANNNAENANAN NAA NNAN NANANA 18 Installing YSS1000 Setting SONWAaN AAA 18 Verifying INSA ui AN ka UN Kha ANAN NANG aa aaa 20 UhinstallingYSS1000 5S Hung Wan AA WAIUA KA AA 20 IM 01B08K02 01EN Foreword Thank you for purchasing the YSS1000 Setting Software hereinafter referred to as YSS1000 This manual describes the operating environment installation uninstallation Please read though this user s manual carefully before using the product For the function and operating method of YSS1000 Setting Software see YSS1000 Setting Software YS1700 Programmable Function User s Manual Note that the manuals for the YSS1000 comprise the following ten documents ePrinted manual Manual Number IM 01B08K02 01EN Manual Name YSS1000 Installation Manual This manual describes how to install uninstall the YSS1000 eElectronic manuals Manual Number IM 01B08B02 01EN Manual Name YS1500 YS1700 Operation Guide This manual describes the basic operation methods YS1500 YS1700 User s Manual IM 01B08B02 02EN This manual describes the detailed functions and setting items It does not contain the user programs and communication functions YS1310 Operation Guide IM 01B08D02 01EN This manual describes the basic operation methods YS1310 User s
17. YOKOGAWA MIDDLE EAST amp AFRICA B S C C P O Box 10070 Manama Building 577 Road 2516 Busaiteen 225 Muharraq BAHRAIN Phone 973 17 358100 Fax 973 17 336100 Apr 14
18. d in Article 12 hereof either party gives thirty 30 days prior written notice to the other party or you cease using the Package Software Product by itself 10 Injunction for Use During the term of this Agreement Yokogawa may at its own discretion demand an injunction against you and your customer in case Yokogawa deems the Package Software Product is used improperly or under severer environments than those Yokogawa first granted or any other condition which Yokogawa may not permit IM 01B08K02 01EN 7 License Agreement for Package Software Product 11 Confidentiality Obligation 1 You agree that the structure organization and code of the Package Software Product are the valuable trade secrets of Yokogawa or third party which grants Yokogawa the rights and the Package Software Product contains other proprietary information and know how of Yokogawa and its third party which may be disclosed for the purpose of license granted hereunder You shall not divulge any of such trade secrets information and know how to any third party without Yokogawa s consent and shall not use for any purpose other than license use 2 You shall maintain the Package Software Product its media any printing material and any copy thereof in strict confidence and with utmost care to comply with the said secrecy obligation and protect the right of Yokogawa and third party which grants Yokogawa the rights 12 Termination by Cause Yokogawa may immediately termi
19. e design of a process or line using the system controlled by the product or the product itself and or the design and installation of other protective and safety circuits are to be appropriately implemented as the customer deems necessary Be sure to use the spare parts approved by YOKOGAWA when replacing parts or consumables e This product is not designed or manufactured to be used in critical applications that directly affect or threaten human lives Such applications include nuclear power equipment devices using radioactivity railway facilities aviation equipment air navigation facilities aviation facilities and medical equipment If so used it is the user s responsibility to include in the system additional equipment and devices that ensure personnel safety e Modification of the product is strictly prohibited WARNING e Power Supply Ensure that the instrument s supply voltage matches the voltage of the power supply before turning ON the power e Protective Grounding To prevent electric shock always confirm that protective grounding is connected before turning ON the instrument s power supply e Necessity of Protective Grounding Do not cut off the internal or external protective grounding wire or disconnect the wiring of the protective grounding terminal Doing so renders the protective functions of the instrument invalid and poses a potential shock hazard e Defects in Protective Functions If protective functions such as
20. fter use It can become deformed or damaged unless it is kept in its case Note Please store your original CDs carefully Install the program on your hard disk and run it from your hard disk during actual use 10 IM 01B08K02 01EN Operating Environment PC OS Windows 7 Professional 32bit 64bit Windows 8 1 Pro 32 bit 64 bit versions for Desktop CPU Pentium4 processor 3 0GHz or higher or Core2Duo Processor 1 8GHz or higher recommended Main memory capacity 2GB or more Free hard disk space 100MB or more Browser Internet Explorer 5 01 or later Display 1024 x 768 pixels or more Font Small font Color 256 or more colors COM port For USB communication USB port 1channel For RS 485 communication RS 232C port 1 channel For Ethernet communication 10BASE T 100BASE TX RJ45 connector CD ROM Drive One required for installation Printer Paper size Letter or A4 required for printing USB communication The USB port on a PC and the communication port inside the front panel of the YS1000 can to be connected with an exclusive cable EMC Standards EN61326 1 Class A Table 2 For use in industrial location EN55011 Class A Group 1 KC marking Electromagnetic wave interference prevention standard electromagnetic wave protection standard compliance EMC Regulatory Arrangement in Australia and New Zealand EN55011 compliant Class A Group 1 WEEE Directive Compliant PC specification USB1 1 Cc AQ a C
21. g Article 7 1 Provided however that Yokogawa shall have no liability for any claim of infringement in the preceding Article 7 1 if based on a use of other than the latest version of Package Software Product made available to you if the infringement would have been avoided by use of such version b addition to Package Software Product of any other software or program not advised or recommended by Yokogawa if the infringement would have been avoided without such addition c the combination or use of Package Software Product with software or program not furnished by Yokogawa if such infringement would have been avoided by use of Package Software Product with Yokogawa software or program alone or any other cause not within the control of Yokogawa 3 When any assertion of the infringement of third party s right defined in Article 7 1 is made or when at Yokogawa s judgment there is possibility of such assertion Yokogawa will at its discretion and not obligation take any of the following countermeasures at Yokogawa s cost and expense a To acquire the necessary right from a third party which has lawful ownership of the right so that you will be able to continue to use the Package Software Product b To replace the Package Software Product with the one which avoids the infringement c To remodel the Package Software Product so that the Package Software Products can avoid the infringement of such third party s right or d If and when
22. g display Perform the operations in chronological order This section describes the procedure under the assumption that these steps are being taken for the first time There are cases where not all of the steps are required depending on the required operation Setting Details Provides the descriptions of settings Describes restrictions etc regarding a relevant operation About an Electronic Manual User s manuals for YS1000 are available on the following web site www yokogawa com ns ys im You need Adobe Reader 7 0 or later but the latest version is recommended installed on the computer in order to open and read the manuals 4 IM 01B08K02 01EN SS MM No VS IM 01B08K02 01EN 5 License Agreement for Package Software Product ATTENTION Please read this LICENSE AGREEMENT hereinafter referred to as the Agreement carefully before installing this package software product of Yokogawa Electric Corporation hereinafter referred to as Yokogawa on the computer Installing this package software product indicates your acceptance of the terms and conditions of this Agreement If you are not the end user transferring this package software product indicates your acceptance of the terms and conditions of this Agreement and you are required to cause the transferee agree to and observe the terms and conditions of this Agreement If you don t accept the terms and conditions of this Agreement please kindly return this
23. implied with respect to the software s merchantability or suitability for any particular purpose except as specified in the terms of the separately provided warranty This software may be used on one specific machine only To use the software on another machine the software must be purchased again separately Itis strictly prohibited to reproduce the product except for backup purposes Store the software CD ROM the original medium in a safe place All reverse engineering operations such as reverse compilation or the reverse assembly of the product are strictly prohibited No part of the product s software may be transferred converted or sublet for use by any third party without prior written consent from YOKOGAWA Handling Precautions for the Main Unit The instrument comprises many plastic components To clean it wipe it with a soft dry cloth Do not use organic solvents such as benzene or thinner for cleaning as discoloration or deformation may result Keep electrically charged objects away from the signal terminals Not doing so may cause the instrument to fail Do not apply volatile chemicals to the display area operation keys etc Do not leave the instrument in contact with rubber or PVC products for extended periods Doing so may result in failure Ifthe equipment emits smoke or abnormal smells or makes unusual noises turn OFF the instrument s power switch immediately and unplug the device In
24. in the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Would you like to install this device software Name YOKOGAWA USB Serial Converter A1053UR I Publisher Yokogawa Electric Corporation Always trust software from Yokogawa Electric Corporation You should only install driver software from publishers you trust How can I decide which device software is safe to install Would you like to install this device software Name YOKOGAWA USB Serial Port Driver lt Publisher Yokogawa Electric Corporation Always trust software from Yokogawa Electric instal Don t Install Corporation You should only install driver software from publishers you trust How can I decide which device software is safe to install 14 IM 01B08K02 01EN Installing USB Converter Driver Software 9 When installation is complete the Finish dialog box appears Click Finish YOKOGAWA A1053UR Installer InstallShield Wizard InstallShield Wizard Complete The InstallShield Wizard has successfully installed YOKOGAWA 41053UR Installer Click Finish to exit the wizard Cancel The dialog box closes You have completed installing the driver software When you connect the dedicated cable to a USB port on your computer the driver becomes available automatically SI D a US 5 se IG NG Fo aS 02
25. ing of the same at the site by Yokogawa or any person designated by Yokogawa is needed such cost and expense for the works shall be borne by you and you shall initialize or shut down the system and other related system products or equipment if deemed necessary at Yokogawa s sole judgment IM 01B08K02 01EN License Agreement for Package Software Product 3 Notwithstanding the preceding Article 4 2 Yokogawa s warranty shall not apply if the defect of the Package Software Product is caused by any of the followings a where hardware on which the Package Software Product operates becomes out of warranty of the vendor and proper maintenance contract for the hardware is not in place b where if Yokogawa designates hardware on which the Package Software Product operates you changed such hardware to other hardware without Yokogawa s consent c where any third party other than entrusted by Yokogawa conducted renovation or improvement of the Package Software Product d where hardware on which the Package Software Product operates was moved by you or any third party without Yokogawa s consent e where you or a party you designate including your customer misused renovated up graded or used the Package Software Product for any other purpose than set forth in the Instruction Manuals etc Joj juawadby asuadi7 f where the Package Software Product was used or operated under the different operating environment and or other co
26. nate this Agreement without any notice or demand to you if you breach any of the terms and conditions of this Agreement However Articles 2 4 2 6 2 8 7 8 11 and 12 shall survive even after the termination 13 Governing Law and Arbitration 1 This Agreement shall be governed by and construed in accordance with the laws of Japan 2 All disputes controversies or differences which may arise between the parties hereto out of or in relation to or in connection with this Agreement shall be finally settled by arbitration in Tokyo Japan in accordance with the Commercial Arbitration Rules of the Japan Commercial Arbitration Association The arbitration is conducted in the Japanese language The award rendered by the arbitrator s shall be final and binding upon the parties hereto 8 IM 01B08K02 01EN Checking the Contents of the Package Unpack the box and check the contents before using the product If the product is different from that which you have ordered if any parts or items are missing or if the product appears to be damaged contact your sales representative YSS1000 Setting Software Check the model and suffix codes to confirm that the product received is that which was ordered yonpoig aiemyos abeyoeg Jo Juawadiby asuadi7 Model and Suffix Codes YSS1000 Setting Software for YS1000 Series 0 Always 0 0 Always 0 CD media with exclusive cable included Package Contents The f
27. nditions than the terms designated by Yokogawa or provider of hardware g where you or your customer does not execute the proper trouble or non conformity avoiding measures including repair or replacement Yokogawa proposed or other cause of defect not attributable to Yokogawa 4 The Warranty Period shall be the twelve 12 month period from the date when Yokogawa complete the delivery at the place designated by you including your customer V o 2 9 te N oi r pi o BO Fe 2 c o om or you or your customer use part or whole of the Package Software Product for the operation whichever comes first unless otherwise agreed in writing by Yokogawa 5 Under separate maintenance contract Yokogawa may conduct maintenance service for the Package Software Product at the expense of you even after the Warranty period The maintenance service for the Package Software Product shall be classified into those of standard software customized software a Standard Software Standard Software herein means the standard package software covered by Yokogawa s Catalogue and or General Specifications The maintenance service for Standard Software may be available for the latest two versions unless otherwise covered by Yokogawa s Catalogue and or General Specifications However the maintenance service for the Package Software Product which is the earlier version among the latest two versions may be available only for five 5 years after the last
28. o your end user and cause your end user to observe such terms and conditions If Yokogawa incurs damage due to your end user s breach of such terms and conditions as set forth herein you shall indemnify and hold Yokogawa harmless as set forth herein above In this case it is the end user that is granted the license of the Package Software Product by Yokogawa and if you are not the end user you shall transfer the possession of media and related materials of the Package Software Product to your end user 7 Intellectual Property Infringement 1 If and when any third party should demand injunction initiate a law suit or demand damages against you under patent right utility model right design patent right trademark right copyright and or any other right relating to any of the Package Software Product including but not limited to its related materials you shall notify Yokogawa of that effect in writing without delay 2 In case of preceding Article 7 1 you shall assign to Yokogawa all of the rights to defend you to negotiate and to settle with the claiming party Furthermore you shall provide Yokogawa with necessary information or any other assistance for Yokogawa s defense and negotiation If and when such a claim should be attributable to Yokogawa Yokogawa shall defend you and negotiate with the claiming party at Yokogawa s cost and expense and be responsible for the final settlement or judgment granted to the claiming party in the precedin
29. ollowing items are provided Check that none of them are missing or damaged abeyorg ay 2 r O 3 te ch 3 2 3 oh D 5 ch Z fe mo Product Name Pareno ay Rems 1 Setting Software L4041WA 1 Installation CD Exclusive cable for YS1000 connection A1053UR 1 USB 1 1 3 YSS1000 Installation Manual this manual 1 A4 size IM 01B08K02 01EN 9 CD Handling Guideline Make sure to take the following precautions CAUTION Do not store the product near large amounts of refuse or dust e Do not touch the surface of the CD with no printed characters Dirt or sweat from fingertips can damage the CD Do not write anything on the CD e Pencil lead or residue from erasers can damage the CD Do not bend or scratch the CD Doing so can cause it to become unreadable Never place anything on top of the CD Doing so can cause deformities that can render the CD useless Do not drop the CD from high locations as doing so can cause damage or deformities Do not place the CD in direct sunlight or near heat sources e Never allow solvents such as alcohol benzene or Freon to come into contact with the CD Take care when placing the CD into the CD ROM drive e While the CD is being accessed do not remove the CD from the CD ROM drive cut the power to the PC or reset the computer e Store the CD in its original jewel case Do not leave the CD in the CD ROM drive a
30. oshima Kurashiki Fukuoka Kitakyusyu YOKOGAWA CORPORATION OF AMERICA Head Office 12530 West Airport Blvd Sugar Land Texas 77478 USA Phone 1 281 340 3800 Fax 1 281 340 3838 Georgia Office 2 Dart Road Newnan Georgia 30265 USA Phone 1 800 888 6400 1 770 253 7000 Fax 1 770 254 0928 YOKOGAWA AMERICA DO SUL LTDA Praca Acapulco 31 Santo Amaro Sao Paulo SP BRAZIL CEP 04675 190 Phone 55 11 5681 2400 Fax 55 11 5681 4434 YOKOGAWA EUROPE B V Euroweg 2 3825 HD Amersfoort THE NETHERLANDS Phone 31 88 4641000 Fax 31 88 4641111 YOKOGAWA ELECTRIC CIS LTD Grokholskiy per 13 Building 2 4th Floor 129090 Moscow RUSSIA Phone 7 495 737 7868 Fax 7 495 737 7869 YOKOGAWA CHINA CO LTD 3F Tower D Cartelo Crocodile Building No 568 West Tianshan Road Shanghai 200335 CHINA Phone 86 21 62396262 Fax 86 21 62387866 YOKOGAWA ELECTRIC KOREA CO LTD Yokogawa B D Yangpyeong dong 4 Ga 21 Seonyu ro 45 gil Yeongdeungpo gu Seoul 150 866 KOREA Phone 82 2 2628 6000 Fax 82 2 2628 6400 YOKOGAWA ENGINEERING ASIA PTE LTD 5 Bedok South Road Singapore 469270 SINGAPORE Phone 65 6241 9933 Fax 65 6241 2606 YOKOGAWA INDIA LTD Plot No 96 Electronic City Complex Hosur Road Bangalore 560 100 INDIA Phone 91 80 4158 6000 Fax 91 80 2852 1442 YOKOGAWA AUSTRALIA PTY LTD Tower A 112 118 Talavera Road Macquarie Park NSW 2113 AUSTRALIA Phone 61 2 8870 1100 Fax 61 2 8870 1111
31. ovements to the instrument s performance and functions e Every effort has been made to ensure accuracy in the preparation of this manual Should any errors or omissions come to your attention however please inform YOKOGAWA Electric s sales office or sales representative e Under no circumstances may the contents of this manual in part or in whole be transcribed or copied without our permission Trademarks e Our product names or brand names mentioned in this manual are the trademarks or registered trademarks of YOKOGAWA Electric Corporation hereinafter referred to as YOKOGAWA e Microsoft Windows Windows 7 and Windows 8 1 are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries e Adobe Acrobat and Postscript are either registered trademarks or trademarks of Adobe Systems Incorporated e Ethernet is a registered trademark of XEROX Corporation e We do not use the TM or mark to indicate these trademarks or registered trademarks in this user s manual e All other product names mentioned in this user s manual are trademarks or registered trademarks of their respective companies Revisions 1st Edition June 2014 2nd Edition July 2014 E Notes on the User s Manual e This user s manual should be readily accessible to the end users so it can be referred to easily It should be kept in a safe place Read the information contained in this manual thoroughly befo
32. re operating the product The purpose of this user s manual is not to warrant that the product is well suited to any particular purpose but rather to describe the functional details of the product m Safety Protection and Modification of the Product The following symbols are used in the product and user s manuals to indicate safety precautions Handle with Care This symbol is attached to the part s of the product to indicate that the user s manual should be referred to in order to protect the operator and the instrument from harm Protective grounding terminal Functional grounding terminal Do not use this terminal as a protective grounding terminal Alternating current Direct current In order to protect the system controlled by this product and the product itself and to ensure safe operation observe the safety precautions described in this user s manual Use of the instrument in a manner not prescribed herein may compromise the product s functions and the protection features inherent in the device We assume no liability for safety or responsibility for the product s quality performance or functionality should users fail to observe these instructions when operating the product 2 IM 01B08K02 01EN e Installation of protection and or safety circuits with respect to a lightning protector protective equipment for the system controlled by the product and the product itself foolproof or failsaf
33. roduct and the all copy and duplicates thereof shall be returned to Yokogawa or the party designated by Yokogawa immediately after the expiration or termination of this Agreement Alternatively if Yokogawa requires in writing to you that all the Package Software Product is destroyed or disposed all the information therein shall be deleted completely 9 The Package Software Product may include software program of a third party hereinafter called Third Party Software which may include any software program made and provided by Yokogawa s affiliate granting Yokogawa the right to sublicense In the case the different terms and conditions from this Agreement shall apply to Yokogawa s sublicense of such Third Party Software you shall observe such terms and conditions of which Yokogawa notifies you in writing separately 10 You shall not subject the Package Software Product in whole or in part to any license obligations associated with Open Source Software Open source Software means any software that requires as a condition of use modification or distribution of such software i be disclosed or distributed in source code form or ii be licensed by the user to third parties for the purpose of making or distributing derivative works or iii be distributed at no charge Open Source Software includes without limitation software licensed or distributed under any of the following licenses or distribution models or licenses or distribution
34. twork and wide area network 3 The Package Software Product shall not be copied in whole or in part except keeping one copy for back up purpose unless otherwise agreed in writing by Yokogawa in advance You shall store and manage the copy or duplicate of the Package Software Product in strict confidence and with utmost care 4 You shall not and shall not have any third party including the end user alter decompile disassemble decrypt extract or otherwise reverse engineer the Package Software Product or create any derivative works thereof Unless otherwise separately agreed by Yokogawa Yokogawa has no obligation to provide you with the source code for the Package Software Product 5 The Package Software Product including all proprietary technology algorithm and know how such as a factor invariant or process contained therein shall be the proprietary property or trade secret of Yokogawa or a third party which grants Yokogawa the rights 6 The proprietary property and or trade secret as defined in the preceding Article 2 5 shall not be published or disclosed to any third parties except for your limited employees or equivalents thereto who need to have access thereto You are also required to impose no less stringent confidentiality obligation than herein on them 7 Yokogawa may use or add copy protection in or to the Package Software Product In no event shall you remove or attempt to remove such copy protection 8 The Package Software P
35. up dated The maintenance service for the Package Software Product declared by Yokogawa to discontinue order acceptance may be available for five 5 years after such declaration b Customized Software Customized Software herein means the software customized by Yokogawa pursuant to the Quotation or Functional Specifications agreed by both parties The maintenance service for the Customized Software shall not be available to you including your customer after the Warranty Period unless otherwise separately agreed by both parties However such maintenance service may be conducted at your expense as remodeling contract agreed by the both parties 6 Notwithstanding the preceding Article 4 1 4 2 4 3 4 4 and 4 5 on the third party s software warranty including warranty period of such third party provider shall apply 5 Revision Up Package Software When you receive the revision up of the Package Software Product which is substituted for or is added to the Package Software Product Revision Up you can install such Revision Up in the computer s on which you use the Package Software Product Furthermore the Revision Up shall be considered as the Package Software Product and you shall agree to comply with the terms and conditions of this Agreement in order to use the Revision Up 6 If You are not the End User If you are not the end user of the Package Software Product you shall present the terms and conditions of this Agreement t

Download Pdf Manuals

image

Related Search

Related Contents

Model 3012 Mobile Data Terminal  USER MANUAL - eStore.com.au  Tanaka TBC-220 User's Manual    Ultraschallsystem-Benutzerhandbuch  Introduction to Python for Science The workflow: IPython and a text  Da-Lite 91843 projection screen  Source to Camera Distance for Diverging Beams  Manual de instrucciones Sistema de soldadura MIG FP-120, FP    

Copyright © All rights reserved.
Failed to retrieve file